Next Article in Journal
Correction: Patinen et al. Caries Experience and Erosive Tooth Wear in Finnish Men Conscripts 2021: A Cross-Sectional Study. Dent. J. 2022, 10, 122
Next Article in Special Issue
Copper Accumulation in the Lips of Brass Players: Case Report of a Rare Phenomenon
Previous Article in Journal / Special Issue
Calculus as a Risk Factor for Periodontal Disease: Narrative Review on Treatment Indications When the Response to Scaling and Root Planing Is Inadequate
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Comparative Evaluation of Two Bracket Systems’ Bond Strength: Conventional and Self-Ligating

1
Faculty of Dental Medicine, GEP University of Medicine Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
2
Raluca Ripan Chemistry Research Institute, Babes Bolyai University, 400294 Cluj-Napoca, Romania
3
Faculty of Dental Medicine, University of Porto, 4200-393 Porto, Portugal
*
Author to whom correspondence should be addressed.
Dent. J. 2022, 10(10), 196; https://doi.org/10.3390/dj10100196
Submission received: 14 August 2022 / Revised: 26 September 2022 / Accepted: 19 October 2022 / Published: 21 October 2022
(This article belongs to the Special Issue Dentistry Journal: 10th Anniversary)

Abstract

:
Adhesion remains a key element in dentistry, whether approached in prosthetics, odontology, or orthodontics. It is a continuously researched aspect, as improved materials and adhesive methods keep emerging in the market. No orthodontic treatment can be effective without the proper adhesion strength of the bonded elements on the teeth. The objective of this research, in the broad context of self-ligating versus conventional brackets, was to compare active and passive self-ligating systems with a conventional one by conducting an in vitro study on human-extracted premolars. Shear bond strength tests were executed by means of an advanced materials-testing machine that generated maximum load and tensile strength values. The data obtained underwent statistical analysis with a statistical threshold of p < 0.05. The results regarding the statistical significance were acquired when comparing the passive self-ligating system with the active self-ligating and conventional systems (load-at-maximum-load mean 204.9, SD 91.09, and p < 0.05). In this study, the passive self-ligating bracket system appears to present increased shear bond strength.

1. Introduction

In the vast field of bracket features, adhesion remains an important aspect to be taken into consideration. Whether it is a characteristic that determines the choice of system remains the practitioner’s personal decision.
Adhesive interfaces have a critical impact on clinical success in dentistry and interface durability can be quantified by in vitro tests [1,2,3]. Shear bond strength testing is appropriate for testing orthodontic materials that are bonded to enamel. More than 1000 studies have been performed that analyze the different factors influencing the bond strength of orthodontic brackets [4].
Research has evaluated different bond strength variables including the surface (enamel, metal, and ceramic), adhesive system (glass ionomer and composite), bracket material (stainless steel), and type (self-ligating, conventional, and lingual), together with the type of bracket base examination, the placement force, the surface pretreatment, or the enamel’s contamination with saliva or blood [5,6,7,8,9,10].
Additionally, few clinical studies have been performed that assess this aspect using in vivo debonding devices and comparing the results with in vitro studies [11,12]. Furthermore, clinical bond failure is a multifactorial issue that must be taken into consideration when assessing adhesion. The related risk factors include the bracket material, placement site, type of anomaly (overjet, overbite, and dental classification), patient age, oral hygiene, and treatment phase [13,14].
There are two types of self-ligating brackets: active and passive. Active self-ligating brackets apply an active force on the archwire through a spring clip that maintains it in the slot. Passive self-ligating brackets have an additional slide that once locked does not affect the slot and does not express any active forces on the archwire, transforming the bracket into a tube [15,16]. Conventional brackets maintain the archwire by means of replaceable stainless steel or elastomeric ligatures. Self-ligating brackets are bulkier than conventional brackets and, together with the bracket base’s design, this can influence the adhesion to enamel [17,18].
In order to test the bond strength, usually, a shear force is applied in a testing machine with a certain crosshead speed until the failure of the adhesive system. The debonding force is registered in newtons/megapascals (interface stress units).
There are no clear guidelines in the literature regarding bond strength limits but the material should permit good adhesion to sustain masticatory forces (5–10 MPa minimum shear bond strength) [19] and not exert excessively strong adhesion forces that can lead to enamel loss when debonding (40–50 MPa) [20].
The purpose of this in vitro study was, thus, to compare active and passive self-ligating bracket systems with a conventional one with respect to shear bond strength. The null hypothesis is that there is no significant difference between their enamel adhesion properties.

