Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (37)

Search Parameters:
Keywords = radiology dosimetry

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 1114 KiB  
Article
Establishing Diagnostic Reference Levels for Paediatric CT Imaging: A Multi-Centre Study
by Yassine Bouchareb, Manar Al Kharusi, Amani Al Maqbali, Amal Al Maimani, Hasina Al Maskari, Srinivasa Rao Sirasanagandla, Amna Al Jabri, Faiza Al Kindi, Saud Al Shabibi and Saleh Baawain
Healthcare 2025, 13(14), 1728; https://doi.org/10.3390/healthcare13141728 - 17 Jul 2025
Viewed by 324
Abstract
Background: Computed Tomography (CT) imaging is widely recognised for its high capability in assessing multiple organs. However, concerns about patient radiation exposure, particularly in children, pose significant challenges. Objective: This study aimed to establish diagnostic reference levels (DRLs) for paediatric patients in the [...] Read more.
Background: Computed Tomography (CT) imaging is widely recognised for its high capability in assessing multiple organs. However, concerns about patient radiation exposure, particularly in children, pose significant challenges. Objective: This study aimed to establish diagnostic reference levels (DRLs) for paediatric patients in the most common CT examinations to monitor and better control radiation doses. Methods: Dosimetry records from 5956 patients’ scans for the four most common CT imaging examinations—Head, Chest, Abdomen Pelvis (AP), and Chest Abdomen Pelvis (CAP)—were considered. The CT dosimetric quantities (CT dose-index volume (CTDIvol) and dose-length product (DLP)), along with patient demographics (age and weight), were collected from radiology data storage systems. DRLs for CTDIvol and DLP were determined for each imaging examination, stratified by patient age and weight groups, in accordance with ICRP recommendations. Results: The derived DRLs are presented as [median CTDIvol (mGy): median DLP (mGy·cm)]. For (<1 yr): Head: 13:187, Chest: 0.4:7, AP: 0.9:19, CAP: 0.4:10. For (1–5 yrs): Head: 16:276, Chest: 1:22, AP: 1.5:58, CAP: 1.6:63. For (6–10 yrs): Head: 19:332, Chest: 1.4:35, AP: 1.9:74, CAP: 2:121. For (11–15 yrs): Head: 21:391, Chest: 3:86, AP: 4.1:191, CAP: 3:165. We observed that both the CTDIvol and DLP DRL values increase with patient age. Weight-based DRLs follow similar trends for CTDIvol, while DLP values show noticeable variations in Chest and AP examinations. Conclusions: The study findings highlight the need for review and optimisation of certain scanning protocols, particularly for chest and AP examinations. The derived DRLs are consistent with findings from other studies. The study recommends establishing national paediatric DRLs to enhance radiology practice across the country and ensure adherence to international safety standards. Full article
(This article belongs to the Collection Radiology-Driven Projects: Science, Networks, and Healthcare)
Show Figures

Figure 1

17 pages, 3260 KiB  
Article
The Implementation and Application of a Saudi Voxel-Based Anthropomorphic Phantom in OpenMC for Radiological Imaging and Dosimetry
by Ali A. A. Alghamdi
Diagnostics 2025, 15(14), 1764; https://doi.org/10.3390/diagnostics15141764 - 12 Jul 2025
Viewed by 432
Abstract
Objectives: This study aimed to implement a high-resolution Saudi voxel-based anthropomorphic phantom in the OpenMC Monte Carlo (MC) simulation framework. The objective was to evaluate its applicability in radiological simulations, including radiographic imaging and effective dose calculations, tailored to the Saudi population. [...] Read more.
Objectives: This study aimed to implement a high-resolution Saudi voxel-based anthropomorphic phantom in the OpenMC Monte Carlo (MC) simulation framework. The objective was to evaluate its applicability in radiological simulations, including radiographic imaging and effective dose calculations, tailored to the Saudi population. Methods: A voxel phantom comprising 30 segmented organs/tissues and over 32 million voxels were constructed from full-body computed tomography data and integrated into OpenMC. The implementation involved detailed voxel mapping, material definition using ICRP/ICRU-116 recommendations, and lattice geometry construction. The simulations included X-ray radiography projections using mesh tallies and anterior–posterior effective dose calculations across 20 photon energies (10 keV–1 MeV). The absorbed dose was calculated using OpenMC’s heating tally and converted to an effective dose using tissue weighting factors. Results: The phantom was successfully modeled and visualized in OpenMC, demonstrating accurate anatomical representation. Radiographic projections showed optimal contrast at 70 keV. The effective dose values for 29 organs were calculated and compared with MCNPX, the ICRP-116 reference phantom, and XGBoost-based machine learning (ML) predictions. OpenMC results showed good agreement, with maximum deviations of −35.5% against ICRP-116 at 10 keV. Root mean square error (RMSE) comparisons confirmed reasonable alignment, with OpenMC displaying higher RMSEs relative to other methods due to expanded organ modeling and material definitions. Conclusions: The integration of the Saudi voxel phantom into OpenMC demonstrates its utility for high-resolution dosimetry and radiographic simulations. OpenMC’s Python (version 3.10.14) interface and open-source nature make it a promising tool for radiological research. Future work will focus on combining MC and ML approaches for enhanced predictive dosimetry. Full article
(This article belongs to the Section Medical Imaging and Theranostics)
Show Figures

