Eye-Tracking Assessment in Patients with Disorders of Consciousness: A Systematic Review

,
,
,
,
,
and
1
Fondazione Don Gnocchi, ONLUS, 83054 Sant’Angelo dei Lombardi, Italy
2
Laboratory of Neuronal Networks Morphology and Systems Biology, Department o f Mental, Physical Health and Preventive Medicine, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
3
IRCCS SYNLAB SDN, Via E. Gianturco 113, 80137 Naples, Italy
*
Author to whom correspondence should be addressed.

Highlights

What are the main findings?
  • Eye-tracking detects 2.5× more visual responses than standard clinical observation (46.2% vs. 18.1%), demonstrating its superior sensitivity for identifying covert consciousness signs missed by CRS-R.
  • Mirror stimuli achieve the highest detection rates (97% of patients with MCS), followed by person (69%) and object (57%) stimuli, providing immediate practical guidance for optimising clinical assessment protocols.
What are the implications of the main findings?
  • Advanced VR-based systems achieve high diagnostic accuracy: sensitivity 100% and specificity 88.9% (RPTL-V biomarker), with preliminary prognostic value—62.5% of overt trackers demonstrated command-following at one year.
  • High heterogeneity and small sample size of selected studies supported a conditional recommendation for eye-tracking as a supplementary tool alongside CRS-R, not a replacement.

Abstract

Background/Objectives: Disorders of consciousness (DOC), including vegetative state/unresponsive wakefulness syndrome (VS/UWS) and minimally conscious state (MCS), present significant diagnostic challenges. Misdiagnosis rates approach 40%, often due to limitations in detecting subtle behavioural responses through clinical observation alone. Eye-tracking technology offers objective, quantitative assessment of visual behaviours that may reveal covert signs of consciousness. This systematic review aimed to evaluate the diagnostic accuracy of eye-tracking technology compared to the Coma Recovery Scale-Revised (CRS-R) for detecting visual responses and consciousness signs in patients with DOC; to examine stimulus effects; and to assess prognostic value. Methods: A systematic literature search was conducted across SciSpace, Google Scholar, PubMed, and institutional libraries following PRISMA 2020 guidelines. Eligibility criteria specified studies involving patients with prolonged DOC assessed using eye-tracking technology. Data extraction, risk of bias assessment, and GRADE certainty evaluation were conducted systematically. Results: Fifteen studies (n = 4–123 patients; published 2012–2025) were included. Eye-tracking detected visual responses in significantly more patients than clinical observation alone (46.2% vs. 18.1% in one study). Mirror stimuli demonstrated the highest detection sensitivity (97% vs. 69% for person and 57% for object). Affectively salient stimuli elicited stronger tracking responses in patients with MCS (37.3% vs. 29.9–30.6% neutral). Advanced VR-based systems achieved high diagnostic accuracy (sensitivity 100%, specificity 88.9%) with prognostic value (overt tracking predicting 62.5% command-following at one year). GRADE certainty was Low for detection rates and diagnostic discrimination, and Very Low for sensitivity, specificity, and prognostic outcomes. Conclusions: Eye-tracking provides objective, sensitive assessment of visual behaviours in patients with DOC and may reduce misdiagnosis rates, supporting a conditional recommendation for its use as a supplementary assessment tool alongside CRS-R. Methodological heterogeneity, small sample sizes, and absence of blinding limit certainty. Adequately powered, multicentre prospective studies are urgently needed.