2. Materials and Methods

A total of 84 stainless-steel maxillary first bicuspid brackets (n = 84) were bonded on 84 extracted teeth with the use of the following brackets: 28 conventional brackets, 28 active self-ligating brackets, and 28 passive self-ligating brackets. The systems utilized were Master Series (metallic conventional Roth 0.022-inch slot, American Orthodontics, Sheboygan, WI, USA), Empower 2 Interactive (active), and passive self-ligating brackets (metallic Roth 0.022-inch slot, American Orthodontics, Sheboygan, WI, USA).
The extracted teeth were acquired from the oral and maxillofacial surgery department of the GEP University of Medicine, Pharmacy, Science, and Technology of Targu Mures with the approval of the Ethics Committee (No. 1779 from 10.06.2022). Only teeth with intact enamel and proper anatomical buccal surfaces for suitable bicuspid bracket bonding were included. A sample tooth can be seen in Figure 1.
Teeth with fillings, scale, cavities, large white spot lesions, cracks on the buccal sides, or less than two thirds of the roots present were excluded [21]. They were thoroughly cleaned with saline solution after all organic material had been removed and preserved in artificial saliva after extraction. Artificial saliva composition can be seen in Table 1. It comprised water, hydrochloric acid, calcium chloride, sodium bicarbonate, and disodium phosphate.
The teeth were brushed without toothpaste, etched with Blue Etch (36% orthophosphoric acid, Cerkamed, Stalowa Wola, Poland) for 20 s, rinsed, and dried (notice Figure 2 and Figure 3). The brackets were bonded using Orthosolo Universal Bond Enhancer, Ormco, and Transbond XT composite, 3M. They were light-cured separately with Woodpecker iLed for 3 s after the excess material was removed.
For 1 month, the teeth were conserved again in artificial saliva until the measurements were performed (as can be seen in Figure 4).
The vast majority of studies have been performed using brackets bonded to bovine teeth [22,23,24]. Although bovine enamel has been described to be a reliable replacement for human enamel in bonding research, this study was conducted using human premolar teeth for better accuracy [22]. Furthermore, the teeth were preserved in artificial saliva to better simulate the intra-oral environment [25].
We could not identify any studies in the literature that compared active and passive self-ligating brackets regarding bonding strength nor any study that focused solely on the brackets utilized in this research.
Bond strength was measured by applying an American Society for Testing and Materials D638 compression test of a Lloyd type LR5K Plus Dual-Column mechanical testing machine (Ametek, Lloyd Instruments, Meerbusch, Germany), with a 5 KN maximal approved capacity. The device is equipped with an electronic compression force measurement and transmission structure. For reproducibility, the selected basic settings can be seen in Table 2.
Data processing was performed in NexygenPlus software.
Each tooth with the bonded bracket was firmly placed in a load cell that was locked into the lower hydraulic grip in a fixed, repeatable position. The upper hydraulic grip with a metal pin in place would perpendicularly press against the bracket between the wings and the base at the selected crosshead speed, as can be seen in Figure 5 and Figure 6 [26,27].
All actions and measurements were performed by the same operator.
The maximum stress a material can tolerate when being pulled or stretched before breakage represents its tensile strength. It is calculated by executing a tensile test and registering the stress–strain curve, wherein the uppermost point of is the tensile strength [28,29]. It is quantified as force per area unit. The unit is the Pa, pascal, or a multiple, MPa, megapascal. Equivalently, it is measured in N/m2—newtons per square meter [30].
The maximum load is the load limit that a body can withstand safely. It is the load at which the structure is in a state of initial plastic collapse. Plasticity spreads throughout the structure and at the maximum load, the plastic zone becomes large, and the component is considered to have collapsed. In physics, it is measured in N, newtons [31].
The computer displayed the stress–strain graphic and the load at maximum load and tensile strength values. A total of 84 measurements were performed, one for each bracket-tooth couple: twenty-eight for the conventional brackets (CB), 28 for the active self-ligating brackets (ASLB), and 28 for the passive self-ligating brackets (PSLB). The values obtained were compared as follows:
  • ASLB vs. PSLB;
  • ASLB with CB;
  • PSLB with CB.
The statistical analysis included inferential statistics and descriptive statistics elements: mean, median, and standard deviation. The Shapiro–Wilk test was applied to determine the analyzed data series distribution. For non-normal distributions, for median comparison, the Kruskal–Wallis test and Dunn’s Multiple Comparison Test as a post hoc test were performed. We used Univariate Analysis of Variance to calculate the post hoc Power of the sample size. The significance level for the p-value was 0.05. The statistical analysis was accomplished in the demo version of GraphPad Prism utility program [32].

