12 pages, 3166 KiB  
Article
Impedance Characterization and Modeling of Gold, Silver, and PEDOT:PSS Ultra-Thin Tattoo Electrodes for Wearable Bioelectronics
by Antonello Mascia, Riccardo Collu, Nasreddine Makni, Mattia Concas, Massimo Barbaro and Piero Cosseddu
Sensors 2025, 25(15), 4568; https://doi.org/10.3390/s25154568 - 23 Jul 2025
Viewed by 337
Abstract
This study presents a comprehensive evaluation and an equivalent circuit modeling of the skin–electrode impedance characteristics of three types of ultra-thin tattoo electrodes, all based on Parylene C nanofilms but with different active materials: Gold, Silver, and PEDOT:PSS. Their performance was compared to [...] Read more.
This study presents a comprehensive evaluation and an equivalent circuit modeling of the skin–electrode impedance characteristics of three types of ultra-thin tattoo electrodes, all based on Parylene C nanofilms but with different active materials: Gold, Silver, and PEDOT:PSS. Their performance was compared to standard disposable Ag/AgCl electrodes. Impedance measurements were carried out on six human subjects under controlled conditions, assessing the frequency response in the range of 20 Hz to 1 kHz. For each subject, the impedance was recorded six times over one hour to investigate the stability and the temporal performance. The collected data were subsequently analyzed to model the electrical properties and interface behavior of each electrode type. The findings demonstrate that the tattoo electrodes offer impedance levels comparable to those of Ag/AgCl electrodes (in the order of tens of kΩ at 20 Hz), while providing additional benefits such as enhanced conformability, improved skin adhesion, and reduced skin irritation during use. Furthermore, the modeling of the skin–electrode interface through a more detailed equivalent circuit than the single time constant model enables a more detailed interface analysis and description, with fitting algorithm R2 scores of about 0.999 and 0.979 for the impedance magnitude and impedance phase, respectively. The proposed equivalent circuit offers valuable insights for optimizing electrode design, supporting the potential of Parylene C-based tattoo electrodes as promising alternatives for next-generation wearable bioelectronic applications. Full article
(This article belongs to the Special Issue Bioimpedance Measurements and Microelectrodes)
Show Figures

Figure 1

35 pages, 6415 KiB  
Review
Recent Advances in Conductive Hydrogels for Electronic Skin and Healthcare Monitoring
by Yan Zhu, Baojin Chen, Yiming Liu, Tiantian Tan, Bowen Gao, Lijun Lu, Pengcheng Zhu and Yanchao Mao
Biosensors 2025, 15(7), 463; https://doi.org/10.3390/bios15070463 - 18 Jul 2025
Viewed by 370
Abstract
In recent decades, flexible electronics have witnessed remarkable advancements in multiple fields, encompassing wearable electronics, human–machine interfaces (HMI), clinical diagnosis, and treatment, etc. Nevertheless, conventional rigid electronic devices are fundamentally constrained by their inherent non-stretchability and poor conformability, limitations that substantially impede their [...] Read more.
In recent decades, flexible electronics have witnessed remarkable advancements in multiple fields, encompassing wearable electronics, human–machine interfaces (HMI), clinical diagnosis, and treatment, etc. Nevertheless, conventional rigid electronic devices are fundamentally constrained by their inherent non-stretchability and poor conformability, limitations that substantially impede their practical applications. In contrast, conductive hydrogels (CHs) for electronic skin (E-skin) and healthcare monitoring have attracted substantial interest owing to outstanding features, including adjustable mechanical properties, intrinsic flexibility, stretchability, transparency, and diverse functional and structural designs. Considerable efforts focus on developing CHs incorporating various conductive materials to enable multifunctional wearable sensors and flexible electrodes, such as metals, carbon, ionic liquids (ILs), MXene, etc. This review presents a comprehensive summary of the recent advancements in CHs, focusing on their classifications and practical applications. Firstly, CHs are categorized into five groups based on the nature of the conductive materials employed. These categories include polymer-based, carbon-based, metal-based, MXene-based, and ionic CHs. Secondly, the promising applications of CHs for electrophysiological signals and healthcare monitoring are discussed in detail, including electroencephalogram (EEG), electrocardiogram (ECG), electromyogram (EMG), respiratory monitoring, and motion monitoring. Finally, this review concludes with a comprehensive summary of current research progress and prospects regarding CHs in the fields of electronic skin and health monitoring applications. Full article
Show Figures

