Calibration of Event-Based Camera for High-Speed Observations of Lightning and Transient Luminous Events

,
,
,
,
,
,
,
and
1
Department of Space Research and Space Technology (DTU Space), Technical University of Denmark, 2800 Kongens Lyngby, Denmark
2
Instituto de Astrofísica de Andalucía (IAA), CSIC, 18008 Granada, Spain
3
Electromagnetic Compatibility Laboratory, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
4
Department of Applied Physics and Science Education, Eindhoven University of Technology (TU/e), 5612 AP Eindhoven, The Netherlands

Highlights

What are the main findings?
  • This study established quantitative relationships between the event camera’s digital bias settings and its physical response characteristics, including contrast threshold, refractory period, and low-pass filter corner frequency.
  • The calibrated low-pass filter response enables simulation of the camera response to transient optical signals and supports more accurate signal reconstruction.
  • Optimized bias settings were suggested for lightning and transient luminous event (TLE) observations based on the calibration results.
What are the implications of the main findings?
  • The calibration represents a first step toward quantitative reconstruction of fast optical signals measured by event cameras.
  • The results demonstrate the potential of event cameras for scientific high-speed observations of lightning and TLEs.
  • The study provides a necessary calibration framework for the quantitative use of event cameras in atmospheric remote sensing.

Abstract

Event-based vision sensors (EVSs) offer an innovative approach to optical sensing by responding solely to changes in photon flux with asynchronous pixels. This enables high-speed imaging with minimal data throughput and a large dynamical range > 120 dB. Despite their growing use in edge detection and the observation of Earth science phenomena such as lightning and transient luminous events (TLEs), optimizing EVS performance specifically for high-speed observations on microsecond timescales, where the photon flux is key, remains challenging. This is due to the unitless, non-intuitive nature of their bias settings, which drives the working principles of the sensor. In this study, we perform a comprehensive calibration of an event-based camera, focusing on three critical parameters: contrast thresholds, refractory period, and corner frequency of the inherent low-pass filter. Using a pre-calibrated LED source and newly developed event generation code, we establish physical relationships between these raw digital bias settings and the camera’s response characteristics. Our results show tunable ranges of 5–190% for on contrast thresholds, 5–65% for off contrast thresholds, 12–480 μs for refractory periods, and 1–11 kHz for corner frequencies. These calibrations provide the fundamental camera characteristics for accurate optical signal reconstruction and improved detection of fast transient phenomena. The approach is demonstrated on a Prophesee EVK4; however, the proposed calibration method can be applied to any EVS camera that employs similar hardware components and bias settings and thus provides a necessary framework for the quantitative use of EVS cameras in atmospheric remote sensing.

