A Tumbling Magnetic Microrobot System for Biomedical Applications
1
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA
2
School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA
3
Center for Cancer Research, Purdue University, West Lafayette, IN 47907, USA
*
Author to whom correspondence should be addressed.
†
These authors contributed equally to this work.
Micromachines 2020, 11(9), 861; https://doi.org/10.3390/mi11090861
Received: 10 July 2020 / Revised: 12 September 2020 / Accepted: 15 September 2020 / Published: 17 September 2020
(This article belongs to the Special Issue Magnetic Microrobots)
A microrobot system comprising an untethered tumbling magnetic microrobot, a two-degree-of-freedom rotating permanent magnet, and an ultrasound imaging system has been developed for in vitro and in vivo biomedical applications. The microrobot tumbles end-over-end in a net forward motion due to applied magnetic torque from the rotating magnet. By turning the rotational axis of the magnet, two-dimensional directional control is possible and the microrobot was steered along various trajectories, including a circular path and P-shaped path. The microrobot is capable of moving over the unstructured terrain within a murine colon in in vitro, in situ, and in vivo conditions, as well as a porcine colon in ex vivo conditions. High-frequency ultrasound imaging allows for real-time determination of the microrobot’s position while it is optically occluded by animal tissue. When coated with a fluorescein payload, the microrobot was shown to release the majority of the payload over a 1-h time period in phosphate-buffered saline. Cytotoxicity tests demonstrated that the microrobot’s constituent materials, SU-8 and polydimethylsiloxane (PDMS), did not show a statistically significant difference in toxicity to murine fibroblasts from the negative control, even when the materials were doped with magnetic neodymium microparticles. The microrobot system’s capabilities make it promising for targeted drug delivery and other in vivo biomedical applications.
View Full-Text
Keywords:
magnetic microrobots; biomedical microrobots; drug delivery
▼
Show Figures
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited
- Supplementary File 1:
ZIP-Document (ZIP, 36820 KiB)
MDPI and ACS Style
Niedert, E.E.; Bi, C.; Adam, G.; Lambert, E.; Solorio, L.; Goergen, C.J.; Cappelleri, D.J. A Tumbling Magnetic Microrobot System for Biomedical Applications. Micromachines 2020, 11, 861.
AMA Style
Niedert EE, Bi C, Adam G, Lambert E, Solorio L, Goergen CJ, Cappelleri DJ. A Tumbling Magnetic Microrobot System for Biomedical Applications. Micromachines. 2020; 11(9):861.
Chicago/Turabian StyleNiedert, Elizabeth E.; Bi, Chenghao; Adam, Georges; Lambert, Elly; Solorio, Luis; Goergen, Craig J.; Cappelleri, David J. 2020. "A Tumbling Magnetic Microrobot System for Biomedical Applications" Micromachines 11, no. 9: 861.
Find Other Styles
Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.
Search more from Scilit