Abstract
Physical model tests were conducted to investigate the mechanical behavior of PET geostrip-reinforced back-to-back MSE walls under static loading and the influence of vertical reinforcement spacing. Two reinforcement spacings were considered, and bilateral staged surcharges of 20–120 kPa were applied at the wall top. Settlement, facing displacement, reinforcement tensile load, lateral earth pressure, and vertical stress were monitored. The results show that all responses increased with surcharge, while their overall spatial distribution patterns remained generally stable. Wall-top settlement exhibited a double-peak distribution, and under 120 kPa, the maximum settlement of Model B was about 46% greater than that of Model A. Facing displacement showed an S-shaped profile, with an inflection point near 0.6H. Increasing the reinforcement spacing from 0.15 to 0.30 m resulted in higher tensile loads in individual reinforcement layers in the upper-middle region under the investigated conditions. Lateral earth pressure varied nonlinearly with height and peaked at about 0.77H. Vertical stress attenuated beneath the loading zones and was redistributed within the backfill. Overall, larger reinforcement spacing increased settlement, facing displacement, and reinforcement load, but had limited influence on the basic spatial response patterns.
1. Introduction
In recent years, reinforced soil structures have been widely used in various civil engineering applications, including highways, ports and waterways, hydraulic engineering, and railways. Among them, back-to-back MSE walls have attracted considerable attention because of their nearly vertical facings and high applicability to narrow, high-fill embankments [1,2,3]. A back-to-back MSE wall mainly consists of facing panels, reinforcements, and backfill. The two vertical facings are connected by reinforcements extending across the wall section. Under self-weight and external loading, the reinforcements develop tensile forces to resist the lateral earth pressure, allowing the reinforcement–backfill–facing system to act as an integrated composite structure that jointly carries the backfill weight and surcharge loads.
Vadavadagi et al. [4] and Jacobs et al. [5] investigated the effects of reinforcement layout, reinforcement ratio, number of reinforcement layers, and overlap length on wall displacement and earth pressure distribution through model-box tests. The results showed that increasing the reinforcement ratio and number of reinforcement layers, optimizing the reinforcement arrangement, and extending the overlap length could effectively reduce facing displacement, limit the potential failure zone, and decrease lateral earth pressure, highlighting the importance of structural optimization for improving overall wall stability. Mari et al. [6], based on laboratory tests and field measurements, reported that backfill compaction and matric suction significantly affect the shear strength and stress–strain response of highly reinforced soil walls. Balakrishnan et al. [7] further found that increasing water content weakens the shear and pullout resistance of the soil–reinforcement interface. From the perspective of backfill improvement, Ramirez et al. [8] showed that cohesive soil mixed with waste-tire rubber particles exhibits relatively high shear strength and low unit weight, making it a promising alternative backfill for reinforced soil walls. These studies demonstrate that hydraulic conditions and material properties can continuously influence the long-term performance of reinforced soil walls by altering soil strength and stress distribution.
From the perspective of interface behavior and micromechanical mechanisms, Vieira et al. [9] conducted large-scale direct shear and pullout tests to systematically evaluate the effects of confining pressure, normal stress, and transverse-rib spacing on soil–reinforcement interface shear and pullout behavior. They showed that interface strength and deformation characteristics are highly sensitive to external stress conditions and reinforcement configuration. Sarkar et al. [10], using static and dynamic triaxial tests, demonstrated that geogrid reinforcement can improve peak strength, cohesion, energy absorption capacity, dynamic modulus, and resistance to cumulative deformation. Bhushan et al. [11] investigated the influence of wall width on the stability and lateral earth pressure distribution of double-sided reinforced soil walls and proposed a method for calculating the active earth pressure coefficient. They found that the critical angle of the failure wedge decreases with decreasing wall width-to-height ratio. Sravanam et al. [12] employed FLAC numerical models to investigate the effects of surcharge and compaction stress on the behavior of double-sided reinforced soil walls, with particular emphasis on the influences of wall aspect ratio and reinforcement stiffness on earth pressure, facing displacement, and maximum reinforcement tensile load along the wall height. Their results indicated that surcharge and construction-induced compaction stress significantly modify the internal stress redistribution, while reinforcement stiffness and structural geometry play important roles in deformation control.
Vadavadagi et al. [13] combined finite element analysis with machine learning to predict reinforcement tensile loads in double-sided reinforced soil walls. The predictive performance was evaluated using statistical indices such as root mean square error and absolute error, showing that the integration of numerical simulation and intelligent prediction can improve the efficiency and reliability of structural response analysis. El-Sherbiny et al. [14] employed a two-dimensional finite element model validated against large-scale tests to further investigate the effects of wall spacing and reinforcement length on failure mode, lateral earth pressure, reinforcement tensile load, and overall stability. The results indicated that decreasing the wall spacing reduced both lateral earth pressure and reinforcement tensile load while increasing the factor of safety. Anderson et al. [15] systematically reviewed the development, structural configurations, and design methods of back-to-back MSE walls through theoretical analysis, numerical simulation, field monitoring, and engineering case studies. They concluded that reinforcement overlap can enhance the interaction between the two reinforced zones, and existing engineering applications have demonstrated that relatively narrow back-to-back MSE walls can still maintain satisfactory static and dynamic performance. Subsequently, Sravanam et al. [16] further investigated the effects of reinforcement connection mode and stiffness using FLAC numerical models, comparing the behavior of connected and unconnected back-to-back MSE walls under working stress conditions. Recent experimental studies have further investigated the influence of reinforcement configuration on the mechanical behavior of back-to-back MSE walls. Yazdandoust and Daftari [17] conducted twelve physical model tests to examine the effects of reinforcement type and arrangement on the behavior of back-to-back MSE walls supporting railway embankments. Their results demonstrated that reinforcement stiffness and continuity significantly influenced bearing capacity, facing deformation, and failure mechanisms. More recently, Alsharari et al. [18] investigated five reinforcement configurations under static footing loading and demonstrated the importance of reinforcement continuity in controlling bearing capacity, reinforcement strain, lateral earth pressure, and facing deformation. These studies have provided valuable experimental evidence regarding reinforcement arrangement and wall interaction. However, the influence of vertical reinforcement spacing on the spatial distributions of deformation, reinforcement tensile load, and internal stresses in PET geostrip-reinforced back-to-back MSE walls under bilateral static loading requires further investigation.
