Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (9)

Search Parameters:
Keywords = miniature thread

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
24 pages, 943 KB  
Review
A Review on AI Miniaturization: Trends and Challenges
by Bin Tang, Shengzhi Du and Antonie Johan Smith
Appl. Sci. 2025, 15(20), 10958; https://doi.org/10.3390/app152010958 - 12 Oct 2025
Viewed by 751
Abstract
Artificial intelligence (AI) often suffers from high energy consumption and complex deployment in resource-constrained environments, leading to a structural mismatch between capability and deployability. This review takes two representative scenarios—energy-first and performance-first—as the main thread, systematically comparing cloud, edge, and fog/cloudlet/mobile edge computing [...] Read more.
Artificial intelligence (AI) often suffers from high energy consumption and complex deployment in resource-constrained environments, leading to a structural mismatch between capability and deployability. This review takes two representative scenarios—energy-first and performance-first—as the main thread, systematically comparing cloud, edge, and fog/cloudlet/mobile edge computing (MEC)/micro data center (MDC) architectures. Based on a standardized literature search and screening process, three categories of miniaturization strategies are distilled: redundancy compression (e.g., pruning, quantization, and distillation), knowledge transfer (e.g., distillation and parameter-efficient fine-tuning), and hardware–software co-design (e.g., neural architecture search (NAS), compiler-level, and operator-level optimization). The purposes of this review are threefold: (1) to unify the “architecture–strategy–implementation pathway” from a system-level perspective; (2) to establish technology–budget mapping with verifiable quantitative indicators; and (3) to summarize representative pathways for energy- and performance-prioritized scenarios, while highlighting current deficiencies in data disclosure and device-side validation. The findings indicate that, compared with single techniques, cross-layer combined optimization better balances accuracy, latency, and power consumption. Therefore, AI miniaturization should be regarded as a proactive method of structural reconfiguration for large-scale deployment. Future efforts should advance cross-scenario empirical validation and standardized benchmarking, while reinforcing hardware–software co-design. Compared with existing reviews that mostly focus on a single dimension, this review proposes a cross-level framework and design checklist, systematizing scattered optimization methods into reusable engineering pathways. Full article
Show Figures

Figure 1

10 pages, 1519 KB  
Article
Proof-of-Concept Quantitative Monitoring of Respiration Using Low-Energy Wearable Piezoelectric Thread
by Kenta Horie, Muhammad Salman Al Farisi, Yoshihiro Hasegawa, Miyoko Matsushima, Tsutomu Kawabe and Mitsuhiro Shikida
Electronics 2024, 13(23), 4577; https://doi.org/10.3390/electronics13234577 - 21 Nov 2024
Cited by 4 | Viewed by 2110
Abstract
Currently, wearable sensors can measure vital sign frequencies, such as respiration rate, but they fall short of providing quantitative data, such as respiratory tidal volume. Meanwhile, the airflow at the mouth carries both the frequency and quantitative respiratory signals. In this study, we [...] Read more.
Currently, wearable sensors can measure vital sign frequencies, such as respiration rate, but they fall short of providing quantitative data, such as respiratory tidal volume. Meanwhile, the airflow at the mouth carries both the frequency and quantitative respiratory signals. In this study, we propose a method to calibrate a wearable piezoelectric thread sensor placed on the chest using mouth airflow for accurate quantitative respiration monitoring. Prior to human trials, we introduced an artificial ventilator as a test subject. To validate the proposed concept, we embedded a miniaturized tube airflow sensor at the ventilator’s outlet, which simulates human respiration, and attached a wearable piezoelectric thread to the piston, which moves periodically to mimic human chest movement. The integrated output readings from the wearable sensor aligned with the airflow rate measurements, demonstrating its ability to accurately monitor not only respiration rate but also quantitative metrics such as respiratory volume. Finally, tidal volume measurement was demonstrated using the wearable piezoelectric thread. Full article
(This article belongs to the Section Electronic Materials, Devices and Applications)
Show Figures