Figure 1

13 pages, 4507 KiB  
Article
A Mechanical–Electrochemical Dual-Model E-Skin for the Monitoring of Cardiovascular Healthcare
by Jianxiao Fang, Yunting Jia, Zelong Liao, Bairui Qi and Tao Huang
Biosensors 2025, 15(1), 5; https://doi.org/10.3390/bios15010005 - 26 Dec 2024
Viewed by 1108
Abstract
The early monitoring of cardiovascular biomarkers is essential for the prevention and management of some cardiovascular diseases. Here, we present a novel, compact, and highly integrated skin electrode as a mechanical–electrochemical dual-model E-skin, designed for the real-time monitoring of heart rate and sweat [...] Read more.
The early monitoring of cardiovascular biomarkers is essential for the prevention and management of some cardiovascular diseases. Here, we present a novel, compact, and highly integrated skin electrode as a mechanical–electrochemical dual-model E-skin, designed for the real-time monitoring of heart rate and sweat ion concentration, two critical parameters for assessing cardiovascular health. As a pressure sensor, this E-skin is suitable for accurate heart rate monitoring, as it exhibits high sensitivity (25.2 pF·kPa−1), a low detection limit of 6 Pa, and a rapid response time of ~20 ms, which is attributed to the iontronic sensing interface between the skin and the electrode. Additionally, the electrode functions as a potassium ion-selective electrode based on chemical doping, achieving an enhanced response of 11 mV·mM−1. A test based on the real-time monitoring of a subject riding an indoor bike demonstrated the device’s capability to monitor heart rate and sweat potassium ion levels reliably and accurately. This advancement in wearable technology offers significant potential for enhancing patient care based on the early detection and proactive management of cardiovascular conditions. Full article
Show Figures

Figure 1

13 pages, 2944 KiB  
Article
Development of a Wearable Electromyographic Sensor with Aerosol Jet Printing Technology
by Stefano Perilli, Massimo Di Pietro, Emanuele Mantini, Martina Regazzetti, Pawel Kiper, Francesco Galliani, Massimo Panella and Dante Mantini
Bioengineering 2024, 11(12), 1283; https://doi.org/10.3390/bioengineering11121283 - 17 Dec 2024
Cited by 5 | Viewed by 1370
Abstract
Electromyographic (EMG) sensors are essential tools for analyzing muscle activity, but traditional designs often face challenges such as motion artifacts, signal variability, and limited wearability. This study introduces a novel EMG sensor fabricated using Aerosol Jet Printing (AJP) technology that addresses these limitations [...] Read more.
Electromyographic (EMG) sensors are essential tools for analyzing muscle activity, but traditional designs often face challenges such as motion artifacts, signal variability, and limited wearability. This study introduces a novel EMG sensor fabricated using Aerosol Jet Printing (AJP) technology that addresses these limitations with a focus on precision, flexibility, and stability. The innovative sensor design minimizes air interposition at the skin–electrode interface, thereby reducing variability and improving signal quality. AJP enables the precise deposition of conductive materials onto flexible substrates, achieving a thinner and more conformable sensor that enhances user comfort and wearability. Performance testing compared the novel sensor to commercially available alternatives, highlighting its superior impedance stability across frequencies, even under mechanical stress. Physiological validation on a human participant confirmed the sensor’s ability to accurately capture muscle activity during rest and voluntary contractions, with clear differentiation between low and high activity states. The findings highlight the sensor’s potential for diverse applications, such as clinical diagnostics, rehabilitation, and sports performance monitoring. This work establishes AJP technology as a novel approach for designing wearable EMG sensors, providing a pathway for further advancements in miniaturization, strain-insensitive designs, and real-world deployment. Future research will explore optimization for broader applications and larger populations. Full article
Show Figures