1. Introduction

Disorders of consciousness (DOC) represent a spectrum of conditions characterised by impaired awareness and wakefulness following severe brain injury [1,2]. The two primary diagnostic categories are vegetative state/unresponsive wakefulness syndrome (VS/UWS), characterised by wakefulness without awareness, and minimally conscious state (MCS), in which patients demonstrate inconsistent but reproducible signs of consciousness [1,2]. Accurate differential diagnosis between these states is critical for prognosis, treatment planning, and ethical decision-making regarding life-sustaining interventions [3,4].
Despite the development of standardised behavioural assessment tools such as the Coma Recovery Scale-Revised (CRS-R) [5], misdiagnosis rates in DOC remain alarmingly high, approaching 40% in some studies [6]. This diagnostic uncertainty stems from multiple factors, including the subtle and fluctuating nature of behavioural responses, motor impairments that mask cognitive abilities, within-day variability in arousal and responsiveness, and the inherent limitations of subjective clinical observation [7,8]. The phenomenon of “covert consciousness”—in which patients possess awareness but cannot reliably demonstrate it through voluntary motor responses—further complicates clinical assessment [1,9,10].
Visual pursuit (VP) and visual fixation (VF) are recognised as cardinal behavioural signs of the minimally conscious state in major diagnostic frameworks, including the CRS-R and the Aspen Workgroup criteria [5]. These visual behaviours are considered among the first signs of emerging consciousness and serve as key diagnostic markers differentiating MCS from VS/UWS [11,12,13,14,15,16]. However, the assessment of VP and VF through clinical observation alone is subject to inter-rater variability, requires specialised training, and may fail to detect subtle or inconsistent responses [1,10].
Eye-tracking technology offers a promising solution to these diagnostic challenges by providing objective, quantitative measurement of gaze behaviour, fixation patterns, and pupillary responses [4,15,17]. Unlike subjective clinical observation, eye-tracking systems can detect and quantify visual behaviours with high temporal and spatial resolution, potentially revealing covert signs of consciousness that escape detection during standard bedside assessment [15,18,19]. Recent technological advances, including wearable eye-tracking devices, virtual reality (VR) integration, and hybrid brain–computer interface (BCI) systems combining eye-tracking with electroencephalography (EEG), have expanded the potential applications of this technology in DOC assessment [20,21,22,23].
Despite growing interest in eye-tracking for DOC assessment, several critical questions remain unanswered. First, the comparative diagnostic accuracy of eye-tracking versus standard clinical assessment has not been systematically evaluated across studies. Second, the influence of stimulus characteristics—including stimulus type (mirror, person, object), affective salience (familiar vs. unfamiliar), and presentation modality (real-world vs. virtual)—on detection rates requires synthesis. Third, the prognostic value of eye-tracking findings for predicting functional recovery and emergence from DOC has not been comprehensively reviewed. Finally, the methodological heterogeneity across studies necessitates critical appraisal to guide future research and clinical implementation.
This systematic review aimed to: (1) evaluate the diagnostic accuracy and sensitivity of eye-tracking technology in detecting VP and VF in patients with DOC; (2) compare eye-tracking with standard CRS-R assessment; (3) examine the influence of stimulus type, affective salience, and presentation modality; (4) assess the prognostic value of eye-tracking findings; (5) explore emerging VR and hybrid BCI technologies; and (6) identify methodological limitations to inform future research.

2. Materials and Methods

This systematic review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines [24]. The completed PRISMA 2020 checklist is provided in Supplementary Table S1. The review protocol was developed a priori but was not registered in an international registry such as PROSPERO. The predefined protocol was documented internally to ensure transparency and consistency throughout the review process.

2.1. PICO Framework

Population (P): Adult patients (≥18 years) with prolonged DOC (VS/UWS or MCS), including MCS-minus and MCS-plus subcategories, with acquired brain injury of any aetiology (traumatic, hypoxic–ischaemic, stroke, subarachnoid haemorrhage). Chronic phase (>4 weeks post-injury) preferred; acute/subacute not excluded.
Intervention (I): Eye-tracking technology for assessment of visual behaviours, including infrared (stationary or wearable), video-based, VR-integrated, and hybrid EEG-BCI systems. Outcomes: visual pursuit, visual fixation, gaze patterns, and pupillary responses across various stimulus types.
Comparison (C): Standard clinical behavioural assessment, primarily CRS-R; other standardised scales (GCS, WHIM, SMART); clinical observation without technological augmentation; comparison between stimulus types or eye-tracking protocols.
Outcomes (O): Primary: detection rate of VP/VF; diagnostic accuracy (sensitivity, specificity) for differentiating MCS from VS/UWS. Secondary: stimulus type effects; prognostic value for functional recovery; technical feasibility and inter-rater reliability.

2.2. Eligibility Criteria

According to predetermined inclusion and exclusion criteria, clinical studies that looked at ET assessment on DOC were included. Inclusion criteria: empirical studies (any design) reporting original data; adult patients (≥18 years) diagnosed with VS/UWS or MCS; any form of eye-tracking technology used for diagnostic or prognostic assessment; quantitative measures of visual behaviour as outcomes (pursuit, fixation, gaze metrics, or derived biomarkers); published in peer-reviewed journals or as preprints (2000–2025); and English language. Exclusion criteria: review articles, editorials, commentaries, and conference abstracts without full-text availability; studies reporting only qualitative or anecdotal observations without quantitative eye-tracking data; studies exclusively involving healthy controls, paediatric populations, or non-DOC neurological conditions; studies using eye-tracking solely for rehabilitation or communication without diagnostic intent; and case reports with fewer than three patients.