Figure 1

15 pages, 1769 KiB  
Article
Exposure Time Dependence of Operators’ Head Entrance Air Kerma in Interventional Radiology Measured by TLD-100H Chips
by Rocco Mottareale, Francesco Manna, Patrizio Antonio Carmosino, Francesco Fiore, Marco Correra, Salvatore Stilo, Luca Tarotto and Mariagabriella Pugliese
Sensors 2025, 25(12), 3666; https://doi.org/10.3390/s25123666 - 11 Jun 2025
Viewed by 540
Abstract
Interventional radiology offers minimally invasive procedures guided by real-time imaging, reducing surgical risks and enhancing patient recovery. While beneficial to patients, these advancements increase occupational hazards for physicians due to chronic exposure to ionizing radiation. This exposure raises health risks like radiation-induced cataracts, [...] Read more.
Interventional radiology offers minimally invasive procedures guided by real-time imaging, reducing surgical risks and enhancing patient recovery. While beneficial to patients, these advancements increase occupational hazards for physicians due to chronic exposure to ionizing radiation. This exposure raises health risks like radiation-induced cataracts, cardiovascular disease, and cancer. Despite regulations like the European Council Directive 2013/59/EURATOM, which sets limits on whole-body and eye lens doses, no dose limits exist for the brain and meninges, since the brain has traditionally been considered a radioresistant organ. Recent studies, however, have highlighted radiation-induced brain damage, suggesting that meningeal exposure in interventional radiology may be underestimated. This study evaluates the entrance air Cumulative mean annual entrance air kerma to the skullull during interventional radiology procedures, using thermoluminescent dosimeters and controlled exposure simulations. Data were collected by varying the exposure time and analyzing the contribution to the entrance air kerma on each side of the head. The results indicate that, considering the attenuation of the cranial bone, the absorbed dose to the brain, obtained by averaging the head entrance air kerma for the right, front, and left sides of the operator’s head, could represent 0.81% to 2.18% of the annual regulatory limit in Italy of 20 mSv for the average annual effective dose of exposed workers (LD 101/2020). These results provide an assessment of brain exposure, highlighting the relatively low but non-negligible contribution of brain irradiation to the overall occupational dose constraint. Additionally, a correlation between entrance air kerma and the Kerma-Area Product was observed, providing a potential method for improved dose estimation and enhanced radiation safety for interventional radiologists. Full article
Show Figures