Graphical abstract

21 pages, 5220 KiB  
Article
A Closed-Loop Ear-Worn Wearable EEG System with Real-Time Passive Electrode Skin Impedance Measurement for Early Autism Detection
by Muhammad Sheeraz, Abdul Rehman Aslam, Emmanuel Mic Drakakis, Hadi Heidari, Muhammad Awais Bin Altaf and Wala Saadeh
Sensors 2024, 24(23), 7489; https://doi.org/10.3390/s24237489 - 24 Nov 2024
Cited by 1 | Viewed by 1770
Abstract
Autism spectrum disorder (ASD) is a chronic neurological disorder with the severity directly linked to the diagnosis age. The severity can be reduced if diagnosis and intervention are early (age < 2 years). This work presents a novel ear-worn wearable EEG system designed [...] Read more.
Autism spectrum disorder (ASD) is a chronic neurological disorder with the severity directly linked to the diagnosis age. The severity can be reduced if diagnosis and intervention are early (age < 2 years). This work presents a novel ear-worn wearable EEG system designed to aid in the early detection of ASD. Conventional EEG systems often suffer from bulky, wired electrodes, high power consumption, and a lack of real-time electrode–skin interface (ESI) impedance monitoring. To address these limitations, our system incorporates continuous, long-term EEG recording, on-chip machine learning for real-time ASD prediction, and a passive ESI evaluation system. The passive ESI methodology evaluates impedance using the root mean square voltage of the output signal, considering factors like pressure, electrode surface area, material, gel thickness, and duration. The on-chip machine learning processor, implemented in 180 nm CMOS, occupies a minimal 2.52 mm² of active area while consuming only 0.87 µJ of energy per classification. The performance of this ML processor is validated using the Old Dominion University ASD dataset. Full article
(This article belongs to the Section Biomedical Sensors)
Show Figures

Figure 1

20 pages, 4559 KiB  
Article
Motion Artifacts in Dynamic EEG Recordings: Experimental Observations, Electrical Modelling, and Design Considerations
by Alessandra Giangrande, Alberto Botter, Harri Piitulainen and Giacinto Luigi Cerone
Sensors 2024, 24(19), 6363; https://doi.org/10.3390/s24196363 - 30 Sep 2024
Cited by 3 | Viewed by 3091
Abstract
Despite the progress in the development of innovative EEG acquisition systems, their use in dynamic applications is still limited by motion artifacts compromising the interpretation of the collected signals. Therefore, extensive research on the genesis of motion artifacts in EEG recordings is still [...] Read more.
Despite the progress in the development of innovative EEG acquisition systems, their use in dynamic applications is still limited by motion artifacts compromising the interpretation of the collected signals. Therefore, extensive research on the genesis of motion artifacts in EEG recordings is still needed to optimize existing technologies, shedding light on possible solutions to overcome the current limitations. We identified three potential sources of motion artifacts occurring at three different levels of a traditional biopotential acquisition chain: the skin-electrode interface, the connecting cables between the detection and the acquisition systems, and the electrode-amplifier system. The identified sources of motion artifacts were modelled starting from experimental observations carried out on EEG signals. Consequently, we designed customized EEG electrode systems aiming at experimentally disentangling the possible causes of motion artifacts. Both analytical and experimental observations indicated two main residual sites responsible for motion artifacts: the connecting cables between the electrodes and the amplifier and the sudden changes in electrode-skin impedance due to electrode movements. We concluded that further advancements in EEG technology should focus on the transduction stage of the biopotentials amplification chain, such as the electrode technology and its interfacing with the acquisition system. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

13 pages, 4393 KiB  
Article
A Cost-Effective and Easy-to-Fabricate Conductive Velcro Dry Electrode for Durable and High-Performance Biopotential Acquisition
by Jun Guo, Xuanqi Wang, Ruiyu Bai, Zimo Zhang, Huazhen Chen, Kai Xue, Chuang Ma, Dawei Zang, Erwei Yin, Kunpeng Gao and Bowen Ji
Biosensors 2024, 14(9), 432; https://doi.org/10.3390/bios14090432 - 6 Sep 2024
Cited by 2 | Viewed by 2114
Abstract
Compared with the traditional gel electrode, the dry electrode is being taken more seriously in bioelectrical recording because of its easy preparation, long-lasting ability, and reusability. However, the commonly used dry AgCl electrodes and silver cloth electrodes are generally hard to record through [...] Read more.
Compared with the traditional gel electrode, the dry electrode is being taken more seriously in bioelectrical recording because of its easy preparation, long-lasting ability, and reusability. However, the commonly used dry AgCl electrodes and silver cloth electrodes are generally hard to record through hair due to their flat contact surface. Claw electrodes can contact skin through hair on the head and body, but the internal claw structure is relatively hard and causes discomfort after being worn for a few hours. Here, we report a conductive Velcro electrode (CVE) with an elastic hook hair structure, which can collect biopotential through body hair. The elastic hooks greatly reduce discomfort after long-time wearing and can even be worn all day. The CVE electrode is fabricated by one-step immersion in conductive silver paste based on the cost-effective commercial Velcro, forming a uniform and durable conductive coating on a cluster of hook microstructures. The electrode shows excellent properties, including low impedance (15.88 kΩ @ 10 Hz), high signal-to-noise ratio (16.0 dB), strong water resistance, and mechanical resistance. After washing in laundry detergent, the impedance of CVE is still 16% lower than the commercial AgCl electrodes. To verify the mechanical strength and recovery capability, we conducted cyclic compression experiments. The results show that the displacement change of the electrode hook hair after 50 compression cycles was still less than 1%. This electrode provides a universal acquisition scheme, including effective acquisition of different parts of the body with or without hair. Finally, the gesture recognition from electromyography (EMG) by the CVE electrode was applied with accuracy above 90%. The CVE proposed in this study has great potential and promise in various human–machine interface (HMI) applications that employ surface biopotential signals on the body or head with hair. Full article
Show Figures

