Shoreline Distance-Based Tsunami Fragility Curves for Steel Moment-Resisting Frame Buildings

,
and
1
Escuela de Ingeniería Civil, Pontificia Universidad Católica de Valparaíso, Brasil Ave. 2950, Valparaíso 2340025, Chile
2
Escuela de Ingeniería Oceánica, Universidad de Valparaíso, Valparaíso 2362844, Chile
3
Center for Interdisciplinary Research on Disaster Risk, Resilience and Recovery (CIGIDEN R+), Vicuña Mackenna 4860, Santiago de Chile 7820436, Chile
4
Centro de Observación Marino para Estudios de Riesgos del Ambiente Costero (COSTAR), Valparaíso 2362844, Chile

Abstract

This study develops collapse fragility curves for a representative steel moment-resisting frame building exposed to idealized tsunami-loading scenarios, explicitly incorporating shoreline distance as an organizing spatial variable. Nonlinear static analyses are performed in SeismoStruct for braced and unbraced configurations, using the maximum interstory drift ratio as the engineering demand parameter. Drift-based damage states are defined according to ASCE 41-23 and FEMA 356 to interpret damage progression, while the probabilistic formulation focuses on the collapse limit state using a lognormal model with total dispersion based on FEMA P695. Triangular and rectangular tsunami-load distributions are considered to assess the influence of load-pattern assumptions. The braced model remains below global collapse within the analyzed intensity range and is retained as a comparative case, whereas the unbraced model reaches global instability and provides the collapse-response information used to construct the fragility curves. The median collapse inundation depth is approximately 14.1 m for the triangular distribution and 11.7 m for the rectangular distribution, corresponding to shoreline distances of approximately 97.5 m and 157.5 m, respectively. The results suggest that shoreline distance can support a spatial interpretation of collapse vulnerability for preliminary coastal-risk assessment, provided that the idealized and site-dependent nature of the adopted distance–depth–velocity scenarios is properly recognized.

1. Introduction

The structural response of infrastructure under tsunami loads has gained importance in recent decades due to sustained coastal urbanization, leading to a gradual improvement in design guidelines [1,2]. Although tsunamis may originate from different phenomena, their most destructive sources are associated with large megathrust earthquakes, such as those that occurred in the Indian Ocean in 2004, Chile in 2010, and Japan in 2011 [3,4]. Under such source type, tsunamis are long-wavelength waves generated by the sudden displacement of the seafloor, which, upon reaching the coast, produce severe actions on the built environment [5,6].
Damage in buildings observed in major events has shown that the response to tsunamis is conditioned by the flow intensity, structural typology, material, urban configuration, local topography, and relative location with respect to the shoreline. Post-event studies have extensively documented the effects of tsunamis on buildings, bridges, and infrastructure, identifying recurrent damage mechanisms and underscoring the need to improve the design and assessment criteria for coastal structures [7,8,9,10,11,12]. Likewise, several studies have shown that topography, location, and urban configuration may locally amplify or attenuate flow action, either by channeling the flow and increasing its velocity or by partially dissipating its energy through the presence of obstacles [13,14,15].
From the structural engineering standpoint, tsunami action should not be interpreted as a single hydraulic load, but rather as a combination of effects that may act simultaneously or sequentially on a building. These include hydrostatic forces produced by water accumulation around the structure, hydrodynamic forces associated with flow, impact loads due to debris transported by the water, and scour effects at the foundations, all mechanisms which have been incorporated into design standards such as ASCE 7-16 [16] and ASCE 7-22 [17].
The performance of steel structures under tsunami loading presents features of particular interest. Their high strength-to-weight ratio and inelastic deformation capacity generally provide good behavior under dynamic actions such as seismic loading; however, under tsunami flow, local pressure concentrations, channeling effects, and high demands may develop in specific parts of the resisting system [18]. Observations following the 2011 Japan tsunami showed that numerous steel frames remained standing, but experienced severe damage to cladding, facade panels, and nonstructural components, compromising building functionality and increasing the exposure of the resisting system to more severe hydrodynamic actions [19]. Similarly, debris impact is recognized as a relevant mechanism which induces localized damage capable of significantly impairing the overall structural performance [20,21]. In steel structures, slender elements may also be vulnerable to local buckling when subjected to high-velocity flow [18].
Probabilistic assessment of structural damage under tsunami loading has increasingly relied on fragility curves (FCs) relating hazard intensity to the probability of reaching or exceeding different damage states. These FCs have been developed using empirical, experimental, and analytical approaches, employing intensity measures such as inundation depth, flow velocity, or momentum flux [22,23]. In particular, FCs derived from post-event databases have proven highly useful for describing global trends in observed damage [24]. However, while FCs provide a valuable large-scale view of damage, they tend to be highly dependent on the event, the building stock analyzed, and the urban context from which the data were obtained.
Several complementary methodologies have also contributed to the understanding of structural responses under tsunami loading, including large-scale tests of container and debris impact on concrete walls [25,26,27,28], nonlinear static analyses for specific structures [29,30,31,32], ASCE 7-22’s energy grade line analysis (EGLA) for estimating flow depths and velocities [17], and probabilistic procedures based on Monte Carlo simulations [33]. Previous analytical studies have also compared nonlinear static and dynamic approaches for tsunami fragility assessment. Petrone et al. [34] evaluated constant-height pushover, variable-height pushover, and nonlinear time-history analyses for a reinforced concrete frame subjected to simulated tsunami inundation traces. Their results showed that variable-height pushover can provide a good approximation of engineering demand parameters and collapse fragility curves obtained from dynamic analyses, while also highlighting that simplified pushover methods may introduce bias in interstory drift and member shear demands. More recently, advanced statistical models, such as cumulative link models, have been incorporated to represent more consistently the transition between different damage states and to avoid nonphysical overlap between fragility curves [18].
Recent literature has further emphasized that tsunami design and assessment of engineered buildings require the combined consideration of hydraulic loading, debris effects, foundation-related mechanisms, and performance objectives. Macabuag et al. [35] provided a critical review of tsunami design procedures for engineered buildings, comparing Japanese and U.S. guidance and highlighting unresolved issues such as flow-regime effects, vertical load distributions, time-dependent loading, dynamic response, and earthquake–tsunami interaction. Robertson and Chock [36] described the technical background behind ASCE 7-16 Chapter 6, showing that its tsunami load expressions were developed from laboratory experiments, post-tsunami observations, and forensic analyses of structures damaged during the 2010 Chile and 2011 Tohoku events. In a complementary contribution, Chock [37] discussed tsunami-resilient building design using ASCE 7 and emphasized the role of structural engineering in integrating tsunami design provisions with local planning, vertical evacuation, and community resilience policies.
Recent studies have also advanced the analytical and numerical tools used to evaluate structural and community-level tsunami effects. Baiguera et al. [38] proposed a nonlinear pushover procedure for tsunami loading within the ASCE 7 framework, allowing both global lateral capacity and local component demand to be assessed. Aegerter and Robertson [30] extended this type of nonlinear static analysis to ETABS, showing its applicability in commercial software for targeted strengthening of buildings, while Baiguera et al. [39] compared distributed- and lumped-plasticity modeling strategies for tsunami pushover analysis consistent with ASCE 7-22. At the community scale, Koh et al. [40] developed a coupled tsunami-flow and debris-transport framework for shipping-container hazards, introducing tsunami-driven debris intensity measures and hazard maps. Doyle et al. [41] experimentally evaluated debris damming forces against elevated coastal structure columns and compared the results with ASCE 7-22 design loads, showing that debris-related coefficients and drag assumptions remain relevant sources of uncertainty. More recently, Abdelhafeez et al. [42] showed that tsunami-induced hydrodynamic forces and fragility curves are strongly affected by wave period, crest amplitude, number of wave cycles, Manning roughness, bathymetric slope, and shoreline distance, reinforcing the need for site-specific and parametric fragility models.
Large-scale experimental studies on tsunami inundation and overtopping at vertical sea walls have also shown that tsunami-length, non-breaking waves may produce forces predominantly governed by hydrostatic loading, whereas bore-induced impulsive loads can be large but very short-lived [43]. Although these results refer to coastal wall systems rather than building frames, they reinforce the importance of distinguishing between short-duration impact effects and longer-duration inundation demands when interpreting tsunami-induced structural response.
Despite these advances, there is still an important gap when it comes to explicitly linking structural vulnerability with the position of buildings within the inundation zone. Several authors have recognized that buildings located closer to the shoreline tend to be subjected to greater flow depths and higher velocities, which tend to be subsequently dissipated by friction, interaction with the terrain, and the presence of the urban fabric [24,44]. However, distance to the shoreline has often been treated as a contextual descriptor of damage rather than as an explicit parameter for the construction of structural fragility curves. Consequently, research aimed at including the shoreline distance as a key variable to represent expected damage severity in tsunami fragility curves remains limited.
This study addresses this gap by developing collapse fragility curves for a representative steel moment-resisting frame (SMRF) building in which shoreline distance is explicitly incorporated as an organizing spatial variable. Unlike conventional tsunami fragility formulations that are primarily expressed in terms of hydraulic intensity measures, such as inundation depth, flow velocity, or momentum flux, the proposed approach links global collapse probability with the relative position of the building within an idealized inundation profile. The intermediate damage states defined in the study are used to interpret the progression of structural damage and to identify the onset of increasingly severe response levels; however, the probabilistic fragility formulation presented herein is focused on the collapse limit state. In this sense, the original contribution of the study lies in connecting nonlinear structural response, collapse fragility assessment, and a geographically interpretable exposure variable that may support preliminary coastal-risk assessment, territorial planning, and mitigation strategies.

