Editorial

Editorial on the Special Issue of Applied Sciences on the Topic of Elastography

by
Christoph F. Dietrich
1,2,* and
Jeffrey C. Bamber
3
1
Sino-German Tongji-Caritas Research Center of Ultrasound in Medicine, Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
2
Department of Internal Medicine 2, Medizinische Klinik 2, Caritas Krankenhaus Bad Mergentheim, Uhlandstraße 7, 97980 Bad Mergentheim, Germany
3
Joint Department of Physics and Cancer Research UK Imaging Centre, The Institute of Cancer Research and The Royal Marsden Hospital, Cotswold Road, Sutton, London SM2 5NG, UK
*
Author to whom correspondence should be addressed.
Appl. Sci. 2018, 8(8), 1232; https://doi.org/10.3390/app8081232
Submission received: 20 June 2018 / Accepted: 17 July 2018 / Published: 26 July 2018
(This article belongs to the Special Issue Ultrasound Elastography)
Elastography is the science of creating noninvasive images of the mechanical characteristics of tissues. The basic principles of elastography have been described some years ago and have remained unchanged since they were outlined in the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) guidelines [1,2]. The first elastography guidelines worldwide were introduced and published by EFSUMB in April 2013 [1,2], were updated in 2017 for the liver [3,4], and were followed by the Japanese Society of Ultrasound in Medicine (JSUM) [5] and the World Federation for Ultrasound in Medicine and Biology (WFUMB) guidelines on basic principles [6] and applications in various organs [7,8,9,10,11,12,13,14]. The mentioned guidelines provide an introduction to the physical principles and technology on which all forms of current commercially available ultrasound elastography are based. The practical advantages and disadvantages that are associated with each of the techniques are described, and guidance is provided on the optimisation of scanning technique, image display, image interpretation, and some of the known image artefacts. The EFSUMB and the WFUMB guideline articles can be freely downloaded from the EFSUMB website (www.efsumb.org) [15] and the WFUMB website (www.wfumb.org).
As described in [1], ultrasound elastography uses ultrasonic echoes to observe tissue displacement as a function of time and space after applying a force that is either dynamic (e.g., by thumping or vibrating) or varying it so slowly that it is considered “quasi-static” (e.g., by probe palpation). The commercially available technologies can be classified according to whether this tissue displacement is (a) displayed directly as the imaged quantity, as in the method that is known as acoustic radiation force impulse (ARFI) imaging; (b) used to calculate and display strain, producing what is termed strain elastography (SE); or (c) used to calculate and display an image of shear wave speed. The last of these is an image that is, in principle, quantitative for a tissue property and is the only one that requires the creation of a shear wave, which in turn requires the use of a dynamic force. The others may use a dynamic force but can also work with a static or nearly static force [1]. However, even the measurement of shear wave speed is dependent on system parameters such as the applied shear force and the frequency of the shear wave. Elastography may be considered as a type of remote palpation that allows the measurement and display of biomechanical properties that are associated with the elastic restoring forces in the tissue that act against shear deformation. This view unifies the different types of elastography, namely SE, ARFI imaging, and SWE, and explains why they all display images with contrast for the same underlying information, which is associated with the shear elastic modulus.
