Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = cut cylindrical metal electrode

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
23 pages, 2905 KB  
Article
Fluxgate Magnetometers Based on New Physical Principles
by Ivan V. Bryakin, Igor V. Bochkarev, Vadim R. Khramshin, Vadim R. Gasiyarov and Ivan N. Erdakov
Sensors 2025, 25(13), 3893; https://doi.org/10.3390/s25133893 - 22 Jun 2025
Viewed by 3423
Abstract
This article considers a fluxgate magnetometer (FM) that operates based on a new physical principle. The authors analyze how the alternating electric charge potential of a cylindrical metal electrode impacts the structure of a cylindrical permanent magnet made of composite-conducting ferrite. They demonstrate [...] Read more.
This article considers a fluxgate magnetometer (FM) that operates based on a new physical principle. The authors analyze how the alternating electric charge potential of a cylindrical metal electrode impacts the structure of a cylindrical permanent magnet made of composite-conducting ferrite. They demonstrate that this impact and permanent magnet structure initiate the emergence of polarons with oscillating magnetism. This causes significant changes in the entropy of indirect exchange and the related sublattice magnetism fluctuations that ultimately result in the generation of circularly polarized spin waves at the spin wave resonance frequency that are channeled and evolve in dielectric ferrite waveguides of the FM. It is demonstrated that these moving spin waves have an electrodynamic impact on the measuring FM coils on the macro-level and perform parametric modulation of the magnetic permeability of the waveguide material. This results in the respective variations of the changeable magnetic field, which is also registered by the measuring FM coils. The authors considered a generalized flow of the physical processes in the FM to obtain a detailed representation of the operating functions of the FM. The presented experimental results for the proposed FM in the field meter mode confirm its operating parameters (±40 μT—measurement range, 0.5 nT—detection threshold). The usage of a cylindrical metal electrode as a source of exciting electrical change instead of a conventional multiturn excitation coil can significantly reduce temperature drift, simplify production technology, and reduce the unit weight and size. Full article
(This article belongs to the Section Physical Sensors)
Show Figures

Figure 1

10 pages, 3727 KB  
Article
Enhancement of the Localization Effect during Electrochemical Machining of Inconel 718 by Using an Alkaline Solution
by Dengyong Wang, Bin He and Wenjian Cao
Appl. Sci. 2019, 9(4), 690; https://doi.org/10.3390/app9040690 - 18 Feb 2019
Cited by 25 | Viewed by 4236
Abstract
Electrochemical machining (ECM) is a cost-effective method for the machining of difficult-to-cut Inconel 718 superalloy. However, the machining accuracy of ECM is still limited by the poor localization effect due to the existence of stray corrosion. In this paper, a mixed solution of [...] Read more.
Electrochemical machining (ECM) is a cost-effective method for the machining of difficult-to-cut Inconel 718 superalloy. However, the machining accuracy of ECM is still limited by the poor localization effect due to the existence of stray corrosion. In this paper, a mixed solution of neutral NaNO3 and alkaline NaOH is used to improve the localization effect during ECM of Inconel 718. The potentiodynamic polarization curves and current efficiencies for metal dissolution are measured, and the micro morphologies are examined. The results show that the use of an alkaline solution can promote the formation of a compact passive film on the surface of Inconel 718. ECM tests with cylindrical electrodes are specially designed to verify the effect of alkaline solution on the localization of anodic dissolution. The experimental results indicated that the stray corrosion of the non-machined surface of Inconel 718 alloy can be effectively eliminated by using a mixed solution of NaNO3 and NaOH. The surface roughness of the non-machined area can be noticeably improved. Full article
Show Figures

Figure 1