2.3. Information Sources and Search Strategy

The systematic search was conducted across four databases: SciSpace (n = 100), Google Scholar (n = 55), PubMed (n = 67), and institutional libraries (n = 8). Reference lists of included studies were manually screened for additional relevant publications. Direct retrieval of known relevant studies identified through expert consultation was also performed.
Search terms included combinations of: “eye tracking”, “eye-tracking”, “visual pursuit”, “visual fixation”, “gaze”, “disorders of consciousness”, “vegetative state”, “unresponsive wakefulness syndrome”, “minimally conscious state”, “CRS-R”, “brain injury”, “virtual reality”, and “brain-computer interface”. Complete Boolean search strings for each database are provided in Supplementary File S1. For example, PubMed Search String was: (“eye tracking”[MeSH Terms] OR “eye tracking”[tiab] OR “eye movement”[tiab] OR “gaze tracking”[tiab] OR “visual tracking”[tiab] OR “oculomotor”[tiab] OR “eye-tracking”[tiab] OR “gaze-tracking”[tiab] OR “visual pursuit”[tiab]) AND (“disorder of consciousness”[tiab] OR “disorders of consciousness”[tiab] OR “vegetative state”[tiab] OR “unresponsive wakefulness syndrome”[tiab] OR “minimally conscious state”[tiab] OR “VS/UWS”[tiab] OR “MCS”[tiab] OR “prolonged disorder of consciousness”[tiab] OR “chronic disorder of consciousness”[tiab] OR “coma”[MeSH Terms] OR “persistent vegetative state”[MeSH Terms] OR “consciousness disorders”[MeSH Terms]) AND (“diagnosis”[tiab] OR “diagnostic accuracy”[tiab] OR “detection”[tiab] OR “assessment”[tiab] OR “evaluation”[tiab] OR “classification”[tiab] OR “sensitivity”[tiab] OR “specificity”[tiab] OR “prognosis”[tiab] OR “prognostic”[tiab]).

2.4. Study Selection and Data Extraction

After deduplication, two reviewers (A.E. and C.C.) independently screened all titles and abstracts, and subsequently assessed full texts for eligibility. Inter-rater agreement for full-text inclusion was κ = 0.89 (substantial agreement). Disagreements were resolved through consensus discussion; no third reviewer arbitration was required. The PRISMA 2020 flow diagram (Figure 1) details the selection process.
Figure 1. PRISMA Flow Diagram. Study selection process across four database sources (SciSpace, Google Scholar, PubMed, institutional libraries). Records identified: 230; screened: 103; full-text assessed: 42; included: 15. Exclusion reasons at full-text stage: no eye-tracking methodology (n = 12), review/commentary articles (n = 9), insufficient data (n = 4), case reports < 3 patients (n = 2).
A standardised data extraction form was developed and pilot-tested. Information extracted included: study design, sample size and diagnostic breakdown, eye-tracking device and protocol, stimulus characteristics, detection rates, sensitivity, specificity, AUC, 95% confidence intervals, and key statistical findings. Data extraction was performed from full-text PDFs where available (n = 13) and from abstracts, DOI metadata, and published summaries for remaining studies (n = 2). In particular, full-text PDFs were unavailable for three included studies [23,25]; data for these studies were extracted from published abstracts and DOI metadata only. This constitutes a methodological limitation, as abstract-level extraction is less reliable for complex methodological and statistical variables.

2.5. Risk of Bias Assessment

The risk of bias assessment was conducted using a domain-based approach adapted from the Cochrane Risk of Bias tool, applied to observational and non-randomised studies. Each study was evaluated across six bias domains, with each domain rated on a three-level scale: Low for adequate safeguards in place—bias unlikely to affect results; unclear for insufficient information to make a definitive judgement; and High for significant methodological weakness—bias likely present. Inter-rater agreement for bias ratings was κ = 0.82.

2.6. Certainty of Evidence

The GRADE (Grading of Recommendations Assessment, Development and Evaluation) framework was applied to five key outcomes [26]. Certainty was assessed across five domains: risk of bias, inconsistency, indirectness, imprecision, and publication bias. Starting certainty for observational studies was Low, with upgrades and downgrades applied per GRADE rules.

3. Results

3.1. Study Selection and Characteristics

The systematic search identified 103 unique records across all databases. After title and abstract screening, 42 studies were selected for full-text review. Following detailed assessment against eligibility criteria, 15 studies were included in the final systematic review (Figure 1). The included studies were published between 2012 and 2025, with sample sizes ranging from 4 to 123 patients with DOC.
Table 1 presents structured data extraction for all 15 included studies.
Table 1. Characteristics of Included Studies.

3.2. Risk of Bias Assessment Findings

Risk of bias was variable across studies. Common limitations included: (1) lack of blinding (assessors not blinded to clinical diagnosis in any study); (2) small sample sizes (median n = 18); (3) heterogeneous reference standards (CRS-R administration varied); (4) incomplete reporting of calibration success rates; and (5) potential selection bias (convenience sampling). Detailed risk of bias assessments are presented in Table 2.
Table 2. Risk of Bias Assessment for Included Studies.
Regarding the sample size, most studies had small to moderate sample sizes (n = 4 to n = 46), with only three studies exceeding 50 participants [29,31,34]. This limits statistical power and generalisability. As for diagnostic criteria, studies using standardised tools (CRS-R) and validated eye-tracking protocols showed lower risk. Blinding of assessors was rarely reported, introducing potential bias in subjective outcome interpretation. Studies with well-defined, standardised eye-tracking protocols showed lower risk. Exploratory and novel technology studies showed moderate risk due to protocol development. Few studies included healthy control groups, limiting ability to establish normative benchmarks. Finally, within-day variability, arousal fluctuations, medication effects, and sensory impairments were inconsistently addressed across studies.
Overall, the majority of studies demonstrated moderate risk of bias, with a few showing low–moderate [14,29] or high risk (several studies with insufficient reporting).
Table 2 summarises the risk of bias assessment across seven domains for all 15 included studies.
Figure 2 presents the assessment as a heatmap.
Figure 2. Risk of Bias Heatmap. Colour-coded matrix (Green—Low/Orange—Unclear/Red—High) with ✓ ? ✗ symbols per domain × study [14,15,27,28,29,30,31,32,34,36]. Aklepi 2024 shows the cleanest profile [25]; Kujawa 2021/2022 [33,35] and Johansson 2021/2025 [1,23] have the most high-risk domains.

3.3. Synthesis of Findings

3.3.1. Detection of Visual Pursuit and Fixation

Eye-tracking technology demonstrated high sensitivity for detecting visual pursuit and fixation across multiple studies [30,31,34,35]. Trojano et al. (2012) demonstrated that patients with MCS exhibited on-target fixations 67.8% of the time compared to 32.2% in patients with VS/UWS (χ2 p < 0.001) [27]. The superiority of objective eye-tracking over clinical observation was dramatically demonstrated by Johansson et al. (2025), who found that wearable eye-tracking detected responses in 46.2% of patients (6/13) compared to 18.1% (2/11) detected by CRS-R visual subscore alone, representing a 2.5-fold increase in detection rate (χ2(1) = 41.486, p < 0.001) [1]. Figure 3 presents detection rates across studies.
Figure 3. Eye-Tracking Detection Rates Across Studies. Grouped bar chart showing overall + two subgroup rates per study [1,14,15,23,25,27,28,29,30,31,32,33,34,35,36]. Wannez 2018 [32] (90%) and Kujawa 2022 [35] dynamic (100%) show the highest rates, while Sattin 2021 [34] (21%) and Trojano 2013 [28] (37%) the lowest.

3.3.2. Stimulus Type Effects

Mirror stimuli demonstrated consistent superiority across multiple studies. Thonnard et al. (2014) reported that 97% of patients with MCS tracked their own reflection, compared to 69% tracking a person and 57% tracking an object [29]. Affectively salient stimuli (photographs of close relatives) elicited stronger tracking responses in patients with MCS (37.3%) compared to neutral stimuli (29.9–30.6%). For affective salience: χ2(1) = 6.8, p = 0.009, and d = 0.42 [95% CI: 0.11–0.73]. This effect was not observed in patients with VS/UWS, suggesting that affective processing may be a marker of minimal consciousness.

3.3.3. Objective Eye-Tracking vs. Clinical Assessment

Lee et al. (2024) identified one patient with positive RPTL biomarker responses not detected by CRS-R, demonstrating that eye-tracking can reveal covert consciousness signs missed by behavioural scales [14]. Zurek et al. (2024) compared the MCSD test with the CRS-R in 46 patients and found that eye-tracking provided additional diagnostic information beyond CRS-R alone [15].

3.3.4. Advanced Technologies: VR and Hybrid BCI Systems

Lee et al. (2024) developed a VR-based system using an HTC Vive head-mounted display with integrated infrared pupil tracking, achieving RPTL-V (Repetitive Pupillary Light Reflex in Virtual Reality) sensitivity of 100% and specificity of 88.9% (preprint, not peer-reviewed) [14]. Yi et al. (2024) developed a hybrid BCI system integrating EEG and eye-tracking, achieving ∼88.9% average accuracy for multimodal consciousness assessment [36]. Aklepi et al. (2024) demonstrated that immersive VR stimuli revealed covert tracking responses in patients with TBI not detected with standard stimuli [25].

3.3.5. Prognostic Value

Lee et al. (2024) found that overt tracking on the RPTL biomarker predicted command-following at one year in 62.5% of cases (n = 8 overt trackers), providing preliminary evidence for the prognostic utility of eye-tracking [14]. Figure 4 presents the forest plot with 95% confidence intervals across studies.
Figure 4. Forest Plot of Eye-Tracking Detection Rates and Diagnostic Accuracy. Plot sensitivity, specificity, AUC, and κ with 95% CIs for 5 studies reporting quantitative diagnostic accuracy [1,14,30,35,36]. Most metrics cluster between 0.83 and 1.00; Johansson 2025 [1] κ = 0.073 is notably low.