Figure 1

18 pages, 4199 KiB  
Article
Dosimetric Evaluation of the Sensitivity of PAGAT Gel Dosimeters Infused with Clinically Used Gadolinium-Based Contrast Agents
by Melani Fuentealba, Carolina Vallejos, Sergio Díez and Mauricio Santibáñez
Gels 2025, 11(6), 416; https://doi.org/10.3390/gels11060416 - 30 May 2025
Viewed by 259
Abstract
This study evaluates the impact of gadolinium-based contrast agents (Omniscan, Dotarem, and Gadovist) on the performance of PAGAT gel dosimeters using spectrophotometric analysis. Dosimeters were infused with gadolinium at concentrations ranging from 0 to 40 mg/mL and irradiated with a 6 MV photon [...] Read more.
This study evaluates the impact of gadolinium-based contrast agents (Omniscan, Dotarem, and Gadovist) on the performance of PAGAT gel dosimeters using spectrophotometric analysis. Dosimeters were infused with gadolinium at concentrations ranging from 0 to 40 mg/mL and irradiated with a 6 MV photon beam over a dose range of 0–15 Gy. Regarding dosimeter behavior, Dotarem exhibited an enhancement in optical density prior to irradiation due to polymerization reactions between the dosimeter and the contrast agent starting at 10 mg/mL, which compromised optical readings above 20 mg/mL. Omniscan consistently showed 37.7% lower sensitivity than standard PAGAT across all concentrations and dose levels. Conversely, Gadovist enhanced sensitivity by up to 50% at 20 mg/mL, with additional gains at higher concentrations, although accompanied by saturation at lower dose levels. Radiological analysis showed that all tested concentrations maintained mass energy–absorption coefficient differences below 1% and water-equivalence in effective atomic number within 5% at 6 MV. These findings underscore the importance of selecting an appropriate contrast agent to enhance gel dosimeter sensitivity, particularly in low-dose regions where measurement uncertainty increases. Additionally, gadolinium-infused PAGAT gels show strong potential for assessing dose enhancement phenomena. Their sensitivity, threshold behavior, and radiological properties suggest they may be suitable for applications in dose enhancement dosimetry as well as conventional clinical settings. Full article
(This article belongs to the Special Issue Advanced Hydrogels for Biomedical Applications)
Show Figures

Figure 1

25 pages, 4134 KiB  
Article
Evaluation of Environmental Radiation Exposure and Algorithms for Determining the Occupational Effective Dose During 99mTc-MDP Bone Scintigraphy: A Comprehensive Analysis
by Suphalak Khamruang Marshall, Awatif Hayeeabdunromae, Nadia Noomad, Wanita Durawee, Nantakorn Sirieak, Pornchanok Karnkorn and Virunyupa Keawtong
Appl. Sci. 2024, 14(23), 11211; https://doi.org/10.3390/app142311211 - 2 Dec 2024
Cited by 4 | Viewed by 23072
Abstract
This study evaluated the occupational exposure of radiopharmacists, nurses, radiological technologists, and radiological technologist assistants involved in 99mTc-MDP bone scintigraphy procedures. Actual occupational effective doses for individual staff needed ascertaining. An environmental radiation exposure audit revealed all nuclear medicine areas were compliant [...] Read more.
This study evaluated the occupational exposure of radiopharmacists, nurses, radiological technologists, and radiological technologist assistants involved in 99mTc-MDP bone scintigraphy procedures. Actual occupational effective doses for individual staff needed ascertaining. An environmental radiation exposure audit revealed all nuclear medicine areas were compliant with ICRP and IAEA guidelines. To ascertain individual doses, they were recorded by OSL badges. The highest exposure was to the radiopharmacists, Hp(0.07) 2.19 µSv during radiolabeling. The nurse administering 99mTc-MDP recorded a dose of 0.27 µSv at Hp(0.07), 26.01% of the total occupational effective dose. The radiological technologist and assistant receive 73.05% of the total effective dose. However, the highest effective dose was received by the technologist assistant positioning patients for SPECT/CT scans, with an effective dose of 32.03 µSv. Single and double dosimetry effective dose estimate algorithms were evaluated, resulting in the double dosimetry being more accurate. The Padovani et al. algorithm was found to most closely align with 99mTc-MDP actual effective dose values (p > 0.05), thereby validating the measurement methods used in this study. The research offers benchmark environmental exposure and effective doses applicable in audits and the continuous effort to enhance radiation safety for personnel during 99mTc-MDP bone scintigraphy. Full article
(This article belongs to the Special Issue Measurement and Assessment of Environmental Radioactivity)
Show Figures