1. Introduction

Over the past 15 years, the development and use of event-based vision sensors (EVSs) have gained significant attention for remote sensing applications as a novel neuromorphic sensor that mimics the principles of retinal neurons. EVSs rely on asynchronous pixels using a special analog circuitry that acts as a temporal contrast sensor, transmitting data only in response to changes in the photon flux hitting the pixel [1,2].
Unlike traditional cameras, no frames or constant sampling rate are used. In turn, the individual pixel acts dynamically and individually based on its own received optical signal. When the variation in the logarithm of the photon flux exceeds a certain threshold value, the pixel will generate an event that is defined by four parameters [ x , y , p , t ] : the pixel coordinates ( x , y ) , the event polarity p: 1 for increased brightness (ON event) or 0 for decreased brightness (OFF event) and a timestamp t.
A standard frame-based camera operates with a simple pixel circuit, where photodiodes convert incoming photons to a charge that is measured, giving a photocurrent in each of the pixels. This principle applies to both CCD and CMOS sensors. CCD sensors have relatively limited pixel circuitry, whereas CMOS sensors use a slightly more advanced circuit where the photon is converted to a voltage on the pixel. In these cameras, settings such as ISO settings and shutter speed can be optimized for high-speed observations. All pixels are synchronized and output a full frame at the given frame rate.
The EVS technology is also based on CMOS sensors, but with more complex active pixel circuitry included. In simplified terms, each EVS pixel contains a photodiode similar to that of a frame-based sensor. The resulting photocurrent is subsequently passed through a logarithmic converter, where it is transformed into a logarithmic voltage signal, providing a large dynamic range. Afterwards the signal passes through a buffer stage, which can be modeled as a first-order low-pass filter that is characterized by its corner frequency. The signal then enters a differencing circuit that retains the baseline voltage established by the most recent event and continuously compares it with the incoming signal. This difference is evaluated by a comparator stage, and an event is triggered when the positive or negative relative change in brightness exceeds a predefined positive or negative threshold, respectively. Following an event, a reset mechanism temporarily inhibits the differencing circuit, after which a new baseline value is established—this time it is the refractory period. Finally, the digital readout logic converts the trigger into an event representation that is transmitted and saved [1,3]. The operations of the individual stages in the EVS can be controlled by adjusting the bias currents in different parts of the chip. This is conceptually comparable to modifying the operating parameters of a frame-based camera; however, the effects of these adjustments are not directly equivalent.
The performance of the EVS can be tuned by varying the so-called bias settings to control the camera behavior in different ways. In total, four tunable raw digital bias settings are accessible by the user [4], including those for the corner frequency of the low/high pass filter, a refractory period corresponding to a dead time for each pixel after an event, and the ON/OFF thresholds related to the generation of ON/OFF events [5]. These properties make the EVS capable of working with a high temporal resolution of 1–10 μs and a large dynamic range of > 120 dB , with a low data rate and low power consumption [2,6]. These capabilities, furthermore, make the EVS perfect for remote sensing purposes as their operational requirements are low, compared to conventional frame-based high-speed cameras.
Previous studies on EVSs have focused on using their high dynamic range and low data rate for applications such as autonomous vehicles, drones, motion detection, satellite tracking, and monitoring [7,8,9,10,11]. One can also note that the sparse, asynchronous nature of EVS data makes it well-suited to machine learning algorithms. Recently, additional efforts have been made to study natural phenomena in Earth sciences, including auroras, meteors, lightning, and Transient Luminous Events (TLEs) in the upper regions of the atmosphere above thunderstorms [12,13,14]. These studies highlight the potential of EVSs for high-speed optical observations from space, particularly for future satellite lightning mapping. Its high temporal resolution, wide dynamic range, and low data rate make it a promising technology for next-generation lightning imagers. However, it is crucial to understand the exact working principles of the camera and to fine-tune the individual bias settings. This allows for optimizing the camera settings for any given scenario.
Furthermore, standard calibration methods for frame-based cameras are not sufficient when calibrating an event camera. For frame-based cameras, this is usually done with a static source with known intensity. As the event camera requires changes in the photon flux, it is necessary to have a tunable calibration source where the light level is known both at the lowest and largest luminosities.
Other calibration work has focused mainly on optimizing quality metrics for the generated event streams [15]. However, our main interest is high-speed observations of electrical discharges in the atmosphere, such as lightning and TLEs, and related physical processes. They occur extremely fast on millisecond time scales, with some sub-processes even reaching microsecond time scales [16]. Thus, we focus on assessing the temporal resolution of the EVS and calibrating the most relevant bias settings, particularly the low-pass-filter corner frequency and the refractory period associated with the pixel dead time.
This paper is based on experimental data from a blinking pre-calibrated LED diode measured with a Prophesee EVK4 camera (LED Luxeon, 20 May 2026, https://www.luxeonstar.com/wp-content/uploads/documentation/ds68.pdf). This LED can be driven with rise times on the order of approximately 50 n s [17] and is thus sufficiently fast for the measurements presented in this paper. The LED is modulated only above its forward voltage, such that the emitted intensity is varied without switching the LED fully on and off during the measurements. The EVK4 camera is based on the Sony IMX636 sensor co-developed with Prophesee (IMX636, 20 May 2026, https://www.sony-semicon.com/files/62/flyer_industry/IMX636-AAMR-Flyer.pdf). The sensor consists of 1280 × 720 pixels of size 4.86 µm × 4.86 µm, offering a dynamic range of 120 dB and a maximum event rate 1.06 Geps (Giga-events per second) with low power consumption. Additionally, it also offers the possibility of choosing a region of interest (ROI), which consequently makes the other pixels inactive.

2. Bias Setting Parameters of Event-Based Camera

The event camera data consist of an event stream of ( x , y , p , t ) tuples, where ( x , y ) indicates the position of the pixel that generated the event, p represents the polarity, with “1” for an ON event and “0” for an OFF event, and t is the timestamp of the event in μs. The operating principles of the camera are controlled by bias currents on the different parts of the chip, these are altered with bias settings. The four bias settings of interest for high-speed observations are the ON/OFF threshold, the corner frequency affecting the low-pass filter, and the refractory period that introduces a dead time for each individual pixel. An overview of the bias settings for the EVK4 camera with their individual range and effects is shown in Table 1.
Table 1. Bias settings for EVK4. The bias values appear as signed digital integer offsets relative to their factory-calibrated default values, defined as zero. Although these offsets do not have a direct physical interpretation, they modify the internal bias currents and thereby influence the sensor response. The performance of the camera is further described in Section 3.
A simulated example showing the effects of different bias settings on a single pixel is presented in Figure 1. We applied two different low-pass filter settings with corner frequencies ( f c ) of 1 kHz and 10 kHz to demonstrate the effect of the low-pass filter. The thresholding for ON/OFF event generation is applied to the filtered signals. Therefore, a threshold of 5 % does not directly correspond to a 5 % change in photon flux but to the corresponding change in the low-pass-filtered signal. The effect of the refractory period is also shown in the figure; here the refractory period is set to 200 μs. During the dead time, event generation is suppressed; however, the pixel continues to sample the analog signal internally, such that the signal level at the end of the refractory period defines the new reference light level for subsequent event generation. This is illustrated by the purple steps, which demonstrate the amount of signal lost during the refractory period. It should be noted that, although the duration of the refractory period remains the same, the amount of signal loss also depends on the signal slope during the dead time. Consequently, the steeper signal (black) experiences a larger loss than the flatter signal (blue).
Figure 1. Simulated response of a single pixel to an incident optical signal (yellow). The low-pass filtered signals are based on a first-order infinite impulse response (IIR) low-pass filter [18] and are shown for two corner frequencies: f c = 10 kHz (black) and f c =  1 kHz (blue). A refractory period of 200 µs (magenta), also known as the pixel dead time, follows each event, during which no new events can be generated. The purple points indicate that the refractory period has ended, and this value is the new reference level for the pixel to generate subsequent events. Green and red markers indicate the times when ON and OFF events are triggered, respectively. The contrast threshold is set to 5% for both ON and OFF events.
Therefore, accurate estimation of the variation in photon flux from event stream data requires not only knowledge of the contrast threshold settings but also the corner frequency f c and the refractory period. These aspects will be discussed in detail in the following sections.

