Next Article in Journal
Intake Procedures in Colorado Animal Shelters
Previous Article in Journal
Exploration Feeding and Higher Space Allocation Improve Welfare of Growing-Finishing Pigs
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Review

Practices for Alleviating Heat Stress of Dairy Cows in Humid Continental Climates: A Literature Review

by
Sébastien Fournel
*,
Véronique Ouellet
and
Édith Charbonneau
Département des sciences animales, Université Laval, 2425 rue de l’Agriculture, Québec City, QC G1V 0A6, Canada
*
Author to whom correspondence should be addressed.
Animals 2017, 7(5), 37; https://doi.org/10.3390/ani7050037
Submission received: 3 March 2017 / Revised: 24 April 2017 / Accepted: 29 April 2017 / Published: 2 May 2017

Abstract

:

Simple Summary

The severity of heat stress issues on dairy cows will increase as global warming progresses. Fortunately, major advances in environmental management, including fans, misters, sprinklers, and cooled waterbeds, can attenuate the effects of thermal stress on cow health, production, and reproduction. These cooling systems were, however, tested in subtropical areas and their efficiency in northern regions is uncertain. This article assesses the potential of existing technologies to cool cows in humid continental climates through calculation of heat stress indices.

Abstract

Heat stress negatively affects the health and performance of dairy cows, resulting in considerable economic losses for the industry. In future years, climate change will exacerbate these losses by making the climate warmer. Physical modification of the environment is considered to be the primary means of reducing adverse effects of hot weather conditions. At present, to reduce stressful heat exposure and to cool cows, dairy farms rely on shade screens and various forms of forced convection and evaporative cooling that may include fans and misters, feed-line sprinklers, and tunnel- or cross-ventilated buildings. However, these systems have been mainly tested in subtropical areas and thus their efficiency in humid continental climates, such as in the province of Québec, Canada, is unclear. Therefore, this study reviewed the available cooling applications and assessed their potential for northern regions. Thermal stress indices such as the temperature-humidity index (THI) were used to evaluate the different cooling strategies.

1. Introduction

The physiological (e.g., respiration rate) and behavioural (e.g., resting pattern) controls of dairy cows attempt to maintain a constant body temperature by regulating their thermal energy balance, so that heat input through metabolism (maintenance, exercise, growth, lactation, gestation, and feeding) equals heat loss to the environment (by conduction, convection, and evaporation). When environmental conditions exceed a threshold limit that increases the core-body temperature, heat stress sets in and animal welfare can be compromised. Moreover, cow health, production, and reproduction performance are reduced under heat stress [1,2].
Feed intake begins to decline at air temperatures of 25–26 °C in lactating cows [3] as reducing dry matter ingestion is a way to decrease heat production in warm environments [4]. More specifically, the reduction of dry matter intake for heat-stressed cows is about 10 to 15% relative to cooled cows [5]. Cows under heat stress also have elevated respiration and sweating rates, which results in greater body fluid losses that increase maintenance requirements to control dehydration and blood homeostasis [4]. For high-producing cows, Berman et al. [6] found that the respiratory frequency started rising above 50–60 breaths min−1 at ambient temperatures higher than 25 °C. Other studies showed a heat-induced decline in milk yield, which can reach 14% during early lactation and 35% during mid-lactation [7]. Reproduction is affected by high temperature because it reduces the expression of oestrous behaviour, modifies follicular growth, and inhibits embryonic development. As a result of the effects of thermal stress, the dairy industry experiences significant financial losses every year, with annual estimates between $900 and $1500 million in the United States (US) [8].
A broad spectrum of strategies can be used to temper the impact of a hot climate on animal production and dairy profitability, but physical modification of the environment is the primary means. The typical methods can be divided into two groups: (i) those modifying the environment to prevent or limit the degree of heat stress to which cows are exposed; or (ii) those enhancing heat exchange between cows and their environment. Practically, this means increasing the evaporative cooling rate by wetting cows or the air around them (e.g., misters and sprinklers) and increasing convective heat transfer rate by increasing air speed over cows (e.g., fans) [9,10].
Much of the research on cooling systems has been carried out in subtropical regions (e.g., Southern US, Israel, and Saudi Arabia) under conditions of moderate to severe heat stress for durations of several months (typically >30 °C and 40% relative humidity). Although episodic mild to moderate heat stress (typically 25 °C and 75% relative humidity) that occurs under humid continental climates (e.g., Eastern Canada and Northern US) has also been recognised as problematic [11,12], there is limited information available regarding the efficiency of physical applications to abate thermal stress in these conditions. Nevertheless, representative hot environments in both climate zones nearly correspond to the same value (75–77) on a temperature-humidity index (THI) chart [1]. Moreover, in the context of climate change where mean annual temperature is expected to rise by 2–4 °C by 2050 in humid continental areas like the province of Québec (Canada) [13], heat mitigation systems should become more and more popular. Therefore, a better understanding of the potential for cooling options to reduce heat stress on northern dairy farms from a global warming perspective may be relevant.
The evaluation and comparison of the different available practices in this paper are based on thermal stress indices that estimate the impact of ambient conditions around animals on their performance and comfort. The THI has been widely used for this purpose [2,14]. By capturing much of the heat exchange impact of warm environments through temperature and humidity, it often adequately represents the overall effect on livestock [1]. Numerous studies established THI thresholds for heat stress in cattle: comfort (THI < 68), mild discomfort (68 < THI < 72), discomfort (72 < THI < 75), alert (75 < THI < 79), danger (79 < THI < 84), and emergency (THI > 84) [15]. Other indices like the black globe-humidity index (BGHI) and the heat load index (HLI) that add the impact of solar radiation and convective cooling of wind (limitations of the THI) can also be used for certain situations [16]. It is then possible with these indicators to assess the efficiency of cooling systems used under different climates (subtropical versus humid continental).

2. Methods for Reducing Heat Stress

The environmental modifications presented in this section attempt to reduce the potential for heat stress by lowering the solar radiation or temperature around the animal.

2.1. Shading Systems

The first step that should be taken to moderate the stressful effects of a hot climate is to protect cows from direct solar radiation. Shading, either natural or artificial, is one of the most easily implemented and economical methods of minimising heat from solar radiation, but does not alter air temperature nor relative humidity around cows to maximise sensible routes of heat loss [9,17,18].

2.1.1. Shade for Outside Lots

It has been estimated that total heat load in outside lots can be reduced by 30% or more with a well-designed shade [19,20]. Trees can be very effective for providing shade to animals [2,3,9,21,22] as black globe temperature, which integrates effects of net radiation, dry-bulb temperature, and wind speed, measured under two tree shades (29.0–30.2 °C) was significantly lower than that recorded outside the shade (35.5 °C). In addition, rectal temperatures (39.3 and 40.1 °C, respectively) and respiration rates (61 and 79 breaths min−1, respectively) for shaded versus unshaded lactating cows were significantly decreased [23].
Artificial shades (e.g., cloth roof on metal or wood frame with wheels or skids and gable roof structure) have also been used with success since they significantly reduce black globe temperature. Several studies [24,25,26,27,28,29,30,31] reported declines in black globe temperature between 2 and 11 °C under a shade compared with the outside. Consequently, climate differences resulted in variation of thermal stress indicators such as BGHI (4 units) and HLI (13 units) for shaded and unshaded environments (Table 1). The THI values did not differ between both systems since THI does not fully predict heat stress if convective cooling is increased and if solar radiation is reduced under shades [32].
A shaded environment also impacts physiological responses of lactating dairy cows (Table 1). Research works [29,30,33,34] have found an average drop of 0.2 °C of vaginal temperatures between shaded and unshaded cows. Other studies [24,26,35] showed that cows with access to shade had lower rectal temperatures than those without (38.7 and 39.3 °C, respectively). In fact, shade allowed cow rectal temperatures to fall below 39 °C, the level at which heat stress is sufficient to affect milk yield and fertility [3]. Shaded cows generally produce 0.7 kg∙day−1 more milk than unshaded cows [25,26,29,30,36]. The conception rate can be increased by the use of shade, passing from 25.3% in an unshaded situation to 44.4% in a shaded situation [26]. Significant respiration rate decreases (8–36 breaths min−1) were observed for shaded cows during hot summer days [24,26,33,35]. In most cases, shade allowed respiratory frequency to pass under the critical threshold of 60 breaths min−1 [3].

2.1.2. Shade for Dairy Barns

Preventing excess solar heat from entering the building can help to reduce heat load on the animal. The first design criteria to consider should be the orientation of the structure. For example, naturally-ventilated barns with north-to-south orientations have greater solar radiation exposures than barns with east-to-west orientations since sunlight can directly enter both in the morning and afternoon [2]. A trial in California showed an increase in morning (4 breaths min−1) and afternoon (9 breaths min−1) respiration rates of cows when barns were orientated north-to-south versus east-to-west [37]. Otherwise, appropriate window glazing and fixed or seasonal shading options, including overhangs, awnings, and trees, may be used to avoid or reduce the need for cooling [38].

2.2. Roof Insulation

A good thermal insulation of the barn roof is another technique that physically modifies the barn environment and that can limit the adverse effects of high ambient temperature [39]. In warm weather, insulation reduces the flow of heat into the barn and keeps it cooler [10,40]. Indeed, it was found that the addition of insulation beneath the roof of an open shelter reduced dry-bulb temperature and black globe temperature by 1.2 and 2.0 °C, respectively (Table 2). Similarly, THI and BGHI were lessened by 1.3 and 2.2 units, respectively. Consequently, animals in the insulated area consumed more feed (0.2 kg∙day−1) and produced more milk (0.6 kg∙day−1). However, differences were not significant for body temperature and respiration rate [41,42]. A combination of insulated shade and sprinklers was tested by Fuquay et al. [42]. This type of environmental modification improved cow comfort as indicated by lower rectal temperatures (38.7 and 38.8 °C, respectively) and respiration rates (71 and 78 breaths min−1, respectively) compared with a control treatment.