Figure 1

21 pages, 7424 KiB  
Article
Neural Network Ensemble to Detect Dicentric Chromosomes in Metaphase Images
by Ignacio Atencia-Jiménez, Adayabalam S. Balajee, Miguel J. Ruiz-Gómez, Francisco Sendra-Portero, Alegría Montoro and Miguel A. Molina-Cabello
Appl. Sci. 2024, 14(22), 10440; https://doi.org/10.3390/app142210440 - 13 Nov 2024
Cited by 2 | Viewed by 1706
Abstract
The Dicentric Chromosome Assay (DCA) is widely used in biological dosimetry, where the number of dicentric chromosomes induced by ionizing radiation (IR) exposure is quantified to estimate the absorbed radiation dose an individual has received. Dicentric chromosome scoring is a laborious and time-consuming [...] Read more.
The Dicentric Chromosome Assay (DCA) is widely used in biological dosimetry, where the number of dicentric chromosomes induced by ionizing radiation (IR) exposure is quantified to estimate the absorbed radiation dose an individual has received. Dicentric chromosome scoring is a laborious and time-consuming process which is performed manually in most cytogenetic biodosimetry laboratories. Further, dicentric chromosome scoring constitutes a bottleneck when several hundreds of samples need to be analyzed for dose estimation in the aftermath of large-scale radiological/nuclear incident(s). Recently, much interest has focused on automating dicentric chromosome scoring using Artificial Intelligence (AI) tools to reduce analysis time and improve the accuracy of dicentric chromosome detection. Our study aims to detect dicentric chromosomes in metaphase plate images using an ensemble of artificial neural network detectors suitable for datasets that present a low number of samples (in this work, only 50 images). In our approach, the input image is first processed by several operators, each producing a transformed image. Then, each transformed image is transferred to a specific detector trained with a training set processed by the same operator that transformed the image. Following this, the detectors provide their predictions about the detected chromosomes. Finally, all predictions are combined using a consensus function. Regarding the operators used, images were binarized separately applying Otsu and Spline techniques, while morphological opening and closing filters with different sizes were used to eliminate noise, isolate specific components, and enhance the structures of interest (chromosomes) within the image. Consensus-based decisions are typically more precise than those made by individual networks, as the consensus method can rectify certain misclassifications, assuming that individual network results are correct. The results indicate that our methodology worked satisfactorily in detecting a majority of chromosomes, with remarkable classification performance even with the low number of training samples utilized. AI-based dicentric chromosome detection will be beneficial for a rapid triage by improving the detection of dicentric chromosomes and thereby the dose prediction accuracy. Full article
(This article belongs to the Special Issue New Insights into Computer Vision and Graphics)
Show Figures

Figure 1

10 pages, 3275 KiB  
Article
Radiation Exposure to the Brains of Interventional Radiology Staff: A Phantom Study
by Saya Ohno, Ryota Shindo, Satoe Konta, Keisuke Yamamoto, Yohei Inaba and Koichi Chida
Bioengineering 2024, 11(11), 1083; https://doi.org/10.3390/bioengineering11111083 - 29 Oct 2024
Cited by 4 | Viewed by 1761
Abstract
Numerous papers report the occurrence of head and neck tumors in interventional radiology (IR) physicians. Recently, appropriate dosimetry and protection have become much more important. To accomplish these, first, we should accurately understand how the brain is exposed. We assessed the dose distribution [...] Read more.
Numerous papers report the occurrence of head and neck tumors in interventional radiology (IR) physicians. Recently, appropriate dosimetry and protection have become much more important. To accomplish these, first, we should accurately understand how the brain is exposed. We assessed the dose distribution of the head and clarified the relationship between head exposure and brain dose. We used eight radiophotoluminescence dosimeters (RPLDs), two at the surface of the eyes and six inside the phantom head. We conducted measurements with three kinds of irradiation fields: one irradiated the whole head, the second irradiated the brain region, and the third irradiated the soft tissue of the face. The cranial bone reduced the brain dose to less than half the skin dose: about 48% at the front and less than 9% at the back of the brain. Due to the brain exposure, the soft tissues were slightly exposed to the scatter radiation from the cranial bone. We revealed the dose distribution of the head and the influence of the scatter radiation from the cranial bone and the soft tissues of the face. There are two kinds of scatter radiation: from the cranial bone to the soft tissue of the face, and from the soft tissue to the brain. Although the influence of these sources of scatter radiation is not significant, the relationship between brain exposure and the occurrence of head and neck tumors is still unclear. Therefore, some IR physicians should keep this in mind if they receive high levels of exposure in their daily practice. Full article
Show Figures

