Article
A Simplified Model Validation for the Energy Assessment of Opaque Adaptive Façades with Variable Thermal Resistance
by Ismael Palacios Mackay, Laura Marín-Restrepo and Alexis Pérez-Fargallo
Energies 2025, 18(11), 2682; https://doi.org/10.3390/en18112682 - 22 May 2025
Cited by 1 | Viewed by 934
Abstract
Adaptive façades, also known as climate-adaptive building shells (CABSs), could make a significant contribution towards reducing the energy consumption of buildings and their environmental impacts. There is extensive research on glazed adaptive façades, mainly due to the available technology for glass materials. The [...] Read more.
Adaptive façades, also known as climate-adaptive building shells (CABSs), could make a significant contribution towards reducing the energy consumption of buildings and their environmental impacts. There is extensive research on glazed adaptive façades, mainly due to the available technology for glass materials. The technological development of opaque adaptive façades has focused on variable-thermal-resistance envelopes, and the simulation of this type of façade is a challenging task that has not been thoroughly studied. The aim of this study was to configure and validate a simplified office model that could be used for simulating an adaptive façade with variable thermal resistance via adaptive insulation thickness in its opaque part. Software-to-software model comparison based on the results of an EnergyPlus Building Energy Simulation Test 900 (BesTest 900)-validated model was used. Cooling and heating annual energy demand (kWh), peak cooling and heating (kW), and maximum, minimum, and average annual hourly zone temperature variables were compared for both the Adaptive and non-adaptive validated model. An Adaptive EnergyPlus model based on the BesTest 900 model, which uses the EnergyPlus SurfaceControl:MovableInsulation class list, was successfully validated and could be used for studying office buildings with a variable-thermal-resistance adaptive façade wall configuration, equivalent to a heavyweight mass wall construction with an External Insulation Finishing System (EIFS). An example of the Adaptive model in the Denver location is included in this paper. Annual savings of up to 26% in total energy demand (heating + cooling) was achieved and could reach up to 54% when electro-chromic (EC) glass commanded by a rule-based algorithm was added to the glazed part of the variable-thermal-resistance adaptive façade. Full article
(This article belongs to the Special Issue Advanced Building Materials for Energy Saving—2nd Edition)
Show Figures

Figure 1

19 pages, 3264 KB  
Article
Exploring the Effects of Climate-Adaptive Building Shells: An Applicative Time-Saving Algorithm on a Case Study in Bologna, Italy
by Jacopo Gaspari and Kristian Fabbri
Energies 2022, 15(21), 8168; https://doi.org/10.3390/en15218168 - 2 Nov 2022
Cited by 5 | Viewed by 3520
Abstract
Adaptive façades represent a viable and effective technological solution to reduce the building energy demand for cooling while achieving interesting aesthetic effects on the building envelope to screen solar radiation. During the last decade, many different design solutions, including those based on shape [...] Read more.
Adaptive façades represent a viable and effective technological solution to reduce the building energy demand for cooling while achieving interesting aesthetic effects on the building envelope to screen solar radiation. During the last decade, many different design solutions, including those based on shape memory alloys, have been experimented to obtain appropriate responses without being dependent on electro-mechanically actuated systems. Several recent and ongoing studies have been published in the scientific literature regarding the different actuator typologies, as well as the different properties of the materials used, which usually determine the adaptive solution characteristics after a series of complex and time-consuming simulations using specialised dynamic modelling software. Due to the time and resources required, this kind of evaluation is usually delivered during the last and more advanced design stage as a form of assessment of already-taken architectural and technological choices. The study reported in the paper aims to offer a quick, time-saving simplified algorithm to calculate the response of an adaptive façade, according to the ISO 13790 standards, to be adopted during the early design stage to evaluate the possible effects of design decisions. The study includes three main steps: (a) the conceptualisation of the adaptive solution considering the context conditions; (b) the definition of the calculation algorithm; (c) the application of the method to a test room in a case study building located in Bologna for supporting the discussion of the related outcomes. Full article
Show Figures

Figure 1

21 pages, 14624 KB  
Article
New Taxonomy of Climate Adaptive Building Shell Office Buildings: Focus on User–Façade Interaction Scenarios
by Nazgol Hafizi and Sadiye Mujdem Vural
Energies 2022, 15(14), 5268; https://doi.org/10.3390/en15145268 - 20 Jul 2022
Cited by 6 | Viewed by 2680
Abstract
As one of the most critical considerations in the contemporary era, sustainability heightens the need to find more suitable solutions for architectural designs. Climate adaptive building shells (CABS) are among the most promising alternatives for achieving sustainability goals by reducing energy consumption. Regardless [...] Read more.
As one of the most critical considerations in the contemporary era, sustainability heightens the need to find more suitable solutions for architectural designs. Climate adaptive building shells (CABS) are among the most promising alternatives for achieving sustainability goals by reducing energy consumption. Regardless of technological developments, this type of system has a reputation for increasing the distraction of occupants and consequently decreasing their satisfaction level. This research has been developed to focus on the occupant-centric study rather than technological advancements of the system. This study introduces the user–façade interaction scenarios and applies this classification on CABS office buildings. The purpose of this study is to introduce a new multi-domain taxonomy for CABS office buildings and update the database of this system by adding a new variable focusing on occupants. The study was designed on the foundation found with PRISMA methodology which highlights the lack of occupant-centric research on CABS. The research carried on as a qualitative method with an inductive approach which with the literature review introduced the user–façade interaction scenarios and the latest update of the CABS database. Accordingly, the office cases were categorized within different climatic zones, and later as a correlational study, each case was studied based on user–façade interaction scenarios. Analysis of case databases according to user–façade interaction types clears the lack of development in the majority of scenarios. Lastly, the study concluded by introducing a novel multi-domain taxonomy of CABS office buildings by considering user–façade interaction scenarios. The further value of this study is to be a foundation for future studies on CABS office buildings by considering the occupants as a primary element of the research. Full article
Show Figures

Figure 1

15 pages, 4190 KB  
Article
A Replicable Methodology to Evaluate Passive Façade Performance with SMA during the Architectural Design Process: A Case Study Application
by Kristian Fabbri and Jacopo Gaspari
Energies 2021, 14(19), 6231; https://doi.org/10.3390/en14196231 - 30 Sep 2021
Cited by 8 | Viewed by 3327
Abstract
Huge efforts have been made in recent decades to improve energy saving in the building sector, particularly focused on the role of façades. Among the explored viable solutions, climate-adaptive building shells [CABS] consider promising solutions to control solar radiation, both in terms of [...] Read more.
Huge efforts have been made in recent decades to improve energy saving in the building sector, particularly focused on the role of façades. Among the explored viable solutions, climate-adaptive building shells [CABS] consider promising solutions to control solar radiation, both in terms of illuminance and heating levels, but are still piloting these solutions due to their complex designs and necessary costs. The present study aims to provide a speedy but reliable methodology to evaluate the potential impacts of adopting active/passive CABS systems during the preliminary design stage. The proposed methodology allows the evaluation and comparison, when multiple options are considered, of the effects of each solution in terms of the energy needs, thermal comfort and lighting, while reducing the required effort and time for an extensive analysis of the overall building level. This is based on the use of a “virtual test room” where different conditions and configurations can be explored. A case study in the city of Bologna is included for demonstration purposes. The achieved results support the decisions made regarding energy behavior (over/under heating), indoor comfort, lighting and energy at an early design stage. Full article
Show Figures

Figure 1

12 pages, 1744 KB  
Article
Numerical Analysis of Building Envelope with Movable Phase Change Materials for Heating Applications
by Alvaro de Gracia
Appl. Sci. 2019, 9(18), 3688; https://doi.org/10.3390/app9183688 - 5 Sep 2019
Cited by 18 | Viewed by 3168
Abstract
Latent heat storage materials have been tested by several researchers for decades to be used as passive heating and cooling systems in buildings but their implementation into building components is still stacked as is facing specific technical limitations related to difficulties to be [...] Read more.
Latent heat storage materials have been tested by several researchers for decades to be used as passive heating and cooling systems in buildings but their implementation into building components is still stacked as is facing specific technical limitations related to difficulties to be charged both in heating and cooling periods. This paper presents a numerical analysis to evaluate the potential of a disruptive system, which is designed to solve the main drawbacks and to convert phase change materials (PCM) passive heating technology into a competitive solution for the building sector. The novel technology moves PCM layer with respect to the insulation layer inside the building component to maximize solar benefits in winter and be able to actively provide space heating. Design variables such as PCM melting point and control schemes were optimized. The results demonstrated that this technology is not only able to limit heat losses towards outdoors but it can provide space heating from stored solar energy when required. The promising numerical results endorse the possibility to build a future experimental prototype to quantify more in detail the benefits of this system. Full article