2.3. Air Cooling Systems

2.3.1. Air Conditioning and Zone Cooling

Air conditioning is the most effective option for reducing air temperature and relative humidity. In Arizona, Wiersma and Stott [47] and Stott and Wiersma [48] maintained the conditions inside a refrigerated dairy barn at a THI of 71 and found that fertility was improved. Other studies [49,50,51] reported a significant increase in 4% fat-corrected milk yield in Florida and Louisiana when cows were air-conditioned compared with cows kept outside. In Missouri, Hahn et al. [52] compared an air-conditioned barn with a dry lot under naturally varying conditions. The cooling system, which provided better environmental conditions (Table 3), resulted in an average reduction in rectal temperature (0.4 °C) and a net increase in milk yield (0.5 kg∙cow−1∙day−1). Recently, environmental conditions in an air-conditioned barn and in evaporatively cooled sprinkler and fan and tunnel-ventilated buildings were compared by Bucklin et al. [32]. All cooling methods generally provided conditions more comfortable in the facilities than those outside. However, only the air-conditioned barn maintained the THI consistently below 72 (Table 3).
Zone cooling or inspired-air cooling applies a jet of cooled air onto the head and neck of animals [17,38]. Early studies conducted by Kleiber and Regan [53] and Hahn [54] indicated that cooling the inspired air (19.4–27.8 °C below ambient air) for lactating Holstein cows while they were subjected to a hot environment (32.2–40.5 °C) decreased rectal temperature and respiratory frequency. Similarly, Hahn et al. [55] and Canton et al. [31] found effective reduction of rectal temperature and respiration rate with inspired-air treatments of 8.5–15.5 °C. Roussel and Beatty [56], Fuquay et al. [42], and Gomila et al. [57] also reported significantly lower rectal temperatures and respiration rates for zone-cooled cows. Roussel and Beatty [56] and Gomila et al. [57] reported 7 to 19% increases in milk production for cows provided with inspired-air cooling treatments (Table 4).

2.3.2. Foggers and Misters

Evaporative cooling systems use the energy from the air to evaporate water. The evaporation of water into warm air reduces the air temperature while increasing relative humidity [9,38]. Water can be evaporated from atomizing nozzles (next paragraphs) or cooling pads (Section 2.3.3). The first group includes foggers and misters.
High-pressure (>200 psi) fogging systems integrating a ring of fogging nozzles to circulation fans disperse very fine droplets of water into the surrounding air. As fog droplets are emitted, they are immediately spread into the fan’s air stream where they soon evaporate. Animals are chilled as cooled air is blown over their bodies and as they inspire cooled air [10,22,58,59]. Misting systems generate larger droplets (15 and 50 µm in diameter) than fogging systems, but cool the air by the same principle [9,22,38,58,60].
Bucklin et al. [32] tested a fogging system in a tunnel-ventilated barn in Florida. It also contained feed faced sprinklers that worked only at night when foggers were turned off. The environmental conditions of this building were compared with those outside and in another tunnel barn with only 24 h day−1 sprinklers (Table 5). The THI in the barn with foggers was slightly lower compared with the other treatments, resulting in lower body temperatures of cows. Brouk et al. [61] reported similar results for observations collected in the same two barns during the same time period.
Misting systems were used with good success in the US (Arizona, Kansas, and California) and Saudi Arabia where humidity is typically low [62,63,64,65,66]. Numerous studies [67,68,69,70,71,72,73,74,75] compared the environmental conditions and physiological responses of dairy cows under misters with those obtained under an open-sided barn alone or equipped with fans (Table 6). Globally, ambient temperature in the facilities using misting technologies was 2–9 °C cooler than the barns without evaporative cooling, while relative humidity was increased by 8–50 units of percentage with misters. Overall, misting systems reduced THI by 1 to 5 units [66,67,71,73]. This is in accordance with the formula developed by St-Pierre et al. [8] from published data that quantified similar declines in THI for misting systems used in hot temperatures. Dairy cows generally benefitted from misters since rectal temperatures (−0.8 °C) and respiration rates (−20 breaths min−1) were reduced when used [66,67,68,70,71,72,73,74]. Only Chan et al. [69] observed no significant effect of misters on these parameters. Several research works [68,71,72,73,75] concluded that misting systems positively affects milk yield (+1.7 kg∙day−1).

2.3.3. Evaporative Cooling Pads

Evaporative cooling pads made of fibrous material woven together with large gaps in the grooves are generally added to the air inlets of tunnel-ventilated barns (Section 3.1.3). In this way, the incoming air is pulled through a saturated medium where the conversion of water from a liquid to a vapour phase removes heat energy from the incoming air, which lowers its temperature but increases its relative humidity. Cooling efficiency is about 55–75% for most evaporative cooling pads, but these water-based systems are prone to plugging and algae growth [22,76].
Tunnel-ventilated, water-padded barns reportedly lower room temperature during the hottest part of the day by 2.3–5.6 °C (Table 7). However, because relative humidity is increased (22–27 units of percentage), the impact of combined tunnel ventilation and cooling pads on THI is usually minor (2 units). The installation of wetting pads in a housing facility may reduce core-body temperature (up to 1.0 °C) and respiration rate (2–22 breaths min−1) when compared with open-sided barns without cooling systems or with fans and/or sprinklers [77,78,79,80,81,82]. The effect was slightly different for Shiao et al. [83], with vaginal temperature and respiration rate mostly affected by the sprinkling system. Finally, pads had some or no effect on dry matter intake and milk yield (Table 7).

3. Methods for Enhancing Cow Heat Losses

Increased heat exchange generally involves increasing heat loss from the body surface by enhancing heat loss mechanisms that include conduction (direct contact with a surface), convection (contact with a moving fluid), and evaporation (liquid-to-vapour phase change for water through the respiratory system and skin).

3.1. Air Movement

Air movement is an important factor in the relief of heat stress, as it affects both convective and evaporative heat losses. Additional circulation fans can be installed in the barns if airflow provided by natural or mechanical ventilation is not sufficient [9].

3.1.1. Panel or Basket Fans

Panel or basket fans are usually selected for cooling. Typically, these low volume (235–470 L∙s−1), high speed (1.0–2.5 m∙s−1) fans (LVHS) are 0.6–1.2 m in diameter. They should be spaced at a distance of 10 times their diameter, positioned so they blow air in the direction of the prevailing winds, and tilted downwards to aim their airflow at a point directly below the next fan in line [2,10,84,85].
The addition of LVHS fans to open-sided barns benefitted dairy cows (Table 8). Indeed, ventilated cows had a lower rectal temperature (−0.4 °C) and respiration rate (−11 breaths min−1) and a higher conception rate (+30 units of percentage) compared with control cows. The former also ate more feed (+0.6 kg∙day−1) and produced 1 kg∙day−1 more milk.

3.1.2. Big Ceiling Fans

An alternative to panel or basket fans for hot weather ventilation is high volume, low speed (HVLS) fans. Typically, 2.4–7.5 m diameter ceiling fans are installed 12–18 m apart, along the length of a barn. Fans run at 50 rpm and move 50,000–200,000 L∙s−1 of air [2,10,38,85,88,89].
Bucklin et al. [32] experimented with ceiling fans inside an open-sided barn equipped with sprinklers. The conditions within the building were greatly improved (−4.7 THI units) compared with those outside (Table 9). This result is in accordance with the formula developed by St-Pierre et al. [8] from published data which quantifies similar declines in THI for a system of fans used during periods of heat stress. Worley and Bernard [90] compared air movement patterns, wind speeds, and cow vaginal temperature for HVLS fans with a combination of LVHS fans and misters in a typical dairy free-stall barn. While air speed was more evenly distributed throughout the barn with the HVLS system, the ceiling fans did not provide the desired air speed within the critical areas of the barn. For the extremely hot, humid conditions considered during the experiment, internal temperatures for both groups of cows were above normal, indicating heat stress, but they were higher (0.2 °C) for cows cooled by the HVLS system than for those cooled by circulation fans. Meyer et al. [91] also observed better results in terms of respiration rate (−9 breaths min−1) and milk yield (+3 kgday−1) with LVHS than HVLS fans.

3.1.3. Tunnel Ventilation

Tunnel ventilation is another option that increases airflow to reduce heat stress. With a tunnel ventilation system, large fans (1.2–1.8 m in diameter) are used to move air through a barn at an air speed (1–3 m∙s−1) fast enough to provide a beneficial wind chill effect that cools the cows by convection. The entire air inlet is located on one end wall of the barn with all of the exhaust fans located on the opposite end [2,10,76,92].
Chaiyabutr et al. [78], Smith et al. [80,81], and Shiao et al. [83] investigated the efficacy of using a tunnel-ventilated, water-padded free-stall barn to reduce heat stress in dairy cows (Table 7). Globally, this system improves environmental conditions and the performance of animals compared with open-sided barns alone or with fans and/or sprinklers. Actually, tunnel barns equipped with evaporative cooling pads reduced THI by up to 4.9 units, resulting in decreased rectal temperatures (0.4–1.0 °C) and respiration rates (2–22 breaths min−1) and increased dry matter intake (0.3–2.0 kgday−1) and milk yield (0.3–5.3 kgday−1). Bucklin et al. [32] tested a tunnel barn equipped with sprinklers. The conditions within the building were greatly improved (−5.9 THI units) compared with those outside and slightly better (−0.7 THI unit) relative to an open shed with fans and sprinklers (Table 10).