Figure 1

12 pages, 1634 KiB  
Article
Radiation Signature in Plasma Metabolome of Total-Body Irradiated Nonhuman Primates and Clinical Patients
by Ales Tichy, Alana D. Carpenter, Yaoxiang Li, Gabriela Rydlova, Pavel Rehulka, Marketa Markova, Marcela Milanova, Vojtech Chmil, Amrita K. Cheema and Vijay K. Singh
Int. J. Mol. Sci. 2024, 25(17), 9208; https://doi.org/10.3390/ijms25179208 - 25 Aug 2024
Cited by 2 | Viewed by 1403
Abstract
In the last decade, geopolitical instability across the globe has increased the risk of a large-scale radiological event, when radiation biomarkers would be needed for an effective triage of an irradiated population. Ionizing radiation elicits a complex response in the proteome, genome, and [...] Read more.
In the last decade, geopolitical instability across the globe has increased the risk of a large-scale radiological event, when radiation biomarkers would be needed for an effective triage of an irradiated population. Ionizing radiation elicits a complex response in the proteome, genome, and metabolome and hence can be leveraged as rapid and sensitive indicators of irradiation-induced damage. We analyzed the plasma of total-body irradiated (TBI) leukemia patients (n = 24) and nonhuman primates (NHPs; n = 10) before and 24 h after irradiation, and we performed a global metabolomic study aiming to provide plasma metabolites as candidate radiation biomarkers for biological dosimetry. Peripheral blood samples were collected according to the appropriate ethical approvals, and metabolites were extracted and analyzed by liquid chromatography mass spectrometry. We identified an array of metabolites significantly altered by irradiation, including bilirubin, cholesterol, and 18-hydroxycorticosterone, which were detected in leukemia patients and NHPs. Pathway analysis showed overlapping perturbations in steroidogenesis, porphyrin metabolism, and steroid hormone biosynthesis and metabolism. Additionally, we observed dysregulation in bile acid biosynthesis and tyrosine metabolism in the TBI patient cohort. This investigation is, to our best knowledge, among the first to provide valuable insights into a comparison between human and NHP irradiation models. The findings from this study could be leveraged for translational biological dosimetry. Full article
(This article belongs to the Collection Feature Paper Collection in Biochemistry)
Show Figures

Figure 1

20 pages, 17243 KiB  
Article
Microscopic and Macroscopic Characterization of Hydrogels Based on Poly(vinyl-alcohol)–Glutaraldehyde Mixtures for Fricke Gel Dosimetry
by Silvia Locarno, Paolo Arosio, Francesca Curtoni, Marco Piazzoni, Emanuele Pignoli and Salvatore Gallo
Gels 2024, 10(3), 172; https://doi.org/10.3390/gels10030172 - 28 Feb 2024
Cited by 12 | Viewed by 2317
Abstract
In recent decades, hydrogels have emerged as innovative soft materials with widespread applications in the medical and biomedical fields, including drug delivery, tissue engineering, and gel dosimetry. In this work, a comprehensive study of the macroscopic and microscopic properties of hydrogel matrices based [...] Read more.
In recent decades, hydrogels have emerged as innovative soft materials with widespread applications in the medical and biomedical fields, including drug delivery, tissue engineering, and gel dosimetry. In this work, a comprehensive study of the macroscopic and microscopic properties of hydrogel matrices based on Poly(vinyl-alcohol) (PVA) chemically crosslinked with Glutaraldehyde (GTA) was reported. Five different kinds of PVAs differing in molecular weight and degree of hydrolysis were considered. The local microscopic organization of the hydrogels was studied through the use of the 1H nuclear magnetic resonance relaxometry technique. Various macroscopic properties (gel fraction, water loss, contact angle, swelling degree, viscosity, and Young’s Modulus) were investigated with the aim of finding a correlation between them and the features of the hydrogel matrix. Additionally, an optical characterization was performed on all the hydrogels loaded with Fricke solution to assess their dosimetric behavior. The results obtained indicate that the degree of PVA hydrolysis is a crucial parameter influencing the structure of the hydrogel matrix. This factor should be considered for ensuring stability over time, a vital property in the context of potential biomedical applications where hydrogels act as radiological tissue-equivalent materials. Full article
(This article belongs to the Special Issue Gel Dosimetry (2nd Edition))
Show Figures