A variety of methods that measure shear wave speed should be grouped under the term shear wave elastography (SWE). These include systems that calculate either the regional values of shear wave speed (without making images) using methods referred to as transient elastography (TE, including vibration-controlled transient elastography, VCTE) and point shear-wave elastography (pSWE), or images of shear wave speed using methods referred to as 2D (or 3D) shear-wave elastography (SWE). The type of elastography that is most suited to the assessment of diffuse liver disease is SWE, which measures the speed of a shear wave in the liver. In the 2017 update of the European guidelines [3,4], VCTE is regarded as a type of SWE, although it differs from other SWE methods because it uses a body-surface vibration to create a shear wave which then travels to the liver, whereas the other methods use acoustic radiation force to create the shear wave within the liver. Recently, normal values of quantities that were measured by SWE of the liver have been summarized [16] and the official American Gastroenterological Association Institute (AGAI) Guidelines on the Role of Elastography in the Evaluation of Liver Fibrosis have been published [17]. Unfortunately, despite the title of the AGAI guidelines paper, it focuses only on the role of VCTE in the evaluation of liver fibrosis, ignoring the fact that the term elastography covers all of the technologies mentioned above. This approach might indicate to the reader that elastography equates only to one commercially available equipment, the Fibroscan®, manufactured only by Echosens, which implements VCTE. This is not true. The review also classifies VCTE as an imaging-based fibrosis assessment, which it is not. VCTE as implemented on the Fibroscan® does not display an anatomical image, although, interestingly, General Electric has recently announced that the Echosens technology has been integrated into its conventional ultrasound system.
Guidelines were introduced in part because of the extremely rapid spread of the use of elastography systems in the clinic once the technology had become commercially available. It is worth mentioning that new methods can be clinically valid and yet are not always (or are rarely) supported by the highest ranking scientific evidence, namely by randomized trials. Often these innovations are so obviously of benefit that randomized controlled trials comparing them with older, less safe or less effective techniques could be deemed unethical.
Elastography can be applied to examine almost all organs in the human body. We refer to a variety of clinical papers with practical applications in the thyroid [9,18,19,20,21,22], pancreas [13], prostate [10,23,24], and endoscopic (endorectal) ultrasound applications [25,26,27] including the endobronchial use of elastography [28].
The current special issue of Applied Sciences deals with a wide range of elastography methods from many different points of view including open issues of the liver, thyroid, and magnetic resonance elastography (MRE), as well as applications in selected patient groups, e.g., pediatric patients.
MRE is an alternative to ultrasound elastography which has been described in a number of reviews, including [29,30,31]. The modern method was originated by the Mayo Clinic in 1995 [32] and, like ultrasound elastography, the technique has evolved with a number of technical variations. As with ultrasound elastography, MRE begins by measuring tissue displacement as a function of time and space. Variations exist both in terms of the motion encoding and displacement readout strategies [33] and with respect to algorithms that are used to reconstruct the viscoelastic properties from the measured displacements [34]. As with ultrasound elastography, considerable technical development continues to take place in a research context. One difference to ultrasound elastography is that although quasistatic MRE has long existed (based on a technique known as MR tagging [35]), and it provides cardiac strain assessment [36,37], it is dynamic methods that emerged into widespread clinical use, and 3D-SWE is the ultrasound elastography method that is the closest equivalent of most MRE. However, although acoustic radiation force has been tried as a method of generating displacement, MRE routinely employs harmonic vibrations that are generated by a relatively complex external MR-compatible mechanical device. The clinical use of MRE is less widespread than that of ultrasound elastography, which is likely to be due to a combination of factors, including the high entry-cost, the more limited regulatory approval, the relatively few manufacturers, the relative difficulty of patient set-up, the lack of system portability, and the relatively long examination time. Nevertheless, MRE offers a number of advantages over ultrasound elastography, such as the ability to make elastograms of parts of the body which ultrasound cannot reach (the brain transcranially and the lungs), as well as its