Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = unwanted visual phenomena

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 1979 KB  
Review
Dysphotopsias or Unwanted Visual Phenomena after Cataract Surgery
by Ambroz Pusnik, Goran Petrovski and Xhevat Lumi
Life 2023, 13(1), 53; https://doi.org/10.3390/life13010053 - 24 Dec 2022
Cited by 27 | Viewed by 6953
Abstract
Dysphotopsias are unwanted visual phenomena that occur after cataract surgery. They represent some of the most common reasons for patient dissatisfaction after uncomplicated surgery for cataract phacoemulsification with in-the-bag intraocular lens (IOL) implantation. Depending on the form of the optical phenomenon and the [...] Read more.
Dysphotopsias are unwanted visual phenomena that occur after cataract surgery. They represent some of the most common reasons for patient dissatisfaction after uncomplicated surgery for cataract phacoemulsification with in-the-bag intraocular lens (IOL) implantation. Depending on the form of the optical phenomenon and the effect it poses on vision, dysphotopsias are divided into positive and negative type. Positive dysphotopsias are usually described by patients as glare, light streaks, starbursts, light arcs, rings, haloes, or flashes of light. Negative dysphotopsias are manifested as an arc-shaped shadow or line usually located in the temporal part of the visual field, similar to a temporal scotoma. In addition to their different clinical manifestations, positive and negative dysphotopsia also have different risk factors. Even though up to 67% of patients may experience positive dysphotopsia immediately after surgery, only 2.2% of the cases have persistent symptoms up to a year postoperatively. Surgical intervention may be indicated in 0.07% of cases. The incidence of negative dysphotopsias is up to 26% of all patients; however, by one year postoperatively, the symptoms usually persist in 0.13 to 3% of patients. For both types of dysphotopsia, preoperative patients’ education, accurate preoperative diagnostics, and use of an appropriate IOL design and material is mandatory. Despite all these measures, dysphotopsias may occur, and when noninvasive measures fail to improve symptoms, a surgical approach may be considered. Full article
(This article belongs to the Section Physiology and Pathology)
Show Figures

Figure 1

18 pages, 4842 KB  
Article
Analysis and Optimization of Material Flow inside the System of Rotary Coolers and Intake Pipeline via Discrete Element Method Modelling
by Jakub Hlosta, David Žurovec, Jiří Rozbroj, Álvaro Ramírez-Gómez, Jan Nečas and Jiří Zegzulka
Energies 2018, 11(7), 1849; https://doi.org/10.3390/en11071849 - 14 Jul 2018
Cited by 6 | Viewed by 4607
Abstract
There is hardly any industry that does not use transport, storage, and processing of particulate solids in its production process. In the past, all device designs were based on empirical relationships or the designer’s experience. In the field of particulate solids, however, the [...] Read more.
There is hardly any industry that does not use transport, storage, and processing of particulate solids in its production process. In the past, all device designs were based on empirical relationships or the designer’s experience. In the field of particulate solids, however, the discrete element method (DEM) has been increasingly used in recent years. This study shows how this simulation tool can be used in practice. More specifically, in dealing with operating problems with a rotary cooler which ensures the transport and cooling of the hot fly ash generated by combustion in fluidized bed boilers. For the given operating conditions, an analysis of the current cooling design was carried out, consisting of a non-standard intake pipeline, which divides and supplies the material to two rotary coolers. The study revealed shortcomings in both the pipeline design and the cooler design. The material was unevenly dispensed between the two coolers, which combined with the limited transport capacity of the coolers, led to overflowing and congestion of the whole system. Therefore, after visualization of the material flow and export of the necessary data using DEM design measures to mitigate these unwanted phenomena were carried out. Full article
(This article belongs to the Section F: Electrical Engineering)
Show Figures

Graphical abstract

Back to TopTop