16 September 2026

20 Pages

Gas Plume Detection from Infrared Hyperspectral Remote Sensing Data Based on Deep Learning Algorithms

,
,
and
1
State Key Laboratory of Chemistry for NBC Hazards Protection, Beijing 102205, China
2
Key Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
*
Author to whom correspondence should be addressed.

Highlights

What are the main findings?
  • A compact 1D-CNN was developed for the pixelwise identification of co-path multicomponent gas signatures and the extraction of binary detection regions from infrared hyperspectral spectra.
  • The model achieved high classification accuracy on controlled simulated spectra and a favorable Precision–Recall balance on fixed-platform field measurements relative to four conventional detectors.
What are the implications of the main findings?
  • Under the tested conditions, the 1D spectral model provided a compact end-to-end alternative to the evaluated multi-stage detection methods.
  • The results constitute a fixed-elevated-platform field proof of concept; extension to mobile or airborne operation requires separate validation under platform motion, vibration, and changing viewing geometry.

Abstract

Infrared hyperspectral remote sensing is effective for chemical gas detection because gas molecules exhibit characteristic absorption features in the mid- and long-wave infrared region. This study considers coexisting gas components along a common line of sight rather than geometrically distinct spatial plumes. We propose a compact spectral one-dimensional convolutional neural network (1D-CNN) for pixelwise gas species identification and the extraction of binary detection regions directly from 121-band spectra. Across five independently simulated NETD conditions and cross-noise train–test evaluations, the model maintained consistently strong classification performance over the examined noise range. On the measured scenes, the proposed model was compared with four traditional detectors and an adapted spectral Transformer baseline, showing a favorable and comparatively consistent Precision–Recall balance across the four target gases. These results support a fixed-platform field proof of concept, but do not constitute airborne-platform, edge deployment, quantitative concentration retrieval, or broad cross-site validation.

1. Introduction

Infrared hyperspectral remote sensing has become an important technique for detecting and identifying gas plumes because it can acquire both spectral and spatial information. The physical basis of this technique is that gas molecules absorb infrared radiation at specific wavelengths when the photon energy matches molecular vibrational or rotational energy transitions, producing characteristic absorption features. These species-dependent spectral signatures provide an important basis for chemical identification [1]. In particular, the mid- and long-wave infrared region, approximately 3–14 μm, corresponds to fundamental vibrational transitions and usually exhibits stronger absorption than the overtone and combination bands in the short-wave infrared region, making it highly suitable for gas plume detection and identification [2].
Infrared hyperspectral techniques have therefore been widely used in applications such as industrial emission monitoring, environmental pollution assessment, and chemical contaminant surveillance. However, measured hyperspectral radiance is jointly affected by atmospheric transmission, background radiation, sensor response, and gas absorption or emission. As a result, gas plume detection from measured data is challenging, especially when the plume signal is weak, the background is complex, or multiple gas species coexist in the same scene. Accurate gas species identification and gas plume spatial extent extraction therefore require robust data processing methods that can effectively distinguish gas-related spectral variations from background interference [3,4,5,6].
Existing gas detection methods are still largely dominated by matched filtering and statistical analysis. Representative approaches include spectral matching, matched-filter detectors, adaptive matched filtering, target-constrained detectors, and statistical feature extraction [7,8,9,10,11,12]. These methods have clear physical interpretations and relatively low computational cost, but commonly depend on predefined target spectra or background statistics. Their assumptions can become less reliable when several gas components coexist along one line of sight, their absorption bands overlap, or measured background radiance departs from the assumed distribution.
Dimensionality reduction and optimization methods, including principal component analysis, independent component analysis, support vector machines, residual modeling, denoising, and nonlinear fitting, have also been used to suppress background interference [13,14,15,16]. Their effectiveness still depends on feature design, spectral priors, or statistical assumptions. The systematic evaluation of co-path multicomponent gas signatures in measured infrared hyperspectral data therefore remains limited.
Deep learning provides an alternative because it can learn nonlinear representations from high-dimensional spectra. Convolutional and attention-based models have shown adaptability to spectral distortion, noise, and background interference [17,18,19,20]. Nevertheless, the available studies often address different sensing geometries, single-gas tasks, or laboratory data [21,22,23]; thus, their transferability to the fixed-platform, co-path mixture setting considered here remains to be established.
The specific problem addressed here is the pixelwise identification of coexisting gas components in controlled simulations and fixed-platform field measurements. The task is challenging when absorption structures overlap and gas-related spectral variations are weak relative to the background. The study does not involve modeling geometric overlap among multiple spatially independent plumes.
To address this scoped problem, we propose and evaluate a compact 1D-CNN that operates directly on spectral sequences. Two convolutional layers learn local relationships among neighboring bands, and a progressively compressed fully connected module performs classification. The study first evaluates the proposed network on controlled simulations, including a five-level NETD analysis, and then assesses it on fixed-platform measured scenes against traditional and recent comparison methods. The contribution is therefore an end-to-end 1D-CNN method and a measured-data field proof of concept, not a demonstration of airborne operation or edge-device readiness.