2. Methods

The methodology adopted in this study is based on the nonlinear numerical analysis of a steel building previously designed [45] to achieve adequate seismic performance through a braced frame system. To assess the influence of the lateral-resisting configuration under tsunami loading, the same reference structure is also analyzed without diagonal bracing. Different building positions relative to the shoreline are then defined and associated with prescribed inundation depths and flow velocities, and nonlinear static analyses are performed using SeismoStruct V2024 [46]. The structural response is characterized through the maximum interstory drift ratio, which is used as the engineering demand parameter for interpreting damage progression and constructing collapse fragility curves. Overall, the proposed analytical and parametric framework enables a systematic assessment of how spatial exposure and hydraulic demand affect nonlinear response and collapse fragility, expressed in terms of both inundation depth and shoreline distance. Figure 1 presents a summary of the methodology applied by the authors.
Figure 1. Methodology flowchart.

2.1. Reference Building and Numerical Model

The procedure begins with a previously developed three-dimensional structural model representing a typical steel frame building. The original structural design and three-dimensional model of the reference building were developed using Robot Structural Analysis V2024 [47], whereas the nonlinear tsunami analyses presented in this study were carried out in SeismoStruct [46]. The previously designed building is adopted as a consistent baseline with predefined member sections, gravity loads, and seismic design characteristics, allowing the study to focus on the influence of tsunami-loading scenarios and lateral-resisting configuration on nonlinear response and collapse fragility. Figure 2 depicts the building under study, together with the dimensions of its components.
Figure 2. Structural models considered in the study: (a) isometric view of the braced structure, (b) elevation view of the braced structure, (c) plan view of the braced structure, identical to that of the unbraced structure, (d) isometric view of the unbraced structure, and (e) elevation view of the unbraced structure.
To evaluate the nonlinear structural response of the building under tsunami loading, displacement-controlled nonlinear static analyses (i.e., pushover analyses) are performed. These analyses simulate the progressive increase of lateral forces representing the effect of tsunami flow on the façade of the structure. This procedure enables the construction of structural capacity curves describing the evolution of the system from the initial elastic stage to the development of plastic mechanisms and global collapse. A36 structural steel is selected for all elements because of its broad international use. The ASTM A36/A36M standard [48] is used to ensure that the modeled elements faithfully represent the behavior of a steel building subjected to extreme loads. Table 1 presents the mechanical properties of this type of steel.
Table 1. Summary of the properties of A36 steel.
In the numerical modeling process, each structural component is defined through a classification that allows the assignment of appropriate geometric, mechanical, and inelastic behavior properties. In this case, the model consists of beam-column elements representing columns, beams, and braces within the structural frame [46]. The elements are defined using the infrmDB category (inelastic frame elements with displacement-based formulation), accurately capturing the nonlinear behavior of steel by considering both bending and axial forces (Table 2).
Table 2. Beam-column element classes used in the structural model.
The numerical model is formulated as a global nonlinear finite-element frame model aimed at capturing the system-level response of the building, including lateral stiffness, interstory drift demand and global instability. Displacement-based inelastic beam-column elements with fiber sections are used to represent the nonlinear behavior of beams, columns, and braces. Within this modelling framework, the braced configuration corresponds to the reference structure originally designed for seismic performance, whereas the unbraced configuration provides a more flexible counterpart for evaluating the influence of the lateral-resisting system on tsunami-induced nonlinear response and collapse fragility.

2.2. Building Positions Relative to the Shoreline and Associated Tsunami Loading

Rather than using inundation depth alone as the primary intensity measure, this study adopts shoreline distance as the organizing spatial variable, linking tsunami demand to the position of the structure within the inundation zone. Eight building positions are analyzed at 50 m intervals from the shoreline, representing a gradual decrease in tsunami intensity as the flow propagates inland (Figure 3).
Figure 3. Schematic representation of the shoreline profile, showing the location of the structural model with respect to the sea and the corresponding inundation depths.
In this study, shoreline distance is defined as the inland distance measured from an idealized shoreline reference line. The selected distances are treated as parametric positions within a controlled inundation profile, with each position associated with prescribed inundation depth and flow velocity values. This definition provides a consistent basis for examining how spatial exposure influences tsunami-induced structural response and collapse fragility.
At each position, equivalent lateral tsunami loads are applied to the exposed façade of the structural model, with the corresponding vertical force distributions described in Section 2.3. For each shoreline-distance scenario, a displacement-controlled nonlinear static analysis is performed, and the maximum interstory drift ratio is obtained as the engineering demand parameter.
Different values of maximum inundation depth ( h m a x ) and maximum flow velocity ( u m a x ) are prescribed for the shoreline-distance scenarios considered in this study. These values define a controlled distance–depth–velocity profile representing the progressive attenuation of tsunami demand as the flow propagates inland. A selected flow velocity of 10.5 m/s is adopted for inundation depths equal to or greater than 6 m, while the velocity assigned to the 4 m inundation-depth case is limited to 9.4 m/s, following the velocity constraints considered in the tsunami-loading procedure based on ASCE 7-22. This definition provides a consistent framework for comparing structural response at different shoreline distances while maintaining compatibility with the parameters used in the nonlinear tsunami-analysis procedure. The complete set of adopted distance, inundation-depth, and flow-velocity values is summarized in Table 3.
Table 3. Simulation data for the different building position relative to the shoreline considered in the study.