3. Results

Table 3 comprises the means, medians, and standard deviations of each of the three comparison groups for both the tensile strength and load-at-maximum-load measured values. The detailed statistical tables, as well the crosshead speed tables with all the performed measurements, are accessible on request.
Using the Univariate Analysis of Variance, for tensile strength, the post hoc power of a sample size with 28 subjects in each group is 15.8%, meaning there is a 15.8% chance to detect a difference between the values in the three groups.
For the load at maximum load, the post hoc power of a sample size with 28 subjects in each group is 72.4%, meaning there is a 72.4% chance to detect a difference between the values in the three groups [33].
The Kruskal–Wallis test showed that there is no statistically significant difference between the medians of the tensile strength values in ASLB, PSLB, and CB (p > 0.05).
The Kruskal–Wallis test also showed that there is a statistically significant difference between the medians of the load-at-maximum-load values in ASLB, PSLB, and CB. Clinically, this can indicate an increased bond strength in the passive system (p < 0.05).
The results of Dunn’s Multiple comparison post hoc test are given in Table 4.
Statistically significant differences were found when comparing the passive self-ligating system with the active self-ligating system and the conventional system.

4. Discussion

Naturally, the adhesive system is of paramount importance when discussing this topic. In a comparative four-adhesive study, Transbond XT attained the highest bonding strength [34]. The same result was obtained when comparing two different bracket bases [8].
The existing research mainly focuses on different types of materials when comparing the bracket shear bond strengths. Ceramic brackets present a significantly lower bond strength when compared to stainless-steel brackets [35]. Another study concluded that ceramics composed primarily of zirconia should be treated with at least three coats of methacryloyloxy-decyl dihydrogen phosphate primer in order to manifest a bond strength similar to that of a silica-rich ceramic treated with hydrofluoric acid and silane. The study was performed on orthodontic tubes [36].
Bonding orthodontic brackets on zirconia restorations is still a clinical challenge. Pretreatment with silica-coated alumina and applying RelyX or Clearfill ceramic primer provided sufficiently high shear bond strength values [37].
Increasing brackets’ shear bond strength is of great of interest. Enamel surface deproteinization with sodium hypochlorite before etching increased the bond strength of glass ionomer cement to similar values of Transbond XT, potentially reducing the incidence of white spot lesions [38]. Pretreating enamel with an Er,Cr:YSGG laser and CPP-ACP as a preventive measure before bonding brackets does not reduce bond strength [26]. Still, Er:YAG laser irradiation does not represent an option for enamel conditioning according to Contreras-Bulnes et al. [39]
Phosphoric acid produced a more aggressive etching pattern when compared to polyacrylic acid and self-etching primers, but the shear bond strength was not significantly influenced by the adhesive system or etching pattern [40]. Enamel deproteinization with sodium hypochlorite enhanced the bond strength in metal brackets but there was no statistically significant difference among the groups treated or untreated with this substance [41].
Fluoride pretreatment applied on eroded enamel before bracket bonding leads to a decrease in shear bond strength, while a fluoride-releasing adhesive can increase bonding to eroded surfaces [42]. In addition, the pretreatment of enamel with erythritol could represent a feasible method to reduce the failure rate in brackets [43].