2. Basic Physical Model

As shown in Figure 1, when additional chemical contaminants are present along the line connecting the target and the sensor, infrared radiative transfer is affected by both absorption and emission from the contaminants, and the contribution of the contaminants is accumulated in the radiance entering the sensor aperture. The at-aperture radiance of a pixel containing chemical contaminants can be expressed as
L o n λ k = L o n , 1 λ k + L o n , 2 λ k + L o n , 3 λ k + L p λ k
where the terms L o n , L o n , 1 , L o n , 2 , L o n , 3 , L p , and λ k denote the radiance entering the sensor aperture, the surface-emitted component, the surface-reflected component, the contaminant-emitted component, the atmospheric path radiance, and the center wavelength of a given band, respectively.
Figure 1. Radiative-transfer schematic for a co-path multicomponent gas mixture. The illustrated gas layer represents the combined transmittance of coexisting components along one line of sight; it is not a geometric model of multiple spatially separated plumes. The arrows indicate the direction of light propagation, the dashed lines delineate the sensor’s field of view, and the dash-dot-dot line represents the optical axis of the sensor.
The surface-emitted component can be written as
L o n , 1 λ k = B T s , λ k ε λ k t o n λ k t λ k
where the terms B , ε , t o n , and t denote the blackbody radiance corresponding to the equivalent surface temperature, surface emissivity, contaminant transmittance, and atmospheric transmittance, respectively.
The relationship between contaminant transmittance and contaminant concentration can be expressed as Equation (3).
t o n λ k = e − c g a s a g a s λ k
For a single component, the terms in Equation (3) denote the path-integrated concentration (ppm·m) and the wavelength-dependent absorption coefficient, respectively.
For a co-path mixture containing N gas components, the total transmittance is modeled as τ m i x ( λ k ) = e x p ( − ∑ i = 1 N c i a i ( λ k ) ) , where c i and a i are the path-integrated concentration and absorption coefficient of component i . This expression assumes that the components share the same line of sight and are represented by a common effective temperature. Equation (3) is recovered when N = 1. The formulation does not describe geometric overlap among spatially separated plume layers.
The contaminant emission component can be expressed as
L o n , 2 λ k = 1 − ε λ k ∫ − π π L a λ k t o n λ k , θ s + B T g a s , λ k 1 − t o n λ k , θ s d θ s t o n λ k t λ k
where the terms L a , B T g a s , λ k , and T g a s denote the downwelling atmospheric radiance, the blackbody radiance corresponding to the equivalent temperature of the contaminant, and the temperature of the contaminant, respectively. t o n λ k , θ s denotes the contaminant transmittance at an incident angle of θ s .
The at-sensor radiance of a contaminated pixel can also be expressed as
L o n , 3 λ k = B T g a s , λ k 1 − t o n λ k t λ k

