MDPI Contact

MDPI AG
St. Alban-Anlage 66,
4052 Basel, Switzerland
Support contact
Tel. +41 61 683 77 34
Fax: +41 61 302 89 18

For more contact information, see here.

Advanced Search

You can use * to search for partial matches.

Search Results

4 articles matched your search query. Search Parameters:
Keywords = potassium ion selective electrode

Matches by word:

POTASSIUM (545) , ION (2080) , SELECTIVE (2085) , ELECTRODE (1205)

View options
order results:
result details:
results per page:
Articles per page View Sort by
Displaying article 1-50 on page 1 of 1.
Export citation of selected articles as:
Open AccessArticle Nitrate Ion Selective Electrode Based on Ion Imprinted Poly(N-methylpyrrole)
Chemosensors 2017, 5(1), 2; doi:10.3390/chemosensors5010002
Received: 7 October 2016 / Revised: 12 December 2016 / Accepted: 12 December 2016 / Published: 4 January 2017
Viewed by 628 | PDF Full-text (2304 KB) | HTML Full-text | XML Full-text
Abstract
A poly(N-methylpyrrole) based ion selective electrode (ISE) has been prepared by electro-polymerization of N-methylpyrrole using potassium nitrate as the supporting electrolyte. Electrochemical and chemical variables were used to optimize the potentiometric response of the electrodes and to maximize the selectivity
[...] Read more.
A poly(N-methylpyrrole) based ion selective electrode (ISE) has been prepared by electro-polymerization of N-methylpyrrole using potassium nitrate as the supporting electrolyte. Electrochemical and chemical variables were used to optimize the potentiometric response of the electrodes and to maximize the selectivity for nitrate over potential interferences. The selectivity, longevity and stability of the ion-imprinted polymer give this electrode advantages over traditional nitrate ISEs. The best prototype electrode exhibits a linear potential response to nitrate ion within the concentration range of 5.0 × 10−6 to 0.1 M nitrate with a near Nernstian slope of −56.3 mV per decade (R2 = 0.9998) and a strong preference for the nitrate ion over other anions. The selectivity coefficients of the electrode were evaluated by the fixed interference method. The use of N-methylpyrrole has advantages over pyrrole in terms of selectivity and pH insensitivity. Full article
Figures

Figure 1

Open AccessArticle Chemical Sensor Platform for Non-Invasive Monitoring of Activity and Dehydration
Sensors 2015, 15(1), 1479-1495; doi:10.3390/s150101479
Received: 14 November 2014 / Accepted: 29 December 2014 / Published: 14 January 2015
Cited by 4 | Viewed by 1766 | PDF Full-text (2412 KB) | HTML Full-text | XML Full-text
Abstract
A non-invasive solution for monitoring of the activity and dehydration of organisms is proposed in the work. For this purpose, a wireless standalone chemical sensor platform using two separate measurement techniques has been developed. The first approach for activity monitoring is based on
[...] Read more.
A non-invasive solution for monitoring of the activity and dehydration of organisms is proposed in the work. For this purpose, a wireless standalone chemical sensor platform using two separate measurement techniques has been developed. The first approach for activity monitoring is based on humidity measurement. Our solution uses new humidity sensor based on a nanostructured TiO2 surface for sweat rate monitoring. The second technique is based on monitoring of potassium concentration in urine. High level of potassium concentration denotes clear occurrence of dehydration. Furthermore, a Wireless Body Area Network (WBAN) was developed for this sensor platform to manage data transfer among devices and the internet. The WBAN coordinator controls the sensor devices and collects and stores the measured data. The collected data is particular to individuals and can be shared with physicians, emergency systems or athletes’ coaches. Long-time monitoring of activity and potassium concentration in urine can help maintain the appropriate water intake of elderly people or athletes and to send warning signals in the case of near dehydration. The created sensor system was calibrated and tested in laboratory and real conditions as well. The measurement results are discussed. Full article
Figures

Open AccessArticle Multichannel Boron Doped Nanocrystalline Diamond Ultramicroelectrode Arrays: Design, Fabrication and Characterization
Sensors 2012, 12(6), 7669-7681; doi:10.3390/s120607669
Received: 24 April 2012 / Revised: 23 May 2012 / Accepted: 4 June 2012 / Published: 7 June 2012
Cited by 24 | Viewed by 3538 | PDF Full-text (367 KB) | HTML Full-text | XML Full-text
Abstract
We report on the fabrication and characterization of an 8 × 8 multichannel Boron Doped Diamond (BDD) ultramicro-electrode array (UMEA). The device combines both the assets of microelectrodes, resulting from conditions in mass transport from the bulk solution toward the electrode, and of
[...] Read more.
We report on the fabrication and characterization of an 8 × 8 multichannel Boron Doped Diamond (BDD) ultramicro-electrode array (UMEA). The device combines both the assets of microelectrodes, resulting from conditions in mass transport from the bulk solution toward the electrode, and of BDD’s remarkable intrinsic electrochemical properties. The UMEAs were fabricated using an original approach relying on the selective growth of diamond over pre-processed 4 inches silicon substrates. The prepared UMEAs were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The results demonstrated that the electrodes have exhibited a very fast electrode transfer rate (k0) up to 0.05 cm∙s−1 (in a fast redox couple) and on average, a steady state limiting current (in a 0.5 M potassium chloride aqueous solution containing 1 mM Fe(CN)64− ion at 100 mV∙s−1) of 1.8 nA. The UMEAs are targeted for electrophysiological as well as analytical applications. Full article
(This article belongs to the Section Biosensors)
Figures

Open AccessArticle Characterization of All Solid State Hydrogen Ion Selective Electrode Based on PVC-SR Hybrid Membranes
Sensors 2003, 3(6), 192-201; doi:10.3390/s30600192
Received: 27 March 2003 / Accepted: 8 May 2003 / Published: 30 June 2003
Cited by 7 | Viewed by 4648 | PDF Full-text (618 KB) | HTML Full-text | XML Full-text
Abstract
Hydrogen ion selective membranes formulated with 3140 RTV silicone rubber (SR) in PVC were studied to extend the life time of solid state ion sensors through improved membrane adhesion. All solid state hydrogen ion selective electrodes were prepared by incorporation of tridodecyl amine
[...] Read more.
Hydrogen ion selective membranes formulated with 3140 RTV silicone rubber (SR) in PVC were studied to extend the life time of solid state ion sensors through improved membrane adhesion. All solid state hydrogen ion selective electrodes were prepared by incorporation of tridodecyl amine (TDDA) as an ionophore, potassium tetrakis[3.5-bis(p-chlorophenyl)borate (KTpClPB) as a lipophilic additive, bis(2-ethylhexyl)adipate (DOA) as a plasticizer. Their linear dynamic range was pH 2.0-11.0 and showed the near Nernstian slope of 55.1±0.2 mV/pH (r=0.999). The ifluences from alkali and alkaline earth metal ions were studied for the response of the final ISE membrane composition. Impedance spectroscopic data showed that the resistance was increased by increasing SR content in PVC. Brewster Angle Microscopy (BAM) image showed clear differences according to the SR compositions in PVC. Life time of the all solid state membrane electrode was extended to about 2 months by preparing the membrane with PVC and SR. The standard reference material from NIST (2181 HEPES Free acid and 2182 NaHEPESate) was tested for the ISE and it gave good result. Full article

Years

Subjects

Refine Subjects

Journals

Refine Journals

Article Types

Refine Types

Countries

Refine Countries
Back to Top