3.1.4. Low-Profile, Cross-Ventilated Barns

Low-profile, cross-ventilated (LPCV) barns were developed to move air parallel to the body of the cows when they are lying in stalls while traditional tunnel ventilation moves air parallel to the ridge of the building. A ceiling could be used to limit the size of the cross sectional area. However, most often, vertical baffles are used to accelerate the air at cow level to the desired velocity [2,10,84,85,93,94,95]. In fact, baffles can increase air speed to 2.7–3.6 m∙s−1 from 0.9–1.3 m∙s−1 [96].
Smith et al. [82] assessed the effect of evaporative pads on core-body temperature and lying behaviour of lactating Holstein cows housed in LPCV free-stall facilities in a humid environment. They showed that this combination of systems reduced THI by 3.3 units, can decrease vaginal temperature (0.1 °C), and tended to increase lying time.

3.2. Sprinklers

Sprinklers are one of the most common and effective methods to promote heat loss [9]. They generate droplets that wet the cow’s hair coat and skin. Fans force air over the cow’s body, causing evaporative cooling to take place on its surface. Sprinklers use low-pressure nozzles (10–40 psi) with flow rates of about 0.75–2 L∙min−1 run for 1–3 min every 5–15 min in the 21–27 °C temperature range [2,10,22,58,59,85]. However, they are known to generate a large volume of water to be processed [9,59], about 10 times (200–530 and 2050–5350 L∙day−1) that of misting systems [71].
Sprinkling systems have been studied for many decades to establish their effect on cow performance (Table 10). Early works [97,98] established that cows show rapid changes toward normal body temperature and respiration rate when they were removed from sunshine after 2 h, hand-sprinkled with water, and then subjected to a gentle breeze produced by a fan for 1 h. The impact of spray cooling without fans was further assessed on dairy cows maintained under loose-housing conditions [33,42,99,100,101]. Rectal temperatures and respiration rates were either similar or lower for sprinkled cows when compared with those of shaded cows. The addition of a sprinkling system alone had opposing results on daily milk yield since it did not always allow for a production increase. The combination of sprinklers and fans in dairy barns was evaluated in different locations of the US, Argentina, Iran, Israel, and Italy [32,66,70,71,75,102,103,104,105,106,107,108,109,110]. In general, thermal environments were changed with the cooling system since temperature was reduced (0.2–4.9 °C) and relative humidity was increased (0.6–24.4 units of percentage), resulting in decreased THI (0.2–5.9 units). This result is in accordance with the formula developed by St-Pierre et al. [8] from published data which quantified similar declines in THI for sprinkler-fan systems used in hot conditions. Although spraying time differed between the studies (20 s to 30 min), sprinkler and fan cooling resulted in lower body temperatures (0.3–1.1 °C) and respiration rates (7–55 breaths min−1) and improved dry matter intake (0.9–3.0 kgday−1) and milk yield (1.0–4.1 kgday−1cow−1).

3.3. Conductive Cooling

Conductive cooling allows heat transfer from a direct contact between a cow lying down and a cooled surface (bedding, water mattress, or any other water-cooled heat exchanger embedded under the bedding) [111,112]. Little research has been done evaluating the effectiveness of conductive cooling on dairy cows, mainly because they only have 20% of their surface area available to exchange heat via conduction [113].

3.3.1. Bedding

In commercial dairy farms, bedding material is selected based on economic feasibility, cow comfort, cleanliness, and udder health. However, few producers consider the thermal comfort that this bedding material provides. Cummins [114] suggests that the bedding material in a dairy farm should be part of their heat abatement strategies; lower temperatures were reported for limestone (25.9 °C) and sand (26.9 °C) compared with wood shavings (28.6 °C) at 25 mm below the surface. A more recent computational and experimental study showed that sand bedding had higher heat flux for cows when compared with straw and mattresses filled with rubber granules [115]. A study [116] was also conducted to evaluate the use of heat exchangers buried under 25 cm of bedding (sand or dried manure) as components in a conductive system for cooling cows. Sand bedding remained cooler than dried manure bedding in all environments (thermoneutral, hot and dry, and hot and humid) and at all levels of cooling (water on or off).

3.3.2. Water-Cooled Heat Exchangers

Conductive cooling with water-cooled heat exchangers has the advantages of recycling water as a working fluid in a closed-loop system and requiring less energy than evaporative cooling units. This application may also improve animal hygiene and reduce humidity in the barn compared with evaporative cooling systems [112].
The first work involving the use of cooled waterbeds (water-filled compartment between two layers of rubber reinforced with synthetic fabric to add stability) included experimental and modelling parts [117]. The modelling component of the study involved a finite difference model which predicted that cows resting on waterbeds (water cooled at 10 °C) can lose about 20–25% of their metabolic heat (about 1600 W) by conduction. Based on computational fluid dynamics (CFD), Rojano et al. [118] found that a heat exchanger placed under the bedding contributes to 20% of the cooling effect under cool air conditions (18 °C), whereas under hot air conditions (38 °C) the contribution increases to nearly 90%. Subsequently, Mondaca et al. [119] developed a conjugate heat and mass transfer 2-D model which demonstrates that the portion of heat removed by conduction (20%) remains relatively constant at all temperatures when the air is dry and the cow’s skin is fully wetted. However, neither of the last two studies included experimental studies with live animals, and thus the models have not been fully validated. Perano et al. [120] conducted an extensive experimental study exposing animals to hot and humid conditions (THI of 79–81 units) and only half of the cows to cooled water mattresses (4.5 or 10 °C). When cows were conductively cooled with 4.5 °C water, rectal temperature, respiration rate, dry matter intake, and milk yield were respectively improved by 1.0 °C, 18 breaths min−1, 3.1 kg∙day−1, and 2.5 kg∙day−1 compared with control cows (Table 11). Rectal temperature was 0.3 °C lower when cows were cooled with 4.5 °C circulating water versus 10 °C circulating water, but other variables did not show a significant difference between the cooling water temperatures. Ortiz et al. [116] evaluated the effectiveness of conductive cooling of dairy cows with heat exchangers (water at 7 °C) buried under 25 cm of bedding (sand or dried manure). No significant difference in respiratory frequency between the cooled and the uncooled cows was reported, but the core-body temperature was respectively decreased by 0.13 °C and 0.14 °C when sand and dried manure were used as bedding. Recently, Gebremedhin et al. [112] developed a 3-D CFD model establishing that the heat flux for a water mattress at 4.6 °C was 430 W m−2 and dropped to 306 W m−2 for a water temperature of 14.5 °C.

4. Discussion

The available information unmistakably shows that heat stress negatively impacts cow performance, resulting in important economic losses for the dairy industry. The severity of heat stress issues will increase as global warming progresses, especially if genetic selection for growth rate and milk yield continues. Fortunately, major advances in environmental management, including cooling systems, can attenuate the effects of thermal stress on health, production, and reproduction [9]. Although several cooling strategies exist, their efficiency in humid continental climates is still unclear since experiments were mostly conducted under subtropical conditions [17].
The benefits of shades and roof insulation on thermal environment and cow performance through reducing the impact of solar radiation are undeniable no matter the climate zone (Table 1 and Table 2). Even in a temperate humid environment in New Zealand [30], some advantages were recorded on the BGHI value (−2 units) and milk production (+0.4 kg∙day−1) when shade was used. Besides keeping the barn cooler in summer, roof insulation can also reduce the flow of cold air in winter for northern farms [10,40]. Therefore, shading devices at pastures and roof insulation of barns should be used every time it is possible.
Typically, dairy barns in humid continental climates are naturally- or mechanically-ventilated, close-sided facilities. In such cases, air conditioning could be an option and likely the most effective way to reduce and maintain air temperature and relative humidity under an acceptable level where THI < 72 [32]. However, due to energy costs and system maintenance issues (e.g., dust filtration problems for recirculated air, odour-ammonia accumulation), air conditioning (including inspired-air cooling) has been recognised as cost-prohibitive, even in hot climates, and thus air-conditioned barns are uncommon today [17,52,55,61,121].
A combination of fans (to increase convective heat loss) and either sprinklers or foggers/misters (to promote evaporative cooling) has been shown to be the most effective way to cool dairy cows other than using air conditioning [90]. In fact, the addition of fans inside existing buildings to recirculate the air successfully reduced heat stress (Table 12) as shown by decreased body temperatures (−0.5 °C) and respiration rates (−11 breaths min−1), and enhanced milk production (+1.0 kg∙day−1). The levels of improvement of physiological responses by fans alone were near to those reached with evaporative cooling systems (−0.6 °C, −17 breaths min−1, and +2.0 kg∙day−1). Based on data in Table 9, it seems that LVHS fans are more efficient than HVLS fans. For new or remodelled constructions, tunnel-ventilated and LPCV barns (generally equipped with evaporative cooling systems in the reported literature) would also provide a desired chilling effect (Table 12). Nevertheless, the application of LPCV barns may be limited due to the minimum practical size of 400 cows and the few existing guidelines for operating fans during winter in northern countries [96].
High-pressure foggers and misters are known to be especially effective in dry regions in open-sided, ridge-vented, tall barns [2,10,22,58,59]. Therefore, they do not work well in humid environments in close-sided barns because fog or fine mists can cause a more humid microenvironment and inhibit cooling by reducing the vapour pressure potential [89,102,104]. Actually, increasing relative humidity by 10 to 20 units of percentage with the use of foggers or misters (Table 12) when the average summer relative humidity is already 75% in humid continental climates can eradicate any benefit from a potential air temperature drop. In addition, there is some suggestion that the environment produced by these evaporative cooling systems may predispose cows to respiratory disease, especially in enclosed areas [9,22,38,58,60]. Foggers and misters are also particularly prone to clogging and require regular maintenance and control [10,22,58,59,85].
For these reasons, low-pressure sprinklers are more common [122]. In fact, sprinkler-fan systems are among the best strategies to reduce thermal stress (THI decreases of 2.5 units) and to improve dairy cows performance and welfare (−0.5 °C of rectal temperature, −22 breaths min−1, and +2.5 kgday−1 of milk) with only a moderate increase in relative humidity (Table 12). This is why Flamenbaum et al. [102] and Strickland et al. [104] suggest using sprinklers with large droplet sizes as opposed to foggers and misters to achieve effective cooling in humid regions. Moreover, some mechanically-ventilated facilities in humid subtropical climates rely on both evaporative cooling pads to cool the air and low-pressure sprinklers to further cool the cows at the feed-line [122]. Even in high humidity environments created by the evaporative cooling systems, feed-line soaking would provide additional cooling for the cattle [61]. However, based on the results of Shiao et al. [83] in Taiwan, the combination of evaporative cooling, feed-line soaking, and tunnel ventilation did not really change cow physiological responses and increased temperature and THI (Table 7). Therefore, the use of sprinklers and/or evaporative cooling pads could negatively affect environmental conditions in humid continental climates (e.g., pads increase relative humidity by 24 units of percentage; Table 12).
Furthermore, water-based options such as sprinkler-fan systems and evaporative cooling pads may require a significant amount of water and electricity [119] and careful design, operation, and regular maintenance in order to make them work effectively [76]. A direct-contact conductive cooling method that circulates chilled water or low-temperature groundwater in mattresses or heat exchangers may provide a more effective system in terms of energy and water. Indeed, the water, after passing through the system, could be cycled through a refrigeration unit and then reused [112,119]. Such a system enhances heat loss and thereby cools the animal even under hot and humid conditions (Table 11). Additionally, waterbeds can provide benefits such as reduction of lesions, swollen hocks, and cull rates as well as stall cleanliness [123].