3. Calibration Parameters for Event-Based Cameras

3.1. Threshold

EVS cameras have independent and asynchronous pixels that respond to changes in the logarithm of the brightness signal [1]. An “on” event is triggered when the magnitude of the logarithmic brightness level has increased by more than an “on” threshold for an individual pixel u k = ( x k , y k ) at a time t k . To investigate the thresholds, we assume very slow changes in light levels, such that we can ignore the effects of the refractory period and the low-pass filter. In this case, the event generation follows the increasing log photocurrent L reaching the threshold:
Δ L ( u k , t k + Δ t ) = L ( u k , t k + Δ t ) − L ( u k , t k ) ,
where L is the log photocurrent L = l o g ( I ) , and Δ t denotes the time required for the light level to cross the threshold after the most recent event at t k . For a slowly varying signal, Δ t ≫ t refr , where t refr is the refractory period. An “on” (“off”) event denotes a photocurrent increase (decrease) reaching the corresponding “on” (“off”) threshold. The thresholds Θ of EVK4 camera are defined with three bias settings: bias_diff, bias_diff_on and bias_diff_off. In general, it follows,
Θ on = α ln I on I diff ,
Θ off = α ln I off I diff .
where I diff is a bias current set with the bias_diff setting, which is recommended by the manufacturer to remain constant and was therefore kept at its default value of 0 throughout this work. Both I on and I off are bias currents, considered as variables, and are set with the bias settings bias_diff_on and bias_diff_off, respectively. α is a factor that depends on the electrical characteristics of the sensor, and Θ off is negative as I off is smaller than I diff . In general, the relationship between the threshold, the number of measured events, and change in intensity is given by
I max I min = ( e Θ o n ) κ on max ,
I min I max = ( e Θ off ) κ off max ,
where κ on max and κ off max are the maximum number of generated ON/OFF events in a single pixel measured by the EVK4 camera when the signal increases/decreases. I max / I min is the relative change of light intensity from the maximum to the minimum. For small values of Θ , the threshold can be interpreted as a percentage change in illumination because ln ( 1 + Θ ) ≈ Θ when Θ ≪ 1 . We therefore define the thresholds in terms of the direct relative change in intensity and introduce,
θ on = e Θ on − 1 ,
θ off = e Θ off − 1 .
Note that θ off is negative in the same manner as Θ off . In our calibration, our objective is to determine how bias setting changes in bias_diff_on and bias_diff_off affect the percentage change θ in the light level. We first simulate a “star field” with stars of known magnitudes for the EVK4 camera by varying the input current of a Spacecraft Optical Ground Support Equipment (SOGSE provided by Terma A/S) based on a calibrated (amber) LED [19]. We use a 1 Hz triangular wave such that the influence of the refractory period and the low-pass filter is negligible and can therefore be omitted. We then determine the ratio of the maximum to minimum Intensity, I max / I min , from the triangular wave using a HAMAMATSU photomultiplier (Hamamatsu photomultiplier tube, 20 May 2026, https://www.hamamatsu.com/content/dam/hamamatsu-photonics/sites/documents/99_SALES_LIBRARY/etd/H13126_TPMO1116E.pdf).
The percentage changes θ on and θ off in the detected light level can be estimated from the number of events accumulated from the minimum to the maximum intensity and from the maximum to the minimum intensity, respectively [20,21]:
I max I min = ( 1 + θ o n ) κ on max ,
I min I max = ( 1 + θ off ) κ off max ,
θ on and θ off are the relative changes of light intensity to create a single event. As our main goal is to observe transient phenomena such as lightning, we are interested in balanced bias settings that produce similar numbers of ON and OFF events in response to comparable increases and decreases in light intensity. Since the triangular wave is symmetric, the same intensity ratio is applied to the on and off responses. However, the on and off thresholds are controlled by different bias settings, and the same triangular wave can therefore produce different numbers of ON and OFF events even when the two bias settings are set to the same value.
The aim is therefore to tune the two bias settings such that the sensor responds symmetrically to the triangular wave input. For each measured value of bias_diff_on, we determine a corresponding value of bias_diff_off such that
κ on max ≈ κ off max .
Although the number of ON and OFF events are approximately equal under these conditions, the corresponding relative thresholds are not equal in magnitude. An increase from I min to I max is measured relative to I min , whereas the corresponding decrease from I max to I min is measured relative to I max . For approximately equal numbers of ON and OFF events,
1 + θ off ≈ 1 1 + θ on ,
and therefore,
θ off ≈ θ on 1 + θ on .
For small threshold values, this reduces to
θ off ≈ θ on .

3.2. Refractory Period

The refractory period of the camera, also known as the dead time of an individual pixel, is an amount of time after the production of an event where the pixel will not produce new events. Furthermore, the new reference light level is only set after the refractory period, meaning that changes are essentially lost during this time. It is controlled by the bias setting of bias_refr. In general, the time between two events on a given pixel is Δ t = t σ + t refr , where t σ is the time it takes for the optical signal to pass a threshold level above the reference value at time t refr , and t refr is the refractory period after the latest generated event. The refractory period can be estimated by changing the signal sufficiently fast for t σ ≪ t refr , from which an upper limit of the dead time can be estimated by finding the smallest observed Δ t in the distribution of received events.
This is done by sending a 100 kHz sine wave to the LED with a function generator, lowering the thresholds to a minimum level of less than 5 % , and ensuring a negligible t σ , such that the minimum measured value of Δ t provides an approximate estimate of the refractory period for each refractory-period bias setting.