Figure 1

16 pages, 2950 KiB  
Review
Bench to Bedside Development of [18F]Fluoromethyl-(1,2-2H4)choline ([18F]D4-FCH)
by Amarnath Challapalli, Tara D. Barwick, Suraiya R. Dubash, Marianna Inglese, Matthew Grech-Sollars, Kasia Kozlowski, Henry Tam, Neva H. Patel, Mathias Winkler, Penny Flohr, Azeem Saleem, Amit Bahl, Alison Falconer, Johann S. De Bono, Eric O. Aboagye and Stephen Mangar
Molecules 2023, 28(24), 8018; https://doi.org/10.3390/molecules28248018 - 8 Dec 2023
Cited by 1 | Viewed by 2235
Abstract
Malignant transformation is characterised by aberrant phospholipid metabolism of cancers, associated with the upregulation of choline kinase alpha (CHKα). Due to the metabolic instability of choline radiotracers and the increasing use of late-imaging protocols, we developed a more stable choline radiotracer, [18 [...] Read more.
Malignant transformation is characterised by aberrant phospholipid metabolism of cancers, associated with the upregulation of choline kinase alpha (CHKα). Due to the metabolic instability of choline radiotracers and the increasing use of late-imaging protocols, we developed a more stable choline radiotracer, [18F]fluoromethyl-[1,2-2H4]choline ([18F]D4-FCH). [18F]D4-FCH has improved protection against choline oxidase, the key choline catabolic enzyme, via a 1H/2D isotope effect, together with fluorine substitution. Due to the promising mechanistic and safety profiles of [18F]D4-FCH in vitro and preclinically, the radiotracer has transitioned to clinical development. [18F]D4-FCH is a safe positron emission tomography (PET) tracer, with a favourable radiation dosimetry profile for clinical imaging. [18F]D4-FCH PET/CT in lung and prostate cancers has shown highly heterogeneous intratumoral distribution and large lesion variability. Treatment with abiraterone or enzalutamide in metastatic castrate-resistant prostate cancer patients elicited mixed responses on PET at 12–16 weeks despite predominantly stable radiological appearances. The sum of the weighted tumour-to-background ratios (TBRs-wsum) was associated with the duration of survival. Full article
(This article belongs to the Special Issue Radiopharmaceuticals)
Show Figures

Figure 1

10 pages, 256 KiB  
Protocol
Radiation Exposure in Endovascular Surgery According to Complexity: Protocol for a Prospective Observational Study
by Dorelly Tanayra Martinez Del Carmen, Pablo Saldaña Gutierrez, Ramon Vila Coll and Elena Iborra Ortega
Methods Protoc. 2023, 6(3), 49; https://doi.org/10.3390/mps6030049 - 10 May 2023
Viewed by 2110
Abstract
In the past decades, we have witnessed tremendous developments in endovascular surgery. Nowadays, highly complex procedures are performed by minimally invasive means. A key point is equipment improvement. Modern C-arms provide advanced imaging capabilities, facilitating endovascular navigation with an adequate open surgical environment. [...] Read more.
In the past decades, we have witnessed tremendous developments in endovascular surgery. Nowadays, highly complex procedures are performed by minimally invasive means. A key point is equipment improvement. Modern C-arms provide advanced imaging capabilities, facilitating endovascular navigation with an adequate open surgical environment. Nevertheless, radiation exposure remains an issue of concern. This study aims to analyze radiation used during endovascular procedures according to complexity, comparing a mobile X-ray system with a hybrid room (fixed X-ray system). This is an observational and prospective study based on a cohort of non-randomized patients treated by endovascular procedures in a Vascular Surgery department using two imaging systems. The study is planned for a 3-year duration with a recruitment period of 30 months (beginning 20 July 2021) and a 1-month follow-up period for each patient. This is the first prospective study designed to describe the radiation dose according to the complexity of the procedure. Another strength of this study is that radiologic variables are obtained directly from the C-arm and no additional measurements are required for feasibility benefit. The results from this study will help us determine the level of radiation in different endovascular procedures, in view of their complexity. Full article
(This article belongs to the Section Biomedical Sciences and Physiology)
10 pages, 2500 KiB  
Article
Application of a Portable Colorimeter for Reading a Radiochromic Film for On-Site Dosimetry
by Hiroshi Yasuda and Hikaru Yoshida
Appl. Sci. 2023, 13(8), 4761; https://doi.org/10.3390/app13084761 - 10 Apr 2023
Cited by 9 | Viewed by 2773
Abstract
Radiochromic films have widely been used for quality assurance (QA) in radiation therapy and have many advantageous features such as self-developing visible coloration, wide dose range and easiness to handle. These features have a good potential for application to other fields associated with [...] Read more.
Radiochromic films have widely been used for quality assurance (QA) in radiation therapy and have many advantageous features such as self-developing visible coloration, wide dose range and easiness to handle. These features have a good potential for application to other fields associated with high-dose radiation exposure, e.g., verification of various radiation sources used in industry and research, occupational radiation monitoring as a preparedness for radiological emergencies. One of the issues in such applications is the elaborate process of acquisition and analyses of the color image using a flatbed scanner and image processing software, which is desirably to be improved for achieving a practical on-site dosimetry. In the present study, a simple method for reading a radiochromic film by using a portable colorimeter (nix pro 2; abbreviated here “Nix”) was proposed and its feasibility for diagnostic X-rays was tested with a commercial radiochromic film (Gafchromic EBT-XD). It was found that the color intensities of red and green components of EBT-XD were successfully measured by Nix over a wide dose range up to 40 Gy. Though some angle dependence was observed, this error could be well averted by careful attention to the film direction in a reading process. According to these findings, it is expected that the proposed on-site dosimetry method of combining a radiochromic film and a portable colorimeter will be practically utilized in various occasions. Full article
Show Figures

