Characterization of the Implementation of Solar Photovoltaic Systems for Sustainable Urban Energy Planning in the Urban Area of Cuenca, Ecuador

,
,
,
and
1
Department of Electrical Engineering, Electronics and Telecommunications, Campus Balzay, University of Cuenca, Cuenca 010150, Ecuador
2
CONSISO Laboratory, School of Architecture, CIITT, Universidad Católica de Cuenca, Patamarca St. & Cojimíes, Cuenca 010102, Ecuador
*
Authors to whom correspondence should be addressed.
This article belongs to the Section Energy Sustainability

Abstract

This study characterizes the photovoltaic potential of three urban areas in Cuenca, Ecuador, located in the San Sebastián, Totoracocha, and Yanuncay parishes, through twelve technical, energy-related, socioeconomic, and environmental indicators. The analysis was complemented with grid simulations in CYME 9.2 to assess photovoltaic integration capacity in the distribution network and with a multicriteria synthesis using PROMETHEE II. The variables considered included solar irradiation, usable rooftop area, electricity consumption, population density, socioeconomic level, and the operating characteristics of distribution transformers. The results show that photovoltaic potential varies according to urban morphology, electricity demand, and the operating capacity of the grid. Totoracocha exhibited the highest theoretical potential and a self-sufficiency level of 99.1%, but it also recorded the lowest technical utilization factor, at 15.6%, because of transformer constraints. Yanuncay achieved the highest estimated technically available surplus under the evaluated operating scenarios, at 452,737 kWh/year, whereas San Sebastián exhibited the highest technical utilization factor, at 27.2%. The simulations confirmed that transformers constitute the main technical constraint on photovoltaic integration, while medium-voltage lines and voltage levels remained within their operating limits. The technically usable surplus energy could be allocated to induction cooking, electric mobility, or green hydrogen production as alternative, non-simultaneous scenarios. The energy allocated to self-sufficiency could avoid approximately 1022.5 tCO2/year. Orientation analysis showed statistically significant but limited differences among the evaluated configurations, indicating that orientation should be considered together with other rooftop and grid-related factors rather than as a standalone feasibility criterion. Overall, the proposed integrated framework provides a comparative decision-support basis for sustainable urban photovoltaic planning by jointly considering rooftop potential, electricity demand, grid constraints, socioeconomic conditions, and environmental benefits.

1. Introduction

The transition toward more sustainable energy systems is one of the main challenges facing contemporary power system planning. In this context, solar photovoltaic (PV) generation has become a relevant alternative for diversifying the energy mix, reducing CO2 emissions, and strengthening distributed generation in urban environments [1]. Its technological maturity, together with the progressive decline in costs and the possibility of installing modules on built surfaces, has increased interest in its integration into rooftops, and buildings [2]. This condition is particularly important in intermediate cities, where electricity demand is concentrated in urban areas and the use of rooftops can reduce the need to occupy additional land for renewable generation.
Ecuador’s geographical location near the Equator favors relatively stable solar availability throughout the year. According to national reports, average daily irradiation ranges from 1.41 to 6.35 kWh/m2, with favorable conditions in the coastal and Andean regions [3,4]. This availability makes distributed PV generation a strategic option for complementing the national power system, particularly under scenarios of demand growth, hydropower dependence, and vulnerability during low-water periods. However, the use of this resource in urban areas depends not only on incident radiation but also on available usable areas, building morphology, consumption patterns, and the operating capacity of the distribution network.
Urban PV potential has commonly been assessed using geographic information systems, LiDAR data, cadastral information, digital surface models, and solar simulations. These methods identify usable rooftop areas by considering geometric, technical, and shading constraints and have been applied in both European and Ecuadorian cities [5,6,7,8,9,10,11,12]. Studies conducted in Ecuador confirm the existence of substantial theoretical rooftop potential; however, the amount of energy that can ultimately be used depends on building morphology, electricity demand, and the characteristics of the distribution network [8,9,10,11,12].
Other studies have examined specific components of urban PV implementation. Research on orientation and tilt indicates that, in equatorial locations, low-slope configurations produce relatively small differences in annual energy generation [13,14,15]. Multidimensional approaches have incorporated technical, environmental, social, and consumption-related indicators [16,17,18], whereas distribution network studies have evaluated reverse power flow, voltage rise, losses, and transformer or conductor overloading [19,20,21,22]. Separately, surplus-energy studies have analyzed PV surplus energy and its potential use in new electrical loads, including induction cooking, electric mobility, and hydrogen production [23,24,25,26,27,28].
Despite these advances, these components are generally evaluated independently. Rooftop-assessment methods commonly quantify gross solar-generation potential without determining the share that can be integrated under actual distribution network constraints. In contrast, network studies frequently examine predefined PV penetration levels without relating them to the spatial rooftop potential or to the energy and socioeconomic characteristics of the surrounding urban area. Similarly, surplus-energy applications are often evaluated without being linked to the grid-admissible PV potential of the same transformers and users.
This study addresses this gap through an integrated, multiscale framework. Unlike approaches limited to gross rooftop potential or isolated network simulations, the proposed method links building-level generation and demand with area-level technical, energy-related, socioeconomic, and environmental indicators and transformer-level load-flow simulations. This integration makes it possible to distinguish theoretical PV potential from grid-admissible potential under the evaluated operating scenarios, identify the elements that constrain integration, estimate annual energy-equivalent uses of the technically available surplus, and synthesize the differentiated performance of the study areas using PROMETHEE I and II. The framework is intended as a comparative planning-support tool rather than as a substitute for detailed time-series hosting-capacity or economic-feasibility studies.
Against this background, the proposed framework is applied to three urban areas of Cuenca, Ecuador, located in the San Sebastián, Totoracocha, and Yanuncay parishes. Georeferenced rooftop and electricity consumption information is combined with population, socioeconomic, and distribution network data to construct twelve comparative indicators. Load-flow simulations in CYME 9.2 are then used to estimate the PV potential admissible under the selected operating conditions, while PROMETHEE I and II are applied to obtain the partial and complete rankings of the study areas.
The main contributions of this work are as follows:
  • A multiscale framework is developed to link building-level generation and demand, area-level multidimensional indicators, and transformer-level grid constraints.
  • Theoretical PV potential is compared with the estimated technical PV potential admissible under the evaluated operating scenarios using load-flow simulations in CYME (v9.2).
  • The technically available PV surplus is translated into annual energy-equivalent scenarios for induction cooking, residential electric mobility, and green hydrogen production.
  • PROMETHEE (v1.4.0.0) I and II integrate the technical, energy-related, socioeconomic, and environmental indicators to identify the differentiated strengths and constraints of each urban area.
The remainder of this paper is organized as follows. Section 2 describes the study area, input data, indicators, and distribution network simulation scenarios. Section 3 presents the results related to radiation by orientation, area-level indicators, theoretical potential, technical potential, surplus energy, and avoided emissions. Section 4 discusses the findings in relation to literature and analyzes their technical implications for urban PV planning. Finally, Section 5 summarizes the main conclusions, limitations, and directions for future research.

2. Materials and Methods

2.1. General Methodological Approach

The study followed a quantitative, descriptive, and comparative approach. The analysis integrated information on solar irradiation, usable rooftop areas, electricity consumption, population density, socioeconomic level, and the operating characteristics of distribution transformers. This information was used to characterize the urban PV potential of three representative areas in Cuenca, Ecuador, and to assess their actual capacity for integration into the electrical grid.
The methodological procedure was structured into six stages (Figure 1). First, input data associated with the solar resource, available rooftops, electricity demand, and the distribution network were collected and processed. Second, technical, energy-related, socioeconomic, and environmental indicators were calculated. Third, theoretical PV potential and the level of energy self-sufficiency were estimated. Fourth, PV integration into the grid was assessed through simulations in CYME 9.2. Fifth, technically usable surplus energy and the associated avoided emissions were estimated. Finally, the relative importance of the twelve indicators was determined through expert assessment, and the resulting weights were incorporated into a multicriteria analysis using PROMETHEE I and II.
Figure 1. Methodological framework for characterizing urban PV potential under grid constraints.

2.2. Study Area and Input Data

The study areas were selected from sectors previously identified within the “Energy Implications of Urban Transformation in Intermediate Cities: Case Study of Cuenca, Ecuador” [29], macro-project to represent contrasting building-height and urban-morphology configurations found in Cuenca (Figure 2). The selection considered differences in residential concentration, rooftop availability, solar exposure, and the degree of obstruction produced by the surrounding built environment. These characteristics allow low- and medium-rise sectors, where obstruction between buildings is generally lower, to be compared with heterogeneous areas in which two- or three-story houses coexist with taller buildings and greater rooftop shading may occur.
Figure 2. Location of the study areas in urban Cuenca, Ecuador: San Sebastián ①, Totoracocha ②, and Yanuncay ③. The inset map highlights the city of Cuenca within the province of Azuay in orange, with the urban parish of Cuenca containing the study areas identified in green.
The San Sebastián area corresponds to the Av. Ordóñez Lasso sector and covers approximately 168,781 m2. It represents a heterogeneous and relatively high-rise urban configuration comprising residential condominiums, hotels, taller buildings, and detached houses. The Totoracocha area covers approximately 77,384 m2 and represents a predominantly residential low- and medium-rise sector. The Yanuncay area corresponds to the Av. Primero de Mayo sector, with an area of approximately 134,979 m2, and consists is characterized mainly by detached houses, although some residential condominiums are also present. As illustrated in Figure 2, the location context highlights the city of Cuenca within the province of Azuay in orange, while the inner green area identifies the urban parish of Cuenca containing the three evaluated study sectors. Together, these areas allow PV potential to be assessed under contrasting conditions of building height, urban concentration, rooftop availability, and solar exposure.
Once urban typologies had been selected, the analysis incorporated the actual distribution networks associated with each sector, as provided by EERCS, allowing differences in electricity demand, transformer capacity, and transformer loading to be considered when estimating the PV potential admissible under the evaluated scenarios.
Solar radiation and usable-rooftop-area data were obtained from a georeferenced database developed within the institutional project “Energy Implications of Urban Transformation in Cities” [29]. The database includes building-level information on rooftop orientation, incident solar irradiation, and estimated annual PV generation potential. Electricity consumption data and transformer technical data were provided by Empresa Eléctrica Regional Centro Sur C.A. (EERCS). Population-density and socioeconomic-level data reported for the urban parishes of Cuenca were also incorporated [30]. The main characteristics of the urban typologies represented by the selected study areas are summarized in Table 1.
Table 1. Main characteristics of the urban typologies represented by the selected study areas.
Population densities adjusted to the conditions of each area were used to calculate per-capita indicators. In San Sebastián, a density of 105 inhabitants/ha was adopted, exceeding the reported parish-level value of 55 inhabitants/ha because of the concentration of condominiums, residential complexes, hotels, and taller buildings in the Av. Ordóñez Lasso sector. This decision was contrasted with the number of electricity meters per hectare, which was higher in San Sebastián than in Totoracocha and Yanuncay. Although this parameter is not directly equivalent to population density, it provides an approximation of the relative concentration of electricity users within the evaluated area and supports the use of an adjusted density for the analyzed sector (Table 2).
Table 2. Adopted population density and electricity-meter concentration in the study areas. Source: Authors’ calculations based on data provided by EERCS and population-density data from [29,30].

2.3. Solar Irradiation and Rooftop Orientation Assessment

The influence of rooftop orientation on the available solar resource was evaluated using the mean monthly solar irradiation of each roof surface, obtained from the values corresponding to the twelve months of the year. Roof surfaces were grouped according to north, south, east, and west orientations. Before the statistical analysis, outliers within each group were identified using Tukey’s interquartile-range criterion, considering values below Q 1 − 1.5 × I Q R   or above Q 3 + 1.5 × I Q R as outliers, and were excluded from the analysis. The mean, standard deviation, and 95% confidence interval were calculated for each group. Each roof surface was treated as the observational unit. Normality and homogeneity of variances were assessed using the Shapiro–Wilk and Levene tests, respectively. Because these assumptions were not fully satisfied, differences among orientations were evaluated using Welch’s ANOVA, followed by Games–Howell post hoc comparisons, with a significance level of α = 0.05. In addition, η2 was calculated to quantify the magnitude of the orientation effect.

2.4. Assessment of Solar Irradiation and Indicators

A set of technical, socioeconomic, and environmental indicators was constructed from the input data. These indicators enabled comparison of the study areas in terms of PV generation, electricity consumption, self-sufficiency, energy surplus, per-capita availability, technical grid utilization, and potential emissions reduction. Table 3 summarizes the indicators used in the study.
Table 3. Indicators used in the study and their classification by dimension. Source: Authors’ own elaboration.

2.5. Transformer Selection and Grid Simulation

The technical assessment was conducted at the distribution transformer level. Because of the number of units present in the analyzed areas, a subset of transformers was purposively selected to reduce model complexity and focus the analysis on relevant PV integration points. The selection criteria were as follows: only three-phase transformers were considered because of the compatibility requirements of the PV model implemented in CYME 9.2; units with at least 50% of their customers located within the study area were included; higher-rated transformers were prioritized when more than ten units of the same ownership type were present within an area; and only transformers in operation were considered. Because the selection was based on these technical and modeling criteria rather than on probabilistic or stratified sampling, it was not intended to provide equal sample sizes or equivalent coverage across the three study areas. Therefore, the analyzed transformers should be interpreted as technically selected subsets rather than as statistically representative samples of the complete transformer population in each area. The restriction to three-phase units reflects a modeling limitation and does not imply the technical exclusion of single-phase transformers from PV integration.
The main characteristics of the selected transformers are presented in Appendix A. For confidentiality reasons, the actual identification codes were omitted, and only the reference numbering used in the analysis is retained. The coverage resulting from this selection procedure is reported in Table A2. The proportion of simulated transformers ranged from 22.22% to 42.86% of the units present in each study area, whereas the annual demand associated with these transformers represented between 31.37% and 50.51% of the total demand. These differences reflect the fact that transformer selection was based on technical and modeling criteria rather than on obtaining equal sample sizes or equivalent coverage across the study areas.
The PV power required to cover the annual demand associated with each transformer was calculated using the capacity factor. This factor relates annually generated energy to the maximum energy that a system would produce if it operated at rated power throughout the year [36]. The required rated power was estimated using Equation (1):
P P V , t = E d e m , t / ( 8760   h × F C ) ,
where P P V , t   is the PV power required for transformer t, E d e m , t is the annual demand associated with the transformer, and FC is the capacity factor, and 8760 h represents the total number of hours in year. A capacity factor of FC = 0.14 was adopted in this study. Attari et al. [36] reported an annual capacity factor of 14.84% for a grid-connected PV system. In the Ecuadorian context, Mogrovejo-Narvaez et al. [37] reported capacity factors ranging approximately from 14% to 19%, whereas Zalamea-León et al. [38] experimentally obtained a capacity factor of 14.35% for a building-integrated PV system at the University of Cuenca. Therefore, a value of 0.14 was considered a conservative and representative approximation of local operating conditions.
The feeders used in CYME 9.2 correspond to digital representations of actual operating networks provided by Empresa Eléctrica Regional CENTROSUR C.A. (EERCS), retaining their topology, equipment, and loads. The load associated with each transformer represents the aggregated demand of its registered customers; therefore, no uniform synthetic load model or single power factor was imposed on all users.
PV generation was represented using the generic CYME element, configured as a three-phase inverter connected in delta to phases AB, BC, and CA, operating at unity power factor without reactive-power exchange. Active power was adjusted individually according to the PV system considered for each transformer and scenario.
Before PV generation was incorporated, a base-case load flow was performed to establish the initial voltage, loading, power-flow, and loss conditions. For the 22 kV buses, a range from 0.94 to 1.06 p.u. was adopted, corresponding to the ±6% limit established for medium voltage by Regulation No. ARCONEL 009/24, while transformer loading was limited to 100% of rated capacity [4]. Because the analysis uses aggregated loads, unity-power-factor inverters, and two selected operating conditions, the results are interpreted as estimates of the technically admissible PV potential under the evaluated scenarios.
To represent the hourly demand behavior, the demand curves of the feeders associated with the Totoracocha, San Sebastián, and Yanuncay sectors were used, as shown in Figure 3. The operating conditions were selected jointly based on these curves and the hourly solar irradiance trend shown in Figure 4. As observed in both figures, high solar irradiance occurs around 13:00 and coincides with low electricity consumption in the feeders; this condition was selected to assess the effects of high PV integration on the network. In contrast, 20:00 corresponds to the period of maximum active demand, when PV generation is zero, and was used to evaluate the incorporation of new loads. These times represent selected operating conditions and do not replace a complete hourly or seasonal time-series simulation.
Figure 3. Hourly active-power demand curves of the feeders associated with the Yanuncay, San Sebastián, and Totoracocha sectors. Source: Authors’ own elaboration based on data provided by EERCS.
Figure 4. Daily solar irradiance trend and selection of the simulation time. The black dot and the vertical dashed line indicate the specific hour (13:00 h, as shown in the legend) selected for the PV power flow simulations, representing near-peak irradiance conditions. Source: Adapted from [39].
Load-flow simulations were performed in CYME 9.2 [40] and structured into two scenarios. The first scenario was evaluated at 13:00, an interval characterized by high solar availability and low feeder demand. For transformers with a theoretical surplus, the PV systems were initially sized to cover annual demand; when the physical rooftop potential was insufficient, the maximum available potential was incorporated. The second scenario was evaluated at 20:00, corresponding to feeder peak demand and zero PV generation. In this case, the calculated surplus energy was represented as equivalent new loads to verify whether it could be supplied by the remaining transformer capacity.
Transformer and medium-voltage-line loading, power flow, losses, and voltage levels were evaluated in both scenarios. A maximum load of 100% was adopted as the operating limit. Whenever a proposed integration exceeded this value, the PV power or usable surplus energy was reduced until a condition at or below the established limit was achieved.

2.6. Estimation of Surplus Energy and Avoided Emissions

The technical PV potential of each area was obtained from the maximum generation admissible in the selected transformers without exceeding the established loading limit. The technically usable surplus was calculated as the difference between technically admissible energy and the annual demand associated with the transformers. These surpluses were subsequently evaluated as independent alternatives for supplying induction cooking, electric vehicles, or green hydrogen production.
For induction cooking, an incremental consumption of 109.26 kWh/month per user was adopted, equivalent to 1311.12 kWh/year per cooker [41]. For electric mobility, a daily travel distance of 30 km/day and an average consumption of 16.92 kWh/100 km were considered. The latter value was obtained from references addressing electric mobility in Ecuador and high-altitude cities [42,43,44], resulting in an equivalent annual demand of 1852.7 kWh per vehicle.
Green hydrogen production was analyzed as a chemical energy storage alternative based on electrolysis. A proton exchange membrane (PEM) electrolyzer efficiency of 75%, an availability factor of 0.95, and a higher heating value of hydrogen of 39.40 kWh/kg H2 were considered [27,44]. The cooking, mobility, and hydrogen scenarios were interpreted as alternative rather than simultaneous uses.
Emissions reductions from displaced grid electricity were estimated solely by the PV energy allocated to covering the self-sufficiency demand of the analyzed users, excluding surplus energy. The combined ex post margin applicable to wind and solar projects in Ecuador’s National Interconnected System, equal to 0.4922 tCO2/MWh, was used [35]. Avoided emissions from replacing liquefied petroleum gas (LPG) through induction cooking and gasoline through electric vehicles were also estimated. These estimates correspond to equivalent annual energy balances rather than hourly simulations of the coincidence between generation and demand.

2.7. Survey-Based Indicator Weighting and PROMETHEE Analysis

The relative importance of the twelve technical, energy-related, socioeconomic, and environmental indicators was determined through a structured survey. The survey targeted participants associated with the academic, public, private, and energy sectors, according to the professional sector reported by each respondent in the questionnaire. Twenty participants with knowledge related to the energy and photovoltaic fields were initially selected and contacted by email to participate voluntarily in the study. Thirteen valid responses were received and included in the analysis. Before completing the survey, the questionnaire included an explicit request for consent to use the information provided for research purposes. The responses were treated confidentially and are reported anonymously in Appendix A. Each indicator was evaluated using a five-point ordinal scale. A score of 1 represented very low importance, 2 low importance, 3 moderate importance, 4 high importance, and 5 very high importance.
For each criterion j, the mean importance score was calculated using Equation (2):
x j ¯ = 1 n ∑ i = 1 n x i j ,
where x i j is the importance score assigned by participant i to criterion j, and n is the total number of valid responses.
The mean scores were subsequently normalized to obtain the weight assigned to each criterion:
w j = x j ¯ / ∑ k = 1 12 x ¯ k ,
where w j   is the normalized weight of criterion j. The resulting weights satisfy the following condition:
∑ j = 1 12 w j = 1 ,
The variability of the responses was characterized using the sample variance of each criterion. In addition, the internal consistency of the response matrix was assessed using Cronbach’s alpha.
The three study areas: San Sebastián, Totoracocha, and Yanuncay, were defined as the alternatives, while the twelve indicators were used as evaluation criteria. The complete decision matrix, including criterion values, units, and preference directions, is provided in Table A4 of Appendix A. Indicators associated with solar resource availability, PV generation, energy availability, energy surplus, self-sufficiency, socioeconomic conditions, technical PV utilization, and emissions reduction were configured for maximization. Electricity consumption indicators were configured for minimization because lower values represent lower energy requirements relative to the available PV resource. The socioeconomic indicator was configured for maximization because higher values represent relatively more favorable socioeconomic conditions for PV adoption within the proposed comparative framework.
The usual preference function was assigned to all criteria. This function establishes a strict preference for the alternative with the better performance value and does not require the definition of indifference or preference thresholds. The normalized weights obtained from the survey responses were incorporated into the multicriteria model.
PROMETHEE I applied to obtain the partial ranking of the alternatives by jointly examining the positive and negative preference flows. The positive flow, Φ+(a), represents the extent to which alternative a outranks the other alternatives, whereas the negative flow, Φ−(a), represents the extent to which it is outranked by them. This analysis also allows the identification of preference, indifference, or incomparability relationships.
PROMETHEE II was subsequently applied to obtain a complete ranking through the net preference flow:
Φ ( a ) = Φ + ( a ) − Φ − ( a ) ,
where a higher value of Φ(a) indicates a more favorable overall performance of alternative a. The multicriteria analysis was implemented using Visual PROMETHEE.
Although some indicators are derived from common underlying variables, particularly electricity consumption, PV generation, and population, they were retained because they describe complementary aspects of the problem at different scales, including per-capita, building, area, and transformer levels. Therefore, these criteria were not assumed to represent statistically independent dimensions.
Finally, a sensitivity analysis was performed to evaluate the dependence of the ranking on the weighting scheme. PROMETHEE was rerun by assigning equal weights to all twelve criteria, ω j = 1 / 12 , while keeping the decision matrix, preference directions, and preference functions unchanged (Table 4). The resulting PROMETHEE II flows were then compared with those obtained using the survey-derived weights.
Table 4. Preference direction of the criteria used in the PROMETHEE analysis.

3. Results

3.1. Solar Irradiation by Rooftop Orientation

Table 5 presents the mean solar radiation values and their standard deviations for each rooftop orientation in the three study areas. The highest average values were recorded for west-facing rooftops in Totoracocha and Yanuncay, at 131.9 kWh/m2 and 128.7 kWh/m2, respectively. In San Sebastián, the highest value was obtained for south-facing rooftops, at 124.7 kWh/m2.
Table 5. Descriptive statistics of mean monthly solar irradiation by rooftop orientation after outlier removal.
The Shapiro–Wilk tests indicated deviations from normality in all twelve orientation groups (p < 0.01). In addition, Levene’s test indicated unequal variances in Totoracocha (p = 0.025), Yanuncay (p < 0.001), and San Sebastián (p < 0.001). Considering the large sample sizes and, particularly, the unequal variances, differences among orientations were assessed using Welch’s ANOVA followed by Games–Howell pairwise comparisons. The results are presented in Table 6.
Table 6. Results of the one-way ANOVA applied to solar irradiation by rooftop orientation.
The analysis confirmed statistically significant differences among orientations in all three study areas. However, the magnitude of the effect was limited: orientation explained between 2.7% and 4.5% of the observed variability in irradiation, while the difference between the highest and lowest mean orientations was 2.83% in Yanuncay, 3.20% in Totoracocha, and 4.73% in San Sebastián. Games–Howell comparisons showed that not all orientations differed significantly from one another. In Totoracocha, west-facing surfaces were higher than north-, south-, and east-facing surfaces; in Yanuncay, significant differences were identified for north–south, west–south, and west–east; and in San Sebastián for south–north, south–west, and east–west (Figure 5).
Figure 5. Comparison of mean solar irradiation according to the best rooftop orientation in the study areas. Source: Authors’ own elaboration.

3.2. Area-Level Energy and Socioeconomic Indicators

Table 7 summarizes the main energy, socioeconomic, and photovoltaic indicators calculated at the area level. The results show that San Sebastián exhibits the highest annual electricity consumption per capita, at 2355.49 kWh/person·year. Yanuncay records 1828.42 kWh/person·year, whereas Totoracocha has the lowest per-capita consumption, at 1785.78 kWh/person·year. These differences reflect the electricity-demand characteristics and urban configuration of each area.
Table 7. Area-level energy, socioeconomic, and photovoltaic indicators.
In contrast, Totoracocha presents the highest potential PV energy availability per capita, at 15,517.90 kWh/person·year, followed by Yanuncay at 14,696.64 kWh/person·year and San Sebastián at 6668.72 kWh/person·year. Therefore, Totoracocha lower per-capita consumption, together with its high potential PV energy availability, contributes to its favorable performance in theoretical energy indicators.
The three study areas present theoretically favorable conditions for building-level energy self-sufficiency. The I E A indicator represents the percentage of buildings whose potential rooftop PV generation is sufficient to meet their annual electricity demand. Totoracocha achieves the highest value, with 99.1% of the buildings reaching self-sufficiency, followed by Yanuncay at 98.4% and San Sebastián at 93.9%.
These percentages do not represent the aggregate relationship between total generation and total demand in each area. That relationship is expressed through the area-level energy-surplus indicator, I S E P Z Totoracocha presents the highest theoretical surplus, at 8.69, followed by Yanuncay at 8.04 and San Sebastián at 2.83. The lower value obtained for San Sebastián is associated with its higher annual electricity demand and the concentration of buildings with greater electricity consumption.
PV energy density also differs among the study areas. Totoracocha records the highest value, at 135 kWh/m2·year, followed by Yanuncay at 95 kWh/m2·year and San Sebastián at 70 kWh/m2·year. This indicator relates theoretical PV generation to the total urban area analyzed and reflects the influence of urban morphology and relative rooftop availability.

3.3. Technical Assessment of Photovoltaic Grid Integration

The assessment in CYME 9.2 enabled comparison of theoretical PV potential with an estimate of the technically admissible potential under the selected operating scenarios. The results show that PV integration mainly affects transformer loading, whereas changes in medium-voltage-line loading and voltage levels were small.
In the preliminary self-sufficiency scenario, transformers 23, 21, 20, and 17 exceeded 100% loading. Consequently, the proposed PV powers were reduced from 85 to 65 kW, from 160 to 102 kW, from 114 to 87 kW, and from 101 to 68 kW, respectively. After these adjustments, final loading levels were limited to 99.94%, 96.77%, 98.87%, and 99.83%.
Under the peak-demand scenario, transformer 22 had an initial loading of 108.0%, and therefore no margin was considered for additional loads. Similarly, the surplus associated with transformer 18 was reduced from 53 to 38 kW, decreasing its loading from 114.4% to 98.6%. These adjustments ensure that the reported technical potential corresponds to an operating condition that does not exceed the adopted limit.
Figure 6 presents the variation in transformer power flow under the evaluated scenarios. Conditions without PV generation, with systems sized for self-sufficiency, and with maximum PV generation are compared. The results identify reverse power flow in some transformers, demonstrating that the capacity of these units is a relevant constraint on PV integration.
Figure 6. Comparison of transformer power flow under three simulation scenarios: without PV generation, self-sufficiency, and maximum PV generation.
Figure 7 presents medium-voltage-line loading under the simulation scenarios. The values remain within acceptable operating ranges, indicating that the lines are not the main constraint on PV integration in the analyzed sectors.
Figure 7. Medium-voltage-line loading under different PV integration scenarios.
Complementarily, Figure 8 shows voltage levels at the buses associated with the evaluated transformers. Although PV integration tends to slightly increase voltage levels, the values remain close to 1 p.u., and no overvoltage conditions are observed.
Figure 8. Voltage levels at buses associated with the analyzed transformers, considering a base voltage of 22 kV.
The losses showed that losses remained below 2% for most of the transformers evaluated. The largest increases were associated with isolated overload conditions in the preliminary self-sufficiency scenario; after PV power was limited, losses did not constitute the binding constraint in the study.
These results indicate that technically usable PV potential is mainly conditioned by distribution transformer capacity. Therefore, the theoretical potential available on rooftops cannot be interpreted directly as energy that can be integrated into the grid without evaluating operating constraints.

3.4. Comparison of Theoretical and Technical Photovoltaic Potential for the Selected Transformers

Table 7 considers all buildings located within each study area, whereas Table 8 includes only the subset associated with the selected transformers. This distinction ensures that the theoretical and technical potential values reported in Table 8 are calculated using the same spatial and electrical scope.
Table 8. Comparison of theoretical PV potential, estimated technical PV potential, surplus and utilization factors for the selected transformers.
Within this subset, theoretical PV potential represents the estimated annual generation from the rooftops associated with the selected transformers before distribution network operating constraints are considered. In contrast, technical PV potential represents the annual-equivalent generation admissible under the evaluated operating scenarios after PV power is limited to prevent transformers from exceeding the adopted loading threshold. Therefore, the difference between these values represents the effect of grid constraints on the analyzed scenarios (Figure 9).
Figure 9. Comparison of theoretical PV potential, technical PV potential, surplus, and utilization factor by study area.
San Sebastián has the highest total technical potential, at 1,450,831 kWh/year. However, this value must be interpreted considering that a larger number of transformers were analyzed in this area. Therefore, it does not necessarily imply better individual technical conditions than in the other areas.
Totoracocha records the highest theoretical potential, at 5,416,798 kWh/year, and the highest theoretical surplus, at 9.09. Nevertheless, its technical potential decreases to 846,216 kWh/year, with a utilization factor of 15.6%. This result demonstrates that high theoretical generation availability does not guarantee proportional technical utilization.
Yanuncay exhibits the highest technical surplus, at 2.88, despite having a lower theoretical potential than the other areas. This indicates that the available capacity of its transformers enables a larger share of surplus energy to be used under the evaluated constraints.
To synthesize these results, Figure 10 provides a visual comparison of the main indicators calculated for the three study areas. This representation jointly displays variables associated with the solar resource, electricity consumption, energy availability per capita, self-sufficiency, energy surplus, and PV potential. Overall, the figure shows that Totoracocha performs better in theoretical generation indicators, whereas Yanuncay maintains favorable results in self-sufficiency and surplus. San Sebastián, in turn, exhibits greater relative constraints because of its higher per-capita electricity consumption, lower per-capita energy availability, and lower PV energy density.
Figure 10. Comparative synthesis of the main urban PV potential indicators by study area.

3.5. Use of Photovoltaic Surplus Energy

After grid constraints were considered, the total technically usable PV surplus was 940,767 kWh/year. Yanuncay had the highest surplus, at 452,737 kWh/year, followed by Totoracocha at 250,334 kWh/year and San Sebastián at 237,696 kWh/year.
Table 9 summarizes the potential use of this surplus energy in three applications: induction cooking, electric vehicles, and green hydrogen production.
Table 9. Potential use of PV surplus energy in new electrical loads.
The results show that Yanuncay has the highest surplus-energy utilization capacity. For electric cooking, it could supply approximately 345 induction cookers, equivalent to a potential coverage of 88.5% of the customers analyzed. For electric mobility, the surplus energy could supply 244 residential electric vehicles. Estimated green hydrogen production would reach 8187.19 kg/year.
Overall, the technically usable PV surplus energy could supply 717 induction cookers, 507 electric vehicles, or produce 17,012.60 kg of green hydrogen per year. The results represent annual energy equivalents and do not consider the hourly coincidence between PV surplus-energy availability and the operation of the new loads; therefore, they should not be interpreted as directly implementable capacities.

3.6. Potential Reduction in CO2 Emissions

Emissions reductions from the displacement of grid electricity were estimated from the annual demand covered by PV generation, excluding surplus energy. The total energy allocated to self-sufficiency was 2,077,521 kWh/year: 551,880 kWh/year in Totoracocha, 1,188,381 kWh/year in San Sebastián, and 337,260 kWh/year in Yanuncay. Applying an emission factor of 0.4922 tCO2/MWh yielded a total estimated reduction of 1022.55 tCO2/year, distributed as 271.64 tCO2/year for Totoracocha, 584.92 tCO2/year for San Sebastián, and 166.00 tCO2/year for Yanuncay.
Avoided emissions from the alternative use of surplus energy in induction cooking and electric mobility were also evaluated. Table 10 presents the results for each area.
Table 10. Avoided emissions from the use of PV surplus energy.
Using surplus energy for induction cooking could displace approximately 211,884.45 kg of LPG per year and avoid 642.01 tCO2/year from direct combustion. For electric mobility, the surplus could support approximately 5,560,088.66 km/year of travel, displace 400,326.38 L of gasoline, and avoid 920.75 tCO2/year. These results demonstrate the potential of surplus PV energy to support urban electrification processes, provided that flexible loads and management strategies are available to absorb the energy.

3.7. Survey-Derived Weights and Multicriteria Synthesis Using PROMETHEE

The twelve indicators were assessed using a five-point importance scale. The mean importance scores obtained from the survey responses were normalized so that the sum of the criterion weights was equal to one. Table 11 presents the mean importance scores, sample variances, and normalized weights obtained from the 13 valid survey responses. The anonymized individual ratings used to derive these values are provided in Table A3 of Appendix A.
Table 11. Mean importance scores and normalized indicator weights derived from the survey responses.
Mean importance scores ranged from 3.9231 to 4.3077, while the normalized weights ranged from 7.8341% to 8.6022%. The difference between the highest and lowest weights was only 0.7681 percentage points, indicating a relatively balanced weighting structure in which no single criterion dominated the multicriteria assessment. The response matrix also showed adequate internal consistency, with a Cronbach’s alpha of α = 0.8632 .
The normalized weights were subsequently incorporated into the PROMETHEE model together with the complete decision matrix presented in Table A4 of Appendix A. PROMETHEE I was first applied to examine the partial ranking by jointly considering the positive and negative preference flows and to identify possible incomparability relationships among the study areas. Figure 11 presents the resulting partial ranking under the survey-derived weighting scenario.
Figure 11. PROMETHEE I partial ranking of the evaluated zones. Green bars indicate positive net, representing higher preference, while red bars denote negative net flows, representing lower preference. Source: Authors’ own elaboration.
The evaluation of the study areas using the PROMETHEE II complete ranking method yielded consistent results across both weighting structures (Table 12).
Table 12. PROMETHEE II results under survey-derived and equal-weight scenarios.
Under the survey-derived weighting scenario, Totoracocha ranked first with a net preference flow of 0.4221, followed by Yanuncay with 0.0147 and San Sebastián with −0.4368. The net-flow difference between Totoracocha and Yanuncay was 0.4074, indicating a clear separation between the first- and second-ranked areas.
The equal-weight scenario produced the same ranking, with net flows of 0.4189 for Totoracocha, 0.0133 for Yanuncay, and −0.4322 for San Sebastián. The separation between the first two alternatives was 0.4056, compared with 0.4074 under the survey-derived weighting scenario, while the maximum absolute change in net flow between both scenarios was only 0.0046. These results indicate that the ranking remained stable when the survey-derived weighting structure was replaced by equal criterion weights.
Figure 12 provides a criterion-level decomposition of the strengths and weaknesses underlying the survey-weighted ranking. Totoracocha exhibits the most favorable overall balance, particularly across several energy-related and consumption-related criteria. Yanuncay presents an intermediate profile, combining favorable performance in some consumption, surplus, and self-sufficiency indicators with weaker performance in other technical and socioeconomic criteria. San Sebastián shows favorable contributions in criteria such as socioeconomic conditions, technical PV utilization, and emissions reduction; however, these advantages do not compensate for its comparatively weaker performance in several consumption, energy-availability, self-sufficiency, and surplus indicators.
Figure 12. Disaggregation of strengths and weaknesses by area using the PROMETHEE Rainbow.
The stability of the ranking under both weighting scenarios indicates that the ordering of the three study areas is not driven by the relatively small differences among the survey-derived criterion weights. Nevertheless, several indicators share common underlying variables, although they represent different spatial scales and dimensions of PV implementation. Therefore, the PROMETHEE results should be interpreted as a comparative synthesis of multidimensional performance and as a decision-support framework for identifying the differentiated PV implementation profile of each study area, rather than as an absolute hierarchy or as independent causal contributions of individual indicators.

4. Discussion

The results confirm that urban PV characterization should not be limited to estimating the solar resource available on rooftops. Although all three areas exhibit favorable radiation conditions and high levels of theoretical self-sufficiency, the usable potential depends on urban morphology, electricity demand, and the operating capacity of the distribution network. This finding is consistent with studies showing that the configuration of the built environment, usable area, and local technical constraints significantly modify the energy that can ultimately be used [8,10,11].
The highest mean radiation values were recorded for west-facing rooftops in Totoracocha and Yanuncay, at 131.9 and 128.7 kWh/m2, respectively, and for south-facing rooftops in San Sebastián, at 124.7 kWh/m2. The statistical analysis confirmed significant differences among orientations in all three study areas. However, the effect sizes were small, with rooftop orientation explaining only 2.7–4.5% of the observed variability in solar irradiation, while the differences between the highest and lowest mean values ranged from 2.83% to 4.73%. These relatively limited differences are consistent with studies conducted in Cuenca and other equatorial conditions, which report small variations among orientation configurations due to the proximity to the Equator [11,15]. Therefore, although orientation influences the available solar resource, the results suggest that it should be considered primarily as an optimization factor and evaluated together with other rooftop characteristics rather than as a standalone criterion for PV feasibility.
PV energy density introduces a distinction that radiation alone cannot explain. Totoracocha reached 135 kWh/m2·year, followed by Yanuncay at 95 kWh/m2·year and San Sebastián at 70 kWh/m2·year. This variation is related to usable area, building height and concentration, and associated demand. In San Sebastián, the presence of condominiums, hotels, and taller buildings increases consumption and reduces relative rooftop availability per capita. The adjusted density used for this area is supported by the higher concentration of electricity meters per hectare, although this parameter should be interpreted as an approximation of user concentration rather than a direct population measurement.
The theoretical and technical PV potential results presented in this study correspond to the scenario calculated using a constant capacity factor of 0.14. This value was adopted because it is consistent with capacity factors reported for grid-connected PV systems and with experimental results obtained in the context of Cuenca [36,37,45]. Because this parameter is involved from the estimation of building-level generation to transformer-level aggregation and the subsequent network assessment, the results should be interpreted within the conditions defined for this scenario.
Transformer selection constitutes a limitation of the technical assessment. Because the units were selected according to technical criteria and compatibility with CYME 9.2 rather than through probabilistic or stratified sampling, coverage differs among the study areas. The simulated transformers represent between 22.22% and 42.86% of the existing units and between 31.37% and 50.51% of the annual demand in each sector. Therefore, the influence of transformer selection on the aggregated technical results cannot be excluded, and these results should be interpreted as corresponding to the evaluated subsets rather than as statistically representative estimates of the complete transformer population in each area.
The comparison between theoretical potential and the estimated technical PV potential under the evaluated operating scenarios is one of the main contributions of the study. Totoracocha exhibited the highest theoretical potential and area-level surplus but recorded the lowest technical utilization factor, at 15.6%. San Sebastián achieved the highest utilization factor, at 27.2%, whereas Yanuncay obtained the highest technical surplus, at 2.88. These results demonstrate that high theoretical generation availability does not guarantee proportional integration into the grid.
Transformer selection constitutes a limitation of the technical assessment. Units were selected according to technical criteria and compatibility with CYME 9.2 rather than through a probabilistic or stratified sampling design. Consequently, the number and coverage of transformers differ among the study areas, which may influence the aggregated estimated technical PV potential, and, to a lesser extent, the relative indicators derived from these simulations. The results should therefore be interpreted as corresponding to the evaluated subsets. Future work should extend the simulations to a larger proportion of transformers or apply a stratified design to assess the sensitivity of the results to alternative transformer selections.
The simulations showed that integration capacity is mainly constrained by transformers. In the preliminary self-sufficiency scenario, four units exceeded 100% loading, requiring reductions in the proposed PV power. Under peak demand, transformer 22 was already operating at 108.0% and therefore had no margin for new loads, while the surplus associated with transformer 18 was limited to 38 kW to maintain a loading of 98.6%. In contrast, medium-voltage lines showed only small changes, and voltage levels remained close to 1 p.u., with no overvoltage conditions. This behavior is consistent with the literature identifying transformer overloading and reverse power flow as frequent limits on PV hosting capacity [21,22].
PV integration slightly increased voltage levels but did not cause overvoltage at the buses analyzed. This result is consistent with distributed-generation studies reporting moderate improvements or increases in voltage profiles before critical penetration levels are reached [20]. Losses also remained below 2% for most units and therefore did not constitute the dominant technical constraint. Consequently, new PV systems should be planned at the transformer level rather than solely based on aggregate rooftop potential.
The total technically usable surplus was 940,767 kWh/year. Yanuncay accounted for the largest amount, at 452,737 kWh/year, followed by Totoracocha and San Sebastián. As alternative uses, this energy could supply 717 induction cookers, 507 electric vehicles, or produce 17,012.60 kg H2/year. The alternative nature of these applications is essential because all three compete for the same available energy and do not represent simultaneous implementation.
Induction cooking and electric mobility are electrification options with more immediate application. However, the temporal coincidence between solar generation and consumption patterns was not modeled hourly. Actual utilization would therefore require demand management, charging schedules, storage, or tariff signals that shift part of consumption toward solar hours. This requirement is consistent with the mismatch observed in Ecuador between daytime PV generation and the residential peak in the late afternoon and evening [8].
Hydrogen production was analyzed as long-term chemical energy storage. Its advantage lies in converting surplus electricity into a storable resource; however, urban implementation still faces high costs, infrastructure requirements, and regulatory limitations [27,28,46]. Accordingly, it should be interpreted as a future technical alternative rather than an immediate solution for the areas analyzed.
From an environmental perspective, the energy allocated to self-sufficiency could avoid 1022.55 tCO2/year by displacing grid electricity. Alternatively, using the surplus for induction cooking could avoid 642.01 tCO2/year by replacing LPG, whereas its use in electric mobility could avoid 920.75 tCO2/year by replacing gasoline. These estimates correspond to avoided operational emissions. A comprehensive environmental assessment should incorporate the life cycle of modules, inverters, storage systems, and electrolyzers [18].
The multicriteria synthesis reinforces the differences observed among the study areas when technical, energy-related, socioeconomic, and environmental dimensions are considered jointly. Totoracocha maintained the highest overall performance, with Φ = 0.4221, reflecting its favorable balance across PV energy density, energy availability, surplus-related indicators, and self-sufficiency. Yanuncay occupied an intermediate position (Φ = 0.0147), combining favorable performance in several consumption- and surplus-related criteria with lower performance in other technical and socioeconomic indicators. San Sebastián obtained a negative net flow (Φ = −0.4368); however, this result does not imply PV infeasibility, since the area exhibits strengths in socioeconomic conditions, technical PV utilization, and emissions reduction. Instead, the ranking highlights that different urban configurations require differentiated PV implementation strategies rather than a uniform planning approach.
The sensitivity analysis strengthens this interpretation. Replacing the survey-derived weights with equal weights preserved the Totoracocha–Yanuncay–San Sebastián ordering and changed the net flows only slightly, with a maximum absolute variation of 0.0046. Moreover, the separation between Totoracocha and Yanuncay remained nearly unchanged, decreasing only from 0.4074 to 0.4056. Therefore, the observed ranking is stable under the two weighting schemes evaluated and is not driven by the small differences among the survey-derived weights. Nevertheless, the weighting reflects the judgments of 13 respondents and should not be interpreted as a population-wide consensus. In addition, some indicators share underlying variables such as electricity consumption, PV generation, and population; although they represent different analytical scales, their contributions are not fully independent. Consequently, the PROMETHEE ranking should be interpreted as a comparative decision-support synthesis within the adopted indicator framework rather than as an absolute hierarchy among the study areas.
The study has four main limitations. First, the analysis was limited to three study areas selected to represent contrasting urban typologies in Cuenca rather than the entire urban area of the city. Second, the simulations corresponded to specific operating states rather than an annual time series. Third, surplus-energy uses were assessed through equivalent annual balances without modeling hourly coincidence. Fourth, the study did not include a detailed economic assessment of PV-system investment, payback periods, grid-reinforcement costs, or the infrastructure required for surplus-energy utilization. These aspects depend on technology costs, electricity tariffs, compensation mechanisms, and prevailing regulatory conditions and therefore require a dedicated economic assessment. Economic feasibility is consequently identified as a future extension of this research. Future research should integrate hourly profiles, storage, demand control, economic analysis, and scenarios involving transformer expansion or replacement.

5. Conclusions

This study characterized the implementation of solar PV systems in three urban areas selected to represent contrasting urban typologies in Cuenca using technical, energy-related, socioeconomic, and environmental indicators, grid simulations in CYME 9.2, and a PROMETHEE multicriteria synthesis. The results demonstrate that urban PV potential cannot be determined solely from solar irradiation or available area because urban morphology, electricity demand, and grid operating capacity constrain the energy that can be integrated and used.
Rooftop orientation produced statistically significant differences in all three study areas, although it explained only between 2.7% and 4.5% of the variability in solar irradiation. Differences between the highest and lowest mean orientations ranged from 2.83% to 4.73%. Consequently, orientation should be considered as a solar resource optimization factor and evaluated together with roof slope, shading, usable rooftop area, and connection conditions rather than being used as a standalone criterion for determining PV feasibility.
Totoracocha exhibited the highest theoretical potential, a self-sufficiency level of 99.1%, and the highest PV energy density, at 135 kWh/m2·year. Nevertheless, it obtained the lowest technical utilization factor, at 15.6%, because of transformer constraints. Yanuncay achieved the highest technical surplus, at 452,737 kWh/year, and the highest technical-surplus indicator, at 2.88. San Sebastián exhibited the highest technical utilization factor, at 27.2%, although the larger number of transformers analyzed in this area must be considered when interpreting its aggregate technical potential.
The simulations confirmed that transformer loading is the main constraint. Medium-voltage lines maintained low loading levels, and voltages remained close to 1 p.u., without overvoltage. Adjusting the systems that initially exceeded 100% loading enabled the definition of technically admissible potential and prevented the results from depending on overload conditions.
The technical results correspond to estimates obtained under two selected operating conditions using aggregated loads, three-phase inverters operating at unity power factor, and a transformer-loading limit of 100%. Therefore, they do not represent a comprehensive determination of network hosting capacity but rather an approximation of the technically admissible PV potential under the adopted assumptions.
The total technically usable surplus was 940,767 kWh/year. As alternative scenarios, this energy could supply 717 induction cookers, 507 electric vehicles, or produce 17,012.60 kg of green hydrogen per year. These results do not represent simultaneous implementation and require consideration of the temporal coincidence between generation and demand, as well as management, storage, or load-scheduling strategies.
PV energy allocated to self-sufficiency could avoid 1022.55 tCO2/year by displacing grid electricity. Alternatively, surplus energy could avoid 642.01 tCO2/year by replacing LPG or 920.75 tCO2/year by replacing gasoline. These results demonstrate that distributed generation can contribute both to covering electricity demand and to the electrification of end uses.
PROMETHEE II ranked Totoracocha first under the survey-derived weighting scenario, with Φ = 0.4221, followed by Yanuncay with Φ = 0.0147 and San Sebastián with Φ = −0.4368. The net-flow difference of 0.4074 between the first two alternatives indicates a clear overall advantage for Totoracocha under the adopted multicriteria framework. The equal-weight sensitivity analysis preserved the same ordering, with net flows of 0.4189, 0.0133, and −0.4322, respectively, and only minor variations between both scenarios. This stability indicates that the resulting ranking is not driven by the relatively small differences among the survey-derived criterion weights. Nevertheless, the PROMETHEE results should be interpreted as a comparative decision-support synthesis within the adopted indicator framework rather than as an absolute hierarchy among the study areas.
Overall, the proposed approach distinguishes theoretical solar potential from technically integrable potential and provides a replicable decision-support basis for sustainable urban energy planning in intermediate Andean cities. By jointly considering technical, energy-related, socioeconomic, and environmental dimensions, the framework supports the identification of differentiated photovoltaic implementation strategies while accounting for grid constraints, energy self-sufficiency, and potential CO2 emissions reduction. Future research should incorporate hourly simulations, storage, demand response, economic assessment, transformer reinforcement or replacement scenarios, and the analysis of alternative capacity factors through complete database reprocessing.

Author Contributions

Conceptualization, L.M.O.-T., E.R.S.-B. and E.A.B.-E.; methodology, L.M.O.-T., E.R.S.-B. and E.A.B.-E.; software, L.M.O.-T., E.R.S.-B. and C.L.-B.; validation, L.M.O.-T., E.R.S.-B., E.A.B.-E. and C.L.-B.; formal analysis, L.M.O.-T. and E.R.S.-B.; investigation, L.M.O.-T. and E.R.S.-B.; resources, J.T.-Q.; data curation, L.M.O.-T. and E.R.S.-B.; writing—original draft preparation, L.M.O.-T. and E.R.S.-B.; writing—review and editing, L.M.O.-T., E.R.S.-B., E.A.B.-E., J.T.-Q. and C.L.-B.; visualization, L.M.O.-T. and E.R.S.-B.; supervision, E.A.B.-E.; project administration, E.A.B.-E.; funding acquisition, E.A.B.-E. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the Ecuadorian Corporation for the Development of Research and Academia (CEDIA) through project I+D+I-XVIII-2025-007, “Urban Energy Implications”.

Institutional Review Board Statement

Ethical review and approval were waived for this study due to the Regulation of the Human Research Ethics Committee of the University of Cuenca (Code: UC-CU-REG-012-2022), institutional rules restrict CEISH jurisdiction strictly to health- related research, exempting technical energy studies. Article 2 explicitly limits CEISH jurisdiction to four categories: clinical trials, health-related interventions, observational studies with biological samples, and studies involving vulnerable populations or confidential health data.

Data Availability Statement

The original contributions presented in this study are included in the article. Further inquiries can be directed to the corresponding author.

Acknowledgments

The authors thank Corporación Ecuatoriana para el Desarrollo de la Investigación y Academia—CEDIA for the financial support provided for the present research, development, and innovation work through project I+D+I-XVIII-2025-007-IMPLICACIONES ENERGÉTICAS URBANAS. The authors also thank Empresa Eléctrica Regional CENTROSUR C.A. (EERCS) for providing the technical information used in the distribution network analysis and Eng. Ciro Mauricio Larco Barros for his collaboration and technical contributions.

Conflicts of Interest

The authors declare that this study received funding from Ecuadorian Corporation for the Development of Research and Academia (CEDIA). The funder was not involved in the study design, collection, analysis, interpretation of data, the writing of this article or the decision to submit it for publication.

Abbreviations

The following abbreviations are used in this manuscript:
AbbreviationMeaning
ARCONELElectricity Regulation and Control Agency
BIMBuilding information modeling
CEDIAEcuadorian Corporation for the Development of Research and Academia
CENACENational Electricity Operator
CO2Carbon dioxide
CYMEDistribution power system analysis software
EERCSEmpresa Eléctrica Regional CENTROSUR C.A.
PVPhotovoltaic
LPGLiquefied petroleum gas
H2Hydrogen
IQRInterquartile range
LiDARLight detection and ranging
MVMedium voltage
SESSocioeconomic status
PROMETHEEPreference Ranking Organization Method for Enrichment Evaluation
SAMSystem Advisor Model
PVSPhotovoltaic system
GISGeographic information system
EVElectric vehicle

Appendix A. Transformers Considered in the Simulation

Table A1 presents the main characteristics of the transformers selected for the technical assessment of PV integration in CYME 9.2. For confidentiality reasons, only the reference numbering used to organize the analysis is provided.
Table A1. Main characteristics of the transformers are considered in the simulation. Source: Authors’ own elaboration based on information provided by EERCS.
To quantify the scope of the transformer selection, Table A2 summarizes the number of transformers included in the simulations and the associated annual-demand coverage for each study area.
Table A2. Coverage of the transformer subsets used in the CYME 9.2 simulations.
As shown in Table A2, transformer coverage ranged from 22.22% to 42.86%, while the analyzed units represented between 31.37% and 50.51% of the total annual demand of each study area. These differences result from the technical and modeling criteria applied during transformer selection rather than from an equal or probabilistic sampling design. Consequently, the CYME results characterize the selected transformer subsets and should not be interpreted as statistically representative estimates of the complete transformer population in each area.
Twenty participants with knowledge related to the energy and photovoltaic fields were invited to participate in the survey, and 13 valid responses were obtained. Each of the twelve indicators was rated on a five-point importance scale, ranging from 1 (very low importance) to 5 (very high importance). The individual responses were anonymized and are presented in Table A3. These data were used to calculate the mean importance scores, sample variances, normalized criterion weights, and the internal consistency of the response matrix.
Table A3. Individual survey responses used to derive the PROMETHEE criterion weights.
Table A4 presents the complete decision matrix used in the PROMETHEE analysis. The matrix contains the values of the twelve evaluation criteria for San Sebastián, Totoracocha, and Yanuncay, together with their corresponding units and preference directions. The same decision matrix and preference directions were maintained in both the survey-derived and equal-weight scenarios used for the sensitivity analysis.
Table A4. Complete decision matrix and configuration of the criteria used in PROMETHEE.

References

  1. Criollo Enríquez, R.F.; Guaillas Domínguez, D.P.; Correa, D.O. Evolución tecnológica de la generación solar fotovoltaica: Una revisión de la literatura en la última década. Rev. Tecnol.-ESPOL 2024, 36, 13–31. [Google Scholar] [CrossRef] [Scilit]
  2. Tapia, M.; Ramos, L.; Heinemann, D.; Zondervan, E. Power to the city: Assessing the rooftop solar photovoltaic potential in multiple cities of Ecuador. Phys. Sci. Rev. 2023, 8, 2285–2319. [Google Scholar] [CrossRef] [Scilit]
  3. ARCONEL. Atlas del Sector Ecuatoriano 2024. 2024. Available online: https://arconel.gob.ec/publicaciones-estadistica-del-sector-electrico-2/ (accessed on 19 June 2026).
  4. ARCONEL. Marco Normativo de la Generación Distribuida para el Autoabastecimiento de Consumidores Regulados de Energía Eléctrica. Regulación Nro. ARCONEL-005/24 (Codificada). Agencia de Regulación y Control de Electricidad: Quito, Ecuador, 2024. Available online: https://www.gob.ec/regulaciones/arconel-00524-codificada-marco-normativo-generacion-distribuida-autoabastecimiento-consumidores-regulados-energia-electrica (accessed on 19 June 2026).
  5. Aslani, M.; Seipel, S. Automatic identification of utilizable rooftop areas in digital surface models for photovoltaics potential assessment. Appl. Energy 2022, 306, 118033. [Google Scholar] [CrossRef] [Scilit]
  6. Travesset-Baro, O.; Vilella, M.; Borges, P. Hacia la autosuficiencia energética en las ciudades. análisis del potencial solar fotovoltaico a escala urbana en el Principado de Andorra. CienciAmérica 2021, 10, 25–40. [Google Scholar] [CrossRef] [Scilit]
  7. Caamaño Martín, E.; Díaz-Palacios, S. Potencial Solar Fotovoltaico de las Cubiertas Edificatorias de la Ciudad de Vitoria-Gasteiz-CEA-Vitoria-Gasteiz.org. Available online: https://cea.vitoria-gasteiz.org/portal/es/w/potencial-solar-fotovoltaico-de-las-cubiertas-edificatorias-de-la-ciudad-de-vitoria-gasteiz (accessed on 19 June 2026).
  8. Tapia, M.; Ramos, L.; Heinemann, D.; Zondervan, E. Evaluación del potencial fotovoltaico en tejados en el cantón Quito. Perfiles 2023, 1, 47–56. [Google Scholar] [CrossRef] [Scilit]
  9. Idrovo-Macancela, A.; Velecela-Zhindón, M.; Barragán-Escandón, A.; Zalamea-León, E.; Mejía-Coronel, D. GIS-based assessment of photovoltaic solar potential on building rooftops in equatorial urban areas. Heliyon 2025, 11, e41425. [Google Scholar] [CrossRef] [Scilit] [PubMed]
  10. Zalamea, E.; Barragán-Escandón, A. Revisión conjunta de fuentes primordiales para autoabastecimiento energético urbano e incidencia solar como principal fuente, en contexto de ciudad ecuatorial-andina. ACI Av. Cienc. Ing. 2020, 12, 72–93. [Google Scholar] [CrossRef] [Scilit]
  11. Zalamea-León, E.; Mena-Campos, J.; Barragán-Escandón, A.; Parra-González, D.; Méndez-Santos, P. Urban photovoltaic potential of inclined roofing for buildings in heritage centers in equatorial areas. J. Green Build. 2018, 13, 45–69. [Google Scholar] [CrossRef] [Scilit]
  12. Zambrano-Asanza, S.; Zalamea-León, E.F.; Barragán-Escandón, E.A.; Parra-González, A. Urban photovoltaic potential estimation based on architectural conditions, production-demand matching, storage and the incorporation of new eco-efficient loads. Renew. Energy 2019, 142, 224–238. [Google Scholar] [CrossRef] [Scilit]
  13. Jacobson, M.Z.; Jadhav, V. World estimates of PV optimal tilt angles and ratios of sunlight incident upon tilted and tracked PV panels relative to horizontal panels. Sol. Energy 2018, 169, 55–66. [Google Scholar] [CrossRef] [Scilit]
  14. Ruperto, R.F.; Luis, P.-B.; Ángel, P.V. Determination of Optimal Tilt and Orientation Angles for Fixed Photovoltaic Systems Using a Three-Dimensional Vector Analysis of Direct Normal Irradiance in Equatorial Regions. Solar 2025, 5, 55. [Google Scholar] [CrossRef] [Scilit]
  15. Izquierdo Torres, I.F.; Pacheco-Portilla, M.G.; Gonzalez-Morales, L.G.; Zalamea-León, E.F. Simulación fotovoltaica considerando parámetros de integración en edificaciones. Ingenius 2019, 21, 21–31. [Google Scholar] [CrossRef] [Scilit]
  16. Scolari, B.S.; Do Nascimento, D.E.; De Souza, M.; Strauhs, F.d.R. Impacto da pandemia de COVID-19 na micro e minigeração distribuída fotovoltaica no Brasil: Seleção e análise de indicador representativo. Rev. Bras. Ciênc. Ambient. 2022, 57, 397–408. [Google Scholar] [CrossRef] [Scilit]
  17. Calvo-Bascones, P.; Martín-Martínez, F. Indicators for suitability and feasibility assessment of flexible energy resources. Appl. Energy 2024, 372, 123834. [Google Scholar] [CrossRef] [Scilit]
  18. Fares, H.; Lobaccaro, G.; Gazbour, N.; Rasmussen, F.N.; Chèze, D.; Le Pierrès, N.; Wurtz, E. A methodology for assessing environmental impact of building integrated PV in low carbon footprint electricity generation context. Energy Build. 2025, 329, 115219. [Google Scholar] [CrossRef] [Scilit]
  19. Fatima, S.; Püvi, V.; Lehtonen, M. Review on the PV Hosting Capacity in Distribution Networks. Energies 2020, 13, 4756. [Google Scholar] [CrossRef] [Scilit]
  20. Stecanella, P.A.J.; Vieira, D.; Vasconcelos, M.V.L.; Ferreira Filho, A.D.L. Statistical Analysis of Photovoltaic Distributed Generation Penetration Impacts on a Utility Containing Hundreds of Feeders. IEEE Access 2020, 8, 175009–175019. [Google Scholar] [CrossRef] [Scilit]
  21. Majeed, I.B.; Nwulu, N.I. Impact of Reverse Power Flow on Distributed Transformers in a Solar-Photovoltaic-Integrated Low-Voltage Network. Energies 2022, 15, 9238. [Google Scholar] [CrossRef] [Scilit]
  22. Córdova-Guamanquispe, C.-G.; Marrero-Ramírez, S.; Pujos-Calapiña, D. Impacto de la generación distribuida mediante sistemas fotovoltaicos de autoconsumo en circuitos urbanos. INGENIAR 2025, 8, 187–204. [Google Scholar]
  23. Liao, W.; Kim, C.; Xiao, Y.; Kim, H.; Hong, T.; Yin, S.; Heo, Y. Quantifying Photovoltaic surplus at an urban scale: A case study in Seoul. Energy Build. 2023, 298, 113523. [Google Scholar] [CrossRef] [Scilit]
  24. Goldsworthy, M. Solar PV self-consumption trends in Australia. Sol. Energy Adv. 2025, 5, 100119. [Google Scholar] [CrossRef] [Scilit]
  25. Nolivos, I.; Molina, E.; Bejarano, L.; Valarezo, A. Importancia del Subsidio Eléctrico Para las Cocinas de Inducción y su Efecto en la Salud, la Eficiencia Energética y el Ahorro de Recursos, Para los Ecuatorianos; Clean Cooking Lab: Quito, Ecuador, 2021. [Google Scholar]
  26. Martínez-Gómez, J.; Ibarra, D.; Villacis, S.; Cuji, P.; Cruz, P.R. Analysis of LPG, electric and induction cookers during cooking typical Ecuadorian dishes into the national efficient cooking program. Food Policy 2016, 59, 88–102. [Google Scholar] [CrossRef] [Scilit]
  27. Posso, F.; Sánchez, J.; Espinoza, J.L.; Siguencia, J. Preliminary estimation of electrolytic hydrogen production potential from renewable energies in Ecuador. Int. J. Hydrogen Energy 2016, 41, 2326–2344. [Google Scholar] [CrossRef] [Scilit]
  28. Pelaez-Samaniego, M.R.; Riveros-Godoy, G.A.; Torres Contreras, S.; Garcia-Perez, M.; García-Renté; Albornoz-Vintimilla, C.E. Hidrógeno Electrolítico: Perspectivas de Producción y Uso en Ecuador. Available online: https://www.researchgate.net/publication/286756143_Hidrogeno_electrolitico_perspectivas_de_produccion_y_uso_en_Ecuador (accessed on 20 June 2026).
  29. Torres Quezada, J.E. Implicaciones Energéticas de la Transformación Urbana en Ciudades Intermedias: Caso de Estudio Cuenca-Ecuador; Universidad de Cuenca: Cuenca, Ecuador, 2025. [Google Scholar]
  30. Salazar-Vintimilla, A. Cuenca Cómo Vamos. Available online: https://revistas.uazuay.edu.ec/index.php/ccv (accessed on 21 June 2026).
  31. Ministerio de Energía y Minas. Plan Maestro de Electricidad 2023–2032. 2023. Available online: https://www.celec.gob.ec/transelectric/plan-maestro-de-electricidad-2012-2022/ (accessed on 20 June 2026).
  32. IAEA. Energy Indicators for Sustainable Development: Guidelines and Methodologies; IAEA: Vienna, Austria, 2005; Available online: https://sdgs.un.org/publications/energy-indicators-sustainable-development-guidelines-and-methodologies-16969 (accessed on 20 June 2026).
  33. Taco, J.; Tipán, L. Metodología para la determinación de indicadores de Eficiencia Eléctrica en la Zona Residencial. Rev. Téc. Energ. 2020, 16, 70–90. [Google Scholar] [CrossRef] [Scilit]
  34. INEC. Encuesta de Estratificacion del Nivel Socioeconomico. Available online: https://www.ecuadorencifras.gob.ec/ (accessed on 20 June 2026).
  35. CENACE. Factor de Emisión de CO2 del Sistema Nacional Interconectado de Ecuador: Informe 2025; CENACE: Mejía, Ecuador, 2025. [Google Scholar]
  36. Attari, K.; Elyaakoubi, A.; Asselman, A. Performance analysis and investigation of a grid-connected photovoltaic installation in Morocco. Energy Rep. 2016, 2, 261–266. [Google Scholar] [CrossRef] [Scilit]
  37. Mogrovejo-Narvaez, M.; Barragán-Escandón, A.; Zalamea-León, E.; Serrano-Guerrero, X. Barriers to the Implementation of On-Grid Photovoltaic Systems in Ecuador. Sustainability 2024, 16, 9466. [Google Scholar] [CrossRef] [Scilit]
  38. Zalamea-León, E.; Ochoa-Correa, D.; Sánchez-Castillo, H.; Astudillo-Flores, M.; Barragán-Escandón, E.A.; Ordoñez-Castro, A. Expectations Versus Reality: Economic Performance of a Building-Integrated Photovoltaic System in the Andean Ecuadorian Context. Buildings 2025, 15, 2493. [Google Scholar] [CrossRef] [Scilit]
  39. Villa-Ávila, E.; Arévalo, P.; Ochoa-Correa, D.; Villa-Ávila, M.; Sempértegui-Moscoso, E.; Jurado, F. A New Methodology for Estimating the Potential for Photovoltaic Electricity Generation on Urban Building Rooftops for Self-Consumption Applications. Smart Cities 2024, 7, 3798–3822. [Google Scholar] [CrossRef] [Scilit]
  40. Eaton. CYME Power Engineering Software. 2026. Available online: https://www.eaton.com/us/en-us/software/utility-solutions/cyme-power-engineering-software-solutions.html#sortCriteria=%40p_navigation_title%20ascending%2C%40page_title%20ascending%2C%40title%20ascending&enableQuerySyntax=true&cq=%40sub_category_id%3D%3D%22cyme-power-engineering-solutions%22%20AND%20%40country%3D%22us%22%20AND%20%40language%3D%22en_US%22 (accessed on 20 June 2026).
  41. Gallo Álvarez, C.F. Análisis de la Incidencia de la Incorporación Progresiva de Cocinas de Inducción en la Calidad de la Energía de la Red Eléctrica de Sub-Distribución. 2023. Available online: https://bibdigital.epn.edu.ec/handle/15000/25157 (accessed on 21 June 2026).
  42. Zalamea-León, E.; Barragán-Escandón, A. Indicadores de captación fotovoltaica y solar térmica para ciudades ecuatoriales andinas, para demandas de núcleos familiares y consumos urbanos. ÑAWPAY Rev. Téc. Tecnol. 2019, 1, 5. [Google Scholar] [CrossRef] [Scilit]
  43. Ochoa-Correa, D.; Sempértegui-Moscoso, E.; Villa-Ávila, E.; Arévalo, P.; Espinoza, J.L. PV Solar-Powered Electric Vehicles for Inter-Campus Student Transport and Low CO2 Emissions: A One-Year Case Study from the University of Cuenca, Ecuador. Sustainability 2025, 17, 7595. [Google Scholar] [CrossRef] [Scilit]
  44. Puma-Benavides, D.S.; Cevallos-Carvajal, A.S.; Masaquiza-Yanzapanta, A.G.; Quinga-Morales, M.I.; Moreno-Pallares, R.R.; Usca-Gomez, H.G.; Murillo, F.A. Comparative Analysis of Energy Consumption between Electric Vehicles and Combustion Engine Vehicles in High-Altitude Urban Traffic. World Electr. Veh. J. 2024, 15, 355. [Google Scholar] [CrossRef] [Scilit]
  45. Zalamea-León, E.; Jaramillo-Arevalo, S.; Vera-Tandazo, R.; Chica-Guayacundo, Á.; Tapia-Sacasari, J.; Barragán-Escandón, A.; Ordóñez-Castro, A. Methodology for the Integration of Photovoltaics in Buildings for Inclusion in Territorial and Urban Planning with Low-Technology, Affordable Instruments. Urban Sci. 2026, 10, 154. [Google Scholar] [CrossRef] [Scilit]
  46. Cevallos-Escandón, A.; Barragan-Escandón, E.A.; Zalamea-León, E.; Serrano-Guerrero, X.; Terrados-Cepeda, J. Assessing the Feasibility of Hydrogen and Electric Buses for Urban Public Transportation using Rooftop Integrated Photovoltaic Energy in Cuenca Ecuador. Energies 2023, 16, 5569. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.