Abstract
Urban areas face increasing challenges related to heat stress and urban heat islands, necessitating effective strategies for microclimate regulation and thermal comfort enhancement. This study investigates the cooling effect of three tree species, Ficus retusa, Ficus benjamina and Fraxinus spp. (Ash trees), on urban microclimates and thermal comfort in downtown Annaba, Algeria, during the summer. The methodology comprises two complementary methods. First, field measurements of air temperature (Ta), relative humidity (RH), and wind speed (Ws) were recorded hourly from 9 a.m. to 9 p.m. Second, collected data was inputted into the ENVI-met microclimate model to simulate various urban canopy scenarios. Microclimate variations, including air temperature (Ta), mean radiant temperature (Tmrt), relative humidity, wind speed, and the Physiological Equivalent Temperature (PET) index, were computed over a 13 h period, from 9 a.m. to 9 p.m., to examine the cooling effect of each species and their impact on outdoor thermal comfort. The results demonstrate the notable cooling effect of Ficus species and Fraxinus spp. with Ficus species generally exhibiting larger reductions in air temperature (0.9 °C to 2 °C) and PET index (7.3 °C to 7.7 °C), and higher increases in relative humidity (5.6% to 6.8%) compared to Ash trees.
1. Introduction
Urban areas across the globe are facing significant challenges due to rising temperatures and increased frequency of heatwaves, exacerbated by the phenomenon known as the urban heat island (UHI) effect [1,2]. This effect, characterized by higher temperatures in urban areas compared to their rural surroundings, is driven by a confluence of factors [3,4]. The prevalence of impervious surfaces such as asphalt and concrete, coupled with dense populations and the reduction in natural landscapes and vegetation, leads to this phenomenon [5,6,7]. This results in urban dwellers experiencing more thermal discomfort, higher energy use for cooling, and negative health effects, particularly during extreme heatwaves [8,9].
Addressing these challenges is crucial for enhancing the sustainability and liveability of urban environments, and the urgency of addressing UHI effects is further intensified by the broader context of climate change [10]. As global temperatures rise, cities are experiencing more frequent and severe heatwaves, which exacerbate the existing thermal stress caused by the UHI effect [11]. Climate change not only increases the baseline temperatures but also alters precipitation patterns, leading to drier conditions that can reduce the cooling benefits of urban vegetation [12,13]. This interplay between urbanization and climate change creates a pressing need for effective mitigation strategies to protect urban populations and infrastructure from escalating thermal stress.
In this context, urban forestry has emerged as a critical strategy for mitigating the UHI effect and improving thermal comfort in cities [14,15]. Trees offer multiple environmental benefits that are particularly valuable in urban settings. Through shading, trees reduce the amount of solar radiation that reaches buildings and pavements, thereby lowering surface temperatures [16,17]. Additionally, the process of transpiration, whereby trees release water vapor through their leaves, cools the air, contributing to lower ambient temperatures [18]. The cumulative effect of these processes can notably alleviate the heat burden in urban areas, making cities more resilient to climate variability and extreme weather conditions.
The selection and management of tree species within urban environments are crucial to maximizing these advantages [19]. Different tree species exhibit varying capabilities in terms of canopy density, leaf area, transpiration rates, and other physiological attributes that influence their cooling effects [20]. Additionally, the adaptability of tree species to local climate conditions and their resistance to urban stressors such as pollution and limited soil space are important considerations [21,22]. Therefore, understanding how different tree species contribute to urban cooling helps prioritize effective species in urban forestry. Furthermore, the tree population in a given area often consists of trees of varying ages due to a combination of ecological, environmental, and human factors. Ecologically, natural processes such as seed dispersal, germination, and succession result in a mix of young saplings and mature trees within the same habitat [23]. Environmental factors and human activities create diverse tree age structures, which are vital for ecosystem resilience, continuous ecological services, and biodiversity. Understanding these reasons helps in accurately modeling and managing urban and natural tree populations [24,25].
Annaba City, a prominent urban center in Algeria, provides a valuable case study for investigating the impact of urban trees on microclimate and thermal comfort. Influenced by the broader effects of global climate change, recent studies have shown that Annaba City is deviating from its traditional Mediterranean climate towards increased aridity. Over a span of 30 years, researchers have documented notable climatic shifts, indicating a trend towards drier conditions [26]. Additionally, Annaba City is notably affected by the UHI phenomenon, with an intensity exceeding 6 °C [26,27]. Although tree-planting and landscape enhancement projects have been implemented in several public spaces, particularly the integration of urban vegetation within major public spaces such as Revolution and El-Bouni Plazas [28], these interventions are generally undertaken as part of urban improvement projects rather than within a comprehensive urban forestry strategy or urban resilience framework. In practice, the selection and planting of urban trees in Annaba, as in many Algerian cities, are primarily based on the availability of planting space and nursery stock, with a growing preference for palm trees in recent urban development projects, rather than on scientific, ecological, or microclimatic performance criteria. Furthermore, the management of urban green spaces is governed by Law No. 07-06 of 13 May 2007 concerning the management, protection, and development of green spaces, while national urban policies remain largely oriented towards disaster risk prevention and management under Laws No. 04-20 of 25 December 2004 and No. 24-04 of 26 February 2004, rather than towards urban resilience and climate adaptation strategies. Consequently, the cooling performance of existing urban tree species has not yet been systematically assessed to support evidence-based species selection for mitigating urban heat.
Urban trees’ ability to cool their surroundings varies notably with local climate conditions. For instance, in hotter, arid climates, tree species with lower hydraulic conductance may have limited transportational cooling capacity, impacting their overall effectiveness in heat mitigation [29,30]. The present study aims to evaluate the effectiveness of two tree species, Ficus and Fraxinus, in cooling the urban environment of Annaba. These species were selected from the city’s existing flora, considered an important natural heritage inherited from the colonial era. The aim of quantifying their influence on the urban microclimate and outdoor thermal comfort is to provide scientific evidence to support future species selection and contribute to the development of climate-responsive urban greening strategies in Annaba. Accordingly, this study addresses the following research question: Can the cooling performance of the dominant urban tree species provide evidence to improve tree selection practices for mitigating the urban heat island effect in Annaba? This study is based on the hypothesis that Ficus species and Fraxinus spp. exhibit notably different microclimatic cooling performances owing to their contrasting morphological and physiological characteristics and that identifying the more effective species can contribute to evidence-based urban greening strategies. By analyzing the microclimatic and thermal comfort impacts of these trees, this study seeks to provide clear insights into their optimal selection and management in urban spaces.
2. Research Background
2.1. Study Site
This study was conducted in Annaba, a Mediterranean and African seaport city located in the northeastern region of Algeria. Annaba, with 1,000,000 for its metropolitan area, stands as the third-largest city and the principal industrial hub within Algeria [31]. The focus of our investigation lies within the historical downtown area of the city, which dates back to the French colonial era and is renowned for its bustling commercial and trading activities. The study area spans a total surface area of 39.26 hectares, encompassing diverse land uses and features. The study site is approximately five minutes from the city’s harbor. See Figure 1. From an urban planning perspective, this historic area is characterized by a straightforward geometric street layout, featuring three primary thoroughfares extending from El-Hattab midpoint to the Revolution Plaza, as presented in Figure 1. These streets, alongside secondary pathways, facilitate efficient navigation throughout the area with a percentage of 35% from the total surface area. Predominantly comprising medium-rise structures ranging from one to three stories, the buildings in this locale predominantly accommodate commercial enterprises on their ground floors, while upper levels serve a hybrid function encompassing residential and service-oriented uses, collectively occupying 58.9% of the overall surface area. Notably, green spaces constitute a modest percentage of 6%, amounting to 2.4 hectares within the overall area. Among these green spaces, Revolution Plaza emerges as the most prominent, covering an expanse of 1.6 hectares, characterized by lush vegetation. Similarly, Alexis Lambert Square, occupying 0.55 hectares, also features ample greenery, contributing to the overall verdant ambiance of the area. Conversely, Theatre Square, encompassing 0.14 hectares, notably lacks notable vegetation, indicating a potential disparity in green space distribution within the study area. Subsequently, the research focus was refined to encompass the Theatre Square and three specific streets, namely Ibn Khaldoun Street, Cheikh Laarbi Tebessi Street, and Emir Abdelkader Street. The land-use statistics and surface area percentages were based on urban planning documents and data provided by the local authorities of Annaba.
Figure 1.
Study site. Geographical context and study area.
2.2. Arboriculture of Annaba City
Annaba city has inherited a notable urban tree inventory from the French colonial era. The urban landscape, particularly within built-up areas, has witnessed a notable emphasis on urban vegetation, with specific attention directed towards certain species of urban trees and plants [32,33]. For instance, the city’s largest urban forest located within the Christian burial ground, characterized by expansive coniferous cover spanning approximately 6.5 hectares. Exhibiting a discernible hierarchy, public gardens throughout the city are predominantly adorned with various species of Ficus species; Laurel Fig, Weeping Fig, and other flowering specimens, exemplified by the renowned Garden Edough. Transitioning to plazas and squares, a conspicuous utilization of venerable Ficus species, renowned for their climatic significance and grandeur, is evident. Notably, Revolution Plaza emerges as a paramount outdoor venue within the city, accommodating diverse activities while serving as an urban oasis owing to its extensive shaded canopy. Moreover, colonial-era neighborhoods are characterized by designations based on prominent tree species, exemplified by locales such as “Les Frênes” denoting an area adorned with Ash trees. This residential enclave comprises dwellings surrounding a central garden replete with Ash trees, thereby justifying the appellation of the locale. Similarly, neighborhoods such as “Caroubier” signifying the prevalence of Carob trees and “Saffron” denoting the Saffron trees adorning its environs further underscore the deliberate integration of arboreal elements within the urban fabric. Such nomenclatural conventions not only serve to commemorate the botanical legacy of the city’s past but also reflect a conscious urban planning ethos centered on the harmonious coexistence of nature and built environments. By aligning these practices with concurrent developments in France during the same period, particularly the emphasis placed on green spaces in Paris transformation, it becomes evident that the interest in urban trees within Annaba, as a French colonized city, signifies more than mere environmental stewardship. Rather, it underscores a profound appreciation for the aesthetic and ecological functions such as oxygenation of built-up areas and reduction in pollutants. In summarizing the key tree species and their characteristics derived from the arboriculture of Annaba city, four prominent species stand out: Conifer trees, Ficus species, Ash trees, and Carob trees. Botanical details of these species are shown in Table 1.
Table 1.
Features of main tree species derived from the arboriculture of Annaba city.
3. Materials and Methods
This study investigates the cooling effect of various tree species on the urban microclimate and thermal comfort levels at a fine scale within downtown Annaba during the summer. Specifically, it focuses on evaluating the cooling effect of Ficus and Ash trees across four distinct urban sequences. These sequences were strategically selected to represent a diverse range of urban environments, with particular attention paid to areas characterized by high activity and attendance. Notably, three urban sequences situated along main thoroughfares were selected: Sequence one (S1) along Cheikh Laarbi Tebessi Street, Sequence two (S2) along Ibn Khaldoun Street, and Sequence three (S3) along Emir Abdelkader Street, each offering unique characteristics for analysis. Additionally, Theatre Square (S4) was included as a pivotal location due to its significance within the urban landscape. The scientific methodology includes two main phases. First, microclimate data was collected through field measurements at multiple locations within downtown Annaba during summer 2023, recording air temperature, relative humidity, and wind speed from 9 a.m. to 9 p.m. within each of the aforementioned sequences. The instrumentation utilized for data collection included high-precision devices for measuring air temperature and relative humidity, as well as anemometers for assessing wind speed. Data were recorded hourly to capture temporal variations. Second, the collected microclimate data were used to simulate different scenarios for the urban sequences using the ENVI-met model. Three scenarios were created by manipulating tree species within the ENVI-met model, including the current design devoid of urban trees. Each scenario, therefore, represents a unique combination for the urban canopy. Subsequently, microclimate variations alongside the PET index were computed over a 13 h period from 9 a.m. to 9 p.m., enabling the quantification of thermal outdoor comfort levels across various sequences. Figure 2 presents the scientific methodology of this study.
Figure 2.
Scientific methodology.
3.1. Field Measurements
Field measurements were conducted in downtown Annaba during the summer overheating period of 2023, specifically from 5 to 7 July and 14 to 16 August. The mean times for sunrise and sunset during the measurement days were as follows: for 5 to 7 July, sunrise occurred at approximately 05:17 and sunset at 19:50; for 14 to 16 August, sunrise was at approximately 05:46 and sunset at 19:20. The investigation encompassed the measurement of air temperature (Ta), relative humidity (RH), and wind speed (Ws) at four distinct locations within the aforementioned sequences, denoted as S1 to S4, strategically situated within the study area. The measurement points were selected to represent different urban configurations within the study area, considering variations in street geometry, building arrangement, pedestrian activity, and solar exposure. S1, S2, and S3 correspond to the three main streets (Cheikh Laarbi Tebessi Street, Ibn Khaldoun Street, and Emir Abdelkader Street), while S4 corresponds to Theatre Square. Since the investigated urban sequences were located in different areas, measurements were conducted on different dates. A design day was chosen from these measurements for each sequence, wherein a design day signifies a day exhibiting similar conditions of high exposure to the sun, clear skies, and high thermal stress. Data collection occurred between 9 a.m. and 9 p.m. utilizing a portable multifunctional device, namely the “Air Quality Monitoring Particle Counter PCE-MPC 20 (PCE Instruments, Meschede, Germany),” alongside an anemometer, the PROVA AVM-07 Anemometer (PROVA Instruments Inc., Taipei, Taiwan),” positioned at a height of 2.2 m. Prior to field measurements, both instruments were calibrated following the manufacturers’ protocols. The PCE-MPC 20 was checked using its built-in calibration function and verified against a reference aerosol source to ensure accurate particle size and concentration readings. The PROVA AVM-07 Anemometer was calibrated in a controlled indoor environment against a standard reference fan to confirm air velocity measurements, with zero-adjustment performed before each data collection session. Table 2 delineates the instruments specifications.
Table 2.
Specification and operating conditions of the microclimate measurements.
3.2. Physiological Equivalent Temperature (PET) Index
The PET index combines various meteorological parameters such as air temperature, humidity, wind speed, and radiation into a single value. The index, developed by Mayer and Höppe (1987), was selected as the thermal comfort indicator in this study due to its wide application in urban climate research and its ability to translate complex meteorological variables into a single, easily interpretable value for human thermal perception [34]. It is particularly valuable in assessing outdoor thermal comfort and evaluating the impacts of climate change [35,36]. The PET index typically categorizes thermal comfort levels into different ranges based on the perceived level of comfort or stress experienced by individuals. These categories may vary slightly depending on the specific PET model or classification system used but commonly include the presented categories in Table 3. The PET index was computed using the microclimate model ENVI-met, which enabled the simulation of thermal conditions over a 13 h period from 9 a.m. to 9 p.m. While ENVI-met has been extensively used in international studies, few [28] have examined the thermal performance of heritage urban tree species in North African coastal cities. Our study fills this gap by focusing on Ficus species and Fraxinus spp. in Annaba, Algeria, linking simulation outputs to both cultural heritage preservation and climate-change adaptation planning.
Table 3.
Summer PET index categorizes [34].
3.3. Microclimate Simulations
Our investigation utilized the ENVI-met microclimate model, specifically employing the licensed version V5.6.1, Winter 23. The aim was to examine the cooling impact of Ficus species (Ficus retusa and Ficus benjamina) and Fraxinus spp. (Ash trees) across downtown Annaba at a fine scale. To achieve this, a series of microclimate simulations were conducted across four distinct urban sequences denoted as S1 to S4, including the Theatre Square, during the summer overheating period of 2023, specifically from 5 to 7 July and 14 to 16 August. Notably, all sequences were characterized by the absence of urban trees. The rationale for examining these sequences stemmed from the urban design principles observed in the renowned Revolution Plaza, which emphasized the integration of surrounding buildings and the strategic placement of trees along its expanse. Sequences S1 to S3 represented limited areas, each approximately 2500 m2 in surface area, with dimensions of 50 m × 50 m × 20 m under the urban canopy. Sequence S4, the Theatre Square, encompassed a larger area measuring approximately 3750 m2 with dimensions of 75 m × 50 m × 20 m. All sequences underwent simulation for three scenarios: the first scenario depicted the sequences with their current design devoid of any urban trees. The second scenario simulated the urban design of the sequences with the inclusion of Ficus species, either Ficus retusa or Ficus benjamina, or both, based on the layout and utilization of each sequence, while the third scenario simulated the sequences with Ash trees (Fraxinus spp.). The detailed framework of the simulation process including the input data and the initial settings are presented in Table 4.
Table 4.
Simulation framework of four sequences in downtown Annaba.
The modeling process of various scenarios for four sequences encompasses five main steps, as illustrated in Figure 3. The first step involves generating the settings for each sequence using the “space” functionality within the Headquarter of the ENVI-met program. In the second step, a simulation file is created by inputting data such as date, time, location, and meteorological parameters through the “Envi-guide” functionality. The third step entails launching the simulation using the “Envi-core” tool, with the operation duration for each sequence ranging from 1 to 3 h. In the fourth step, the integrated “Biomet” tool is employed to calculate the PET index for each simulated scenario. Finally, in the fifth step, all outputs are visualized using the “Leonardo” functionality, which converts atmospheric files into 2D maps, supported with Xls files on demand. The output data derived from these simulations, including air temperature (Ta), mean radiant temperature (Tmrt), relative humidity (RH), and wind speed (Ws), alongside the Physiological Equivalent Temperature (PET) index, were instrumental in examining the cooling effect of different tree species on the variations in urban microclimate and thermal comfort levels across the diverse urban sequences under investigation. Such understandings are of considerable significance for informing urban planning endeavors and tree management policies aimed at augmenting outdoor comfort in Annaba city. Overall, our methodology has consistently demonstrated its reliability, particularly through the utilization of the Envi-met model in microclimate and outdoor thermal comfort studies, as evidenced by a large number of studies [7,37,38].
Figure 3.
Envi-Met modeling process. (Version 5.6.1 Winter 23).
3.4. Microclimate Model Validation
The validation of microclimate model was conducted through a correlation of measured and simulated air temperature (Ta), relative humidity (RH), and wind speed (Ws). The validation was based on 13 hourly data points corresponding to the measurement period from 9 a.m. to 9 p.m. The results are presented in Figure 4. The measured air temperature exhibited a high correlation with the simulated air temperature using the ENVI-met microclimate model, with an R2 value of 0.91. This strong correlation indicates that the model is highly accurate in predicting air temperature variations caused by the presence of Ficus and Ash trees in the urban sequences studied. Similarly, the relative humidity showed strong congruence between the simulated and measured data points, with an R2 value of 0.90. This high level of accuracy suggests that the model reliably simulates the humidity changes influenced by the trees. However, the linear trend of wind speeds indicated a relatively lower correlation between measured and simulated values, with an R2 value of 0.6. This suggests that while the model performs well in simulating temperature and humidity, it is less accurate in predicting wind speed variations. This discrepancy might be due to the complex nature of wind patterns in urban environments, which can be influenced by numerous factors such as building configurations and other microscale obstructions that the model may not fully capture. In sum, the validation results demonstrate that the ENVI-met microclimate model has a high capacity and accuracy in providing reliable data for air temperature and relative humidity, essential for assessing the cooling effects of urban trees. While there is room for improvement in accurately simulating wind speed, the overall performance of the model is robust and provides a solid foundation for analyzing urban microclimate variations and thermal comfort levels.
Figure 4.
Correlation of simulated and measured microclimate parameters: (a) air temperature, (b) relative humidity, and (c) wind speed.
4. Results and Analysis
4.1. Urban Microclimate Variations
In order to examine the cooling effect of Ficus species (Ficus retusa and Ficus benjamina) and Ash trees (Fraxinus spp.) across downtown Annaba at a fine scale, output data derived from different simulations was used, enabling a comprehensive analysis of the cooling effect of different tree species on variations in urban microclimate.
4.1.1. Air Temperature
Our analysis began with air temperature (Ta). Figure 5 shows temporal trends and differences influenced by Ficus and Ash trees in the urban environment. During the study period, air temperatures showed a typical daily pattern with a rise from morning to a peak between 2 and 3 p.m., followed by a decrease toward the evening. Notably, Emir Abdelkader Street (sequence 3) recorded the maximum air temperature of 42.9 °C at 2 and 3 p.m. Conversely, the minimum air temperature (37.5 °C) was observed in Ibn Khaldoun Street (sequence 2) at 9 p.m. Sequences S1 (Cheikh Laarbi Tebessi Street) and S4 (adjacent to the municipal theatre) both lack vegetation in their current designs and exhibited elevated temperatures, with mean daily values around 38.5–38.7 °C and maximums exceeding 41.7 °C during peak afternoon hours. In S1, temperatures peaked at 42.7 °C at 3 p.m., while S4 reached 41.7 °C between 2 and 3 p.m. Simulations introducing urban trees notably reduced air temperatures in both sequences. Using Ficus species (Scenario 2), mean reductions ranged from 1.3 °C to 1.4 °C, with maximum decreases of up to 1.9 °C at 3–4 p.m. Ash trees (Scenario 3) achieved mean reductions of 0.9 °C, with maximum decreases around 1.7–1.8 °C during the same period. See Figure 5a,d. Sequence S2 (Ibn Khaldoun Street), also devoid of urban trees, showed a slightly lower mean temperature of 38.6 °C, peaking at 42.8 °C at 1 p.m., before dropping to 30.9 °C by 9 p.m. Simulated tree planting reduced temperatures moderately, with Ficus species yielding a mean reduction of 0.9 °C (max 1.7 °C at 1 and 4 p.m.) and Ash trees providing a smaller mean reduction of 0.4 °C (max 1.2 °C at 1 p.m.). See Figure 5b. Sequence S3 (Emir Abdelkader Street) experienced the highest temperatures overall, with a peak of 42.9 °C at 2–3 p.m. Tree simulations showed the greatest cooling effect here: Ficus species reduced temperatures by a mean of 2 °C, with a peak decrease of 3.6 °C at 9 a.m., while Ash trees reduced temperatures by a mean of 1.4 °C, with peak reductions exceeding 2 °C from 4 to 6 p.m. See Figure 5c.
Figure 5.
Comparison of air temperature for three simulated scenarios in four sequences: (a) sequence 1, (b) sequence 2, (c) sequence 3, and (d) sequence 4 (Leonardo–ENVI-met 5.6.1).
4.1.2. Relative Humidity
Relative humidity, the second microclimate parameter analyzed, indicates air moisture. Daily values for three scenarios were compared across four sequences from 9 a.m. to 9 p.m., as shown in Figure 6. The relative humidity pattern in the study area is the inverse of temperature, decreasing until early afternoon and rising in the evening. The lowest values occurred at 1 p.m. on Ibn Khaldoun Street (28.6%, S2) and Emir Abdelkader Street (28.9%, S3), while the highest, recorded in the early morning, did not exceed 58%. Relative humidity patterns varied slightly between sequences but generally showed morning peaks and early afternoon lows. The lowest daily averages occurred in S3, situated on Emir Abdelkader Street (35.8%), followed by S2, located in Ibn Khaldoun Street (38.3%), and S1, located in Cheikh Laarbi Tebessi Street (39.4%), while S4, corresponding to the Theatre Square, recorded the lowest maximum values overall (<40%). Introducing vegetation increased humidity in all cases, especially with Ficus species in Scenario 2, which outperformed Ash trees in Scenario 3 across sequences. In S1, Ficus species raised average humidity by 6.2% with a maximum of 8.4% at 2 p.m., while Ash trees added 3.5% with a maximum of 5% at 5 p.m. See Figure 6a. In S2, Ficus species produced the highest overall gains, up to 14% at 9 p.m. and over 10% during midday, while Ash trees achieved a 7.7% daily average increase with a maximum of 12% at 9 p.m. See Figure 6b. In S3, Ficus species increased daily averages by 5.6% with a maximum of 8.7%, and Ash trees by 3.6% with a maximum of 6.7% at 11 a.m. See Figure 6c. In S4, Ficus species boosted averages by 6.8% with a maximum of 14% at 9 a.m., compared to 4.3% for Ash trees. See Figure 6d.