Figure 1

20 pages, 5599 KiB  
Review
High Resolution and Automatable Cytogenetic Biodosimetry Using In Situ Telomere and Centromere Hybridization for the Accurate Detection of DNA Damage: An Overview
by Radhia M’Kacher, Bruno Colicchio, Steffen Junker, Elie El Maalouf, Leonhard Heidingsfelder, Andreas Plesch, Alain Dieterlen, Eric Jeandidier, Patrice Carde and Philippe Voisin
Int. J. Mol. Sci. 2023, 24(6), 5699; https://doi.org/10.3390/ijms24065699 - 16 Mar 2023
Cited by 9 | Viewed by 3132
Abstract
In the event of a radiological or nuclear accident, or when physical dosimetry is not available, the scoring of radiation-induced chromosomal aberrations in lymphocytes constitutes an essential tool for the estimation of the absorbed dose of the exposed individual and for effective triage. [...] Read more.
In the event of a radiological or nuclear accident, or when physical dosimetry is not available, the scoring of radiation-induced chromosomal aberrations in lymphocytes constitutes an essential tool for the estimation of the absorbed dose of the exposed individual and for effective triage. Cytogenetic biodosimetry employs different cytogenetic assays including the scoring of dicentrics, micronuclei, and translocations as well as analyses of induced premature chromosome condensation to define the frequency of chromosome aberrations. However, inherent challenges using these techniques include the considerable time span from sampling to result, the sensitivity and specificity of the various techniques, and the requirement of highly skilled personnel. Thus, techniques that obviate these challenges are needed. The introduction of telomere and centromere (TC) staining have successfully met these challenges and, in addition, greatly improved the efficiency of cytogenetic biodosimetry through the development of automated approaches, thus reducing the need for specialized personnel. Here, we review the role of the various cytogenetic dosimeters and their recent improvements in the management of populations exposed to genotoxic agents such as ionizing radiation. Finally, we discuss the emerging potentials to exploit these techniques in a wider spectrum of medical and biological applications, e.g., in cancer biology to identify prognostic biomarkers for the optimal triage and treatment of patients. Full article
(This article belongs to the Special Issue Effects of Ionizing Radiation in Cancer Radiotherapy)
Show Figures

