MDPI Contact

MDPI AG
St. Alban-Anlage 66,
4052 Basel, Switzerland
Support contact
Tel. +41 61 683 77 34
Fax: +41 61 302 89 18

For more contact information, see here.

Advanced Search

You can use * to search for partial matches.

Search Results

6 articles matched your search query. Search Parameters:
Authors = Yusuke Tahara

Matches by word:

YUSUKE (108) , TAHARA (14)

View options
order results:
result details:
results per page:
Articles per page View Sort by
Displaying article 1-50 on page 1 of 1.
Export citation of selected articles as:
Open AccessArticle Analysis of a Lipid/Polymer Membrane for Bitterness Sensing with a Preconditioning Process
Sensors 2015, 15(9), 22439-22450; doi:10.3390/s150922439
Received: 31 July 2015 / Revised: 27 August 2015 / Accepted: 31 August 2015 / Published: 4 September 2015
Cited by 2 | Viewed by 872 | PDF Full-text (1102 KB) | HTML Full-text | XML Full-text
Abstract
It is possible to evaluate the taste of foods or medicines using a taste sensor. The taste sensor converts information on taste into an electrical signal using several lipid/polymer membranes. A lipid/polymer membrane for bitterness sensing can evaluate aftertaste after immersion in monosodium
[...] Read more.
It is possible to evaluate the taste of foods or medicines using a taste sensor. The taste sensor converts information on taste into an electrical signal using several lipid/polymer membranes. A lipid/polymer membrane for bitterness sensing can evaluate aftertaste after immersion in monosodium glutamate (MSG), which is called “preconditioning”. However, we have not yet analyzed the change in the surface structure of the membrane as a result of preconditioning. Thus, we analyzed the change in the surface by performing contact angle and surface zeta potential measurements, Fourier transform infrared spectroscopy (FTIR), X-ray photon spectroscopy (XPS) and gas cluster ion beam time-of-flight secondary ion mass spectrometry (GCIB-TOF-SIMS). After preconditioning, the concentrations of MSG and tetradodecylammonium bromide (TDAB), contained in the lipid membrane were found to be higher in the surface region than in the bulk region. The effect of preconditioning was revealed by the above analysis methods. Full article
(This article belongs to the Special Issue Sensors for Food Safety and Quality) Printed Edition available
Open AccessArticle Study of the Relationship between Taste Sensor Response and the Amount of Epigallocatechin Gallate Adsorbed Onto a Lipid-Polymer Membrane
Sensors 2015, 15(3), 6241-6249; doi:10.3390/s150306241
Received: 15 December 2014 / Revised: 19 January 2015 / Accepted: 9 March 2015 / Published: 13 March 2015
Cited by 4 | Viewed by 1294 | PDF Full-text (1387 KB) | HTML Full-text | XML Full-text
Abstract
A taste sensor using lipid-polymer membranes has been developed to evaluate the taste of foods, beverages and medicines. The response of the taste sensor, measured as a change in the membrane potential caused by adsorption (CPA), corresponds to the aftertaste felt by humans.
[...] Read more.
A taste sensor using lipid-polymer membranes has been developed to evaluate the taste of foods, beverages and medicines. The response of the taste sensor, measured as a change in the membrane potential caused by adsorption (CPA), corresponds to the aftertaste felt by humans. The relationships between the CPA value and the amount of adsorbed taste substances, quinine and iso-α acid (bitterness), and tannic acid (astringency), have been studied so far. However, that of epigallocatechin gallate (EGCg) has not been clarified, although EGCg is abundantly present in green tea as one of its astringent substances. This study aimed at clarifying the response of the taste sensor to EGCg and its relationship with the amount of EGCg adsorbed onto lipid-polymer membranes. The lipid concentration dependence of the CPA value was similar to that of the amount of adsorbed EGCg, indicating a high correlation between the CPA value and the amount of adsorbed EGCg. The CPA value increased with increasing amount of adsorbed EGCg; however, the CPA value showed a tendency of leveling off when the amount of adsorbed EGCg further increased. Full article
(This article belongs to the Special Issue State-of-the-Art Sensors Technology in Japan 2015)
Open AccessArticle Relationship between the Amount of Bitter Substances Adsorbed onto Lipid/Polymer Membrane and the Electric Response of Taste Sensors
Sensors 2014, 14(9), 16274-16286; doi:10.3390/s140916274
Received: 3 July 2014 / Revised: 12 August 2014 / Accepted: 26 August 2014 / Published: 2 September 2014
Cited by 10 | Viewed by 1787 | PDF Full-text (2422 KB) | HTML Full-text | XML Full-text
Abstract
The bitterness of bitter substances can be measured by the change in the membrane electric potential caused by adsorption (CPA) using a taste sensor (electronic tongue). In this study, we examined the relationship between the CPA value due to an acidic bitter substance
[...] Read more.
The bitterness of bitter substances can be measured by the change in the membrane electric potential caused by adsorption (CPA) using a taste sensor (electronic tongue). In this study, we examined the relationship between the CPA value due to an acidic bitter substance and the amount of the bitter substance adsorbed onto lipid/polymer membranes, which contain different lipid contents, used in the taste sensor. We used iso-α-acid which is an acidic bitter substance found in several foods and beverages. The amount of adsorbed iso-α-acid, which was determined by spectroscopy, showed a maximum at the lipid concentration 0.1 wt % of the membrane, and the same phenomenon was observed for the CPA value. At the higher lipid concentration, however, the amount adsorbed decreased and then remained constant, while the CPA value decreased monotonically to zero. This constant adsorption amount was observed when the membrane potential in the reference solution did not change with increasing lipid concentration. The decrease in CPA value in spite of the constant adsorption amount is caused by a decrease in the sensitivity of the membrane as the surface charge density increases. The reason why the peaks appeared in both the CPA value and adsorption amount is based on the contradictory adsorption properties of iso-α-acid. The increasing charged lipid concentration of the membrane causes an increasing electrostatic attractive interaction between iso-α-acid and the membrane, but simultaneously causes a decreasing hydrophobic interaction that results in decreasing adsorption of iso-α-acid, which also has hydrophobic properties, onto the membrane. Estimates of the amount of adsorption suggest that iso-α-acid molecules are adsorbed onto both the surface and interior of the membrane. Full article
(This article belongs to the Section Chemical Sensors)
Open AccessArticle Development of a Sweetness Sensor for Aspartame, a Positively Charged High-Potency Sweetener
Sensors 2014, 14(4), 7359-7373; doi:10.3390/s140407359
Received: 12 March 2014 / Revised: 14 April 2014 / Accepted: 21 April 2014 / Published: 23 April 2014
Cited by 12 | Viewed by 2423 | PDF Full-text (415 KB) | HTML Full-text | XML Full-text
Abstract
Taste evaluation technology has been developed by several methods, such as sensory tests, electronic tongues and a taste sensor based on lipid/polymer membranes. In particular, the taste sensor can individually quantify five basic tastes without multivariate analysis. However, it has proven difficult to
[...] Read more.
Taste evaluation technology has been developed by several methods, such as sensory tests, electronic tongues and a taste sensor based on lipid/polymer membranes. In particular, the taste sensor can individually quantify five basic tastes without multivariate analysis. However, it has proven difficult to develop a sweetness sensor, because sweeteners are classified into three types according to the electric charges in an aqueous solution; that is, no charge, negative charge and positive charge. Using membrane potential measurements, the taste-sensing system needs three types of sensor membrane for each electric charge type of sweetener. Since the commercially available sweetness sensor was only intended for uncharged sweeteners, a sweetness sensor for positively charged high-potency sweeteners such as aspartame was developed in this study. Using a lipid and plasticizers, we fabricated various lipid/polymer membranes for the sweetness sensor to identify the suitable components of the sensor membranes. As a result, one of the developed sensors showed responses of more than 20 mV to 10 mM aspartame and less than 5 mV to any other taste. The responses of the sensor depended on the concentration of aspartame. These results suggested that the developed sweetness sensor had high sensitivity to and high selectivity for aspartame. Full article
(This article belongs to the Special Issue Biomimetic Receptors and Sensors)
Open AccessArticle Development of a Portable Taste Sensor with a Lipid/Polymer Membrane
Sensors 2013, 13(1), 1076-1084; doi:10.3390/s130101076
Received: 14 December 2012 / Revised: 14 January 2013 / Accepted: 14 January 2013 / Published: 16 January 2013
Cited by 17 | Viewed by 2557 | PDF Full-text (303 KB) | HTML Full-text | XML Full-text
Abstract
We have developed a new portable taste sensor with a lipid/polymer membrane and conducted experiments to evaluate the sensor’s performance. The fabricated sensor consists of a taste sensor chip (40 mm × 26 mm × 2.2 mm) with working and reference electrodes and
[...] Read more.
We have developed a new portable taste sensor with a lipid/polymer membrane and conducted experiments to evaluate the sensor’s performance. The fabricated sensor consists of a taste sensor chip (40 mm × 26 mm × 2.2 mm) with working and reference electrodes and a portable sensor device (80 mm × 25 mm × 20 mm). The working electrode consists of a taste-sensing site comprising a poly(hydroxyethyl)methacrylate (pHEMA) hydrogel layer with KCl as the electrolyte layer and a lipid/polymer membrane as the taste sensing element. The reference electrode comprises a polyvinyl chloride (PVC) membrane layer with a small hole and a pHEMA layer with KCl. The whole device is the size of a USB memory stick, making it suitable for portable use. The sensor’s response to tannic acid as the standard astringency substance showed good accuracy and reproducibility, and was comparable with the performance of a commercially available taste sensing system. Thus, it is possible for this sensor to be used for in-field evaluations and it can make a significant contribution to the food industry, as well as in various fields of research. Full article
(This article belongs to the Special Issue State-of-the-Art Sensors Technology in Japan 2012)
Figures

Figure 1

Open AccessArticle Development and Evaluation of a Miniaturized Taste Sensor Chip
Sensors 2011, 11(10), 9878-9886; doi:10.3390/s111009878
Received: 22 September 2011 / Revised: 17 October 2011 / Accepted: 18 October 2011 / Published: 20 October 2011
Cited by 14 | Viewed by 2930 | PDF Full-text (847 KB) | HTML Full-text | XML Full-text
Abstract
A miniaturized taste sensor chip was designed for use in a portable-type taste sensing system. The fabricated sensor chip (40 mm × 26 mm × 2.2 mm) has multiple taste-sensing sites consisting of a poly(hydroxyethyl methacrylate) hydrogel with KCl as the electrolyte layer
[...] Read more.
A miniaturized taste sensor chip was designed for use in a portable-type taste sensing system. The fabricated sensor chip (40 mm × 26 mm × 2.2 mm) has multiple taste-sensing sites consisting of a poly(hydroxyethyl methacrylate) hydrogel with KCl as the electrolyte layer for stability of the membrane potential and artificial lipid membranes as the taste sensing elements. The sensor responses to the standard taste substances showed high accuracy and good reproducibility, which is comparable with the performance of the sensor probe of the commercialized taste sensing system. Thus, the fabricated taste sensor chip could be used as a key element for the realization of a portable-type taste sensing system. Full article
(This article belongs to the Special Issue Ultra-Small Sensor Systems and Components)

Years

Subjects

Refine Subjects

Journals

Refine Journals

Article Types

Refine Types

Countries

Refine Countries
Back to Top