intrinsic: controlled-frequency of vibration, 3D imaging, ability to image both elastic and viscous moduli, and capability to provide elastic anisotropy information (i.e., as a function of the direction of shear wave propagation). Commercial ultrasound elastography has yet to evolve some of these technical capabilities which arguably makes current MRE potentially more accurate and precise than current ultrasound elastography. This may explain why recent comparisons suggest that, although ultrasound and MR elastography both have good accuracy for identifying and staging liver fibrosis, MRE is the more accurate of the two [31,38,39,40,41]. Nevertheless, they each have technical strengths and limitations; ultrasound elastography may be unreliable in obese patients or where intercostal access is limited, and MRE quality may be poor in patients with substantial iron deposition [41].
The paper on the “Effect of HCV Core Antigen and RNA Clearance during Therapy with Direct Acting Antivirals on Hepatic Stiffness Measured with Shear Wave Elastography in Patients with Chronic Viral Hepatitis” C showed that liver stiffness significantly declined during and after successful antiviral treatment [42]. So far, liver stiffness monitoring during antiviral therapy has been mostly published using TE. Published data on patients who were treated with direct antiviral agents (DAAs) suggest that liver stiffness declines during treatment in patients with advanced fibrosis [43,44,45,46,47,48,49]. The decline in liver stiffness reflects more the reduction of inflammatory changes of the liver than it does in true fibrosis.
The paper “Interpretation US Elastography in Chronic Hepatitis B with or without Anti-HBV Therapy” concludes that 2D-SWE (regrettably referred to as ARFI) is a reliable tool for the measurement of liver fibrosis in chronic hepatitis B patients with alanine aminotransferase <5× the upper limit of normal. For those patients under anti-HBV therapy, the optimal timing for SWE analysis will be over 1 to 2.5 years of nucleos(t)ide analogue therapy [50].
The paper “Shear Wave Elastography Combining with Conventional Grey Scale Ultrasound Improves the Diagnostic Accuracy in Differentiating Benign and Malignant Thyroid Nodules” tackles the issue of the differential diagnosis of thyroid nodules. In patients with normal thyroid parenchyma, elastography can rule out malignancy with a high level of certainty if the lesion is displayed as soft. A stiff lesion can be either benign or malignant [51]. The same is true for other parenchymatous organs, e.g., the pancreas [52].
“Non-Invasive Assessment of Hepatic Fibrosis by Elastic Measurement of Liver Using Magnetic Resonance Tagging Images” is a paper that aims to overcome the disadvantage of MRE mentioned above, i.e., that it normally requires an MR-compatible mechanical vibrator which complicates patient set-up. Multiple locations covering a grid in the liver were tracked using MR tagging during liver displacement that was caused by forced exhalation. Two features were then extracted from the resulting time-varying grid patterns, bending energy and the difference between the spatial Fourier transforms of the grid from one moment to another. These features summarize the overall non-rigid deformation in the liver, both normal and shear strain. The more rigid the liver, the lower the values for both of these types of features. In preliminary testing on 17 normal and 17 abnormal liver cases (6 chronic hepatitis cases and 11 liver cirrhosis cases), with manual intervention in setting grid landmarks for tracking, only one abnormal liver was misclassified as normal by a bivariate linear classifier. Although the method does not result in a quantitative tissue property value such as an elastic modulus, its simplicity makes it worthy of further evaluation after development to improve its automated landmark setting.
The paper “Current knowledge in ultrasound based elastography of pediatric patients” reviews the current available literature on the use of SWE in children. Shear wave elastography techniques can be applied in children for the evaluation of liver fibrosis in several etiologies. However, for most pathologies, the evidence is still limited. The confounding factors are similar in adults, including the degree of inflammation and necrosis, iron and copper deposits, cholestasis, and congestions [53].

