Skip to Content

Electricity, Volume 2, Issue 2

2021 June - 7 articles

Cover Story: The global development of high-voltage direct-current (HVDC) systems is unquestionably important. Though widely used, the modular multilevel converter with half-bridge cells is sensitive to DC pole-to-pole faults, and the time response of the protections is critical. Reliability and availability are paramount: circuit breakers must minimize the effects of any fault on the converter, while ensuring rapid restart. This paper focuses on the modelling aspects to analyse the behaviour of HVDC stations during DC pole to-pole faults, using either AC or DC circuit breakers, with different parameters. The proposed model can represent the main issues met by the converter cells during DC faults, such as semiconductor overcurrents and overvoltages, allowing for a proper design of the cells. View this paper.
  • Issues are regarded as officially published after their release is announced to the table of contents alert mailing list .
  • You may sign up for email alerts to receive table of contents of newly released issues.
  • PDF is the official format for papers published in both, html and pdf forms. To view the papers in pdf format, click on the "PDF Full-text" link, and use the free Adobe Reader to open them.

Articles (7)

  • Article
  • Open Access
14 Citations
5,185 Views
20 Pages

This paper presents an effective solution to overcome the problem caused by intermittent energy sources that are connected to a balanced/unbalanced distribution system using a superconducting magnetic energy storage (SMES) system by mitigating the vo...

  • Article
  • Open Access
46 Citations
10,498 Views
18 Pages

Nowadays, response to electricity consumption growth is mainly supported by efficiency; therefore, this is the new main goal in the development of electric distribution networks, which must fully comply with the system’s constraints. In recent decade...

  • Review
  • Open Access
8 Citations
8,680 Views
19 Pages

The introduction of series capacitors in transmission lines causes problems in terms of reliability and the security of distance protection relays. As distance protection is widely used in the transmission network, the challenge of applying it to ser...

  • Communication
  • Open Access
5 Citations
4,269 Views
10 Pages

Electromagnetic fields and the heat of a metal oxide varistor (MOV), in which a lightning impulse current flows, are calculated using the finite-difference time-domain (FDTD) method. The MOV is represented with small rectangular parallelepiped cells,...

  • Article
  • Open Access
16 Citations
10,716 Views
15 Pages

20 April 2021

The operation and the development of power system networks introduce new types of stability problems. The effect of the power generation and consumption on the frequency of the power system can be described as a demand/generation imbalance resulting...

  • Article
  • Open Access
3 Citations
5,140 Views
19 Pages

Simulation Model to Analyze the Consequences of DC Faults in MMC-Based HVDC Stations

  • Davin Guedon,
  • Philippe Ladoux,
  • Sébastien Sanchez and
  • Sébastien Cornet

12 April 2021

The global development of high-voltage direct-current (HVDC) systems in fields such as renewable energy sources, interconnection of asynchronous grids or power transmission over great distances, is unquestionably important. Though widely used, the mo...

  • Article
  • Open Access
3 Citations
3,183 Views
14 Pages

Due to the predicted rise of Unmanned Aircraft Systems (UAS) in commercial, civil, and military operations, there is a desire to make UASs more energy efficient so they can proliferate with ease of deployment and maximal life per charge. To address c...

XFacebookLinkedIn