Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = candle smoke

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
31 pages, 5058 KB  
Article
Emission Characterization of Synthetic and Natural Candles in a Residential Environment
by Dalton Crunkelton, Marcel Ilie, Dorothy Seybold, Jhy-Charm Soo and Atin Adhikari
Atmosphere 2026, 17(5), 515; https://doi.org/10.3390/atmos17050515 - 18 May 2026
Viewed by 188
Abstract
The combustion of candles is known to emit various air pollutants, including particulate matter (PM) and volatile organic compounds (VOCs), into the air. This study characterizes emissions of these pollutants from natural and synthetic candles in a standard, sealed, unventilated residential environment. In [...] Read more.
The combustion of candles is known to emit various air pollutants, including particulate matter (PM) and volatile organic compounds (VOCs), into the air. This study characterizes emissions of these pollutants from natural and synthetic candles in a standard, sealed, unventilated residential environment. In addition, computational fluid dynamics (CFD) modeling was used to study the potential effects of inlet air velocity on a paraffin candle flame. A laminar diffusion flame model simulated the distributions of temperature, CO2, and H2O. A Testo DiSC mini air sampler was used for ultrafine particles and Lung-Deposited Surface Area (LDSA) data collection, and a CEM DT-9881 sampler was used for recording larger particle number concentrations, temperature, and relative humidity. VOC sorbent tubes were used for the collection of individual and total VOCs. Study findings showed that natural candles produced significantly (p < 0.05) higher LDSA ranges (mean 195.2 µm2/cm3) and ultrafine particle concentrations (mean 8.4 × 1011 No/m3), while paraffin wax synthetic candles exhibited higher 0.3–10 µm PM concentrations (mean 2.0 × 107 No/m3). CFD modeling showed that increasing air velocity produced a shorter, more compact flame and reduced CO2 and H2O mass fractions due to enhanced mixing and aerodynamic dilution, highlighting the strong interaction between airflow, temperature, and product formation in laminar paraffin flames. Full article
(This article belongs to the Section Air Quality and Health)
Show Figures

Figure 1

36 pages, 15146 KB  
Article
Laboratory Evaluation of ARMIE, a Portable SPS30-Based Low-Cost Sensor Node for PM2.5 Monitoring
by Asbjørn Kloppenborg, Louise B. Frederickson, Rasmus Ø. Nielsen, Clive E. Sabel, Tue Skallgaard, Jakob Löndahl, Jose G. C. Laurent and Torben Sigsgaard
Sensors 2026, 26(1), 280; https://doi.org/10.3390/s26010280 - 2 Jan 2026
Viewed by 771
Abstract
Background: Low-cost particulate matter sensors have enabled new opportunities for exposure monitoring but require evaluation before application in epidemiological studies. This study assessed the performance of the SPS30 sensor integrated into the ARMIE portable monitoring sensor-node under controlled laboratory conditions. Methods: Sensors were [...] Read more.
Background: Low-cost particulate matter sensors have enabled new opportunities for exposure monitoring but require evaluation before application in epidemiological studies. This study assessed the performance of the SPS30 sensor integrated into the ARMIE portable monitoring sensor-node under controlled laboratory conditions. Methods: Sensors were co-located with two comparison instruments—the optical DustTrak photometer and the combined Scanning Mobility Particle Sizer (SMPS) and Aerodynamic Particle Sizer (APS)—across multiple aerosol sources, including candle burning, cooking, cigarette smoke, and clean air, under both regular and high-humidity conditions. Calibration performance was evaluated using leave-one-sensor-out and leave-one-source-out approaches. Results: The ARMIE node demonstrated strong agreement with the DustTrak (r = 0.93–0.98) and maintained linear response characteristics across emission types. Calibration reduced mean errors and narrowed the limits of agreement. Agreement with the SMPS + APS was moderate (r = 0.74–0.94) and characterized by systematic underestimation at higher concentrations. Conclusions: Overall, the ARMIE node achieved high correlation with the DustTrak, demonstrating that low-cost optical sensors can reliably capture temporal variability in particle concentrations relative to mid-cost photometers. Full article
(This article belongs to the Section Environmental Sensing)
Show Figures

