Skip to Content
You are currently on the new version of our website. Access the old version .
Current OncologyCurrent Oncology
  • Article
  • Open Access

4 November 2026

14 Pages

Automated Trimodal Deep Learning Fusion of MRI, CT, and Endoscopy for Preoperative Differentiation of Sinonasal Inverted Papilloma and Malignant Transformation

,
,
,
,
,
,
,
and
1
Department of Otolaryngology, Research Units of New Technologies of Endoscopic Surgery in Skull Base Tumor (2018RU003), Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100730, China
2
ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai 200031, China
*
Authors to whom correspondence should be addressed.
†
These authors contributed equally to this work.

Simple Summary

Sinonasal inverted papilloma is a benign tumor of the nasal cavity and sinuses that can contain areas of squamous cell carcinoma. Identifying these areas before surgery is challenging because biopsy samples only part of the tumor. We investigated whether combining magnetic resonance imaging, computed tomography, and nasal endoscopy through a deep learning approach could help distinguish benign papilloma from papilloma associated with carcinoma. Separate unimodal models for each examination were developed using the available images from a cohort of 743 patients. The combined model showed promising diagnostic performance when evaluated using cross-validation in 106 patients with all three examinations. By integrating complementary information from routinely available examinations, this approach could support the preoperative recognition of carcinoma associated with inverted papilloma and inform further diagnostic assessment and surgical planning.

Abstract

Purpose: To develop and validate an automated trimodal deep learning fusion framework integrating magnetic resonance imaging (MRI), computed tomography (CT), and nasal endoscopy for preoperative differentiation between sinonasal inverted papilloma (SIP) and SIP-transformed squamous cell carcinoma (SIP-SCC). Materials and Methods: This retrospective study included 849 patients with pathological diagnoses of SIP (n = 614) or SIP-SCC (n = 235) between October 2014 and August 2025. Three unimodal ResNet-based deep learning models were trained and validated using data from 743 patients with only one or two modalities. The trained networks then generated MRI, CT, and endoscopy probability scores for each of 106 separate patients with complete trimodal data. These scores were combined using logistic regression, with fusion performance assessed by five-fold cross-validation in the 106-patient cohort. In the reader study, its performance was compared with six physicians (three junior, three senior). Results: The trimodal fusion model achieved an out-of-fold AUC of 0.910. Its AUC was higher than that of CT (0.634; unadjusted p < 0.001; Holm-adjusted p < 0.001) and endoscopy (0.813; unadjusted p = 0.023; Holm-adjusted p = 0.045), but the difference from MRI (0.859; unadjusted and adjusted p = 0.142) was not statistically significant. At the fixed threshold of 0.5, the fusion model achieved an accuracy of 83.0%. Accuracy differed significantly between the fusion model and the junior-reader group majority vote (64.2%; unadjusted p = 0.004; adjusted p = 0.022), but not the senior-reader group majority vote (81.1%; unadjusted p = 0.860; adjusted p = 1.000). Conclusions: By integrating MRI, CT, and endoscopy images, the trimodal fusion model achieved the highest AUC among the evaluated models for differentiating SIP from SIP-SCC, suggesting its potential value as a clinical decision support tool.

1. Introduction

Sinonasal inverted papilloma (SIP) is a benign sinonasal epithelial tumor characterized by local aggressiveness, high recurrence rate, and potential for malignant transformation [1]. SIP progresses to inverted papilloma-transformed squamous cell carcinoma (SIP-SCC) in 5–10% of cases [2,3]. Malignant transformation may require more extensive surgery and adjuvant therapy, making preoperative differentiation important [4].
Preoperative differentiation between SIP and SIP-SCC remains challenging. Endoscopic biopsy may miss a focal carcinomatous component within an otherwise benign papilloma [5,6,7]. Imaging complements tissue sampling by identifying suspicious regions that may warrant targeted biopsy and by delineating disease extent. Magnetic resonance imaging (MRI) and computed tomography (CT) provide complementary information. On T2-weighted and contrast-enhanced T1-weighted MRI, SIP often exhibits a convoluted cerebriform pattern consisting of alternating bands of high and low signal intensity [8]. Focal loss of this pattern and restricted diffusion may indicate an associated carcinoma [9]. CT depicts bone remodeling, erosion, and destruction [10], while focal hyperostosis can help identify the tumor attachment site for surgical planning [11]. However, overlapping appearances limit definitive discrimination by individual imaging findings [8,12].
To address these challenges, researchers have explored radiomics analysis [2,12,13,14,15] and deep learning (DL) models based on endoscopy [16], MRI [17], or both [18]. Yan et al. combined MRI radiomic and morphological features and reported an AUC of 0.962 in a testing cohort [19]. Liu et al. used three-dimensional convolutional neural networks to distinguish SIP from SIP-SCC, achieving a test AUC of 0.80 [14]. More recently, Ding et al. reported an external validation AUC of 0.859 for an MRI-based deep learning model [17]. Ren et al. combined nasal endoscopy and T2-weighted MRI with automated segmentation and achieved a test AUC of 0.865 [18]. These findings support quantitative image analysis, although performance estimates across studies are not directly comparable because the cohorts and evaluation methods differ.
The value of jointly integrating MRI, CT, and nasal endoscopy for differentiating SIP from SIP-SCC remains insufficiently characterized. This retrospective study therefore aimed to develop and evaluate a trimodal deep learning fusion framework combining patient-level predictions from MRI, CT, and endoscopy models without manual lesion segmentation. Its performance was compared with the unimodal models and participating clinicians.