In another study, airborne particle abrasion with aluminum trioxide and silica coating followed by silanization provided the highest bond strength when bonding polycarbonate brackets to ceramic [44]. Glass ionomer cement enriched with nano-titanium particles is a promising material due to its durability with respect to withstanding mastication forces and potential antibacterial activity [9]. Applying the OrthoPrimer bonding agent instead of XT Primer (3M) provided a higher bond strength of sandblasted polycarbonate bracket bases to enamel, thus making debonding more difficult and causing fractures of the bracket wings [45]. Exerting a sustained sealing force when bonding orthodontic brackets improves the adhesive layer’s quality and increases bond strength but does not influence the adhesive remanent index score distribution [6]. The combination of hydro-abrasion and acid etching significantly increased the shear bond strength values in orthodontic brackets [46].
In one study, an in-office reconditioning procedure of self-ligating brackets altered the shear bond strength but its values remained clinically acceptable [47].
Similar studies found increased shear bond strength values in self-ligating brackets when compared to conventional or other self-ligating brackets [7]. Northrup et al. conducted another study comparing two adhesives with conventional and self-ligating brackets and concluded that the Damon self-ligating system presented satisfactory shear bond strength with both adhesives (Transbond and Blugoo) [48]. Basaran and Ozer also found a clinically acceptable mean bond strength among two self-ligating systems and a conventional one but with no significant differences [33]. Sfondrini et al. arrived at similar outcomes [4].
In vitro study-associated limitations are to be taken into consideration when discussing the findings of this research. It is best that the results of this study and of similar studies be confirmed by clinical trials. A linear experiment cannot mimic the dynamic complex interactions that occur in the intra-oral three-dimensional environment. Furthermore, the operation of the LR5K machine was performed manually, which can lead to some degree of testing error. The lack of homogeneity in the methodology applied in multiple studies results in certain reservations regarding the interpretation of the comparative results. The interactive (active) and passive bracket systems from American Orthodontics present the same base design. The identification of statistically significant differences between the two in our research generated discussions on their source. As the results are linked to the tested materials, the resilience of the closing mechanism can represent a factor as the debonding pressure was applied at said mechanism’s level. Other bracket systems may present stiffer clips, but further studies should be conducted regarding this aspect. Is this of absolute importance if the bond strength is acceptable for finishing an orthodontic treatment? None of the methods described above have been applied to enhance enamel adhesion.
Thus, the null hypothesis is rejected.

5. Conclusions

Passive self-ligating brackets presented the highest shear bond strength, but all three systems presented suitable adhesion strength. Future clinical trials are required to support the findings of this research.

Author Contributions

Conceptualization, A.-C.V. and D.-C.S.; data curation, S.C.; formal analysis, D.-V.G.; methodology, M.P.; resources, M.M.; supervision, M.C.F.P.; writing—original draft, A.-C.V. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki, and approved by the Ethics Committee of the George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, Romania (No. 1779 from 10 June 2022).