Figure 1

13 pages, 523 KB  
Article
Spin Precession in the Gravity Wave Analogue Black Hole Spacetime
by Chandrachur Chakraborty and Banibrata Mukhopadhyay
Universe 2022, 8(3), 193; https://doi.org/10.3390/universe8030193 - 20 Mar 2022
Viewed by 2619
Abstract
It was predicted that the spin precession frequency of a stationary gyroscope shows various anomalies in the strong gravity regime if its orbit shrinks, and eventually, its precession frequency becomes arbitrarily high very close to the horizon of a rotating black hole. Considering [...] Read more.
It was predicted that the spin precession frequency of a stationary gyroscope shows various anomalies in the strong gravity regime if its orbit shrinks, and eventually, its precession frequency becomes arbitrarily high very close to the horizon of a rotating black hole. Considering the gravity waves of a flowing fluid with a vortex in a shallow basin, which acts as a rotating analogue black hole, one can observe the predicted strong gravity effect on the spin precession in the laboratory. Attaching a thread with the buoyant particles and anchoring it to the bottom of the fluid container with a short-length miniature chain, one can construct a simple local test gyroscope to measure the spin precession frequency in the vicinity of the gravity wave analogue black hole. The thread acts as the axis of the gyroscope. By regulating the orbital frequency of the test gyroscope, one can also measure the strong gravity Lense–Thirring effect and geodetic/de-Sitter effect with this experimental set-up as the special cases. For example, to measure the Lense–Thirring effect, the length of the miniature chain can be set to zero, so that the gyroscope becomes static. One can also measure the geodetic precession with this system by orbiting the test gyroscope in the so-called Keplerian frequency around the non-rotating analogue black hole that can be constructed by making the rotation of the fluid/vortex negligible compared to its radial velocity. Full article
(This article belongs to the Special Issue Analogue Gravity)
Show Figures

Figure 1

15 pages, 1707 KB  
Article
A Novel Miniaturized Biosensor for Monitoring Atlantic Salmon Swimming Activity and Respiratory Frequency
by Jelena Kolarevic, Josep Calduch-Giner, Åsa M. Espmark, Tor Evensen, Javier Sosa and Jaume Pérez-Sánchez
Animals 2021, 11(8), 2403; https://doi.org/10.3390/ani11082403 - 14 Aug 2021
Cited by 12 | Viewed by 5131
Abstract
The advanced development of sensor technologies has led to the emergence of fish biosensors that are currently used for research and commercial purposes. AEFishBIT is a miniaturized biosensor attached to fish operculum that measures physical activity and respiration frequencies. In this study, we [...] Read more.
The advanced development of sensor technologies has led to the emergence of fish biosensors that are currently used for research and commercial purposes. AEFishBIT is a miniaturized biosensor attached to fish operculum that measures physical activity and respiration frequencies. In this study, we determined the effect of the tagging method and evaluated the use of this biosensor to monitor post-smolt Atlantic salmon in a tank-based system. The use of piercing fish tag had a negative impact on the gills and operculum, unlike the identical protocols used in gilthead sea bream and European sea bass. In contrast, a surgical thread did not show any apparent tissue damage. Two data recording schedules were considered to monitor immediate early reaction to fish handling and light regime changes (records every 15 min over 2 days) or adaptation to new light conditions (records every 30 min over 4 days). Data showed stabilization of physical activity 8 h post-tagging, with different steady states for the activity/respiratory ratio after changes in light intensity that reflected a different time course adaptation to new light conditions. High correlations were observed between AEFishBIT and video recording data. These findings supported the use of AEFishBIT as a promising tool for smart sensing of Atlantic salmon. Full article
(This article belongs to the Special Issue Smart Farm)
Show Figures