Funding

For J.C.B. and C.F.D., this research received no external funding.

Conflicts of Interest

J.C.B. declares membership of the advisory board of Supersonic Imagine and Michelson Diagnostics, and collaboration agreements with Phoenix Solutions, Zonare, iThera Medical and Delphinus. C.F.D. declares membership of the advisory board of Hitachi Medical Systems, Siemens Healthineers, Mindray and collaboration agreements with Supersonic Imagine, Olympus and GE. In addition honoraria are also reported for Bracco and Pentax.

References

  1. Bamber, J.; Cosgrove, D.; Dietrich, C.F.; Fromageau, J.; Bojunga, J.; Calliada, F.; Cantisani, V.; Correas, J.M.; D’Onofrio, M.; Drakonaki, E.E.; et al. EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 1: Basic principles and technology. Ultraschall Med. 2013, 34, 169–184. [Google Scholar] [CrossRef] [PubMed]
  2. Cosgrove, D.; Piscaglia, F.; Bamber, J.; Bojunga, J.; Correas, J.M.; Gilja, O.H.; Klauser, A.S.; Sporea, I.; Calliada, F.; Cantisani, V.; et al. EFSUMB guidelines and recommendations on the clinical use of ultrasound elastography. Part 2: Clinical applications. Ultraschall Med. 2013, 34, 238–253. [Google Scholar] [PubMed]
  3. Dietrich, C.F.; Bamber, J.; Berzigotti, A.; Bota, S.; Cantisani, V.; Castera, L.; Cosgrove, D.; Ferraioli, G.; Friedrich-Rust, M.; Gilja, O.H.; et al. EFSUMB Guidelines and Recommendations on the Clinical Use of Liver Ultrasound Elastography, Update 2017 (Long Version). Ultraschall Med. 2017, 38, e16–e47. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  4. Dietrich, C.F.; Bamber, J.; Berzigotti, A.; Bota, S.; Cantisani, V.; Castera, L.; Cosgrove, D.; Ferraioli, G.; Friedrich-Rust, M.; Gilja, O.H.; et al. EFSUMB Guidelines and Recommendations on the Clinical Use of Liver Ultrasound Elastography, Update 2017 (Short Version). Ultraschall Med. 2017, 38, 377–394. [Google Scholar] [CrossRef] [PubMed]
  5. Shiina, T. JSUM ultrasound elastography practice guidelines: Basics and terminology. J. Med. Ultrason. 2013, 40, 309–323. [Google Scholar] [CrossRef] [PubMed]
  6. Shiina, T.; Nightingale, K.R.; Palmeri, M.L.; Hall, T.J.; Bamber, J.C.; Barr, R.G.; Castera, L.; Choi, B.I.; Chou, Y.H.; Cosgrove, D.; et al. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 1: Basic principles and terminology. Ultrasound Med. Biol. 2015, 41, 1126–1147. [Google Scholar] [CrossRef] [PubMed]
  7. Barr, R.G.; Nakashima, K.; Amy, D.; Cosgrove, D.; Farrokh, A.; Schafer, F.; Bamber, J.C.; Castera, L.; Choi, B.I.; Chou, Y.H.; et al. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 2: Breast. Ultrasound Med. Biol. 2015, 41, 1148–1160. [Google Scholar] [CrossRef] [PubMed]
  8. Ferraioli, G.; Filice, C.; Castera, L.; Choi, B.I.; Sporea, I.; Wilson, S.R.; Cosgrove, D.; Dietrich, C.F.; Amy, D.; Bamber, J.C.; et al. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: Liver. Ultrasound Med. Biol. 2015, 41, 1161–1179. [Google Scholar] [CrossRef] [PubMed]
  9. Cosgrove, D.; Barr, R.; Bojunga, J.; Cantisani, V.; Chammas, M.C.; Dighe, M.; Vinayak, S.; Xu, J.M.; Dietrich, C.F. WFUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography: Part 4. Thyroid. Ultrasound Med. Biol. 2017, 43, 4–26. [Google Scholar] [CrossRef] [PubMed]