2.3. Loading Idealization and Nonlinear Analysis Procedure

For each shoreline-distance scenario, the equivalent tsunami-induced lateral loads are computed from the prescribed maximum inundation depth ( h m a x ) and maximum flow velocity ( u m a x ), following the ASCE 7-22 tsunami-loading formulation. These parameters are combined with the affected façade width, building orientation relative to the flow, reference elevation, tsunami importance factor, closure coefficient, effective fluid density, and vertical force-distribution pattern, as summarized in Table 4. An effective fluid density of 1128 kg/m3 is adopted to represent sediment-laden tsunami flow within the equivalent hydrodynamic loading formulation.
Table 4. Tsunami loading parameters considered in the analysis.
The width of the affected area is the total width of the facade intercepting the flow, measured perpendicular to the water direction; this width enters linearly into the global drag force and determines the B / h ratio used to define the drag coefficient C d (Table 5), where B is the building width measured perpendicular to the flow direction and h is the flow depth above the ground level at the structure location.
Table 5. Drag coefficient for rectilinear structures, adapted from ASCE 7-22.
The global drag force at each floor is the lateral action at floor level that represents the net thrust caused by the imbalance of pressures between the exposed and sheltered sides of the building.
Among the input parameters summarized in Table 4, the affected façade width defines the portion of the building directly exposed to the tsunami flow and enters linearly into the equivalent global drag force. The tsunami importance factor scales the demand level associated with the Maximum Considered Tsunami, whereas the closure coefficient accounts for the fraction of the inundated vertical area effectively blocked by structural components.
The drag coefficient is adopted from the ASCE 7-22 provisions for rectilinear structures and is defined as a function of the ratio between building width and inundation depth. In this study, it is used as an equivalent code-based coefficient representing the global flow resistance of the exposed building façade within the tsunami-loading formulation.
The VDPO–CDPO workflow is implemented as a quasi-static equivalent nonlinear procedure. In Phase 1, the Variable Depth Pushover Analysis (VDPO) progressively updates the tsunami-induced lateral force computed from the prescribed inundation depth and flow velocity values. In Phase 2, the Constant Depth Pushover Analysis (CDPO) performs a deformation-controlled nonlinear static analysis starting from the state reached at the end of Phase 1, allowing the displacement capacity and damage progression of the structure to be evaluated under the selected tsunami-loading scenario.
The vertical distribution pattern determines how the total lateral tsunami force is assigned along the building height. The triangular and rectangular load distributions are used as bounding idealizations of tsunami-induced lateral demand (Figure 4). The triangular pattern concentrates a larger portion of the force in the lower stories, whereas the rectangular pattern distributes the demand more uniformly over the submerged height. Their comparison allows the influence of load-pattern assumptions on global structural response, damage progression, and collapse fragility to be assessed.
Figure 4. Distribution of the total tsunami force along the height of the building: (a) triangular distribution and (b) rectangular distribution. Adapted from [36].

2.4. Engineering Demand Parameter and Damage-State Definition

As the engineering demand parameter (EDP) we adopt the interstory drift, defined as the ratio of the relative displacement between two consecutive levels and the story height:
θ =   Δ i − Δ i − 1 h i
where Δ i and Δ i − 1 are the absolute horizontal displacements of the upper and lower stories and h i is the story height [49]. This parameter is widely used in the assessment of structural damage in frame systems because of its close relationship with plastic deformation in columns and other vertical members. In nonlinear models, this parameter facilitates the identification of progressive damage states and the point at which the structure reaches its limit of acceptable performance. The maximum interstory drift ( θ m a x ) is defined as the largest value among all story drifts obtained throughout the structure.
The maximum interstory drift ratio is adopted as the engineering demand parameter (EDP) because it provides a deformation-based measure of global structural response in frame systems. This parameter allows the progression from elastic behavior to inelastic deformation, severe damage, and global instability to be tracked consistently across the different shoreline-distance scenarios and vertical load-distribution patterns. Its use is therefore well suited to the collapse fragility formulation developed in this study, where the objective is to relate tsunami-induced lateral demand to system-level damage progression and collapse probability.
Table 6 shows the interstory drift values used to identify the level of damage and the collapse point of the analyzed steel structure under each building position relative to the shoreline. These limits are based on the provisions of ASCE 41-23 and FEMA 356, which describe the behavior of steel frames under different performance conditions. Low drift values correspond to elastic behavior or slight damage, whereas drifts greater than 2.5% indicate severe damage and a collapse-prevention condition. For drift exceeding 5%, the structure is considered to have reached collapse or global instability, consistent with the 6% limit established in ASCE 41-23 for structurally unacceptable behavior due to loss of dynamic stability. The classification used in SeismoStruct to represent the different structural damage states detected on each element during the simulations is shown in Table 7.
Table 6. Classification of damage states based on interstory drift ratio (%). Source: Adapted from ASCE 41-23 [1] and FEMA 356 [2].
Table 7. Visual classification of structural damage states applied in the analysis of the results. Source: ASCE 41-23 [1] and FEMA 356 [2].
In this study, global collapse is defined as a system-level instability condition governed by excessive lateral deformation. This limit state is identified during the nonlinear static analysis through the attainment of large interstory drift demands, progressive loss of lateral load-carrying capacity, and development of a global instability mechanism. From a structural standpoint, this response may involve amplification of lateral displacements due to P − Δ effects, concentration of inelastic demand in lower-story members, and reduction of the residual axial capacity of columns. Accordingly, the adopted collapse criterion provides a consistent basis for linking nonlinear structural response with the system-level fragility curves developed in this study.
The damage-state classification is used to characterize the progression of structural response as tsunami-induced demand increases. The slight, moderate, and severe damage states provide reference levels for identifying the evolution of yielding, stiffness degradation, and damage concentration in beams, columns, and braces. Within this framework, the collapse limit state is adopted as the target condition for the fragility formulation, while the preceding damage states support the interpretation of the nonlinear response and the transition toward global instability. The drift threshold associated with collapse defines the collapse point used to estimate the median collapse intensity in the lognormal fragility model.

