- Article
This paper analyses the applicability of radar charts for evaluating sewage sludge dewatering efficiency, based on data for anaerobically digested sludge from a large municipal wastewater treatment plant. Four cationic polyelectrolytes, used alone and with the inorganic coagulant PIX C28 at 0–16 kg/t DS (32 variants), were compared in technological and economic terms. Eight normalization methods were assessed on the basis of the radar chart area variability across 12 geometrically distinct axis arrangements, complemented by the TOPSIS method. Min-Max and percentile normalizations proved most suitable (median coefficient of variation of the area: 0.0042 and 0.0118), while maximum-based normalization showed the distance from the best variant. PIX-assisted systems achieved the highest technological effect (mean TOPSIS score 0.938 vs. 0.660 for polyelectrolytes alone; maximum 0.995), allowing a fourfold reduction in polyelectrolyte dose. However, PIX C28 (€363.37/t DS) accounted for 78–95% of the conditioning cost, lowering techno-economic efficiency by about an order of magnitude. The most favourable effect-to-cost ratio was obtained for Zetag 8190 and Super Floc C446 used alone at 8 kg/t DS, whereas at 4 kg/t DS conditioning without the coagulant worsened the multi-criteria assessment despite reduced capillary suction time. The TOPSIS and radar chart assessments were strongly correlated (r = 0.967). These results confirm the need for multi-criteria evaluation, for which radar charts with an appropriately selected normalization method are a useful tool.
11 November 2026



![P3Oβ and PPVI exhibit dose-dependent cytotoxicity on THP-1 monocytes and OSCC cells. (a,b) The molecular structures of pennogenin 3-O-β-chacotrioside (P3Oβ, (a)) and polyphyllin VI (PPVI, (b)) from Paris polyphylla. (c–f) Cell survival was determined by CCK-8 assay and IC50 values of THP-1 and CaL27 cells were determined for the cytotoxicity of P3Oβ and PPVI. n = 3 biological replicates. Error bars represent the mean ± SEM. IC50 values were calculated using non-linear regression analysis in GraphPad Prism v [8.4.2] with a sigmoidal dose–response curve fit. Statistical significance was determined using one-way ANOVA, followed by a two-side Dunnett’s test. IC50, half-maximal inhibitory concentration.](https://mdpi-res.com/molecules/molecules-31-04067/article_deploy/html/images/molecules-31-04067-g001-550.jpg)


![Reduction of branched polyethylenimine-derived carbamates to CO catalyzed by [SiCu2IIGaIII(H2O)3W9O37]9−. W: dark grey; Cu: blue; Ga: turquoise; O: red. For clarity the branched polyethylenimine is presented as a linear polymer.](https://mdpi-res.com/molecules/molecules-31-03276/article_deploy/html/images/molecules-31-03276-g001-550.jpg)