  10. Barr, R.G.; Cosgrove, D.; Brock, M.; Cantisani, V.; Correas, J.M.; Postema, A.W.; Salomon, G.; Tsutsumi, M.; Xu, H.X.; Dietrich, C.F. WFUMB guidelines and recommendations on the clinical use of ultrasound elastography: Part 5. prostate. Ultrasound Med. Biol. 2017, 43, 27–48. [Google Scholar] [CrossRef] [PubMed]
  11. Kudo, M.; Shiina, T.; Moriyasu, F.; Iijima, H.; Tateishi, R.; Yada, N.; Fujimoto, K.; Morikawa, H.; Hirooka, M.; Sumino, Y.; et al. JSUM ultrasound elastography practice guidelines: Liver. J. Med. Ultrason. 2013, 40, 325–357. [Google Scholar] [CrossRef] [PubMed]
  12. Nakashima, K.; Shiina, T.; Sakurai, M.; Enokido, K.; Endo, T.; Tsunoda, H.; Takada, E.; Umemoto, T.; Ueno, E. JSUM ultrasound elastography practice guidelines: Breast. J. Med. Ultrason. 2013, 40, 359–391. [Google Scholar] [CrossRef] [PubMed]
  13. Hirooka, Y.; Kuwahara, T.; Irisawa, A.; Itokawa, F.; Uchida, H.; Sasahira, N.; Kawada, N.; Itoh, Y.; Shiina, T. JSUM ultrasound elastography practice guidelines: Pancreas. J. Med. Ultrason. 2015, 42, 151–174. [Google Scholar] [CrossRef] [PubMed]
  14. Berzigotti, A.; Ferraioli, G.; Bota, S.; Gilja, O.H.; Dietrich, C.F. Novel ultrasound-based methods to assess liver disease: The game has just begun. Dig. Liver Dis. 2018, 50, 107–112. [Google Scholar] [CrossRef] [PubMed]
  15. Dietrich, C.F.; Rudd, L.; Saftiou, A.; Gilja, O.H. The EFSUMB website, a great source for ultrasound information and education. Med. Ultrason. 2017, 19, 102–110. [Google Scholar] [CrossRef] [PubMed]
  16. Dong, Y.; Sirli, R.; Ferraioli, G.; Sporea, I.; Chiorean, L.; Cui, X.; Fan, M.; Wang, W.P.; Gilja, O.H.; Sidhu, P.S.; et al. Shear wave elastography of the liver—Review on normal values. Z. Gastroenterol. 2017, 55, 153–166. [Google Scholar] [CrossRef] [PubMed]
  17. Lim, J.K.; Flamm, S.L.; Singh, S.; Falck-Ytter, Y.T. Clinical Guidelines Committee of the American Gastroenterological, A American Gastroenterological Association Institute Guideline on the Role of Elastography in the Evaluation of Liver Fibrosis. Gastroenterology 2017, 152, 1536–1543. [Google Scholar] [CrossRef] [PubMed]
  18. Dighe, M.; Barr, R.; Bojunga, J.; Cantisani, V.; Chammas, M.C.; Cosgrove, D.; Cui, X.W.; Dong, Y.; Fenner, F.; Radzina, M.; et al. Thyroid Ultrasound: State of the Art Part 1—Thyroid Ultrasound reporting and Diffuse Thyroid Diseases. Med. Ultrason. 2017, 19, 79–93. [Google Scholar] [CrossRef] [PubMed]
  19. Dighe, M.; Barr, R.; Bojunga, J.; Cantisani, V.; Chammas, M.C.; Cosgrove, D.; Cui, X.W.; Dong, Y.; Fenner, F.; Radzina, M.; et al. Thyroid ultrasound: State of the art. part 2—Focal thyroid lesions. Med. Ultrason. 2017, 19, 195–210. [Google Scholar] [CrossRef] [PubMed]
  20. Friedrich-Rust, M.; Vorlaender, C.; Dietrich, C.F.; Kratzer, W.; Blank, W.; Schuler, A.; Broja, N.; Cui, X.W.; Herrmann, E.; Bojunga, J. Evaluation of strain elastography for differentiation of thyroid nodules: Results of a prospective degum multicenter study. Ultraschall Med. 2016, 37, 262–270. [Google Scholar] [CrossRef] [PubMed]