2.5. Fragility Curve Formulation

Collapse fragility curves are built from data pairs relating the shoreline distance, the corresponding tsunami-loading intensity, and the attainment of the collapse limit state identified from the nonlinear structural response. Although intermediate damage states are defined in Section 2.4 to describe the progression of structural damage, the probabilistic formulation adopted in this study is restricted to collapse. This decision is consistent with the objective of evaluating global instability as a function of inundation depth and shoreline distance [50].
To capture the asymmetric nature of structural exceedance probabilities, the collapse fragility curves are fitted using cumulative lognormal distribution functions, which are widely adopted in seismic and tsunami fragility assessment: [23,50].
P x   = Φ ln x − λ ζ
where p ( x ) represents the probability of exceeding a damage state, x the shoreline distance (or by inundation depth), λ the logarithmic mean, related to the median IM producing damage; ζ the standard deviation of the natural logarithm of x ; and Φ the cumulative distribution function of a standard normal variable [50]. The parameter ζ is determined following the total uncertainty criterion proposed in FEMA P695 [5], which combines the main sources of variability of the structural system. Although this document was developed for seismic applications, its use is considered appropriate herein because tsunami loading is directly associated with a seismic event and is evaluated here from a structural-collapse perspective. The appropriate formulation includes this equation:
β t o t   =   β R T R 2 + β D R 2 + β T D 2 + β M D L 2
where β t o t represents the total system uncertainty (0.275–0.950), the uncertainty associated with record-to-record variability (0.20–0.40), the uncertainty associated with design requirements (0.10–0.50), β T D the uncertainty related to the quality of experimental data (0.10–0.50) and β M D L the uncertainty associated with the numerical model (0.10–0.50).
In accordance with FEMA P695, and considering a superior model quality (A) and period-based ductility, a value of β T O T = 0.425 was adopted and used directly as the standard deviation ( ζ ) in the lognormal function. This value represents a confidence level consistent with the quality of the analyzed structural model and with the β R T R value corresponding to the highest uncertainty level for records, which in this case may be considered consistent with the uncertainty associated with tsunami variability. In addition, to account for the variability of the fragility curves, a good model quality was considered while maintaining the maximum β R T R value, in order to assess the sensitivity of the fragility curves. Under this assumption, a value of β T O T = 0.529 was obtained and was also used to determine the collapse fragility curves.
The uncertainty treatment adopted in this study follows the FEMA P695 framework as a structured basis for incorporating dispersion into the collapse fragility formulation. Within this framework, the total dispersion combines the main sources of uncertainty associated with demand variability, design requirements, experimental data quality, and numerical modelling. For the present tsunami application, β R T R is used as a conservative representation of tsunami-demand variability, accounting for possible differences in source characteristics, wave height, arrival direction, inundation depth, flow velocity, and local flow conditions.
The baseline fragility formulation adopts β T O T = 0.425 , which includes β R T R = 0.40 and reflects a high level of demand variability within the adopted uncertainty framework. To examine the influence of a more conservative uncertainty treatment, an additional value of β T O T = 0.529 is considered by maintaining β R T R = 0.40 and increasing the remaining uncertainty components to β D R =   0.20 , β T D =   0.20 , and β M D L =   0.20 . Both dispersion values are used to evaluate the sensitivity of the collapse fragility curves to uncertainty in the probabilistic formulation.
The fragility functions are expressed in terms of both inundation depth and shoreline distance. Shoreline distance is used as the primary organizing spatial variable of the proposed framework, whereas inundation depth is retained as the associated hydraulic intensity measure for each building position. Equivalent shoreline distances associated with collapse are obtained through linear interpolation between the two adjacent building positions bracketing collapse for each load distribution. Although alternative tsunami intensity measures, such as peak tsunami-induced force, may provide a strong correlation with interstory drift demand in some structural configurations [35], the combined use of shoreline distance and inundation depth provides a spatially interpretable basis for preliminary vulnerability assessment.

3. Results

The results are presented in three consecutive stages. First, the global structural response is evaluated through base-shear versus roof-displacement curves, allowing the stiffness, strength, and deformation capacity of the braced and unbraced models to be compared. Second, the damage progression is examined through the structural damage states reached by the members under the different inundation depths and load-distribution patterns. Finally, the collapse fragility curves are derived from the scenarios in which the collapse limit state is reached, linking the nonlinear structural response to inundation depth and shoreline distance. This sequence provides a direct connection between capacity curves, observed damage patterns, and probabilistic collapse assessment.

3.1. Global Response of Braced and Unbraced Models

Figure 5 presents a compilation of the global response curves of roof displacement as a function of base shear for the braced structure, considering the inundation depths examined in this study. As expected, as the inundation depth increases, the applied forces become larger, greater roof displacements develop, and the structural response evolves from linear to nonlinear behavior.
Figure 5. Base shear versus roof displacement curves of the structure with diagonal bracing for a triangular distribution, for the different inundation depths considered in the study.
The rectangular distribution of forces over the facade of the braced building does not produce results that differ substantially from those obtained under the triangular distribution, as can be seen in Figure 6. Although the resulting forces on the exposed facade are somewhat greater in this case than under the triangular distribution, the effect is only slightly larger in terms of lateral displacements and nonlinear response at the greatest inundation depths.
Figure 6. Base shear versus roof displacement curves of the structure with diagonal bracing for a rectangular distribution, for the different inundation depths considered in the study.
A marked quantitative change is observed in the buildings modeled without braces, both for the triangular and rectangular force distributions. It is evident that, in the different positions, larger roof displacements are reached, indicating that the structural members begin to experience greater deformation demands, which ultimately translate into high ductility demands, as shown in Figure 7 and Figure 8.
Figure 7. Base shear versus roof displacement curves of the structure without diagonal bracing for a triangular distribution, for the different inundation depths considered in the study.
Figure 8. Base shear versus roof displacement curves of the structure without diagonal bracing for a rectangular distribution, for the different inundation depths considered in the study.
These global response curves provide the first indication of the different nonlinear behavior developed by the two structural configurations. While the braced model mainly exhibits limited deformation demand within the analyzed intensity range, the unbraced model shows larger roof displacements and a clearer transition toward inelastic behavior. To further interpret these differences, the following section examines the distribution and severity of damage states developed in the structural members for each inundation-depth scenario.

3.2. Damage Progression Under Tsunami Loading

Figure 9 and Figure 10 show the structural damage states reached by the members of the braced model for all inundation depths under triangular and rectangular tsunami-force distributions. In the positions a–e, elastic behavior is observed in the triangular distribution, with no significant formation of plastic hinges, whereas in the rectangular distribution this stage extends from positions a–d. As inundation depth increases (f–h) plastic hinges begin to form at the bases of columns and braces in the triangular distribution, while in the rectangular distribution this process starts from (e) onward, with the structure deforming gradually and mainly reflecting slight damage. Damage is concentrated primarily in the lower members, where the structure reaches more advanced states of damage while still maintaining a stable configuration due to the stiffness contribution provided by the braces.
Figure 9. Damage states of the structure with diagonal bracing, triangular distribution, including all inundation depths: (a) 4 m, (b) 6 m, (c) 8 m, (d) 10 m, (e) 12 m, (f) 14 m, (g) 16 m, and (h) 18 m.
Figure 10. Damage states of the structure with diagonal bracing, rectangular distribution, including all inundation depths: (a) 4 m, (b) 6 m, (c) 8 m, (d) 10 m, (e) 12 m, (f) 14 m, (g) 16 m, and (h) 18 m.
Figure 11 and Figure 12 present the damage states of the unbraced model for the same inundation depths under both triangular and rectangular distributions. In Figure 11b,c, plastic hinges are identified at the bases of the columns under the triangular distribution, indicating lower global stiffness, whereas in the rectangular distribution deformation becomes visible in some columns and beams from Figure 12a–d. As depth increases from Figure 11d–f, damage extends to upper levels and intensifies in beams and columns under the triangular distribution, while in the rectangular case deformations already increase noticeably from Figure 12d. Finally, in Figure 11g,h, extensive yielding zones are observed in the lower stories, showing a more flexible structural response and larger lateral deformations in the triangular distribution, whereas under the rectangular distribution collapse damage is already reached from Figure 12e–h.
Figure 11. Damage states of the structure without diagonal bracing, triangular distribution, including all inundation depths: (a) 4 m, (b) 6 m, (c) 8 m, (d) 10 m, (e) 12 m, (f) 14 m, (g) 16 m, and (h) 18 m.
Figure 12. Damage states of the structure without diagonal bracing, rectangular distribution, including all inundation depths: (a) 4 m, (b) 6 m, (c) 8 m, (d) 10 m, (e) 12 m, (f) 14 m, (g) 16 m, and (h) 18 m.
The damage patterns shown in Figure 9, Figure 10, Figure 11 and Figure 12 are used to interpret the progression of structural response from elastic behavior to increasingly severe damage and, ultimately, collapse. This interpretation provides the link between the global capacity curves presented in Section 3.1 and the collapse fragility curves developed in Section 3.3. Although the identification of pre-collapse damage thresholds provides useful information for future development of multi-state fragility functions, the present study focuses on collapse fragility curves. Therefore, slight, moderate, and severe damage states are discussed as indicators of damage progression, whereas the probabilistic curves presented in the following section are calculated only for the collapse limit state.

3.3. Fragility Curves as a Function of Inundation Depth and Shoreline Distance

This section presents the collapse fragility curves obtained from the nonlinear response and damage progression discussed in Section 3.1 and Section 3.2. As observed in the previous subsection, only the unbraced building model reached the collapse limit state within the range of inundation depths and flow velocities considered in this study. For the triangular vertical load distribution, collapse was identified at an inundation depth of 16 m (Figure 11g), whereas for the rectangular distribution collapse was identified at an inundation depth of 12 m in the first story (Figure 12e). The braced building model, by contrast, did not reach global collapse in any of the analyzed cases.
The braced model is retained as a comparative case for evaluating the influence of the lateral-resisting configuration on tsunami-induced structural demand. Within the analyzed range of inundation depths and flow velocities, this configuration remained below the global collapse limit state, evidencing limited inelastic progression and enhanced lateral stiffness. The unbraced model, in contrast, developed a clearer transition from elastic response to inelastic deformation and global instability, allowing the relationship between tsunami intensity, shoreline distance, and collapse probability to be established for the fragility functions presented in this section.
Although shoreline distance is the primary organizing variable in this study, collapse fragility curves are also expressed in terms of inundation depth, since each building position relative to the shoreline is associated with a corresponding inundation condition.
The logarithmic mean used in Equation (2) was obtained from the point at which the structure reaches collapse. In this case, a mean inundation depth of 14.1 m was determined for the triangular distribution (Figure 13), obtained by interpolation upon identifying the point at which the system loses global stability. For the unbraced building model, an interpolated median collapse inundation depth of 14.1 m was determined for the triangular vertical load distribution (Figure 13). The same procedure was followed for the rectangular distribution, for which a mean inundation depth of 11.7 m was obtained, see Figure 14. These values do not correspond to directly simulated inundation depths, but to interpolated median inundation depths associated with structural collapse.
Figure 13. Determination of the logarithmic mean (λ) for inundation depth and shoreline distance. Triangular distribution.
Figure 14. Determination of the logarithmic mean (λ) for inundation depth and shoreline distance. Rectangular distribution.
For the triangular distribution, the equivalent shoreline distance associated with collapse was 97.5 m. Once the inundation-depth values and their associated collapse probabilities had been obtained for the unbraced model, the corresponding collapse fragility curve was constructed. The relationship between inundation depth and exceedance probability is plotted in Figure 15, generating a lognormal fragility curve that describes the cumulative probability of the structure reaching or exceeding collapse as inundation depth increases. In a complementary manner, a fragility curve was also developed as a function of shoreline distance (Figure 16), describing the exceedance probability of the collapse limit state as the structure is located at increasing distances from the shoreline. Both figures include the curves determined with the β T O T values indicated in Section 2.5.
Figure 15. Collapse fragility curve of the structure without diagonal bracing as a function of inundation depth for (a) triangular and (b) rectangular distribution.
Figure 16. Collapse fragility curve of the structure without diagonal bracing as a function of shoreline distance for (a) triangular and (b) rectangular distribution.
The use of two dispersion values affects the shape of the fragility curves but not the median collapse inundation depth or the corresponding shoreline distance, since these median values are obtained from the nonlinear structural response and the interpolation of the collapse point. The larger dispersion value produces a smoother transition between low and high collapse probabilities, representing a broader uncertainty range in the probabilistic formulation. In this way, the collapse fragility curves integrate the main results of the nonlinear assessment: the global capacity curves describe the evolution of lateral deformation demand, the damage-state maps show the onset and progression of structural damage, and the identified collapse points define the median intensity values used to construct the lognormal fragility functions.

4. Discussion

4.1. Effect of Structural Configuration and Load Distribution

The results show that both structural configuration and the vertical load-distribution pattern have a decisive influence on the building response under tsunami loading. The comparison between braced and unbraced models, as well as between triangular and rectangular distributions, reveals clear differences in lateral stiffness, inelastic deformation capacity, and the distribution of damage along the building height. In general terms, the braced model exhibited a stiffer response, with smaller displacements and more localized damage, whereas the unbraced model shows a more flexible behavior and a more pronounced progression of damage. Likewise, the triangular distribution concentrates demand in the lower stories, while the rectangular distribution generates a more uniform demand over the building height.
The comparison between the braced and unbraced configurations highlights the role of lateral stiffness and bracing action in controlling tsunami-induced deformation demand. The braced model exhibited a predominantly elastic response over most of the analyzed tsunami-loading scenarios, with limited plastic development and damage concentrated in a few critical elements. This response reflects the contribution of the diagonal bracing system to lateral resistance and damage control within the selected intensity range.
The unbraced model, by contrast, exhibited larger lateral displacements, a clearer transition into the inelastic range, and a more progressive distribution of damage along the structural height. This configuration therefore provided a suitable response range for examining the evolution from elastic behavior to global instability and for constructing the collapse fragility curves. The contrast between both configurations shows how the lateral-resisting system influences stiffness, damage progression, and collapse vulnerability under equivalent tsunami-induced lateral demands. The comparison between load-distribution patterns also explains the differences observed in the collapse fragility curves. While the triangular distribution concentrates demand in the lower stories, the rectangular distribution mobilizes a larger portion of the structural height, leading to a more demanding global response and a lower median collapse inundation depth.

4.2. Relevance of Shoreline Distance for Tsunami Vulnerability Assessment

The results show that distance from the shoreline directly influences the severity of structural response, since as the building is located farther inland, inundation depth, flow velocity, and consequently hydrodynamic demand progressively decrease. For the building positions closest to the shoreline (0–100 m), the structure is subjected to the most severe loading conditions, with high collapse probabilities and a clearly nonlinear response characterized by large lateral displacements and the formation of plastic hinges in the lower stories. At intermediate distances (150 to 200 m), the structure enters the inelastic range without reaching collapse, whereas in the farthest positions (>250 m), the response remains essentially elastic, with low collapse probabilities and controlled deformations.
The comparison between loading patterns further confirms that the rectangular distribution systematically leads to a more demanding response than the triangular distribution for the same inundation level, resulting in higher collapse probabilities and a more conservative estimate of vulnerability. Consistent with this, For the unbraced model, collapse was associated with an interpolated median inundation depth of approximately 14.1 m in the triangular case and 11.7 m in the rectangular case (~97.5 m from the shoreline), whereas for the rectangular distribution collapse occurs at an inundation depth of ~11.7 m (~157.5 m from the shoreline).
The resulting fragility functions show a consistent relationship between inundation depth and shoreline distance within the adopted distance–depth–velocity profile. As tsunami demand decreases with increasing inland distance, the probability of collapse also decreases, providing a spatial interpretation of structural vulnerability that complements the conventional formulation based on inundation depth. The site-dependent implications of this relationship are further discussed in Section 4.3.

4.3. Scope and Limitations of the Proposed Analytical Framework

The shoreline-distance-based collapse fragility curves developed in this study should be interpreted within the idealized distance–depth–velocity profile adopted for the analysis. Shoreline distance is used as an organizing spatial variable to relate structural response to the relative position of the building within the inundation zone; however, it does not by itself define the tsunami hazard. In real coastal settings, the relationship between shoreline distance, inundation depth, and flow velocity may vary substantially depending on bathymetry, coastal morphology, ground elevation, slope, roughness, urban density, tidal level, flow obstruction, and tsunami arrival direction. For site-specific applications, this relationship should therefore be derived from local inundation modeling, tsunami hazard analysis, bathymetric and topographic data, or procedures such as Energy Grade Line Analysis. Future developments may also consider normalizing shoreline distance with respect to the maximum inundation extent or run-up distance to improve the transferability of the proposed approach.
The structural analyses performed herein correspond to global nonlinear assessments under equivalent tsunami-induced lateral loads. The VDPO–CDPO workflow is treated as a quasi-static equivalent nonlinear procedure and does not constitute a fully coupled tsunami–structure simulation. Therefore, the proposed curves should be interpreted as collapse fragility estimates under equivalent maximum lateral demand, rather than as predictions of the dynamic structural response produced by a complete time-dependent tsunami loading history. In particular, pressure–time histories, transient bore impact, dynamic amplification, local flow concentration around individual members, and feedback between structural deformation and fluid motion are not explicitly reproduced. Previous studies have shown that pushover-based procedures may become less reliable when the inundation force history includes multiple significant peaks or cyclic demand effects, such as double-peak tsunami force records [34]. Future work should therefore compare the proposed curves with nonlinear dynamic analyses based on representative pressure–time or force–time histories.
Several tsunami-related mechanisms are also outside the scope of the present framework. Discrete debris impact, debris damming, and localized damage caused by large floating objects are not explicitly modeled; the effective fluid density adopted in the loading formulation only represents sediment-laden flow in a simplified manner. Buoyancy effects are not considered, including vertical uplift, reduction of effective gravity load, retained-water effects, and partial loss of support. In addition, fixed-base boundary conditions are assumed, so tsunami-induced ground displacement, foundation flexibility, local scour, loss of soil support, and soil–structure interaction are not explicitly represented. These mechanisms may modify stability, foundation demands, and displacement capacity, particularly in near-shore locations or in earthquake–tsunami sequences. Experimental and post-event evidence also indicates that some relevant tsunami-induced failure mechanisms may be governed by load duration rather than by instantaneous peak pressure alone, including scour, sliding, overturning, uplift-related effects, and other structural or geotechnical responses sensitive to sustained hydrostatic loading and overtopping flow [43].
The structural model adopted in this study is a global nonlinear finite-element frame model, suitable for assessing system-level response in terms of interstory drift, lateral capacity, plastic-hinge development, and global instability. Nevertheless, it does not provide the same level of local detail as refined finite-element models based on shell or solid elements. Local flange or web buckling, connection-level stress concentrations, component-level pressure effects, residual axial-capacity degradation, detailed local column instability, and progressive-collapse mechanisms are therefore not explicitly captured. Accordingly, the fragility curves developed herein refer to global system-level collapse, not to isolated member failure. Under tsunami loading, exterior columns and lower-story members directly exposed to the flow may experience severe local demands before the full structural system reaches global instability, depending on redundancy and force redistribution capacity.
Finally, the position of the collapse fragility curves is influenced by the drift threshold adopted to identify the collapse limit state. In this study, this threshold is defined according to the performance-based criteria described in Section 2.4 and is applied consistently to all shoreline-distance scenarios and load-distribution patterns. A lower drift threshold would shift the curves toward lower inundation depths and larger shoreline distances, whereas a higher threshold would produce the opposite effect. Thus, the proposed curves are intended for preliminary analytical assessment of buildings with structural characteristics comparable to the case-study model and subjected to tsunami-loading conditions consistent with the adopted scenarios. Direct use of the curves for design or site-specific risk assessment would require recalibration using local inundation parameters, multiple tsunami scenarios representative of the target coastal area, and additional validation through experimental data, high-fidelity hydrodynamic simulations, refined structural models, or benchmark datasets.

5. Conclusions

This study evaluated the tsunami-induced nonlinear response and collapse fragility of a representative steel moment-resisting frame building using an analytical framework that explicitly incorporates shoreline distance as an organizing spatial variable. The analysis considered different inundation depths, vertical tsunami-load distributions, and lateral-resisting configurations to assess how spatial exposure and hydraulic demand influence damage progression and global instability.
The main contribution of the study is the formulation of collapse fragility curves expressed in terms of both inundation depth and shoreline distance. This dual representation complements conventional tsunami fragility approaches based primarily on hydraulic intensity measures, such as inundation depth, flow velocity, or momentum flux, by providing a spatial interpretation of collapse probability. In this sense, the proposed approach may support preliminary coastal-risk assessment, infrastructure siting, and territorial planning in tsunami-exposed areas.
The results show a consistent reduction in collapse probability as shoreline distance increases and tsunami demand decreases within the adopted distance–depth–velocity profile. For the unbraced model, the interpolated median collapse inundation depth was approximately 14.1 m for the triangular load distribution and 11.7 m for the rectangular load distribution, corresponding to shoreline distances of approximately 97.5 m and 157.5 m, respectively. The rectangular distribution produced more demanding conditions, leading to a lower median collapse depth and a more conservative estimate of vulnerability.
The comparison between braced and unbraced configurations highlights the influence of the lateral-resisting system on tsunami-induced nonlinear response. Within the analyzed range of inundation depths and flow velocities, the braced model remained below the global collapse limit state, evidencing limited inelastic progression and enhanced lateral stiffness. In contrast, the unbraced model developed larger lateral displacements, a clearer transition toward global instability, and the collapse-response information required to construct the fragility functions. These results confirm that structural configuration strongly affects damage progression and collapse vulnerability under equivalent tsunami-induced lateral demands.
The proposed curves should be interpreted within the assumptions of the analytical framework. Shoreline distance is not a universal tsunami intensity measure, since its relationship with inundation depth and flow velocity depends on site-specific conditions such as bathymetry, topography, roughness, urban configuration, tidal level, and tsunami propagation characteristics. Therefore, direct application to site-specific risk or design studies would require local inundation modelling, representative tsunami scenarios, and recalibration of the distance–depth–velocity relationship.
The framework also has modelling limitations. The analyses correspond to global nonlinear assessments under equivalent tsunami-induced lateral loads and do not represent a fully coupled tsunami–structure simulation. Pressure–time histories, dynamic amplification, debris impact and damming, buoyancy and uplift effects, retained-water loads, local scour, soil–structure interaction, earthquake-induced ground displacement, refined component-level failure mechanisms, and progressive collapse are outside the scope of the present study. Future work should address these aspects through refined structural and hydrodynamic models, nonlinear dynamic analyses, normalized shoreline-distance measures based on run-up or maximum inundation extent, sensitivity analyses of drift thresholds, and validation against experimental or high-fidelity numerical benchmark data.

Author Contributions

Conceptualization, I.A.-J. and J.C.V.; methodology, J.C.V.; software, I.A.-J., P.W. and J.C.V.; validation, P.W. and J.C.V.; formal analysis, I.A.-J. and J.C.V.; investigation, I.A.-J.; resources, P.W. and J.C.V.; data curation, P.W. and J.C.V.; writing—original draft preparation, I.A.-J.; writing—review and editing, P.W. and J.C.V.; visualization, P.W.; supervision, P.W. and J.C.V. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The research data are available in the authors’ files and may be provided to interested parties upon direct request by email.