Figure 1

24 pages, 743 KB  
Systematic Review
Indoor Air Pollution and the Health of Vulnerable Groups: A Systematic Review Focused on Particulate Matter (PM), Volatile Organic Compounds (VOCs) and Their Effects on Children and People with Pre-Existing Lung Disease
by Tun Z. Maung, Jack E. Bishop, Eleanor Holt, Alice M. Turner and Christian Pfrang
Int. J. Environ. Res. Public Health 2022, 19(14), 8752; https://doi.org/10.3390/ijerph19148752 - 19 Jul 2022
Cited by 270 | Viewed by 26646
Abstract
Air pollution affects health, but much of the focus to this point has been on outdoor air. Higher indoor pollution is anticipated due to increasingly energy-efficient and less leaky buildings together with more indoor activities. Studies of indoor air pollution focusing on children [...] Read more.
Air pollution affects health, but much of the focus to this point has been on outdoor air. Higher indoor pollution is anticipated due to increasingly energy-efficient and less leaky buildings together with more indoor activities. Studies of indoor air pollution focusing on children and people with respiratory disease from the database Web of Science (1991–2021) were systemically reviewed according to the PRISMA guidelines, with 69 studies included in the final selection. Emissions from building materials affected indoor air quality, and ventilation also had an influence. The main indoor air pollutants are Volatile Organic Compounds (VOCs) and Particulate Matter (PM). PM sources included smoking, cooking, heating, candles, and insecticides, whereas sources of coarse particles were pets, housework and human movements. VOC sources included household products, cleaning agents, glue, personal care products, building materials and vehicle emissions. Formaldehyde levels were particularly high in new houses. Personal exposure related to both indoor and outdoor pollutant levels, highlighting home characteristics and air exchange rates as important factors. Temperature, humidity, educational level, air purifiers and time near sources were also related to personal exposure. There was an association between PM and Fractional exhaled Nitric Oxide (FeNO), lung function, oxygen saturation, childhood asthma and symptoms of chronic obstructive pulmonary disease (COPD) patients. High VOCs were associated with upper airways and asthma symptoms and cancer. Effective interventional studies for PM in the future might focus on human behavior together with air purifiers and increased ventilation, whereas VOC interventions might center more on building materials and household products, alongside purification and ventilation. Full article
Show Figures

Figure 1

24 pages, 2271 KB  
Review
Indoor Exposure to Selected Air Pollutants in the Home Environment: A Systematic Review
by Sotiris Vardoulakis, Evanthia Giagloglou, Susanne Steinle, Alice Davis, Anne Sleeuwenhoek, Karen S. Galea, Ken Dixon and Joanne O. Crawford
Int. J. Environ. Res. Public Health 2020, 17(23), 8972; https://doi.org/10.3390/ijerph17238972 - 2 Dec 2020
Cited by 459 | Viewed by 38126
Abstract
(1) Background: There is increasing awareness that the quality of the indoor environment affects our health and well-being. Indoor air quality (IAQ) in particular has an impact on multiple health outcomes, including respiratory and cardiovascular illness, allergic symptoms, cancers, and premature mortality. (2) [...] Read more.
(1) Background: There is increasing awareness that the quality of the indoor environment affects our health and well-being. Indoor air quality (IAQ) in particular has an impact on multiple health outcomes, including respiratory and cardiovascular illness, allergic symptoms, cancers, and premature mortality. (2) Methods: We carried out a global systematic literature review on indoor exposure to selected air pollutants associated with adverse health effects, and related household characteristics, seasonal influences and occupancy patterns. We screened records from six bibliographic databases: ABI/INFORM, Environment Abstracts, Pollution Abstracts, PubMed, ProQuest Biological and Health Professional, and Scopus. (3) Results: Information on indoor exposure levels and determinants, emission sources, and associated health effects was extracted from 141 studies from 29 countries. The most-studied pollutants were particulate matter (PM2.5 and PM10); nitrogen dioxide (NO2); volatile organic compounds (VOCs) including benzene, toluene, xylenes and formaldehyde; and polycyclic aromatic hydrocarbons (PAHs) including naphthalene. Identified indoor PM2.5 sources include smoking, cooking, heating, use of incense, candles, and insecticides, while cleaning, housework, presence of pets and movement of people were the main sources of coarse particles. Outdoor air is a major PM2.5 source in rooms with natural ventilation in roadside households. Major sources of NO2 indoors are unvented gas heaters and cookers. Predictors of indoor NO2 are ventilation, season, and outdoor NO2 levels. VOCs are emitted from a wide range of indoor and outdoor sources, including smoking, solvent use, renovations, and household products. Formaldehyde levels are higher in newer houses and in the presence of new furniture, while PAH levels are higher in smoking households. High indoor particulate matter, NO2 and VOC levels were typically associated with respiratory symptoms, particularly asthma symptoms in children. (4) Conclusions: Household characteristics and occupant activities play a large role in indoor exposure, particularly cigarette smoking for PM2.5, gas appliances for NO2, and household products for VOCs and PAHs. Home location near high-traffic-density roads, redecoration, and small house size contribute to high indoor air pollution. In most studies, air exchange rates are negatively associated with indoor air pollution. These findings can inform interventions aiming to improve IAQ in residential properties in a variety of settings. Full article
(This article belongs to the Special Issue Designing Healthy Indoor Air Quality)
Show Figures

Figure 1

18 pages, 1691 KB  
Article
A Case Study Describing a Community-Engaged Approach for Evaluating Polycyclic Aromatic Hydrocarbon Exposure in a Native American Community
by Diana Rohlman, Jamie Donatuto, Myk Heidt, Michael Barton, Larry Campbell, Kim A. Anderson and Molly L. Kile
Int. J. Environ. Res. Public Health 2019, 16(3), 327; https://doi.org/10.3390/ijerph16030327 - 24 Jan 2019
Cited by 39 | Viewed by 7203
Abstract
In 2015, the Swinomish Indian Tribal Community (SITC) was impacted by an air toxic release from one of two nearby oil refineries. This experience motivated SITC members to learn more about their exposure to air toxics. On the invitation of SITC, this community-based [...] Read more.
In 2015, the Swinomish Indian Tribal Community (SITC) was impacted by an air toxic release from one of two nearby oil refineries. This experience motivated SITC members to learn more about their exposure to air toxics. On the invitation of SITC, this community-based study measured personal exposure to polycyclic aromatic hydrocarbons (PAHs) and conducted interviews with the volunteers to evaluate perceptions of the data and experience of participating. Non-smoking SITC members were recruited in March 2016 (N = 10) and January 2017 (N = 22) with seven volunteers participating both times. Volunteers wore a wristband passive sampler for 7 days and completed daily activity diaries. Wristbands were analyzed for 62 PAHs using gas chromatography mass spectrometry. Wilcoxon exact tests determined if the sum total PAHs (ΣPAH) differed by activity, proximity to the refineries, and time. Aggregated results were shared during community meetings, and volunteers received individual reports. Volunteers (N = 9) participated in individual interviews. All volunteers were exposed to different amounts and types of PAHs. Burning candles or using a wood stove and/or propane heating were associated with higher ΣPAH exposures. While ΣPAH was similar in both sampling periods, the composition of PAHs differed. More priority listed PAHs were detected in January (N = 17) versus March (N = 10). Among volunteers who participated in both sampling events, exposure to four PAHs significantly differed between seasons. Overall, volunteers reported that the study made them more aware of air pollution sources in their community. They also commented that the chemical nomenclature was difficult to understand, but appreciated the individual reports that allowed them to visually compare their data to the distribution of data collected in their community. For volunteers with lower exposures, these comparisons gave them relief. However, volunteers with higher exposures reported concern and several changed their behaviors to reduce their exposure to known PAH sources. This study provided an opportunity for SITC members to learn about their personal exposure to a class of air toxics within the context of their community. While the limitations of the study hindered the ability to identify sources of air toxics in the community, this activity appeared to raise awareness about ambient and indoor air pollution among the volunteers. Full article
(This article belongs to the Section Environmental Health)
Show Figures

Figure 1

Back to TopTop