MDPI Contact

MDPI AG
St. Alban-Anlage 66,
4052 Basel, Switzerland
Support contact
Tel. +41 61 683 77 34
Fax: +41 61 302 89 18

For more contact information, see here.

Advanced Search

You can use * to search for partial matches.

Search Results

2 articles matched your search query. Search Parameters:
Authors = Søren Dohn

Matches by word:

SØREN (71) , DOHN (2)

View options
order results:
result details:
results per page:
Articles per page View Sort by
Displaying article 1-50 on page 1 of 1.
Export citation of selected articles as:
Open AccessCommunication Real-Time Particle Mass Spectrometry Based on Resonant Micro Strings
Sensors 2010, 10(9), 8092-8100; doi:10.3390/s100908092
Received: 10 July 2010 / Revised: 30 July 2010 / Accepted: 15 August 2010 / Published: 27 August 2010
Cited by 41 | Viewed by 5709 | PDF Full-text (7620 KB) | HTML Full-text | XML Full-text
Abstract
Micro- and nanomechanical resonators are widely being used as mass sensors due to their unprecedented mass sensitivity. We present a simple closed-form expression which allows a fast and quantitative calculation of the position and mass of individual particles placed on a micro or
[...] Read more.
Micro- and nanomechanical resonators are widely being used as mass sensors due to their unprecedented mass sensitivity. We present a simple closed-form expression which allows a fast and quantitative calculation of the position and mass of individual particles placed on a micro or nano string by measuring the resonant frequency shifts ofthe first two bending modes. The method has been tested by detecting the mass spectrum of micro particles placed on a micro string. This method enables real-time mass spectrometry necessary for applications such as personal monitoring devices for the assessment of theexposure dose of airborne nanoparticles. Full article
(This article belongs to the Section Chemical Sensors)
Open AccessReview SU-8 Cantilevers for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods
Sensors 2008, 8(3), 1595-1612; doi:10.3390/s8031595
Received: 2 November 2007 / Accepted: 3 March 2008 / Published: 10 March 2008
Cited by 80 | Viewed by 8445 | PDF Full-text (659 KB) | HTML Full-text | XML Full-text
Abstract
Here, we present the activities within our research group over the last five yearswith cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interestingpolymer for fabrication of cantilevers for bio/chemical sensing due to its simple processingand low Young’s modulus. We
[...] Read more.
Here, we present the activities within our research group over the last five yearswith cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interestingpolymer for fabrication of cantilevers for bio/chemical sensing due to its simple processingand low Young’s modulus. We show examples of different integrated read-out methodsand their characterisation. We also show that SU-8 cantilevers have a reduced sensitivity tochanges in the environmental temperature and pH of the buffer solution. Moreover, weshow that the SU-8 cantilever surface can be functionalised directly with receptormolecules for analyte detection, thereby avoiding gold-thiol chemistry. Full article

Years

Subjects

Refine Subjects

Journals

Refine Journals

Article Types

Refine Types

Countries

Refine Countries
Back to Top