Acknowledgments

The authors wish to express their gratitude to the Pontificia Universidad Católica de Valparaíso and the Universidad de Valparaíso, in whose facilities this research was carried out. Patricio Winckler gratefully acknowledge the financial support of the Center for Interdisciplinary Research on Disaster Risk, Resilience and Recovery (CIGIDEN R+), ANID/CIN250023.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. ASCE/SEI 41-23; Seismic Evaluation and Retrofit of Existing Buildings. American Society of Civil Engineers: Reston, VA, USA, 2023.
  2. Federal Emergency Management Agency (FEMA). FEMA 356: Prestandard and Commentary for the Seismic Rehabilitation of Buildings; American Society of Civil Engineers: Washington, DC, USA, 2000.
  3. Stolle, J.; Takabatake, T.; Nistor, I.; Mikami, T.; Nishizaki, S.; Hamano, G.; Ishii, H.; Shibayama, T.; Goseberg, N.; Petriu, E. Experimental investigation of debris damming loads under transient supercritical flow conditions. Coast. Eng. 2018, 138, 121–136. [Google Scholar] [CrossRef] [Scilit]
  4. Aguiniga, F.; Jaiswal, M.; Sai, J.; Cox, D.; Gupta, R.; van de Lindt, J. Experimental study of tsunami forces on structures. In Coastal Hazards; American Society of Civil Engineers: Reston, VA, USA, 2013; pp. 111–118. [Google Scholar] [CrossRef] [Scilit]
  5. Federal Emergency Management Agency (FEMA). Quantification of Building Seismic Performance Factors; FEMA: Washington, DC, USA, 2009.
  6. Karafagka, S.; Fotopoulou, S.; Pitilakis, K. Analytical tsunami fragility curves for seaport RC buildings and steel light-frame warehouses. Soil Dyn. Earthq. Eng. 2018, 112, 118–137. [Google Scholar] [CrossRef] [Scilit]
  7. Ghobarah, A.; Saatcioglu, M.; Nistor, I. The impact of the 26 December 2004 earthquake and tsunami on structures and infrastructure. Eng. Struct. 2006, 28, 312–326. [Google Scholar] [CrossRef] [Scilit]
  8. Fritz, H.; Petroff, C.; Catalán, P.; Cienfuegos, R.; Winckler, P.; Kalligeris, N.; Weiss, R.; Barrientos, S.; Meneses, G.; Valderas-Bermejo, C.; et al. Field survey of the 27 February 2010 Chile tsunami. Pure Appl. Geophys. 2011, 168, 1989–2010. [Google Scholar] [CrossRef] [Scilit]
  9. Robertson, I.; Chock, G.; Morla, J. Structural analysis of selected failures caused by the 27 February 2010 Chile tsunami. Earthq. Spectra 2012, 28, 215–243. [Google Scholar] [CrossRef] [Scilit]
  10. Zareian, F.; Aguirre, C.; Beltran, J.; Cruz, E.; Herrera, R.; Leon, R.; Millan, A.; Verdugo, A. Reconnaissance report of Chilean industrial facilities affected by the 2010 Chile offshore Bío-Bío earthquake. Earthq. Spectra 2012, 28, 513–532. [Google Scholar] [CrossRef] [Scilit]
  11. Jayaratne, M.; Premaratne, B.; Adewale, A.; Mikami, T.; Matsuba, S.; Shibayama, T.; Esteban, M.; Nistor, I. Failure mechanisms and local scour at coastal structures induced by tsunami. Coast. Eng. J. 2016, 58, 1640017. [Google Scholar] [CrossRef] [Scilit]
  12. Koshimura, S.; Hayashi, S.; Gokon, H. The impact of the 2011 Tohoku earthquake tsunami disaster and implications to the reconstruction. Soils Found. 2014, 54, 560–572. [Google Scholar] [CrossRef] [Scilit]
  13. Amakuni, K.; Terazono, N.; Yamamoto, T.; Enomoto, T. Basic analysis on building damages by tsunami due to the 2011 Great East Japan earthquake disaster using GIS. In Proceedings of the 15th World Conference on Earthquake Engineering, Lisbon, Portugal, 24–28 September 2012. [Google Scholar]
  14. Charvet, I.; Suppasri, A.; Imamura, F. Empirical fragility analysis of building damage caused by the 2011 Great East Japan tsunami in Ishinomaki City using ordinal regression, and influence of key geographical features. Stoch. Environ. Res. Risk Assess. 2014, 28, 1853–1867. [Google Scholar] [CrossRef] [Scilit]
  15. Chock, G.; Robertson, I.N. Tsunami design criteria and load cases of the ASCE 7-16 Chapter 6, tsunami loads and effects. In Proceedings of the 16th World Conference on Earthquake Engineering (16WCEE), Santiago, Chile, 9–13 January 2017. [Google Scholar]
  16. ASCE/SEI 7-16; Minimum Design Loads and Associated Criteria for Buildings and Other Structures. American Society of Civil Engineers: Reston, VA, USA, 2017.
  17. ASCE/SEI 7-22; Minimum Design Loads and Associated Criteria for Buildings and Other Structures. American Society of Civil Engineers: Reston, VA, USA, 2022.
  18. Williams, J.H.; Paulik, R.; Aránguiz, R.; Wild, A. Vulnerability of physical infrastructure network components to damage from the 2015 Illapel tsunami, Coquimbo, Chile. Pure Appl. Geophys. 2024, 181, 2421–2445. [Google Scholar] [CrossRef] [Scilit]
  19. Fraser, S.; Raby, A.; Pomonins, A.; Goda, K.; Chian, S.C.; Macabuag, J.; Offord, M.; Saito, K.; Sammonds, P. Tsunami damage to coastal defences and buildings in the March 11th 2011 Mw9.0 Great East Japan earthquake and tsunami. Bull. Earthq. Eng. 2013, 11, 205–239. [Google Scholar] [CrossRef] [Scilit]
  20. Department of Homeland Security. Guidelines for Design of Structures for Vertical Evacuation from Tsunamis, 3rd ed.; US Department of Homeland Security, Federal Emergency Management Agency: Hyattsville, MD, USA, 2008.
  21. Robertson, I.N. Recent advances in tsunami design of coastal structures. Coast. Eng. Proc. 2023, 37, 83. Available online: https://icce-ojs-tamu.tdl.org/icce/article/view/12939 (accessed on 21 May 2025). [CrossRef] [Scilit]
  22. Rajkumari, S.; Thakkar, K.; Goyal, H. Fragility analysis of structures subjected to seismic excitation: A state-of-the-art review. Structures 2022, 40, 303–316. [Google Scholar] [CrossRef] [Scilit]
  23. Rossetto, T.; De la Barra, C.; Petrone, C.; De la Llera, J.C.; Vásquez, J.; Baiguera, M. Comparative assessment of nonlinear static and dynamic methods for analysing building response under sequential earthquake and tsunami. Earthq. Eng. Struct. Dyn. 2019, 48, 867–887. [Google Scholar] [CrossRef] [Scilit]
  24. Suppasri, A.; Mas, E.; Charvet, I.; Gunasekera, R.; Imai, K.; Fukutani, Y.; Abe, Y.; Imamura, F. Building damage characteristics based on surveyed data and fragility curves of the 2011 Great East Japan tsunami. Nat. Hazards 2013, 66, 319–341. [Google Scholar] [CrossRef] [Scilit]
