Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (85)

Search Parameters:
Keywords = radiant heat efficiency

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
25 pages, 3590 KiB  
Article
Effectiveness of Firefighter Training for Indoor Intervention: Analysis of Temperature Profiles and Extinguishing Effectiveness
by Jan Hora
Fire 2025, 8(8), 304; https://doi.org/10.3390/fire8080304 - 1 Aug 2025
Viewed by 194
Abstract
This study assessed the effectiveness of stress-based cognitive-behavioral training compared to standard training in firefighters, emphasizing their ability to distribute extinguishing water and cool environments evenly during enclosure fires. Experiments took place at the Zbiroh training facility with two firefighter teams (Team A [...] Read more.
This study assessed the effectiveness of stress-based cognitive-behavioral training compared to standard training in firefighters, emphasizing their ability to distribute extinguishing water and cool environments evenly during enclosure fires. Experiments took place at the Zbiroh training facility with two firefighter teams (Team A with stress-based training and Team B with standard training) under realistic conditions. Using 58 thermocouples and 4 radiometers, temperature distribution and radiant heat flux were measured to evaluate water distribution efficiency and cooling performance during interventions. Team A consistently achieved temperature reductions of approximately 320 °C in the upper layers and 250–400 °C in the middle layers, maintaining stable conditions, whereas Team B only achieved partial cooling, with upper-layer temperatures remaining at 750–800 °C. Additionally, Team A recorded lower radiant heat flux densities (e.g., 20.74 kW/m2 at 0°) compared to Team B (21.81 kW/m2), indicating more effective water application and adaptability. The findings confirm that stress-based training enhances firefighters’ operational readiness and their ability to distribute water effectively during interventions. This skill is essential for safer and effective management of indoor fires under extreme conditions. This study supports the inclusion of stress-based and scenario-based training in firefighter education to enhance safety and operational performance. Full article
Show Figures

Figure 1

39 pages, 5325 KiB  
Review
Mechanical Ventilation Strategies in Buildings: A Comprehensive Review of Climate Management, Indoor Air Quality, and Energy Efficiency
by Farhan Lafta Rashid, Mudhar A. Al-Obaidi, Najah M. L. Al Maimuri, Arman Ameen, Ephraim Bonah Agyekum, Atef Chibani and Mohamed Kezzar
Buildings 2025, 15(14), 2579; https://doi.org/10.3390/buildings15142579 - 21 Jul 2025
Viewed by 669
Abstract
As the demand for energy-efficient homes continues to rise, the importance of advanced mechanical ventilation systems in maintaining indoor air quality (IAQ) has become increasingly evident. However, challenges related to energy balance, IAQ, and occupant thermal comfort persist. This review examines the performance [...] Read more.
As the demand for energy-efficient homes continues to rise, the importance of advanced mechanical ventilation systems in maintaining indoor air quality (IAQ) has become increasingly evident. However, challenges related to energy balance, IAQ, and occupant thermal comfort persist. This review examines the performance of mechanical ventilation systems in regulating indoor climate, improving air quality, and minimising energy consumption. The findings indicate that demand-controlled ventilation (DCV) can enhance energy efficiency by up to 88% while maintaining CO2 concentrations below 1000 ppm during 76% of the occupancy period. Heat recovery systems achieve efficiencies of nearly 90%, leading to a reduction in heating energy consumption by approximately 19%. Studies also show that employing mechanical rather than natural ventilation in schools lowers CO2 levels by 20–30%. Nevertheless, occupant misuse or poorly designed systems can result in CO2 concentrations exceeding 1600 ppm in residential environments. Hybrid ventilation systems have demonstrated improved thermal comfort, with predicted mean vote (PMV) values ranging from –0.41 to 0.37 when radiant heating is utilized. Despite ongoing technological advancements, issues such as system durability, user acceptance, and adaptability across climate zones remain. Smart, personalized ventilation strategies supported by modern control algorithms and continuous monitoring are essential for the development of resilient and health-promoting buildings. Future research should prioritize the integration of renewable energy sources and adaptive ventilation controls to further optimise system performance. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