  21. Cantisani, V.; Lodise, P.; Di Rocco, G.; Grazhdani, H.; Giannotti, D.; Patrizi, G.; Medvedyeva, E.; Olive, M.; Fioravanti, C.; Giacomelli, L.; et al. Diagnostic accuracy and interobserver agreement of Quasistatic Ultrasound Elastography in the diagnosis of thyroid nodules. Ultraschall Med. 2015, 36, 162–167. [Google Scholar] [CrossRef] [PubMed]
  22. Grazhdani, H.; Cantisani, V.; Lodise, P.; Di Rocco, G.; Proietto, M.C.; Fioravanti, E.; Rubini, A.; Redler, A. Prospective evaluation of acoustic radiation force impulse technology in the differentiation of thyroid nodules: Accuracy and interobserver variability assessment. J. Ultrasound 2014, 17, 13–20. [Google Scholar] [CrossRef] [PubMed]
  23. Correas, J.M.; Tissier, A.M.; Khairoune, A.; Vassiliu, V.; Mejean, A.; Helenon, O.; Memo, R.; Barr, R.G. Prostate cancer: Diagnostic performance of real-time shear-wave elastography. Radiology 2015, 275, 280–289. [Google Scholar] [CrossRef] [PubMed]
  24. Correas, J.M.; Tissier, A.M.; Khairoune, A.; Khoury, G.; Eiss, D.; Helenon, O. Ultrasound elastography of the prostate: State of the art. Diagn. Interv. Imaging 2013, 94, 551–560. [Google Scholar] [CrossRef] [PubMed]
  25. Dietrich, C.F.; Bibby, E.; Jenssen, C.; Saftoiu, A.; Iglesias-Garcia, J.; Havre, R.F. EUS elastography: How to do it? Endosc. Ultrasound 2018, 7, 20–28. [Google Scholar] [CrossRef] [PubMed]
  26. Dietrich, C.F.; Barr, R.G.; Farrokh, A.; Dighe, M.; Hocke, M.; Jenssen, C.; Dong, Y.; Saftoiu, A.; Havre, R.F. Strain Elastography—How To Do It? Ultrasound Int. Open 2017, 3, E137–E149. [Google Scholar] [CrossRef] [PubMed]
  27. Hocke, M.; Braden, B.; Jenssen, C.; Dietrich, C.F. Present status and perspectives of endosonography 2017 in gastroenterology. Korean J. Int. Med. 2018, 33, 36–63. [Google Scholar] [CrossRef] [PubMed]
  28. Dietrich, C.F.; Jenssen, C.; Herth, F.J. Endobronchial ultrasound elastography. Endosc. Ultrasound 2016, 5, 233–238. [Google Scholar] [CrossRef] [PubMed]
  29. Mariappan, Y.K.; Glaser, K.J.; Ehman, R.L. Magnetic resonance elastography: A review. Clin. Anat. 2010, 23, 497–511. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  30. Litwiller, D.V.; Mariappan, Y.K.; Ehman, R.L. Magnetic resonance elastography. Curr. Med. Imaging Rev. 2012, 8, 46–55. [Google Scholar] [CrossRef] [PubMed]
  31. Low, G.; Kruse, S.A.; Lomas, D.J. General review of magnetic resonance elastography. World J. Radiol. 2016, 8, 59–72. [Google Scholar] [CrossRef] [PubMed]
  32. Muthupillai, R.; Lomas, D.J.; Rossman, P.J.; Greenleaf, J.F.; Manduca, A.; Ehman, R.L. Magnetic resonance elastography by direct visualization of propagating acoustic strain waves. Science 1995, 269, 1854–1857. [Google Scholar] [CrossRef] [PubMed]
  33. Guenthner, C.; Kozerke, S. Encoding and readout strategies in magnetic resonance elastography. NMR Biomed. 2018, e3919. [Google Scholar] [CrossRef] [PubMed]
  34. Fovargue, D.; Nordsletten, D.; Sinkus, R. Stiffness reconstruction methods for MR elastography. NMR Biomed. 2018, e3935. [Google Scholar] [CrossRef] [PubMed]