Figure 1

17 pages, 5110 KiB  
Article
Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications
by Ibrahim Algain, Mehenna Arib, Said A. Farha Al-Said and Hossam Donya
Sensors 2023, 23(2), 1011; https://doi.org/10.3390/s23021011 - 16 Jan 2023
Cited by 4 | Viewed by 2576
Abstract
The production of thermoluminescence (TL) dosimeters fabricated from B2O3-CaF2-Al2O3-SiO2 doped with Cu and Pr for use in diagnostic radiology is the main goal of this research. The TL samples were synthesized via [...] Read more.
The production of thermoluminescence (TL) dosimeters fabricated from B2O3-CaF2-Al2O3-SiO2 doped with Cu and Pr for use in diagnostic radiology is the main goal of this research. The TL samples were synthesized via the melt-quench technique processed by melting the mixture at 1200 °C for 1 h, and, after cooling, the sample thus created was divided into two samples and retreated by heating for 2 h (referred to as TLV30) and for 15 h (referred to as TLV17). SEM and EDS analyses were performed on the TL samples to confirm the preparation process and to investigate the effects of irradiation dosimetry on the TL samples. Furthermore, the TL samples were irradiated with γ-rays using a 450 Ci 137Cs irradiator and variable X-ray beams (5–70 mGy). Two important diagnostic radiology applications were considered: CT (6–24 mGy) and mammography (2.72–10.8 mGy). Important dosimetric properties, such as the glow curves, reproducibility, dose–response linearity, energy dependence, minimum dose detectability and fading, were investigated for the synthetized samples (TLV17 and TLV30), the results of which were compared with the Harshaw TLD-100. The TLV17 dosimeter showed higher sensitivity than TLV30 in all applied irradiation procedures. The dose–response linearity coefficients of determination R2 for TLV17 were higher than TLD-100 and TLV30 in some applications and were almost equal in others. The reproducibility results of TLV17, TLV30 and TLD-100 were less than 5%, which is acceptable. On the other hand, the results of the fading investigations showed that, in general, TLV17 showed less fading than TLV30. Both samples showed a significant decrease in this regard after the first day, and then the signal variation became essentially stable though with a slight decrease until the eighth day. Therefore, it is recommended to read the TL dosimeters after 24 h, as with TLD-100. The SEM images confirmed the existence of crystallization, whilst the EDS spectra confirmed the presence of the elements used for preparation. Furthermore, we noticed that TLV17 had grown dense crystals that were larger in size compared to those of TLV30, which explains the higher sensitivity in TLV17. Overall, despite the fading, TLV17 showed greater radiation sensitivity and dose–response linearity compared with TLD-100. The synthetized TL samples showed their suitability for use as dosimeters in diagnostic radiology radiation dosimetry. Full article
(This article belongs to the Section Chemical Sensors)
Show Figures

Figure 1

11 pages, 3397 KiB  
Communication
Evaluation of a New Real-Time Dosimeter Sensor for Interventional Radiology Staff
by Kenshin Hattori, Yohei Inaba, Toshiki Kato, Masaki Fujisawa, Hikaru Yasuno, Ayumi Yamada, Yoshihiro Haga, Masatoshi Suzuki, Masayuki Zuguchi and Koichi Chida
Sensors 2023, 23(1), 512; https://doi.org/10.3390/s23010512 - 3 Jan 2023
Cited by 19 | Viewed by 3897
Abstract
In 2011, the International Commission on Radiological Protection (ICRP) recommended a significant reduction in the lens-equivalent radiation dose limit, thus from an average of 150 to 20 mSv/year over 5 years. In recent years, the occupational dose has been rising with the increased [...] Read more.
In 2011, the International Commission on Radiological Protection (ICRP) recommended a significant reduction in the lens-equivalent radiation dose limit, thus from an average of 150 to 20 mSv/year over 5 years. In recent years, the occupational dose has been rising with the increased sophistication of interventional radiology (IVR); management of IVR staff radiation doses has become more important, making real-time radiation monitoring of such staff desirable. Recently, the i3 real-time occupational exposure monitoring system (based on RaySafeTM) has replaced the conventional i2 system. Here, we compared the i2 and i3 systems in terms of sensitivity (batch uniformity), tube-voltage dependency, dose linearity, dose-rate dependency, and angle dependency. The sensitivity difference (batch uniformity) was approximately 5%, and the tube-voltage dependency was <±20% between 50 and 110 kV. Dose linearity was good (R2 = 1.00); a slight dose-rate dependency (~20%) was evident at very high dose rates (250 mGy/h). The i3 dosimeter showed better performance for the lower radiation detection limit compared with the i2 system. The horizontal and vertical angle dependencies of i3 were superior to those of i2. Thus, i3 sensitivity was higher over a wider angle range compared with i2, aiding the measurement of scattered radiation. Unlike the i2 sensor, the influence of backscattered radiation (i.e., radiation from an angle of 180°) was negligible. Therefore, the i3 system may be more appropriate in areas affected by backscatter. In the future, i3 will facilitate real-time dosimetry and dose management during IVR and other applications. Full article
(This article belongs to the Special Issue Feature Papers in Physical Sensors 2022)
Show Figures

Figure 1

Back to TopTop