  25. Kihara, N.; Kaida, H.; Shibayama, A.; Miyagawa, Y. Responses of concrete vertical walls to tsunami wave pressures and debris impact. Coast. Eng. Proc. 2018, 1, 38. [Google Scholar] [CrossRef] [Scilit]
  26. Kihara, N.; Niida, Y.; Takabatake, D.; Kaida, H.; Shibayama, A.; Miyagawa, Y. Large-scale experiments on tsunami-induced pressure on a vertical tide wall. Coast. Eng. 2015, 99, 46–63. [Google Scholar] [CrossRef] [Scilit]
  27. Naito, C.J.; Riggs, H.R.; Wei, Y.; Cercone, C. Shipping-container impact assessment for tsunamis. J. Waterw. Port Coast. Ocean Eng. 2016, 142, 05016003. [Google Scholar] [CrossRef] [Scilit]
  28. Naito, C.J.; Cercone, C.; Riggs, H.R.; Cox, D. Procedure for site assessment of the potential for tsunami debris impact. J. Waterw. Port Coast. Ocean Eng. 2014, 140, 223–232. [Google Scholar] [CrossRef] [Scilit]
  29. Baiguera, M.; Rossetto, T.; Robertson, I.N.; Petrone, C. Towards a tsunami nonlinear static analysis procedure for the ASCE 7 standard. In Proceedings of the 2nd International Conference on Natural Hazards & Infrastructure 2019, Chania, Greece, 23–26 June 2019. [Google Scholar]
  30. Aegerter, D.W.; Robertson, I.N. Push-over tsunami analysis using ETABS. In Current Perspectives and New Directions in Mechanics, Modelling and Design of Structural Systems, Proceedings of the 8th International Conference on Structural Engineering, Mechanics and Computation 2022, Cape Town, South Africa, 5–7 September 2022; CRC Press/Balkema: Boca Raton, FL, USA, 2023; pp. 221–227. [Google Scholar]
  31. McKenna, F.; Fenves, G.L.; Scott, M.H.; Jeremic, B. Open System for Earthquake Engineering Simulation (OpenSees), version 3.8.0; University of California: Berkeley, CA, USA, 2000. Available online: https://opensees.berkeley.edu/ (accessed on 15 June 2024).
  32. Computers and Structures, Inc. ETABS Integrated Building Design Software, version 2018; CSI: Walnut Creek, CA, USA, 2018. Available online: https://www.csiamerica.com/products/etabs (accessed on 1 December 2024).
  33. Attary, N.; Unnikrishnan, V.U.; van de Lindt, J.W.; Cox, D.T.; Barbosa, A.R. Performance-based tsunami engineering methodology for risk assessment of structures. Eng. Struct. 2017, 141, 676–686. [Google Scholar] [CrossRef] [Scilit]
  34. Petrone, C.; Rossetto, T.; Goda, K. Fragility assessment of a RC structure under tsunami actions via nonlinear static and dynamic analyses. Eng. Struct. 2017, 136, 36–53. [Google Scholar] [CrossRef] [Scilit]
  35. Macabuag, J.; Raby, A.; Pomonis, A.; Nistor, I.; Wilkinson, S.; Rossetto, T. Tsunami design procedures for engineered buildings: A critical review. Proc. Inst. Civ. Eng. Civ. Eng. 2018, 171, 166–178. [Google Scholar] [CrossRef] [Scilit]
  36. Robertson, I.N.; Chock, G. Overview and technical background to development of ASCE 7-16 Chapter 6, Tsunami Loads and Effects. In Proceedings of the 17th World Conference on Earthquake Engineering (17WCEE), Sendai, Japan, 13–18 September 2020; p. C001103. [Google Scholar]
  37. Chock, G. Tsunami-resilient building design considerations using the ASCE 7 standard. In Proceedings of the 17th World Conference on Earthquake Engineering (17WCEE), Sendai, Japan, 13–18 September 2020; p. C000860. [Google Scholar]
  38. Baiguera, M.; Rossetto, T.; Robertson, I.N.; Petrone, C. A procedure for performing nonlinear pushover analysis for tsunami loading to ASCE 7. J. Struct. Eng. 2022, 148, 04021270. [Google Scholar] [CrossRef] [Scilit]
  39. Baiguera, M.; Aegerter, D.W.; Rossetto, T.; Robertson, I.N. Performing tsunami push-over analysis using two different modelling approaches. In Proceedings of the 18th World Conference on Earthquake Engineering (18WCEE), Milan, Italy, 30 June–5 July 2024. [Google Scholar]
  40. Koh, M.J.; Park, H.; Kim, A.S. Tsunami-driven debris hazard assessment at a coastal community: Focusing on shipping container debris hazards at Honolulu Harbor, Hawaii. Coast. Eng. 2024, 187, 104408. [Google Scholar] [CrossRef] [Scilit]
  41. Doyle, K.; Koh, M.J.; Jayasekara, J.R.; Cox, D.; Park, H.; Kameshwar, S.; Lomonaco, P. Tsunami debris damming forces and associated coefficients for elevated coastal structure columns: Experimental comparison to ASCE 7-22 minimum design loads. J. Struct. Eng. 2025, 151, 04024200. [Google Scholar] [CrossRef] [Scilit]
  42. Abdelhafeez, M.; Park, H.; Sherif, M.; Ghanem, A.; Moon, D.-S. Effects of tsunami wave and bathymetric parameters on hydrodynamic forces and structural fragility. J. Build. Eng. 2026, 118, 115077. [Google Scholar] [CrossRef] [Scilit]
  43. McGovern, D.J.; Allsop, W.; Rossetto, T.; Chandler, I. Large-scale experiments on tsunami inundation and overtopping forces at vertical sea walls. Coast. Eng. 2023, 179, 104222. [Google Scholar] [CrossRef] [Scilit]
  44. Otey, D.; Vielma, J.C.; Winckler, P. Structural failure modes of single-story timber houses under tsunami loads using ASCE 7’s energy grade line analysis. J. Mar. Sci. Eng. 2025, 13, 484. [Google Scholar] [CrossRef] [Scilit]
  45. Gacitua, J.; Montisci, A.; Pibi, F.; Porcu, M.C.; Vielma, J.C. Neural network inversion for the optimal design of earthquake-resistant steel frames. In Proceedings of the 18th World Conference on Earthquake Engineering, Milano, Italy, 30 June–5 July 2024. [Google Scholar]
  46. Seismosoft Ltd. SeismoStruct 2024 User Manual—A Computer Program for Static and Dynamic Nonlinear Analysis of Framed Structures; Seismosoft Ltd.: Pavia, Italy, 2024; Available online: https://seismosoft.com/ (accessed on 9 March 2026).
  47. Autodesk Inc. Robot Structural Analysis Professional, version 2024; Autodesk Inc.: San Francisco, CA, USA, 2024. Available online: https://www.autodesk.com/products/robot-structural-analysis/overview (accessed on 10 May 2026).
  48. ASTM A36/A36M-05; Standard Specification for Carbon Structural Steel. ASTM International: West Conshohocken, PA, USA, 2005.
  49. Chopra, A.K. Dinámica de Estructuras, 4th ed.; Pearson Educación de México: Naucalpan de Juárez, Mexico, 2014. [Google Scholar]
  50. Fauzan; Kurniawan, R.; Syahdiza, N.; Al Jauhari, Z.; Nugraha, M.D.A. Fragility curve of school building in Padang City with and without retrofitting due to earthquake and tsunami loads. Int. J. GEOMATE 2023, 24, 102–109. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.