3.3. Low-Pass Filter

The generation of events is affected by the low-pass filtering. This effect is controlled by the bandwidth bias setting of bias_fo. It is often used to remove flickering and noise from the scene, but we are interested in its effect on high-speed observations and investigate how changing bias_fo affects the corner frequency f c of the low-pass filter [18].
For this purpose, we use an event generation model based on a first-order infinite impulse response (IIR) low-pass filter with a constant corner frequency f c [18] by taking both the ON/OFF thresholds and the refractory period into account. The filtered signal received at the single-pixel level will follow,
L f ( n ) = L f ( n − 1 ) + d t τ [ L ( n ) − L f ( n − 1 ) ] ,
where τ is the time constant, defined by the corner frequency as τ = 1 2 π f c , n being the n th event registered and d t is defined as the time difference between the ( n − 1 ) th and n th events. L is the original log (photocurrent) from Equation (1) and L f is the filtered signal. The effects of different corner frequencies applied to the same original signal L is demonstrated in Figure 1. The corner frequency f c can be determined by generating sine waves for the LED source using a function generator with varying input frequencies. By applying different bias_fo and changing the input frequency of the LED signal, the number of generated ON/OFF events for a defined region of pixels is recorded to evaluate the corner frequency which follows Equation (14).
In order to determine f c , we simulate the pixel response to LED sine wave signals using the same frequencies as those used in the measurements, taking into account both the refractory period used for the measurements and the estimated pixel threshold mismatch. This enables evaluating the simulated corner frequency that minimizes the difference between the simulated and measured results for different bias_fo settings.

4. Results

The calibration of the EVS requires three distinct measurements, which can allow for reconstruction of the optical signal for high-speed observation. This includes a threshold estimation, an estimation of the refractory period, and a measurement of the corner frequency associated with the low pass filtering.

4.1. Threshold Calibration

The threshold was estimated using a pre-calibrated SOGSE provided by TERMA. This equipment simulates a star field of which the intensity is slowly altered by changing the voltage level on the LED with a triangular wave between 3 V and 5 V at a frequency of 1 Hz.
Assuming that the illumination of the “star” at applied voltages of 3 V and 5 V corresponds to Intensities of I min and I max , respectively, Equations (8) and (9) can be used to determine the thresholds θ on and θ off from the measured peak numbers of ON and OFF events, κ on max and κ off max , respectively.
We measured the thresholds after adjusting bias_diff_on and bias_diff_off accordingly to obtain a similar number of ON and OFF events at a refractory period of 50 μs. The results of this matching process are shown in Figure 2A. Figure 2B presents the calibrated curve of the ON and OFF thresholds as a function of the bias_diff_on setting. The inset illustrates an example fit for the threshold settings used to determine the peak event value.
Figure 2. (A) Relationship between bias_diff_on and bias_diff_off that produces similar event counts at a refractory period of 50 µs. Blue dots show the values used for threshold estimation, while the orange line show an exponential fit, enabling the user to match arbitrary ON and OFF bias settings. (B) On (blue) and off (red) thresholds as a function of bias_diff_on. The results are based on a region of 100 × 100 pixels including the brightest star in the field of view. The error bars are derived from the fitting results. The inset shows a logarithmic Gaussian (log-Gauss) fit at bias_diff_on = − 20 as denoted by the arrow. This is used to estimate the peak event count at different bias settings. The x-axis indicates pixel indices.

4.2. Refractory Period Calibration

As described in the previous section, we measured the refractory period by finding the shortest time between consecutive events illuminated by a star field modulated with a 100 kHz sine-wave voltage, and the contrast thresholds are set to < 5 % based on the measurement shown in Figure 2B. The results are shown in Figure 3A, which gives the refractory period as a function of the bias setting. Results obtained from the tabulated values in the Prophesee API function are also shown in the figure for comparison (Metavision Software (v5.3.1), 20 May 2026, https://docs.prophesee.ai/stable/index.html). Both curves show similar behavior, with a logarithmic scaling of the refractory period vs. the bias_refr setting. From the measurement we are, however, able to reach slightly lower refractory periods at the largest bias settings. This refractory period can be tuned approximately 12–480 μs by applying different bias_refr settings. Figure 3B shows two examples of refractory period measurements. The top panel shows the fastest setting where Δ t ≈ t refr = 12 µs. The bottom panel shows the slowest possible setting where Δ t ≈ t refr = 480 µs.
Figure 3. (A) The refractory periods as a function of bias_refr settings. The factory calibrated results from the Prophesee API function (orange) are shown in the figure for comparison. The errorbars are estimated from the timestamp resolution of the EVK4. (B) Measurements of refractory periods for two different bias_refr settings. The top panel shows the fastest setting, where the refractory period is found to be 12 µs, whereas the bottom panel show the slowest setting with a refractory period of 480 µs.