Figure 1

13 pages, 2969 KB  
Article
Electrical Characterization of Conductive Threads for Textile Electronics
by Adrian K. Stavrakis, Mitar Simić and Goran M. Stojanović
Electronics 2021, 10(8), 967; https://doi.org/10.3390/electronics10080967 - 19 Apr 2021
Cited by 21 | Viewed by 5819
Abstract
In recent years, advancements in technology are constantly driving the miniaturization of electronic devices, not only in the renowned domain of Internet-of-Things but also in other fields such as that of flexible and textile electronics. As the latter forms a great ecosystem for [...] Read more.
In recent years, advancements in technology are constantly driving the miniaturization of electronic devices, not only in the renowned domain of Internet-of-Things but also in other fields such as that of flexible and textile electronics. As the latter forms a great ecosystem for new devices, that could be functional such as heating garments or sensory, many suppliers have already started producing and bringing to market conductive threads that can be used by researchers and the mass public for their work. However, to date, no extensive characterization has been carried out with respect to the electrical performance of such threads and that is what this article is aiming to amend. Four commercially available threads by two different suppliers were put under test, to establish their limitations in terms of maximum power handling, both continuous and instantaneous. They were subsequently examined at a microscopic scale as well, to verify any potential caveats in their design, and any hidden limitations. A preliminary profile for each of the four threads was successfully established. Full article
(This article belongs to the Special Issue Textile and Wearable Antennas)
Show Figures

Figure 1

37 pages, 4105 KB  
Review
Frontiers of Robotic Colonoscopy: A Comprehensive Review of Robotic Colonoscopes and Technologies
by Gastone Ciuti, Karolina Skonieczna-Żydecka, Wojciech Marlicz, Veronica Iacovacci, Hongbin Liu, Danail Stoyanov, Alberto Arezzo, Marcello Chiurazzi, Ervin Toth, Henrik Thorlacius, Paolo Dario and Anastasios Koulaouzidis
J. Clin. Med. 2020, 9(6), 1648; https://doi.org/10.3390/jcm9061648 - 31 May 2020
Cited by 91 | Viewed by 18642
Abstract
Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold standard of all population-based screening pathways around the world. Almost 60% of CRC deaths could be prevented with screening. However, colonoscopy attendance rates are affected by discomfort, fear [...] Read more.
Flexible colonoscopy remains the prime mean of screening for colorectal cancer (CRC) and the gold standard of all population-based screening pathways around the world. Almost 60% of CRC deaths could be prevented with screening. However, colonoscopy attendance rates are affected by discomfort, fear of pain and embarrassment or loss of control during the procedure. Moreover, the emergence and global thread of new communicable diseases might seriously affect the functioning of contemporary centres performing gastrointestinal endoscopy. Innovative solutions are needed: artificial intelligence (AI) and physical robotics will drastically contribute for the future of the healthcare services. The translation of robotic technologies from traditional surgery to minimally invasive endoscopic interventions is an emerging field, mainly challenged by the tough requirements for miniaturization. Pioneering approaches for robotic colonoscopy have been reported in the nineties, with the appearance of inchworm-like devices. Since then, robotic colonoscopes with assistive functionalities have become commercially available. Research prototypes promise enhanced accessibility and flexibility for future therapeutic interventions, even via autonomous or robotic-assisted agents, such as robotic capsules. Furthermore, the pairing of such endoscopic systems with AI-enabled image analysis and recognition methods promises enhanced diagnostic yield. By assembling a multidisciplinary team of engineers and endoscopists, the paper aims to provide a contemporary and highly-pictorial critical review for robotic colonoscopes, hence providing clinicians and researchers with a glimpse of the major changes and challenges that lie ahead. Full article
Show Figures

Figure 1

16 pages, 18300 KB  
Article
How to Make Reliable, Washable, and Wearable Textronic Devices
by Xuyuan Tao, Vladan Koncar, Tzu-Hao Huang, Chien-Lung Shen, Ya-Chi Ko and Gwo-Tsuen Jou
Sensors 2017, 17(4), 673; https://doi.org/10.3390/s17040673 - 24 Mar 2017
Cited by 102 | Viewed by 8678
Abstract
In this paper, the washability of wearable textronic (textile-electronic) devices has been studied. Two different approaches aiming at designing, producing, and testing robust washable and reliable smart textile systems are presented. The common point of the two approaches is the use of flexible [...] Read more.
In this paper, the washability of wearable textronic (textile-electronic) devices has been studied. Two different approaches aiming at designing, producing, and testing robust washable and reliable smart textile systems are presented. The common point of the two approaches is the use of flexible conductive PCB in order to interface the miniaturized rigid (traditional) electronic devices to conductive threads and tracks within the textile flexible fabric and to connect them to antenna, textile electrodes, sensors, actuators, etc. The first approach consists in the use of TPU films (thermoplastic polyurethane) that are deposited by the press under controlled temperature and pressure parameters in order to protect the conductive thread and electrical contacts. The washability of conductive threads and contact resistances between flexible PCB and conductive threads are tested. The second approach is focused on the protection of the whole system—composed of a rigid electronic device, flexible PCB, and textile substrate—by a barrier made of latex. Three types of prototypes were realized and washed. Their reliabilities are studied. Full article
(This article belongs to the Special Issue Flexible Electronics and Sensors)
Show Figures