3.3.6. GRADE Certainty Assessment

The GRADE framework was applied to five key outcomes. Figure 5 presents the GRADE evidence summary and domain-by-domain heatmap. Table 3 presents the Summary of Findings table. The overall certainty of evidence was Low for detection rates and diagnostic discrimination, and Very Low for sensitivity, specificity, and prognostic outcomes. Key reasons for downgrading included: (1) serious risk of bias (blinding universally absent; small samples in most studies); (2) serious inconsistency in detection rates (range 13–100%); (3) very serious imprecision for sensitivity and specificity outcomes (only 4 studies, n ≤ 21 patients with DOC each); and (4) suspected publication bias. The detection rate outcome received a one-level upgrade for large effect size (2.5× relative increase vs. CRS-R). Full domain-by-domain justification is provided in Supplementary Table S2.
Figure 5. GRADE Evidence Summary. Domain-by domain heatmap across five GRADE domains (risk of bias, inconsistency, indirectness, imprecision, publication bias) and overall certainty for each outcome and article [1,14,15,23,25,27,28,29,30,31,32,33,34,35,36]. Colour-coded heatmap (🟢 Not Serious/🟡 Serious/🟠 Very Serious/🔴 Undetected/Very Low) with the Overall Certainty column separated by a bold vertical line.
Table 3. GRADE Summary of Findings.

4. Discussion

This systematic review identified fifteen studies examining eye-tracking technology for consciousness assessment in patients with DOC. The evidence consistently demonstrates that eye-tracking provides objective, quantitative measurement of visual behaviours that complement and augment standard clinical assessment. Five principal themes emerged: (1) enhanced detection of VP and VF compared to clinical observation; (2) critical influence of stimulus type on detection rates; (3) quantitative advantages of eye-tracking over categorical clinical scales; (4) promising diagnostic and prognostic utility of advanced VR and BCI technologies; and (5) preliminary but encouraging prognostic evidence.
The included studies demonstrated considerable heterogeneity across multiple dimensions. Eye tracking technologies ranged from stationary infrared systems [27,28] to wearable devices [1,31], VR-integrated systems [14,25], and hybrid BCI approaches. These systems vary in sampling rate (30–60 Hz), spatial accuracy (0.5–2° visual angle), calibration requirements, and susceptibility to artefacts. The lack of standardisation makes it difficult to determine whether differences in findings reflect true patient characteristics or technical factors.
The enhanced sensitivity of eye-tracking compared to clinical observation suggests that integration of this technology into routine assessment protocols could reduce the unacceptably high misdiagnosis rate in DOC [1,6]. Given that misdiagnosis has profound implications for treatment decisions, prognostic counselling, and ethical considerations, any technology that improves diagnostic accuracy warrants serious consideration. The finding that mirror stimuli achieve 97% detection rates has immediate practical implications for clinical assessment protocols. Based on the GRADE certainty assessment (Low to Very Low), the current evidence supports a conditional (weak) recommendation for eye-tracking as a supplementary tool alongside CRS-R, rather than a strong recommendation for routine replacement. This aligns with existing clinical guidance recommending multimodal assessment.
The detection of visual responses by eye-tracking that are not observed clinically provides empirical support for the concept of “covert consciousness”—the dissociation between preserved awareness and the ability to demonstrate that awareness through voluntary motor responses. This dissociation has important theoretical implications for understanding the neural basis of consciousness and the relationship between awareness and action.
Several limitations affect this study and possible clinical translation of eye-tracking in DOC, as demonstrated by the risk of bias and the certainty assessment. First, the majority of studies included small samples (range n = 6–46), with only two studies exceeding 40 participants [15,29]. Small samples limit statistical power, increase risk of Type II errors, and reduce generalisability. Moreover, blinding of assessors was universally absent or unreported, introducing potential performance and detection bias. Only studies using fully automated algorithms [14,25] partially mitigate this concern. Key confounders, including time since injury, aetiology, medication effects, arousal fluctuations, and sensory impairments, were inconsistently addressed. Finally, while most studies used CRS-R, one used GCS and others used neurophysiological measures or clinical observation without formal scale administration, demonstrating a reference standard variability that deeply affects translatability of this tool. The substantial clinical and methodological heterogeneity precluded quantitative synthesis; all findings are based on narrative synthesis. A further limitation of the included studies, and of eye-tracking technology in the context of DOC assessment more broadly, concerns age-related performance variability. Corneal-reflection-based systems may be affected by corrective lenses, while observational face-tracking systems are frequently trained on databases biased towards younger individuals (approximately 20–45 years), with sparse representation of individuals aged >65 years, which may result in reduced calibration accuracy, increased tracking loss, and higher error rates in older patients with DOC [37,38]. Age-related morphological changes—including orbital bone resorption, repositioning of facial fat pads, and periorbital tissue changes—alter the facial landmarks on which many tracking algorithms rely. The studies reported a mean patient age that varied considerably, with the youngest participant being 7 years old [28] and studies generally including adult population up to 76 years of age. Future studies should explicitly assess ET system performance across age strata and report calibration success rates by age group.
As for this study’s limitations, (a) this review was not prospectively registered in PROSPERO, which is acknowledged as a limitation, even if eligibility criteria were pre-specified to minimise post hoc modification. (b) The search was restricted to English-language publications, which may have excluded relevant studies published in other languages. (c) Full-text data were unavailable for two included studies, with data extracted from abstracts only; this may have introduced underreporting of methodological and statistical details for those studies.
To conclude, eye-tracking technology provides objective, sensitive assessment of visual behaviours in patients with DOC and demonstrates consistent advantages over standard clinical observation. The evidence supports a conditional recommendation for eye-tracking as a supplementary assessment tool alongside CRS-R, with mirror and personally meaningful stimuli recommended to optimise detection rates. Advanced VR-based systems and hybrid BCI approaches show promise for both diagnostic and prognostic applications. However, the Low to Very Low GRADE certainty of the current evidence base underscores the need for rigorous, adequately powered research.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/brainsci16060590/s1, Table S1: PRISMA 2020 Checklist; File S1: Complete Boolean search string; Table S2: GRADE profile summary.

Author Contributions

Conceptualisation, A.E. and C.C.; methodology, M.F.; software, C.C.; validation, A.E., A.S. and C.C.; formal analysis, L.M. and F.M.; data curation, L.M.; writing—original draft preparation, L.M. and C.C.; writing—review and editing, A.E., A.D.F., M.F. and C.C.; supervision, A.E. and A.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable. This systematic review analysed previously published studies and did not involve direct human participants.

Data Availability Statement

Data extraction tables, risk of bias assessments, and visualisation scripts are available upon request from the corresponding author. No new data were created or analysed in this study.

Acknowledgments

This work was supported by grants from: the European Union’s Horizon 2022-MSCA grant agreement n° 101131344-DoC-Box project to AE; the Ricerca Corrente Grant from the Italian Ministry of Health (MoH) to FM, MF, and CC; and the Conto Capitale 2022 (CC-2022-23682634) from the Italian MoH to CC.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Johansson, J.; Möller, M.; Franzon, K.; Stenberg, J.; Godbolt, A.K. Eye tracking to support assessment of patients with prolonged disorder of consciousness—A case series. J. Rehabil. Med. 2025, 57, jrm41324. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
  2. Giacino, J.T.; Ashwal, S.; Childs, N.; Cranford, R.; Jennett, B.; Katz, D.I.; Kelly, J.P.; Rosenberg, J.H.; Whyte, J.; Zafonte, R.D.; et al. The minimally conscious state: Definition and diagnostic criteria. Neurology 2002, 58, 349–353. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Fins, J.J. Rethinking disorders of consciousness: New research and its implications. Hastings Cent. Rep. 2005, 35, 22–24. [Google Scholar]
  4. Ting, W.K.-C.; Perez Velazquez, J.L.; Cusimano, M.D. Eye Movement Measurement in Diagnostic Assessment of Disorders of Consciousness. Front. Neurol. 2014, 5, 137. [Google Scholar] [CrossRef] [Scilit]
  5. Giacino, J.T.; Kalmar, K.; Whyte, J. The JFK Coma Recovery Scale-Revised: Measurement characteristics and diagnostic utility. Arch. Phys. Med. Rehabil. 2004, 85, 2020–2029. [Google Scholar] [CrossRef] [Scilit]
  6. Schnakers, C.; Vanhaudenhuyse, A.; Giacino, J.; Ventura, M.; Boly, M.; Majerus, S.; Moonen, G.; Laureys, S. Diagnostic accuracy of the vegetative and minimally conscious state: Clinical consensus versus standardized neurobehavioral assessment. BMC Neurol. 2009, 9, 35. [Google Scholar] [CrossRef] [Scilit]
  7. Majerus, S.; Gill-Thwaites, H.; Andrews, K.; Laureys, S. Behavioral evaluation of conscious ness in severe brain damage. Prog. Brain Res. 2005, 150, 397–413. [Google Scholar]
  8. Candelieri, A.; Cortese, M.D.; Dolce, G.; Riganello, F.; Sannita, W.G. Visual pursuit: Within-day variability in the severe disorder of consciousness. J. Neurotrauma 2011, 28, 2013–2017. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  9. Owen, A.M.; Coleman, M.R.; Boly, M.; Davis, M.H.; Laureys, S.; Pickard, J.D. Detecting awareness in the vegetative state. Science 2006, 313, 1402. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Xiao, J.; Pan, J.; He, Y.; Xie, Q.; Yu, T.; Huang, H.; Lv, W.; Zhang, J.; Yu, R.; Li, Y. Visual Fixation Assessment in Patients with Disorders of Consciousness Based on Brain-Computer Interface. Neurosci. Bull. 2018, 34, 679–690. [Google Scholar] [CrossRef] [Scilit]