  35. Zerhouni, E.A.; Parish, D.M.; Rogers, W.J.; Yang, A.; Shapiro, E.P. Human heart: Tagging with MR imaging--a method for noninvasive assessment of myocardial motion. Radiology 1988, 169, 59–63. [Google Scholar] [CrossRef] [PubMed]
  36. Moore, C.C.; O’Dell, W.G.; McVeigh, E.R.; Zerhouni, E.A. Calculation of three-dimensional left ventricular strains from biplanar tagged MR images. J. Magn. Reson. Imaging 1992, 2, 165–175. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  37. Khan, S.; Fakhouri, F.; Majeed, W.; Kolipaka, A. Cardiovascular magnetic resonance elastography: A review. NMR Biomed. 2017. [Google Scholar] [CrossRef]
  38. Kennedy, P.; Wagner, M.; Castera, L.; Hong, C.W.; Johnson, C.L.; Sirlin, C.B.; Taouli, B. Quantitative elastography methods in liver disease: Current evidence and future directions. Radiology 2018, 286, 738–763. [Google Scholar] [CrossRef] [PubMed]
  39. Hsu, C.; Caussy, C.; Imajo, K.; Chen, J.; Singh, S.; Kaulback, K.; Le, M.D.; Hooker, J.; Tu, X.; Bettencourt, R.; et al. Magnetic resonance vs. transient elastography analysis of patients with non-alcoholic fatty liver disease: A systematic review and pooled analysis of individual participants. Clin. Gastroenterol. Hepatol. 2018. [Google Scholar] [CrossRef] [PubMed]
  40. Park, C.C.; Nguyen, P.; Hernandez, C.; Bettencourt, R.; Ramirez, K.; Fortney, L.; Hooker, J.; Sy, E.; Savides, M.T.; Alquiraish, M.H.; et al. Magnetic resonance elastography vs. transient elastography in detection of fibrosis and noninvasive measurement of steatosis in patients with biopsy-proven nonalcoholic fatty liver disease. Gastroenterology 2017, 152, 598–607. [Google Scholar] [CrossRef] [PubMed]
  41. Tang, A.; Cloutier, G.; Szeverenyi, N.M.; Sirlin, C.B. Ultrasound elastography and mr elastography for assessing liver fibrosis: Part 1, principles and techniques. Am. J. Roentgenol. 2015, 205, 22–32. [Google Scholar] [CrossRef] [PubMed]
  42. Lucejko, M.; Flisiak, R. Effect of HCV core antigen and RNA clearance during therapy with direct acting antivirals on hepatic stiffness measured with shear wave elastography in patients with chronic viral hepatitis C. Appl. Sci. 2018, 8, 198. [Google Scholar] [CrossRef]
  43. Chan, J.; Gogela, N.; Zheng, H.; Lammert, S.; Ajayi, T.; Fricker, Z.; Kim, A.Y.; Robbins, G.K.; Chung, R.T. Direct-acting antiviral therapy for chronic HCV infection results in liver stiffness regression over 12 months post-treatment. Digest. Dis. Sci. 2017. [Google Scholar] [CrossRef] [PubMed]
  44. Knop, V.; Hoppe, D.; Welzel, T.; Vermehren, J.; Herrmann, E.; Vermehren, A.; Friedrich-Rust, M.; Sarrazin, C.; Zeuzem, S.; Welker, M.W. Regression of fibrosis and portal hypertension in HCV-associated cirrhosis and sustained virologic response after interferon-free antiviral therapy. J. Viral Hepat. 2016, 23, 994–1002. [Google Scholar] [CrossRef] [PubMed]
  45. Facciorusso, A.; Del Prete, V.; Turco, A.; Buccino, R.V.; Nacchiero, M.C.; Muscatiello, N. Long-term liver stiffness assessment in HCV patients undergoing antiviral therapy: Results from a 5-year cohort study. J. Gastroenterol. Hepatol. 2017, 33, 942–949. [Google Scholar] [CrossRef] [PubMed]
