Abstract
Background/Objectives: Recently, the European Association of Urology (EAU) guidelines presented the EAU guidelines bot to assist urologists in the reading of the guidelines; however, to date, no external validation is available. The aim of our study is to assess the accuracy, completeness, and clarity of the guidelines bot in reading renal transplantation guidelines and clinical cases. Methods: A total of 103 questions derived from the recommendations included in the EAU guidelines on renal transplantation, together with 10 distinct clinical scenarios, were created. Each question and clinical case was submitted to the EAU guidelines bot, and the corresponding responses were independently evaluated by two expert urologists in terms of accuracy, completeness, and clarity. Each domain was scored using a 5-point Likert scale. In cases of disagreement between the two reviewers, a third urologist was consulted. Accuracy, completeness, and clarity were analyzed for the clinical cases and per chapter and grade of recommendation for the questions. Results: Overall, 103 questions were generated. Regarding accuracy, 101/103 responses (98%) were classified as accurate, corresponding to scores of 4–5, whereas 2/103 responses (2%) showed fair accuracy, corresponding to a score of 3. No responses were considered inaccurate, defined as a score of 1–2. In terms of completeness, 101/103 responses (98%) were judged to be complete, with scores of 4–5, while 2/103 responses (2%) were rated as fairly complete, with a score of 3. No responses were classified as incomplete. With regard to clarity, 102/103 responses (99%) were considered clear, corresponding to scores of 4–5, whereas 1/103 response (1%) was rated as fairly clear, with a score of 3. No responses were deemed unclear. No significant differences were observed when comparing responses related to strong versus weak recommendations. For the clinical scenarios, 8/10 responses (80%) were rated as accurate, with scores of 4–5, while 2/10 responses (20%) showed fair accuracy, with a score of 3. Regarding completeness, all 10 responses (100%) were classified as fairly complete, corresponding to a score of 3. Finally, in terms of clarity, 8/10 responses (80%) were judged to be clear, with scores of 4–5, whereas 2/10 responses (20%) were rated as fairly clear, with a score of 3. Conclusions: The EAU guidelines bot represents an accurate tool for renal transplantation. Besides some occasional inaccuracies the bot is an excellent tool for urologists, especially to clarify doubt about the EAU guidelines. At the same time, it can give good support when facing a clinical case.
1. Introduction
Kidney grafts are the most commonly transplanted solid organ.
Renal transplantation is the best treatment option for patients with end-stage renal disease owing to improved survival and quality of life compared with dialysis.
Furthermore, kidney transplantation can also be a solution for many congenital urological disease originating prenatally and present at birth, as urethral valves, cloacal anomalies, and reflux nephropathy. These anomalies can lead to chronic kidney disease (CKD) or end-stage kidney disease (ESKD) in children, necessitating renal replacement therapy or transplantation [1].
However, many issues can involve the transplanted kidney, such as stones, cancers, and graft-versus-host disease.
All these reasons justify the need for a proper assessment, diagnosis and indication from the medical doctor and for good communication with the patient, also using novel tools, such as artificial intelligence (AI), that have shown promising results in this direction.
AI has rapidly emerged as a transformative force in modern healthcare, reshaping the ways clinicians diagnose, treat, and interact with patients. Among the various AI-driven tools, conversational agents—commonly known as chatbots—have gained increasing attention for their potential to enhance clinical workflows, expand access to health information, and support patient self-management, simulating human-like dialog and deliver tailored recommendations.
Early evidence suggests that, when properly designed and validated, they can reduce healthcare burdens, improve efficiency, and contribute to more personalized care. ChatGPT 5.5 version demonstrated a potential utility in educating patients and helping in the decision-making process [2].
Recently the European Association of Urology (EAU) guidelines presented the EAU guidelines bot to assist urologists in the reading of the guidelines; however, to date, no external validation is available. The aim of our study is to assess the accuracy, completeness, and clarity of the guidelines bot in reading renal transplantation guidelines.
2. Materials and Methods
Recommendations were extracted from the renal transplantation section of the 2025 EAU guidelines and subsequently converted into questions.
Questions were drafted by the first expert urologist (R.L) by directly rephrasing each guideline recommendation into a closed clinical question, preserving the clinical content and terminology of the original recommendation. All questions were subsequently reviewed independently by the second expert urologist (C.D.N) to verify that the phrasing was faithful to the corresponding recommendation and did not introduce ambiguity or leading language; discrepancies were resolved by consensus discussion. As regards the clinical cases, all of them were designed by the first expert urologist and then reviewed independently by the second expert urologist.
Also on this occasion, discrepancies were resolved by consensus discussion.
A total of 103 questions were systematically submitted to the EAU guidelines bot. The chatbot assessed in this study is an artificial intelligence tool developed by the EAU Guidelines Office to generate evidence-based responses based on the content of the EAU guidelines.
In addition, 10 clinical scenarios related to renal transplantation were submitted to the EAU guidelines bot in order to explore its potential applicability and performance in real-life clinical practice.
Clinical scenarios were deliberately constructed to reflect real-world complexity beyond straightforward eligibility questions, incorporating features such as high immunological sensitization, disease with known recurrence risk after transplantation (e.g., focal segmental glomerulosclerosis [FSGS]), and relevant comorbidities requiring multidisciplinary consideration (e.g., chronic hepatitis C virus [HCV] infection with liver fibrosis, active autoimmune disease). This design choice aimed to test the bot’s ability to integrate multiple guideline domains rather than to retrieve a single recommendation.
Each response was evaluated according to three domains: accuracy, completeness, and clarity. Two board-certified urologists independently assessed every answer using a 5-point Likert scale for each domain, where 5 indicated excellent, 4 good, 3 fair, 2 poor, and 1 very poor (Table 1 and Table S1). When discrepancies occurred between the two evaluators, a third senior urologist reviewed the assessment. In these cases, the final score was calculated as the median of the scores assigned by all three reviewers (Table S2).
Table 1.
Scoring anchors (5-point Likert scale) applied by reviewers for each domain.
Ethics committee approval was not required, as no patient data were recorded or used in this study. Accuracy was defined as the degree to which the response correctly reflected the established guideline recommendations. Completeness assessed whether the answer covered all relevant aspects of the question. Clarity evaluated how understandable, coherent, and well structured the response was for the target audience.
To minimize overlap between domains, the two expert urologists applied the following operational rule: accuracy was assessed exclusively on whether any statement in the response contradicted or misrepresented the guideline recommendation, irrespective of how much information was provided; completeness was assessed against a pre-specified checklist of clinically relevant elements extracted from each guideline recommendation prior to review, regardless of whether the elements present were correctly stated; and clarity was assessed independently of content correctness or completeness, focusing solely on structure, logical flow, and appropriateness of language for the target reader (Table 2).
Table 2.
Operational definitions and decision rules used to distinguish accuracy, completeness, and clarity.
The checklist, used for the completeness domain, was defined before the bot’s answers were read by the two expert urologists.
The performance of the bot was summarized by analyzing the distribution of scores for each domain across all questions. High performance was defined as a score of 4 or 5 for each attribute. For every domain, the number and percentage of responses classified as high, fair, or poor were calculated.
Questions were also categorized according to the strength of the corresponding guideline recommendation, distinguishing between strong and weak recommendations, in order to determine whether the bot’s performance differed between these groups. For each domain, the proportion of high-scoring answers in the strong-recommendation group was compared with that in the weak-recommendation group. Given the small sample size of the weak-recommendation group (n = 26), Fisher’s exact test was used instead of the chi-square test to compare the proportion of high-scoring responses between strong and weak recommendations.
As an example of the evaluation process, Table 3 reports one accurate and one inaccurate response, each compared with the corresponding guideline recommendation.
Table 3.
An example of an accurate, clear and complete answer and a partial inaccurate and unclear answer.
All analyses were descriptive, and data were organized using Microsoft Excel. The complete list of questions is provided in the Supplementary File S1 “Validation Chatbox Renal Transplanation”.
The study was conducted in accordance with the Declaration of Helsinki, and approved by the Institutional Review Board of Ospedale Sant’Andrea Rome Italy (14085) on 14 October 2021.
3. Results
Overall, a total of 103 questions were generated. With regard to accuracy, 101/103 answers (98%) were classified as accurate, corresponding to scores of 4–5, whereas 2/103 answers (2%) achieved a fair accuracy rating, corresponding to a score of 3. None of the answers received an accuracy score of 1 or 2.
Concerning completeness, 101/103 answers (98%) were judged to be complete, with scores of 4–5, while 2/103 answers (2%) were considered fairly complete, with a score of 3. No answer was assigned a completeness score of 1 or 2.