3. Method

As shown in Figure 2, the overall network architecture consists of three core components: an input preprocessing layer; a feature extraction module composed of two convolutional layers and one pooling layer; and a classification decision module composed of fully connected layers with Dropout regularization. The design of each layer and the associated parameter settings are intended to ensure effective extraction of one-dimensional infrared hyperspectral sequence features while maintaining computational efficiency.
Figure 2. Architecture of the compact 1D-CNN evaluated in this study.
During initialization, the input spectral length (input_length), number of classes (n_classes), convolution kernel size (kernel_size), and pooling kernel size (pool_size) are specified. The input is reshaped to a single-channel spectral sequence, processed by two convolutional layers and one pooling layer, flattened, and passed to a three-layer fully connected classifier with Dropout. The output layer produces logits for cross-entropy loss. This configuration is compact relative to larger spectral–spatial networks, but hardware-specific edge deployment is not evaluated in this study.
Because the four gases generate 16 mutually exclusive presence/absence combinations, the task was formulated as a 16-class single-label classification problem rather than a four-output multilabel problem. Each spectrum was assigned one integer class corresponding to the four-bit presence/absence vector for SF6, C2F6, CHF3, and C3F8. Accordingly, the final layer produces 16 class logits, and the network is optimized using cross-entropy loss with an integer class label. During inference, the predicted class is decoded into four gas-specific binary indicators to generate the corresponding detection masks.
Feature extraction uses two one-dimensional convolutional layers and one max pooling layer to capture local absorption structures. The first convolution maps one input channel to 96 channels with a default kernel size of input_length/9. Max pooling uses a kernel and stride of 2. The second convolution maps 96 channels to 128 channels using the same kernel size. These settings define the evaluated architecture and are not claimed to be globally optimal.
Each convolutional layer is followed by a ReLU activation function. The pooling layer is only applied after the output of conv1, thereby forming a feature extraction sequence in which convolution, activation, pooling, convolution, and activation are performed in succession. This arrangement allows the network to first capture low-level spectral features, suppress redundancy and reduce dimensionality, and finally extract more abstract contaminant-related representations.
The flatten layer has no configurable parameters. Its role is to transform the three-dimensional feature tensor produced by the convolutional module—with dimensions B × 128 × L3, where L3 denotes the sequence length output by conv2—into a two-dimensional vector of size B × features_size, where features_size = 128 × L3. This step provides the necessary transition from feature extraction to classification by converting the convolutional output into a one-dimensional input format suitable for the subsequent fully connected layers.
The classification decision module adopts a design based on three fully connected layers together with Dropout regularization, progressively compressing the feature dimension and producing the final classification result. The first fully connected layer (fc1) takes features_size as the input dimension and outputs fc1_out_dim = int(features_size × 0.2), which corresponds to 20% of the flattened feature dimension, followed by a ReLU activation function. A Dropout layer is then inserted after fc1, with parameter p = 0.5, meaning that 50% of the neurons are randomly deactivated. The second fully connected layer (fc2) takes fc1_out_dim as the input dimension and outputs fc2_out_dim = int(fc1_out_dim × 0.5), corresponding to 50% of the output dimension of fc1, again followed by a ReLU activation. The third fully connected layer (fc3) takes fc2_out_dim as input and outputs n_classes, corresponding to the number of target classes. No activation function is applied in this final layer, and the output is directly given as logits.
A gradually increasing channel-number design is adopted in the convolutional part of the network. The first convolutional layer outputs 96 channels for basic feature extraction, mainly capturing fundamental spectral absorption and reflection characteristics. The second convolutional layer increases the output to 128 channels in order to mine more abstract features and enhance the distinction among different chemical contaminants. This moderate increase in channel number allows the network to cover a broader range of spectral feature dimensions without excessive expansion, such as increasing directly to 256 or 512 channels, thereby balancing feature expression capacity and computational efficiency.
The fully connected module progressively compresses the flattened feature vector: fc1 uses 20% of features_size, and fc2 uses 50% of the fc1 output before mapping to n_classes. This gradual reduction was selected to limit the dominant fully connected parameter count while avoiding a direct jump from the flattened representation to the class logits.
The three fully connected layers implement progressive feature abstraction and classification. Because no dedicated ablation was performed, the architecture is not attributed a specific percentage improvement over a single-layer classifier.
Dropout with p = 0.5 is applied after fc1 as a regularizer, and ReLU is used in the hidden layers to introduce nonlinearity and support stable gradient propagation. No activation is applied to the final logits because the cross-entropy loss internally performs the required normalization. No numerical gain is assigned to Dropout or ReLU in the absence of an ablation experiment.