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Carvalho, R.M.; Manso, A.P.; Geraldeli, S.; Tay, F.R.; Pashley, D.H. Durability of bonds and clinical success of adhesive restorations. Dent. Mater. 2012, 28, 72–86. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  2. Heintze, S.; Zimmerli, B. Relevance of in-vitro tests of adhesive and composite dental materials. A review in 3 parts. Part 2: Non-standardized tests of composite materials. Schweizer Monatsschrift für Zahnmedizin = Revue mensuelle suisse d’odonto-stomatologie = Rivista mensile svizzera di odontologia e stomatologia/SSO 2011, 121, 916–930. Available online: https://pubmed.ncbi.nlm.nih.gov/22025204/ (accessed on 28 June 2022).
  3. Söderholm, K.-J.M. Critical evaluation of adhesive test methods used in dentistry. J. Adhes. Sci. Technol. 2009, 23, 973–990. [Google Scholar] [CrossRef]
  4. Scribante, A.; Contreras-Bulnes, R.; Montasser, M.A.; Vallittu, P.K. Orthodontics: Bracket Materials, Adhesives Systems, and Their Bond Strength. BioMed Res. Int. 2016, 2016, 1329814. [Google Scholar] [CrossRef]
  5. Scribante, A.; Sfondrini, M.; Gatti, S.; Gandini, P. Disinclusion of unerupted teeth by mean of self-ligating brackets: Effect of blood contamination on shear bond strength. Med. Oral Patol. Oral Cir. Bucal 2013, 18, e162–e167. [Google Scholar] [CrossRef]
  6. Montasser, M.A. Effect of applying a sustained force during bonding orthodontic brackets on the adhesive layer and on shear bond strength. Eur. J. Orthod. 2011, 33, 402–406. [Google Scholar] [CrossRef]
  7. Sfondrini, M.F.; Gatti, S.; Scribante, A. Shear bond strength of self-ligating brackets. Eur. J. Orthod. 2011, 33, 71–74. [Google Scholar] [CrossRef] [Green Version]
  8. Scribante, A.; Sfondrini, M.F.; Fraticelli, D.; Daina, P.; Tamagnone, A.; Gandini, P. The influence of no-primer adhesives and anchor pylons bracket bases on shear bond strength of orthodontic brackets. BioMed. Res. Int. 2013, 2013, 315023. [Google Scholar] [CrossRef] [PubMed]
  9. Garcia-Contreras, R.; Scougall-Vilchis, R.J.; Contreras-Bulnes, R.; Sakagami, H.; Morales-Luckie, R.A.; Nakajima, H. Mechanical, antibacterial and bond strength properties of nano-titanium-enriched glass ionomer cement. J. Appl. Oral Sci. 2015, 23, 321–328. [Google Scholar] [CrossRef] [Green Version]
  10. Lanteri, V.; Segù, M.; Doldi, J.; Butera, A. Pre-bonding prophylaxis and brackets detachment: An experimental comparison of different methods. Int. J. Clin. Dent. 2014, 7, 191–197. [Google Scholar]
  11. Pickett, K.L.; Sadowsky, P.L.; Jacobson, A.; Lacefield, W. Orthodontic in vivo bond strength: Comparison with in vitro results. Angle Orthod. 2001, 71, 141–148. [Google Scholar]
  12. Hassan, A. Shear bond strength of precoated orthodontic brackets: An in vivo study. Clin. Cosmet. Investig. Dent. 2010, 2, 41–45. [Google Scholar] [CrossRef] [Green Version]
  13. Khan, H.; Mheissen, S.; Iqbal, A.; Jafri, A.R.; Alam, M.K. Bracket Failure in Orthodontic Patients: The Incidence and the Influence of Different Factors. BioMed Res. Int. 2022, 2022, 5128870. [Google Scholar] [CrossRef]
  14. Sukhia, R.H.; Sukhia, H.R.; Azam, S.I.; Nuruddin, R.; Rizwan, A.; Jalal, S. Predicting the bracket bond failure rate in orthodontic patients: A retrospective cohort study. Int. Orthod. 2019, 17, 208–215. [Google Scholar] [CrossRef]
  15. Maizeray, R.; Wagner, D.; Lefebvre, F.; Lévy-Bénichou, H.; Bolender, Y. Is there any difference between conventional, passive and active self-ligating brackets? A systematic review and network meta-analysis. Int. Orthod. 2021, 19, 523–538. [Google Scholar] [CrossRef]
  16. Ludwig, B. Self-Ligating Brackets in Orthodontics: Current Concepts and Techniques; Thieme: Stuttgart, Germany, 2012. [Google Scholar]
  17. Bishara, S.E.; Soliman, M.M.A.; Oonsombat, C.; Laffoon, J.F.; Ajlouni, R. The effect of variation in mesh-base design on the shear bond strength of orthodontic brackets. Angle Orthod 2004, 74, 400–404. [Google Scholar] [PubMed]
  18. Sharma-Sayal, S.K.; Rossouw, P.E.; Kulkarni, G.V.; Titley, K.C. The influence of orthodontic bracket base design on shear bond strength. Am. J. Orthod. Dentofac. Orthop. 2003, 124, 74–82. [Google Scholar] [CrossRef]
  19. Reynolds, I.R. A review of direct orthodontic bonding. Br. J. Orthod. 1975, 2, 171–178. [Google Scholar] [CrossRef]
  20. Giannini, M. Ultimate tensile strength of tooth structures. Dent. Mater. 2004, 20, 322–329. [Google Scholar] [CrossRef]
  21. Bishara, S.E.; Gordan, V.V.; VonWald, L.; Olson, M.E. Effect of an acidic primer on shear bond strength of orthodontic brackets. Am. J. Orthod. Dentofac. Orthop. 1998, 114, 243–247. [Google Scholar] [CrossRef]
  22. Oesterle, L.J.; Shellhart, W.C.; Belanger, G.K. The use of bovine enamel in bonding studies. Am. J. Orthod. Dentofac. Orthop. 1998, 114, 514–519. [Google Scholar] [CrossRef]
  23. Soares, F.Z.M.; Follak, A.; da Rosa, L.S.; Montagner, A.F.; Lenzi, T.L.; Rocha, R.O. Bovine tooth is a substitute for human tooth on bond strength studies: A systematic review and meta-analysis of in vitro studies. Dent. Mater. 2016, 32, 1385–1393. [Google Scholar] [CrossRef] [PubMed]
  24. Yassen, G.H.; Platt, J.A.; Hara, A.T. Bovine teeth as substitute for human teeth in dental research: A review of literature. J. Oral. Sci. 2011, 53, 273–282. [Google Scholar] [CrossRef] [PubMed]
  25. Pytko-Polonczyk, J.J.; Jakubik, A.; Przeklasa-Bierowiec, A.; Muszynska, B. Artificial saliva and its use in biological experiments. J. Physiol. Pharmacol. 2017, 68, 807–813. [Google Scholar]
  26. Nabawy, Y.A.; Yousry, T.N.; El-Harouni, N.M. Shear bond strength of metallic brackets bonded to enamel pretreated with Er,Cr:YSGG LASER and CPP-ACP. BMC Oral Health 2021, 21, 306. [Google Scholar] [CrossRef] [PubMed]
  27. Sam, G. Evaluation of shear bond strength of orthodontic bracket after using various etching systems: An in vitro study. World J. Dent. 2021, 12, 107–110. [Google Scholar] [CrossRef]
  28. Wang, R.; Li, Y.; Lv, D.; Zhao, W.; Zhang, C.; Zachert, H.; Eichhoff, G.; Beroya-Eitner, M.A. Comparison of test methods for determining the tensile strength of soil and weak rocks. Front Earth Sci. 2022, 10, 835851. [Google Scholar] [CrossRef]
  29. Chica, J.C.; Díez, P.M.B.; Calzada, M.P. A new prediction method for the ultimate tensile strength of steel alloys with small punch test. Materials 2018, 11, 1491. [Google Scholar] [CrossRef] [Green Version]
  30. García, T.E.; Rodríguez, C.; Belzunce, F.J.; Suárez, C. Estimation of the mechanical properties of metallic materials by means of the small punch test. J. Alloys Compd. 2014, 582, 708–717. [Google Scholar] [CrossRef]
  31. Ambroziak, A. Archives of Civil Engineeringarchives of Civil Engineering. 2021. Available online: https://journals.pan.pl/dlibra/publication/137156/edition/119972/content.c (accessed on 28 June 2022).
  32. Vartolomei, A.C.; Serbanoiu, D.C.; Ghiga, D.V.; Moldovan, M.; Cuc, S.; Pollmann, M.C.F.; Pacurar, M. Comparative evaluation of two bracket systems’ kinetic friction: Conventional and self-ligating. Materials 2022, 15, 4304. [Google Scholar] [CrossRef]