2. Materials and Methods

2.1. Patients

This retrospective study included patients who underwent surgical treatment for sinonasal tumors at our center from October 2014 to August 2025 (Figure 1). The Institutional Review Board exempted informed consent requirements given the retrospective design of this study.
Figure 1. Patient recruitment flowchart. The unimodal networks were trained and validated using the development cohort and remained fixed during fusion analysis. Within the complete trimodal cohort, logistic regression was fitted on four folds and applied to the remaining fold. Predictions from all five held-out folds were combined to evaluate fusion performance. SIP = inverted papilloma, SIP-SCC = inverted papilloma-transformed squamous cell carcinomas, MRI = magnetic resonance imaging, CT = computed tomography, T1C = T1-weighted contrast-enhanced, and T2WI = T2-weighted imaging.
The inclusion criteria were as follows: (1) postoperative pathological diagnoses of SIP or SIP-SCC; (2) preoperative MRI and/or CT performed within 3 months before surgery at our center; and (3) preoperative nasal endoscopy performed within 3 months before surgery at our center with clear photos of the tumor. The exclusion criteria were as follows: (1) poor-quality endoscopic images or lack of clear photographs of the tumor site; (2) poor-quality CT/MRI images, significant motion artifacts, or artifacts caused by metallic dental prostheses; (3) prior chemotherapy or radiation therapy before MRI/CT examination; (4) maximum tumor diameter smaller than 10 mm; (5) concurrent other sinonasal malignancies; and (6) inconsistent diagnoses across multiple postoperative pathology reports.
The unimodal development cohort comprised 743 unique patients. Patients contributed available examinations to the relevant modality-specific datasets. A separate cohort of 106 patients had usable MRI, CT, and nasal endoscopy examinations acquired within three months before the same surgical procedure. These patients were excluded from unimodal network training and checkpoint selection. They were used for held-out evaluation of the unimodal networks and five-fold cross-validation of the fusion classifier.

2.2. Image Acquisition and Preprocessing

MRI examinations were predominantly performed at 3 T using a Verio scanner (Siemens Healthineers, Erlangen, Germany). Axial fat-suppressed contrast-enhanced T1-weighted (T1C) images were acquired using a volumetric interpolated breath-hold examination (VIBE) sequence, most commonly with a repetition time/echo time (TR/TE) of 3.73/1.48 ms, a flip angle of 9°, and a slice thickness of 3 mm. Axial fat-suppressed T2-weighted images (T2WI) were acquired using a turbo spin-echo sequence, most commonly with a TR/TE of 4460/101 ms, a slice thickness of 5 mm, and a center-to-center slice spacing of 5.75 mm. CT examinations were performed using a SOMATOM Definition Edge scanner (Siemens Healthineers, Forchheim, Germany). The most commonly used CT acquisition and reconstruction parameters were a tube voltage of 120 kVp, a slice thickness of 0.75 mm, and an H40s reconstruction kernel.
CT and MRI volumes were loaded from NIfTI files, with array axes reordered from (X, Y, Z) to (Z, Y, X). Intensities were clipped to fixed bounds and linearly normalized to [0, 1]. Volumes were resized to 40 × 100 × 100 using first-order interpolation, standardizing array dimensions rather than physical voxel spacing. Variable slice counts were handled by interpolation along the depth dimension, without individual slice selection or zero padding. No additional MRI registration or separate CT windowing was performed. Training augmentation consisted of random in-plane rotations selected from −20°, −10°, −5°, 5°, 10°, and 20°, with input dimensions preserved and identical rotations applied to both MRI channels. No random augmentation was applied during validation or testing. Each model processed the entire input volume to generate one score per patient, without slice-level voting or lesion segmentation masks.
Endoscopic imaging was performed with an IMAGE1 Superior 3-chip high-definition camera and Xenon Nova 175 light source (KARL STORZ SE & Co. KG, Tuttlingen, Germany). An otolaryngologist with 5 years of experience selected the most diagnostically representative photograph for each patient from the clinical reporting system. Endoscopic photographs were converted to RGB, resized to 224 × 224 using bilinear interpolation, and normalized to [0, 1] by dividing pixel values by 255. No additional standardization using channel means and standard deviations was applied. Training augmentation used random in-plane rotations from the same angle set with bilinear interpolation. Evaluation used one photograph per patient, without aggregation across photographs.

