Supplementary Materials - buildings-4660328 (final, proofread)
Veseli et al., "An Integrated, Experimentally Validated Micro-to-Macro Nonlinear Modeling Method for AAC Masonry-Infilled
RC Frame Buildings with Seismic Vulnerability Reduction Strategy"

S1_OpenSees_scripts (Python 3, openseespy >= 3.5, numpy)
  aacf.py        five-storey AACF model, base-fixed and base-isolated (original and revised versions), modal and time-history analysis
  single.py      single-storey AACF model of the tested frame: pushover and cyclic analyses (Table 15, Figure 15)
  study.py       all five-storey analyses of Sections 5.8-5.13 (model refinements, sensitivity, isolation, psi sweep, seven records)
                 usage: python study.py steps|iso|psi|art [n_processes]
  mphi.py        fibre-section moment-curvature analysis of the prototype column (axial-load factors, Section 4.4)
  axial_factors.json  axial-load factors of the column links (storeys 1-5)
  artificial.py  generation of the seven spectrum-compatible accelerograms (Section 3.4)
  figs.py        figures 15, 25-28
  figB1.py       Figure A1 in Appendix B (comparison with the cyclic test M2-A; single.path with the test displacement history)
S2_accelerograms
  Ulcinj_Albatros_022g_dt001.txt   record as used (nominal PGA 0.22 g = largest positive value; dt = 0.01 s; in g)
  EC8_artificial_7records_PGA1g_dt001.txt, EC8_artificial_spectra.txt
S3_results
  res_steps.json, res_iso.json, res_psi.json, res_art.json, res_single.json, res_fig25.json, res_m2a.json (cyclic test M2-A comparison) - numerical results
  Table15_envelopes_experiment_micromodel.csv - digitized envelopes used in Table 15
Units: kN, m (scripts); mm and % in the tables of the paper.