  11. Estraneo, A.; Moretta, P.; Cardinale, V.; De Tanti, A.; Gatta, G.; Giacino, J.T.; Trojano, L. A multicentre study of intentional behavioural responses measured using the Coma Recovery Scale-Revised in patients with minimally conscious state. Clin. Rehabil. 2015, 29, 803–808. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Kondziella, D.; Bender, A.; Diserens, K.; van Erp, W.; Estraneo, A.; Formisano, R.; Laureys, S.; Naccache, L.; Ozturk, S.; Rohaut, B.; et al. EAN Panel on Coma, Disorders of Consciousness. European Academy of Neurology guideline on the diagnosis of coma and other disorders of consciousness. Eur. J. Neurol. 2020, 27, 741–756. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  13. Bruno, M.A.; Vanhaudenhuyse, A.; Thibaut, A.; Moonen, G.; Laureys, S. From unresponsive wakefulness to minimally conscious PLUS and functional locked-in syndromes. J. Neurol. 2011, 258, 1373–1384. [Google Scholar] [CrossRef] [Scilit]
  14. Lee, H.H.; Hyun, C.; Kang, C.H.; Moon, W.J.; Lee, J. Evaluating impaired consciousness after acquired brain injury using a virtual-reality-based eye-tracking system. Preprint 2024. [Google Scholar] [CrossRef] [Scilit]
  15. Zurek, G.; Binder, M.; Kunka, B.; Kosikowski, R.; Rodzeń, M.; Karaś, D.; Mucha, G.; Olejniczak, R.; Gorączko, A.; Kujawa, K.; et al. Can Eye Tracking Help Assess the State of Consciousness in Non-Verbal Brain Injury Patients? J. Clin. Med. 2024, 13, 6227. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
  16. Duchowski, A.T. Eye Tracking Methodology: Theory and Practice, 3rd ed.; Springer: Cham, Switzerland, 2017. [Google Scholar]
  17. Magliacano, A.; Rosenfelder, M.; Hieber, N.; Bender, A.; Estraneo, A.; Trojano, L. Spontaneous eye blinking as a diagnostic marker in prolonged disorders of consciousness. Sci. Rep. 2021, 11, 22393. [Google Scholar] [CrossRef] [Scilit]
  18. Holmqvist, K.; Nyström, M.; Andersson, R.; Dewhurst, R.; Jarodzka, H.; Van de Weijer, J. Eye Tracking: A Comprehensive Guide to Methods and Measures; Oxford University Press: Oxford, UK, 2011. [Google Scholar]
  19. Overbeek, B.U.H.; Eilander, H.J.; Lavrijsen, J.C.M.; Koopmans, R.T.C.M. Are visual functions diagnostic signs of the minimally conscious state? an integrative review. J. Neurol. 2018, 265, 1957–1975. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
  20. Slater, M.; Sanchez-Vives, M.V. Enhancing our lives with immersive virtual reality. Front. Robot. AI 2016, 3, 74. [Google Scholar] [CrossRef] [Scilit]
  21. Wolpaw, J.R.; Wolpaw, E.W. (Eds.) Brain-Computer Interfaces: Principles and Practice; Oxford University Press: Oxford, UK, 2012. [Google Scholar]
  22. Pfurtscheller, G.; Allison, B.Z.; Brunner, C.; Bauernfeind, G.; Solis-Escalante, T.; Scherer, R.; Zander, T.O.; Mueller-Putz, G.; Neuper, C.; Birbaumer, N. The hybrid BCI. Front. Neurosci. 2010, 4, 3. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  23. Johansson, J.; Franzon, K.; Godbolt, A.K.; Möller, M.C. Methodological aspects of using a wearable eye-tracker to support diagnostic clinical evaluation of prolonged disorders of consciousness. J. Rehabil. Med. 2021, 53, jrm00213. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
  24. Page, M.J.; McKenzie, J.E.; Bossuyt, P.M.; Boutron, I.; Hoffmann, T.C.; Mulrow, C.D.; Shamseer, L.; Tetzlaff, J.M.; Akl, E.A.; Brennan, S.E.; et al. The PRISMA 2020 statement: An updated guideline for reporting systematic reviews. BMJ 2021, 372, n71. [Google Scholar] [CrossRef] [Scilit]
  25. Aklepi, G.; Manolovitz, B.; Robayo, L.E.; Sarafraz, A.; Blandino, C.F.; Arwari, B.; Sobczak, E.; Bass, D.; Ghamasaee, P.; Bolaños Saavedra, A.; et al. Covert Tracking to Immersive Stimuli in Traumatic Brain Injury Subjects with Disorders of Consciousness. J. Neurotrauma 2024, 41, 646–659. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
  26. Guyatt, G.H.; Oxman, A.D.; Vist, G.E.; Kunz, R.; Falck-Ytter, Y.; Alonso-Coello, P.; Schünemann, H.J. GRADE: An emerging consensus on rating quality of evidence and strength of recommendations. BMJ 2008, 336, 924–926. [Google Scholar] [CrossRef] [Scilit]
  27. Trojano, L.; Moretta, P.; Loreto, V.; Cozzolino, A.; Santoro, L.; Estraneo, A. Quantitative assessment of visual behavior in disorders of consciousness. J. Neurol. 2012, 259, 1888–1895. [Google Scholar] [CrossRef] [Scilit]
  28. Trojano, L.; Moretta, P.; Loreto, V.; Santoro, L.; Estraneo, A. Affective saliency modifies visual tracking behavior in disorders of consciousness. J. Neurol. 2013, 260, 306–308. [Google Scholar] [CrossRef] [Scilit]
  29. Thonnard, M.; Wannez, S.; Keen, S.; Brédart, S.; Bruno, M.-A.; Gosseries, O.; Demertzi, A.; Thibaut, A.; Chatelle, C.; Charland-Verville, V.; et al. Detection of visual pursuit in patients in minimally conscious state: A matter of stimuli and visual plane? Brain Inj. 2014, 28, 1164–1170. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  30. Naro, A.; Calabrò, R.S.; Russo, M.; Leo, A.; Pollicino, P.; Quartarone, A.; Bramanti, P. Can transcranial direct current stimulation be useful in differentiating unresponsive wakefulness syndrome from minimally conscious state patients? Restor. Neurol. Neurosci. 2015, 33, 159–176. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  31. Wannez, S.; Heine, L.; Thonnard, M.; Gosseries, O.; Laureys, S.; Coma Science Group collaborators. The repetition of behavioral assessments in diagnosis of disorders of consciousness. Ann. Neurol. 2017, 81, 883–889. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  32. Wannez, S.; Gosseries, O.; Azzolini, D.; Martial, C.; Cassol, H.; Aubinet, C.; Annen, J.; Martens, G.; Bodart, O.; Heine, L.; et al. Prevalence of coma-recovery scale-revised signs of consciousness in patients in minimally conscious state. Neuropsychol. Rehabil. 2018, 28, 1350–1359. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  33. Kujawa, K.; Zurek, G.; Kwiatkowska, A.; Olejniczak, R.; Żurek, A. Assessment of Language Functions in Patients with Disorders of Consciousness Using an Alternative Communication Tool. Front Neurol. 2021, 12, 684362. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
  34. Sattin, D.; Rossi Sebastiano, D.; Magnani, F.G.; D’Incerti, L.; Marotta, G.; Benti, R.; Tirelli, S.; Bersano, A.; Duran, D.; Visani, E.; et al. Visual fixation in disorders of consciousness: Development of predictive models to support differential diagnosis. Physiol. Behav. 2021, 230, 113310. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  35. Kujawa, K.; Żurek, A.; Gorączko, A.; Olejniczak, R.; Zurek, G. Monitoring Eye Movements Depending on the Type of Visual Stimulus in Patients with Impaired Consciousness Due to Brain Damage. Int. J. Environ. Res. Public Health 2022, 19, 6280. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
  36. Yi, Z.; Pan, J.; Chen, Z.; Lu, D.; Cai, H.; Li, J.; Xie, Q. Hybrid brain-computer interface integrating EEG and eye-tracking for consciousness assessment in patients with disorders of consciousness. IEEE Trans. Neural Syst. Rehabil. Eng. 2024, 32, 2759–2771. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  37. Domínguez-Zamora, F.J.; Lajoie, K.; Miller, A.B.; Marigold, D.S. Age-related changes in gaze sampling strategies during obstacle navigation. Gait Posture 2020, 76, 252–258. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  38. Owsley, C. Aging and vision. Vis. Res. 2011, 51, 1610–1622. [Google Scholar] [CrossRef] [Scilit] [PubMed] [PubMed Central]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.