35 pages, 2895 KiB  
Review
Ventilated Facades for Low-Carbon Buildings: A Review
by Pinar Mert Cuce and Erdem Cuce
Processes 2025, 13(7), 2275; https://doi.org/10.3390/pr13072275 - 17 Jul 2025
Viewed by 643
Abstract
The construction sector presently consumes about 40% of global energy and generates 36% of CO2 emissions, making facade retrofits a priority for decarbonising buildings. This review clarifies how ventilated facades (VFs), wall assemblies that interpose a ventilated air cavity between outer cladding [...] Read more.
The construction sector presently consumes about 40% of global energy and generates 36% of CO2 emissions, making facade retrofits a priority for decarbonising buildings. This review clarifies how ventilated facades (VFs), wall assemblies that interpose a ventilated air cavity between outer cladding and the insulated structure, address that challenge. First, the paper categorises VFs by structural configuration, ventilation strategy and functional control into four principal families: double-skin, rainscreen, hybrid/adaptive and active–passive systems, with further extensions such as BIPV, PCM and green-wall integrations that couple energy generation or storage with envelope performance. Heat-transfer analysis shows that the cavity interrupts conductive paths, promotes buoyancy- or wind-driven convection, and curtails radiative exchange. Key design parameters, including cavity depth, vent-area ratio, airflow velocity and surface emissivity, govern this balance, while hybrid ventilation offers the most excellent peak-load mitigation with modest energy input. A synthesis of simulation and field studies indicates that properly detailed VFs reduce envelope cooling loads by 20–55% across diverse climates and cut winter heating demand by 10–20% when vents are seasonally managed or coupled with heat-recovery devices. These thermal benefits translate into steadier interior surface temperatures, lower radiant asymmetry and fewer drafts, thereby expanding the hours occupants remain within comfort bands without mechanical conditioning. Climate-responsive guidance emerges in tropical and arid regions, favouring highly ventilated, low-absorptance cladding; temperate and continental zones gain from adaptive vents, movable insulation or PCM layers; multi-skin adaptive facades promise balanced year-round savings by re-configuring in real time. Overall, the review demonstrates that VFs constitute a versatile, passive-plus platform for low-carbon buildings, simultaneously enhancing energy efficiency, durability and indoor comfort. Future advances in smart controls, bio-based materials and integrated energy-recovery systems are poised to unlock further performance gains and accelerate the sector’s transition to net-zero. Emerging multifunctional materials such as phase-change composites, nanostructured coatings, and perovskite-integrated systems also show promise in enhancing facade adaptability and energy responsiveness. Full article
(This article belongs to the Special Issue Sustainable Development of Energy and Environment in Buildings)
Show Figures

Figure 1

21 pages, 3617 KiB  
Article
Numerical and Experimental Study of Enhanced Heat Dissipation Performance of Graphene-Coated Heating Cables
by Zhenzhen Chen, Chenchen Xu, Feilong Zhang and Tao Sun
Coatings 2025, 15(7), 777; https://doi.org/10.3390/coatings15070777 - 30 Jun 2025
Viewed by 324
Abstract
Low-temperature radiant heating systems utilizing heating cables face challenges including low heat dissipation efficiency and high energy consumption, hindering widespread application. Graphene coatings, characterized by high thermal conductivity and far-infrared radiation properties, offer a novel approach to enhance cable heat dissipation efficiency. This [...] Read more.
Low-temperature radiant heating systems utilizing heating cables face challenges including low heat dissipation efficiency and high energy consumption, hindering widespread application. Graphene coatings, characterized by high thermal conductivity and far-infrared radiation properties, offer a novel approach to enhance cable heat dissipation efficiency. This study systematically investigates the effects of coating position, thickness, and ambient temperature on cable heat dissipation using numerical simulations and experiments. A three-dimensional heat transfer model of the heating cable was established using Fluent software (2022R1). The radiation heat transfer equation was solved using the Discrete Ordinates (DO) model, and the coating position and thickness parameters were optimized. The reliability of the simulation results was validated using a temperature-rise experimental platform. The results indicate that graphene coatings significantly improve the heat dissipation performance of cables. Under optimal parameters (coating thickness: 100 μm, coating position: aluminum fin surface, initial temperature: 5 °C), the heat flux increased by approximately 26%, aluminum fin surface temperature decreased to 41.5 °C, and experimental temperature-rise efficiency improved by nearly 50%. The discrepancy between simulated and experimental results was within 8.5%. However, when coating thickness exceeded 100 μm, interfacial thermal resistance increased, reducing heat dissipation efficiency. Additionally, higher ambient temperatures suppressed heat dissipation. These findings provide a theoretical basis for optimizing the energy efficiency of low-temperature radiant heating systems. Full article
(This article belongs to the Section Surface Characterization, Deposition and Modification)
Show Figures

