MDPI Contact

MDPI AG
St. Alban-Anlage 66,
4052 Basel, Switzerland
Support contact
Tel. +41 61 683 77 34
Fax: +41 61 302 89 18

For more contact information, see here.

Search Results

1 article matched your search query. Search Parameters:
Authors = Ignacio Islas Vazquez

Matches by word:

IGNACIO (246) , ISLAS (17) , VAZQUEZ (216)

View options
order results:
result details:
results per page:
Articles per page View Sort by
Displaying article 1-50 on page 1 of 1.
Export citation of selected articles as:
Open AccessOpinion Electronic Devices That Identify Individuals with Fever in Crowded Places: A Prototype
Micromachines 2017, 8(7), 202; doi:10.3390/mi8070202
Received: 1 May 2017 / Revised: 14 June 2017 / Accepted: 16 June 2017 / Published: 24 June 2017
Viewed by 200 | PDF Full-text (1994 KB) | HTML Full-text | XML Full-text | Supplementary Files
Abstract
Most epidemiological surveillance systems for severe infections with epidemic potential are based on accumulated symptomatic cases in defined geographical areas. Eventually, all cases have to be clinically verified to confirm an outbreak. These patients will present high fever at the early stages of
[...] Read more.
Most epidemiological surveillance systems for severe infections with epidemic potential are based on accumulated symptomatic cases in defined geographical areas. Eventually, all cases have to be clinically verified to confirm an outbreak. These patients will present high fever at the early stages of the disease. Here, we introduce a non-invasive low-cost electronic device (bracelet) that measures and reports 24/7, year-round information on the temperature, geographical location, and identification of the subject using the device. The data receiver can be installed in a tower (ground) or a drone (air) in densely populated or remote areas. The prototype was made with low-cost electronic components, and it was tested indoors and outdoors. The prototype shows efficient ground and air connectivity. This electronic device will allow health professionals to monitor the prevalence of fever in a geographical area and to reduce the time span between the presentation of the first cases of a potential outbreak and their medical evaluation by giving an early warning. Field tests of the device, programs, and technical diagrams of the prototype are available as Supplementary Materials. Full article
(This article belongs to the Special Issue Medical Microdevices and Micromachines)
Figures

Figure 1

Years

Subjects

Refine Subjects

Journals

Refine Journals

Article Types

Refine Types

Countries

Refine Countries
Back to Top