Regarding clarity, 102/103 answers (99%) were evaluated as clear, with scores of 4–5, whereas 1/103 answer (1%) was rated as fairly clear, with a score of 3. No answer received a clarity score of 1 or 2.
In addition, 77 questions were related to strong recommendations, while 26 questions addressed weak recommendations.
Fisher’s exact test showed no significant difference between strong and weak recommendations for accuracy (99% vs. 96%; difference 2.5 percentage points, 95% confidence interval [CI] −5.3 to 10.4; p = 0.443), completeness (97% vs. 100%; difference −2.6 pp, 95% CI −6.2 to 1.0; p = 1.000), or clarity (99% vs. 100.0%; difference −1.3 pp, 95% CI −3.8 to 1.2; p = 1.000). The wide confidence intervals, particularly for accuracy, reflect the limited sample size in the weak-recommendation group and indicate that a clinically meaningful difference cannot be excluded; these findings should be interpreted as descriptive rather than as evidence of true equivalence. These findings are reported in Table 4.
Table 4.
Overall and stratified performance of the European Association of Urology (EAU) guidelines bot in answering renal transplantation guideline questions. The top section summarizes the distribution of accuracy, completeness, and clarity ratings across all 103 bot-generated responses, categorized as excellent/good (scores 4–5), fair (score 3), or poor (scores 1–2). The bottom section compares the proportion of high-quality responses (score 4–5) between questions based on strong versus weak guideline recommendations, with corresponding p-values.
Subsequently, 10 clinical scenarios were submitted to the EAU guidelines bot (Supplementary File S2 “Clinical cases”). In terms of accuracy, 8/10 responses (80%) were considered accurate, with scores of 4–5, whereas 2/10 responses (20%) were rated as having fair accuracy, with a score of 3. For completeness, all 10 responses (100%) were classified as fairly complete, corresponding to a score of 3. Finally, regarding clarity, 8/10 responses (80%) were judged to be clear, with scores of 4–5, while 2/10 responses (20%) were rated as fairly clear, with a score of 3.
4. Discussion
AI have started to gain widespread use in kidney transplantation as in radiological evaluation of the allograft, pathological evaluation including molecular evaluation of the tissue, prediction of graft survival, optimizing the dose of immunosuppression, diagnosis of rejection, and prediction of early graft function [3,4,5].
Our study represents the first external evaluation of the EAU guidelines bot in the domain of renal transplantation, providing important insights into its performance, reliability, and potential role in clinical practice.
About this last point, the EAU guidelines bot could be integrated as a rapid point-of-care reference during outpatient consultations or multidisciplinary meetings, allowing clinicians to quickly verify guideline-based recommendations without manually searching the full guideline document, or as a training aid for residents unfamiliar with the full text of the guidelines. However, reliance on the tool carries risks: clinicians may be tempted to accept its output without independently verifying it against the primary guideline source, especially under time pressure; the tool should therefore be positioned as a decision-support aid rather than a substitute for clinical judgment or for consultation of the original guideline document, particularly in complex or atypical cases such as those explored in our clinical scenarios, where completeness was lower.
Prior research shows that general ChatGPT often gives incomplete or imprecise information without customization.
Badi Rawashdeh et al. have evaluated the application and accuracy of ChatGPT in the field of kidney transplantation, demonstrating that ChatGPT is able to define terms precisely and provide general information about different topics related to kidney transplants. However, it was unable to provide references and its responses contained inaccurate data, showing a lack of in-depth understanding of the subject [6].
Even considering other medical fields, ChaGPT did not show very accurate and appropriate answers. According to Lombardo et al., for example, ChatGPT’s responses to prostate cancer questions based on guidelines had only 26% accuracy, compared to about 90% with the customized EAU guidelines bot [6].
Anyway, this comparison is not entirely equivalent: ChatGPT is a general-purpose large language model without guideline-specific customization, whereas the EAU guidelines bot was purpose-built and fine-tuned on the guideline content itself. The marked performance difference (26% vs. ~90% accuracy) therefore likely reflects, at least in part, the benefit of domain-specific customization and retrieval grounding rather than a direct measure of one model’s general superiority over the other. Nonetheless, the comparison illustrates the potential value of guideline-specific tuning over general-purpose chatbot use for clinical guideline consultation.