4. Data

4.1. Simulated Data

Simulated spectra are used for model training and internal validation (Figure 3). The GasTest training set uses a background–target decoupling strategy rather than a fully realistic scene replication strategy. Gas-free spectra retain surface-emissivity variability, whereas gas-positive spectra use unit emissivity so that their variation is governed primarily by gas absorption. The selected training configuration is summarized in Table 1. Its intended scope is controlled spectral discrimination and background rejection; it does not reproduce the full variability of real surfaces or sensor artifacts.
Figure 3. Examples of the simulated spectra: (a) gas-free; (b) SF6; (c) C2F6; (d) CHF3; (e) C3F8; (f) SF6 + C2F6; (g) SF6 + CHF3; (h) SF6 + C3F8; (i) C2F6 + CHF3; (j) C2F6 + C3F8; (k) CHF3 + C3F8; (l) SF6 + C2F6 + CHF3; (m) SF6 + C2F6 + C3F8; (n) SF6 + CHF3 + C3F8; (o) C2F6 + CHF3 + C3F8; and (p) SF6 + C2F6 + CHF3 + C3F8. Each colored curve is one simulated sample; color is used only to distinguish curves and does not encode a single temperature, emissivity, or concentration level.
Table 1. Parameter settings for the GasTest simulation datasets.
Each GasTest dataset contains 95 background cases and 84 = 4096 concentration vectors, yielding 95 × 4096 = 389,120 spectra per NETD dataset and 1,945,600 spectra across the five NETD datasets. A zero concentration denotes the absence of that component; the four gases therefore generate 16 presence/absence labels. All datasets use the tropical atmospheric model, a surface temperature of 314.70 K, and air and gas temperatures of 299.70 K. The main 0.05 K file and four additional noise levels (0.10, 0.20, 0.40, and 0.50 K) were used for the robustness analysis. For the four added levels, the existing simulator recalculated the radiances from the surface-emissivity library, spectral response functions, atmospheric parameters, and four-gas absorption coefficients rather than perturbing an existing cube. Full 181-band radiances spanning 8.0–12.5 µm were retained, and zero-based bands 8:129 (121 bands; 8.2–11.2 µm) were used for model training and evaluation.
Gas-free samples retain 95 surface-emissivity spectra and therefore act as a hard-background library. For every concentration vector containing at least one gas, emissivity is set to unity to suppress surface-specific spectral structure and isolate the mixed-gas absorption response. This asymmetric assignment is intentional: when a realistic emissivity structure is superimposed on both classes, emissivity troughs near gas response bands can enter the gas-positive feature manifold and increase background false alarms. The adopted design instead presents these structured surface spectra as negative examples and asks the classifier to respond to the isolated gas component.
This choice trades physical scene completeness for a background rejection prior. It reduces the risk that surface-emissivity structure alone is labeled as gas, but it may under-represent interactions between weak gas signatures and previously unseen surfaces. We therefore do not interpret the near-ceiling simulation results as proof of background invariance. Generalization is assessed separately by the direct, uncalibrated transfer of the simulation-trained model to fixed-platform measured scenes containing real background variability; the remaining limits for new surfaces and sites are stated in the Section 6.
To isolate NETD while holding the remaining simulation factors constant, the simulator used the same paired standardized Gaussian field scaled separately to 0.05, 0.10, 0.20, 0.40, and 0.50 K. The proposed 1D-CNN was trained independently at each noise level using the same fixed split of 36,966 training, 1946 validation, and 350,208 test spectra; AdamW optimization; a batch size of 100; 100 epochs; and three random seeds (2026, 2027, and 2028). The existing 0.05 K checkpoints followed this protocol, and new checkpoints were trained for the other four levels. Each trained 1D-CNN was then evaluated on all five noise-level test sets, giving 5 × 5 train–test cells and 75 seed-level evaluations. No input normalization, threshold adjustment, or postprocessing was applied. Cell values are reported as the mean ± sample SD across three seeds; row, column, and overall averages are equal-weight means of the underlying seed-level runs.

4.2. Measured Data

The ATHIS instrument was operated from a fixed elevated position approximately 34 m above ground; it was not mounted on an aircraft or unmanned platform in this experiment. The gas-release location was at an elevation of approximately 16 m. The horizontal and slant ranges from the instrument to the release area were approximately 130 m and 131.2 m, respectively. The nominal ground sampling interval was approximately 0.13 m, and the 40° field of view covered about 95.5 m at the target range. Both single-species and mixed releases were included. Because the archived figure and records supplied with this manuscript do not establish a near-far-near scan trajectory, that unsupported description has been removed.
The instrument was ATHIS, an airborne-capable thermal infrared hyperspectral imaging system developed by the Shanghai Institute of Technical Physics, Chinese Academy of Sciences (Shanghai, China) [24]. In the present study, however, ATHIS was used on the fixed platform described above. It comprises three thermal infrared hyperspectral cameras whose fields of view are combined to provide a 40° observation field; each camera has an optical field of view of approximately 14°. Three RT spectrometers are housed in a 100 K cryogenic enclosure, and the system includes radiometric calibration. The main technical specifications of ATHIS are presented in Table 2. The average sensitivity is below 0.2 K at 300 K [24]. The instrument’s airborne design capability should not be interpreted as flight validation of the present experiment.
Table 2. Technical specifications of ATHIS.
The fixed-platform field experiment was conducted on 12 May 2023 by the Institute of Chemical Defense and the Shanghai Institute of Technical Physics, Chinese Academy of Sciences. Acquired records included hyperspectral and blackbody calibration imagery, target and background spectra, meteorological observations, target temperatures, and geographic locations. After radiometric preprocessing, the measured spectra shown in Figure 4 were obtained. SF6, C2F6, CHF3, and C3F8 were used as safe surrogates because they are nonflammable and non-toxic and exhibit distinct long-wave infrared absorption features.
Figure 4. Fixed-elevated-platform field experiment and measured data: (a) fixed instrument position, observed test scene, and gas release area; (b) false-color composite of the measured hyperspectral cube; and (c) representative pixel spectrum. The instrument and release area were separated horizontally by approximately 130 m. In panel (c), the blue, green, and red vertical lines mark the bands used for the corresponding false-color channels and coincide with representative absorption features near 9.4, 9.9, and 10.6 μm; they are spectral markers rather than gas concentration indicators.
For the measured-scene evaluation, four gas-specific binary reference masks (SF6-T, C2F6-T, CHF3-1-T, and C3F8-1-T) were delineated in ENVI (v5.3) using a decision-tree-assisted and manually reviewed procedure. ENVI was only used to identify initial candidate regions; the final masks were not defined by a single universal threshold. The known release region was first localized from the controlled experimental layout and the co-registered false-color image, after which candidate pixels were identified from gas-specific spectral responses around the characteristic absorption features. The screening thresholds were adjusted interactively for each gas scene and served as candidate selection aids rather than final labeling rules. During manual review, isolated background responses, spatially discontinuous pixels, and responses inconsistent with the known release geometry were removed, whereas connected responses associated with the release region were retained. The finalized masks were fixed before scoring and applied consistently to all evaluated methods. Because the numerical settings used during the original interactive screening were not archived, this preliminary step cannot be retrospectively reconstructed exactly from fixed threshold values. This constraint concerns the traceability of the initial candidate selection, not the definition or consistent use of the finalized reference masks. The masks are treated as expert-reviewed binary presence/absence reference annotations rather than independently measured gas concentration fields; the reference regions used for scoring.