  33. Başaran, G.; Özer, T. İki kendinden kilitli braketin bağlanma direncinin konvansiyonel bir braketle karşılaştırılması. Turk. J. Orthod. 2009, 22, 37–44. [Google Scholar] [CrossRef]
  34. Sharma, S.; Singh, G.; Singh, A.; Tandon, P.; Nagar, A. A comparison of shear bond strength of orthodontic brackets bonded with four different orthodontic adhesives. J. Orthodont. Sci. 2014, 3, 29. [Google Scholar] [CrossRef]
  35. Chalipa, J.; Jalali, Y.F.; Gorjizadeh, F.; Baghaeian, P.; Hoseini, M.H.; Mortezai, O. Comparison of bond strength of metal and ceramic brackets bonded with conventional and high-power LED light curing units. J. Dent. 2016, 13, 423–430. [Google Scholar]
  36. Milagres, F.D.S.A.; Oliveira, D.D.; Silveira, G.S.; Oliveira, E.D.F.F.; Antunes, A.N.D.G. Bond strength and failure pattern of orthodontic tubes adhered to a zirconia surface submitted to different modes of application of a ceramic primer. Materials 2019, 12, 3922. [Google Scholar] [CrossRef] [Green Version]
  37. Jungbauer, R.; Proff, P.; Edelhoff, D.; Stawarczyk, B. Impact of different pretreatments and attachment materials on shear bond strength between monolithic zirconia restorations and metal brackets. Sci. Rep. 2022, 12, 8514. [Google Scholar] [CrossRef]
  38. Justus, R.; Cubero, T.; Ondarza, R.; Morales, F. A new technique with sodium hypochlorite to increase bracket shear bond strength of fluoride-releasing resin-modified glass ionomer cements: Comparing shear bond strength of two adhesive systems with enamel surface deproteinization before etching. Semin. Orthod. 2010, 16, 66–75. [Google Scholar] [CrossRef] [Green Version]
  39. Contreras-Bulnes, R.; Scougall-Vilchis, R.J.; Rodríguez-Vilchis, L.E.; Centeno-Pedraza, C.; Olea-Mejía, O.F.; Alcántara-Galena, M.D.C.Z. Evaluation of self-etching adhesive and Er:YAG laser conditioning on the shear bond strength of orthodontic brackets. Sci. World J. 2013, 2013, 719182. [Google Scholar] [CrossRef] [Green Version]
  40. Shinya, M.; Shinya, A.; Lassila, L.V.J.; Gomi, H.; Varrela, J.; Vallittu, P.K.; Shinya, A. Treated enamel surface patterns associated with five orthodontic adhesive systems-surface morphology and shear bond strength. Dent. Mater. J. 2008, 27, 1–6. [Google Scholar] [CrossRef] [Green Version]
  41. Pereira, T.B.J.; Jansen, W.C.; Pithon, M.M.; Souki, B.Q.; Tanaka, O.M.; Oliveira, D.D. Effects of enamel deproteinization on bracket bonding with conventional and resin-modified glass ionomer cements. Eur. J. Orthod. 2013, 35, 442–446. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  42. Althagafi, N. Impact of fluoride-releasing orthodontic adhesives on the shear bond strength of orthodontic brackets to eroded enamel following different surface treatment protocols. J. Orthodont. Sci. 2022, 11, 3. [Google Scholar] [CrossRef]
  43. Scribante, A.; Gallo, S.; Pascadopoli, M.; Catalano, F.; Gandini, P.; Sfondrini, M.F. Effect of different enamel pretreating agents on bonding efficacy and survival rates of orthodontic brackets: In vitro study and split-mouth randomized clinical trial. Am. J. Orthod. Dentofac. Orthop. 2022, 162, 297–306. [Google Scholar] [CrossRef]
  44. Özcan, M.; Vallittu, P.K.; Peltomäki, T.; Huysmans, M.C.; Kalk, W. Bonding polycarbonate brackets to ceramic: Effects of substrate treatment on bond strength. Am. J. Orthod. Dentofac. Orthop. 2004, 126, 220–227. [Google Scholar] [CrossRef]
