MDPI Contact

MDPI AG
St. Alban-Anlage 66,
4052 Basel, Switzerland
Support contact
Tel. +41 61 683 77 34
Fax: +41 61 302 89 18

For more contact information, see here.

Advanced Search

You can use * to search for partial matches.

Search Results

10 articles matched your search query. Search Parameters:
Authors = Jindrich Kynicky

Matches by word:

JINDRICH (15) , KYNICKY (10)

View options
order results:
result details:
results per page:
Articles per page View Sort by
Displaying article 1-50 on page 1 of 1.
Export citation of selected articles as:
Open AccessArticle Microwave-Assisted Synthesis of Goethite Nanoparticles Used for Removal of Cr(VI) from Aqueous Solution
Materials 2017, 10(7), 783; doi:10.3390/ma10070783
Received: 31 May 2017 / Revised: 4 July 2017 / Accepted: 4 July 2017 / Published: 11 July 2017
Viewed by 254 | PDF Full-text (4613 KB) | HTML Full-text | XML Full-text
Abstract
The microwave-assisted synthesis of goethite nanoparticles has been studied. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), differential thermal analysis (DTA) and Brunauer–Emmett–Teller (BET) method. Goethite rod-like nanoparticles have been successfully synthesized in 10 min of
[...] Read more.
The microwave-assisted synthesis of goethite nanoparticles has been studied. The samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), differential thermal analysis (DTA) and Brunauer–Emmett–Teller (BET) method. Goethite rod-like nanoparticles have been successfully synthesized in 10 min of microwave treating at 100 °C. Particle size is in the range from 30 to 60 nm in width and from 200 to 350 nm in length. BET analysis indicated that the surface area of the product is 158.31 m2g−1. The feasibility of Cr(VI) removal fromaqueous solution depends on the pH of the solution and contact time. The maximum adsorptionis reached at pH 4.0 and 540 min of contact time. The adsorption kinetics was analyzedby the pseudo-first- and second-order models and the results reveal that the adsorption process obeys the pseudo-second-order model. The adsorption data were fitted well with the Langmuir adsorption isotherm. Full article
(This article belongs to the Special Issue Sorption Materials for Environment Purification)
Figures

Figure 1

Open AccessReview Synthesis and Modification of Clinoptilolite
Molecules 2017, 22(7), 1107; doi:10.3390/molecules22071107
Received: 10 May 2017 / Accepted: 26 June 2017 / Published: 4 July 2017
Viewed by 193 | PDF Full-text (603 KB) | HTML Full-text | XML Full-text
Abstract
Clinoptilolite is a natural mineral with exceptional physical characteristics resulting from its special crystal structure, mainstreamed into a large zeolite group called heulandites. An overall view of the research related to the synthesis, modification and application of synthetic clinoptilolite is presented. A single
[...] Read more.
Clinoptilolite is a natural mineral with exceptional physical characteristics resulting from its special crystal structure, mainstreamed into a large zeolite group called heulandites. An overall view of the research related to the synthesis, modification and application of synthetic clinoptilolite is presented. A single phase of clinoptilolite can be hydrothermally synthesized for 1–10 days in an autoclave from various silica, alumina, and alkali sources with initial Si/Al ratio from 3.0 to 5.0 at a temperature range from 120 to 195 °C. Crystallization rate and crystallinity of clinoptilolite can be improved by seeding. The modification of clinoptilolite has received noticeable attention from the research community, since modified forms have specific properties and therefore their area of application has been broadening. This paper provides a review of the use of organic compounds such as quarter alkyl ammonium, polymer, amine and inorganic species used in the modification process, discusses the processes and mechanisms of clinoptilolite modification, and identifies research gaps and new perspectives. Full article
Figures

Figure 1

Open AccessArticle Study of Linkage between Glutathione Pathway and the Antibiotic Resistance of Escherichia coli from Patients’ Swabs
Int. J. Mol. Sci. 2015, 16(4), 7210-7229; doi:10.3390/ijms16047210
Received: 4 February 2015 / Revised: 13 March 2015 / Accepted: 18 March 2015 / Published: 31 March 2015
Cited by 3 | Viewed by 1322 | PDF Full-text (2796 KB) | HTML Full-text | XML Full-text
Abstract
In this work, we focused on the differences between bacterial cultures of E. coli obtained from swabs of infectious wounds of patients compared to laboratory E. coli. In addition, blocking of the protein responsible for the synthesis of glutathione (γ-glutamylcysteine synthase—GCL) using 10
[...] Read more.
In this work, we focused on the differences between bacterial cultures of E. coli obtained from swabs of infectious wounds of patients compared to laboratory E. coli. In addition, blocking of the protein responsible for the synthesis of glutathione (γ-glutamylcysteine synthase—GCL) using 10 mM buthionine sulfoximine was investigated. Each E. coli showed significant differences in resistance to antibiotics. According to the determined resistance, E. coli were divided into experimental groups based on a statistical evaluation of their properties as more resistant and more sensitive. These groups were also used for finding the differences in a dependence of the glutathione pathway on resistance to antibiotics. More sensitive E. coli showed the same kinetics of glutathione synthesis while blocking GCL (Km 0.1 µM), as compared to non-blocking. In addition, the most frequent mutations in genes of glutathione synthetase, glutathione peroxidase and glutathione reductase were observed in this group compared to laboratory E.coli. The group of “more resistant” E. coli exhibited differences in Km between 0.3 and 0.8 µM. The number of mutations compared to the laboratory E. coli was substantially lower compared to the other group. Full article
(This article belongs to the Section Molecular Pathology, Diagnostics, and Therapeutics)
Figures

Open AccessArticle A 3D Microfluidic Chip for Electrochemical Detection of Hydrolysed Nucleic Bases by a Modified Glassy Carbon Electrode
Sensors 2015, 15(2), 2438-2452; doi:10.3390/s150202438
Received: 22 October 2014 / Revised: 1 December 2014 / Accepted: 4 January 2015 / Published: 22 January 2015
Cited by 6 | Viewed by 1718 | PDF Full-text (2756 KB) | HTML Full-text | XML Full-text | Supplementary Files
Abstract
Modification of carbon materials, especially graphene-based materials, has wide applications in electrochemical detection such as electrochemical lab-on-chip devices. A glassy carbon electrode (GCE) modified with chemically alternated graphene oxide was used as a working electrode (glassy carbon modified by graphene oxide with sulphur
[...] Read more.
Modification of carbon materials, especially graphene-based materials, has wide applications in electrochemical detection such as electrochemical lab-on-chip devices. A glassy carbon electrode (GCE) modified with chemically alternated graphene oxide was used as a working electrode (glassy carbon modified by graphene oxide with sulphur containing compounds and Nafion) for detection of nucleobases in hydrolysed samples (HCl pH = 2.9, 100 °C, 1 h, neutralization by NaOH). It was found out that modification, especially with trithiocyanuric acid, increased the sensitivity of detection in comparison with pure GCE. All processes were finally implemented in a microfluidic chip formed with a 3D printer by fused deposition modelling technology. As a material for chip fabrication, acrylonitrile butadiene styrene was chosen because of its mechanical and chemical stability. The chip contained the one chamber for the hydrolysis of the nucleic acid and another for the electrochemical detection by the modified GCE. This chamber was fabricated to allow for replacement of the GCE. Full article
Open AccessArticle Simultaneous Automatic Electrochemical Detection of Zinc, Cadmium, Copper and Lead Ions in Environmental Samples Using a Thin-Film Mercury Electrode and an Artificial Neural Network
Sensors 2015, 15(1), 592-610; doi:10.3390/s150100592
Received: 23 October 2014 / Accepted: 11 December 2014 / Published: 30 December 2014
Cited by 15 | Viewed by 1829 | PDF Full-text (2579 KB) | HTML Full-text | XML Full-text
Abstract
In this study a device for automatic electrochemical analysis was designed. A three electrodes detection system was attached to a positioning device, which enabled us to move the electrode system from one well to another of a microtitre plate. Disposable carbon tip electrodes
[...] Read more.
In this study a device for automatic electrochemical analysis was designed. A three electrodes detection system was attached to a positioning device, which enabled us to move the electrode system from one well to another of a microtitre plate. Disposable carbon tip electrodes were used for Cd(II), Cu(II) and Pb(II) ion quantification, while Zn(II) did not give signal in this electrode configuration. In order to detect all mentioned heavy metals simultaneously, thin-film mercury electrodes (TFME) were fabricated by electrodeposition of mercury on the surface of carbon tips. In comparison with bare electrodes the TMFEs had lower detection limits and better sensitivity. In addition to pure aqueous heavy metal solutions, the assay was also performed on mineralized rock samples, artificial blood plasma samples and samples of chicken embryo organs treated with cadmium. An artificial neural network was created to evaluate the concentrations of the mentioned heavy metals correctly in mixture samples and an excellent fit was observed (R2 = 0.9933). Full article
Open AccessArticle Effect of Ampicillin, Streptomycin, Penicillin and Tetracycline on Metal Resistant and Non-Resistant Staphylococcus aureus
Int. J. Environ. Res. Public Health 2014, 11(3), 3233-3255; doi:10.3390/ijerph110303233
Received: 7 January 2014 / Revised: 18 February 2014 / Accepted: 24 February 2014 / Published: 19 March 2014
Cited by 10 | Viewed by 2766 | PDF Full-text (664 KB) | HTML Full-text | XML Full-text
Abstract
There is an arising and concerning issue in the field of bacterial resistance, which is confirmed by the number of deaths associated with drug-resistant bacterial infections. The aim of this study was to compare the effects of antibiotics on Staphylococcus aureus non-resistant strain
[...] Read more.
There is an arising and concerning issue in the field of bacterial resistance, which is confirmed by the number of deaths associated with drug-resistant bacterial infections. The aim of this study was to compare the effects of antibiotics on Staphylococcus aureus non-resistant strain and strains resistant to cadmium or lead ions. Metal resistant strains were created by the gradual addition of 2 mM solution of metal ions (cadmium or lead) to the S. aureus culture. An increasing antimicrobial effect of ampicillin, streptomycin, penicillin and tetracycline (0, 10, 25, 50, 75, 150, 225 and 300 µM) on the resistant strains was observed using a method of growth curves. A significant growth inhibition (compared to control) of cadmium resistant cells was observed in the presence of all the four different antibiotics. On the other hand, the addition of streptomycin and ampicillin did not inhibit the growth of lead resistant strain. Other antibiotics were still toxic to the bacterial cells. Significant differences in the morphology of cell walls were indicated by changes in the cell shape. Our data show that the presence of metal ions in the urban environment may contribute to the development of bacterial strain resistance to other substances including antibiotics, which would have an impact on public health. Full article
Open AccessArticle Flow Injection Analysis with Electrochemical Detection for Rapid Identification of Platinum-Based Cytostatics and Platinum Chlorides in Water
Int. J. Environ. Res. Public Health 2014, 11(2), 1715-1724; doi:10.3390/ijerph110201715
Received: 4 December 2013 / Revised: 17 January 2014 / Accepted: 23 January 2014 / Published: 4 February 2014
Viewed by 2873 | PDF Full-text (689 KB) | HTML Full-text | XML Full-text
Abstract
Platinum-based cytostatics, such as cisplatin, carboplatin or oxaliplatin are widely used agents in the treatment of various types of tumors. Large amounts of these drugs are excreted through the urine of patients into wastewaters in unmetabolised forms. This phenomenon leads to increased amounts
[...] Read more.
Platinum-based cytostatics, such as cisplatin, carboplatin or oxaliplatin are widely used agents in the treatment of various types of tumors. Large amounts of these drugs are excreted through the urine of patients into wastewaters in unmetabolised forms. This phenomenon leads to increased amounts of platinum ions in the water environment. The impacts of these pollutants on the water ecosystem are not sufficiently investigated as well as their content in water sources. In order to facilitate the detection of various types of platinum, we have developed a new, rapid, screening flow injection analysis method with electrochemical detection (FIA-ED). Our method, based on monitoring of the changes in electrochemical behavior of analytes, maintained by various pH buffers (Britton-Robinson and phosphate buffer) and potential changes (1,000, 1,100 and 1,200 mV) offers rapid and cheap selective determination of platinum-based cytostatics and platinum chlorides, which can also be present as contaminants in water environments. Full article
Open AccessArticle Behaviour of Zinc Complexes and Zinc Sulphide Nanoparticles Revealed by Using Screen Printed Electrodes and Spectrometry
Sensors 2013, 13(11), 14417-14437; doi:10.3390/s131114417
Received: 1 August 2013 / Revised: 3 September 2013 / Accepted: 8 October 2013 / Published: 25 October 2013
Cited by 6 | Viewed by 2278 | PDF Full-text (2113 KB) | HTML Full-text | XML Full-text
Abstract
In this study, we focused on microfluidic electrochemical analysis of zinc complexes (Zn(phen)(his)Cl2, Zn(his)Cl2) and ZnS quantum dots (QDs) using printed electrodes. This method was chosen due to the simple (easy to use) instrumentation and variable setting of flows.
[...] Read more.
In this study, we focused on microfluidic electrochemical analysis of zinc complexes (Zn(phen)(his)Cl2, Zn(his)Cl2) and ZnS quantum dots (QDs) using printed electrodes. This method was chosen due to the simple (easy to use) instrumentation and variable setting of flows. Reduction signals of zinc under the strictly defined and controlled conditions (pH, temperature, flow rate, accumulation time and applied potential) were studied. We showed that the increasing concentration of the complexes (Zn(phen)(his)Cl2, Zn(his)Cl2) led to a decrease in the electrochemical signal and a significant shift of the potential to more positive values. The most likely explanation of this result is that zinc is strongly bound in the complex and its distribution on the electrode is very limited. Changing the pH from 3.5 to 5.5 resulted in a significant intensification of the Zn(II) reduction signal. The complexes were also characterized by UV/VIS spectrophotometry, chromatography, and ESI-QTOF mass spectrometry. Full article
Open AccessArticle Complexes of Silver(I) Ions and Silver Phosphate Nanoparticles with Hyaluronic Acid and/or Chitosan as Promising Antimicrobial Agents for Vascular Grafts
Int. J. Mol. Sci. 2013, 14(7), 13592-13614; doi:10.3390/ijms140713592
Received: 22 April 2013 / Revised: 3 June 2013 / Accepted: 5 June 2013 / Published: 28 June 2013
Cited by 22 | Viewed by 3049 | PDF Full-text (805 KB) | HTML Full-text | XML Full-text
Abstract
Polymers are currently widely used to replace a variety of natural materials with respect to their favourable physical and chemical properties, and due to their economic advantage. One of the most important branches of application of polymers is the production of different products
[...] Read more.
Polymers are currently widely used to replace a variety of natural materials with respect to their favourable physical and chemical properties, and due to their economic advantage. One of the most important branches of application of polymers is the production of different products for medical use. In this case, it is necessary to face a significant disadvantage of polymer products due to possible and very common colonization of the surface by various microorganisms that can pose a potential danger to the patient. One of the possible solutions is to prepare polymer with antibacterial/antimicrobial properties that is resistant to bacterial colonization. The aim of this study was to contribute to the development of antimicrobial polymeric material ideal for covering vascular implants with subsequent use in transplant surgery. Therefore, the complexes of polymeric substances (hyaluronic acid and chitosan) with silver nitrate or silver phosphate nanoparticles were created, and their effects on gram-positive bacterial culture of Staphylococcus aureus were monitored. Stages of formation of complexes of silver nitrate and silver phosphate nanoparticles with polymeric compounds were characterized using electrochemical and spectrophotometric methods. Furthermore, the antimicrobial activity of complexes was determined using the methods of determination of growth curves and zones of inhibition. The results of this study revealed that the complex of chitosan, with silver phosphate nanoparticles, was the most suitable in order to have an antibacterial effect on bacterial culture of Staphylococcus aureus. Formation of this complex was under way at low concentrations of chitosan. The results of electrochemical determination corresponded with the results of spectrophotometric methods and verified good interaction and formation of the complex. The complex has an outstanding antibacterial effect and this effect was of several orders higher compared to other investigated complexes. Full article
(This article belongs to the Section Biomaterial Sciences)
Open AccessArticle Bio-Sensing of Cadmium(II) Ions Using Staphylococcus aureus
Sensors 2011, 11(11), 10638-10663; doi:10.3390/s111110638
Received: 16 September 2011 / Revised: 31 October 2011 / Accepted: 7 November 2011 / Published: 8 November 2011
Cited by 21 | Viewed by 4340 | PDF Full-text (1053 KB) | HTML Full-text | XML Full-text
Abstract
Cadmium, as a hazardous pollutant commonly present in the living environment, represents an important risk to human health due to its undesirable effects (oxidative stress, changes in activities of many enzymes, interactions with biomolecules including DNA and RNA) and consequent potential risk, making
[...] Read more.
Cadmium, as a hazardous pollutant commonly present in the living environment, represents an important risk to human health due to its undesirable effects (oxidative stress, changes in activities of many enzymes, interactions with biomolecules including DNA and RNA) and consequent potential risk, making its detection very important. New and unique technological and biotechnological approaches for solving this problems are intensely sought. In this study, we used the commonly occurring potential pathogenic microorganism Staphylococcus aureus for the determination of markers which could be used for sensing of cadmium(II) ions. We were focused on monitoring the effects of different cadmium(II) ion concentrations (0, 1.25, 2.5, 5, 10, 15, 25 and 50 µg mL−1) on the growth and energetic metabolism of Staphylococcus aureus. Highly significant changes have been detected in the metabolism of thiol compounds—specifically the protein metallothionein (0.79–26.82 mmol/mg of protein), the enzyme glutathione S-transferase (190–5,827 µmol/min/mg of protein), and sulfhydryl groups (9.6–274.3 µmol cysteine/mg of protein). The ratio of reduced and oxidized glutathione indicated marked oxidative stress. In addition, dramatic changes in urease activity, which is connected with resistance of bacteria, were determined. Further, the effects of cadmium(II) ions on the metabolic pathways of arginine, β-glucosidase, phosphatase, N-acetyl β-D-glucosamine, sucrose, trehalose, mannitol, maltose, lactose, fructose and total proteins were demonstrated. A metabolomic profile of Staphylococcus aureus under cadmium(II) ion treatment conditions was completed seeking data about the possibility of cadmium(II) ion accumulation in cells. The results demonstrate potential in the application of microorganisms as modern biosensor systems based on biological components. Full article
(This article belongs to the Special Issue Sensing of Toxic and Hazardous Metals in Various Environmental Media)

Years

Subjects

Refine Subjects

Journals

Refine Journals

Article Types

Refine Types

Countries

Refine Countries
Back to Top