Figure 1

13 pages, 4035 KiB  
Article
Minimization of Parasitic Capacitance between Skin and Ag/AgCl Dry Electrodes
by Sungcheol Hong and Gerard Coté
Micromachines 2024, 15(7), 907; https://doi.org/10.3390/mi15070907 - 12 Jul 2024
Cited by 3 | Viewed by 1680
Abstract
Conventional dry electrodes often yield unstable results due to the presence of parasitic capacitance between the flat electrode surface and the non-uniform skin interface. To address this issue, a gel is typically placed between the electrodes to minimize parasitic capacitance. However, this approach [...] Read more.
Conventional dry electrodes often yield unstable results due to the presence of parasitic capacitance between the flat electrode surface and the non-uniform skin interface. To address this issue, a gel is typically placed between the electrodes to minimize parasitic capacitance. However, this approach has the drawbacks of being unsuitable for repeated use, limited lifetime due to gel evaporation, and the possibility of developing skin irritation. This is particularly problematic in underserved areas since, due to the cost of disposable wet electrodes, they often sterilize and reuse dry electrodes. In this study, we propose a method to neutralize the effects of parasitic capacitance by attaching high-value capacitors to the electrodes in parallel, specifically when applied to pulse wave monitoring through bioimpedance. Skin capacitance can also be mitigated due to the serial connection, enabling stable reception of arterial pulse signals through bioimpedance circuits. A high-frequency structure simulator (HFSS) was first used to simulate the capacitance when injection currents flow into the arteries through the bioimpedance circuits. We also used the simulation to investigate the effects of add-on capacitors. Lastly, we conducted preliminary comparative analyses between wet electrodes and dry electrodes in vivo with added capacitance values ranging from 100 pF to 1 μF, altering capacitance magnitudes by factors of 100. As a result, we obtained a signal-to-noise ratio (SNR) that was 8.2 dB higher than that of dry electrodes. Performance was also shown to be comparable to wet electrodes, with a reduction of only 0.4 dB using 1 μF. The comparative results demonstrate that the addition of capacitors to the electrodes has the potential to allow for performance similar to that of wet electrodes for bioimpedance pulse rate monitoring and could potentially be used for other applications of dry electrodes. Full article
(This article belongs to the Section B:Biology and Biomedicine)
Show Figures

Figure 1

15 pages, 3447 KiB  
Article
MXene-Based Flexible Electrodes for Electrophysiological Monitoring
by Meera Alex, Kashif Rast Baz Khan, Amani Al-Othman, Mohammad H. Al-Sayah and Hasan Al Nashash
Sensors 2024, 24(11), 3260; https://doi.org/10.3390/s24113260 - 21 May 2024
Cited by 5 | Viewed by 2620
Abstract
The advancement of flexible electrodes triggered research on wearables and health monitoring applications. Metal-based bioelectrodes encounter low mechanical strength and skin discomfort at the electrode–skin interface. Thus, recent research has focused on the development of flexible surface electrodes with low electrochemical resistance and [...] Read more.
The advancement of flexible electrodes triggered research on wearables and health monitoring applications. Metal-based bioelectrodes encounter low mechanical strength and skin discomfort at the electrode–skin interface. Thus, recent research has focused on the development of flexible surface electrodes with low electrochemical resistance and high conductivity. This study investigated the development of a novel, flexible, surface electrode based on a MXene/polydimethylsiloxane (PDMS)/glycerol composite. MXenes offer the benefit of featuring highly conductive transition metals with metallic properties, including a group of carbides, nitrides, and carbonitrides, while PDMS exhibits inherent biostability, flexibility, and biocompatibility. Among the various MXene-based electrode compositions prepared in this work, those composed of 15% and 20% MXene content were further evaluated for their potential in electrophysiological sensing applications. The samples underwent a range of characterization techniques, including electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), as well as mechanical and bio-signal sensing from the skin. The experimental findings indicated that the compositions demonstrated favorable bulk impedances of 280 and 111 Ω, along with conductivities of 0.462 and 1.533 mS/cm, respectively. Additionally, they displayed promising electrochemical stability, featuring charge storage densities of 0.665 mC/cm2 and 1.99 mC/cm2, respectively. By conducting mechanical tests, Young’s moduli were determined to be 2.61 MPa and 2.18 MPa, respectively. The composite samples exhibited elongation of 139% and 144%, respectively. Thus, MXene-based bioelectrodes show promising potential for flexible and wearable electronics and bio-signal sensing applications. Full article
Show Figures

Figure 1

18 pages, 7401 KiB  
Article
Hydrogels and Carbon Nanotubes: Composite Electrode Materials for Long-Term Electrocardiography Monitoring
by Leszek Kolodziej, Olga Iwasińska-Kowalska, Grzegorz Wróblewski, Tomasz Giżewski, Małgorzata Jakubowska and Agnieszka Lekawa-Raus
J. Funct. Biomater. 2024, 15(5), 113; https://doi.org/10.3390/jfb15050113 - 23 Apr 2024
Cited by 4 | Viewed by 2263
Abstract
This paper presents methods for developing high-performance interface electrode materials designed to enhance signal collection efficacy during long-term (over 24 h) electrocardiography (ECG) monitoring. The electrode materials are fabricated by integrating commercial ECG liquid hydrogels with carbon nanotubes (CNTs), which are widely utilized [...] Read more.
This paper presents methods for developing high-performance interface electrode materials designed to enhance signal collection efficacy during long-term (over 24 h) electrocardiography (ECG) monitoring. The electrode materials are fabricated by integrating commercial ECG liquid hydrogels with carbon nanotubes (CNTs), which are widely utilized in dry-electrode technologies and extensively discussed in the current scientific literature. The composite materials are either prepared by dispersing CNTs within the commercial liquid hydrogel matrix or by encasing the hydrogels in macroscopic CNT films. Both approaches ensure the optimal wetting of the epidermis via the hydrogels, while the CNTs reduce material impedance and stabilize the drying process. The resulting electrode materials maintain their softness, allowing for micro-conformal skin attachment, and are biocompatible. Empirical testing confirms that the ECG electrodes employing these hybrid hydrogels adhere to relevant standards for durations exceeding 24 h. These innovative hybrid solutions merge the benefits of both wet and dry ECG electrode technologies, potentially facilitating the extended monitoring of ECG signals and thus advancing the diagnosis and treatment of various cardiac conditions. Full article
(This article belongs to the Section Biomaterials and Devices for Healthcare Applications)
Show Figures

Figure 1

11 pages, 8847 KiB  
Article
Solvent-Free and Cost-Efficient Fabrication of a High-Performance Nanocomposite Sensor for Recording of Electrophysiological Signals
by Shuyun Zhuo, Anan Zhang, Alexandre Tessier, Chris Williams and Shideh Kabiri Ameri
Biosensors 2024, 14(4), 188; https://doi.org/10.3390/bios14040188 - 11 Apr 2024
Cited by 5 | Viewed by 4562
Abstract
Carbon nanotube (CNT)-based nanocomposites have found applications in making sensors for various types of physiological sensing. However, the sensors’ fabrication process is usually complex, multistep, and requires longtime mixing and hazardous solvents that can be harmful to the environment. Here, we report a [...] Read more.
Carbon nanotube (CNT)-based nanocomposites have found applications in making sensors for various types of physiological sensing. However, the sensors’ fabrication process is usually complex, multistep, and requires longtime mixing and hazardous solvents that can be harmful to the environment. Here, we report a flexible dry silver (Ag)/CNT/polydimethylsiloxane (PDMS) nanocomposite-based sensor made by a solvent-free, low-temperature, time-effective, and simple approach for electrophysiological recording. By mechanical compression and thermal treatment of Ag/CNT, a connected conductive network of the fillers was formed, after which the PDMS was added as a polymer matrix. The CNTs make a continuous network for electrons transport, endowing the nanocomposite with high electrical conductivity, mechanical strength, and durability. This process is solvent-free and does not require a high temperature or complex mixing procedure. The sensor shows high flexibility and good conductivity. High-quality electroencephalography (EEG) and electrooculography (EOG) were performed using fabricated dry sensors. Our results show that the Ag/CNT/PDMS sensor has comparable skin–sensor interface impedance with commercial Ag/AgCl-coated dry electrodes, better performance for noninvasive electrophysiological signal recording, and a higher signal-to-noise ratio (SNR) even after 8 months of storage. The SNR of electrophysiological signal recording was measured to be 26.83 dB for our developed sensors versus 25.23 dB for commercial Ag/AgCl-coated dry electrodes. Our process of compress-heating the functional fillers provides a universal approach to fabricate various types of nanocomposites with different nanofillers and desired electrical and mechanical properties. Full article
(This article belongs to the Special Issue Nanoparticle-Based Biosensors for Detection)
Show Figures

Figure 1

13 pages, 9646 KiB  
Article
Design, Fabrication and Evaluation of a Stretchable High-Density Electromyography Array
by Rejin John Varghese, Matteo Pizzi, Aritra Kundu, Agnese Grison, Etienne Burdet and Dario Farina
Sensors 2024, 24(6), 1810; https://doi.org/10.3390/s24061810 - 11 Mar 2024
Cited by 10 | Viewed by 5437
Abstract
The adoption of high-density electrode systems for human–machine interfaces in real-life applications has been impeded by practical and technical challenges, including noise interference, motion artefacts and the lack of compact electrode interfaces. To overcome some of these challenges, we introduce a wearable and [...] Read more.
The adoption of high-density electrode systems for human–machine interfaces in real-life applications has been impeded by practical and technical challenges, including noise interference, motion artefacts and the lack of compact electrode interfaces. To overcome some of these challenges, we introduce a wearable and stretchable electromyography (EMG) array, and present its design, fabrication methodology, characterisation, and comprehensive evaluation. Our proposed solution comprises dry-electrodes on flexible printed circuit board (PCB) substrates, eliminating the need for time-consuming skin preparation. The proposed fabrication method allows the manufacturing of stretchable sleeves, with consistent and standardised coverage across subjects. We thoroughly tested our developed prototype, evaluating its potential for application in both research and real-world environments. The results of our study showed that the developed stretchable array matches or outperforms traditional EMG grids and holds promise in furthering the real-world translation of high-density EMG for human–machine interfaces. Full article
(This article belongs to the Special Issue EMG Sensors and Signal Processing Technologies)
Show Figures

Figure 1

16 pages, 8433 KiB  
Article
An Approach to Using Electrical Impedance Myography Signal Sensors to Assess Morphofunctional Changes in Tissue during Muscle Contraction
by Vladislava Kapravchuk, Andrey Briko, Alexander Kobelev, Ahmad Hammoud and Sergey Shchukin
Biosensors 2024, 14(2), 76; https://doi.org/10.3390/bios14020076 - 31 Jan 2024
Cited by 9 | Viewed by 2488
Abstract
This present work is aimed at conducting fundamental and exploratory studies of the mechanisms of electrical impedance signal formation. This paper also considers morphofunctional changes in forearm tissues during the performance of basic hand actions. For this purpose, the existing research benches were [...] Read more.
This present work is aimed at conducting fundamental and exploratory studies of the mechanisms of electrical impedance signal formation. This paper also considers morphofunctional changes in forearm tissues during the performance of basic hand actions. For this purpose, the existing research benches were modernized to conduct experiments of mapping forearm muscle activity by electrode systems on the basis of complexing the electrical impedance signals and electromyography signals and recording electrode systems’ pressing force using force transducers. Studies were carried out with the involvement of healthy volunteers in the implementation of vertical movement of the electrode system and ultrasound transducer when the subject’s upper limb was positioned in the bed of the stand while performing basic hand actions in order to identify the relationship between the morphofunctional activity of the upper limb muscles and the recorded parameters of the electro-impedance myography signal. On the basis of the results of the studies, including complex measurements of neuromuscular activity on healthy volunteers such as the signals of electro-impedance myography and pressing force, analyses of the morphofunctional changes in tissues during action performance on the basis of ultrasound and MRI studies and the factors influencing the recorded signals of electro-impedance myography are described. The results are of fundamental importance and will enable reproducible electro-impedance myography signals, which, in turn, allow improved anthropomorphic control. Full article
(This article belongs to the Special Issue Biospectroscopy-Based Biosensing Platforms)
Show Figures

Figure 1

19 pages, 1902 KiB  
Article
A Fusion Algorithm Based on a Constant Velocity Model for Improving the Measurement of Saccade Parameters with Electrooculography
by Palpolage Don Shehan Hiroshan Gunawardane, Raymond Robert MacNeil, Leo Zhao, James Theodore Enns, Clarence Wilfred de Silva and Mu Chiao
Sensors 2024, 24(2), 540; https://doi.org/10.3390/s24020540 - 15 Jan 2024
Cited by 1 | Viewed by 2079
Abstract
Electrooculography (EOG) serves as a widely employed technique for tracking saccadic eye movements in a diverse array of applications. These encompass the identification of various medical conditions and the development of interfaces facilitating human–computer interaction. Nonetheless, EOG signals are often met with skepticism [...] Read more.
Electrooculography (EOG) serves as a widely employed technique for tracking saccadic eye movements in a diverse array of applications. These encompass the identification of various medical conditions and the development of interfaces facilitating human–computer interaction. Nonetheless, EOG signals are often met with skepticism due to the presence of multiple sources of noise interference. These sources include electroencephalography, electromyography linked to facial and extraocular muscle activity, electrical noise, signal artifacts, skin-electrode drifts, impedance fluctuations over time, and a host of associated challenges. Traditional methods of addressing these issues, such as bandpass filtering, have been frequently utilized to overcome these challenges but have the associated drawback of altering the inherent characteristics of EOG signals, encompassing their shape, magnitude, peak velocity, and duration, all of which are pivotal parameters in research studies. In prior work, several model-based adaptive denoising strategies have been introduced, incorporating mechanical and electrical model-based state estimators. However, these approaches are really complex and rely on brain and neural control models that have difficulty processing EOG signals in real time. In this present investigation, we introduce a real-time denoising method grounded in a constant velocity model, adopting a physics-based model-oriented approach. This approach is underpinned by the assumption that there exists a consistent rate of change in the cornea-retinal potential during saccadic movements. Empirical findings reveal that this approach remarkably preserves EOG saccade signals, resulting in a substantial enhancement of up to 29% in signal preservation during the denoising process when compared to alternative techniques, such as bandpass filters, constant acceleration models, and model-based fusion methods. Full article
Show Figures

Figure 1

10 pages, 5723 KiB  
Communication
Asymmetric Schottky Barrier in Rubrene Transistor via Monolayer Graphene Insertion toward Self-Powered Imaging
by Qing Liu, Xialian Zheng, Mengru Li, Qianqian Du, Chunhui Zhu, Wenjun Wang and Shuchao Qin
Materials 2023, 16(23), 7364; https://doi.org/10.3390/ma16237364 - 27 Nov 2023
Cited by 1 | Viewed by 1406
Abstract
Organic semiconductor materials featuring lightweight, and flexibility may play a significant role in various future applications, such as foldable displays, wearable devices, and artificial skin. For developing high-performance organic devices, organic crystals are highly desired, while a remaining fundamental issue is their contact [...] Read more.
Organic semiconductor materials featuring lightweight, and flexibility may play a significant role in various future applications, such as foldable displays, wearable devices, and artificial skin. For developing high-performance organic devices, organic crystals are highly desired, while a remaining fundamental issue is their contact problem. Here, we have grown a high-quality rubrene single crystal by utilizing a simple in-air sublimation technique. The contact characteristics (barrier height and contact resistance) are detail-studied by resist-free transfer electrodes (Au metal or graphene/Au). The Schottky barrier of the rubrene/graphene interface is lower and can be also modulated by gate bias, which is confirmed by spatial photocurrent mapping. Finally, we demonstrated the zero-bias photocurrent imaging application by constructing the asymmetrical device employing different electrode contacts. Our work would be of significance for studying the contact issue of organic crystals and wireless imaging. Full article
(This article belongs to the Special Issue Two-Dimensional Materials and Nano Devices)