The strong results of the EAU chatbot across all metrics highlight several meaningful implications. First, the very high accuracy rate (98%) indicates that the bot is generally able to interpret clinical questions correctly and provide content aligned with the official EAU recommendations. Second, the identical performance in completeness (98%) indicates that the majority of the chatbot’s answers not only include the correct recommendation but also provide sufficiently detailed context to assist clinicians in understanding the rationale or scope of the guideline. Third, clarity ratings (99%) show that the bot can communicate information in a straightforward and user-friendly manner, a critical feature for both clinicians under time pressure and potential future applications involving patient-focused communication.
Importantly, the chatbot’s performance did not differ between strong and weak recommendations, demonstrating that the system can handle both high- and lower-certainty evidence with similar reliability. This is reassuring, considering that weak recommendations often require more nuanced interpretation and may be more challenging for automated systems to summarize accurately.
Despite these positive findings, the study also identified a small number of inaccurate, incomplete, or unclear responses. Although such cases were rare, they highlight areas for continued model refinement. These occasional errors underscore the risk of over-reliance on automated tools and the persistent need for clinician oversight.
However, some limitations must be acknowledged. This evaluation focused exclusively on the renal transplantation section; performance may differ in other urological domains. Furthermore, most of the questions were derived directly from recommendations and only 10 questions from real-world clinical scenarios, which may not fully capture the complexity, ambiguity, and nuance of actual clinical queries. Qualitative review of the ten clinical-scenario responses revealed a consistent pattern underlying the uniform completeness score of 3. In every case, the bot correctly identified whether transplantation was indicated and outlined relevant evaluation domains in general terms (e.g., cardiovascular risk assessment, immunosuppressive management), which sustained high accuracy ratings. However, responses systematically lacked recommendation-strength attribution and case-specific operational detail. For instance, in the case of a highly sensitized patient (panel reactive antibody [PRA] 95%, donor-specific antibodies), the response referenced desensitization strategies and paired-exchange programs only in generic terms, without specifying guideline-based protocols. Similarly, in a patient with concomitant HCV infection and stage F2–F3 liver fibrosis, the response did not specify the recommended timing of antiviral therapy relative to transplantation or the criteria for combined liver–kidney transplantation. Recurrence risk was acknowledged in scenarios involving FSGS but was not accompanied by monitoring or prevention strategies. This suggests that the bot’s limitations lie not in identifying the core recommendation, but in synthesizing and operationalizing the multiple, case-specific guideline elements required for comprehensive clinical decision support—a competency distinct from, and more demanding than, single-recommendation retrieval.
Because our evaluation scored responses against explicit guideline recommendations, it is well suited to detect factual contradictions, but it does not specifically capture instances where the bot may present plausible-sounding but unverifiable claims, particularly for questions touching on areas where the guidelines are ambiguous, silent, or based on low-quality evidence.
It is likely that the deliberate complexity of the clinical scenarios contributed to the uniformly fair completeness scores, as these cases required the bot to integrate and prioritize multiple guideline-derived considerations rather than retrieve a single recommendation. This was an intentional design choice to stress-test the bot under realistic, non-trivial clinical conditions, rather than a limitation of the evaluation; however, it does mean that the completeness results for clinical scenarios should not be interpreted as representative of the bot’s performance on more straightforward clinical questions.
Additionally, the study did not evaluate the bot’s behavior in cases where guidelines are ambiguous, contradictory, or rapidly evolving—situations where AI models may be more prone to error.
Given that no responses were assigned scores of 1–2 in our dataset, the risk of incorrect or unsupported information in this specific context appears low; however, this should not be extrapolated to guideline areas outside renal transplantation or to genuinely novel clinical questions not directly derivable from the guideline text. Future work should specifically stress-test the bot with questions deliberately designed to probe boundary cases where guideline evidence is weak or absent.
A limitation of this study is that the initial level of agreement between the two primary reviewers was not formally quantified (e.g., via Cohen’s kappa), as third-reviewer adjudication scores were not retained separately from the original independent assessments. Future validation studies should report inter-rater reliability metrics to better characterize the reproducibility of the scoring system.
5. Conclusions
Our study demonstrates that the EAU guidelines bot is a highly reliable and clear tool that can support urologists in efficiently navigating guideline content and facing clinical cases. While continued monitoring and updates are essential to minimize occasional errors, the chatbot shows strong potential to enhance clinical workflow, improve access to evidence-based information, and complement traditional guideline consultation. Concretely, the bot may be most useful for quickly confirming the recommended strength and content of a specific guideline statement (e.g., before a clinic visit or tumor board), and less reliable as a stand-alone tool for synthesizing multi-step management plans in complex cases, where our data suggest that completeness is reduced.
Future research should explore its performance across other guideline sections, its integration into clinical decision-making workflows, and potential applications in patient education.
Supplementary Materials
The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/siuj7050074/s1, Table S1: Scoring anchors (5-point Likert scale) applied by reviewers for each domain; Table S2. Decision algorithm applied by reviewers; Supplementary File S1: Validation Chatbox Renal Transplantation; Supplementary File S2: Clinical cases.
Author Contributions
Conceptualization, P.S., R.L., M.B.S., E.R., M.R. (Matteo Romagnoli), S.D.C., E.C., D.A., M.R. (Mauro Ragonese), N.F., V.S., A.F., A.L.P., B.R., M.G., G.G., V.P., C.F., E.F.A., A.S., A.T. and C.D.N.; methodology, R.L.; software, A.C. and R.L.; validation, M.R. (Matteo Romagnoli), R.L. and C.D.N.; formal analysis, V.S., A.F., A.L.P., B.R., M.G., G.G., V.P., C.F., E.F.A., A.S., A.T. and C.D.N.; investigation, V.S., A.F., A.L.P., B.R., M.G., G.G., V.P., C.F., E.F.A., A.S., A.T. and C.D.N.; resources, A.C., P.S., R.L., M.B.S., E.R., M.R. (Mauro Ragonese) and S.D.C.; data curation, V.P., C.F., E.F.A., A.S., A.T. and C.D.N.; writing—original draft preparation, P.S., R.L., M.B.S., E.R., M.R. (Matteo Romagnoli), S.D.C., E.C., D.A., and N.F.; writing—review and editing, M.R. (Matteo Romagnoli), V.S., A.F., A.L.P., B.R., M.G., G.G., V.P., C.F., and E.F.A.; visualization, A.T.; supervision, V.S., A.F., A.L.P., B.R., M.G., G.G., V.P., C.F., E.F.A., A.S., A.T. and C.D.N.; funding acquisition, Not applicable. All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Institutional Review Board Statement
The study was conducted in accordance with the Declaration of Helsinki, and approved by the Institutional Review Board of Ospedale Sant’Andrea Rome Italy (14085) on 14 October 2021.
Informed Consent Statement
Written informed consent has been obtained from the patients to publish this paper.
Data Availability Statement
The raw data supporting the conclusions of this article will be made available by the authors on request.
Acknowledgments
We acknowledge the members of the Next Gen Research Group.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Kim, J.K.; Dos Santos, J.; Rickard, M.; Lorenzo, A.J. Review—Renal transplantation for congenital urological diseases. J. Pediatr. Urol. 2024, 20, 990–997. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Puerto Nino, A.K.; Garcia Perez, V.; Secco, S.; De Nunzio, C.; Lombardo, R.; Tikkinen, K.A.O.; Elterman, D.S. Can ChatGPT provide high-quality patient information on male lower urinary tract symptoms suggestive of benign prostate enlargement? Prostate Cancer Prostatic Dis. 2025, 28, 167–172. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kotsifa, E.; Mavroeidis, V.K. Present and Future Applications of Artificial Intelligence in Kidney Transplantation. J. Clin. Med. 2024, 13, 5939. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Alamgir, A.; Hussein, H.; Abdelaal, Y.; Abd-Alrazaq, A.; Househ, M. Artificial Intelligence in Kidney Transplantation: A Scoping Review. Stud. Health Technol. Inform. 2022, 294, 254–258. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Rawashdeh, B.; Kim, J.; AlRyalat, S.A.; Prasad, R.; Cooper, M. ChatGPT and Artificial Intelligence in Transplantation Research: Is It Always Correct? Cureus 2023, 15, e42150. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lombardo, R.; Gallo, G.; Stira, J.; Turchi, B.; Santoro, G.; Riolo, S.; Romagnoli, M.; Cicione, A.; Tema, G.; Pastore, A.; et al. Quality of information and appropriateness of Open AI outputs for prostate cancer. Prostate Cancer Prostatic Dis. 2025, 28, 229–231. [Google Scholar] [CrossRef] [Scilit] [PubMed]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Published by MDPI on behalf of the Société Internationale d’Urologie. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.