Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (90)

Search Parameters:
Keywords = wrist pulse

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 1071 KiB  
Article
Noninvasive Analysis of Biological Components Using Simplified Mid-Infrared Photothermal Deflection Spectroscopy
by Hiroto Ito, Saiko Kino and Yuji Matsuura
Sensors 2025, 25(14), 4368; https://doi.org/10.3390/s25144368 - 12 Jul 2025
Viewed by 255
Abstract
We developed a photothermal deflection spectroscopy (PTDS) system for the noninvasive analysis of biological tissue. This system detects heat induced by irradiation with pulse-modulated mid-infrared light as the deflection of a probe laser. The probe light is incident on the sensing element horizontal [...] Read more.
We developed a photothermal deflection spectroscopy (PTDS) system for the noninvasive analysis of biological tissue. This system detects heat induced by irradiation with pulse-modulated mid-infrared light as the deflection of a probe laser. The probe light is incident on the sensing element horizontal with respect to its contact surface with the sample. This setup simplifies the optical alignment compared to conventional systems, which require the probe laser to be totally reflected at the prism contact surface and aligned with the point of mid-infrared light irradiation. In this study, we measured the PTDS spectra of biological samples to determine the characteristic features of their infrared absorption. We also compared the measurement reproducibility of two configurations: a horizontal optical path and a total reflection optical path. The horizontal optical path showed greater measurement reproducibility than the total reflection optical path when performing intermittent measurements on the wrist. Full article
(This article belongs to the Special Issue Advanced Non-Invasive Sensors: Methods and Applications—2nd Edition)
Show Figures

Figure 1

18 pages, 6821 KiB  
Article
Strain Plethysmography Using a Hermetically Sealed MEMS Strain Sensor
by Xinyu Jiang, Brian Sang, Haoran Wen, Gregory Junek, Jin-Woo Park and Farrokh Ayazi
Biosensors 2025, 15(5), 325; https://doi.org/10.3390/bios15050325 - 20 May 2025
Viewed by 2534
Abstract
We present a hermetically sealed capacitive microelectromechanical system (MEMS) strain sensor designed for arterial pulse waveform extraction using the strain plethysmography (SPG) modality. The MEMS strain sensor features a small form factor of 3.3 mm × 3.3 mm × 1 mm, leverages a [...] Read more.
We present a hermetically sealed capacitive microelectromechanical system (MEMS) strain sensor designed for arterial pulse waveform extraction using the strain plethysmography (SPG) modality. The MEMS strain sensor features a small form factor of 3.3 mm × 3.3 mm × 1 mm, leverages a nano-gap fabrication process to improve the sensitivity, and uses a differential sensing mechanism to improve the linearity and remove the common mode drift. The MEMS strain sensor is interfaced with an application-specific integrated circuit (ASIC) to form a compact strain sensing system. This system exhibits a high strain sensitivity of 316 aF/µε, a gauge factor (GF) of 35, and a strain sensing resolution of 1.26 µε, while maintaining a linear range exceeding 700 µε. SPG signals have been reliably captured at both the fingertip and wrist using the MEMS strain sensor with high signal quality, preserving various photoplethysmography (PPG) features. Experimental results demonstrate that heart rate (HR) and heart rate variability (HRV) can be estimated from the SPG signal collected at the fingertip and wrist using the sensor with an accuracy of over 99%. Pulse arrival time (PAT) and pulse transit time (PTT) have been successfully extracted using the sensor together with a MEMS seismometer, showcasing its potential for ambulatory BP monitoring (ABPM) application. Full article
(This article belongs to the Special Issue Biosensors for Monitoring and Diagnostics)
Show Figures