Figure 1

15 pages, 4884 KiB  
Article
Influence of Cable Spacing on Flame Interaction and Combustion Characteristics of Parallel Thermoplastic Cables
by Rongshui Qin, Xiangxiang Zhang, Yuyao Li, Jinchao Wei, Chao Ding and Yan Jiao
Fire 2025, 8(7), 258; https://doi.org/10.3390/fire8070258 - 30 Jun 2025
Viewed by 353
Abstract
Cable fires pose significant risks to electrical infrastructures, and cable spacing plays a crucial role in influencing fire propagation behaviors. In this study, the combustion characteristics of two parallel thermoplastic cables under varying spacing conditions were systematically investigated through controlled experiments. Key parameters, [...] Read more.
Cable fires pose significant risks to electrical infrastructures, and cable spacing plays a crucial role in influencing fire propagation behaviors. In this study, the combustion characteristics of two parallel thermoplastic cables under varying spacing conditions were systematically investigated through controlled experiments. Key parameters, including flame merging behavior, flame morphology, mass loss rate, flame spread rate, flame temperature, and radiant heat flux, were analyzed. The results revealed that cable spacing critically affects flame interaction, with three distinct flame merging modes—continuous merging, intermittent merging, and non-merging—identified as spacing increases. A critical spacing of 2.5 mm was found, at which the flame spread rate and mass loss rate reached their maximum, approximately 1.7 times higher than that of a single cable. At intermediate spacings (2.5–12.5 mm), enhanced flame interaction and radiative feedback significantly intensified combustion, leading to higher flame temperatures and radiant heat peaks. Conversely, insufficient oxygen supply at zero spacing and reduced flame interaction at large spacings (15 mm) resulted in diminished combustion efficiency. These findings highlight the importance of cable spacing as a key design parameter for mitigating fire hazards in electrical installations, providing valuable insights for fire safety engineering and risk assessment. Full article
(This article belongs to the Special Issue Cable and Wire Fires)
Show Figures

Figure 1

20 pages, 2551 KiB  
Article
Theoretical Study on Impact of Solar Radiation Heat Gain on Thermal Comfort and Energy Efficiency in Glass Curtain Wall Buildings Based on PMV Index
by Haoyu Chen, Jinzhe Nie, Yuzhe Liu and Yuelin Li
Buildings 2025, 15(13), 2228; https://doi.org/10.3390/buildings15132228 - 25 Jun 2025
Viewed by 564
Abstract
With rapid global urbanization, glass curtain wall buildings have been widely adopted due to aesthetics and natural lighting. However, during summer time, intense solar radiation leads to significant indoor heat gain, which adversely affect thermal comfort and energy efficiency. The conventional air conditioning [...] Read more.
With rapid global urbanization, glass curtain wall buildings have been widely adopted due to aesthetics and natural lighting. However, during summer time, intense solar radiation leads to significant indoor heat gain, which adversely affect thermal comfort and energy efficiency. The conventional air conditioning systems are typically equipped with a cooling capacity sufficient to maintain an indoor air temperature at the design values specified in the Design standard for energy efficiency of public buildings, which fails to account for the effects of radiation temperature, potentially resulting in reduced thermal comfort and energy inefficiency. By integrating the Thermal Comfort Tool to calculate the PMV index, this study evaluates the affection of solar heat gain on indoor occupants’ thermal comfort and proposes an optimized air temperature control strategy to realize thermal comfort. Based on the dynamic air temperature strategy, an energy consumption model is developed to evaluate the affection of solar radiation on energy consumption for glass curtain wall buildings based on the PMV index. The synergistic effects of shading measures are then evaluated. This study conducts simulation analysis using an office building with a glass curtain wall located in Beijing as a case study. When accounting for radiant heat gain, a significant portion of the time (53.89%) fall outside the thermal comfort range, even when the air conditioning is set to the designated temperature. To maintain thermal comfort, the air conditioning temperature must be lowered by 1.4–3.5 °C, resulting in a 28.08% increase in energy consumption. To address this issue, this study finds that installing interior shading can reduce radiant heat gain. Under the same thermal comfort conditions, the required air temperature reduction is only 0.8–2.1 °C, leading to a 24.26% reduction in energy consumption compared to the case without interior shading. Full article
Show Figures

