MDPI Contact

MDPI AG
St. Alban-Anlage 66,
4052 Basel, Switzerland
Support contact
Tel. +41 61 683 77 34
Fax: +41 61 302 89 18

For more contact information, see here.

Advanced Search

You can use * to search for partial matches.

Search Results

2 articles matched your search query. Search Parameters:
Authors = Veena Choudhary

Matches by word:

VEENA (7) , CHOUDHARY (22)

View options
order results:
result details:
results per page:
Articles per page View Sort by
Displaying article 1-50 on page 1 of 1.
Export citation of selected articles as:
Open AccessFeature PaperArticle vQRS Based on Hybrids of CNT with PMMA-POSS and PS-POSS Copolymers to Reach the Sub-PPM Detection of Ammonia and Formaldehyde at Room Temperature Despite Moisture
Chemosensors 2017, 5(3), 22; doi:10.3390/chemosensors5030022
Received: 11 June 2017 / Revised: 7 July 2017 / Accepted: 10 July 2017 / Published: 12 July 2017
Viewed by 158 | PDF Full-text (3165 KB) | HTML Full-text | XML Full-text
Abstract
Nanocomposite-based quantum resistive vapour sensors (vQRS) have been developed from the assembly of hybrid copolymers of polyhedral oligomeric silsesquioxane (POSS) and poly(methyl methacrylate) (PMMA) or poly(styrene) (PS) with carbon nanotubes (CNT). The originality of the resulting conducting architecture is expected to be responsible
[...] Read more.
Nanocomposite-based quantum resistive vapour sensors (vQRS) have been developed from the assembly of hybrid copolymers of polyhedral oligomeric silsesquioxane (POSS) and poly(methyl methacrylate) (PMMA) or poly(styrene) (PS) with carbon nanotubes (CNT). The originality of the resulting conducting architecture is expected to be responsible for the ability of the transducer to detect sub-ppm concentrations of ammonia and formaldehyde at room temperature despite the presence of humidity. In particular, the boosting effect of POSS is evidenced in CNT-based nanocomposite vQRS. The additive fabrication by spraying layer-by-layer provides (sLbL) is an effective method to control the reproducibility of the transducers’ chemo-resistive responses. In dry atmosphere, the two types of sensors showed a high sensitivity towards both hazardous gases, as they were able to detect 300 ppb of formaldehyde and 500 ppb of ammonia with a sufficiently good signal to noise ratio (SNR > 10). They also exhibited a quick response times less than 5 s for both vapours and, even in the presence of 100 ppm of water, they were able to detect small amounts of gases (1.5 ppm of NH3 and 9 ppm of CH2O). The results suggest promising applications of POSS-based vQRS for air quality or volatolome monitoring. Full article
(This article belongs to the Special Issue Polymers Based Chemical Sensors)
Figures

Figure 1

Open AccessArticle pH- and Metal Ion- Sensitive Hydrogels based on N-[2-(dimethylaminoethyl)acrylamide]
Polymers 2016, 8(6), 233; doi:10.3390/polym8060233
Received: 24 February 2016 / Revised: 12 May 2016 / Accepted: 6 June 2016 / Published: 15 June 2016
Cited by 2 | Viewed by 681 | PDF Full-text (2076 KB) | HTML Full-text | XML Full-text
Abstract
Smart hydrogels are promising materials for actuators and sensors, as they can respond to small changes in their environment with a large property change. Hydrogels can respond to a variety of stimuli, for example temperature, pH, metal ions, etc. In this article,
[...] Read more.
Smart hydrogels are promising materials for actuators and sensors, as they can respond to small changes in their environment with a large property change. Hydrogels can respond to a variety of stimuli, for example temperature, pH, metal ions, etc. In this article, the synthesis and characterization of polyampholyte hydrogels based on open chain ligands showing pH and metal ion sensitivity are described. Copolymer and terpolymer gels using different mixtures of monomers i.e., N-[2-(dimethylaminoethyl)acrylamide] (DMAEAAm), N,N-dimethylacrylamide (DMAAm), acrylic acid (AA) and 2-acrylamido-2-methyl-1-propanesulphonic acid (AMPS), have been synthesized. The effect of copolymer composition, i.e., the ratio and amount of ionic monomers and the degree of crosslinking on the swelling characteristics, was evaluated as a function of pH. On this basis, metal ion sensitivity measurements were performed at selected pH values. The metal ion sensitivity was measured by varying the concentration of Cu2+, Zn2+ and Ag+ ions under acidic pH conditions. Full article
(This article belongs to the Special Issue Polymers for Aqueous Media)
Figures

Years

Subjects

Refine Subjects

Journals

Refine Journals

Article Types

Refine Types

Countries

Refine Countries
Back to Top