Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = VividTrac®

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 780 KiB  
Article
Comparison of Macintosh Laryngoscope, King Vision®, VividTrac®, AirAngel Blade®, and a Custom-Made 3D-Printed Video Laryngoscope for Difficult and Normal Airways in Mannequins by Novices—A Non-Inferiority Trial
by Viktor Bacher, Márton Németh, Szilárd Rendeki, Balázs Tornai, Martin Rozanovic, Andrea Pankaczi, János Oláh, József Farkas, Melánia Chikhi, Ádám Schlégl, Péter Maróti and Bálint Nagy
J. Clin. Med. 2024, 13(11), 3213; https://doi.org/10.3390/jcm13113213 - 30 May 2024
Cited by 1 | Viewed by 1797
Abstract
Background: Endotracheal intubation (ETI) is a cornerstone of airway management. The gold standard device for ETI is still the direct laryngoscope (DL). However, video laryngoscopes (VLs) are now also widely available and have several proven advantages. The VL technique has been included in [...] Read more.
Background: Endotracheal intubation (ETI) is a cornerstone of airway management. The gold standard device for ETI is still the direct laryngoscope (DL). However, video laryngoscopes (VLs) are now also widely available and have several proven advantages. The VL technique has been included in the major airway management guidelines. During the COVID-19 pandemic, supply chain disruption has raised demand for 3D-printed medical equipment, including 3D-printed VLs. However, studies on performance are only sparsely available; thus, we aimed to compare 3D-printed VLs to the DL and other VLs made with conventional manufacturing technology. Methods: Forty-eight medical students were recruited to serve as novice users. Following brief, standardized training, students executed ETI with the DL, the King Vision® (KV), the VividTrac® (VT), the AirAngel Blade® (AAB), and a custom-made 3D-printed VL (3DVL) on the Laerdal® airway management trainer in normal and difficult airway scenarios. We evaluated the time to and proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma, and user satisfaction. Results: The KV and VT are proved to be superior (p < 0.05) to the DL in both scenarios. The 3DVL’s performance was similar (p > 0.05) or significantly better than that of the DL and mainly non-inferior (p > 0.05) compared to the KV and VT in both scenarios. Regardless of the scenario, the AAB proved to be inferior (p < 0.05) even to the DL in the majority of the variables. The differences between the devices were more pronounced in the difficult airway scenario. The user satisfaction scores were in concordance with the aforementioned performance of the scopes. Conclusions: Based upon our results, we cannot recommend the AAB over the DL, KV, or VT. However, as the 3DVL showed, 3D printing indeed can provide useful or even superior VLs, but prior to clinical use, meticulous evaluation might be recommended. Full article
(This article belongs to the Section Intensive Care)
Show Figures

Figure 1