Figure 1

13 pages, 2387 KiB  
Article
WATCH-PR: Comparison of the Pulse Rate of a WATCH-Type Blood Pressure Monitor with the Pulse Rate of a Conventional Ambulatory Blood Pressure Monitor
by Mathini Vaseekaran, Marcus Wiemer, Sven Kaese, Dennis Görlich, Jochen Hinkelbein, Gerrit Jansen and Alexander Samol
Bioengineering 2025, 12(5), 492; https://doi.org/10.3390/bioengineering12050492 - 5 May 2025
Cited by 1 | Viewed by 689
Abstract
Background: Monitoring pulse rate is fundamental to cardiovascular health management and early detection of rhythm disturbances. While oscillometric blood pressure measurement is well established and validated in clinical practice, its use for pulse rate monitoring, particularly via wrist-worn devices, remains largely unexplored. Objective: [...] Read more.
Background: Monitoring pulse rate is fundamental to cardiovascular health management and early detection of rhythm disturbances. While oscillometric blood pressure measurement is well established and validated in clinical practice, its use for pulse rate monitoring, particularly via wrist-worn devices, remains largely unexplored. Objective: This study investigates whether a smartwatch that performs oscillometric blood pressure measurements at the wrist can also deliver reliable pulse rate readings using the same method. Methods: This study compared pulse rates recorded by the Omron HeartGuide smartwatch and conventional ambulatory blood pressure monitors in 50 patients over 24 h. Measurements were taken consecutively, and data were analyzed using intraclass correlation coefficients (ICCs) and Bland–Altman plots. Results: The study showed a high ICC of 0.971, indicating excellent agreement between devices. The average pulse rate difference was 1.5 bpm, with the Omron HeartGuide reporting slightly lower rates, especially in patients with atrial fibrillation. Conclusions: This study demonstrates that oscillometric pulse-rate monitoring at the wrist can achieve a high degree of accuracy, comparable to conventional upper-arm devices. Given that oscillometric smartwatches like the Omron HeartGuide are already used for blood pressure monitoring, the findings suggest that they may also be suitable for pulse rate measurement, potentially enhancing their role in telemetric healthcare, but further research is needed, particularly in patients with arrhythmias. Full article
Show Figures

Figure 1

14 pages, 3224 KiB  
Article
Blood Pressure and Heart Rate Measurements Using Fiber Bragg Grating Sensor with Optical Power Detection Scheme
by Yu-Jie Wang and Likarn Wang
Sensors 2025, 25(7), 2007; https://doi.org/10.3390/s25072007 - 23 Mar 2025
Cited by 2 | Viewed by 658
Abstract
A low-cost dual-FBG (fiber Bragg grating) architecture is employed to capture the pulse waveform of the artery at the subject’s wrist by measuring changes in optical power. The pulse transit time (PTT), pulse ascending time, and pulse descending time extracted from the pulse [...] Read more.
A low-cost dual-FBG (fiber Bragg grating) architecture is employed to capture the pulse waveform of the artery at the subject’s wrist by measuring changes in optical power. The pulse transit time (PTT), pulse ascending time, and pulse descending time extracted from the pulse waveform are used in a blood pressure (BP) estimation model by fitting the measured BP with the reference BP obtained from a commercial sphygmomanometer. The estimation model is developed using data from 29 subjects at the age of 20 to 54. The results demonstrate that the errors between the calculated values and reference values of SBP and DBP for all of the 29 subjects both range from −4 to 5 mmHg with mean errors of 0.72 mmHg and 0.83 mmHg, respectively. The standard error can be found to be 2.45 and 2.59 mmHg for SBP and DBP, respectively. Also, it is found that this BP estimation model outperforms two BP models derived by considering PTT only. Full article
(This article belongs to the Special Issue Advanced Fiber Optic Lasers and Sensors)
Show Figures