  46. Ogasawara, N.; Kobayashi, M.; Akuta, N.; Kominami, Y.; Fujiyama, S.; Kawamura, Y.; Sezaki, H.; Hosaka, T.; Suzuki, F.; Saitoh, S.; et al. Serial changes in liver stiffness and controlled attenuation parameter following direct-acting antiviral therapy against hepatitis C virus genotype 1b. J. Med. Virol. 2017, 90, 313–319. [Google Scholar] [CrossRef] [PubMed]
  47. Persico, M.; Rosato, V.; Aglitti, A.; Precone, D.; Corrado, M.; De Luna, A.; Morisco, F.; Camera, S.; Federico, A.; Dallio, M.; et al. Sustained virological response by direct antiviral agents in HCV leads to an early and significant improvement of liver fibrosis. Antivir. Ther. 2017, 23, 129–138. [Google Scholar] [CrossRef] [PubMed]
  48. Pons, M.; Santos, B.; Simon-Talero, M.; Ventura-Cots, M.; Riveiro-Barciela, M.; Esteban, R.; Augustin, S.; Genesca, J. Rapid liver and spleen stiffness improvement in compensated advanced chronic liver disease patients treated with oral antivirals. Ther. Adv. Gastroenterol. 2017, 10, 619–629. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  49. Sporea, I.; Lupusoru, R.; Mare, R.; Popescu, A.; Gheorghe, L.; Iacob, S.; Sirli, R. Dynamics of liver stiffness values by means of transient elastography in patients with HCV liver cirrhosis undergoing interferon free treatment. J. Gastrointest. Liver Dis. 2017, 26, 145–150. [Google Scholar] [CrossRef]
  50. Lee, C.; Wan, Y.; Hsu, T.; Huang, S.; Yu, M.; Lee, W.; Tsui, P.; Chen, Y.; Lin, C.; Tai, D. Interpretation US elastography in chronic hepatitis B with or without anti-HBV therapy. Appl. Sci. 2017, 7, 1164. [Google Scholar] [CrossRef]
  51. Baig, F.N.; Liu, S.Y.W.; Lam, H.; Yip, S.; Law, H.K.W.; Ying, M. Shear wave elastography combining with conventional grey scale ultrasound improves the diagnostic accuracy in differentiating benign and malignant thyroid nodules. Appl. Sci. 2017, 7, 1103. [Google Scholar] [CrossRef]
  52. Ignee, A.; Jenssen, C.; Arcidiacono, P.G.; Hocke, M.; Moller, K.; Saftoiu, A.; Will, U.; Fusaroli, P.; Iglesias-Garcia, J.; Ponnudurai, R.; et al. Endoscopic ultrasound elastography of small solid pancreatic lesions: A multicenter study. Endoscopy 2018. [Google Scholar] [CrossRef] [PubMed]
  53. Dietrich, C.F.; Sirli, R.; Ferraioli, G.; Popescu, A.; Sporea, I.; Pienar, C.; Kunze, C.; Taut, H.; Schrading, S.; Bota, S.; Schreiber-Dietrich, D.; Yi, D. Current Knowledge in Ultrasound-Based Liver Elastography of Pediatric Patients. Appl. Sci. 2018, 8, 944. [Google Scholar] [CrossRef]

Share and Cite

MDPI and ACS Style

Dietrich, C.F.; Bamber, J.C. Editorial on the Special Issue of Applied Sciences on the Topic of Elastography. Appl. Sci. 2018, 8, 1232. https://doi.org/10.3390/app8081232

AMA Style

Dietrich CF, Bamber JC. Editorial on the Special Issue of Applied Sciences on the Topic of Elastography. Applied Sciences. 2018; 8(8):1232. https://doi.org/10.3390/app8081232

Chicago/Turabian Style

Dietrich, Christoph F., and Jeffrey C. Bamber. 2018. "Editorial on the Special Issue of Applied Sciences on the Topic of Elastography" Applied Sciences 8, no. 8: 1232. https://doi.org/10.3390/app8081232

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop