MDPI Contact

MDPI AG
St. Alban-Anlage 66,
4052 Basel, Switzerland
Support contact
Tel. +41 61 683 77 34
Fax: +41 61 302 89 18

For more contact information, see here.

Advanced Search

You can use * to search for partial matches.

Search Results

1 article matched your search query. Search Parameters:
Authors = Stanley M. Stevens

Matches by word:

STANLEY (108) , M (17731) , STEVENS (78)

View options
order results:
result details:
results per page:
Articles per page View Sort by
Displaying article 1-50 on page 1 of 1.
Export citation of selected articles as:
Open AccessArticle Direct Analysis in Real Time (DART) of an Organothiophosphate at Ultrahigh Resolution by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry and Tandem Mass Spectrometry
Int. J. Mol. Sci. 2016, 17(1), 116; doi:10.3390/ijms17010116
Received: 29 November 2015 / Revised: 23 December 2015 / Accepted: 8 January 2016 / Published: 16 January 2016
Viewed by 863 | PDF Full-text (1416 KB) | HTML Full-text | XML Full-text
Abstract
Direct analysis in real time (DART) is a recently developed ambient ionization technique for mass spectrometry to enable rapid and sensitive analyses with little or no sample preparation. After swab-based field sampling, the organothiophosphate malathion was analyzed using DART-Fourier transform ion cyclotron resonance
[...] Read more.
Direct analysis in real time (DART) is a recently developed ambient ionization technique for mass spectrometry to enable rapid and sensitive analyses with little or no sample preparation. After swab-based field sampling, the organothiophosphate malathion was analyzed using DART-Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS) and tandem mass spectrometry (MS/MS). Mass resolution was documented to be over 800,000 in full-scan MS mode and over 1,000,000 for an MS/MS product ion produced by collision-induced dissociation of the protonated analyte. Mass measurement accuracy below 1 ppm was obtained for all DART-generated ions that belonged to the test compound in the mass spectra acquired using only external mass calibration. This high mass measurement accuracy, achievable at present only through FTMS, was required for unequivocal identification of the corresponding molecular formulae. Full article
(This article belongs to the Special Issue Fourier Transform Mass Spectrometry in Molecular Sciences)
Figures

Years

Subjects

Refine Subjects

Journals

Refine Journals

Article Types

Refine Types

Countries

Refine Countries
Back to Top