5. Results

5.1. Network Training Results

The proposed 1D-CNN was trained on the fixed GasTest split using raw 121-band spectra, AdamW optimization, a batch size of 100, 100 epochs, and three independent seeds. The model contains approximately 6.24 million parameters and produces a 24.960 MB state-dictionary checkpoint. As shown in Figure 5, Training loss decreased rapidly, and validation macro-F1 reached its maximum within the first two epochs across the three seeds. This rapid convergence is an observation of the fixed simulation split and does not by itself exclude overfitting or sensitivity to distribution shift.
Figure 5. Representative training curves of the proposed 1D-CNN: (a) cost function; (b) accuracy. Matched-noise performance across the five NETD levels is summarized in Table 3.
Table 3 shows that the proposed 1D-CNN maintained consistently strong matched-noise performance across the examined NETD range, with the clearest decline occurring at 0.50 K. The cross-noise evaluations similarly indicated that performance was most sensitive to the highest test NETD: training at higher NETD improved the average transfer across test noise levels, whereas models trained at 0.05 K showed a measurable penalty when tested at 0.50 K. Overall performance remained high, but these results are limited to spectrum-level random holdout within the fixed simulated grid and to the tested Gaussian-equivalent noise model; they do not establish generalization to unseen concentration combinations or structured sensor artifacts.
Table 3. Matched-noise accuracy and macro-F1 of the proposed 1D-CNN at five NETD levels (mean across three training seeds).

5.2. Binary Gas Presence Results from Measured Data

The measured data evaluation included SF6, C2F6, CHF3, and C3F8. The results are presented in the following order: the traditional RA, ASD, LMF, and BMF methods; an adapted one-dimensional spectral Transformer baseline (ST-1D) inspired by the neighboring-band group-wise spectral embedding concept of SpectralFormer [22]; and the proposed 1D-CNN. ST-1D uses only the single-pixel spectral vector and does not incorporate spatial neighborhood information. All methods were assessed on the same fixed-platform measured scenes using the same binary reference masks. Table 4 reports accuracy, Precision, Recall, FPR, and F1, and Figure 6, Figure 7, Figure 8 and Figure 9 show the corresponding binary detection maps. Because gas-positive pixels occupy a small fraction of each image, accuracy is interpreted together with Precision, Recall, FPR, and F1. These comparisons assess binary presence/absence detection and do not constitute concentration retrieval; the metrics quantify agreement with the reference annotations rather than absolute accuracy against an independently measured concentration field.
Table 4. Binary gas detection results for four traditional methods, ST-1D, and the proposed 1D-CNN on the fixed-platform measured dataset. All metrics quantify agreement with the binary reference masks described in Section 4.2 rather than absolute accuracy against independently measured concentration fields.
Figure 6. Binary SF6 detection comparison: (a) binary reference mask; (b) RA; (c) ASD; (d) LMF; (e) BMF; (f) ST-1D; and (g) proposed 1D-CNN. Panel (a) shows the ENVI decision-tree-assisted, manually reviewed binary reference mask. Red overlays in panels (b–g) denote binary detections, not gas concentration. The red overlays in the panels indicate binary gas detections rather than gas concentrations. The other colors result from the false-color composite and visualize spatial variations in gas dispersion. The same applies to the figures below.
Figure 7. Binary C2F6 detection comparison: (a) binary reference mask; (b) RA; (c) ASD; (d) LMF; (e) BMF; (f) ST-1D; and (g) proposed 1D-CNN. Panel (a) shows the ENVI decision-tree-assisted, manually reviewed binary reference mask. Red overlays in panels (b–g) denote binary detections, not gas concentration.
Figure 8. Binary CHF3 detection comparison: (a) binary reference mask; (b) RA; (c) ASD; (d) LMF; (e) BMF; (f) ST-1D; and (g) proposed 1D-CNN. Panel (a) shows the ENVI decision-tree-assisted, manually reviewed binary reference mask. Red overlays in panels (b–g) denote binary detections, not gas concentration.
Figure 9. Binary C3F8 detection comparison: (a) binary reference mask; (b) RA; (c) ASD; (d) LMF; (e) BMF; (f) ST-1D; and (g) proposed 1D-CNN. Panel (a) shows the ENVI decision-tree-assisted, manually reviewed binary reference mask. Red overlays in panels (b–g) denote binary detections, not gas concentration.
For reproducibility, ST-1D processed each raw 121-band single-pixel spectrum as overlapping one-dimensional spectral patches with a patch size of 11 and a stride of 5. It used a 64-dimensional embedding, three Transformer encoder layers, four attention heads, an MLP ratio of 2.0, a dropout rate of 0.1, and a 16-class output head, giving 103,952 trainable parameters. The same fixed GasTest split used for the proposed 1D-CNN was adopted, comprising 36,966 training, 1946 validation, and 350,208 test spectra. ST-1D was trained for 100 epochs with a batch size of 100 using AdamW, an initial learning rate of 0.001, a weight decay of 0.0001, and a ReduceLROnPlateau scheduler with a factor of 0.5 and a patience of eight epochs. The best checkpoint was selected by validation macro-F1, with validation loss used to break ties. The seed-2026 checkpoint was used to generate the ST-1D results reported in Table 4 and Figure 6, Figure 7, Figure 8 and Figure 9.
ST-1D yielded F1-scores of 21.00%, 40.62%, 85.47%, and 4.20% for SF6, C2F6, CHF3, and C3F8, respectively, while the traditional methods produced gas-dependent Precision–Recall trade-offs. The proposed 1D-CNN, presented after these comparison methods in Table 4 and Figure 6, Figure 7, Figure 8 and Figure 9, achieved the highest F1-score for all four gases and maintained a more balanced response across the four scenes. These results describe the reported fixed measured-data comparison and are not evidence of universal superiority across sensors, sites, or acquisition geometries.
The conventional detectors remain attractive when the background is smooth and a reliable target spectrum is available because they are simple and computationally efficient. In the present data, their Precision–Recall trade-off varied substantially across gases. A plausible reason for the CNN’s more consistent balance is that one-dimensional convolutions jointly encode neighboring bands and can represent broader or overlapping absorption structures instead of relying on a single response peak. This interpretation is limited to the tested gas mixtures and background conditions.

6. Discussion

Within the scope of the reported experiments, the compact 1D-CNN provided a useful end-to-end spectral classifier for co-path multicomponent gas signatures. Its local convolutions can combine information from adjacent bands, which offers a plausible mechanism for separating broader and overlapping absorption structures. The measured-data results show a more consistent Precision–Recall balance than the four evaluated conventional detectors, but do not confirm that deep learning is necessary in every long-wave infrared scene. Matched-filter and statistical methods may remain preferable when backgrounds are smooth, target spectra are well known, and minimum computation is the primary requirement.
Several limitations constrain interpretation. First, the background–target decoupling design intentionally emphasizes the rejection of structured surface backgrounds but does not exhaustively represent gas-over-surface interactions. Direct transfer to the present measured scenes partially tests this choice, but broader surface types and sites are required before claiming background invariance. Second, the field data were collected from a fixed elevated platform; aircraft or UAV motion, vibration, attitude change, and rapidly varying viewing geometry were not evaluated. Third, the reference masks are decision-tree-assisted, manually reviewed presence/absence annotations rather than independently measured concentration truth; the reported field metrics should therefore be interpreted as reference mask agreement. Fourth, the model contains 6.2389 million parameters, and its edge-device deployment cost was not evaluated. Fifth, the direct transfer test contains a pronounced simulation-to-measurement scale and domain shift; it evaluates robustness without field calibration, not the maximum performance obtainable after a documented calibration procedure. Sixth, the five-level NETD analysis varies independent Gaussian-equivalent radiance noise while holding other simulator inputs fixed; it does not cover spectrally correlated noise, calibration drift, bad pixels, or previously unseen structured backgrounds.
The numerical settings used during the original interactive ENVI candidate screening were not archived. Consequently, it is only this preliminary screening step that cannot be replayed exactly from fixed threshold values; the finalized binary reference masks shown in Figure 6, Figure 7, Figure 8 and Figure 9 were held fixed and applied consistently across all methods.
The measured-data comparison places the proposed 1D-CNN alongside four traditional detectors and a recent deep learning method. The proposed network achieved the highest F1-score for all four gases in the reported scenes, supporting a more consistent Precision–Recall balance under this fixed-platform evaluation. This result is limited to the measured data and reference masks used here and does not establish universal architectural superiority. The five-level simulation and retraining analysis separately shows high gas-level F1 and Recall through 0.50 K, while the cross-noise evaluation reveals measurable degradation when low-noise training is applied to the highest-noise test data. Training at 0.50 K gave the highest equal-weight cross-test average, suggesting that matched high-noise training can improve tolerance to Gaussian-equivalent noise. The most direct remaining steps are validation under correlated sensor artifacts and more diverse surface backgrounds and sites, together with batch-size-one benchmarking on an actual edge device.