Figure 1

10 pages, 3553 KiB  
Proceeding Paper
Simulation of Staged Combustion Function in Double P-Type Radiant Tubes
by Chien-Chou Lin, Tsai-Jung Chen, Wei-Lin Cheng and Chien-Hsiung Tsai
Eng. Proc. 2025, 92(1), 94; https://doi.org/10.3390/engproc2025092094 - 9 Jun 2025
Viewed by 249
Abstract
Radiant tubes are essential in industrial furnaces, with thermal efficiency often improved by extending the tube length which reduces durability and complicates production. Integrating finned-tube heat exchangers enhances durability without lengthening tubes but increases NOx emissions. Using staged combustion with four nozzle [...] Read more.
Radiant tubes are essential in industrial furnaces, with thermal efficiency often improved by extending the tube length which reduces durability and complicates production. Integrating finned-tube heat exchangers enhances durability without lengthening tubes but increases NOx emissions. Using staged combustion with four nozzle designs, the emission of NOx is reduced as smaller nozzle diameters lower flame temperatures and suppress NOx production. U-shaped tubes without heat exchangers require higher flame temperatures and NOx emissions 20 times more than double P-type tubes. Full article
(This article belongs to the Proceedings of 2024 IEEE 6th Eurasia Conference on IoT, Communication and Engineering)
Show Figures

Figure 1

29 pages, 2457 KiB  
Article
Energy and Exergy Analysis of a Photovoltaic-Thermal Geothermal Heat Pump Coupled with Radiant Ceiling and Fresh Air System
by Yaolin Lin, Zhenyan Bu, Wei Yang, Melissa Chan, Lin Tian and Mingqi Dai
Energies 2025, 18(11), 2715; https://doi.org/10.3390/en18112715 - 23 May 2025
Viewed by 382
Abstract
This paper presents energy and exergy studies on a photovoltaic-thermal solar-assisted geothermal heat pump coupled with a radiant ceiling system. The system utilizes renewable solar and geothermal energy. It has an independent fresh air unit that provides clean air to the space. The [...] Read more.
This paper presents energy and exergy studies on a photovoltaic-thermal solar-assisted geothermal heat pump coupled with a radiant ceiling system. The system utilizes renewable solar and geothermal energy. It has an independent fresh air unit that provides clean air to the space. The computer model of the system was developed under the TRNSYST environment and validated with experimental results from open literature. Distribution of the energy consumption and exergy loss of the system were analyzed. It was found that the heat pump unit consumes the largest amount of energy while the transmission and distribution system has the highest exergy loss. Under optimized operating conditions, i.e., both demand side circulation flow and source side circulation flow are maintained at 65% of the design flow rate (design loop water temperature difference of 7.0 °C), the average exergy efficiency of the whole system was found to be 37.56%, which achieves an accumulative exergy loss reduction of 16.5% compared with 100% design flow rate condition during cooling season. The optimal bearing load ratio of the ground source heat pump vs. photovoltaic-thermal system in the heating season was found to be 67%. Full article
(This article belongs to the Section G: Energy and Buildings)
Show Figures

