Next Article in Journal
Influence of Trust on Biomass Supply Decision-Making in China
Previous Article in Journal
Decomposed Driving Factors of Carbon Emissions and Scenario Analyses of Low-Carbon Transformation in 2020 and 2030 for Zhejiang Province
Previous Article in Special Issue
An Analysis of Different Solar-Assisted Heating Systems and Their Effect on the Energy Performance of Multifamily Buildings—A Swedish Case
Article Menu
Issue 11 (November) cover image

Export Article

Open AccessArticle
Energies 2017, 10(11), 1746; doi:10.3390/en10111746

Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature

College of Mechanical and Electrical Engineering, Northeast Forestry University, Harbin 150000, China
*
Author to whom correspondence should be addressed.
Received: 6 September 2017 / Revised: 15 October 2017 / Accepted: 25 October 2017 / Published: 31 October 2017
(This article belongs to the Special Issue Solar-Assisted Heat Pump Systems for Heating and Cooling)

Abstract

Solar-driven ammonia-water absorption refrigeration system (AARS) has been considered as an alternative for the conventional refrigeration and air-conditioning systems. However, its high initial cost seems to be the main problem that postpones its wide spread use. In the present study, a single-stage NH3/H2O ARS is analyzed in depth on the basis of energetic and exergetic coefficients of performance (COP and ECOP, respectively) to decrease its cut in/off temperature. This study was carried out to lower the required heat source temperature, so that a less-expensive solar collector could be used. Effects of all parameters that could influence the system’s performance and cut in/off temperature were investigated in detail. Presence of water in the refrigerant and evaporator temperature glide was considered. Results revealed that appropriate selection of system’s working condition can effectively reduce the driving temperature. Besides, the cut in/off temperature can be significantly decreased by inserting an effective solution heat exchanger (SHX). Required driving temperature can be lowered by up to 10 °C using SHX with 0.80 effectiveness. The results also showed that effects of water content in the refrigerant could not be neglected in studying NH3/H2O ARS because it affects both COP and ECOP. Additionally, a large temperature glide in the evaporator can substantially decrease the ECOP. View Full-Text
Keywords: solar assisted cooling; heat pumps; solar thermal systems; absorption refrigeration solar assisted cooling; heat pumps; solar thermal systems; absorption refrigeration
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Wageiallah Mohammed, O.; Yanling, G. Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature. Energies 2017, 10, 1746.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Energies EISSN 1996-1073 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top