7. Conclusions

In this study, a compact 1D-CNN for the pixelwise identification of co-path multicomponent gas signatures and extraction of binary detection regions was proposed and evaluated. On the fixed simulation split, the network achieved ceiling-level held-out accuracy while retaining high performance across five NETD conditions; the 75-run overall accuracy and macro-F1 were 99.991883 ± 0.015786% and 99.902082 ± 0.036795%, respectively. In the fixed measured-data comparison against four traditional detectors and a recent deep learning method, the proposed 1D-CNN achieved the highest F1-score for all four gases and provided a more balanced Precision–Recall response. The evidence supports the effectiveness of the proposed method in the reported controlled simulations and fixed-platform scenes, but does not establish geometric multi-plume modeling, quantitative concentration retrieval, real-time edge deployment, generalization to unseen concentration combinations, broad cross-site performance, or airborne/mobile platform operation. The noise-specific results also showed increasing error at 0.50 K and should not be generalized to correlated sensor artifacts. Throughout this study, detection refers to gas presence classification and the delineation of predicted binary gas-present regions; no gas concentration field was retrieved.

Author Contributions

Conceptualization and methodology, S.W.; software, C.L.; validation, S.W.; formal analysis and investigation, S.W. and C.L.; resources, J.C.; data curation, C.L.; writing—original draft preparation, S.W.; writing—review and editing, J.S.; visualization, C.L.; supervision, J.S.; project administration and funding acquisition, J.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors on request.

Acknowledgments

During the preparation of this manuscript, the authors used Doubao 2.5.3_win for the purposes of English translation. The authors have reviewed and edited the output and take full responsibility for the content of this publication.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

The following abbreviations are used in this manuscript:
ATHISAirborne Thermal-Infrared Hyperspectral Imager System
RTReal-Time

References

  1. Hirsch, E.; Agassi, E. Detection of gaseous plumes in IR hyperspectral images—Performance analysis. IEEE Sens. J. 2010, 10, 732–736. [Google Scholar] [CrossRef] [Scilit]
  2. Scafutto, R.D.P.M.; de Souza Filho, C.R. Detection of heavy hydrocarbon plumes (ethane, propane and butane) using airborne longwave (7.6–13.5 μm) infrared hyperspectral data. Fuel 2019, 242, 863–870. [Google Scholar] [CrossRef] [Scilit]
  3. Harig, R.; Matz, G.; Rusch, P. Scanning infrared remote sensing system for identification, visualization, and quantification of airborne pollutants. In Instrumentation for Air Pollution and Global Atmospheric Monitoring; SPIE: Bellingham, WA, USA, 2002; Volume 4574, pp. 83–94. [Google Scholar]
  4. Sabbah, S.; Harig, R.; Rusch, P.; Eichmann, J.; Keens, A.; Gerhard, J.H. Remote sensing of gases by hyperspectral imaging: System performance and measurements. Opt. Eng. 2012, 51, 111717. [Google Scholar] [CrossRef] [Scilit]
  5. Tochon, G.; Chanussot, J.; Dalla Mura, M.; Bertozzi, A.L. Object tracking by hierarchical decomposition of hyperspectral video sequences: Application to chemical gas plume tracking. IEEE Trans. Geosci. Remote Sens. 2017, 55, 4567–4585. [Google Scholar] [CrossRef] [Scilit]
  6. Hirsch, E.; Agassi, E.; Manor, A. Using longwave infrared hyperspectral imaging for a quantitative atmospheric tracer monitoring in outdoor environments. Int. J. Geosci. 2021, 12, 233. [Google Scholar]
  7. Pogorzala, D.R.; Messinger, D.W.; Salvaggio, C.; Schott, J.R. Gas plume species identification by regression analyses. In Algorithms and Technologies for Multispectral, Hyperspectral, and Ultraspectral Imagery X; SPIE: Bellingham, WA, USA, 2004; Volume 5425, pp. 583–591. [Google Scholar]
  8. Li, S.; Peng, B.; Fang, L.; Li, Q. Hyperspectral band selection via optimal combination strategy. Remote Sens. 2022, 14, 2858. [Google Scholar] [CrossRef] [Scilit]
  9. Liao, Y.; Ye, F.; Li, M.; Xiong, H.; Cao, L. Matched Filtering Based on Background Radiance Estimation for Gas Detection with Thermal Infrared Hyperspectral Imaging. In Proceedings of the 2025 IEEE International Geoscience and Remote Sensing Symposium (IGARSS), Brisbane, Australia, 3–8 August 2025. [Google Scholar]
  10. Xu, T.; Xu, L.; Sun, Y.; Liu, W.; Liu, J. Robust identification of gas mixtures from FTIR spectra using attention mechanism to mitigate instrument line shape variations. Anal. Chem. 2025, 97, 23312–23320. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  11. Wang, Y.; Wan, L.; Song, Z.; Xu, L.; Liu, J.; Xu, H. Robust gas quantification in mid-infrared FTIR spectroscopy via a suppression-adaptation-optimization model. Opt. Express 2025, 33, 35865–35880. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  12. Liao, Y.; Xiong, H.; Cao, L.; Zhong, Y.; Shi, J. Long-wave Infrared Hyperspectral Gas Semantic Segmentation Network Based on Attention for Gas Detection. In Proceedings of the 2025 IEEE International Geoscience and Remote Sensing Symposium (IGARSS), Brisbane, Australia, 3–8 August 2025. [Google Scholar]
  13. Qin, Y.; Han, X.; Li, X.; Liu, H.; Gao, M.; Zhang, Y.; Liu, J.; Liu, W. Roadside Infrared Spectral Remote-Sensing Monitoring Method and System Based on VDL-DTCWT. CN118961639A, 21 October 2024. [Google Scholar]
  14. Lee, J.H.; Yu, H.G.; Park, D.J.; Park, B.H.; Kim, J.H. Characterization of hazardous gases using an infrared hyperspectral imaging system. Instrum. Sci. Technol. 2015, 43, 469–484. [Google Scholar] [CrossRef] [Scilit]
  15. Burr, T.; Hengartner, N. Overview of physical models and statistical approaches for weak gaseous plume detection using passive infrared hyperspectral imagery. Sensors 2006, 6, 1721–1750. [Google Scholar] [CrossRef] [Scilit]
  16. Foy, B.R.; Theiler, J.; Fraser, A.M. Decision boundaries in two dimensions for target detection in hyperspectral imagery. Opt. Express 2009, 17, 17391–17411. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  17. Gabrieli, A.; Wright, R.; Porter, J.N.; Lucey, P.G.; Honnibal, C. Applications of quantitative thermal infrared hyperspectral imaging (8–14 μm): Measuring volcanic SO2 mass flux and determining plume transport velocity using a single sensor. Bull. Volcanol. 2019, 81, 47. [Google Scholar] [CrossRef] [Scilit]
  18. Schaum, A. A uniformly most powerful detector of gas plumes against a cluttered background. Remote Sens. Environ. 2021, 260, 112443. [Google Scholar] [CrossRef] [Scilit]
  19. Zeng, Z.C.; Natraj, V.; Xu, F.; Chen, S.; Gong, F.-Y.; Pongetti, T.J.; Sung, K.; Toon, G.; Sander, S.P.; Yung, Y.L. GFIT3: A Full Physics Retrieval Algorithm for Remote Sensing of Greenhouse Gases in the Presence of Aerosols. Atmos. Meas. Tech. 2021, 14, 6483–6507. [Google Scholar] [CrossRef] [Scilit]
  20. Chen, W.; Ren, T.; Zhao, C.; Wen, Y.; Gu, Y.; Zhou, M.; Wang, P. Transformer-based fast mole fraction of CO2 retrievals from satellite-measured spectra. J. Remote Sens. 2025, 5, 0470. [Google Scholar] [CrossRef] [Scilit]
  21. Xiong, H.; Cao, L.; Wang, D.; Du, Y.; Zhong, Y.; Wang, S. CFDNet: Coupling Computational Fluid Dynamics with Convolutional Neural Networks for Gas Detection Using Thermal Infrared Multispectral Video. IEEE Trans. Geosci. Remote Sens. 2025, 63, 1–17. [Google Scholar] [CrossRef] [Scilit]
  22. Hong, D.; Han, Z.; Yao, J.; Gao, L.; Zhang, B.; Plaza, A.; Chanussot, J. SpectralFormer: Rethinking Hyperspectral Image Classification with Transformers. IEEE Trans. Geosci. Remote Sens. 2022, 60, 5518615. [Google Scholar] [CrossRef] [Scilit]
  23. Tian, X.G.; Zuo, Q.W.; Zhang, J.M.; Zhang, C.M.; Sun, M.S. Research on the construction of a harmful chemical gas diffusion prediction network combining data and physical constraints. CBRN Def. 2023, 2, 59–65. [Google Scholar]
  24. Liu, C.; Xu, R.; Xie, F.; Jin, J.; Yuan, L.; Lv, G.; Wang, Y.; Li, C.; Wang, J. New airborne thermal-infrared hyperspectral imager system: Initial validation. IEEE J. Sel. Top. Appl. Earth Obs. Remote Sens. 2020, 13, 4149–4165. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.