Back-to-back MSE walls employ tensile reinforcements embedded in the backfill. On the one hand, the reinforcement tensile load restrains facing displacement; on the other hand, the confinement provided by the reinforcement produces a netting effect, thereby reducing stresses within the backfill. After construction, self-weight settlement of the backfill induces deformation in the reinforcement, which is equivalent to introducing a certain prestressing effect and further enhances the restraint on the outer facing panels. Compared with conventional retaining walls connected by tie rods, back-to-back MSE walls use flexible reinforcement materials, enabling them to adapt to foundations with relatively low bearing capacity while also providing favorable seismic performance. Owing to this distinctive structural configuration, the required slope width on both sides can be significantly reduced, providing an effective solution for projects with limited construction space or scarce land resources. Previous studies have demonstrated that the mechanical behavior of back-to-back MSE walls is influenced by wall geometry, reinforcement configuration, reinforcement stiffness, and external loading conditions. In particular, reinforcement continuity plays an important role in the interaction between opposing facings and the reinforced backfill. Recent physical model tests have also investigated the dynamic behavior of PET geostrip-reinforced back-to-back MSE walls under bilateral cyclic loading [19]. Nevertheless, the static and cyclic loading responses represent different loading conditions. A detailed understanding of the deformation and internal force distributions under staged static loading is necessary to characterize the static behavior of this structural system. In particular, the influence of vertical reinforcement spacing on the coupled variations in wall-top settlement, facing displacement, reinforcement tensile load, lateral earth pressure, and vertical stress has not been fully established for continuous PET geostrip-reinforced back-to-back MSE walls.
Environmental sustainability has become an important consideration in geotechnical engineering. Morsy and Thakeb [20] conducted a life cycle assessment of geosynthetic-reinforced MSE walls and conventional retaining structures, highlighting the influence of material selection and structural configuration on environmental impacts. Similarly, Pujadas-Gispert et al. [21] demonstrated that construction methods, foundation types, and structural design provisions affect the environmental performance of shallow foundations. For deep foundations, Abushama et al. [22] investigated the potential for reducing embodied carbon through the optimization of pile materials and geometry. However, the practical implementation of low-carbon geotechnical solutions remains challenging. Abushama et al. [23] identified cost considerations, limited ground investigation data, construction constraints, and concerns regarding long-term performance as barriers to the adoption of low-carbon foundation designs. These studies highlight the importance of considering structural performance, material efficiency, and practical implementation when developing geotechnical solutions.
At present, research on back-to-back MSE walls remains limited, particularly with respect to their mechanical response under static loading. Therefore, physical model tests are needed to investigate the mechanical response and deformation characteristics of back-to-back MSE walls subjected to static loads. The resulting findings can help optimize structural design and provide a theoretical basis and technical support for the application of back-to-back MSE walls in practical engineering. To address these issues, the present study investigates the static behavior of PET geostrip-reinforced back-to-back MSE walls through physical model tests. The investigation proceeds in four stages. First, sieve analysis, compaction tests, and consolidated drained triaxial tests are conducted to characterize the backfill, while tensile tests establish the mechanical properties of the prototype and model PET geostrips. Second, two wall models (Models A and B) are constructed with vertical reinforcement spacings of 0.15 and 0.30 m, respectively. Third, bilateral symmetric static surcharges are applied incrementally, and wall-top settlement, facing displacement, reinforcement tensile load, lateral earth pressure, and vertical stress are systematically monitored. Finally, the mechanical responses of the two models are compared to quantify the effects of reinforcement spacing and surcharge level on the magnitude and spatial distribution of these responses. By systematically examining the deformation and internal force distributions under bilateral staged static loading, this study provides experimental evidence for understanding the influence of reinforcement spacing on the static behavior of continuous PET geostrip-reinforced back-to-back MSE walls.
2. Physical and Mechanical Properties of Test Materials
The physical and mechanical properties of the backfill were investigated through sieve analysis, compaction tests, and triaxial tests to determine parameters such as cohesion and internal friction angle. Tensile tests were conducted on the polyester (PET) geostrips to determine their tensile strength.
2.1. Sieve Analysis
Clean natural river sand was used as the backfill material. Sieve analysis was conducted using standard test sieves with aperture sizes ranging from 20 to 0.075 mm, as shown in Figure 1. A 5 kg sand sample was sieved using a standard mechanical sieve shaker. After sieving, the mass of soil retained on each sieve was measured, and the percentage of particles finer than each particle size was calculated relative to the total sample mass. Based on these results, the particle size distribution curve was obtained.
Figure 1.
Standard mechanical sieve shaker.
The percentage of the sample mass finer than a given particle size was calculated as follows:
where is the percentage of the sample mass finer than a given particle size relative to the total sample mass, is the mass of the sample finer than a given particle size, is the total mass of the sample used for sieve analysis, and is the percentage of particles finer than 2 mm or 0.075 mm relative to the total sample mass.
After sieve analysis, the particle size distribution curve of the soil is shown in Figure 2. According to the engineering soil classification criteria, particles larger than 0.25 mm account for less than 50% of the total mass, while particles larger than 0.075 mm account for more than 85%; therefore, the test soil is classified as fine sand. The calculated coefficient of uniformity, Cu, is 2.405, and the coefficient of curvature, Cc, is 0.941. Accordingly, the soil is classified as poorly graded fine sand.
Figure 2.
Particle size distribution curve of natural river sand.
2.2. Compaction Test
The maximum dry density and optimum water content are important parameters for wall backfill construction. A 2.5 kg rammer was used for the compaction test. The soil sample was compacted in three layers, with 25 blows applied to each layer to ensure uniform compaction. After each layer was compacted, its surface was scarified to improve bonding between adjacent layers and prevent stratification of the specimen.
After oven-drying the test soil, five target water contents were prepared at 2% intervals, namely 4%, 6%, 8%, 10%, and 12%. The prepared specimens were sealed for 12 h to ensure a uniform moisture distribution. After compaction, the specimens were weighed to determine their mass and dry density. The soil was then oven-dried again and reweighed to verify the dry density and water content. If discrepancies were found between the two determinations, the test was repeated. The test results are presented in Table 1.
Table 1.
Compaction test results.
The dry density of each specimen after compaction was calculated as follows:
where is the dry density, is the water content, and is the measured density of the specimen.
As shown in Figure 3, the compaction curve was fitted to determine the maximum dry density and optimum water content. The maximum dry density of the test sand was 1.72 g/cm3, and the optimum water content was 8%.
Figure 3.
Compaction curve.
2.3. Triaxial Test
Because the backfill consisted of sand with relatively high permeability, truly undrained conditions were difficult to maintain at conventional triaxial shearing rates, as drainage could still occur during testing. Therefore, consolidated drained (CD) triaxial tests were conducted. As shown in Figure 4a, a fully automatic triaxial apparatus was used. Three specimens were prepared at the optimum water content, with a height-to-diameter ratio of 2.5. Confining pressures of 100, 200, and 300 kPa were applied, respectively. The tests were controlled by computer software and terminated when the axial strain reached 16%. The failure patterns of the specimens are shown in Figure 4b.
Figure 4.
Triaxial test: (a) Fully automatic triaxial apparatus. (b) Failure pattern of the soil specimen.
The Mohr circles corresponding to the three confining pressures were constructed using the principal stresses at failure, as shown in Figure 5. The Mohr–Coulomb failure envelope was used to characterize the shear strength of the backfill. The internal friction angle and cohesion were determined from the experimental stress data, while Figure 5 provides a graphical illustration of the relationship between the Mohr circles and the failure envelope. The strength envelope was then fitted to the Mohr circles. The internal friction angle of the specimen was determined from the inclination of the strength envelope, while the cohesion was obtained from its intercept on the shear-stress axis. The backfill used in the tests had an internal friction angle of 37° and a cohesion of 3 kPa.
Figure 5.
Mohr circles and Mohr–Coulomb failure envelope of the backfill.
2.4. Reinforcement Tensile Test
Back-to-back MSE walls are conceptually similar to conventional reinforced soil walls in that the tensile resistance of the reinforcement is mobilized to balance the lateral earth pressure generated by the backfill, thereby restraining the lateral displacement of the facing panels. However, the mechanisms by which reinforcement tensile loads are mobilized differ substantially between the two systems. The stability of conventional reinforced soil walls mainly depends on soil–reinforcement interaction. In contrast, the reinforcements in back-to-back MSE walls extend across the entire wall section and are anchored to the facing panels on both sides, making reinforcement tensile capacity one of the key factors governing structural stability. Therefore, tensile testing of the reinforcement is essential for accurately determining its tensile strength and deformation characteristics and for ensuring the stability of back-to-back MSE walls.
In this study, tensile tests on the PET geostrips were conducted using an electronic testing machine for geosynthetic materials, as shown in Figure 6. The equipment uses a servo motor to drive the crosshead vertically through a gear transmission system, thereby applying tensile loading to the specimen. The testing machine continuously records stress and strain throughout the test until specimen failure.
Figure 6.
Electronic tensile testing machine for geosynthetics.
As shown in Figure 7, PET geostrips were used as the reinforcement material. Each geostrip consists of an outer polyethylene protective coating and three internal bundles of polyester fibers. The geometric dimensions of the geostrips are listed in Table 2.
Figure 7.
PET geostrip used in the tests.
Table 2.
Basic physical properties of the PET geostrip.
PET geostrip specimens were randomly cut along the production direction, with a specimen length of 500 mm. The gripping length at each end was not less than 100 mm, as shown in Figure 8. At least three specimens were tested. If slippage occurred during the tensile test, the corresponding data were discarded, and an additional test was conducted.
Figure 8.
Reinforcement tensile test: (a) Before tensile testing. (b) After tensile testing.
According to the test results shown in Figure 9, the tensile load dropped sharply three times after reaching its peak value. This behavior was attributed to the three bundles of polyester fibers encapsulated within the geostrip. Once the strain of each fiber bundle reached its peak value, the bundles fractured rapidly and sequentially. Although the outer polyethylene protective layer continued to sustain part of the tensile load and maintained the overall shape of the geostrip, the tensile test was considered complete at this stage.
Figure 9.
Tensile load–strain relationship of the PET geostrip: (a) Prototype; (b) model.
To ensure the mechanical similarity between the prototype and model reinforcements, tensile tests were conducted on both prototype and model PET geostrips. The geometric similarity ratio between the prototype and the model was 6. Under normal gravitational acceleration, assuming approximately equal unit weights of the prototype and model backfills and a strain similarity ratio of unity, the stress similarity ratio is equal to the geometric similarity ratio. Since the reinforcement tensile stiffness per unit width is defined as the tensile load per unit width divided by strain, its theoretical similarity ratio is the square of the geometric similarity ratio, 36. As shown in Table 3, the measured tensile stiffnesses of the prototype and model PET geostrips were 6246.3 and 187.7 kN/m, respectively, corresponding to an experimental similarity ratio of 33.28. The relative difference between the experimental and theoretical stiffness similarity ratios was approximately 7.56%. In addition, the prototype-to-model ratios of tensile load per unit width at strains of 2% and 5% were 34.49 and 33.92, respectively. These results indicate that the selected model PET geostrip approximately satisfies the theoretical stiffness similarity requirement and is suitable for the comparative physical model tests conducted in this study. The tensile tests were conducted to characterize the mechanical properties of the PET geostrips. The soil–reinforcement interface properties were not independently determined through pullout or direct shear tests in the present study.
Table 3.
Analysis of PET Geostrip Tensile Test Results.
3. Model Establishment
3.1. Model Test Setup
As shown in Figure 10, the model box is 3.0 m long, 1.5 m wide, and 2.0 m high. One longitudinal side consists of a steel support plate, while the opposite side is an observation window composed of I-beams and tempered glass, allowing direct observation of wall deformation during testing. Rigid tie rods are installed along the short side at the top of the model box, and the bottom of the box is fixed to the base plate of the loading frame.
Figure 10.
Model box of the test system.
The load is applied using an electro-hydraulic servo multi-point loading system, and different loading conditions can be simulated by adjusting the loading parameters. The system is equipped with three actuators that can operate either synchronously or independently. The actuators are vertically mounted on the top frame beam and arranged along the longitudinal direction of the model box, with both load-control and displacement-control modes available. The central actuator has a maximum loading capacity of ±100 kN, while the two side actuators each have a maximum loading capacity of ±50 kN, with an accuracy class of 0.5. The piston stroke is 200 mm, the displacement sensor has an accuracy of 0.01 mm, and the loading frequency ranges from 0.1 to 20 Hz.
As shown in Figure 11, the main monitoring instruments embedded within the wall model include strain-gauge earth pressure cells, strain gauges, and single-point displacement transducers. The installation layout of these monitoring instruments is described in the following section.
Figure 11.
Monitoring instruments used in the model test: (a) strain-gauge earth pressure cell; (b) LVDT displacement transducer; (c) strain gauge.
3.2. Model Geometry and Monitoring Scheme
The geometric similarity ratio of 1:6 was adopted to reproduce the prototype wall geometry within the available model box while maintaining an appropriate reinforcement stiffness similarity. The similarity ratio of a physical quantity was defined as the ratio of its prototype value to the corresponding model value. Under normal gravitational conditions, assuming approximately equal unit weights of the prototype and model backfills and a strain similarity ratio of unity, the theoretical stress similarity ratio is equal to the geometric similarity ratio. Accordingly, the theoretical similarity ratios for displacement, surcharge pressure, and reinforcement tensile stiffness per unit width are 6, 6, and 36, respectively. The theoretical similarity relationships for geometry, stress, displacement, reinforcement stiffness and tensile load, surcharge, facing properties, and relevant soil parameters are summarized in Table 4. As shown in Table 3, the measured tensile stiffnesses of the prototype and model PET geostrips were 6246.3 and 187.7 kN/m, respectively, corresponding to an experimental similarity ratio of 33.28. The relative difference between the experimental and theoretical stiffness similarity ratios was approximately 7.56%, indicating reasonable agreement with the theoretical requirement. Two vertical reinforcement spacings of 0.15 and 0.30 m were selected to investigate the influence of reinforcement spacing on the static behavior of the wall. The larger spacing is twice the smaller spacing, allowing the effects of a reduced number of reinforcement layers per unit wall height on deformation and internal force distributions to be examined. The two models were constructed with the same overall geometry, backfill material, and reinforcement type to facilitate a consistent comparison of their mechanical responses.
Table 4.
Similarity ratios adopted in the model test.
denotes the geometric scale ratio of the prototype to the physical model, and denotes the governing parameter, which is assumed to be 0.5 in this study.
The wall model used in this study had a length of 2.0 m, a width of 1.5 m, and a height of 1.65 m. The projected reinforcement length along the observation direction was 1.8 m. Two vertical reinforcement spacings, 0.15 and 0.30 m, were adopted for Model A and Model B, respectively. The modular facing panels were 0.1 m thick. To simulate the strip foundation used in practical engineering, cement mortar was cast at the base of the wall model. To ensure the integrity of the modular facing panels during construction and testing, the panels were fabricated and cured according to the mix proportion of C20 concrete blocks. Adjacent concrete blocks were vertically stacked using interlocking tongue-and-groove joints until wall construction was completed. Two U-shaped rings were embedded in the middle of each facing panel, allowing the PET geostrips to pass through the rings and connect to the modular panels, as shown in Figure 12.
Figure 12.
Installation of Modular Facing Panels and PET Geostrips.
The physical model design and instrumentation layout of the wall are shown in Figure 13. Identical sensors were symmetrically arranged within the wall to improve the reliability and accuracy of the test results.
Figure 13.
Layout of PET Geostrips and Monitoring Points in the Back-to-Back MSE Wall.
As shown in Figure 13, the single-point displacement transducers installed outside the left and right facings are denoted as LD and RD, respectively, and are positioned at the same elevations as the internal monitoring points. Inside the wall, monitoring points were arranged at heights of 0.075, 0.375, 0.675, 0.975, 1.275, and 1.575 m. Five monitoring points were installed at each elevation, giving a total of 30 monitoring points. Taking the elevation of 1.575 m as an example, the detailed locations of the monitoring instruments within the wall are shown in Figure 14.
Figure 14.
Plan View of PET Geostrips and Instrumentation Layout at a Wall Height of 1.575 m.
Clean natural river sand was used as the backfill material for both wall models. According to the laboratory compaction test, the maximum dry density and optimum water content of the sand were 1.72 g/cm3 and 8%, respectively. To ensure comparable initial backfill conditions, the backfill was placed and compacted in successive layers, with a compacted lift thickness of 0.15 m. The relative compaction of both Models A and B was 96%. During construction, the modular facing panels were progressively installed, and the PET geostrips were connected to the facings at the designated elevations. The backfill was then placed and compacted layer by layer until the designed wall height was reached. The same backfill preparation, compaction procedure, and construction sequence were adopted for both models to minimize differences in their initial conditions and facilitate a consistent comparison of their static responses.
During the tests, protective measures were adopted to prevent coarse gravel particles from damaging the monitoring instruments and affecting data accuracy. Before installing the earth pressure cells, relatively large gravel particles around the sensors were removed and replaced with fine sand to ensure uniform contact and reduce local stress concentration. Strain gauges were bonded to the PET geostrip surface in advance and covered with white adhesive for protection. The wiring connections were wrapped with plastic film and insulating tape to prevent damage during backfilling and testing. During installation, the single-point displacement transducers were carefully adjusted to remain horizontally level and vertically aligned, and were fixed to the supporting steel frame with insulating tape to ensure that the probe remained in contact with the modular facing panel. The detailed protective measures and instrumentation arrangement are shown in Figure 15.
Figure 15.
Installation of Monitoring Instruments: (a) strain-gauge earth pressure cell; (b) LVDT displacement transducer; (c) strain gauge.
The data acquisition system employed a Dongfang dynamic data acquisition system, which can simultaneously collect data on facing displacement, earth pressure, and reinforcement strain, as shown in Figure 16.
Figure 16.
Dynamic data acquisition system.
3.3. Loading Scheme
This study mainly considered the surcharge load encountered in practical engineering. As shown in Figure 17, the load was applied using an electro-hydraulic servo multi-point loading system. The loading plate measured 40 cm × 70 cm × 2 cm (length × width × height).
Figure 17.
Electro-hydraulic servo multi-point loading system.
According to the provisions on track and train loads for different railway types in the Code for Design of Retaining Structures of Railway Earthworks (TB 10025-2019) [24], together with measured subgrade surface stresses reported for high-speed railways in China and abroad [25], the representative subgrade surface stresses were summarized in Table 5. Based on these values, six prototype-equivalent surcharge levels ranging from 20 to 120 kPa at increments of 20 kPa were selected to investigate the progressive changes in structural response with increasing load. Bilateral symmetric loading was adopted to characterize the static behavior of the back-to-back MSE wall under comparable loading conditions on both sides, while minimizing the influence of loading asymmetry. Considering a geometric similarity ratio of 1:6 between the model and prototype, the prototype-equivalent surcharges of 20, 40, 60, 80, 100, and 120 kPa corresponded to model surcharges of 3.33, 6.67, 10.00, 13.33, 16.67, and 20.00 kPa, respectively. These six levels of static surcharge were incrementally applied to both sides of the wall top. As shown in Figure 18, data were recorded every 20 min after each load level was applied. The next load level was imposed when two consecutive measurements were nearly identical, indicating that the wall deformation had stabilized. For convenience of presentation and comparison, all surcharge levels reported in the following sections and figures are expressed as prototype-equivalent values unless otherwise specified.
Table 5.
Subgrade surface stress.
Figure 18.
Static loading method.
4. Static Load Test Results and Analysis of the Physical Model
4.1. Settlement
Figure 19 presents the distribution of wall-top settlement across the wall width under different static surcharge levels. For both models, the settlement increased markedly with increasing surcharge and exhibited a stable double-peak pattern. The peak settlements occurred mainly within the loading zones, while a distinct trough formed at the wall center, indicating a pronounced local concentration of vertical deformation induced by the surcharge. When the vertical load reached 120 kPa, the maximum settlements of Model A and Model B were approximately 2.42 and 3.53 mm, respectively, corresponding to about 3.0 and 3.6 times the settlement at the wall center. The difference between the two models also became more pronounced as the surcharge increased; at 120 kPa, the peak settlement of Model B was about 46% greater than that of Model A. In addition, the settlements at corresponding locations on the two sides were nearly identical, indicating good symmetry of wall deformation under bilateral static loading. Under the investigated loading conditions, Model B exhibited greater local settlement and more pronounced differential deformation than Model A, particularly within the loading zones. These observations suggest that the larger reinforcement spacing may be associated with reduced restraint on vertical deformation.
Figure 19.
Distribution of Wall-Top Settlement under Different Static Surcharge Levels.
4.2. Horizontal Facing Displacement
Figure 20 shows the distribution of horizontal facing displacement with wall height for Models A and B under different static surcharge levels. In this study, outward displacement of the facing is defined as positive, while inward displacement toward the reinforced backfill is defined as negative. This sign convention is applied consistently to both facings. Under all surcharge levels, the horizontal facing displacement exhibited a distinct S-shaped distribution along the wall height. The lower part of the facing displaced inward, whereas the upper part displaced outward. The displacement was close to zero at a wall height of approximately 0.975 m, indicating a transition between inward and outward displacement near 0.6H. Overall, the two models exhibited similar displacement profiles, with the displacement magnitude increasing gradually as the surcharge increased. As the surcharge increased from 20 to 120 kPa, the displacement amplitudes at the upper and lower parts of the wall increased continuously, whereas the inflection point remained nearly unchanged, indicating that the surcharge level mainly affected the magnitude of deformation rather than the overall deformation mode.
Figure 20.
Distribution of Horizontal Facing Displacement under Different Static Surcharge Levels.
Compared with Model A, Model B generally exhibited larger horizontal facing displacements, and the difference became more evident with increasing surcharge. Under 120 kPa, the maximum displacements of Models A and B were approximately 0.27 and 0.31 mm, respectively, with Model B being about 15% greater. Meanwhile, the inflection positions of the two models were nearly identical, indicating that increasing the vertical reinforcement spacing mainly increased the deformation magnitude without significantly altering the S-shaped displacement pattern. This suggests that a larger reinforcement spacing weakens the lateral restraint provided by the reinforced soil mass, thereby increasing facing displacement.
4.3. Reinforcement Tensile Load
Figure 21 presents the distribution of reinforcement tensile load along the wall width at different elevations under various static surcharge levels. Overall, the tensile load in each reinforcement layer increased to varying degrees as the surcharge increased from 20 to 120 kPa, indicating a clear dependence of reinforcement response on the applied static surcharge. Models A and B exhibited generally similar tensile-load distribution patterns; however, the tensile loads in Model B were consistently higher than those in Model A, particularly at higher surcharge levels. This indicates that increasing the vertical reinforcement spacing causes each reinforcement layer to carry a greater share of the applied load.
Figure 21.
Reinforcement Tensile Load Distributions under Different Static Surcharge Levels and Vertical Reinforcement Spacings: (a) Layer 11; (b) Layer 9; (c) Layer 7; (d) Layer 5; (e) Layer 3; (f) Layer 1.
Along the wall height, the tensile-load distribution patterns differed markedly among the reinforcement layers. In the uppermost Layer 11, the tensile load exhibited a single-peak distribution across the wall width, with larger values in the central region and smaller values near the two sides; the maximum occurred close to the wall center. Under a surcharge of 120 kPa, the peak tensile loads in Models A and B were approximately 0.18 and 0.26 kN, respectively. At Layer 9, a distinct double-peak distribution began to develop, with the peaks mainly located beneath the two static loading zones. This double-peak pattern became most pronounced at Layer 7, where the tensile load in the central region decreased markedly while higher peaks formed beneath the two loading zones; under 120 kPa, the peak value in Model B was approximately 1.5 times that in Model A. With decreasing elevation, the tensile-load peaks gradually shifted toward the two facings. Layers 5, 3, and 1 all exhibited a clear “lower in the middle and higher near the sides” pattern, particularly in Layers 3 and 1, where the tensile load was relatively small in the central region but increased markedly near the facings. These results indicate that, as the static surcharge diffused downward, its influence gradually expanded. The observed variation in reinforcement tensile-load distribution may be associated with the combined effects of facing restraint, soil–reinforcement interaction, and the continuous tensile behavior of the through-going reinforcement. However, the individual contributions of these mechanisms cannot be quantitatively distinguished from the present measurements.
The results indicate that changing the vertical reinforcement spacing mainly affected the magnitude of reinforcement tensile load, while having relatively little influence on the basic distribution pattern across the wall width at each layer. The increase in tensile load in Model B was particularly evident in the upper-middle layers, such as Layers 11, 9, and 7. This suggests that when the vertical reinforcement spacing increased from 0.15 to 0.3 m, the number of reinforcement layers participating in load resistance per unit wall height decreased, causing the external load to be carried by fewer reinforcement layers and thereby increasing the tensile load in each layer. In contrast, although the tensile loads in Model B were still generally higher than those in Model A at the lower Layers 3 and 1, the absolute differences between the two models were relatively small. Overall, both static surcharge level and vertical reinforcement spacing significantly influenced the reinforcement response. Increasing the surcharge mainly increased the tensile-load magnitude in all layers, whereas increasing the reinforcement spacing further increased the load carried by each layer. Along the wall height, the tensile-load distribution gradually changed from a central-peak or double-peak pattern in the upper part to a pattern characterized by higher values near the two facings and lower values in the central region at lower elevations. The results suggest that a smaller reinforcement spacing may help reduce the tensile load carried by individual reinforcement layers under comparable loading conditions.
4.4. Lateral Earth Pressure Behind the Facing
Figure 22 presents the distribution of lateral earth pressure behind the facings along the wall height for Models A and B under different static surcharge levels. Overall, the lateral earth pressure distributions were similar for the two reinforcement spacings and showed good symmetry between the left and right sides. When the static surcharge increased to 120 kPa, the lateral earth pressure increased overall, with the most pronounced increase occurring in the upper part of the wall. Under all surcharge levels, the lateral earth pressure did not follow the conventional linear triangular distribution but exhibited a clear nonlinear pattern. The maximum value occurred at approximately 0.77H, whereas a minimum appeared near 0.6H. This indicates that the lateral stress induced by the static surcharge was mainly concentrated in the upper-middle portion of the wall.
Figure 22.
Distribution of Lateral Earth Pressure behind the Facing under Static Loading with Different Vertical Reinforcement Spacings: (a) Model A; (b) model B.
4.5. Vertical Stress
Figure 23 shows the vertical stress distribution along the wall height under static loading for different vertical reinforcement spacings. The results indicate that Models A and B exhibited similar vertical stress trends in the regions behind the facing, beneath the loading zones, and at the wall center, although clear differences existed among these locations. In the loading zones, the vertical stress gradually decreased from the wall top downward, and the increase in stress within the upper-middle portion became more pronounced as the surcharge increased. Under 120 kPa, the maximum vertical stress near the wall top was approximately 20 kPa, while the stress increment became much smaller below about 0.4H, indicating that the influence of the static surcharge was mainly concentrated within the upper 0.9 m of the wall. In the regions behind the facing and at the wall center, the vertical stress reached its maximum at approximately 0.6H, with the maximum value in the central region being clearly higher than that behind the facing. This indicates that the bilaterally symmetric surcharge diffused downward and inward, resulting in pronounced stress accumulation within the wall interior.
Figure 23.
Vertical Stress Distribution under Static Loading with Different Vertical Reinforcement Spacings: (a) behind the wall. (b) Beneath the loading zone. (c) Centerline position.
The overall distribution patterns of Models A and B were generally similar; however, Model B showed slightly higher vertical stresses in some upper-middle regions, and the difference became more evident under higher surcharge levels. This difference may be associated with the reduced number of reinforcement layers per unit wall height, which may alter the restraint on vertical deformation and the redistribution of stresses within the reinforced soil mass. Overall, the vertical reinforcement spacing mainly affects the degree of stress diffusion and redistribution within the reinforced soil mass, while having relatively little influence on the basic vertical stress distribution along the wall height.
5. Discussion
- (1)
- Wall-top settlement increased significantly with increasing static surcharge and exhibited a double-peak distribution across the wall width. Under 120 kPa, the maximum settlement of Model B was approximately 3.53 mm, about 46% greater than that of Model A, indicating that increasing the vertical reinforcement spacing aggravates settlement in the loading zones.
- (2)
- The horizontal facing displacement showed an S-shaped distribution along the wall height, with an inflection point at approximately 0.6H. Under 120 kPa, the maximum displacement of Model B was about 15% greater than that of Model A, indicating that increasing the reinforcement spacing mainly increases the deformation magnitude while having little influence on the overall deformation mode.
- (3)
- Reinforcement tensile load increased with increasing static surcharge, and the dominant load-bearing region gradually shifted from the upper loading zones toward the vicinity of the two facings at lower elevations. Increasing the vertical reinforcement spacing from 0.15 to 0.3 m significantly increased the tensile load carried by individual reinforcement layers, indicating that reducing the reinforcement spacing is beneficial for distributing the external load.
- (4)
- The lateral earth pressure behind the facing exhibited a nonlinear distribution along the wall height, with relatively large values concentrated in the upper-middle portion and a peak occurring at approximately 0.77H. Increasing the reinforcement spacing slightly increased the lateral earth pressure in some upper-middle regions but had little influence on the overall distribution pattern.
- (5)
- Vertical stress exhibited clear spatial differences and attenuated with depth. The stress beneath the loading zones decreased progressively downward, while relatively large values occurred near 0.6H in the central region. Increasing the reinforcement spacing slightly increased the local vertical stress, indicating that reinforcement spacing mainly affects load diffusion and redistribution within the reinforced soil mass.
The present study has several limitations that should be considered when interpreting the experimental results. First, only two vertical reinforcement spacings (0.15 and 0.30 m) were examined. Although the results demonstrate the influence of reinforcement spacing on wall deformation and internal force distributions, they are insufficient to establish a general quantitative relationship or determine an optimal reinforcement spacing. Second, the tests were conducted using a 1:6 scale model under normal gravitational conditions. Differences in boundary conditions, material similarity, and construction conditions between the model and the prototype may affect the quantitative applicability of the experimental results to full-scale structures. Third, only bilateral symmetric static loading was considered. Therefore, the observed deformation and stress distributions may not be directly applicable to asymmetric loading, cyclic train loading, or long-term service conditions. Consequently, the present findings should be interpreted within the tested reinforcement configurations and loading conditions. Further investigations involving additional reinforcement spacings, full-scale measurements, and different loading conditions are needed to extend the applicability of the results and provide a more comprehensive basis for engineering design. Previous numerical studies [12,16] have shown that reinforcement configuration and wall interaction influence the mechanical response of back-to-back MSE walls. Consistent with the load-sharing concept in conventional MSE wall design, the present results show that increasing reinforcement spacing increases the tensile load carried by individual reinforcement layers. Meanwhile, the measured lateral earth pressure exhibited a nonlinear distribution, differing from the conventional earth-pressure distribution. This difference may be associated with the bilateral localized loading and the restraint provided by the continuous PET geostrips. However, the individual contributions of these mechanisms cannot be independently verified from the present measurements. Furthermore, the displacement transition near 0.6H and the lateral earth pressure peak near 0.77H correspond to discrete monitoring elevations and should be regarded as approximate locations.
6. Conclusions
This study investigates the static mechanical behavior of PET geostrip-reinforced back-to-back MSE walls through physical model tests, with particular emphasis on the influence of vertical reinforcement spacing. The results demonstrate that the through-going PET geostrips effectively connect the two facings and the reinforced backfill, enabling the wall system to resist external surcharge through the combined action of facing restraint, reinforcement tension, and internal stress redistribution. Although increasing the vertical reinforcement spacing does not fundamentally alter the overall deformation and stress distribution patterns, it increases wall-top settlement, facing displacement, and the tensile load carried by individual reinforcement layers, thereby weakening the load-sharing capacity of the reinforced soil mass. Specifically, under a prototype-equivalent surcharge of 120 kPa, increasing the reinforcement spacing from 0.15 to 0.30 m increased the maximum wall-top settlement and facing displacement by approximately 46% and 15%, respectively, while the peak tensile load in Layer 7 increased by approximately 50%. These differences indicate that reinforcement spacing has a more pronounced influence on wall-top settlement and the tensile load carried by individual reinforcement layers than on facing displacement under the investigated loading conditions. Meanwhile, the observed nonlinear lateral earth pressure distribution, with a peak near 0.77H, and the spatial redistribution of vertical stress further demonstrate the nonuniform internal mechanical response of the reinforced soil mass. The findings provide experimental evidence for understanding the load-transfer and deformation characteristics of PET geostrip-reinforced back-to-back MSE walls and highlight the importance of considering both deformation control and reinforcement tensile load when selecting reinforcement spacing. These results offer a useful basis for the rational selection of reinforcement spacing and the structural optimization of such walls in railway and other high-fill engineering applications, although their quantitative applicability to full-scale structures requires further verification.
Author Contributions
Conceptualization, X.L. and Y.Y.; methodology, X.L.; software, H.W.; validation, Y.Y., H.W., and G.Y.; formal analysis, X.L.; investigation, X.L.; resources, Y.Y.; data curation, H.W.; writing—original draft preparation, Y.Y.; writing—review and editing, X.L.; visualization, H.W.; supervision, G.Y.; project administration, G.Y.; funding acquisition, X.L. All authors have read and agreed to the published version of the manuscript.
Funding
This research was funded by the S&T Program of Hebei (23567602H).
Data Availability Statement
The data used to support the findings of this study are available from the corresponding author upon request.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Ren, F.; Liu, Q. Research Progress on the Characteristics of the Reinforcement-Soil Interface in Reinforced Soil Structures. West. China Commun. Sci. Technol. 2020, 24, 5–10+28. [Google Scholar]
- Wang, Y.; Yang, G.; Wang, L.; Li, X.; Jiao, G. Experimental Study on Reinforcement Properties of Tension-Resistant Reinforced Soil Retaining Wall. Buildings 2024, 14, 2951. [Google Scholar] [CrossRef] [Scilit]
- Connolly, D.P.; Marecki, G.P.; Kouroussis, G.; Thalassinakis, I.; Woodward, P.K. The growth of railway ground vibration problems-A review. Sci. Total Environ. 2016, 568, 1276–1282. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Vadavadagi, S.S.; Chawla, S. Effect of rail axle load on geosynthetic reinforced back-to-back mechanically stabilized earth walls: Experimental and numerical studies. Transp. Geotech. 2023, 38, 100907. [Google Scholar] [CrossRef] [Scilit]
- Jacobs, F.; Ruiken, A.; Ziegler, M. Investigation of kinematic behavior and earth pressure development of geogrid reinforced soil walls. Transp. Geotech. 2016, 8, 57–68. [Google Scholar] [CrossRef] [Scilit]
- Riccio, M.; Ehrlich, M.; Dias, D. Field monitoring and analyses of the response of a block-faced geogrid wall using fine-grained tropical soils. Geotext. Geomembr. 2014, 42, 127–138. [Google Scholar] [CrossRef] [Scilit]
- Balakrishnan, S.; Viswanadham, B. Performance evaluation of geogrid reinforced soil walls with marginal backfills through centrifuge model tests. Geotext. Geomembr. 2016, 44, 95–108. [Google Scholar] [CrossRef] [Scilit]
- Ramirez, G.G.D.; Casagrande, M.D.T.; Folle, D.; Pereira, A.; Paulon, V.A. Behavior of granular rubber waste tire reinforced soil for application in geosynthetic reinforced soil wall. Rev. IBRACON Estrut. Mater. 2015, 8, 567–576. [Google Scholar] [CrossRef] [Scilit]
- Vieira, C.; Lopes, M.; Caldeira, L. Sand-geotextile interface characterisation through monotonic and cyclic direct shear tests. Geosynth. Int. 2013, 20, 26–38. [Google Scholar] [CrossRef] [Scilit]
- Sarkar, S.; Hegde, A. Performance Evaluation of Geogrid Reinforced Recycled Marginal Backfill Materials in Triaxial Test Conditions. Int. J. Geosynth. Ground Eng. 2022, 8, 48. [Google Scholar] [CrossRef] [Scilit]
- Chauhan, V.B.; Srivastava, A.; Jaiswal, S.; Keawsawasvong, S. Behavior of Back-to-Back MSE Walls: Interaction Analysis Using Finite Element Modeling. Transp. Infrastruct. Geotechnol. 2022, 10, 888–912. [Google Scholar] [CrossRef] [Scilit]
- Sravanam, M.S.; Balunaini, U.; Madhav, R.M. Behavior and Design of Back-to-Back Walls Considering Compaction and Surcharge Loads. Int. J. Geosynth. Ground Eng. 2019, 5, 31. [Google Scholar] [CrossRef] [Scilit]
- Vadavadagi Shilpa, S.; Sowmiya, C.; Prince, K. Prediction and validation of geogrid tensile force distribution in back-to-back MSE walls under rail axle load: Finite-element and intelligent techniques. Environ. Earth Sci. 2024, 83, 149. [Google Scholar] [CrossRef] [Scilit]
- El-Sherbiny, R.; Ibrahim, E.; Salem, A. Stability of back-to-back mechanically stabilized earth walls. In Geo-Congress 2013: Stability and Performance of Slopes and Embankments III; American Society of Civil Engineers: Reston, VA, USA, 2013; pp. 555–565. [Google Scholar]
- Anderson, P.L.; Gladstone, R.A.; Brabant, K.; Sankey, J. Back-to-back MSE walls-a comprehensive understanding. In Innovations in Geotechnical Engineering; American Society of Civil Engineers: Reston, VA, USA, 2018; pp. 431–447. [Google Scholar]
- Sravanam, S.M.; Balunaini, U.; Madhira, R.M. Behavior of connected and unconnected back-to-back walls for bridge approaches. Int. J. Geomech. 2020, 20, 06020013. [Google Scholar] [CrossRef] [Scilit]
- Yazdandoust, M.; Daftari, F. Behavior of back-to-back mechanically stabilized earth walls as railway embankments. Geosynth. Int. 2024, 31, 785–805. [Google Scholar] [CrossRef] [Scilit]
- Alsharari, T.; Demirdogen, S.; Han, J. Experimental investigation of back-to-back MSE walls with different reinforcement configurations under footing loading—ScienceDirect. Geotext. Geomembr. 2026, 54, 1299–1309. [Google Scholar] [CrossRef] [Scilit]
- Yang, G.; Li, X.; Xu, P.; Wang, Z.; Wang, H.; Liu, W. Physical model study on dynamic behavior of PET geostrip-reinforced back-to-back MSE walls under bilateral cyclic loading—ScienceDirect. Soil Dyn. Earthq. Eng. 2026, 203, 110145. [Google Scholar] [CrossRef] [Scilit]
- Morsy, K.M.; Thakeb, H. Comparative evaluation of the environmental impacts of geosynthetic Mechanically Stabilized Earth walls. J. Clean. Prod. 2022, 374, 133912. [Google Scholar] [CrossRef] [Scilit]
- Pujadas-Gispert, E.; Sanjuan-Delmás, D.; Josa, A. Environmental analysis of building shallow foundations: The influence of prefabrication, typology, and structural design codes. J. Clean. Prod. 2018, 186, 407–417. [Google Scholar] [CrossRef] [Scilit]
- Abushama, K.; Hawkins, W.; Pelecanos, L.; Ibell, T. Optimizing the Embodied Carbon of Concrete, Timber, and Steel Piles with a Case Study|Springer Nature Link. In The 1st International Conference on Net-Zero Built Environment; Springer: Cham, Switzerland, 2025; pp. 899–911. [Google Scholar]
- Abushama, K.; Hawkins, W.; Pelecanos, L.; Ibell, T. Barriers and Enablers to the Decarbonisation of Deep Foundations in the UK: Insights from Geotechnical Industry Experts. Environ. Sustain. Indic. 2026, 32, 101521. [Google Scholar] [CrossRef] [Scilit]
- TB 10025-2019; Code for Design of Retaining Structures of Railway Earthworks. China Railway Publishing House: Beijing, China, 2019.
- Jiang, H.G.; Bian, X.C.; Xu, X. Full-scale physical model test on dynamic behavior of high-speed railway slab track subgrade under moving train loads. Chin. J. Geotech. Eng. 2014, 36, 354–362. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.