Figure 1

26 pages, 8225 KiB  
Article
Dynamic Simulation of Solar-Assisted Medium-Depth Ground Heat Exchanger Direct Heating System
by Le Chang, Lingjun Kong, Yangyang Jing, Wenshuo Zhang, Sifang Fu, Xueming Lu, Haiqing Yao, Xiaona Xie and Ping Cui
Buildings 2025, 15(10), 1690; https://doi.org/10.3390/buildings15101690 - 16 May 2025
Viewed by 310
Abstract
The global challenges of rising energy consumption and carbon emissions underscore the urgent need for efficient and sustainable heating solutions in the building sector. The implementation of high-performance buildings that envelope insulation and the increasing adoption of low-temperature radiant heating systems have significantly [...] Read more.
The global challenges of rising energy consumption and carbon emissions underscore the urgent need for efficient and sustainable heating solutions in the building sector. The implementation of high-performance buildings that envelope insulation and the increasing adoption of low-temperature radiant heating systems have significantly reduced the water temperature required from heat sources, enabling greater compatibility with renewable energy systems. In this study, we propose a renewable energy heating system incorporating a solar-assisted medium-depth ground heat exchanger (MDGHE). A dynamic simulation model of the solar-assisted MDGHE system was developed in TRNSYS, featuring a novel MDGHE module specifically developed to improve simulation accuracy. A case study of a residential building in China was conducted to evaluate the performance of the proposed system. The simulation results demonstrate that while the standalone MDGHE covers 71.9% of the building’s heating demand, integrating solar collectors with the MDGHE can increase this coverage to 99.9%, enabling full compliance with heating requirements without relying on conventional heat pumps. The results revealed that the system’s COP reached 9.26. Compared with the traditional medium-depth ground source heat pump system with the COP of 4.84, the energy efficiency of this system has been enhanced by 47.7%. A static payback period of 7 years has been obtained compared with the cost of central heating service for residential buildings. These findings highlight the potential of solar-geothermal hybrid systems as a sustainable alternative to traditional heating methods. Full article
Show Figures

Figure 1

15 pages, 5183 KiB  
Article
Integrating Radiant Cooling Ceilings with Ternary PCM Thermal Storage: A Synergistic Approach for Enhanced Energy Efficiency in Photovoltaic-Powered Buildings
by Zhuoyi Ling, Tianhong Zheng, Qinghua Lv, Yuehong Su, Hui Lv and Saffa Riffat
Energies 2025, 18(9), 2237; https://doi.org/10.3390/en18092237 - 28 Apr 2025
Viewed by 511
Abstract
Traditional photovoltaic-powered forced air-cooling systems face significant challenges in balancing energy efficiency and thermal comfort due to temperature sensitivity, mechanical ventilation energy consumption, and spatial constraints. This study aims to enhance building energy efficiency by integrating a radiant cooling ceiling (RCC) with a [...] Read more.
Traditional photovoltaic-powered forced air-cooling systems face significant challenges in balancing energy efficiency and thermal comfort due to temperature sensitivity, mechanical ventilation energy consumption, and spatial constraints. This study aims to enhance building energy efficiency by integrating a radiant cooling ceiling (RCC) with a phase change material (PCM) thermal storage system, addressing the limitations of traditional photovoltaic-powered cooling systems through optimized material design and dynamic energy management. A ternary PCM mixture (glycerol–alcohol–water) was optimized using differential scanning calorimetry (DSC), demonstrating superior latent heat storage (361.66 J/g) and phase transition temperature (1.91 °C) in the selected “Slushy Ice” formulation. A 3D transient thermal model and experimental validation revealed that the RCC system achieved 57% energy savings under quasi-steady operation, with radiative heat transfer contributing 55% of total cooling capacity. The system dynamically stores cold energy during peak photovoltaic generation and releases it via RCC during low-power periods, resolving the “cooling energy consumption paradox”. Key challenges, including PCM cycling stability and thermal response time mismatches, were identified, with future research directions emphasizing multi-scale simulations and intelligent encapsulation. This work provides a viable pathway for improving building energy efficiency while maintaining thermal comfort and for improving building energy efficiency in temperate zones, with future extensions to arid and tropical climates requiring targeted material and system optimizations. Full article
(This article belongs to the Section J1: Heat and Mass Transfer)
Show Figures

Figure 1

25 pages, 8831 KiB  
Article
Design and Analysis of a Two-Stage Cascade System for Heating and Hot Water Production in Nearly Zero-Energy Buildings Using Thermoelectric Technology
by Javier Ordóñez, Sergio Díaz de Garayo, Álvaro Martínez, Fernando Algarra and David Astrain
Buildings 2024, 14(12), 3988; https://doi.org/10.3390/buildings14123988 - 16 Dec 2024
Viewed by 1037
Abstract
This paper proposes an innovative system that integrates two thermoelectric heat pumps (one air–water and the other water–water) with two thermal storage tanks at different temperatures to provide heating and domestic hot water to a 73.3 m2 passive-house-certified dwelling in Pamplona (Spain). [...] Read more.
This paper proposes an innovative system that integrates two thermoelectric heat pumps (one air–water and the other water–water) with two thermal storage tanks at different temperatures to provide heating and domestic hot water to a 73.3 m2 passive-house-certified dwelling in Pamplona (Spain). The air–water thermoelectric heat pump extracts heat from the ambient air and provides heat to a tank at intermediate temperature, which supplies water to a radiant floor. The water–water heat pump takes heat from this tank and provides heat to the other tank, at higher temperature, which supplies domestic hot water. The system performance and comfort conditions are computationally analyzed during the month of January under the climate of Pamplona and under different European climates. The COP of the system lays between 1.3 and 1.7, depending on the climate, because of the low COP of the air–water thermoelectric heat pump. However, it is able to provide water for the radiant floor and to maintain the temperature of the dwelling above 20 °C 99.8% of the time. Moreover, it provides domestic hot water at a temperature above 43 °C 99.9% of the time. Noteworthy is the fact that the water–water heat pump presents a COP close to 4, which opens up the possibilities of working in combination with more efficient heat pumps for the first stage. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

27 pages, 21860 KiB  
Article
Photovoltaic Integrated Shading Devices in the Retrofitting of Existing Buildings on Chinese Campuses Within a Regional Context
by Zhiwen Cai, Wenhao Zhang, Jiajian Chen and Ping Su
Buildings 2024, 14(11), 3577; https://doi.org/10.3390/buildings14113577 - 11 Nov 2024
Cited by 2 | Viewed by 1272
Abstract
Retrofitting existing buildings to be more energy-efficient is a tremendous contribution to the sustainability of society. The application of photovoltaic integrated shading devices (PVSDs) accords with this ambition by blocking out unwanted radiant heat gain and generating clean electricity. The deployment of PVSDs [...] Read more.
Retrofitting existing buildings to be more energy-efficient is a tremendous contribution to the sustainability of society. The application of photovoltaic integrated shading devices (PVSDs) accords with this ambition by blocking out unwanted radiant heat gain and generating clean electricity. The deployment of PVSDs needs sensible design strategies to optimize the production of renewable energy while retaining the aesthetic quality of the built-up environment, especially in historic campuses. The concept was tested in a case study of buildings in South China University of Technology (SCUT) using Ladybug 1.4.0 and PVsyst 7.2, utilizing the existing “Xia’s shading” design method in historical environments and optimizing the design from the perspective of photovoltaic performance. Firstly, the photovoltaic (PV) panels were integrated as architectural components, and the parameters were incorporated into a mathematical equation based on “Xia’s shading” design method. This was followed by the assessment of the solar energy harvesting potential based on simulated annual solar irradiation values. Lastly, the PV panels’ solar irradiation potential under these different parameters was shown in figures to identify the optimum parameters combination for PVSD applications. The proposed methodology could evolve as a design tool and thus further assist in promoting the large-scale adoption of PVSDs in retrofit projects. Full article
(This article belongs to the Section Building Energy, Physics, Environment, and Systems)
Show Figures

Figure 1

24 pages, 6928 KiB  
Article
Adjustable PV Slats for Energy Efficiency and Comfort Improvement of a Radiantly Cooled Office Room in Tropical Climate
by Pipat Chaiwiwatworakul
Buildings 2024, 14(10), 3282; https://doi.org/10.3390/buildings14103282 - 17 Oct 2024
Cited by 1 | Viewed by 947
Abstract
This paper investigated an application of adjustable photovoltaic (PV) slats to improve the thermal performance of an exposed glazing window and sequentially enhance the energy efficiency and thermal comfort of an office room. Solar radiation and longwave heat gains from a window fitted [...] Read more.
This paper investigated an application of adjustable photovoltaic (PV) slats to improve the thermal performance of an exposed glazing window and sequentially enhance the energy efficiency and thermal comfort of an office room. Solar radiation and longwave heat gains from a window fitted with PV slats were measured through experiments conducted in an outdoor chamber cooled by a radiant ceiling system. The daylight level at the workplane was also measured inside the chamber. A transient thermal model was developed and validated against experimental data. Using the experimental chamber as a demonstration case, the model revealed that adjusting the slats monthly to fully block direct sunlight could reduce the electrical energy use by 67% compared to a typical office with heat reflective glass windows. However, the electricity generated by the PV slats contributed a minor portion of the overall energy savings. To assess the thermal comfort impact of the PV slats in the room with the radiant cooling, this study utilized radiation asymmetry criteria from ASHRAE Standard 55. Simulations showed that the PV slat-shaded glazing window resulted in a lower asymmetric plane radiant temperature than the unshaded window of heat reflective glass. The adjustable slat system reduced the risk of local discomfort for occupants working near the window in the radiantly cooled office room. Full article
Show Figures

Figure 1

21 pages, 10146 KiB  
Article
Evaluating the Effectiveness of Cellulose-Based Surfactants in Expandable Graphite Wood Coatings
by Tereza Jurczyková, Elena Kmeťová, František Kačík, Martin Lexa and Daniel Dědič
Polymers 2024, 16(19), 2832; https://doi.org/10.3390/polym16192832 - 7 Oct 2024
Cited by 2 | Viewed by 1792
Abstract
This study deals with the design of modern environmentally friendly and non-toxic flame retardants based on expandable graphite 25 K + 180 (EG) modified by cellulose ethers (Lovose TS 20, Tylose MH 300, Klucel H) and nanocellulose (CNC) that are biocompatible with wood [...] Read more.
This study deals with the design of modern environmentally friendly and non-toxic flame retardants based on expandable graphite 25 K + 180 (EG) modified by cellulose ethers (Lovose TS 20, Tylose MH 300, Klucel H) and nanocellulose (CNC) that are biocompatible with wood and, therefore, are a prerequisite for an effective surfactant for connecting EG to wood. The effectiveness of the formulations and surfactants was verified using a radiant heat source test. The cohesion of the coating to the wood surface and the cohesion of the expanded graphite layer were also assessed. The fire efficiency of the surfactants varied greatly. Still, in combination with EG, they were all able to provide sufficient protection—the total relative mass loss was, in all cases, in the range of 7.38–7.83% (for untreated wood it was 88.67 ± 1.33%), and the maximum relative burning rate decreased tenfold compared to untreated wood, i.e., to 0.04–0.05%·s−1. Good results were achieved using Klucel H + EG and CNC + EG formulations. Compared to Klucel H, CNC provides significantly better cohesion of the expanded layer, but its high price increases the cost of the fireproof coating. Full article
Show Figures

Figure 1

27 pages, 3505 KiB  
Article
A Novel Direct-Expansion Radiant Floor System Utilizing Water (R-718) for Cooling and Heating
by Fadi Alsouda, Nick S. Bennett, Suvash C. Saha and Mohammad S. Islam
Energies 2024, 17(17), 4520; https://doi.org/10.3390/en17174520 - 9 Sep 2024
Cited by 1 | Viewed by 1235
Abstract
While forced-air convective systems remain the predominant method for heating and cooling worldwide, radiant cooling and heating systems are emerging as a more efficient alternative. Current radiant cooling systems primarily rely on hydronic chilled water systems. This study introduces direct-expansion radiant cooling as [...] Read more.
While forced-air convective systems remain the predominant method for heating and cooling worldwide, radiant cooling and heating systems are emerging as a more efficient alternative. Current radiant cooling systems primarily rely on hydronic chilled water systems. This study introduces direct-expansion radiant cooling as a novel technique that could enhance the efficiency of radiant cooling and reduce its environmental impact. Water (R-718) has been tested as a refrigerant due to its favorable thermodynamic properties and environmental advantages; however, to the author’s knowledge, it has yet to be tested in direct-expansion radiant cooling. This research investigated several refrigerants, including water (R-718), ammonia (R-717), R-410a, R-32, R-134a, and R-1234yf, for this application. The findings indicate that water demonstrates efficiency comparable to other non-natural refrigerants, making it a promising candidate, given its favorable thermodynamic properties and substantial environmental benefits. Despite challenges such as a high compression ratio necessitating multi-stage compression, a high compressor discharge temperature exceeding 300 °C and requiring specialized blade materials, and a high suction volume flow rate, direct-expansion radiant cooling operates within a different temperature range. Consequently, the compressor discharge temperature can be reduced to 176 °C, and the compression ratio can be lowered to approximately 3.5, making water a more viable refrigerant option for this application. Full article
(This article belongs to the Section J: Thermal Management)
Show Figures

Figure 1

Back to TopTop