Figure 1

16 pages, 2227 KiB  
Article
Emotion Recognition Using a Siamese Model and a Late Fusion-Based Multimodal Method in the WESAD Dataset with Hardware Accelerators
by Hyun-Sik Choi
Electronics 2025, 14(4), 723; https://doi.org/10.3390/electronics14040723 - 13 Feb 2025
Cited by 3 | Viewed by 1420
Abstract
Emotion recognition, which includes stress analysis, is a critical research topic. In particular, emotion recognition using wearable applications that offer rapid feedback can significantly assist in emotion regulation. A key dataset for this purpose is the wearable stress and affect detection (WESAD) dataset, [...] Read more.
Emotion recognition, which includes stress analysis, is a critical research topic. In particular, emotion recognition using wearable applications that offer rapid feedback can significantly assist in emotion regulation. A key dataset for this purpose is the wearable stress and affect detection (WESAD) dataset, which is well-suited for wearable environments. This study aims to evaluate the accuracy and processing time of the proposed neural network using the WESAD dataset. However, data collected in wearable environments often have limitations in terms of their accuracy and channel count, making classification challenging. To address this issue, this study utilizes only wrist-measured blood volume pulse (BVP) data measured by photo-plethysmography (PPG) and electro-dermal activity (EDA) data, classifying them through a late fusion-based multimodal method. For accurate classification, the BVP data are preprocessed using the empirical mode decomposition (EMD) method, and a Siamese model is employed for learning on small datasets, with an additional structure of dense layers for detailed classification. The Siamese network generates a similarity score, which is then fed into a dense layer to classify multiple classes. Meta-classes are used to compute pairwise similarities, ultimately classifying the data into one of four emotional states: neutral, stress, amusement, and meditation. The proposed multitasking model simultaneously trains the Siamese network and multi-classifier, achieving an accuracy of 99.8% in classifying four emotion states in the WESAD dataset. Moreover, the model is designed to operate with minimal hardware resources, making it easy to implement using hardware accelerators. This study demonstrates the applicability of neural network-based wearable systems in the field of emotion recognition. Full article
(This article belongs to the Section Artificial Intelligence)
Show Figures

Figure 1

22 pages, 2339 KiB  
Article
Signal Acquisition and Algorithm Design for Bioimpedance-Based Heart Rate Estimation from the Wrist
by Didzis Lapsa, Margus Metshein, Andrei Krivošei, Rims Janeliukstis, Olev Märtens and Atis Elsts
Appl. Sci. 2024, 14(21), 9632; https://doi.org/10.3390/app14219632 - 22 Oct 2024
Cited by 1 | Viewed by 1853
Abstract
Background: Heart rate (HR) is a critical biomarker that provides insights into overall health, stress levels, and the autonomic nervous system. Pulse wave signals contain valuable information about the cardiovascular system and heart status. However, signal acquisition in wearables poses challenges, particularly when [...] Read more.
Background: Heart rate (HR) is a critical biomarker that provides insights into overall health, stress levels, and the autonomic nervous system. Pulse wave signals contain valuable information about the cardiovascular system and heart status. However, signal acquisition in wearables poses challenges, particularly when using electrical sensors, due to factors like the distance from the heart, body movement, and suboptimal electrode placement. Methods: Electrical bioimpedance (EBI) measurements using bipolar and tetrapolar electrode systems were employed for pulse wave signal acquisition from the wrist in both perpendicular and distal configurations. Signal preprocessing techniques, including baseline removal via Hankel matrix methods, normalization, cross-correlation, and peak detection, were applied to improve signal quality. This study describes the combination of sensor-level signal acquisition and processing for accurate wearable HR estimation. Results: The bipolar system was shown to produce larger ΔZ(t), while the tetrapolar system demonstrated higher sensitivity. Distal placement of the electrodes yielded greater ΔZ(t) (up to 0.231 Ω) when targeting both wrist arteries. Bandpass filtering resulted in a better signal-to-noise ratio (SNR), achieving 3.6 dB for the best bipolar setup and 4.8 dB for the tetrapolar setup, compared to 2.6 and 3.3 dB SNR, respectively, with the Savitzky–Golay filter. The custom HR estimation algorithm presented in this paper demonstrated improved accuracy over a reference method, achieving an average error of 1.8 beats per minute for the best bipolar setup, with a mean absolute percentage error (MAPE) of 8%. Conclusions: The analysis supports the feasibility of using bipolar electrode setups on the wrist and highlights the importance of electrode positioning relative to the arteries. The proposed signal processing method, featuring a preprocessing pipeline and HR estimation algorithm, provides a proof-of-concept demonstration for HR estimation from EBI signals acquired at the wrist. Full article
(This article belongs to the Special Issue Robotics, IoT and AI Technologies in Bioengineering)
Show Figures

Figure 1

12 pages, 3631 KiB  
Article
Fiber Bragg Grating Pulse and Systolic Blood Pressure Measurement System Based on Mach–Zehnder Interferometer
by Yuanjun Li, Bo Wang, Shanren Liu, Mengmeng Gao, Qianhua Li, Chao Chen, Qi Guo and Yongsen Yu
Sensors 2024, 24(19), 6222; https://doi.org/10.3390/s24196222 - 26 Sep 2024
Cited by 1 | Viewed by 1641
Abstract
A fiber Bragg grating (FBG) pulse and systolic blood pressure (SBP) measurement system based on the edge-filtering method is proposed. The edge filter is the Mach–Zehnder interferometer (MZI) fabricated by two fiber couplers with a linear slope of 52.45 dBm/nm. The developed system [...] Read more.
A fiber Bragg grating (FBG) pulse and systolic blood pressure (SBP) measurement system based on the edge-filtering method is proposed. The edge filter is the Mach–Zehnder interferometer (MZI) fabricated by two fiber couplers with a linear slope of 52.45 dBm/nm. The developed system consists of a broadband light source, an edge filter, fiber Bragg gratings (FBGs), a coarse wavelength-division multiplexer (CWDM), and signal-processing circuits based on a field-programmable gate array (FPGA). It can simultaneously measure pulse pulsations of the radial artery in the wrist at three positions: Cun, Guan and Chi. The SBP can be calculated based on the pulse transit time (PTT) principle. The measurement results compared to a standard blood pressure monitor showed the mean absolute error (MAE) and standard deviation (STD) of the SBP were 0.93 ± 3.13 mmHg. The system meets the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) equipment standards. The proposed system can achieve continuous real-time measurement of pulse and SBP and has the advantages of fast detection speed, stable performance, and no compression sensation for subjects. The system has important application value in the fields of human health monitoring and medical device development. Full article
(This article belongs to the Section Optical Sensors)
Show Figures

Figure 1

15 pages, 1957 KiB  
Article
Distal Transradial Access Optimization: A Prospective Trial of Ultrasound-Guided Radial Artery Characterization for the Anatomical Snuffbox
by Łukasz Koziński, Zbigniew Orzałkiewicz, Paweł Zagożdżon and Alicja Dąbrowska-Kugacka
Diagnostics 2024, 14(18), 2081; https://doi.org/10.3390/diagnostics14182081 - 20 Sep 2024
Cited by 2 | Viewed by 2003
Abstract
Background/Objectives: The distal transradial approach (dTRA) is increasingly used in interventional cardiology. Doppler Ultrasound (DUS) effectively assesses radial artery (RA) characteristics. This study aims to identify specific RA DUS characteristics in patients undergoing coronary procedures via dTRA. Methods: Participants from the ANTARES [...] Read more.
Background/Objectives: The distal transradial approach (dTRA) is increasingly used in interventional cardiology. Doppler Ultrasound (DUS) effectively assesses radial artery (RA) characteristics. This study aims to identify specific RA DUS characteristics in patients undergoing coronary procedures via dTRA. Methods: Participants from the ANTARES trial who completed the intervention per-protocol and retained RA patency were included. DUS was performed at baseline, 1 day, and 60 days post-procedure. Results: Among 400 participants, 348 had either dTRA (n = 169) or conventional transradial access (cTRA) (n = 179). Distal RA lumen diameter was 12% smaller than that of the proximal RA (p < 0.001). Men had a 14% larger distal RA diameter than women (2.33 ± 0.31 mm vs. 2.04 ± 0.27 mm, p < 0.0001), similar to the proximal RA relationship. Peak flow velocities were similar between the sexes. Univariate linear regression showed that height, weight, body mass index, and body surface area (BSA) predicted arterial size, with BSA remaining significant in multivariate analysis (beta coefficient 0.62; confidence interval 0.49–0.75; p < 0.0001). Distal RA diameter correlated positively with palpable pulse at the snuffbox and wrist. The dTRA resulted in an immediate 14% and 11% increase in distal and proximal RA diameter, respectively (both p < 0.05). Sixty days after dTRA, the distal RA remained slightly dilated (p < 0.05), while the proximal RA returned to baseline. Conclusions: Distal RA diameter is significantly associated with sex, measuring smaller than the forearm segment. A strong palpable pulse correlates with larger distal RA size. The dTRA induces RA lumen expansion. A thorough understanding of distal RA anatomy is essential for optimizing patient selection and refining techniques for transradial procedures. Full article
(This article belongs to the Special Issue New Trends and Advances in Cardiac Imaging)
Show Figures

Graphical abstract

19 pages, 4413 KiB  
Article
Development of Highly Flexible Piezoelectric PVDF-TRFE/Reduced Graphene Oxide Doped Electrospun Nano-Fibers for Self-Powered Pressure Sensor
by Arsalan Ahmed, Nazakat Ali Khoso, Muhammad Fahad Arain, Imran Ahmad Khan, Kashif Javed, Asfandyar Khan, Sanam Irum Memon, Qinguo Fan and Jianzhong Shao
Polymers 2024, 16(13), 1781; https://doi.org/10.3390/polym16131781 - 24 Jun 2024
Cited by 6 | Viewed by 2984
Abstract
The demand for self-powered, flexible, and wearable electronic devices has been increasing in recent years for physiological and biomedical applications in real-time detection due to their higher flexibility and stretchability. This work fabricated a highly sensitive, self-powered wearable microdevice with Poly-Vinylidene Fluoride-Tetra Fluoroethylene [...] Read more.
The demand for self-powered, flexible, and wearable electronic devices has been increasing in recent years for physiological and biomedical applications in real-time detection due to their higher flexibility and stretchability. This work fabricated a highly sensitive, self-powered wearable microdevice with Poly-Vinylidene Fluoride-Tetra Fluoroethylene (PVDF-TrFE) nano-fibers using an electrospinning technique. The dielectric response of the polymer was improved by incorporating the reduced-graphene-oxide (rGO) multi-walled carbon nano-tubes (MWCNTs) through doping. The dielectric behavior and piezoelectric effect were improved through the stretching and orientation of polymeric chains. The outermost layer was attained by chemical vapor deposition (CVD) of conductive polymer poly (3,4-ethylenedioxythiophene) to enhance the electrical conductivity and sensitivity. The hetero-structured nano-composite comprises PVDF-TrFE doped with rGO-MWCNTs over poly (3,4-ethylenedioxythiophene) (PEDOT), forming continuous self-assembly. The piezoelectric pressure sensor is capable of detecting human physiological vital signs. The pressure sensor exhibits a high-pressure sensitivity of 19.09 kPa−1, over a sensing range of 1.0 Pa to 25 kPa, and excellent cycling stability of 10,000 cycles. The study reveals that the piezoelectric pressure sensor has superior sensing performance and is capable of monitoring human vital signs, including heartbeat and wrist pulse, masticatory movement, voice recognition, and eye blinking signals. The research work demonstrates that the device could potentially eliminate metallic sensors and be used for early disease diagnosis in biomedical and personal healthcare applications. Full article
(This article belongs to the Special Issue Polymer Based Electronic Devices and Sensors III)
Show Figures

Figure 1

13 pages, 951 KiB  
Article
Human Activity Recognition Algorithm with Physiological and Inertial Signals Fusion: Photoplethysmography, Electrodermal Activity, and Accelerometry
by Justin Gilmore and Mona Nasseri
Sensors 2024, 24(10), 3005; https://doi.org/10.3390/s24103005 - 9 May 2024
Cited by 7 | Viewed by 2125
Abstract
Inertial signals are the most widely used signals in human activity recognition (HAR) applications, and extensive research has been performed on developing HAR classifiers using accelerometer and gyroscope data. This study aimed to investigate the potential enhancement of HAR models through the fusion [...] Read more.
Inertial signals are the most widely used signals in human activity recognition (HAR) applications, and extensive research has been performed on developing HAR classifiers using accelerometer and gyroscope data. This study aimed to investigate the potential enhancement of HAR models through the fusion of biological signals with inertial signals. The classification of eight common low-, medium-, and high-intensity activities was assessed using machine learning (ML) algorithms, trained on accelerometer (ACC), blood volume pulse (BVP), and electrodermal activity (EDA) data obtained from a wrist-worn sensor. Two types of ML algorithms were employed: a random forest (RF) trained on features; and a pre-trained deep learning (DL) network (ResNet-18) trained on spectrogram images. Evaluation was conducted on both individual activities and more generalized activity groups, based on similar intensity. Results indicated that RF classifiers outperformed corresponding DL classifiers at both individual and grouped levels. However, the fusion of EDA and BVP signals with ACC data improved DL classifier performance compared to a baseline DL model with ACC-only data. The best performance was achieved by a classifier trained on a combination of ACC, EDA, and BVP images, yielding F1-scores of 69 and 87 for individual and grouped activity classifications, respectively. For DL models trained with additional biological signals, almost all individual activity classifications showed improvement (p-value < 0.05). In grouped activity classifications, DL model performance was enhanced for low- and medium-intensity activities. Exploring the classification of two specific activities, ascending/descending stairs and cycling, revealed significantly improved results using a DL model trained on combined ACC, BVP, and EDA spectrogram images (p-value < 0.05). Full article
(This article belongs to the Section Wearables)
Show Figures

Figure 1

11 pages, 2694 KiB  
Article
Artery Pulse Waveform Acquired with a Fabry-Perot Interferometer
by Sergio Calixto, Zacarias Malacara-Hernandez, Guillermo Garnica and Ingrid Chavez-Serrano
Sensors 2024, 24(9), 2855; https://doi.org/10.3390/s24092855 - 30 Apr 2024
Cited by 1 | Viewed by 1520
Abstract
For most patients admitted to a hospital, it is a requirement to continuously monitor their vital signs. Among these are the waveforms from ECG and the pulmonary arterial pulse. At present, there are several electronic devices that can measure the arterial pulse waveform. [...] Read more.
For most patients admitted to a hospital, it is a requirement to continuously monitor their vital signs. Among these are the waveforms from ECG and the pulmonary arterial pulse. At present, there are several electronic devices that can measure the arterial pulse waveform. However, they can be affected by electromagnetic wave radiation, and the fabrication of electronic sensors is complicated and contributes to the e-waste, among other problems. In this paper, we propose an optical method to measure arterial pulse based on a Fabry-Perot interferometer composed of two mirrors. A pulse sensor formed by an acrylic cell with a thin membrane is used to gather the vasodilatation of the wrist, forming an air pulse that is enacted by means of a tube to a metallic cell containing a mirror that is glued to a thin silicone membrane. When the air pulse arrives, a displacement of the mirror takes place and produces a shift of the interference pattern fringes given by the Fabry-Perot. A detector samples the fringe intensity. With this method, an arterial pulse waveform is obtained. We characterize this optical device as a test of concept, and its application to measuring artery pulse is presented. The optical device is compared to other electronic devices. Full article
(This article belongs to the Special Issue Optical Instruments and Sensors and Their Applications)
Show Figures

Figure 1

18 pages, 3243 KiB  
Article
Changes in Maternal Heart Rate Variability and Photoplethysmography Morphology after Corticosteroid Administration: A Prospective, Observational Study
by Maretha Bester, Thomas J. Nichting, Rohan Joshi, Lamyae Aissati, Guid S. Oei, Massimo Mischi, Judith O. E. H. van Laar and Rik Vullings
J. Clin. Med. 2024, 13(8), 2442; https://doi.org/10.3390/jcm13082442 - 22 Apr 2024
Viewed by 1603
Abstract
Background: Owing to the association between dysfunctional maternal autonomic regulation and pregnancy complications, assessing non-invasive features reflecting autonomic activity—e.g., heart rate variability (HRV) and the morphology of the photoplethysmography (PPG) pulse wave—may aid in tracking maternal health. However, women with early pregnancy [...] Read more.
Background: Owing to the association between dysfunctional maternal autonomic regulation and pregnancy complications, assessing non-invasive features reflecting autonomic activity—e.g., heart rate variability (HRV) and the morphology of the photoplethysmography (PPG) pulse wave—may aid in tracking maternal health. However, women with early pregnancy complications typically receive medication, such as corticosteroids, and the effect of corticosteroids on maternal HRV and PPG pulse wave morphology is not well-researched. Methods: We performed a prospective, observational study assessing the effect of betamethasone (a commonly used corticosteroid) on non-invasively assessed features of autonomic regulation. Sixty-one women with an indication for betamethasone were enrolled and wore a wrist-worn PPG device for at least four days, from which five-minute measurements were selected for analysis. A baseline measurement was selected either before betamethasone administration or sufficiently thereafter (i.e., three days after the last injection). Furthermore, measurements were selected 24, 48, and 72 h after betamethasone administration. HRV features in the time domain and frequency domain and describing heart rate (HR) complexity were calculated, along with PPG morphology features. These features were compared between the different days. Results: Maternal HR was significantly higher and HRV features linked to parasympathetic activity were significantly lower 24 h after betamethasone administration. Features linked to sympathetic activity remained stable. Furthermore, based on the PPG morphology features, betamethasone appears to have a vasoconstrictive effect. Conclusions: Our results suggest that administering betamethasone affects maternal autonomic regulation and cardiovasculature. Researchers assessing maternal HRV in complicated pregnancies should schedule measurements before or sufficiently after corticosteroid administration. Full article
(This article belongs to the Special Issue Management of Pregnancy Complications)
Show Figures

Figure 1

13 pages, 2580 KiB  
Article
Simultaneous Measurement of Local Pulse Wave Velocities in Radial Arteries Using a Soft Sensor Based on the Fiber Bragg Grating Technique
by Jing Wang, Zhukun Wang, Zijun Zhang, Peiyun Li, Han Pan, Yong Ren, Tuo Hou, Chengbo Wang, Chiew-Foong Kwong, Bei Zhang, Sen Yang and Jing Bie
Micromachines 2024, 15(4), 507; https://doi.org/10.3390/mi15040507 - 8 Apr 2024
Cited by 5 | Viewed by 2115
Abstract
Arterial stiffness has been proved to be an important parameter in the evaluation of cardiovascular diseases, and Pulse Wave Velocity (PWV) is a strong indicator of arterial stiffness. Compared to regional PWV (PWV among different arteries), local PWV (PWV within a single artery) [...] Read more.
Arterial stiffness has been proved to be an important parameter in the evaluation of cardiovascular diseases, and Pulse Wave Velocity (PWV) is a strong indicator of arterial stiffness. Compared to regional PWV (PWV among different arteries), local PWV (PWV within a single artery) outstands in providing higher precision in indicating arterial properties, as regional PWVs are highly affected by multiple parameters, e.g., variations in blood vessel lengths due to individual differences, and multiple reflection effects on the pulse waveform. However, local PWV is less-developed due to its high dependency on the temporal resolution in synchronized signals with usually low signal-to-noise ratios. This paper presents a method for the noninvasive simultaneous measurement of two local PWVs in both left and right radial arteries based on the Fiber Bragg Grating (FBG) technique via correlation analysis of the pulse pairs at the fossa cubitalis and at the wrist. Based on the measurements of five male volunteers at the ages of 19 to 21 years old, the average left radial PWV ranged from 9.44 m/s to 12.35 m/s and the average right radial PWV ranged from 11.50 m/s to 14.83 m/s. What is worth mentioning is that a stable difference between the left and right radial PWVs was observed for each volunteer, ranging from 2.27 m/s to 3.04 m/s. This method enables the dynamic analysis of local PWVs and analysis of their features among different arteries, which will benefit the diagnosis of early-stage arterial stiffening and may bring more insights into the diagnosis of cardiovascular diseases. Full article
(This article belongs to the Special Issue Soft Actuators: Design, Fabrication and Applications)
Show Figures

Figure 1

12 pages, 6691 KiB  
Article
A Flexible Wearable Sensor Based on Laser-Induced Graphene for High-Precision Fine Motion Capture for Pilots
by Xiaoqing Xing, Yao Zou, Mian Zhong, Shichen Li, Hongyun Fan, Xia Lei, Juhang Yin, Jiaqing Shen, Xinyi Liu, Man Xu, Yong Jiang, Tao Tang, Yu Qian and Chao Zhou
Sensors 2024, 24(4), 1349; https://doi.org/10.3390/s24041349 - 19 Feb 2024
Cited by 6 | Viewed by 3167
Abstract
There has been a significant shift in research focus in recent years toward laser-induced graphene (LIG), which is a high-performance material with immense potential for use in energy storage, ultrahydrophobic water applications, and electronic devices. In particular, LIG has demonstrated considerable potential in [...] Read more.
There has been a significant shift in research focus in recent years toward laser-induced graphene (LIG), which is a high-performance material with immense potential for use in energy storage, ultrahydrophobic water applications, and electronic devices. In particular, LIG has demonstrated considerable potential in the field of high-precision human motion posture capture using flexible sensing materials. In this study, we investigated the surface morphology evolution and performance of LIG formed by varying the laser energy accumulation times. Further, to capture human motion posture, we evaluated the performance of highly accurate flexible wearable sensors based on LIG. The experimental results showed that the sensors prepared using LIG exhibited exceptional flexibility and mechanical performance when the laser energy accumulation was optimized three times. They exhibited remarkable attributes, such as high sensitivity (~41.4), a low detection limit (0.05%), a rapid time response (response time of ~150 ms; relaxation time of ~100 ms), and excellent response stability even after 2000 s at a strain of 1.0% or 8.0%. These findings unequivocally show that flexible wearable sensors based on LIG have significant potential for capturing human motion posture, wrist pulse rates, and eye blinking patterns. Moreover, the sensors can capture various physiological signals for pilots to provide real-time capturing. Full article
Show Figures

Figure 1

15 pages, 3277 KiB  
Article
Novel Conductive AgNP-Based Adhesive Based on Novel Poly (Ionic Liquid)-Based Waterborne Polyurethane Chloride Salts for E-Textiles
by Haiyang Liao, Yeqi Xiao, Tiemin Xiao, Hongjin Kuang, Xiaolong Feng, Xiao Sun, Guixin Cui, Xiaofei Duan and Pu Shi
Polymers 2024, 16(4), 540; https://doi.org/10.3390/polym16040540 - 17 Feb 2024
Cited by 1 | Viewed by 1743
Abstract
The emergence of novel e-textile materials that combine the inherent qualities of the textile substrate (lightweight, soft, breathable, durable, etc.) with the functionality of micro/nano-electronic materials (conductive, dielectric, sensing, etc.) has resulted in a trend toward miniaturization, integration, and intelligence in new electronic [...] Read more.
The emergence of novel e-textile materials that combine the inherent qualities of the textile substrate (lightweight, soft, breathable, durable, etc.) with the functionality of micro/nano-electronic materials (conductive, dielectric, sensing, etc.) has resulted in a trend toward miniaturization, integration, and intelligence in new electronic devices. However, the formation of a conductive network by micro/nano-conductive materials on textiles necessitates high-temperature sintering, which inevitably causes substrate aging and component damage. Herein, a bis-hydroxy-imidazolium chloride salt as a hard segment to synthesize a waterborne polyurethane (WPU) adhesive is designed and prepared. When used in nano-silver-based printing coatings, it offers strong adherence for coatings, reaching 16 N cm−1; on the other hand, the introduction of chloride ions enables low-temperature (60 °C) chemical sintering to address the challenge of secondary treatment and high-temperature sintering (>150 °C). Printed into flexible circuits, the resistivity can be controlled by the content of imidazolium salts anchored in the molecular chain of the WPU from a maximum resistivity of 3.1 × 107 down to 5.8 × 10−5 Ω m, and it can conduct a Bluetooth-type finger pulse detector with such low resistivity. As a flexible circuit, it also offers high stability against washing and adhesion, which the resistivity only reduces less than 20% after washing 10 times and adhesion. Owing to the adjustability of the resistivity, we fabricated an all-textile flexible pressure sensor that accurately differentiates different external pressures (min. 10 g, ~29 Pa), recognizes forms, and detects joint motions (finger bending and wrist flexion). Full article
(This article belongs to the Special Issue Advanced Conductive Polymers for Electrochemical Applications)
Show Figures

Graphical abstract

Back to TopTop