Figure 6.
Comparison of relative humidity for three simulated scenarios in four sequences: (a) sequence 1, (b) sequence 2, (c) sequence 3, and (d) sequence 4 (Leonardo–ENVI-met 5.6.1).
4.1.3. Mean Radiant Temperature
As shown in Figure 7, the mean radiant temperature trend is consistent across all sequences, increasing from morning until 5 p.m. and then decreasing into the evening hours, with variations in the range for each sequence. In the current design without vegetation, Tmrt values were high across all sequences, ranging from 72.9 °C to 76.9 °C in the afternoon and dropping to 27.2–34.8 °C in the evening. Introducing urban trees reduced Tmrt notably, with Ficus species in Scenario 2 consistently outperforming Ash trees in Scenario 3. In S1 Figure 7a and S2 Figure 6b, Ficus species lowered Tmrt by 13.5 °C and 14.2 °C on average, with peak reductions of 30 °C and 25.4 °C at 5 p.m., respectively. Ash trees achieved smaller decreases, averaging 10.8 °C and 7.2 °C, with similar maximum drops of 27 °C and 25 °C at 5 p.m. S3, Figure 7c, showed the largest cooling effect, with Ficus species reducing Tmrt by 16.9 °C on average and up to 31 °C at 5 p.m., while Ash trees achieved 10.6 °C on average and a 28.4 °C maximum reduction. S4, Figure 7d, recorded the highest baseline Tmrt (76.9 °C at 3 p.m.). Here, Ficus species reduced Tmrt by 12.9 °C on average, peaking at 17.1 °C at 1 p.m., while Ash trees had a smaller effect (4.4 °C on average, 17.8 °C peak at 10 a.m.) and even increased Tmrt between 7 and 9 p.m. compared to the no-vegetation case.
Figure 7.
Comparison of mean radiant temperature for three simulated scenarios in four sequences: (a) sequence 1, (b) sequence 2, (c) sequence 3, and (d) sequence 4 (Leonardo–ENVI-met 5.6.1).
4.1.4. Wind Speed
Wind speeds were analyzed across three scenarios and four sequences from 9 a.m. to 9 p.m. The main results are shown in Figure 8. Overall, wind speeds were highest in Scenario 1 (no vegetation) and lowest in Scenario 2 (Ficus species), with Scenario 3 (Ash trees) showing intermediate values. In S1—Cheikh Laarbi Tebessi Street, Figure 8a, and S2—Ibn Khaldoun Street, Figure 8b, baseline wind speeds were relatively stable, 0.9 m/s in S1 and 1.1–1.2 m/s in S2. In S1, Ash trees reduced speeds by 0.1 m/s, while Ficus species produced a stronger variation, rising from 0.44 m/s at 9 a.m. to 0.72 m/s at 9 p.m. In S2, Ash trees lowered speeds by 0.2 m/s, while Ficus species showed a steady decline from 0.9 m/s at 9 a.m. to 0.7 m/s at 9 p.m. In S3—Emir Abdelkader Street, Figure 8c, all scenarios recorded 0.6–0.85 m/s with minimal variation. Ficus species increased speeds by 0.2 m/s, while Ash trees caused a 0.1 m/s drop. S4—Theatre Square, Figure 8d, had the highest baseline speeds, decreasing slightly from 1.4 m/s at 9 a.m. to 1.3 m/s in the evening. Ash trees reduced speeds by 0.4 m/s (0.9–1.0 m/s range), while Ficus species declined from 0.9 m/s to 0.7 m/s from morning to evening.
Figure 8.
Comparison of wind speed for three simulated scenarios in four sequences: (a) sequence 1, (b) sequence 2, (c) sequence 3, and (d) sequence 4 (Leonardo–ENVI-met 5.6.1).
4.2. Thermal Comfort Levels
Continuing our study, the PET index was used to assess the cooling effect of Ficus species (Ficus retusa and Ficus benjamina) and Ash trees (Fraxinus spp.) on thermal comfort across downtown Annaba at a fine scale, with the results presented in Figure 9. In the current design (Scenario 1, without urban trees), the PET index across all sequences indicated very high values, corresponding to a very hot thermal perception and extreme heat stress (Table 3). The PET generally rose from morning, peaking between 2 p.m. and 4 p.m., and then declined in the evening. S1—Cheikh Laarbi Tebessi Street recorded a mean daily PET of 47.5 °C, ranging from 39.6 °C (strong heat stress) at 9 p.m. to 55.5 °C (extreme heat stress) at 3 p.m. S2—Ibn Khaldoun Street had a similar pattern, with a mean of 45.4 °C, from 32.8 °C at 9 p.m. to 50.7 °C between 1 p.m. and 3 p.m. In both sequences, introducing Ficus species (Scenario 2) reduced PET notably, by 6.1 °C (S1) and 6.7 °C (S2) on average, with peak reductions of 6.3 °C at 1 p.m. (S1) and 10.8 °C at 5 p.m. (S2). Ash trees (Scenario 3) produced smaller average reductions of 4.5 °C (S1) and 5 °C (S2), with maxima of 6.7 °C at 1 p.m. (S1) and 7.8 °C at 4 p.m. (S2). See Figure 9a,b. S3—Emir Abdelkader Street showed the highest PET among street sequences, with a mean daily value of 50.2 °C, from 38.7 °C at 9 a.m. to 58.1 °C at 4 p.m. Ficus species lowered PET by 7.3 °C on average, with a peak reduction of 11.7 °C at 4 p.m., while Ash trees gave a 4.5 °C mean reduction. See Figure 8c. S4—Theatre Square displayed consistently high PET values in Scenario 1, averaging 50.6 °C (35.5 °C at 9 p.m. to 56 °C at 3 p.m.), with elevated levels from morning (53.6 °C at 9 a.m.) through late afternoon (54.5 °C daytime average). Scenario 2 (Ficus) reduced PET by 7.7 °C on average, exceeding 10 °C at 2–3 p.m., while Scenario 3 (Ash) yielded a 4.5 °C average reduction, with maxima during early morning hours. See Figure 9d.
Figure 9.
Comparison of PET index for three simulated scenarios in four sequences: (a) sequence 1, (b) sequence 2, (c) sequence 3, and (d) sequence 4 (Leonardo–ENVI-met 5.6.1).
5. Discussion
5.1. Cooling Effect of Different Tree Species
5.1.1. Effect of Ficus Species
In Cheikh Laarbi Tebessi Street, the broad canopy of Ficus retusa intercepted sunlight and, through shading and evapotranspiration, reduced air and surface temperatures while increasing relative humidity, thereby enhancing evaporative cooling and lowering heat stress [39,40]. Our findings align with these studies, confirming that dense Ficus canopies effectively moderate microclimates by combining shading and evapotranspiration effects. The reduction in solar radiation absorption by asphalt and concrete also decreased mean radiant temperature, a critical factor for thermal comfort [41,42]. Similarly, our results demonstrate a notable Tmrt MRT reduction linked to surface material shading, consistent with their observations. Similar cooling benefits were observed in Ibn Khaldoun Street, where 16 Ficus species, eight along the median and four on each sidewalk, provided extensive shading. This substantially reduced Tmrt and improved thermal comfort. Although trees slightly decreased localized wind speeds, the shading and cooling effects far outweighed this limitation [43,44]. This concurs with our results, where minor wind speed reduction did not diminish the overall cooling and comfort improvements from canopy shading. The effectiveness of Ficus species was further confirmed in Emir Abdelkader Street, where medium Ficus retusa trees in the median and young Ficus benjamina on sidewalks notably lowered air and surface temperatures, increased relative humidity by 5.6%, reduced MRT by 16.9 °C, and lowered PET by 7.3 °C. These results reinforce the role of canopy density and foliage coverage in maximizing cooling performance. A similar pattern emerged in Theatre Square, where Ficus retusa trees arranged in a “II” pathway facilitated pedestrian movement while optimizing shade and airflow. Variations in pedestrian mean radiant temperature are strongly influenced by the spacing and size of street trees, which affect shading patterns and airflow [45]. Our findings on the cooling effects of Ficus and Fraxinus spp. align with this, as canopy density and tree arrangement played key roles in reducing Tmrt and decreased PET by 7.7 °C, again demonstrating that the combined effects of shading, transpiration, and humidity moderation can markedly enhance urban thermal comfort without substantially compromising wind flow.
5.1.2. Cooling Effect of Fraxinus spp.
In Cheikh Laarbi Tebessi Street, old Fraxinus spp. were simulated with the same tree arrangement as the Ficus scenario. The rounded canopy of Fraxinus spp. provided shading, although less effectively than the broad canopy of Ficus retusa. The process of evapotranspiration in Fraxinus spp. also contributed to cooling the air, albeit to a slightly lesser extent. The increase in relative humidity and reductions in mean radiant temperature were more modest compared to Ficus species. However, the Fraxinus trees still provided notable cooling benefits, highlighting their role in urban microclimate regulation. In Ibn Khaldoun Street, the simulation of Fraxinus spp. along the median aisle and sidewalks resulted in a mean temperature reduction of 0.4 °C. The increase in relative humidity was less pronounced compared to Ficus species but still contributed to a more pleasant microclimate, reflecting its modest evaporative effect [39,46]. The shading provided by the rounded canopies of Fraxinus trees reduced temperatures, although to a lesser extent than Ficus species. Reductions in mean radiant temperature and changes in wind speed patterns were also less substantial but still contributed to improved thermal comfort. The presence of Fraxinus trees led to minor variations in wind speed, which did not notably impact overall thermal comfort. In Emir Abdelkader Street, old Fraxinus trees were simulated along the median aisle and young Fraxinus trees on the sidewalks, maintaining the same tree arrangement as the Ficus scenario. This setup resulted in a mean temperature reduction of 1.4 °C. The increase in relative humidity with the introduction of Fraxinus trees was modest but still contributed to a more comfortable microclimate. The PET index showed a mean reduction of 4.5 °C, indicating notable improvements in thermal comfort. The shading and evaporative cooling effects of Fraxinus trees played a crucial role in these reductions, which largely agreed with previous studies [47]. In the Theatre Square, old Fraxinus trees were arranged similarly to the Ficus scenario. The shading provided by Fraxinus trees resulted in a modest reduction in mean radiant temperature, although there was an increase in Tmrt during the evening hours compared to the current design. This could be attributed to changes in airflow patterns caused by the presence of trees. The PET index showed a mean reduction of 4.5 °C, reflecting the enhancement of thermal comfort within the theatre square due to the cooling effects of shading and evapotranspiration. Wind speeds exhibited slight variations, with a minor increase observed in this scenario.
It is important to note that, although the studied tree species contributed to an increase in relative humidity due to evapotranspiration, this effect should be considered in relation to Annaba’s coastal climate, which is already characterized by relatively high humidity levels. While increased humidity can enhance cooling through evaporative processes, excessive humidity may reduce thermal comfort by limiting evaporative cooling from the human body.
5.2. Green Canopy for Cool City
Recognizing the pivotal role of Ficus species in microclimate regulation and thermal comfort enhancement, the investigation focused on the cooling effects during the hottest hours of the day, specifically from noon to 3 p.m. These hours, consistently identified across all sequences, represent critical periods for assessing the efficacy of diverse tree species in mitigating heat stress. The cooling differences presented in Figure 10 were calculated as the mean reduction in air temperature and PET index, and the mean increase in relative humidity between the reference scenario and the tree-planted scenarios.
Figure 10.
Mean reductions in air temperature, PET index, and mean increase in relative humidity of Ficus and Fraxinus spp. for the period from 12 p.m. to 3 p.m. (a) Streets and (b) square.
In view of the different spatial configurations of the studied sequences, streets and a square, the findings will be discussed separately. The streets share common features such as narrow geometry and medium-sized buildings, while the square has a specific design characterized by openness. Additionally, the concurrent increase in relative humidity is explored, a crucial factor in understanding the overall cooling dynamics. The comparison of the cooling effect of different tree species during hot hours is depicted in Figure 10. Both species, Ficus and Fraxinus, in the streets demonstrated nearly the same reduction in air temperature during the hottest hours, estimated at 1.3 °C. However, a notable enhancement in thermal comfort levels was observed with the Ficus species, which showed a reduction of 7.4 °C in the PET index. This pronounced effect is attributed to the dense foliage of Ficus species and their greater capacity to generate water vapor into the atmosphere, leading to a notable increase in relative humidity. See Figure 10a. These results align with previous studies that emphasize the critical role of dense tree canopies and high transpiration rates in urban heat mitigation [48,49]. For the square, characterized by its greater openness, Ficus species demonstrated a more pronounced reduction in air temperature during the hottest hours, estimated at 1.4 °C. This cooling effect was accompanied by a notable increase in relative humidity of 4.4%, attributed to the dense leaf mass of Ficus species compared to the less thick canopy of Fraxinus trees. The substantial foliage of Ficus enhances evapotranspiration, which contributes to both the temperature reduction and the increase in relative humidity. Consequently, this leads to a marked improvement in thermal comfort levels, evidenced by a reduction of 9.9 °C in the PET index during the peak heat hours. See Figure 10a. These findings highlight the superior cooling performance of Ficus species in open urban environments, attributable to their dense foliage and high transpiration rates. Through the process of evapotranspiration, the thick leaf mass of Ficus species releases greater amounts of water vapor, cooling the surrounding air more effectively than species with lighter canopies. This mechanism not only lowers air temperature but also increases relative humidity, reducing the perceived temperature and improving thermal comfort. Combined with the shading effect provided by their dense canopy, these factors create a more comfortable and stable microclimate, effectively mitigating heat stress in urban open spaces. Such findings are supported by studies demonstrating the importance of canopy density and leaf area index in enhancing urban thermal comfort, especially in open spaces [50,51].
To provide a more accurate explanation, the mean heat exchange by radiation of Ficus retusa and Fraxinus spp. species for the period is up for discussion from 12 p.m. to 3 p.m. See Table 5. Heat exchange by radiation primarily refers to the exchange of short-wave radiation. Short-wave radiation consists of the electromagnetic radiation emitted by the sun, including visible light, ultraviolet, and near-infrared wavelengths. During the critical midday hours, the interaction between urban greenery and short-wave radiation notably influences the microclimate. This interaction has been highlighted in earlier works exploring the role of urban vegetation in altering radiation balance [52,53]. Ficus retusa, with its dense leaf canopy, effectively intercepts and absorbs more short-wave radiation compared to Fraxinus spp. In the streets, the Ficus species exhibit a high amount of direct short-wave radiation (SWR) at 614.3 W/m2, with the proportion of diffuse SWR relatively low at 8.4%, while the reflected SWR is 236.6 W/m2, accounting for 25.3% of the direct SWR, suggesting that a notable portion of the incoming radiation is being reflected by leaves and other surfaces. Consequently, a substantial percentage of long-wave radiation is retained under the canopy, contributing to a cooler atmosphere. For the Fraxinus spp., the direct SWR is lower at 404.4 W/m2. The diffuse SWR is similar to that of the Ficus species, but the percentage (11.5%) is slightly lower. The reflected SWR is notably higher at 102.9 W/m2, which is 25.4% of the direct SWR. This indicates that Fraxinus trees reflect less short-wave radiation compared to Ficus species, contributing to higher ground and air temperatures. In the square, characterized by its greater openness, the Ficus species receive a very high direct SWR of 1004.4 W/m2. The diffuse SWR is 83.9 W/m2, which constitutes 5.9% of the total SWR, indicating more scattering of radiation due to the open space. The reflected SWR is 254.2 W/m2, making up 38.5% of the total SWR. This reflects the ability of Ficus species to intercept and scatter a substantial amount of radiation, enhancing cooling through increased evapotranspiration. For Fraxinus spp. in the square, the direct SWR is 527.8 W/m2, which is notably lower than that for Ficus. The diffuse SWR is 61.1 W/m2 (9%), and the reflected SWR is 97.5 W/m2, accounting for 25.4% of the total SWR. This high reflection percentage indicates less absorption and scattering by the leaves, which results in a lower cooling effect compared to Ficus species.
Table 5.
Mean heat exchange by radiation of Ficus retusa and Fraxinus spp. species for the period from 12 to 3 p.m.
Overall, the results show that Ficus species are more effective in reducing heat through higher absorption and scattering of short-wave radiation, particularly in open areas like the square. This is evidenced by the higher reflected SWR percentages and the lower diffuse SWR percentages for Ficus species compared to Fraxinus spp. The dense leaf mass of Ficus species contributes to higher rates of evapotranspiration, which not only lowers air temperatures but also increases relative humidity, thereby enhancing thermal comfort. In contrast, Fraxinus spp. reflects a larger portion of the incoming radiation, which results in less effective cooling. Such results were found in Guelma city, locating at 60 km of Annaba city, where the authors demonstrated the effectiveness of Ficus species in cooling down the summer temperatures compared to other trees species [54].
5.3. Implications for Urban Planning and Tree Management Policies
In Annaba, where tree selection depends on existing flora, understanding cooling effect studies is vital for shaping microclimates and improving thermal comfort through effective urban planning.
- The selection of tree species while considering Annaba’s climatic shifts and the city’s layout characterized by narrow streets and open squares, such as choosing tree species with high cooling potential, such as Ficus retusa and Ficus benjamina, can notably alleviate heat stress.
- In Annaba’s narrow streets, where buildings often obstruct airflow and intensify heat buildup, strategic placement of Ficus species can provide shade and cooling benefits without obstructing pedestrian and vehicular movement.
- Urban planners in Annaba should prioritize developing green corridors and pocket parks featuring Ficus species to maximize cooling benefits and improve residents’ well-being.
- Given Annaba’s intense summer heat, urban planners should adopt tree-centric strategies, prioritizing the planting and maintenance of trees, particularly in dense neighborhoods and commercial districts, to create cooler environments and reduce heat-related health risks.
- Incorporating climate resilience and adaptation strategies into Annaba’s long-term urban planning efforts is imperative.
5.4. Limitations and Suggestions for Future Research
This study aimed at investigating the cooling effects exerted by different tree species on the urban microclimate and thermal comfort levels within downtown Annaba during the summer season; several limitations that warrant acknowledgment were encountered and suggest avenues for future research. Our study advances current knowledge by providing a fine-scale analysis of the microclimatic impacts of specific tree species in an urban Mediterranean context, highlighting the superior cooling efficacy of Ficus species over Fraxinus spp. Additionally, it offers practical urban planning recommendations for cities with similar climates. One notable limitation pertains to the out-of-category values obtained for the PET index, which may impede the accurate assessment of thermal comfort levels. Addressing this limitation could involve exploring alternative comfort indices better suited to the Mediterranean climate of the region. Future studies may consider developing a new categorization of thermal indices tailored specifically to the climatic shifts in the Mediterranean region, thereby enhancing the precision of thermal comfort assessments. Furthermore, our study focused on two tree species; Ficus retusa and Fraxinus spp., which are prevalent in Annaba city. While these species are commonly encountered in the urban landscape, future research could expand the scope by investigating the cooling effects of other tree species native to the region. By exploring a broader range of species, researchers can gain a more comprehensive understanding of their respective contributions to urban microclimate regulation and thermal comfort enhancement. Additionally, our study examined sequences at a fine scale, or the microscale, to account for the intricacies of urban environments, such as the layout of streets, sidewalks, and commercial activity areas. This choice was guided by our vision to plant trees with meticulous attention to detail, considering factors such as the size of streets and sidewalks, as well as the location of doors on the ground floor of buildings. While this approach offers valuable insights into localized cooling effects, future studies may explore other spatial scales, such as the mesoscale or macroscale, to capture the broader impact of tree planting initiatives across downtown Annaba. It should be noted that the simulated scenarios incorporate not only differences in tree species but also variations in tree morphological characteristics and spatial configurations. Therefore, the observed differences in cooling performance reflect the combined effect of species traits, crown architecture, tree dimensions, and planting arrangement rather than species identity alone. Future studies should isolate the effect of species by controlling morphological and spatial parameters. Moreover, the simulations assumed stable tree morphological and physiological characteristics. Future climate conditions, such as increased temperatures and drought stress, may alter crown density, leaf area, and transpiration, affecting tree cooling performance. Future studies should consider these dynamic responses under changing climate scenarios. By utilizing models capable of simulating climate processes at different scales, researchers can assess the scalability and efficacy of urban greening strategies in mitigating heat stress and enhancing urban comfort. Moreover, the straightforward geometric layout of streets and plots in downtown Annaba presents opportunities for replicating the square design in other urban areas. Future research could replicate our methodology in similar settings, such as empty plots within downtown areas, to evaluate the transferability of our findings and assess the effectiveness of tree planting interventions in diverse contexts.
6. Conclusions
Our study investigated the cooling effects of different tree species on the urban microclimate and thermal comfort in downtown Annaba during summer. Field measurements and ENVI-met simulations assessed the impact of Ficus and Fraxinus spp. on air temperature, relative humidity, mean radiant temperature, and the PET index. Results showed that urban trees, particularly Ficus species, provided superior cooling, reducing air temperature by up to 2 °C and PET by up to 7.7 °C, and increasing relative humidity by up to 6.8%. These effects were strongest in open areas like Theatre Square, where dense foliage and high transpiration rates improved thermal comfort. Fraxinus spp. also had positive effects but to a lesser degree, with lower temperature and PET reductions due to sparser foliage. For urban planning, selecting and placing tree species with high cooling potential, such as Ficus retusa and Ficus benjamina, can notably reduce heat stress. Street-level measurements confirmed these benefits, with temperature reductions of up to 2 °C and PET drops of up to 7.3 °C in various downtown locations. Expanding green corridors and pocket parks, especially in commercial areas where buildings obstruct airflow, can further enhance air quality and well-being. Future research should refine thermal comfort indices and explore other species in different urban settings.
Author Contributions
Conceptualization, B.S., O.A.O. and E.K.K.; methodology, B.S., M.A.A. (Mohanad A. Alfelali) and H.A.N.; software, M.A.A. (Mohanad A. Alfelali) and M.A.A. (Mohammad A. Almahdi); validation, O.A.O., E.K.K. and A.A.A.; formal analysis, E.K.K., H.A.N. and W.S.Q.; investigation, B.S., O.A.O. and E.K.K.; resources, B.S., O.A.O., A.A.A. and W.S.Q.; data curation, B.S., M.A.A. (Mohammad A. Almahdi), H.A.N. and A.A.A.; writing—original draft preparation, B.S., O.A.O. and W.S.Q.; writing—review and editing, M.A.A. (Mohanad A. Alfelali), H.A.N., W.S.Q. and M.A.A. (Mohammad A. Almahdi); visualization, B.S. and M.A.A. (Mohammad A. Almahdi); supervision, W.S.Q. and A.A.A.; project administration, B.S. and M.A.A. (Mohanad A. Alfelali). All authors have read and agreed to the published version of the manuscript.
Funding
This research received no external funding.
Data Availability Statement
All data, models, and code generated or used during the study appear in the submitted article.
Acknowledgments
We acknowledge the use of Large Language Model tools exclusively for language editing, grammatical correction, and improvement of manuscript clarity.
Conflicts of Interest
The authors declare no conflicts of interest.
References
- Ponraj, M.; Lee, Y.Y.; Din, M.F.M.; Noor, Z.Z.; Iwao, K.; Chelliapan, S. Overview of urban heat island (uhi) phenomenon towards human thermal comfort. Environ. Eng. Manag. J. 2017, 16, 2097–2111. [Google Scholar] [CrossRef] [Scilit]
- Yin, Z.; Liu, Z.; Liu, X.; Zheng, W.; Yin, L. Urban heat islands and their effects on thermal comfort in the US: New York and New Jersey. Ecol. Indic. 2022, 154, 110765. [Google Scholar] [CrossRef] [Scilit]
- Nuruzzaman, M. Urban Heat Island: Causes, Effects and Mitigation Measures—A Review. Int. J. Environ. Monit. Anal. 2015, 3, 67. [Google Scholar] [CrossRef] [Scilit]
- Yang, L.; Qian, F.; Song, D.-X.; Zheng, K.-J. Research on Urban Heat-Island Effect. Procedia Eng. 2016, 169, 11–18. [Google Scholar] [CrossRef] [Scilit]
- Badin, G.; Ahmad, N.; Huang, Y.; Mahmood, Y. Evaluation of Pigment-Modified Clear Binders and Asphalts: An Approach towards Sustainable, Heat Harvesting, and Non-Black Pavements. Infrastructures 2024, 9, 88. [Google Scholar] [CrossRef] [Scilit]
- Sen, S.; Roesler, J.; Ruddell, B.; Middel, A. Cool Pavement Strategies for Urban Heat Island Mitigation in Suburban Phoenix, Arizona. Sustainability 2019, 11, 4452. [Google Scholar] [CrossRef] [Scilit]
- Yang, X.; Zhao, L.; Bruse, M.; Meng, Q. Evaluation of a microclimate model for predicting the thermal behavior of different ground surfaces. Build. Environ. 2013, 60, 93–104. [Google Scholar] [CrossRef] [Scilit]
- Wemegah, C.S.; Yamba, E.I.; Aryee, J.N.; Sam, F.; Amekudzi, L.K. Assessment of urban heat island warming in the greater accra region. Sci. Afr. 2020, 8, e0042. [Google Scholar] [CrossRef] [Scilit]
- Técher, M.; Haddou, H.A.; Aguejdad, R. Urban Heat Island’s Vulnerability Assessment by Integrating Urban Planning Policies: A Case Study of Montpellier Méditerranée Metropolitan Area, France. Sustainability 2023, 15, 1820. [Google Scholar] [CrossRef] [Scilit]
- Scafetta, N. Impacts and risks of “realistic” global warming projections for the 21st century. Geosci. Front. 2024, 15, 101774. [Google Scholar] [CrossRef] [Scilit]
- Yuan, J.; Lin, Q.; Chen, S.; Zhao, H.; Xie, X.; Cai, Z.; Zhang, J.; Cheng, T.; Hua, M.; Zhang, R. Influence of global warming and urbanization on regional climate of Megacity: A case study of Chengdu, China. Urban Clim. 2022, 44, 101227. [Google Scholar] [CrossRef] [Scilit]
- Founda, D.; Katavoutas, G.; Pierros, F.; Mihalopoulos, N. The Extreme Heat Wave of Summer 2021 in Athens (Greece): Cumulative Heat and Exposure to Heat Stress. Sustainability 2022, 14, 7766. [Google Scholar] [CrossRef] [Scilit]
- Malikah, S.; Avila, S.; Garcia, G.; Lakhankar, T. Historical Climate Trends and Extreme Weather Events in the Tri-State Area: A Detailed Analysis of Urban and Suburban Differences. Climate 2024, 12, 32. [Google Scholar] [CrossRef] [Scilit]
- Colangelo, M.; Camarero, J.J.; Gazol, A.; Piovesan, G.; Borghetti, M.; Baliva, M.; Gentilesca, T.; Rita, A.; Schettino, A.; Ripullone, F. Mediterranean old-growth forests exhibit resistance to climate warming. Sci. Total. Environ. 2021, 801, 149684. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Huang, Q.; Meng, X.; Yang, X.; Jin, L.; Liu, X.; Hu, W. The Ecological City: Considering Outdoor Thermal Environment. Energy Procedia 2016, 104, 177–182. [Google Scholar] [CrossRef] [Scilit]
- Shashua-Bar, L.; Pearlmutter, D.; Erell, E. The influence of trees and grass on outdoor thermal comfort in a hot-arid environment. Int. J. Clim. 2011, 31, 1498–1506. [Google Scholar] [CrossRef] [Scilit]
- Aminipouri, M.; Knudby, A.J.; Krayenhoff, E.S.; Zickfeld, K.; Middel, A. Modelling the impact of increased street tree cover on mean radiant temperature across Vancouver’s local climate zones. Urban For. Urban Green. 2019, 39, 9–17. [Google Scholar] [CrossRef] [Scilit]
- Abdel-Aziz, D.M.; Al Shboul, A.; Al-Kurdi, N.Y. Effects of Tree Shading on Building’s Energy Consumption-The Case of Residential Buildings in a Mediterranean Climate. Am. J. Environ. Eng. 2015, 5, 131–140. [Google Scholar] [CrossRef]
- Zhang, M.; Wang, J.; Zhang, F. The Influence of Spatial Heterogeneity of Urban Green Space on Surface Temperature. Forests 2024, 15, 878. [Google Scholar] [CrossRef] [Scilit]
- de Abreu-Harbich, L.V.; Labaki, L.C.; Matzarakis, A. Effect of tree planting design and tree species on human thermal comfort in the tropics. Landsc. Urban Plan. 2015, 138, 99–109. [Google Scholar] [CrossRef] [Scilit]
- Zhang, Y.; Rao, F.; Xue, J.; Lai, D. Dependence of urban park visits on thermal environment and air quality. Urban For. Urban Green. 2022, 79, 127813. [Google Scholar] [CrossRef] [Scilit]
- Yuan, C.; Ng, E.; Norford, L.K. Improving air quality in high-density cities by understanding the relationship between air pollutant dispersion and urban morphologies. Build. Environ. 2014, 71, 245–258. [Google Scholar] [CrossRef] [Scilit] [PubMed]
- Bienu, S.A.; Lubalega, T.K.; Khasa, D.P.; Kaviriri, D.K.; Yang, L.; Yuhua, L.; Eyul’ANki, D.M.; Tango, E.K.; Katula, H.B. Floristic diversity and structural parameters on the forest tree population in the Luki biosphere reserve, Democratic Republic of Congo. Glob. Ecol. Conserv. 2023, 44, e02489. [Google Scholar] [CrossRef] [Scilit]
- Mohammed, E.M.; Hassan, T.T.; Idris, E.A.; Abdel-Magid, T.D. Tree population structure, diversity, regeneration status, and potential disturbances in Abu Gadaf natural reserved forest, Sudan. Environ. Chall. 2021, 5, 100366. [Google Scholar] [CrossRef] [Scilit]
- Niang, F.; Marchand, P.; Sambou, B.; Fenton, N. Exploring the effects of forest management on tree diversity, community composition, population structure and carbon stocks in sudanian domain of Senegal, West Africa. For. Ecol. Manag. 2024, 559, 121821. [Google Scholar] [CrossRef] [Scilit]
- Sayad, B.; Osra, O.A.; Binyaseen, A.M.; Qattan, W.S. Analyzing Urban Climatic Shifts in Annaba City: Decadal Trends, Seasonal Variability and Extreme Weather Events. Atmosphere 2024, 15, 529. [Google Scholar] [CrossRef] [Scilit]
- Sayad, B.; Helmi, M.R.; Osra, O.A.; Abed, A.M.; Alhubashi, H.H. Microscale Investigation of Urban Heat Island (UHI) in Annaba City: Unveiling Factors and Mitigation Strategies. Sustainability 2024, 16, 747. [Google Scholar] [CrossRef] [Scilit]
- Boussaidi, K.; Djaghrouri, D.; Benabbas, M.; Altan, H. Assessment of Outdoor Thermal Comfort in Urban Public Space, during the Hottest Period in Annaba City, Algeria. Sustainability 2023, 15, 11763. [Google Scholar] [CrossRef] [Scilit]
- Shashua-Bar, L.; Rahman, M.A.; Moser-Reischl, A.; Peeters, A.; Franceschi, E.; Pretzsch, H.; Rötzer, T.; Pauleit, S.; Winters, G.; Groner, E.; et al. Do urban tree hydraulics limit their transpirational cooling? A comparison between temperate and hot arid climates. Urban Clim. 2023, 49, 101554. [Google Scholar] [CrossRef] [Scilit]
- Rahman, M.A.; Arndt, S.; Bravo, F.; Cheung, P.K.; van Doorn, N.; Franceschi, E.; del Río, M.; Livesley, S.J.; Moser-Reischl, A.; Pattnaik, N.; et al. More than a canopy cover metric: Influence of canopy quality, water-use strategies and site climate on urban forest cooling potential. Landsc. Urban Plan. 2024, 248, 105089. [Google Scholar] [CrossRef] [Scilit]
- Annaba—Wikipédia. Available online: https://fr.wikipedia.org/wiki/Annaba (accessed on 25 May 2024).
- Les 20 Plantes les Plus Communes en Annaba. Available online: https://www.picturethisai.com/fr/region/Algeria-Annaba-Annaba.html (accessed on 25 May 2024).
- Mohcene, A. Ecologie des Zones Humides de la wilaya d ’ Annaba Nord—Est Algérien. Ph.D. Thesis, Universite Badji Mokhtar, Annaba, Algeria, 2022. [Google Scholar]
- Mayer, H.; Höppe, P. Thermal Comfort of Man in Different Urban Environments. Theor. Appl. Climatol. 1987, 38, 43–49. [Google Scholar]
- Zare, S.; Hasheminejad, N.; Shirvan, H.E.; Hemmatjo, R.; Sarebanzadeh, K.; Ahmadi, S. Comparing Universal Thermal Climate Index (UTCI) with selected thermal indices/environmental parameters during 12 months of the year. Weather. Clim. Extrem. 2018, 19, 49–57. [Google Scholar] [CrossRef] [Scilit]
- Sharmin, T.; Steemers, K.; Humphreys, M. Outdoor thermal comfort and summer PET range: A field study in tropical city Dhaka. Energy Build. 2019, 198, 149–159. [Google Scholar] [CrossRef] [Scilit]
- Albdour, M.S.; Baranyai, B. An overview of microclimate tools for predicting the thermal comfort, meteorological parameters and design strategies in outdoor spaces. Pollack Period. 2019, 14, 109–118. [Google Scholar] [CrossRef] [Scilit]
- O’Malley, C.; Piroozfarb, P.A.E.; Farr, E.R.P.; Gates, J. An Investigation into Minimizing Urban Heat Island (UHI) Effects: A UK Perspective. Energy Procedia 2014, 62, 72–80. [Google Scholar] [CrossRef] [Scilit]
- Tan, P.Y.; Wong, N.H.; Tan, C.L.; Jusuf, S.K.; Chang, M.F.; Chiam, Z.Q. A method to partition the relative effects of evaporative cooling and shading on air temperature within vegetation canopy. J. Urban Ecol. 2018, 4, juy012. [Google Scholar] [CrossRef] [Scilit]
- Huang, Z.; Wu, C.; Teng, M.; Lin, Y. Impacts of Tree Canopy Cover on Microclimate and Human Thermal Comfort in a Shallow Street Canyon in Wuhan, China. Atmosphere 2020, 11, 588. [Google Scholar] [CrossRef] [Scilit]
- Gao, N.; Zhang, H.; Wang, P.; Ning, L.; Wong, N.H.; Yu, H.; Ke, Z. Research on Microclimate-Suitable Spatial Patterns of Waterfront Settlements in Summer: A Case Study of the Nan Lake Area in Wuhan, China. Sustainability 2023, 15, 15687. [Google Scholar] [CrossRef] [Scilit]
- Hwang, R.-L.; Lin, T.-P.; Matzarakis, A. Seasonal effects of urban street shading on long-term outdoor thermal comfort. Build. Environ. 2011, 46, 863–870. [Google Scholar] [CrossRef] [Scilit]
- Abaas, Z.R. Impact of development on Baghdad’s urban microclimate and human thermal comfort. Alex. Eng. J. 2020, 59, 275–290. [Google Scholar] [CrossRef] [Scilit]
- Adamovský, D.; Kny, M. Influence of Airflow on Thermal Comfort in an Energy-Saving House. IOP Conf. Ser. Earth Environ. Sci. 2019, 290, 232–240. [Google Scholar] [CrossRef] [Scilit]
- Park, C.Y.; Lee, D.K.; Krayenhoff, E.S.; Heo, H.K.; Hyun, J.H.; Oh, K.; Park, T.Y. Variations in pedestrian mean radiant temperature based on the spacing and size of street trees. Sustain. Cities Soc. 2019, 48, 101521. [Google Scholar] [CrossRef] [Scilit]
- Tahir, H.M.M.; Yousif, T.A. Modeling the Effect of Urban Trees on Relative Humidity in Khartoum State. J. For. Prod. Ind. 2013, 2, 20–24. [Google Scholar]
- Cheung, P.K.; Jim, C. Improved assessment of outdoor thermal comfort: 1-hour acceptable temperature range. Build. Environ. 2019, 151, 303–317. [Google Scholar] [CrossRef] [Scilit]
- Bowler, D.E.; Buyung-Ali, L.; Knight, T.M.; Pullin, A.S. Urban greening to cool towns and cities: A systematic review of the empirical evidence. Landsc. Urban Plan. 2010, 97, 147–155. [Google Scholar] [CrossRef] [Scilit]
- Chen, H.; Liu, R.; Zhang, Y. The Impact of Vegetation Canopy on the Outdoor Thermal Environment in Cold Winter and Spring. Sustainability 2023, 15, 12818. [Google Scholar] [CrossRef] [Scilit]
- Teshnehdel, S.; Akbari, H.; Di Giuseppe, E.; Brown, R.D. Effect of tree cover and tree species on microclimate and pedestrian comfort in a residential district in Iran. Build. Environ. 2020, 178, 106899. [Google Scholar] [CrossRef] [Scilit]
- Yu, Z.; Guo, X.; Jørgensen, G.; Vejre, H. How can urban green spaces be planned for climate adaptation in subtropical cities? Ecol. Indic. 2017, 82, 152–162. [Google Scholar] [CrossRef] [Scilit]
- Laschewski, G.; Jendritzky, G. Effects of the thermal environment on human health: An investigation of 30 years of daily mortality data from SW Germany. Clim. Res. 2002, 21, 91–103. [Google Scholar] [CrossRef] [Scilit]
- Ali-Toudert, F.; Djenane, M.; Bensalem, R.; Mayer, H. Outdoor thermal comfort in the old desert city of Beni-Isguen, Algeria. Clim. Res. 2005, 28, 243–256. [Google Scholar] [CrossRef] [Scilit]
- Sayad, B.; Alkama, D.; Ibrahim, H.S.; Hegazy, I.R.; Imam, A.A.; Abed, A.M.; Alhubashi, H.H. Simulation-based educational approach toward improving thermal outdoor comfort for pedestrians in semi-arid climate. Int. J. Low-Carbon Technol. 2023, 18, 69–81. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content. |
© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.


