Figure 1

6 pages, 789 KB  
Article
Laser Fabrication of Miniature Internal Thread in Glass Substrate
by Hiroyuki Degawa, Noriaki Urano and Shigeki Matsuo
Micromachines 2017, 8(2), 48; https://doi.org/10.3390/mi8020048 - 8 Feb 2017
Cited by 7 | Viewed by 6360
Abstract
Miniature internal threads (tapped holes) of S0.5 were fabricated in a glass substrate. Water-assisted laser drilling was applied for fabrication of the threads of S0.5 standard using a subnanosecond laser as a light source. The landscape of the inner surface of the threads [...] Read more.
Miniature internal threads (tapped holes) of S0.5 were fabricated in a glass substrate. Water-assisted laser drilling was applied for fabrication of the threads of S0.5 standard using a subnanosecond laser as a light source. The landscape of the inner surface of the threads was measured by a laser microscope, and showed reasonable agreement with the desired standard. As a proof of concept, a commercial external screw was fitted to the fabricated internal thread. Full article
(This article belongs to the Special Issue Ultrafast Laser Fabrication for Lab-on-a-Chip)
Show Figures

Figure 1

17 pages, 6960 KB  
Article
Microfluidic 3D Helix Mixers
by Georgette B. Salieb-Beugelaar, Daniel Gonçalves, Marc P. Wolf and Patrick Hunziker
Micromachines 2016, 7(10), 189; https://doi.org/10.3390/mi7100189 - 17 Oct 2016
Cited by 17 | Viewed by 8146
Abstract
Polymeric microfluidic systems are well suited for miniaturized devices with complex functionality, and rapid prototyping methods for 3D microfluidic structures are increasingly used. Mixing at the microscale and performing chemical reactions at the microscale are important applications of such systems and we therefore [...] Read more.
Polymeric microfluidic systems are well suited for miniaturized devices with complex functionality, and rapid prototyping methods for 3D microfluidic structures are increasingly used. Mixing at the microscale and performing chemical reactions at the microscale are important applications of such systems and we therefore explored feasibility, mixing characteristics and the ability to control a chemical reaction in helical 3D channels produced by the emerging thread template method. Mixing at the microscale is challenging because channel size reduction for improving solute diffusion comes at the price of a reduced Reynolds number that induces a strictly laminar flow regime and abolishes turbulence that would be desired for improved mixing. Microfluidic 3D helix mixers were rapidly prototyped in polydimethylsiloxane (PDMS) using low-surface energy polymeric threads, twisted to form 2-channel and 3-channel helices. Structure and flow characteristics were assessed experimentally by microscopy, hydraulic measurements and chromogenic reaction, and were modeled by computational fluid dynamics. We found that helical 3D microfluidic systems produced by thread templating allow rapid prototyping, can be used for mixing and for controlled chemical reaction with two or three reaction partners at the microscale. Compared to the conventional T-shaped microfluidic system used as a control device, enhanced mixing and faster chemical reaction was found to occur due to the combination of diffusive mixing in small channels and flow folding due to the 3D helix shape. Thus, microfluidic 3D helix mixers can be rapidly prototyped using the thread template method and are an attractive and competitive method for fluid mixing and chemical reactions at the microscale. Full article
(This article belongs to the Special Issue Polymeric Microsystems)
Show Figures

Figure 1

Back to TopTop