4.3. Corner Frequency Calibration

The calibration of the corner frequency aims to determine the value of f c in Equation (14), which is associated with the bias setting bias_fo. The frequency of the sine-wave modulation applied to the LED source was varied over a wide range (1 Hz, 5 Hz, 10 Hz, 50 Hz, 100 Hz, 500 Hz, 1 kHz, 2 kHz, 3 kHz, 4 kHz, 5 kHz, 6 kHz, 7 kHz, 8 kHz, 9 kHz, 10 kHz, 20 kHz, 30 kHz, 40 kHz, and 50 kHz) for nine different settings of bias_fo. For these measurements, the ON/OFF thresholds were set according to Figure 2, with θ on = 12 % and θ off = 11 % , corresponding to similar event rates for ON and OFF events. As the period of the fastest signals was on the order of 100 μ s , the refractory period was set to its minimum value (∼ 12 μ s ) to minimize its influence on the measurements. For a region of 100 × 100 pixels, the total number of ON and OFF events registered per cycle was estimated and are shown in Figure 4.
Figure 4. Measurements of the corner frequency at different bias_fo settings for on (A) and off (B) events. As the frequency of the applied sine wave through the LED increases, the number of registered events decreases due to the low-pass filtering effect.
We can see from the figure that the high-frequency components have been filtered out by the low-pass filter of the event camera. Notably, for bias_fo > 0 the measurement curves have a similar feature just below 10 kHz where the measurements overlap. This effect is due to the limitation imposed by the refractory period.
To estimate the corner frequency f c , we simulated the generation of events using an event generation code based on Equations (1)–(14). We simulated the event response at the single-pixel level to a sine signal. Figure 5 shows a simulation of a single ideal pixel, with a set threshold and no refractory period for different simulated corner frequencies. The amplitude of the simulated sine wave is set such that the simulated event count/cycle matches the measured values at 100 Hz. The simulations of this ideal pixel are compared with the measurements for a low-pass filter bias setting bias_fo = 10 (black curve). The result shows that the simulations do not fully capture the measurements.
Figure 5. Simulation of a single perfect pixel with no threshold mismatch and no effect from the refractory period with different f c against the measurement result (black) at bias_fo = 10. The horizontal dashed black line indicates the value where only a single ON event is present per sine wave. For a single perfect pixel this is the lowest possible simulation value.
To explain and correct this discrepancy, we incorporated the refractory period and the effect of threshold mismatch in the model. The latter was modeled by simulating the average pixel response over 500 pixels with slightly different thresholds. To do so, the threshold for each pixel was sampled from a Gaussian distribution whose parameters were determined by matching the simulated event distribution to the measured distribution, as shown in Figure 6A,B. The Gaussian distributions that best match the measured event distributions are characterized by θ on = 12 % and θ off = 11 % , with a random Gaussian error of σ = 2 % . We then resimulated the average response of 500 pixels using a refractory period of 12 μs and the previously determined threshold mismatch. Figure 7 presents a flowchart of the event-generation algorithm.
Figure 6. Histogram of simulated (A) and measured (B) pixel response for a 100 Hz sine wave. These show the distribution of ON events for a single cycle, highlighting that there is threshold mismatch between pixels—leading to a distribution of event counts in different pixels. The distribution for the simulated pixels (A) match the measurement (B) when a random Gaussian error of σ = 2 % is included for each pixel in the simulation.
Figure 7. Flowchart of the event generation procedure, including the refractory period and pixel-to-pixel threshold mismatch. Events are simulated over the interval t = 0 to t = t end , and the procedure is repeated for each simulated f c .
The simulation was performed over a range of corner frequencies and accounts for both the refractory period and randomly sampled threshold mismatches. The results are presented in Figure 8A,B. The comparison was made for ON and OFF events at bias_fo = 10 using different corner frequencies. It is noted that the corner frequency of 9000 Hz best matches the measurement when using bias_fo = 10 for both ON and OFF events. Figure 8C,D shows the residuals by calculating the difference between the measured and simulated values. As both ON and OFF measurements rely on the same bias_fo setting, we chose the best simulated value as the corner frequency that matches both measurements. However, accurately matching the ON events is particularly important for high-speed imaging of lightning processes, which is the primary application considered in this work. Based on the results shown in the figure, we therefore select f c = 9 kHz as the value that provides the best overall agreement across the investigated frequency range. Furthermore, the residuals indicate good agreement across the entire frequency range, with only small deviations from a perfect match.
Figure 8. (A,B) Simulation of an area of pixels with threshold mismatch and the refractory period of 12 µs at different f c against the measurement result (black) at bias_fo = 10 for ON and OFF events, respectively. Best match is at a corner frequency of 9000 Hz for both ON and OFF events. (C,D) Residuals when comparing measured values with simulation, for ON and OFF events, respectively.
This method allows the corner frequency to be determined for all bias_fo settings. Figure 9 shows the inferred relationship between bias_fo and the low-pass filter corner frequency f c obtained by matching measurements at bias_fo = [ − 30 , − 20 , − 10 , 0 , 10 , 20 , 30 , 40 , 50 ] with the corresponding simulations. The change in the bias_fo setting follows an S-shaped curve: it starts slowly (below the default value of 0), then rises rapidly (from 0 to 30), and finally stays nearly constant as it approaches approximately 11 kHz.
Figure 9. bias_fo vs. corner frequencies. The curve is obtained by finding the simulation frequencies with R 2 > 0.95 between measured and simulated results for a given bias_fo, with the same frequency for both ON and OFF measurements. The errorbars are estimated from the distance between the simulated values used in each of the estimations.

5. Discussion

5.1. Optimization

For optimizing bias settings towards high-speed operations, one can note from Figure 1, that the number of events produced on the filtered signal with a corner frequency of 1 kHz (blue) and 10 kHz (black) is the same. It appears surprising as their amplitudes are, respectively, 62% and 95% of the original signal, corresponding to a slew rate of 0.89 and 1.35 ms − 1 . This illustrates the effect of the refractory period, clarifying that the event generation process is occurring outside the dead time. As the signal with the larger corner frequency is less impacted by the low pass filter, the refractory spans a larger portion of the signal, thus resulting in a larger signal loss. The amount of signal loss in this example can be estimated as 33% and 57%, respectively, which is correlated with the slew rate. This suggests that relatively slow low-pass and refractory period settings can still be effective for detecting fast transient signals, such as those produced by lightning and TLEs. Finally, it should be noted that the low pass filtering does not cut off high-speed signals. Thus, the EVS can observe signals that are faster than the corner frequency, however, interpretation of the result requires better understanding of the bias settings. Furthermore, the amplitude of the filtered signal depends on the corner frequency. For a strongly filtered signal, the contrast thresholds should therefore be lowered to ensure event generation.
This interpretation along with the calibrated physical parameters for the bias settings allows for a practical guide on observing different high-speed electrical phenomena. This is further illustrated in Table 2, which summarizes typical time constants of high-speed electrical phenomena relevant to this study [22,23]. The table also provides suggested physical values for the bias settings that may be suitable for these phenomena. The thresholds are specified in terms of θ on , and the corresponding value of θ off can then be selected based on the results shown in Figure 2. In most cases a low refractory period is preferred; however, it can be increased for the slower phenomena to reduce data size. For the fastest and faint phenomena, where the tunable range of f c gives a time constant that is slower than the phenomenon, it is recommended to use low θ on / θ off threshold settings, as event generation operates after a low-pass filtering of the logarithm of the illuminance, meaning that the amplitude observed by the EVS is less than the amplitude of the actual optical signal. Finally, the low-pass filter settings suggested here are chosen such that the time constant τ = 1 2 π f c
τ ≪ t o b s ,
where t o b s is the time constant associated with the observed phenomena. Note that the lowest possible value is τ ≈ 12   μ s , which means that Equation (15) cannot be fully satisfied for the fastest phenomena. Furthermore, the suggested values are for cases where the rise time and general time constants matter most. In other cases, the magnitude of the received signal may be more important, and a lower ( f c ) may be beneficial to avoid losing larger portions of the signal during the refractory period. Finally, faster bias settings with low refractory period and large f c , will increase the number of background noise events. Therefore, it is not recommended to use the fastest bias settings regardless of the observed phenomenon. Note that these are general recommendations, and factors such as the optical system, observation distance, and the actual relative change in light intensity produced by the phenomena may vary. The bias settings may require further fine-tuning for each specific observation scenario.
Table 2. Typical time constants for different physical phenomena and recommended bias settings. The bias_fo required to reach the suggested corner frequencies can vary if the steady-state illumination of the process is much brighter than that of the physical phenomena considered here.
Our results also give a comprehensive understanding of the low pass filtering and brightness thresholding, which can serve as a basis for reconstructing the optical signal from the event-based camera by reversing the equations that govern the generation of events with the correct parameters. However, additional measurements validating the calculations are needed to support this.
Another consideration for the low-pass filtering process is that its effect depends on the illumination of the sensor. This is influenced by both the intensity of the light source and the distance to it. The corner frequency increases linearly with increasing illumination [24]. As the voltage of the LED is varied only between 3 V and 5 V, the effects of changes in illumination are neglected. However, it should be noted that the corner frequencies would differ when observing brighter scenes [25]. However, the effect of varying the bias_fo setting remains comparable to the reported results, although with an offset due to the linear increase in corner frequencies.
All examples listed in Table 2 are assumed to occur under low-background-intensity conditions. The experiments presented here are designed to emulate these events. At higher initial background illumination levels, a lower bias_fo setting may produce a similar or higher operational corner frequency f c . Therefore, for a given bias_fo setting, the results presented in this study represent a worst-case scenario for the corner frequency.

5.2. Bandwidth Saturation

Another point we want to discuss here is the saturation that limits the maximal event rate. While the sensor does not saturate similarly to a frame-based camera due to overexposure, it has a maximum feasible event rate. For the EVK4, this limitation is 1.06 Geps (Giga events pr second) across the entire sensor, or roughly 1000 events μ s − 1 . To mitigate this, an event rate controller filter in the final stage of the data processing circuit can be used to reduce the event rate by randomly discarding events that exceed the maximum allowable rate, although this comes at the cost of reduced signal quality [6]. Selecting a region of interest (ROI) may also help mitigate saturation; however, this reduces the field of view. Our work gives the tools to optimize the bias settings for signal quality and accuracy while staying below the saturation limit of the sensor.

5.3. Sensor Variation

Although the measurements were obtained using a single Prophesee EVK4 camera, they were performed across the sensor array and therefore account for pixel-to-pixel variability. Small device-to-device differences may still arise from fabrication tolerances; however, the use of factory-calibrated relative bias settings is expected to minimize their effect on the reproducibility of the results (Prophesee Biases, 11 May 2026, https://docs.prophesee.ai/stable/hw/manuals/biases.html). The absolute bias values can be read using Prophesee software, for the camera presented here the absolute values are: bias_fo = 88, bias_diff_on = 99, bias_diff_off = 55 and bias_refr = 20. Readers are encouraged to compare these values with those of their own EVK4 cameras, as absolute factory-calibrated default values may vary slightly between devices. For other EVS cameras based on the same IMX636 sensor, such as the IDS uEye XCP-E (IDS Event camera, 20 May 2026, https://en.ids-imaging.com/store/ue-39b0xcp-e.html), SilkyEvCam HD (SilkyCam, 20 May 2026, https://centuryarks.com/en/silkyevcam-hd/) and Lucid Triton2 EVS (Lucid Triton, 20 May 2026, https://thinklucid.com/triton2-evs/?srsltid=AfmBOopua3OwM_mxjjQxmtc39DzJDe8Sftz2iB1jIMKIUWeIaU6aRG38), the results may also be applicable since the bias definitions are consistent with those used in the Prophesee software. Nevertheless, users are advised to reproduce a subset of the calibration points to reduce uncertainties associated with possible inter-device variations. For other types of event-based vision sensors, such as DAVIS or DVS cameras (InivatiON event cameras, 20 May 2026 https://inivation.com/solutions/cameras/), the proposed calibration method can be reproduced, as they employ similar hardware components that can be controlled through corresponding bias settings.

6. Conclusions

In this work, we have characterized the EVK4 event-based camera by evaluating the ranges and physical significance of four key bias parameters that control its performance for high-speed detection. Our results show (1) the correspondence with the ON/OFF threshold bias setting and the contrast threshold. For θ o n this can be varied from 5% to 190%, and for θ o f f the range is 5% to 65% corresponding to a similar range in terms of events generated; (2) the correspondence between the low-pass filter bias setting and the corner frequency of the low-pass filter varies between 1 kHz and 11 kHz; (3) the correspondence between the dead-time bias setting and the pixel refractory period varies between 12 µs and 480 µs. The results of the measurements are summarized in Table 3. Note that the full operating range reported in Table 3 is not tested for the ON and OFF threshold bias. The range of the ON threshold is limited on the lower end to restrict the range to having similar of ON and OFF events. For the high end, the threshold is limited to about 200% which is high enough for most applications and only reflects the limitation of our LED. By providing a clear mapping between the bias settings and the camera performance, we allow the reader to tune and find the best compromise when observing a given physical phenomenon, especially fast processes which require high-speed observations.
Table 3. The operating range for different bias settings.

Author Contributions

Conceptualization, D.L., O.C., T.N., A.L. and N.P.; methodology, D.L., O.C., N.P. and T.L.; software, N.P. and T.L.; validation, D.L., O.C. and F.R.; formal analysis, N.P.; investigation, N.P. and T.L.; resources, J.S. and F.J.G.-V.; data curation, T.L. and N.P.; writing—original draft preparation, N.P.; writing—review and editing, D.L., O.C., F.R., F.J.G.-V. and A.L.; visualization, N.P., D.L. and O.C.; supervision, O.C., D.L. and F.R.; project administration, D.L.; funding acquisition, D.L. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Danish Council for Independent Research for a Danmarks Frie Forskningsfond (DFF) Sapere Aude Grant with Agreement 3120-00088B.

Data Availability Statement

The data that support the findings of this study are openly available at the following URL/DOI: https://doi.org/10.5281/zenodo.20374228.

Conflicts of Interest

The authors declare no conflicts of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

Abbreviations

The following abbreviations are used in this manuscript:
EVSEvent-Based Vision Sensor
TLETransient Luminous Events

References

  1. Lichtsteiner, P.; Posch, C.; Delbruck, T. A 128 × 128 120 dB 15 μs Latency Asynchronous Temporal Contrast Vision Sensor. IEEE J.-Solid-State Circuits 2008, 43, 566–576. [Google Scholar] [CrossRef] [Scilit]
  2. Gallego, G.; Delbruck, T.; Orchard, G.; Bartolozzi, C.; Taba, B.; Censi, A.; Leutenegger, S.; Davison, A.J.; Conradt, J.; Daniilidis, K.; et al. Event-Based Vision: A Survey. IEEE Trans. Pattern Anal. Mach. Intell. 2022, 44, 154–180. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  3. Furmonas, J.; Liobe, J.; Barzdenas, V. Analytical Review of Event-Based Camera Depth Estimation Methods and Systems. Sensors 2022, 22, 1201. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  4. Dilmaghani, M.S.; Shariff, W.; Ryan, C.; Lemley, J.; Corcoran, P. Control and evaluation of event cameras output sharpness via bias. In Proceedings of the Fifteenth International Conference on Machine Vision (ICMV 2022); SPIE: Bellingham, WA, USA, 2022. [Google Scholar]
  5. McMahon-Crabtree, P.N.; Kulesza, L.; McReynolds, B.J.; O’Keefe, D.S.; Puttur, A.; Maestas, D.; Morath, C.P.; McHarg, M.G. Event-based camera refractory period characterization and initial clock drift evaluation. In Proceedings of the Unconventional Imaging, Sensing, and Adaptive Optics 2023; Dolne, J.J., Spencer, M.F., Bose-Pillai, S.R., Eds.; International Society for Optics and Photonics; SPIE: Bellingham, WA, USA, 2023; Volume 12693, pp. 253–273. [Google Scholar] [CrossRef] [Scilit]
  6. Prophesee. EVK4 Evaluation Kit. 2023. Available online: https://www.prophesee.ai/event-camera-evk4/ (accessed on 20 May 2026).
  7. Gehrig, D.; Scaramuzza, D. Low-latency automotive vision with event cameras. Nature 2024, 629, 1034–1040. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  8. Jolley, A.; Afshar, S.; Cohen, G.; Lazarus Pahlavani, R.; Lambert, A. Neuromorphic Sensor Event-Rate Monitoring for Satellite Characterization. J. Spacecr. Rocket. 2023, 60, 753–764. [Google Scholar] [CrossRef] [Scilit]
  9. Ralph, N.O.; Marcireau, A.; Afshar, S.; Tothill, N.; van Schaik, A.; Cohen, G. Astrometric calibration and source characterisation of the latest generation neuromorphic event-based cameras for space imaging. Astrodynamics 2023, 7, 415–443. [Google Scholar] [CrossRef] [Scilit]
  10. Shariff, W.; Dilmaghani, M.S.; Kielty, P.; Moustafa, M.; Lemley, J.; Corcoran, P. Event Cameras in Automotive Sensing: A Review. IEEE Access 2024, 12, 51275–51306. [Google Scholar] [CrossRef] [Scilit]
  11. Ni, Z.; Ieng, S.H.; Posch, C.; Régnier, S.; Benosman, R. Visual Tracking Using Neuromorphic Asynchronous Event-Based Cameras. Neural Comput. 2015, 27, 925–953. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. McHarg, M.G.; Jones, I.R.; Wilcox, Z.; Balthazor, R.L.; Marcireau, A.; Cohen, G. Falcon Neuro space-based observations of lightning using event-based sensors. Front. Remote. Sens. 2024, 5, 1436898. [Google Scholar] [CrossRef] [Scilit]
  13. Chanrion, O.; Pedersen, N.; Yair, Y.; Stendel, M.; Li, D.; Stokholm, A.; Neubert, T. THOR-DAVIS: A Neuromorphic Camera for Thunderstorm Observation from the International Space Station (ISS). In Proceedings of the American Geophysical Union Fall Meeting, San Franciso, CA, USA, 11–15 December 2023; AGU Fall Meeting Abstracts. Volume 2023, p. AE01-08. [Google Scholar]
  14. Smith, B.; McHarg, M.G.; da Silva, C.L.; Sonnenfeld, R.G.; Koile, J.; Leal, A.F.R.; Jones, I.R. Sprite Durations Measured with a Neuromorphic Sensor. Geophys. Res. Lett. 2024, 51, e2024GL109353. [Google Scholar] [CrossRef] [Scilit]
  15. Ziegler, A.; Joseph, D.; Gossard, T.; Moldovan, E.; Zell, A. BiasBench: A Reproducible Benchmark for Tuning the Biases of Event Cameras. In Proceedings of the 2025 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW), Nashville, TN, USA, 11–12 June 2025; pp. 4994–5003. [Google Scholar]
  16. Füllekrug, M.; Mareev, E.A.; Rycroft, M.J. Sprites, Elves and Intense Lightning Discharges; Springer Science and Business Media: Berlin/Heidelberg, Germany, 2006; Volume 225. [Google Scholar]
  17. Burton, A.; Bentley, E.; Le Minh, H.; Ghassemlooy, Z.; Aslam, N.; Liaw, S.K. Experimental demonstration of a 10BASE-T Ethernet visible light communications system using white phosphor light-emitting diodes. IET Circuits Devices Syst. 2014, 8, 322–330. [Google Scholar] [CrossRef] [Scilit]
  18. McReynolds, B.J.; Graca, R.; O’Keefe, D.; Oliver, R.; Balthazor, R.; George, N.; McHarg, M. Modeling and decoding event-based sensor lightning response. In Proceedings of the Unconventional Imaging, Sensing, and Adaptive Optics 2023; Dolne, J.J., Spencer, M.F., Bose-Pillai, S.R., Eds.; International Society for Optics and Photonics, SPIE: Bellingham, WA, USA, 2023; Volume 12693, pp. 335–352. [Google Scholar] [CrossRef] [Scilit]
  19. Lumileds. LUXEON Rebel Color Line. 2025. Available online: https://www.luxeonstar.com/wp-content/uploads/documentation/ds68.pdf (accessed on 20 May 2026).
  20. Nozaki, Y.; Delbruck, T. Temperature and Parasitic Photocurrent Effects in Dynamic Vision Sensors. IEEE Trans. Electron Devices 2017, 64, 3239–3245. [Google Scholar] [CrossRef] [Scilit]
  21. Delbruck, T.; Graca, R.; Paluch, M. Feedback control of event cameras. In Proceedings of the 2021 IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW), Los Alamitos, CA, USA, 19–25 June 2021; pp. 1324–1332. [Google Scholar] [CrossRef] [Scilit]
  22. Davidson, G.T. Pitch-angle diffusion and the origin of temporal and spatial structures in morningside aurorae. Space Sci. Rev. 1990, 53, 45–82. [Google Scholar] [CrossRef] [Scilit]
  23. Dwyer, J.R.; Uman, M.A. The physics of lightning. Phys. Rep. 2014, 534, 147–241. [Google Scholar] [CrossRef] [Scilit]
  24. McReynolds, B.; Graca, R.; Delbruck, T. Experimental methods to predict dynamic vision sensor event camera performance. Opt. Eng. 2022, 61, 074103. [Google Scholar] [CrossRef] [Scilit]
  25. McReynolds, B.; Graca, R.; Oliver, R.; Nishiguchi, M.; Delbruck, T. Demystifying Event-based Sensor Biasing to Optimize Signal to Noise for Space Domain Awareness. In Proceedings of the Advanced Maui Optical and Space Surveillance (AMOS) Technologies Conference, Wailea, HI, USA, 19–22 September 2023; Ryan, S., Ed.; p. 142. [Google Scholar]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics