Next Article in Journal
EAF Slag Aggregate in Roller-Compacted Concrete Pavement: Effects of Delay in Compaction
Next Article in Special Issue
Consumers’ Willingness to Pay for Net-Zero Energy Apartment in South Korea
Previous Article in Journal
Pessimism on the Food Front
Previous Article in Special Issue
Phase Change Material (PCM) Application in a Modernized Korean Traditional House (Hanok)
Article Menu
Issue 4 (April) cover image

Export Article

Open AccessArticle
Sustainability 2018, 10(4), 1121; https://doi.org/10.3390/su10041121

Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea

1
Sustainable Building Research Center, Hanyang University, 55 Hanyangdaehak-ro, Sangrok-gu, Ansan-si 15588, Gyeonggi-do, Korea
2
School of Architecture & Architectural Engineering, Hanyang University, 55 Hanyangdaehak-ro, Sangrok-gu, Ansan-si 15588, Gyeonggi-do, Korea
3
Research Center of Technology, ALU ENC Co., 10, Baekjegobun-ro 9-gil, Songpa-gu 05562, Seoul, Korea
*
Author to whom correspondence should be addressed.
Received: 22 February 2018 / Revised: 30 March 2018 / Accepted: 31 March 2018 / Published: 9 April 2018
Full-Text   |   PDF [83443 KB, uploaded 3 May 2018]   |  

Abstract

This study compares the impact of the recently developed electrochromic glazing technology on load reduction by comparing it with the double-glazing and shading devices that are sold commercially for high-rise residential buildings in Korea. These buildings are similar to large office buildings in terms of their high window-to-wall ratio. The energy consumption of such buildings was simulated using an analytical model of a high-rise residential building. The patterns between the heating and cooling loads were found to be similar to that of office buildings, in that the cooling load was considerably higher than the heating load. This study hypothesizes that the load reduction performance of electrochromic glazing with variable solar control and high solar radiation rejection is superior to that of existing double-glazing products and shading devices. This hypothesis was tested by analyzing the cooling and heating loads of buildings with different types of double glazings. Bleached electrochromic glazing exhibited lower transmittance than colored glass double glazing, low-e double glazing, and double glazing with a shading device, and is thus not effective in reducing heating load. Colored electrochromic glazing provided higher solar radiation rejection than colored glass double glazing and low-e double glazing, and thus is effective in reducing cooling load. View Full-Text
Keywords: electrochromic glazing; optical properties; heating and cooling loads; high-rise residential building; curtain wall; EnergyPlus electrochromic glazing; optical properties; heating and cooling loads; high-rise residential building; curtain wall; EnergyPlus
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited (CC BY 4.0).
SciFeed

Share & Cite This Article

MDPI and ACS Style

Oh, M.; Tae, S.; Hwang, S. Analysis of Heating and Cooling Loads of Electrochromic Glazing in High-Rise Residential Buildings in South Korea. Sustainability 2018, 10, 1121.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Sustainability EISSN 2071-1050 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top