A Flexible Pad-Printed Fluxgate Sensor

University of Applied Sciences and Arts Western Switzerland (HES-SO), Geneva, Switzerland
Presented at the Eurosensors 2017 Conference, Paris, France, 3–6 September 2017.
*
Author to whom correspondence should be addressed.
Published: 8 August 2017
Download PDF [1558 KB, uploaded 13 October 2017]

Abstract

A flexible flat micro-Fluxgate sensor with amorphous rectangular core, fabricated using a simple printing technique is presented. All materials were selected to facilitate the fabrication process and to achieve optimal sensor performance. The device’s response to an externally applied magnetic field has been studied. The linear measuring range of the sensor is approximately ±40 μT with a linearity error of <2% FS at 100 kHz excitation frequency, allowing the measurement of the terrestrial magnetic field. Experimental results demonstrate that the behaviour of the fabricated device corresponds to the behaviour of a Fluxgate sensor with high sensitivity.
Keywords: fluxgate sensor; magnetic sensor; magnetometer; pad-printing; flexible fluxgate sensor; magnetic sensor; magnetometer; pad-printing; flexible
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Schoinas, S.; Guamra, A.-M.; Moreillon, F.; Passeraub, P. A Flexible Pad-Printed Fluxgate Sensor. Proceedings 2017, 1, 615.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Proceedings EISSN 2504-3900 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top