  45. Pithon, M.M.; Oliveira, M.V.D.; Ruellas, A.C.D.O.; Bolognese, A.M.; Romano, F.L. Shear bond strength of orthodontic brackets to enamel under different surface treatment conditions. J. Appl. Oral. Sci. 2007, 15, 127–130. [Google Scholar] [CrossRef] [PubMed]
  46. Tepedino, M.; Potrubacz, M.I.; Arrizza, L.; Russo, M.; Cavarra, F.; Cordaro, M.; Chimenti, C. In vitro shear bond strength of orthodontic brackets after enamel conditioning with acid etching and hydroabrasion. Dent. J. 2020, 8, 108. [Google Scholar] [CrossRef]
  47. Sfondrini, M.F.; Xheka, E.; Scribante, A.; Gandini, P.; Sfondrini, G. Reconditioning of self-ligating brackets. Angle Orthod. 2012, 82, 158–164. [Google Scholar] [CrossRef]
  48. Northrup, R.G.; Berzins, D.W.; Bradley, T.G.; Schuckit, W. Shear bond strength comparison between two orthodontic adhesives and self-ligating and conventional brackets. Angle Orthod. 2007, 77, 701–706. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Extracted premolar.
Figure 1. Extracted premolar.
Dentistry 10 00196 g001
Figure 2. Etched premolars.
Figure 2. Etched premolars.
Dentistry 10 00196 g002
Figure 3. Rinsed and dried premolars.
Figure 3. Rinsed and dried premolars.
Dentistry 10 00196 g003
Figure 4. Teeth with bonded brackets in artificial saliva.
Figure 4. Teeth with bonded brackets in artificial saliva.
Dentistry 10 00196 g004
Figure 5. Setup for the test.
Figure 5. Setup for the test.
Dentistry 10 00196 g005
Figure 6. Pin pressing on conventional bracket.
Figure 6. Pin pressing on conventional bracket.
Dentistry 10 00196 g006
Table 1. Percentage components of artificial saliva.
Table 1. Percentage components of artificial saliva.
Composition%
Na2HPO40.3
NaHCO3
CaCl2
HCl-1M0.3
H2O99.4
Table 2. Testing machine settings.
Table 2. Testing machine settings.
DirectionTension
Preload/stress0.5 N
Preload/stress Speed1 mm/min
Automatically zero at the start of the testLoad extension
Test speed–Extension rate1 mm/min
Table 3. Mean, Median and SD.
Table 3. Mean, Median and SD.
ASLB (n = 28)PSLB (n = 28)CB (n = 28)p-Value
Tensile Strength
Median10.8413.9411.070.3474
Mean11.8914.0313.35
Std. Deviation7.0856.3707.750
Load at Maximum Load
Median139.3205.8116.60.0114
Mean153.0204.9140.7
Std. Deviation90.8191.0981.66
Table 4. Dunn’s Multiple Comparison Test.
Table 4. Dunn’s Multiple Comparison Test.
Dunn’s Multiple Comparison Test p-Value
Tensile Strength
ASLB versus PSLB0.1425
ASLB versus CB0.5830
PSLB versus CB0.4173
Load at Maximum Load
ASLB versus PSLB0.0373
ASLB versus CB0.5830
PSLB versus CB0.0052
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Vartolomei, A.-C.; Ghiga, D.-V.; Serbanoiu, D.-C.; Moldovan, M.; Cuc, S.; Pacurar, M.; Pollmann, M.C.F. Comparative Evaluation of Two Bracket Systems’ Bond Strength: Conventional and Self-Ligating. Dent. J. 2022, 10, 196. https://doi.org/10.3390/dj10100196

AMA Style

Vartolomei A-C, Ghiga D-V, Serbanoiu D-C, Moldovan M, Cuc S, Pacurar M, Pollmann MCF. Comparative Evaluation of Two Bracket Systems’ Bond Strength: Conventional and Self-Ligating. Dentistry Journal. 2022; 10(10):196. https://doi.org/10.3390/dj10100196

Chicago/Turabian Style

Vartolomei, Aurel-Claudiu, Dana-Valentina Ghiga, Dan-Cosmin Serbanoiu, Marioara Moldovan, Stanca Cuc, Mariana Pacurar, and Maria Cristina Figueiredo Pollmann. 2022. "Comparative Evaluation of Two Bracket Systems’ Bond Strength: Conventional and Self-Ligating" Dentistry Journal 10, no. 10: 196. https://doi.org/10.3390/dj10100196

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop