Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective Analysis
Abstract
1. Introduction
2. Materials and Methods
2.1. Patient Selection
2.2. Surgical Technique
2.3. Radiographic Protocol
2.4. Data Analysis
3. Results
3.1. Patient Demographics and Cohort Characteristics
3.2. Alignment
3.3. Accuracy of Implant Positioning
3.4. Inter-Surgeon Comparisons
3.5. Hip-Knee-Ankle Axis
3.6. Intra- and Inter-Observer Reliability of Measurements
3.7. Complications
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Acknowledgments
Conflicts of Interest
Abbreviations
| aHKA | arithmetic Hip–Knee–Ankle axis |
| BMI | body mass index |
| CR | cruciate retaining |
| CT | computed tomography |
| HKA | Hip–Knee–Ankle axis |
| LDFA | lateral distal femoral angle |
| MPTA | medial proximal tibial angle |
| PKA | partial knee arthroplasty |
| PS | posterior stabilized |
| RATKA | robotic-assisted total knee arthroplasty |
| TEA | trans-epicondylar axis |
| TKA | total knee arthroplasty |
| sTEA | surgical trans-epicondylar axis |
References
- Smith, A.F.; Eccles, C.J.; Bhimani, S.J.; Denehy, K.M.; Bhimani, R.B.; Smith, L.S.; Malkani, A.L. Improved Patient Satisfaction following Robotic-Assisted Total Knee Arthroplasty. J. Knee Surg. 2021, 34, 730–738. [Google Scholar] [CrossRef] [Scilit]
- Bourne, R.B.; Chesworth, B.M.; Davis, A.M.; Mahomed, N.N.; Charron, K.D.J. Patient satisfaction after total knee arthroplasty: Who is satisfied and who is not? Clin. Orthop. Relat. Res. 2010, 468, 57–63. [Google Scholar] [CrossRef] [Scilit]
- Singh, M.; Harary, J.; Schilling, P.L.; Moschetti, W.E. Patient Satisfaction Is Nearly 90% After Total Knee Arthroplasty; We Are Better Than We Were. J. Arthroplast. 2024, 40, 1521–1525. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kayani, B.; Konan, S.; Tahmassebi, J.; Pietrzak, J.R.T.; Haddad, F.S. Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: A prospective cohort study. Bone Jt. J. 2018, 100-B, 930–937. [Google Scholar] [CrossRef] [Scilit]
- Wong, W.K.; Sajak, A.A.B.; Chua, H.S. Real-world accuracy of robotic-assisted total knee arthroplasty and its impact on expedited recovery. J. Robot. Surg. 2024, 18, 309. [Google Scholar] [CrossRef] [Scilit]
- Mancino, F.; Cacciola, G.; Malahias, M.-A.; Filippis, R.D.; Marco, D.D.; Matteo, V.D.; Gu, A.; Sculco, P.K.; Maccauro, G.; Martino, I.D. What are the benefits of robotic-assisted total knee arthroplasty over conventional manual total knee arthroplasty? A systematic review of comparative studies. Orthop. Rev. 2020, 12, 8657. [Google Scholar] [CrossRef] [Scilit]
- Rossi, S.M.P.; Sangaletti, R.; Perticarini, L.; Terragnoli, F.; Benazzo, F. High accuracy of a new robotically assisted technique for total knee arthroplasty: An in vivo study. Knee Surg. Sports Traumatol. Arthrosc. 2023, 31, 1153–1161. [Google Scholar] [CrossRef] [Scilit]
- Kayani, B.; Konan, S.; Pietrzak, J.R.T.; Haddad, F.S. Iatrogenic Bone and Soft Tissue Trauma in Robotic-Arm Assisted Total Knee Arthroplasty Compared with Conventional Jig-Based Total Knee Arthroplasty: A Prospective Cohort Study and Validation of a New Classification System. J. Arthroplast. 2018, 33, 2496–2501. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Khlopas, A.; Sodhi, N.; Sultan, A.A.; Chughtai, M.; Molloy, R.M.; Mont, M.A. Robotic Arm-Assisted Total Knee Arthroplasty. J. Arthroplast. 2018, 33, 2002–2006. [Google Scholar] [CrossRef] [Scilit]
- Zhang, J.; Ndou, W.S.; Ng, N.; Gaston, P.; Simpson, P.M.; Macpherson, G.J.; Patton, J.T.; Clement, N.D. Robotic-arm assisted total knee arthroplasty is associated with improved accuracy and patient reported outcomes: A systematic review and meta-analysis. Knee Surg. Sports Traumatol. Arthrosc. 2022, 30, 2677–2695. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Song, E.-K.; Seon, J.-K.; Yim, J.-H.; Netravali, N.A.; Bargar, W.L. Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin. Orthop. Relat. Res. 2013, 471, 118–126. [Google Scholar] [CrossRef] [Scilit]
- Mancino, F.; Rossi, S.M.P.; Sangaletti, R.; Caredda, M.; Terragnoli, F.; Benazzo, F. Increased accuracy in component positioning using an image-less robotic arm system in primary total knee arthroplasty: A retrospective study. Arch. Orthop. Trauma Surg. 2024, 144, 393–404. [Google Scholar] [CrossRef] [Scilit]
- Mahoney, O.; Kinsey, T.; Sodhi, N.; Mont, M.A.; Chen, A.F.; Orozco, F.; Hozack, W. Improved Component Placement Accuracy with Robotic-Arm Assisted Total Knee Arthroplasty. J. Knee Surg. 2022, 35, 337–344. [Google Scholar] [CrossRef] [Scilit]
- Zaidi, F.; Goplen, C.M.; Bolam, S.M.; Monk, A.P. Accuracy and Outcomes of a Novel Cut-Block Positioning Robotic-Arm Assisted System for Total Knee Arthroplasty: A Systematic Review and Meta-Analysis. Arthroplast. Today 2024, 29, 101451. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Kenanidis, E.; Paparoidamis, G.; Milonakis, N.; Potoupnis, M.; Tsiridis, E. Comparative outcomes between a new robotically assisted and a manual technique for total knee arthroplasty in patients with osteoarthritis: A prospective matched comparative cohort study. Eur. J. Orthop. Surg. Traumatol. 2023, 33, 1231–1236. [Google Scholar] [CrossRef] [Scilit]
- Batailler, C.; Hannouche, D.; Benazzo, F.; Parratte, S. Concepts and techniques of a new robotically assisted technique for total knee arthroplasty: The ROSA knee system. Arch. Orthop. Trauma Surg. 2021, 141, 2049–2058. [Google Scholar] [CrossRef] [Scilit]
- Shin, C.; Crovetti, C.; Huo, E.; Lionberger, D. Unsatisfactory accuracy of recent robotic assisting system ROSA for total knee arthroplasty. J. Exp. Orthop. 2022, 9, 82. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Hasegawa, M.; Tone, S.; Naito, Y.; Sudo, A. Comparison of accuracy and early outcomes in robotic total knee arthroplasty using NAVIO and ROSA. Sci. Rep. 2024, 14, 3192. [Google Scholar] [CrossRef] [Scilit]
- Parratte, S.; Price, A.J.; Jeys, L.M.; Jackson, W.F.; Clarke, H.D. Accuracy of a New Robotically Assisted Technique for Total Knee Arthroplasty: A Cadaveric Study. J. Arthroplast. 2019, 34, 2799–2803. [Google Scholar] [CrossRef] [Scilit]
- Mulpur, P.; Desai, K.B.; Mahajan, A.; Masilamani, A.B.S.; Hippalgaonkar, K.; Reddy, A.V.G. Radiological Evaluation of the Phenotype of Indian Osteoarthritic Knees based on the Coronal Plane Alignment of the Knee Classification (CPAK). Indian J. Orthop. 2022, 56, 2066–2076. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- MacDessi, S.J.; Griffiths-Jones, W.; Harris, I.A.; Bellemans, J.; Chen, D.B. Coronal Plane Alignment of the Knee (CPAK) classification. Bone Jt. J. 2021, 103-B, 329–337. [Google Scholar] [CrossRef] [Scilit]
- Berger, R.A.; Rubash, H.E.; Seel, M.J.; Thompson, W.H.; Crossett, L.S. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin. Orthop. Relat. Res. 1993, 286, 40–47. [Google Scholar] [CrossRef] [Scilit]
- Adamska, O.; Modzelewski, K.; Szymczak, J.; Świderek, J.; Maciąg, B.; Czuchaj, P.; Poniatowska, M.; Wnuk, A. Robotic-Assisted Total Knee Arthroplasty Utilizing NAVIO, CORI Imageless Systems and Manual TKA Accurately Restore Femoral Rotational Alignment and Yield Satisfactory Clinical Outcomes: A Randomized Controlled Trial. Medicina 2023, 59, 236. [Google Scholar] [CrossRef] [Scilit]
- Cherches, M.; Coss, N.; Nguyen, K.; Halvorson, R.; Allahabadi, S.; Bini, S. No Correlation Between Clinical Outcomes and Changes in the Tibia-Metaphyseal Angle Following Total Knee Arthroplasty: A Retrospective Study. J. Arthroplast. 2022, 37, 1793–1798. [Google Scholar] [CrossRef] [Scilit]
- Clark, G.; Steer, R.; Wood, D. Functional alignment achieves a more balanced total knee arthroplasty than either mechanical alignment or kinematic alignment prior to soft tissue releases. Knee Surg. Sports Traumatol. Arthrosc. 2023, 31, 1420–1426. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Lustig, S.; Sappey-Marinier, E.; Fary, C.; Servien, E.; Parratte, S.; Batailler, C. Personalized alignment in total knee arthroplasty: Current concepts. SICOT J. 2021, 7, 19. [Google Scholar] [CrossRef] [Scilit]
- Bosco, F.; Rovere, G.; Burgio, C.; Bue, G.L.; Cobisi, C.D.; Via, R.G.; Lucenti, L.; Camarda, L. Accuracy and learning curve of imageless robotic-assisted total knee arthroplasty. J. Orthop. 2025, 66, 77–83. [Google Scholar] [CrossRef] [Scilit]
- Zhou, G.; Wang, X.; Geng, X.; Li, Z.; Tian, H. Comparison of Alignment Accuracy and Clinical Outcomes between a CT-Based, Saw Cutting Robotic System and a CT-Free, Jig-guided Robotic System for Total Knee Arthroplasty. Orthop. Surg. 2024, 16, 1168–1174. [Google Scholar] [CrossRef] [Scilit]
- Lei, K.; Liu, L.M.; Luo, J.M.; Ma, C.; Feng, Q.; Yang, L.; Guo, L. Could surgical transepicondylar axis be identified accurately in preoperative 3D planning for total knee arthroplasty? A reproducibility study based on 3D-CT. Arthroplasty 2022, 4, 46. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Paternostre, F.; Schwab, P.-E.; Thienpont, E. The difference between weight-bearing and non-weight-bearing alignment in patient-specific instrumentation planning. Knee Surg. Sports Traumatol. Arthrosc. 2014, 22, 674–679. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- MacDessi, S.J.; Griffiths-Jones, W.; Harris, I.A.; Bellemans, J.; Chen, D.B. The arithmetic HKA (aHKA) predicts the constitutional alignment of the arthritic knee compared to the normal contralateral knee: A matched-pairs radiographic study. Bone Jt. Open 2020, 1, 339–345. [Google Scholar] [CrossRef] [PubMed]



| Inclusion |
|---|
|
|
|
| Exclusion |
|
|
|
|
|
|
|
|
|
| Parameter | Paired Differences | Significance, p Value α | |||
|---|---|---|---|---|---|
| Mean, Degrees (°) | Std. Deviation, Degrees (°) | 95% Confidence Interval of Difference | |||
| Lower | Upper | ||||
| HKA | −1.66 | 2.09 | −2.09 | −1.23 | <0.001 |
| LDFA | −0.32 | 1.84 | −0.69 | 0.06 | 0.034 |
| MPTA | 0.84 | 1.17 | 0.60 | 1.08 | <0.001 |
| Rotational | 1.63 | 2.40 | 1.14 | 2.12 | <0.001 |
| Parameter | Mean ± SD, Degree (°) | Significance, p Value α | |||
|---|---|---|---|---|---|
| Surgeon A | Surgeon B | Surgeon C | Surgeon D | ||
| HKA | 0.007 | ||||
| Intra-op | 0.8 ± 1.7 | 0.5 ± 1.0 | 3.4 ± 2.4 | 1.0 ± 1.4 | |
| Post-op | 2.8 ± 2.6 | 2.5 ± 1.6 | 4.0 ± 3.4 | 3.8 ± 4.4 | |
| Difference | 2.0 ± 2.0 | 2.0 ± 1.5 | 0.6 ± 1.9 | 2.9 ± 3.1 | |
| LDFA | 0.265 | ||||
| Intra-op | 89.7 ± 1.6 | 89.4 ± 2.4 | 91.6 ± 2.0 | 90.5 ± 0.9 | |
| Post-op | 90.1 ± 1.5 | 90.5 ± 1.4 | 91.6 ± 2.5 | 90.4 ± 2.2 | |
| Difference | 0.3 ± 1.8 | 1.1 ± 2.1 | 0.0 ± 1.8 | 0.1 ± 1.5 | |
| MPTA | 0.604 | ||||
| Intra-op | 88.5 ± 1.3 | 89.9 ± 1.0 | 88.5 ± 1.7 | 88.6 ± 1.3 | |
| Post-op | 87.7 ± 1.3 | 88.7 ± 1.2 | 87.8 ± 2.0 | 87.7 ± 1.5 | |
| Difference | 0.8 ± 1.1 | 1.2 ± 0.8 | 0.8 ± 1.5 | 1.0 ± 0.7 | |
| Rotational | 0.007 | ||||
| Intra-op | 5.2 ± 3.7 | 2.1 ± 1.7 | 3.3 ± 2.6 | 2.8 ± 1.0 | |
| Post-op | 2.9 ± 2.1 | 2.3 ± 1.5 | 2.0 ± 1.2 | 1.6 ± 0.6 | |
| Difference | 2.3 ± 2.6 | 0.2 ± 1.0 | 1.3 ± 2.2 | 1.1 ± 1.3 | |
| Parameter | Rater | Intraclass Correlation Coefficient | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Intra-Observer | 95% Confidence Interval | Significance, p | Inter-Observer | 95% Confidence Interval | Significance, p | ||||
| Lower Bound | Upper Bound | Lower Bound | Upper Bound | ||||||
| LDFA | 1 | 0.984 | 0.972 | 0.992 | <0.001 | 0.991 | 0.982 | 0.995 | <0.001 |
| 2 | 0.993 | 0.986 | 0.996 | <0.001 | |||||
| 3 | 0.984 | 0.970 | 0.992 | <0.001 | |||||
| MPTA | 1 | 0.980 | 0.963 | 0.990 | <0.001 | 0.984 | 0.970 | 0.992 | <0.001 |
| 2 | 0.986 | 0.973 | 0.993 | <0.001 | |||||
| 3 | 0.978 | 0.959 | 0.989 | <0.001 | |||||
| ROT | 1 | 0.934 | 0.884 | 0.966 | <0.001 | 0.933 | 0.883 | 0.965 | <0.001 |
| 2 | 0.783 | 0.646 | 0.881 | <0.001 | |||||
| 3 | 0.929 | 0.875 | 0.963 | <0.001 | |||||
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Share and Cite
Wong, W.K.; Che-Kamaruddin, N.; Zulkhairi, S.Z.; Chong, S.Y.; Suhail, A.; George, S.V.N.; Ewe, T.W.; Chua, H.S. Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective Analysis. Life 2026, 16, 925. https://doi.org/10.3390/life16060925
Wong WK, Che-Kamaruddin N, Zulkhairi SZ, Chong SY, Suhail A, George SVN, Ewe TW, Chua HS. Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective Analysis. Life. 2026; 16(6):925. https://doi.org/10.3390/life16060925
Chicago/Turabian StyleWong, Wai Kit, Naim Che-Kamaruddin, Siti Zubaidah Zulkhairi, Shi Yao Chong, Abdullah Suhail, Suresh V Nainan George, Teong Wan Ewe, and Hwa Sen Chua. 2026. "Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective Analysis" Life 16, no. 6: 925. https://doi.org/10.3390/life16060925
APA StyleWong, W. K., Che-Kamaruddin, N., Zulkhairi, S. Z., Chong, S. Y., Suhail, A., George, S. V. N., Ewe, T. W., & Chua, H. S. (2026). Radiographic Accuracy and Consistency of Implant Placement Using the ROSA® Knee System in Robotic-Assisted Total Knee Arthroplasty: A Prospective Analysis. Life, 16(6), 925. https://doi.org/10.3390/life16060925

