Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = biotinylated hapten coating

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 3025 KB  
Article
Influence of Endogenous Factors of Food Matrices on Avidin—Biotin Immunoassays for the Detection of Bacitracin and Colistin in Food
by Maksim A. Burkin, Inna A. Galvidis and Sergei A. Eremin
Foods 2022, 11(2), 219; https://doi.org/10.3390/foods11020219 - 13 Jan 2022
Cited by 3 | Viewed by 2916
Abstract
(Strept)avidin–biotin technology is frequently used in immunoassay systems to improve their analytical properties. It is known from clinical practice that many (strept)avidin–biotin-based tests provide false results when analyzing patient samples with a high content of endogenous biotin. No specific investigation has been carried [...] Read more.
(Strept)avidin–biotin technology is frequently used in immunoassay systems to improve their analytical properties. It is known from clinical practice that many (strept)avidin–biotin-based tests provide false results when analyzing patient samples with a high content of endogenous biotin. No specific investigation has been carried out regarding possible interferences from avidin (AVI) and biotin (B7) contained in food matrices in (strept)avidin–biotin-based immunoanalytical systems for food safety. Two kinds of competitive ELISAs for bacitracin (BT) and colistin (COL) determination in food matrices were developed based on conventional hapten–protein coating conjugates and biotinylated BT and COL bound to immobilized streptavidin (SAV). Coating SAV–B7–BT and SAV–B7–COL complexes-based ELISAs provided 2- and 15-times better sensitivity in BT and COL determination, corresponding to 0.6 and 0.3 ng/mL, respectively. Simultaneously with the determination of the main analytes, these kinds of tests were used as competitive assays for the assessment of AVI or B7 content up to 10 and 1 ng/mL, respectively, in food matrices (egg, infant milk formulas enriched with B7, chicken and beef liver). Matrix-free experiments with AVI/B7-enriched solutions showed distortion of the standard curves, indicating that these ingredients interfere with the adequate quantification of analytes. Summarizing the experience of the present study, it is recommended to avoid immunoassays based on avidin–biotin interactions when analyzing biosamples containing these endogenous factors or enriched with B7. Full article
(This article belongs to the Special Issue Application of Antibody and Immunoassay for Food Safety)
Show Figures

Figure 1

Back to TopTop