2.3. Unimodal DL Models

Figure 2 presents the overall study design and workflow. Three independent deep learning models were developed for MRI, CT, and endoscopy images, respectively. All unimodal models shared a similar framework comprising a ResNet-based feature extraction backbone (Module A), an optional fusion module (Module B), and a classification head (Module C). The CT and MRI models used custom three-dimensional ResNet-50 implementations, whereas the endoscopy model used a two-dimensional ResNet-18 with its final fully connected layer replaced by a single-output classification layer.
Figure 2. Schematic workflow of developing and validating models. 2D = two-dimensional, 3D = three-dimensional, SIP = inverted papilloma, SIP-SCC = inverted papilloma-transformed squamous cell carcinomas, T1C = T1-weighted contrast-enhanced, and T2WI = T2-weighted imaging.
For the MRI model, T1C and T2WI sequences served as dual inputs. The two sequences were preprocessed separately and stacked along the channel dimension before being passed to the MRI model. The input dimensions per sample were 2 × 40 × 100 × 100 for MRI, 1 × 40 × 100 × 100 for CT, and 3 × 224 × 224 for endoscopy. Each sequence was processed through separate ResNet encoders to extract sequence-specific features, which were then concatenated and passed through a fusion module before final classification. The CT model utilized thin-slice axial reconstructions as input, while the endoscopy model used nasal endoscopic photographs. Both CT and endoscopy models employed single-input pathways, where image features extracted by the ResNet backbone were directly fed to the classification head without intermediate fusion. Each unimodal dataset was randomly split into training and validation sets with a 4:1 ratio. All models were trained using binary cross-entropy loss to distinguish SIP-SCC from SIP. For each network, the checkpoint with the highest validation AUC was selected as the final unimodal model. The selected networks remained fixed during subsequent fusion analysis. For the endoscopy model, transfer learning from ImageNet pre-trained weights was applied to leverage prior knowledge from natural image domains. Models were optimized using the Adam optimizer. Several combinations of learning rate and batch size were evaluated on the development validation subsets. A learning rate of 5 × 10−4 and a batch size of 16 were selected based on validation performance and fixed for subsequent training and evaluation. The maximum number of training epochs was set to 300, with early stopping applied if validation loss showed no improvement (>1 × 10−4) over 30 consecutive epochs.

2.4. Trimodal Fusion Model

The fusion cohort comprised 106 patients with usable MRI, CT, and nasal endoscopy data acquired within three months before the same surgical procedure. These patients were excluded from unimodal network training and checkpoint selection. The trained unimodal networks remained fixed and generated one probability score for SIP-SCC per modality for each patient. The three scores from the same patient served as inputs to a logistic regression classifier. No missing-modality imputation was required. The fusion classifier was fitted and evaluated using five-fold cross-validation within this cohort. In each iteration, the regression coefficients and intercept were estimated using four folds, and the fitted classifier generated predictions for the remaining fold. This procedure yielded one out-of-fold (OOF) fusion prediction per patient. Predictions from all five held-out folds were pooled to evaluate fusion performance. AUC was calculated from the pooled OOF probabilities. Accuracy, sensitivity, specificity, and F1 score were calculated at the fixed probability threshold of 0.5 for the primary analysis.
For an exploratory analysis, an additional threshold was selected by maximizing the Youden index (sensitivity + specificity − 1) using the pooled OOF predictions and corresponding outcomes. Performance at this threshold was reported separately because threshold selection and evaluation used the same patients. All performance estimates were reported with 95% confidence intervals.

2.5. Reader Study

To provide a clinical reference for model performance, six otolaryngologists from our center participated in the reader study, including three junior physicians with less than 3 years of clinical experience and three senior physicians with more than 10 years of clinical experience. Each reader independently evaluated all 106 test cases using the same three modalities (MRI, CT, endoscopy) as the trimodal fusion model, providing SIP/SIP-SCC diagnoses. Readers were blinded to pathological diagnoses, trimodal fusion model predictions, and diagnoses of other readers. Group-level performance was calculated from the majority-vote classifications of the three readers in each group and reported as point estimates.

2.6. Statistical Analysis

Statistical analyses were performed using R (version 4.4.1). Continuous and categorical variables were compared using t-test and chi-square test, respectively. Model performance was assessed using AUC, accuracy, sensitivity, specificity, and F1 score. Classification metrics were calculated at the fixed threshold of 0.5 for the primary analysis. Results at the Youden-selected threshold were considered exploratory. Pairwise comparisons of AUCs between the fusion model and the three unimodal models were performed using DeLong’s test. p values were adjusted using the Holm method within this family of three comparisons. McNemar’s test was used to compare classification accuracy between the fusion model and each of the six individual readers and the two reader-group majority-vote classifications. p values were adjusted using the Holm method within this family of eight comparisons. Both unadjusted and Holm-adjusted p values are reported. A two-sided Holm-adjusted p value < 0.05 was considered statistically significant.

3. Results

3.1. Patient Characteristics

A total of 849 patients who underwent surgery for SIP/SIP-SCC at our center were included in this retrospective study. Among these, 106 (SIP 81, SIP-SCC 25) had complete trimodal imaging (MRI, CT, and endoscopy), while 743 (SIP 533, SIP-SCC 210) had one or two modalities available. For unimodal model development, patients were grouped based on imaging availability: MRI model (n = 463: SIP 320, SIP-SCC 143), CT model (n = 527: SIP 337, SIP-SCC 190), and endoscopy model (n = 605: SIP 454, SIP-SCC 151). The clinical characteristics of all patients are summarized in Table 1.
Table 1. Clinical characteristics of study participants.

3.2. Performance of Unimodal DL Models

All unimodal models converged within 300 epochs, with early stopping applied based on validation performance. The MRI model trained for 126 epochs, achieving excellent training performance (accuracy: 98.4%, AUC: 0.999) with well-maintained validation performance (accuracy: 89.1%, AUC: 0.860). The endoscopy model converged rapidly (29 epochs) with similarly strong training metrics (accuracy: 99.2%, AUC: 1.000) and validation accuracy of 84.3% (AUC: 0.808). In contrast, the CT model showed the weakest performance, converging after 31 epochs with validation accuracy of 67.6% and AUC of 0.613.
The MRI model performed best on the independent test set (Table 2), with an AUC of 0.859 (95% CI: 0.774–0.932), accuracy of 80.2% (72.6–87.7%), sensitivity of 80.0% (61.9–95.0%), and specificity of 80.3% (71.6–88.8%). The endoscopy model achieved an AUC of 0.813 (95% CI: 0.709–0.906) and accuracy of 82.1% (74.5–88.7%). Specificity of the endoscopy model was highest among unimodal models at 88.9% (81.6–95.1%), but sensitivity was lowest at 60.0% (40.7–78.9%). The CT model showed the lowest AUC at 0.634 (95% CI: 0.502–0.759) and the poorest accuracy of 53.8% (44.3–63.2%). Sensitivity was 76.0% (57.6–91.3%), but specificity was only 46.9% (36.8–58.2%).
Table 2. Diagnostic performance comparison of unimodal and trimodal fusion models in the complete trimodal cohort.
Performance on the validation and test sets was comparable across modalities, suggesting stable generalization. MRI validation AUC (0.860) and test AUC (0.859) differed by only 0.1 percentage point, and endoscopy showed similarly consistent performance (validation AUC: 0.808 vs. test AUC: 0.813).

3.3. Performance of the Trimodal Fusion Model

The logistic regression fusion model achieved the highest observed AUC among the evaluated models (Table 2 and Figure 3). The learned regression coefficients were 2.451 for MRI, 1.970 for endoscopy, and 1.219 for CT (Figure 4A). All three coefficients were positive, indicating that higher modality-specific probability scores increased the predicted probability of SIP-SCC when the other inputs were held constant. The model intercept was −2.585.
Figure 3. Unimodal model performance and attention visualization. (A) ROC curves of MRI, CT, and endoscopy models for differentiating SIP and SIP-SCC on the independent test set. (B) Attention maps overlaid on SIP and SIP-SCC cases across imaging modalities (T1C and T2WI for MRI, CT, and endoscopy). AUC = area under the receiver operating characteristic curve, ROC = receiver operating characteristic, SIP = inverted papilloma, SIP-SCC = inverted papilloma-transformed squamous cell carcinomas, FPR = false positive rate, and TPR = true positive rate.
Figure 4. Trimodal fusion model interpretability and performance. (A) Logistic regression coefficients for the MRI, endoscopy, and CT probability scores. (B) Classification metrics at the primary threshold of 0.5 and exploratory Youden threshold of 0.610. Metrics at 0.610 may be optimistic because the threshold was selected and evaluated using the same pooled out-of-fold predictions. (C) Calibration curves with Brier scores demonstrating prediction reliability across models. (D) ROC curves comparing discriminative ability of unimodal and trimodal fusion models. AUC = area under the receiver operating characteristic curve, OOF = out of fold, ROC = receiver operating characteristic, FPR = false positive rate, and TPR = true positive rate.
The fusion model achieved an AUC of 0.910. Compared with the unimodal models, the AUC difference was statistically significant for CT (0.634; unadjusted p < 0.001; Holm-adjusted p < 0.001) and endoscopy (0.813; unadjusted p = 0.023; Holm-adjusted p = 0.045), but not for MRI (0.859; unadjusted and adjusted p = 0.142). At the fixed probability threshold of 0.5, the fusion model achieved an accuracy of 83.0% (95% CI, 76.4–89.6%), a sensitivity of 76.0% (95% CI, 58.3–91.7%), and a specificity of 85.2% (95% CI, 77.5–92.2%). The F1 score was 0.679 (95% CI, 0.520–0.800). In an exploratory analysis, a threshold of 0.610 (Figure 4B) selected using the Youden index yielded an accuracy of 89.6% (95% CI: 84.0–95.3%), a sensitivity of 76.0% (95% CI: 58.3–92.9%), and a specificity of 93.8% (95% CI: 88.2–98.6%). These estimates were obtained from the same out-of-fold predictions used to select the threshold and may therefore be optimistic.
Calibration analysis using Brier score quantified prediction reliability (Figure 4C). Lower Brier scores indicate better agreement between predicted probabilities and observed outcomes. The fusion model had the lowest Brier score (0.119), compared with endoscopy (0.148), MRI (0.163), and CT (0.345). Calibration curves showed that the fusion model maintained well-calibrated probabilities, while unimodal models tended to over- or underestimate at the extremes. ROC curve analysis (Figure 4D) demonstrated substantial differences in discriminative ability across imaging modalities. The fusion model achieved an AUC of 0.910, significantly higher than those of endoscopy (0.813, p = 0.023) and CT (0.634, p < 0.001). The difference from MRI (0.859) was not statistically significant (p = 0.142).

3.4. Exploratory Analysis by Previous Resection Status

In the 106-patient complete trimodal cohort, previous resection was recorded in 30 of 81 patients with SIP (37.0%) and 16 of 25 patients with SIP-SCC (64.0%) (Table 1). In the exploratory analysis at the fixed probability threshold of 0.5, the model achieved an accuracy of 83.3% (95% CI, 71.5–91.7%), a sensitivity of 66.7% (95% CI, 29.9–92.5%), a specificity of 86.3% (95% CI, 73.7–94.3%), and an AUC of 0.861 (95% CI, 0.699–0.983) among patients without previous resection. Among patients with previous resection, the corresponding values were 82.6% (95% CI, 68.6–92.2%), 81.3% (95% CI, 54.4–96.0%), 83.3% (95% CI, 65.3–94.4%), and 0.931 (95% CI, 0.846–0.988) (Table 3). The model produced 7 false-positive and 3 false-negative classifications among patients without previous resection, and 5 false-positive and 3 false-negative classifications among those with previous resection. The between-group comparison was not statistically significant (p = 0.405).
Table 3. Analysis of fusion model performance by previous resection status.
Among patients with SIP, predicted probabilities were similar between those without and with previous resection. The median predicted probability was 0.223 (IQR, 0.154–0.339) in patients without previous resection and 0.210 (IQR, 0.158–0.376) in those with previous resection (Mann–Whitney U = 769, p = 0.973). When previous resection alone was used as a binary predictor of SIP-SCC in the complete trimodal cohort, the AUC was 0.635 (95% CI, 0.524–0.740), with a sensitivity of 64.0% (95% CI, 42.5–82.0%) and a specificity of 63.0% (95% CI, 51.5–73.4%). These exploratory subgroup estimates should be interpreted cautiously, given the small number of SIP-SCC cases in each resection stratum.

3.5. Reader Study

Six physicians independently evaluated all 106 trimodal cases (Table 4 and Figure 5). At the fixed threshold of 0.5, the fusion model achieved an accuracy of 83.0%. The junior-reader group majority vote had an accuracy of 64.2% (unadjusted p = 0.004; Holm-adjusted p = 0.022), whereas the senior-reader group majority vote had an accuracy of 81.1% (unadjusted p = 0.860; Holm-adjusted p = 1.000). After Holm correction, differences from individual readers remained statistically significant for Reader 1 (unadjusted p < 0.001; adjusted p = 0.004) and Reader 3 (unadjusted p = 0.002; adjusted p = 0.011). Differences from the other individual readers were not statistically significant after adjustment.
Table 4. Performance of readers compared with trimodal fusion model.
Figure 5. Trimodal fusion model performance compared with readers and classification outcomes of models. (A) ROC curve of the fusion model for SIP versus SIP-SCC differentiation on the test cohort, with individual physician operating points superimposed. (B) Classification results on the independent test set for MRI, CT, endoscopy, and trimodal fusion models (threshold of 0.5). 0 = SIP, 1 = SIP-SCC. ACC = accuracy, OOF = out of fold, ROC = receiver operating characteristic, FPR = false positive rate, and TPR = true positive rate.

4. Discussion

This study evaluated a trimodal deep learning fusion framework integrating MRI, CT, and nasal endoscopy for preoperative differentiation between SIP and SIP-SCC. The fusion model achieved an out-of-fold AUC of 0.910 and an accuracy of 83.0% at the fixed threshold of 0.5. Its AUC was significantly higher than those of CT and endoscopy, but not MRI. Its accuracy was within the range observed among senior physicians, with no statistically significant differences from individual senior readers. These findings support further evaluation of the framework as an adjunct to preoperative assessment.
Preoperative differentiation between SIP and SIP-SCC is clinically important. Failure to detect SIP-SCC may lead to inadequate resection and recurrence. Conversely, misdiagnosing SIP as malignant can result in unnecessarily aggressive surgery [20,21,22]. Previous studies have established the feasibility of quantitative MRI analysis for identifying SIP-SCC. Yan et al. combined radiomic and morphological features, achieving a test AUC of 0.962 and demonstrating the value of combining quantitative image features with conventional imaging assessment [19]. Xia et al. also combined multiparametric MRI radiomic features with clinical risk factors to predict malignant transformation, illustrating another approach to integrating imaging and clinical information [13]. The systematic review by Waters et al. provides a broader synthesis of radiomics research specifically addressing malignant transformation of SIP [2]. Liu et al. investigated three-dimensional convolutional neural networks in 90 patients from two institutions and reported a test AUC of 0.80 [14]. This study provided evidence that volumetric MRI information could support automated classification, although the sample size limited the strength of the performance estimates. More recently, Ding et al. reported an external validation AUC of 0.859 for an MRI-based deep learning model [17]. External validation and assessment of radiologists with model assistance were strengths of that study. Ren et al. extended this work by integrating nasal endoscopy and T2-weighted MRI, achieving a test AUC of 0.865 in a cohort of 174 patients [18]. Their use of automated segmentation addressed an important practical limitation of approaches requiring manual tumor delineation at prediction. However, MRI classification used the largest tumor slice, and CT was not included.
The broader potential of these approaches is supported by a systematic review and meta-analysis of 17 studies involving 3321 participants. Models combining radiomic and clinical features achieved pooled validation sensitivity and specificity of 0.85 and 0.87, respectively, for distinguishing SIP from malignant sinonasal tumors [23]. These findings support further investigation of quantitative imaging approaches, although differences in diagnostic targets, patient selection, imaging inputs, and validation designs limit direct comparisons across studies. Our framework combines patient-level predictions from MRI, CT, and nasal endoscopy models. The MRI and CT models process entire volumes resized to fixed input dimensions, while the endoscopy model processes individual photographs, without requiring manual lesion segmentation. Evaluation in the same patients allowed direct comparisons between the unimodal and fusion models. MRI achieved the highest unimodal AUC of 0.859. Fusion increased the AUC numerically to 0.910, but the difference from MRI was not statistically significant (p = 0.142).
Unimodal performance varied considerably across modalities. Gu et al. demonstrated the potential of combining MRI radiomic and clinical–radiological features for distinguishing SIP from malignant sinonasal tumors [24]. In our study, MRI achieved the highest unimodal AUC (0.859), potentially owing to its soft-tissue contrast and complementary information from T1C and T2WI. The convoluted cerebriform pattern of SIP on these sequences reflects its alternating epithelial and stromal architecture. Focal loss of this pattern and associated necrosis, both reported in SIP-SCC, may contribute to MRI-based discrimination [9]. CT showed limited standalone performance (AUC: 0.634). Although bone destruction may indicate invasive carcinoma, benign SIP can also produce bone remodeling and erosion. This overlap may partly explain the limited discrimination of the CT model [12,25]. Adding CT to MRI and endoscopy yielded a small numerical improvement, but the direct comparison did not demonstrate a statistically significant incremental diagnostic benefit in this cohort. Kwon et al. demonstrated the feasibility of endoscopic image classification using data from 17 hospitals, distinguishing normal findings, nasal polyps, benign tumors, and malignant tumors [26]. Our endoscopy model showed high specificity (88.9%) but lower sensitivity (60.0%), likely reflecting focal malignant transformation within predominantly benign lesions of SIP-SCC [5,6,7,27,28,29,30]. Endoscopy directly depicts surface features such as ulceration and necrosis, which may complement MRI and CT findings. The fusion model combined predictions from modalities depicting internal tumor architecture, bone involvement, and surface morphology. At the fixed threshold of 0.5, it achieved a specificity of 85.2% and a sensitivity of 76.0%. These findings support further evaluation of its potential to inform treatment decisions and support preoperative diagnostic assessment.
The reader study provided a clinical reference for model performance through comparisons with physicians assessing the same patients. At the fixed threshold of 0.5, the fusion model achieved an accuracy of 83.0%, within the range observed among senior physicians (74.5% to 86.8%). Differences from individual senior physicians were not statistically significant. By combining predictions from multiple imaging modalities, the model may provide an additional source of information for preoperative assessment.
This study has several limitations. First, the retrospective single-center design limits generalizability. Imaging protocols, patient populations, and disease characteristics may differ across institutions. Prospective multicenter validation is needed to assess model performance in diverse clinical settings. Second, the sample size, while reasonable for this rare disease SIP-SCC, remains modest by general deep learning standards, particularly for the trimodal fusion cohort (n = 106). Previous resection may alter imaging appearances and influence model predictions, but the small number of cases in each subgroup of the complete trimodal cohort limited our ability to assess this potential effect. Larger datasets would enable a more robust estimation of performance metrics and potentially support more complex fusion architectures. Third, while the trimodal fusion model demonstrates strong performance and the learned fusion weights offer some transparency, it remains a “black box” with limited interpretability.

5. Conclusions

This trimodal deep learning fusion framework integrated preoperative MRI, CT, and nasal endoscopy for differentiating SIP from SIP-SCC. It achieved a numerically higher AUC than each unimodal model, with accuracy within the range observed among senior physicians. These findings support its potential as a diagnostic support tool. Larger, independent cohorts are needed to establish generalizability and obtain more precise performance estimates.

Author Contributions

Conceptualization, X.Z., W.G. and H.Y.; methodology, X.Z. and W.G.; software, Z.L.; validation, X.Z., W.G. and Z.C.; formal analysis, X.Z. and Z.L.; data curation, W.G., X.L. and Z.C.; writing—original draft preparation, X.Z. and W.G.; writing—review and editing, X.L., Y.S., L.W., W.L. and H.Y.; visualization, X.Z. and Z.L.; supervision, Y.S., L.W., W.L. and H.Y.; project administration, L.W., W.L. and H.Y.; funding acquisition, W.L. and H.Y. All authors have read and agreed to the published version of the manuscript.

Funding

This work was sponsored by the National Natural Science Foundation of China (82371123, 82301276); Shanghai Science and Technology Committee Foundation (23Y31900500); National Key Clinical specialty construction project (Z155080000004); the New Technologies of Endoscopic Surgery in Skull Base Tumor: CAMS Innovation Fund for Medical Sciences (CIFMS) (2019-I2M-5-003); and Shanghai Sailing Program (23YF140480, 24YF2745500).

Institutional Review Board Statement

This retrospective study was approved by the Institutional Ethics Committee of the Eye and ENT Hospital of Fudan University on 29 October 2025, under approval number IIT2025267. The study was conducted in accordance with the principles of the Declaration of Helsinki.

Data Availability Statement

The datasets generated and/or analysed during the current study are available from the corresponding authors on reasonable request. All figures and tables are original and were prepared by the authors for this study. Clinical images were obtained from the study cohort. No figures or tables were reproduced or adapted from previously published material.

Acknowledgments

OpenAI Codex (GPT-6) was used exclusively for language editing. No AI tools were used for the generation of scientific content, data analysis, or interpretation. The authors take full responsibility for the accuracy and integrity of the manuscript.

Conflicts of Interest

The authors declare that they have no competing interests related to this work. No financial or non-financial relationships exist that could be construed as potential conflicts of interest.

References

  1. Viitasalo, S.; Ilmarinen, T.; Aaltonen, L.M.; Hagström, J.; Hytönen, M.; Hammarén-Malmi, S.; Pietarinen, P.; Järvenpää, P.; Kinnari, T.; Geneid, A.; et al. Sinonasal inverted papilloma—Malignant transformation and non-sinonasal malignancies. Laryngoscope 2023, 133, 506–511. [Google Scholar] [CrossRef] [Scilit]
  2. Waters, C.; Deshwal, A.; Cuddihy, T.O.; Jones, H.; Temperley, H.C.; Kaye-Coyle, H.; O’Sullivan, N.J.; Mac Curtain, B.M.; Kelly, M.E.; Young, O. Role of Radiomics to Predict Malignant Transformation of Sinonasal Inverted Papilloma: A Systematic Review. Cancers 2025, 17, 2175. [Google Scholar] [CrossRef] [Scilit]
  3. Mirza, S.; Bradley, P.J.; Acharya, A.; Stacey, M.; Jones, N.S. Sinonasal inverted papillomas: Recurrence, and synchronous and metachronous malignancy. J. Laryngol. Otol. 2007, 121, 857–864. [Google Scholar] [CrossRef] [Scilit]
  4. Thawani, R.; Kim, M.S.; Arastu, A.; Feng, Z.; West, M.T.; Taflin, N.F.; Thein, K.Z.; Li, R.; Geltzeiler, M.; Lee, N.; et al. The contemporary management of cancers of the sinonasal tract in adults. CA Cancer J. Clin. 2023, 73, 72–112. [Google Scholar] [CrossRef] [Scilit]
  5. Han, M.W.; Lee, B.J.; Jang, Y.J.; Chung, Y.S. Clinical value of office-based endoscopic incisional biopsy in diagnosis of nasal cavity masses. Otolaryngol. Head Neck Surg. 2010, 143, 341–347. [Google Scholar] [CrossRef] [Scilit]
  6. Schreiber, A.; Rampinelli, V.; Ferrari, M.; Mattavelli, D.; Farina, D.; Battocchio, S.; Nicolai, P. Diagnostic reliability of pretreatment biopsy in malignant nasoethmoidal tumors: A retrospective study of 77 cases. Laryngoscope 2018, 128, 1772–1777. [Google Scholar] [CrossRef] [Scilit]
  7. Ganti, A.; Tajudeen, B.A.; Plitt, M.A.; Rossi, I.; Gattuso, P.; Batra, P.S. Discordance in Preoperative and Postoperative Histopathology of Sinonasal Tumors. Am. J. Rhinol. Allergy 2018, 32, 101–105. [Google Scholar] [CrossRef] [Scilit]
  8. Jeon, T.Y.; Kim, H.J.; Chung, S.K.; Dhong, H.J.; Kim, H.Y.; Yim, Y.J.; Kim, S.T.; Jeon, P.; Kim, K.H. Sinonasal inverted papilloma: Value of convoluted cerebriform pattern on MR imaging. AJNR Am. J. Neuroradiol. 2008, 29, 1556–1560. [Google Scholar] [CrossRef] [Scilit]
  9. Suh, C.H.; Lee, J.H.; Chung, M.S.; Xu, X.Q.; Sung, Y.S.; Chung, S.R.; Choi, Y.J.; Baek, J.H. MRI Predictors of Malignant Transformation in Patients with Inverted Papilloma: A Decision Tree Analysis Using Conventional Imaging Features and Histogram Analysis of Apparent Diffusion Coefficients. Korean J. Radiol. 2021, 22, 751–758. [Google Scholar] [CrossRef] [Scilit]
  10. Umeda, M.; Kuroki, M.; Kato, H.; Shibata, H.; Yamada, N.; Okuda, H.; Terazawa, K.; Iinuma, R.; Ohkoshi, A.; Wakamori, S.; et al. CT scoring system for differentiating of sinonasal inverted papilloma and squamous cell carcinoma arising from inverted papilloma. Eur. Arch. Oto-Rhino-Laryngol. 2025, 282, 2533–2538. [Google Scholar] [CrossRef] [Scilit]
  11. Lee, D.K.; Chung, S.K.; Dhong, H.J.; Kim, H.Y.; Kim, H.J.; Bok, K.H. Focal hyperostosis on CT of sinonasal inverted papilloma as a predictor of tumor origin. AJNR Am. J. Neuroradiol. 2007, 28, 618–621. [Google Scholar]
  12. Yan, C.H.; Tong, C.C.L.; Penta, M.; Patel, V.S.; Palmer, J.N.; Adappa, N.D.; Nayak, J.V.; Hwang, P.H.; Patel, Z.M. Imaging predictors for malignant transformation of inverted papilloma. Laryngoscope 2019, 129, 777–782. [Google Scholar] [CrossRef] [Scilit]
  13. Xia, Z.; Lin, N.; Chen, W.; Qi, M.; Sha, Y. Multiparametric MRI-based radiomics nomogram for predicting malignant transformation of sinonasal inverted papilloma. Clin. Radiol. 2024, 79, e408–e416. [Google Scholar] [CrossRef] [Scilit]
  14. Liu, G.S.; Yang, A.; Kim, D.; Hojel, A.; Voevodsky, D.; Wang, J.; Tong, C.C.L.; Ungerer, H.; Palmer, J.N.; Kohanski, M.A.; et al. Deep learning classification of inverted papilloma malignant transformation using 3D convolutional neural networks and magnetic resonance imaging. Int. Forum Allergy Rhinol. 2022, 12, 1025–1033. [Google Scholar] [CrossRef] [Scilit]
  15. He, S.; Zhao, Y.; Shi, L.; Yang, X.; Wang, X.; Luo, Y.; Wang, M.; Zhang, X.; Li, X.; Yu, D.; et al. Utilizing radiomics for differential diagnosis of inverted papilloma and chronic rhinosinusitis with polyps based on unenhanced CT scans. Sci. Rep. 2024, 14, 19299. [Google Scholar] [CrossRef] [Scilit]
  16. Levi, L.; Ye, K.; Fieux, M.; Renteria, A.; Lin, S.; Xing, L.; Ayoub, N.F.; Patel, Z.M.; Nayak, J.V.; Hwang, P.H.; et al. Machine Learning of Endoscopy Images to Identify, Classify, and Segment Sinonasal Masses. Int. Forum Allergy Rhinol. 2025, 15, 524–535. [Google Scholar] [CrossRef] [Scilit]
  17. Ding, C.; Wen, B.; Han, Q.; Hu, N.; Kang, Y.; Wang, Y.; Wang, C.; Zhang, L.; Xian, J. Preoperative prediction of malignant transformation in sinonasal inverted papilloma: A novel MRI-based deep learning approach. Eur. Radiol. 2025, 35, 6160–6170. [Google Scholar] [CrossRef] [Scilit]
  18. Ren, J.; Ren, Z.; Zhang, D.; Yuan, Y.; Qi, M. Deep learning using nasal endoscopy and T2-weighted MRI for prediction of sinonasal inverted papilloma-associated squamous cell carcinoma: An exploratory study. Eur. Radiol. Exp. 2025, 9, 68. [Google Scholar] [CrossRef] [Scilit]
  19. Yan, Y.; Liu, Y.; Tao, J.; Li, Z.; Qu, X.; Guo, J.; Xian, J. Preoperative Prediction of Malignant Transformation of Sinonasal Inverted Papilloma Using MR Radiomics. Front. Oncol. 2022, 12, 870544. [Google Scholar] [CrossRef] [Scilit]
  20. Brown, N.A.; Plouffe, K.R.; Yilmaz, O.; Weindorf, S.C.; Betz, B.L.; Carey, T.E.; Seethala, R.R.; McHugh, J.B.; Tomlins, S.A.; Udager, A.M. TP53 mutations and CDKN2A mutations/deletions are highly recurrent molecular alterations in the malignant progression of sinonasal papillomas. Mod. Pathol. 2021, 34, 1133–1142. [Google Scholar] [CrossRef] [Scilit]
  21. Weindorf, S.C.; Brown, N.A.; McHugh, J.B.; Udager, A.M. Sinonasal Papillomas and Carcinomas: A Contemporary Update With Review of an Emerging Molecular Classification. Arch. Pathol. Lab. Med. 2019, 143, 1304–1316. [Google Scholar] [CrossRef] [Scilit]
  22. Long, C.; Jabarin, B.; Harvey, A.; Ham, J.; Javer, A.; Janjua, A.; Thamboo, A. Clinical evidence based review and systematic scientific review in the identification of malignant transformation of inverted papilloma. J. Otolaryngol. Head Neck Surg. 2020, 49, 25. [Google Scholar] [CrossRef] [Scilit]
  23. Qin, X.; Shi, J.; Zhao, X.; Zhang, Y.; Liu, X.; Wang, L. Identifying sinonasal inverted papilloma by machine learning: A systematic review and meta-analysis. Front. Oncol. 2025, 15, 1628999. [Google Scholar] [CrossRef] [Scilit]
  24. Gu, J.; Yu, Q.; Li, Q.; Peng, J.; Lv, F.; Gong, B.; Zhang, X. MRI radiomics-based machine learning model integrated with clinic-radiological features for preoperative differentiation of sinonasal inverted papilloma and malignant sinonasal tumors. Front. Oncol. 2022, 12, 1003639. [Google Scholar] [CrossRef] [Scilit]
  25. Zhang, L.; Fang, G.; Yu, W.; Yang, B.; Wang, C.; Zhang, L. Prediction of malignant sinonasal inverted papilloma transformation by preoperative computed tomography and magnetic resonance imaging. Rhinology 2020, 58, 248–256. [Google Scholar] [CrossRef] [Scilit]
  26. Kwon, K.W.; Park, S.H.; Lee, D.H.; Kim, D.Y.; Park, I.H.; Cho, H.J.; Kim, J.S.; Kim, J.Y.; Hong, S.D.; Kim, S.A.; et al. Deep learning algorithm for the automated detection and classification of nasal cavity mass in nasal endoscopic images. PLoS ONE 2024, 19, e0297536. [Google Scholar] [CrossRef] [Scilit]
  27. Tuşaliu, M.; Mogoantă, C.A.; Iancu, C.; Iovănescu, D.; Niţescu, M.; Bucur, C.; Perpelea, A.C.; Cîmpeanu, O.L.; Palade, O.D. Sinonasal inverted papilloma from diagnosis to treatment—A narrative review. Rom. J. Morphol. Embryol. 2024, 65, 599–607. [Google Scholar] [CrossRef] [Scilit]
  28. Ren, Y.; Fang, G.; Wang, K.; Yan, B.; Wang, C. The diagnostic value of image-enhanced endoscopy system in sinonasal inverted papilloma. Eur. Arch. Otorhinolaryngol. 2024, 281, 4221–4230. [Google Scholar] [CrossRef] [Scilit]
  29. Benchetrit, L.; Thomson, E.; Paz-Lansberg, M.; Platt, M.P.; Brook, C.D. Evaluation of narrow-band imaging in the diagnosis of sinonasal inverted papilloma. Int. Forum Allergy Rhinol. 2024, 14, 720–723. [Google Scholar] [CrossRef] [Scilit]
  30. Yui, R.; Takahashi, M.; Noda, K.; Yoshida, K.; Sakurai, R.; Ohira, S.; Omura, K.; Otori, N.; Wada, K.; Kojima, H. Preoperative prediction of sinonasal papilloma by artificial intelligence using nasal video endoscopy: A retrospective study. Sci. Rep. 2023, 13, 12439. [Google Scholar] [CrossRef] [Scilit]
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.