5. Conclusions and Implications

The selection of cooling systems to improve cow health and performance without worsening ambient conditions under a humid continental climate can differ from areas that are more arid. Options limiting the flow of heat into the barn or allowing increased convection or conduction should be preferred. In that sense, shade, roof insulation, circulation fans, tunnel ventilation, and water-cooled mattresses are the practical cooling strategies that should be considered under a humid continental climate. All these applications could be implemented on new or remodelled dairy facilities. The installation of evaporative cooling systems such as pads, misters, and sprinklers is not recommended in environments where relative humidity could reach over 75% due to the increase in humidity associated with these systems. The massive need for water resources of evaporative cooling options could also be an issue. Determining practices that will optimize the combination of increased air velocity and conductive cooling in terms of milk yield, reproduction performances, animal health, and resource efficiency in humid continental climates will require more research, especially from a climate change perspective, as global temperature will continue to rise. In this context, while countries with advanced dairy production systems are making many efforts to enhance animal welfare by providing the best environment possible in terms of housing conditions, heat stress is often neglected since it is considered outside of the farmers’ control. On an ethical point of view, the implementation of heat stress control strategies that can improve cow well-being by lessening their body temperature and respiration rate should be as important as the addition of bedding to ensure cow comfort. Thus, future initiatives, programs, or standards developed to meet societal expectations related to animal care, health, welfare as well as environmental stewardship (e.g., proAction in Canada) should include extreme heat mitigation as a key point. The information contained herein should help to point out the best options in humid continental dairy farms.

Acknowledgments

The authors would like to thank Ouranos and the Québec government with its Fonds vert/PACC 2013–2020 initiative for their financial support. The Fonds de recherche du Québec—Nature et technologies is also acknowledged for its funding through a postdoctoral fellowship. The authors also recognise the analysis work done by Andréa L. Bellavance during the project and the English language revision made by Christina McRae from EditWorks.

Author Contributions

Sébastien Fournel conceived the idea for the manuscript and drafted the review paper. Sébastien Fournel and Véronique Ouellet performed the bibliographic research. Édith Charbonneau revised critically different versions of the manuscript and added intellectual content. Véronique Ouellet and Édith Charbonneau reviewed and approved the final version of the manuscript to be published.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. DeShazer, J.A.; Hahn, G.L.; Xin, H. Basic principles of the thermal environment and livestock energetics. In Livestock Energetics and Thermal Environmental Management; DeShazer, J.A., Ed.; American Society of Agricultural and Biological Engineers (ASABE): St. Joseph, MI, USA, 2009; pp. 1–22. [Google Scholar]
  2. Smith, J.F.; Harner, J.P. Strategies to reduce the impact of heat and cold stress in dairy cattle facilities. In Environmental Physiology of Livestock; Collier, R.J., Collier, J.L., Eds.; Wiley-Blackwell: Chichester, UK, 2012; pp. 267–288. [Google Scholar]
  3. Das, R.; Sailo, L.; Verma, N.; Bharti, P.; Saikia, J.; Imtiwati; Kumar, R. Impact of heat stress on health and performance of dairy animals: A review. Vet. World 2016, 9, 260–268. [Google Scholar] [CrossRef] [PubMed]
  4. Kadzere, C.T.; Murphy, M.R.; Silanikove, N.; Maltz, E. Heat stress in lactating dairy cows: A review. Livest. Prod. Sci. 2002, 77, 59–91. [Google Scholar] [CrossRef]
  5. Monteiro, A.P.A.; Tao, S.; Thompson, I.M.; Dahl, G.E. Effect of heat stress during late gestation on immune function and growth performance of calves: Isolation of altered colostral and calf factors. J. Dairy Sci. 2014, 97, 6426–6439. [Google Scholar] [CrossRef] [PubMed]
  6. Berman, A.; Folman, Y.; Kaim, M.; Mamen, M.; Herz, Z.; Wolfenson, D.; Arieli, A.; Graber, Y. Upper critical temperatures and forced ventilation effects for high-yielding dairy cows in a subtropical climate. J. Dairy Sci. 1985, 68, 1488–1495. [Google Scholar] [CrossRef]
  7. Bernabucci, U.; Lacetera, N.; Baumgard, L.H.; Rhoads, R.P.; Ronchi, B.; Nardone, A. Metabolic and hormonal acclimation to heat stress in domesticated ruminants. Animal 2010, 4, 1167–1183. [Google Scholar] [CrossRef] [PubMed]
  8. St-Pierre, N.R.; Cobanov, B.; Schnitkey, G. Economic losses from heat stress by us livestock industries. J. Dairy Sci. 2003, 86, E52–E77. [Google Scholar] [CrossRef]
  9. Renaudeau, D.; Collin, A.; Yahav, S.; de Basilio, V.; Gourdine, J.L.; Collier, R.J. Adaptation to hot climate and strategies to alleviate heat stress in livestock production. Animal 2012, 6, 707–728. [Google Scholar] [CrossRef] [PubMed]
  10. House, H.K. Dairy Housing—Ventilation Options for Free Stall Barns. Available online: http://www.omafra.gov.on.ca/english/engineer/facts/15-017.htm (accessed on 6 May 2016).
  11. Ominski, K.H.; Kennedy, A.D.; Wittenberg, K.M.; Moshtaghi Nia, S.A. Physiological and production responses to feeding schedule in lactating dairy cows exposed to short-term, moderate heat stress. J. Dairy Sci. 2002, 85, 730–737. [Google Scholar] [CrossRef]
  12. Beede, D.K.; Collier, R.J. Potential nutritional strategies for intensively managed cattle during thermal stress. J. Anim. Sci. 1986, 62, 543–554. [Google Scholar] [CrossRef]
  13. OURANOS. Summary of the Synthesis on Climate Change Knowledge in Québec; OURANOS: Montreal, QC, Canada, 2015; pp. 1–13. [Google Scholar]
  14. Collier, R.J.; Dahl, G.E.; VanBaale, M.J. Major advances associated with environmental effects on dairy cattle. J. Dairy Sci. 2006, 89, 1244–1253. [Google Scholar] [CrossRef]
  15. Segnalini, M.; Bernabucci, U.; Vitali, A.; Nardone, A.; Lacetera, N. Temperature humidity index scenarios in the mediterranean basin. Int. J. Biometeorol. 2013, 57, 451–458. [Google Scholar] [CrossRef] [PubMed]
  16. Gaughan, J.B.; Mader, T.L.; Gebremedhin, K.G. Rethinking heat index tools for livestock. In Environmental Physiology of Livestock; Collier, R.J., Collier, J.L., Eds.; John Wiley & Sons, Inc.: Chichester, UK, 2012; pp. 243–265. [Google Scholar]
  17. West, J.W. Effects of heat-stress on production in dairy cattle. J. Dairy Sci. 2003, 86, 2131–2144. [Google Scholar] [CrossRef]
  18. Pennington, J.A.; VanDevender, K. Heat Stress in Dairy Cattle. Available online: http://articles.extension.org/pages/11047/heat-stress-in-dairy-cattle (accessed on 18 May 2016).
  19. Bond, T.E.; Kelly, C.E. The globe thermometer in agricultural research. Agric. Eng. 1955, 36, 251–255. [Google Scholar]
  20. Blackshaw, J.K.; Blackshaw, A.W. Heat-stress in cattle and the effect of shade on production and behavior. Aust. J. Exp. Agric. 1994, 34, 285–295. [Google Scholar] [CrossRef]
  21. Armstrong, D.V. Heat stress interaction with shade and cooling. J. Dairy Sci. 1994, 77, 2044–2050. [Google Scholar] [CrossRef]
  22. Shearer, J.K.; Bray, R.A.; Bucklin, R.A. The Management of Heat Stress in Dairy Cattle: What We Have Learned in Florida. In Proc. Feed and Nutrional Management Cow College; Virginia Tech: Manassas, VA, USA, 1999. [Google Scholar]
  23. Valtorta, S.E.; Leva, P.E.; Gallardo, M.R. Evaluation of different shades to improve dairy cattle well-being in Argentina. Int. J. Biometeorol. 1997, 41, 65–67. [Google Scholar] [CrossRef] [PubMed]
  24. Collier, R.J.; Eley, R.M.; Sharma, A.K.; Pereira, R.M.; Buffington, D.E. Shade management in subtropical environment for milk yield and composition in Holstein and Jersey cows. J. Dairy Sci. 1981, 64, 844–849. [Google Scholar] [CrossRef]
  25. Muller, C.J.C.; Botha, J.A.; Smith, W.A. Effect of shade on various parameters of Friesian cows in a Mediterranean climate in South Africa. 1. Feed and water intake, milk production and milk composition. S. Afr. J. Anim. Sci. 1994, 24, 49–55. [Google Scholar]
  26. Roman-Ponce, H.; Thatcher, W.W.; Buffington, D.E.; Wilcox, C.J.; Van Horn, H.H. Physiological and production responses of dairy cattle to a shade structure in a subtropical environment. J. Dairy Sci. 1977, 60, 424–430. [Google Scholar] [CrossRef]
  27. Schütz, K.E.; Rogers, A.R.; Cox, N.R.; Tucker, C.B. Dairy cows prefer shade that offers greater protection against solar radiation in summer: Shade use, behaviour, and body temperature. Appl. Anim. Behav. Sci. 2009, 116, 28–34. [Google Scholar] [CrossRef]
  28. Schütz, K.E.; Rogers, A.R.; Cox, N.R.; Webster, J.R.; Tucker, C.B. Dairy cattle prefer shade over sprinklers: Effects on behavior and physiology. J. Dairy Sci. 2011, 94, 273–283. [Google Scholar] [CrossRef] [PubMed]
  29. Schütz, K.E.; Rogers, A.R.; Poulouin, Y.A.; Cox, N.R.; Tucker, C.B. The amount of shade influences the behavior and physiology of dairy cattle. J. Dairy Sci. 2010, 93, 125–133. [Google Scholar] [CrossRef] [PubMed]
  30. Fisher, A.D.; Roberts, N.; Bluett, S.J.; Verkerk, G.A.; Matthews, L.R. Effects of shade provision on the behaviour, body temperature and milk production of grazing dairy cows during a New Zealand summer. N. Z. J. Agric. Res. 2008, 51, 99–105. [Google Scholar] [CrossRef]
  31. Canton, G.H.; Buffington, D.E.; Collier, R.J. Inspired-air cooling for dairy cows. Trans. ASAE 1982, 25, 730–734. [Google Scholar] [CrossRef]
  32. Bucklin, R.A.; Bray, D.R.; Martin, J.G.; Carlos, L.; Carvalho, V. Environmental temperatures in Florida dairy housing. Appl. Eng. Agric. 2009, 25, 727–735. [Google Scholar] [CrossRef]
  33. Kendall, P.E.; Verkerk, G.A.; Webster, J.R.; Tucker, C.B. Sprinklers and shade cool cows and reduce insect-avoidance behavior in pasture-based dairy systems. J. Dairy Sci. 2007, 90, 3671–3680. [Google Scholar] [CrossRef] [PubMed]
  34. Tucker, C.B.; Rogers, A.R.; Schütz, K.E. Effect of solar radiation on dairy cattle behaviour, use of shade and body temperature in a pasture-based system. Appl. Anim. Behav. Sci. 2008, 109, 141–154. [Google Scholar] [CrossRef]
  35. Muller, C.J.C.; Botha, J.A.; Coetzer, W.A.; Smith, W.A. Effect of shade on various parameters of Friesian cows in a Mediterranean climate in South Africa. 2. Physiological responses. S. Afr. J. Anim. Sci. 1994, 24, 56–60. [Google Scholar]
  36. Kendall, P.E.; Nielsen, P.P.; Webster, J.R.; Verkerk, G.A.; Littlejohn, R.P.; Matthews, L.R. The effects of providing shade to lactating dairy cows in a temperate climate. Livest. Sci. 2006, 103, 148–157. [Google Scholar] [CrossRef]
  37. Smith, J.F.; Brouk, M.J.; Harner, J.P. Influence of Freestall Building Orientation on Comfort of Lactating Dairy Cattle during Summer Heat Stress; Kansas State University: Manhattan, KS, USA, 2001. [Google Scholar]
  38. Aggarwal, A.; Upadhyay, R. Shelter management for alleviation of heat stress in cows and buffaloes. In Heat Stress and Animal Productivity; Aggarwal, A., Upadhyay, R., Eds.; Springer: New Delhi, India, 2013; pp. 169–183. [Google Scholar]
  39. Calegari, F.; Calamari, L.; Frazzi, E. Misting and fan cooling of the rest area in a dairy barn. Int. J. Biometeorol. 2012, 56, 287–295. [Google Scholar] [CrossRef] [PubMed]
  40. Menconi, M.E.; Grohmann, D. Model integrated of life-cycle costing and dynamic thermal simulation (mild) to evaluate roof insulation materials for existing livestock buildings. Energy Build. 2014, 81, 48–58. [Google Scholar] [CrossRef]
  41. Daniel, J.W.; Fuquay, J.W.; Brown, W.H.; Cardwell, J.T. Roof insulation in a freestall barn for lactating cows during the summer. J. Dairy Sci. 1973, 56, 303–316. [Google Scholar]
  42. Fuquay, J.W.; Zook, A.B.; Daniel, J.W.; Brown, W.H.; Poe, W.E. Modifications in freestall housing for dairy cows during the summer. J. Dairy Sci. 1979, 62, 577–583. [Google Scholar] [CrossRef]
  43. Lawrence, M.G. The relationship between relative humidity and the dewpoint temperature in moist air: A simple conversion and applications. Bull. Am. Meteorol. Soc. 2005, 86, 225–233. [Google Scholar] [CrossRef]
  44. Schüller, L.K.; Burfeind, O.; Heuwieser, W. Impact of heat stress on conception rate of dairy cows in the moderate climate considering different temperature–humidity index thresholds, periods relative to breeding, and heat load indices. Theriogenology 2014, 81, 1050–1057. [Google Scholar] [CrossRef] [PubMed]
  45. Buffington, D.E.; Collazo-Arocho, A.; Canton, G.H.; Pitt, D.; Thatcher, W.W.; Collier, R.J. Black globe-humidity index (bghi) as comfort equation for dairy cows. Trans. ASAE 1981, 24, 711–714. [Google Scholar] [CrossRef]
  46. Gaughan, J.B.; Mader, T.L.; Holt, S.M.; Lisle, A. A new heat load index for feedlot cattle. J. Anim. Sci. 2008, 86, 226. [Google Scholar] [CrossRef] [PubMed]
  47. Wiersma, F.; Stott, G.H. Microclimate modification for hot weather stress relief of dairy cattle. Trans. ASAE 1966, 9, 309–313. [Google Scholar]
  48. Stott, G.H.; Wiersma, F. Short term thermal relief for improved fertility in dairy cattle during hot weather. Int. J. Biometeorol. 1976, 20, 344–350. [Google Scholar] [CrossRef] [PubMed]
  49. Johnson, J.E.; Stone, E.J.; Frye, J.B., Jr. Effects of Hot Weather on the Productive Function of Dairy Cows; Louisiana Agricultural Experiment Station Bulletin: Baton Rouge, LA, USA, 1966. [Google Scholar]
  50. Thatcher, W.W. Effects of season, climate, and temperature on reproduction and lactation. J. Dairy Sci. 1974, 57, 360–368. [Google Scholar] [CrossRef]
  51. Thatcher, W.W.; Gwazdauskas, F.C.; Wilcox, C.J.; Toms, J.; Head, H.H.; Buffington, D.E.; Fredricksson, W.B. Milking performance and reproductive efficiency of dairy cows in an environmentally controlled structure. J. Dairy Sci. 1974, 57, 304–307. [Google Scholar] [CrossRef]
  52. Hahn, G.L.; Sikes, J.D.; Shanklin, M.D.; Johnson, H.D. Dairy cow responses to summer air-conditioning as evaluated by switchback experimental design. Trans. ASAE 1969, 13, 289–291. [Google Scholar]
  53. Kleiber, M.; Regan, W. Influence of temperature on respiration of cows. Proc. Soc. Exp. Biol. Med. 1935, 33, 10–14. [Google Scholar] [CrossRef]
  54. Hahn, G.L. Cooling Inspired-Air for Dairy Cattle; USDA-ARS: Columbia, MO, USA, 1962.
  55. Hahn, G.L.; Johnson, H.D.; Shanklin, M.D.; Kibler, H.H. Inspired-air cooling for lactating dairy cows in a hot environment. Trans. ASAE 1965, 8, 332–337. [Google Scholar] [CrossRef]
  56. Roussel, J.D.; Beatty, J.F. Influence of zone cooling on performance of cows lactating during stressful summer conditions. J. Dairy Sci. 1970, 53, 1085–1088. [Google Scholar] [CrossRef]
  57. Gomila, L.F.; Roussel, J.D.; Beatty, J.F. Effect of zone cooling on milk yield, thyroid activity and stress indicators. J. Dairy Sci. 1977, 60, 129–132. [Google Scholar] [CrossRef]
  58. Jones, G.M.; Stallings, C.C. Reducing Heat Stress for Dairy Cattle; Virginia Cooperative Extension: Blacksburg, VA, USA, 1999; pp. 1–6. [Google Scholar]
  59. Worley, J.W. Cooling Systems for Georgia Dairy Cattle; The University of Georgia, College of Agricultural and Environmental Sciences: Athens, GE, USA, 1999; pp. 1–8. [Google Scholar]
  60. Bucklin, R.A.; Turner, L.W.; Beede, D.K.; Bray, D.R.; Hemken, R.W. Methods to relieve heat stress for dairy cows in hot, humid environments. Appl. Eng. Agric. 1991, 7, 241–247. [Google Scholar] [CrossRef]
  61. Brouk, M.J.; Armstrong, D.; Smith, J.; VanBaale, M.; Bray, D.; Harner, J., III. Evaluating and Selecting Cooling Systems for Different Climates. Available online: http://articles.extension.org/pages/17586/evaluating-and-selecting-cooling-systems-for-different-climates (accessed on 31 May 2016).
  62. Anderson, S.D.; Bradford, B.J.; Harner, J.P.; Tucker, C.B.; Choi, C.Y.; Allen, J.D.; Hall, L.W.; Rungruang, S.; Collier, R.J.; Smith, J.F. Effects of adjustable and stationary fans with misters on core body temperature and lying behavior of lactating dairy cows in a semiarid climate. J. Dairy Sci. 2013, 96, 4738–4750. [Google Scholar] [CrossRef] [PubMed]
  63. Ortiz, X.A.; Smith, J.F.; Villar, F.; Hall, L.; Allen, J.; Oddy, A.; al-Haddad, A.; Lyle, P.; Collier, R.J. A comparison of 2 evaporative cooling systems on a commercial dairy farm in Saudi Arabia. J. Dairy Sci. 2015, 98, 8710–8722. [Google Scholar] [CrossRef] [PubMed]
  64. Ryan, D.P.; Boland, M.P.; Kopel, E.; Armstrong, D.; Munyakazi, L.; Godke, R.A.; Ingraham, R.H. Evaluating two different evaporative cooling management systems for dairy cows in a hot, dry climate. J. Dairy Sci. 1992, 75, 1052–1059. [Google Scholar] [CrossRef]
  65. Schultz, T.A.; Morrison, S.R. Manger misting improves dairy cows’ appetite. Calif. Agric. 1987, 41, 12–13. [Google Scholar]
  66. Brouk, M.J.; Harner, J.P.; Smith, J.F.; Hammond, A.K.; Miller, W.F.; Park, A.F. Effect of soaking and misting on respiration rate, body surface temperature, and body temperature of heat stress dairy cattle. In KSU Dairy Day Report of Progress; Kansas State University: Manhattan, KS, USA, 2003; Volume 919. [Google Scholar]
  67. Boonsanit, D.; Chanpongsang, S.; Chaiyabutr, N. Effects of supplemental recombinant bovine somatotropin and mist-fan cooling on the renal tubular handling of sodium in different stages of lactation in crossbred Holstein cattle. Res. Vet. Sci. 2012, 93, 417–426. [Google Scholar] [CrossRef] [PubMed]
  68. Calegari, F.; Calamari, L.; Frazzi, E. Cooling systems of the resting area in free stall dairy barn. Int. J. Biometeorol. 2016, 60, 605–614. [Google Scholar] [CrossRef] [PubMed]
  69. Chan, S.C.; Huber, J.T.; Chen, K.H.; Simas, J.M.; Wu, Z. Effects of ruminally inert fat and evaporative cooling on dairy cows in hot environmental temperatures. J. Dairy Sci. 1997, 80, 1172–1178. [Google Scholar] [CrossRef]
  70. Correa-Calderon, A.; Armstrong, D.; Ray, D.; DeNise, S.; Enns, M.; Howison, C. Thermoregulatory responses of Holstein and Brown Swiss heat-stressed dairy cows to two different cooling systems. Int. J. Biometeorol. 2004, 48, 142–148. [Google Scholar] [PubMed]
  71. Lin, J.C.; Moss, B.R.; Koon, J.L.; Flood, C.A.; Smith, R.C., III; Cummins, K.A.; Coleman, D.A. Comparison of various fan, sprinkler, and mister systems in reducing heat stress in dairy cows. Appl. Eng. Agric. 1998, 14, 177–182. [Google Scholar] [CrossRef]
  72. Takamitsu, A.; Takahashi, S.; Kurihara, M.; Kume, S. Effect of an evaporative cooling procedure on the physiological responses of lactating dairy cows in a hot, humid climate. Jpn. J. Zootech. Sci. 1987, 58, 790–796. [Google Scholar]
  73. Tarazón-Herrera, M.; Huber, J.T.; Santos, J.; Mena, H.; Nusso, L.; Nussio, C. Effects of bovine somatotropin and evaporative cooling plus shade on lactation performance of cows during summer heat stress. J. Dairy Sci. 1999, 82, 2352–2357. [Google Scholar] [CrossRef]
  74. Frazzi, E.; Calamari, L.; Calegari, F.; Stefanini, L. Behavior of dairy cows in response to different barn cooling systems. Trans. ASAE 2000, 43, 387–394. [Google Scholar] [CrossRef]
  75. Frazzi, E.; Calamari, L.; Calegari, F. Productive response of dairy cows to different barn cooling systems. Trans. ASAE 2002, 45, 395–405. [Google Scholar] [CrossRef]
  76. Ward, D. Tunnel Ventilation in Livestock Barns—With and Without Evaporative Cooling. Available online: http://www.omafra.gov.on.ca/english/engineer/facts/13-073.htm (accessed on 6 May 2016).
  77. Brown, W.H.; Fuquay, J.W.; McGee, W.H.; Iyengar, S.S. Evaporative cooling for Mississippi dairy cows. Trans. ASAE 1974, 17, 513–515. [Google Scholar] [CrossRef]
  78. Chaiyabutr, N.; Chanpongsang, S.; Suadsong, S. Effects of evaporative cooling on the regulation of body water and milk production in crossbred Holstein cattle in a tropical environment. Int. J. Biometeorol. 2008, 52, 575–585. [Google Scholar] [CrossRef] [PubMed]
  79. Chen, K.H.; Huber, J.T.; Theurer, C.B.; Armstrong, D.V.; Wanderley, R.C.; Simas, J.M.; Chan, S.C.; Sullivan, J.L. Effect of protein quality and evaporative cooling on lactational performance of Holstein cows in hot weather. J. Dairy Sci. 1993, 76, 819–825. [Google Scholar] [CrossRef]
  80. Smith, T.R.; Chapa, A.; Willard, S.; Herndon, C., Jr.; Williams, R.J.; Crouch, J.; Riley, T.; Pogue, D. Evaporative tunnel cooling of dairy cows in the Southeast. II: Impact on lactation performance. J. Dairy Sci. 2006, 89, 3915–3923. [Google Scholar] [CrossRef]
  81. Smith, T.R.; Chapa, A.; Willard, S.; Herndon, C., Jr.; Williams, R.J.; Crouch, J.; Riley, T.; Pogue, D. Evaporative tunnel cooling of dairy cows in the Southeast. I: Effect on body temperature and respiration rate. J. Dairy Sci. 2006, 89, 3904–3914. [Google Scholar] [CrossRef]
  82. Smith, J.F.; Bradford, B.J.; Harner, J.P.; Potts, J.C.; Allen, J.D.; Overton, M.W.; Ortiz, X.A.; Collier, R.J. Short communication: Effect of cross ventilation with or without evaporative pads on core body temperature and resting time of lactating cows. J. Dairy Sci. 2016, 99, 1495–1500. [Google Scholar] [CrossRef] [PubMed]
  83. Shiao, T.F.; Chen, J.C.; Yang, D.W.; Lee, S.N.; Lee, C.F.; Cheng, W.T.K. Feasibility assessment of a tunnel-ventilated, water-padded barn on alleviation of heat stress for lactating holstein cows in a humid area. J. Dairy Sci. 2011, 94, 5393–5404. [Google Scholar] [CrossRef] [PubMed]
  84. Atkins, I.; Choi, C.; Holmes, B. Dairy Cooling in Humid Continental Climates. Available online: http://www.schaeferventilation.com/media/1703/dairy-cooling-in-humid-continental-climates_2816.pdf (accessed on 3 March 2017).
  85. Holmes, B.; Cook, N.B.; Funk, T.; Graves, R.; Kammel, D.W.; Reinemann, D.J.; Zulovich, J.M. Dairy Freestall Housing and Equipment, 8th ed.; MidWest Plan Service: Ames, IA, USA, 2013. [Google Scholar]
  86. Folman, Y.; Berman, A.; Herz, Z.; Kaim, M.; Rosenberg, M.; Mamen, M.; Gordin, S. Milk yield and fertility of high-yielding dairy cows in a sub-tropical climate during summer and winter. J. Dairy Res. 1979, 46, 411–425. [Google Scholar] [CrossRef]
  87. Calegari, F.; Calamari, L.; Frazzi, E. Fan cooling of the resting area in a free stalls dairy barn. Int. J. Biometeorol. 2014, 58, 1225–1236. [Google Scholar] [CrossRef] [PubMed]
  88. Kammel, D.W.; Raabe, M.E.; Kappelman, J.J. Design of high volume low speed fan supplemental cooling system in dairy freestall barns. In Proceedings of the Fifth International Dairy Housing Conference (ASAE), Fort Worth, TX, USA, 29–31 January 2003; pp. 243–254. [Google Scholar]
  89. Kuczynski, T.; Blanes-Vidal, V.; Li, B.M.; Gates, R.S.; Nääs, I.A.; Moura, D.J.; Berckmans, D.; Banhazi, T.M. Impact of global climate change on the health, welfare and productivity of intensively housed livestock. Int. J. Agric. Biol. Eng. 2011, 4, 1–22. [Google Scholar]
  90. Worley, J.W.; Bernard, J.K. Comparison of high volume low speed (HVLS) vs. conventional fans in a free stall dairy in a hot humid climate. In Proceedings of the 2006 ASABE Annual International Meeting, Portland, OR, USA, 9–12 July 2006. [Google Scholar]
  91. Meyer, M.J.; Smith, J.F.; Harner, J.P.; Shirley, J.E.; Titgemeyer, E.C.; Brouk, M.J. Performance of lactating dairy cattle in three different cooling systems. Appl. Eng. Agric. 2002, 18, 341–345. [Google Scholar] [CrossRef]
  92. Naud, D.; Leblanc, R.; Dubreuil, L. La Ventilation Longitudinale dans Les étables Laitières. Available online: https://www.agrireseau.net/banqueplans/feuillets/feuillet%2020913.pdf (accessed on 6 May 2016).
  93. Díaz-Royón, F.; Endres, M.I.; García, A.D. Cross-Ventilated Barns for Dairy Cows: New Building Design with Cow Comfort in Mind. Available online: http://articles.extension.org/pages/68439/cross-ventilated-barns-for-dairy-cows:-new-building-design-with-cow-comfort-in-mind (accessed on 30 June 2016).
  94. Lobeck, K.M.; Endres, M.I.; Shane, E.M.; Godden, S.M.; Fetrow, J. Animal welfare in cross-ventilated, compost-bedded pack, and naturally ventilated dairy barns in the upper Midwest. J. Dairy Sci. 2011, 94, 5469–5479. [Google Scholar] [CrossRef] [PubMed]
  95. Smith, J.F.; Harner, J.P. Comprehensive Evaluation of a Low-Profile Cross-Ventilated Free Stall Barn. Available online: http://articles.extension.org/pages/11046/comprehensive-evaluation-of-a-low-profile-cross-ventilated-free-stall-barn (accessed on 15 July 2016).
  96. House, H.K. Low Profile Cross Ventilation Barns. Available online: http://www.omafra.gov.on.ca/english/livestock/dairy/facts/lpbarns.htm (accessed on 26 July 2016).
  97. Seath, D.M.; Miller, G.D. Effects of shade and sprinkling with water on summer comfort of Jersey cows. J. Dairy Sci. 1947, 30, 255–261. [Google Scholar] [CrossRef]
  98. Seath, D.M.; Miller, G.D. Effect of water sprinkling with and without air movement on cooling dairy cows. J. Dairy Sci. 1948, 31, 361–366. [Google Scholar] [CrossRef]
  99. Igono, M.O.; Steevens, B.J.; Shanklin, M.D.; Johnson, H.D. Spray cooling effects on milk production, milk, and rectal temperatures of cows during a moderate temperate summer season. J. Dairy Sci. 1985, 68, 979–985. [Google Scholar] [CrossRef]
  100. Chen, J.M.; Schütz, K.E.; Tucker, C.B. Cooling cows efficiently with water spray: Behavioral, physiological, and production responses to sprinklers at the feed bunk. J. Dairy Sci. 2016, 99, 4607–4618. [Google Scholar] [CrossRef] [PubMed]
  101. Chen, J.M.; Schütz, K.E.; Tucker, C.B. Cooling cows efficiently with sprinklers: Physiological responses to water spray. J. Dairy Sci. 2015, 98, 6925–6938. [Google Scholar] [CrossRef] [PubMed]
  102. Flamenbaum, I.; Wolfenson, D.; Mamen, M.; Berman, A. Cooling dairy cattle by a combination of sprinkling and forced ventilation and its implementation in the shelter system. J. Dairy Sci. 1986, 69, 3140–3147. [Google Scholar] [CrossRef]
  103. Igono, M.O.; Johnson, H.D.; Steevens, B.J.; Krause, G.F.; Shanklin, M.D. Physiological, productive, and economic benefits of shade, spray, and fan system versus shade for Holstein cows during summer heat. J. Dairy Sci. 1987, 70, 1069–1079. [Google Scholar] [CrossRef]
  104. Strickland, J.T.; Bucklin, R.A.; Nordstedt, R.A.; Beede, D.K.; Bray, D.R. Sprinkler and fan cooling system for dairy cows in hot, humid climates. Appl. Eng. Agric. 1989, 5, 231–236. [Google Scholar] [CrossRef]
  105. Her, E.; Wolfenson, D.; Flamenbaum, I.; Folman, Y.; Kaim, M.; Berman, A. Thermal, productive, and reproductive responses of high yielding cows exposed to short-term cooling in summer. J. Dairy Sci. 1988, 71, 1085–1092. [Google Scholar] [CrossRef]
  106. Valtorta, S.E.; Gallardo, M.R. Evaporative cooling for Holstein dairy cows under grazing conditions. Int. J. Biometeorol. 2004, 48, 213–217. [Google Scholar] [CrossRef] [PubMed]
  107. Keister, Z.O.; Moss, K.D.; Zhang, H.M.; Teegerstrom, T.; Edling, R.A.; Collier, R.J.; Ax, R.L. Physiological responses in thermal stressed Jersey cows subjected to different management strategies. J. Dairy Sci. 2002, 85, 3217–3224. [Google Scholar] [CrossRef]
  108. Karimi, M.T.; Ghorbani, G.R.; Kargar, S.; Drackley, J.K. Late-gestation heat stress abatement on performance and behavior of Holstein dairy cows. J. Dairy Sci. 2015, 98, 6865–6875. [Google Scholar] [CrossRef] [PubMed]
  109. Hillman, P.E.; Gebremedhin, K.G.; Parkhurst, A.; Fuquay, J.W.; Willard, S. Evaporative and Convective Cooling of Cows in a Hot and Humid Environment. In Proceedings of the Livestock Environment VI, Louisville, KY, USA, 21–23 May 2001; Stowell, R., Bucklin, R., Botcher, R.W., Eds.; American Society of Agricultural Engineers (ASAE): Louisville, KY, USA, 2001. [Google Scholar]
  110. Turner, L.W.; Chastain, J.P.; Hemken, R.W.; Gates, R.S.; Crist, W.L. Reducing heat stress in dairy cows through sprinkler and fan cooling. Appl. Eng. Agric. 1992, 8, 251–256. [Google Scholar] [CrossRef]
  111. Hansen, P.J.; Dikmen, S.; Sakatani, M.; Dahl, G.E. Cooling Strategies during Heat Stress. Available online: http://articles.extension.org/pages/63354/cooling-strategies-during-heat-stress (accessed on 5 May 2016).
  112. Gebremedhin, K.G.; Wu, B.; Perano, K. Modeling conductive cooling for thermally stressed dairy cows. J. Therm. Biol. 2016, 56, 91–99. [Google Scholar] [CrossRef] [PubMed]
  113. Collier, R.J.; Hall, L.W.; Ortiz, X.A. Facility Modifications to Reduce Heat Stress; USDA National Institute of Food and Agriculture: Okeechobee, FL, USA, 2013; pp. 12–23.
  114. Cummins, K. Bedding plays role in heat abatement. Dairy Herd Manag. 1998, 35, 20. [Google Scholar]
  115. Radoń, J.; Bieda, W.; Lendelová, J.; Pogran, Š. Computational model of heat exchange between dairy cow and bedding. Comput. Electron. Agric. 2014, 107, 29–37. [Google Scholar] [CrossRef]
  116. Ortiz, X.A.; Smith, J.F.; Rojano, F.; Choi, C.Y.; Bruer, J.; Steele, T.; Schuring, N.; Allen, J.; Collier, R.J. Evaluation of conductive cooling of lactating dairy cows under controlled environmental conditions. J. Dairy Sci. 2015, 98, 1759–1771. [Google Scholar] [CrossRef] [PubMed]
  117. Bastian, K.R.; Gebremedhin, K.G.; Scott, N.R. Finite difference model to determine conduction heat loss to a water-filled mattress for dairy cows. Trans. ASAE 2003, 46, 773–780. [Google Scholar] [CrossRef]
  118. Rojano, F.; Mondaca, M.; Choi, C.Y. Feasibility of a dual cooling system for dairy cows in Arizona. In Proceedings of the 2011 ASABE Annual International Meeting (ASABE), Louisville, KY, USA, 7–10 August 2011. [Google Scholar]
  119. Mondaca, M.; Rojano, F.; Choi, C.Y.; Gebremedhin, K.G. A conjugate heat and mass transfer model to evaluate the efficiency of conductive cooling for dairy cattle. Trans. ASAE 2013, 56, 1471–1482. [Google Scholar]
  120. Perano, K.M.; Usack, J.G.; Angenent, L.T.; Gebremedhin, K.G. Production and physiological responses of heat-stressed lactating dairy cattle to conductive cooling. J. Dairy Sci. 2015, 98, 5252–5261. [Google Scholar] [CrossRef] [PubMed]
  121. Chiappini, U.; Christiaens, J.P.A. Cooling in animal houses. In 2nd Report of Working Group on Climatization of Animal Houses; CIGR, IWONL, Eds.; Centre for Climatization of Animal Houses—Advisory Services, Faculty of Agricultural Sciences, State University of Ghent: Gent, Belgium, 1992; pp. 82–97. [Google Scholar]
  122. Atkins, I.; Choi, C.; Bucklin, R.A. Dairy Cooling in Humid Subtropical Climates. Available online: http://www.progressivedairy.com/topics/barns-equipment/dairy-cooling-in-humid-subtropical-climates (accessed on 9 June 2016).
  123. Fulwider, W.K.; Grandin, T.; Garrick, D.J.; Engle, T.E.; Lamm, W.D.; Dalsted, N.L.; Rollin, B.E. Influence of free-stall base on tarsal joint lesions and hygiene in dairy cows. J. Dairy Sci. 2007, 90, 3559–3566. [Google Scholar] [CrossRef] [PubMed]
Table 1. Meteorological and thermal stress attributes and physiological response for non-shaded (NS) and shaded (S) environments.
Table 1. Meteorological and thermal stress attributes and physiological response for non-shaded (NS) and shaded (S) environments.
ReferenceLocationBreedSystemTdbRH 1Tdp 2WSTbgTHI 3BGHI 4HLI 5BT 6RRMY
(°C)(%)(°C)(m∙s−1)(°C)(°C)(Breaths min−1)(kg∙day−1)
Collier et al. [24]Florida, USHolstein, JerseyNS 39.6115
S 38.779
Muller et al. [25]South AfricaFriesianNS 19.0
S 20.1
Roman-Ponce et al. [26]Florida, USHolstein, Jersey, Guernsey, Brown SwissNS28782423779879639.48215.0
S28792422879788338.95416.6
Schütz et al. [27]New ZealandHolstein-FriesianNS2058111124657062
S206413 226668
Schütz et al. [28]New ZealandHolstein-FriesianNS274213729737574
S254914 267172
Schütz et al. [29]New ZealandHolstein-FriesianNS22591463069767838.56218.8
S236115 246971 38.45418.4
Fisher et al. [30]New ZealandHolstein-FriesianNS188014 216368 39.0 13.9
S197715 196466 38.9 14.3
Kendall et al. [33]New ZealandHolstein-FriesianNS 38.97813.2
S 38.65414.0
Tucker et al. [34]New ZealandHolstein-FriesianNS 37.9
S 37.7
Muller et al. [35]South AfricaFriesianNS 38.978
S 38.664
Kendall et al. [36]New ZealandHolstein-FriesianNS 38.9 17.2
S 38.6 17.7
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, Tdp = dew-point temperature, WS = wind speed, Tbg = black globe temperature, THI = temperature-humidity index, BGHI = black globe-humidity index, HLI = heat load index, BT = body temperature, RR = respiration rate, MY = milk yield; 1 Calculated from Lawrence [43] if not given by the authors: RH = 100 × EXP[−5419(Tdb − Tdp)/(Tdb + 273.15)/(Tdp + 273.15)]; 2 Calculated from Lawrence [43] if not given by the authors: Tdp = Tdb − [((100 − RH)/5)((Tdb + 273.15)/300)2] − 0.00135(RH − 84)2 + 0.35; 3 Calculated from Schüller et al. [44] if not given by the authors: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)]; 4 Calculated from Buffington et al. [45]: BGHI = Tbg + 0.36Tdp + 41.5; 5 Calculated from Gaughan et al. [46] if not given by the authors: HLI = IF[Tbg > 25, 8.62 + (0.38RH)(1.55 Tbg) + EXP(2.4 − WS) − 0.5WS, 10.66 + (0.28RH) + (1.3Tbg) − WS]; 6 Body temperature refers to rectal temperature for studies in Florida and South Africa and to vaginal temperature for studies in New Zealand.
Table 2. Meteorological and thermal stress attributes and physiological response of dairy cows for non-insulated (NI) and insulated (I) shades.
Table 2. Meteorological and thermal stress attributes and physiological response of dairy cows for non-insulated (NI) and insulated (I) shades.
ReferenceLocationSystemTdbRHTdp 1TbgTHI 2BGHI 3DMIMY
(°C)(%)(°C)(°C)(kg∙day−1)(kg∙day−1)
Daniel et al. [41]Mississippi, USNI 18.217.9
I 18.418.9
Fuquay et al. [42]Mississippi, USNI31.756.422.032.881.682.2 24.1
I30.558.221.430.880.380.0 24.3
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, Tdp = dew-point temperature, Tbg = black globe temperature, THI = temperature-humidity index, BGHI = black globe-humidity index, DMI = dry matter intake, MY = milk yield; 1 Calculated from Lawrence [43]: Tdp = Tdb − [((100 − RH)/5)((Tdb + 273.15)/300)2] − 0.00135(RH − 84)2 + 0.35; 2 Calculated from Schüller et al. [44]: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)]; 3 Calculated from Buffington et al. [45]: BGHI = Tbg + 0.36Tdp + 41.5.
Table 3. Meteorological attributes and THI calculations for control treatments and air-conditioned dairy barns.
Table 3. Meteorological attributes and THI calculations for control treatments and air-conditioned dairy barns.
ReferenceLocationBreedSystemTdbRHTHI 1
(°C)(%)
Bucklin et al. [32]Florida, USHolsteinOutside27.770.077.9
Air-conditioned barn22.085.070.5
Hahn et al. [52]—Year 1Missouri, USHolsteinDry lot25.966.974.9
Air-conditioned barn23.465.271.0
Hahn et al. [52]—Year 2Missouri, USHolsteinDry lot23.473.871.8
Air-conditioned barn23.267.070.9
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, THI = temperature-humidity index; 1 Calculated from Schüller et al. [44]: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)].
Table 4. Meteorological attributes, THI calculations, and physiological response of dairy cows in shaded environments (S) with or without zone cooling systems (ZC).
Table 4. Meteorological attributes, THI calculations, and physiological response of dairy cows in shaded environments (S) with or without zone cooling systems (ZC).
ReferenceLocationBreedSystemTdbRHTHI 1RTRRMY
(°C)(%)(°C)(Breaths min−1)(kg∙day−1)
Canton et al. [31]Florida, USHolstein-FriesianS 38.977
S + ZC 38.662
Fuquay et al. [42]—Year 1Mississippi, USUnknownS31.756.481.6
S + ZC26.971.176.9
Fuquay et al. [42]—Year 2Mississippi, USUnknownS29.854.578.738.878
S + ZC26.565.275.538.771
Roussel and Beatty [56]Louisiana, USHolstein, Jersey, GuernseyS 40.08717.3
S + ZC 39.48220.6
Gomila et al. [57]Louisiana, USHolstein, GuernseyS 39.17719.7
S + ZC 38.96421.0
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, THI = temperature-humidity index, RT = rectal temperature, RR = respiration rate, MY = milk yield; 1 Calculated from Schüller et al. [44]: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)].
Table 5. Meteorological attributes and THI calculations between different housing systems for dairy cows in the study of Bucklin et al. [32].
Table 5. Meteorological attributes and THI calculations between different housing systems for dairy cows in the study of Bucklin et al. [32].
SystemTdbRHTHI 1
(°C)(%)
Outside27.58479.4
Tunnel barn with low-pressure feed faced sprinklers27.88980.6
Tunnel barn with high-pressure foggers and low-pressure feed faced sprinklers25.79978.1
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, THI = temperature-humidity index; 1 Calculated from Schüller et al. [44]: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)].
Table 6. Meteorological attributes, THI calculations, and physiological response of dairy cows for control treatments and barns equipped with mist-fan systems.
Table 6. Meteorological attributes, THI calculations, and physiological response of dairy cows for control treatments and barns equipped with mist-fan systems.
ReferenceLocationBreedSystem 1TdbRHTHI 2BT 3RRDMIMY
(°C)(%)(°C)(Breaths min−1)(kg∙day−1)(kg∙day−1)
Brouk et al. [66] Kansas, USHolsteinUB33.336.080.040.2115
UB + M + F24.785.574.839.167
Boonsanit et al. [67]ThailandCrossbred HolsteinOB31.070.182.839.470
OB + M + F29.278.481.438.958
Calegari et al. [68]ItalyFriesianOB + F 60 29.8
OB + M + F 56 30.8
Correa-Calderon et al. [70]Arizona, USHolsteinS 39.787
S + M + F 38.850
Correa-Calderon et al. [70]Arizona, USBrown SwissS 39.279
S + M + F 38.852
Lin et al. [71]—Year 1Alabama, USHolsteinOB + F27.968.378.0 6617.122.4
OB + M + F25.981.076.5 5718.523.0
Lin et al. [71]—Year 2Alabama, USHolsteinOB + F31.569.583.6 7717.521.0
OB + M + F26.688.578.5 6619.624.2
Takamitsu et al. [72]—Test 1JapanHolsteinOB 40.1698.718.4
OB + M + F 39.3539.420.3
Takamitsu et al. [72]—Test 2JapanHolsteinOB 39.8698.518.5
OB + M + F 38.8549.119.6
Tarazón-Herrera et al. [73]Arizona, USHolsteinS38.026.183.239.58423.427.7
S + M + F32.336.678.938.76723.429.0
Frazzi et al. [74]ItalyFriesianOB 39.594 29.0
OB + M + F 38.670 29.4
Frazzi et al. [75]ItalyFriesianOB 21.830.6
OB + M + F 22.134.8
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, THI = temperature-humidity index, BT = body temperature, RR = respiration rate, DMI = dry matter intake, MY = milk yield; 1 Housing system components: UB = unknown type of barn, M = mister, F = circulation fan, OB = open-sided barn, S = shade; 2 Calculated from Schüller et al. [44] if not given by the authors: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)]; 3 Body temperature refers to rectal temperature for all studies except for Brouk et al. [66] and Takamitsu et al. [72] (first experimental test) who used vaginal temperature.
Table 7. Meteorological attributes, THI calculations, and physiological response of dairy cows for control treatments and barns equipped with evaporative cooling pads.
Table 7. Meteorological attributes, THI calculations, and physiological response of dairy cows for control treatments and barns equipped with evaporative cooling pads.
ReferenceLocationBreedSystem 1TdbRHTHI 2BT 3RRDMIMY
(°C)(%)(°C)(Breaths min−1)(kg∙day−1)(kg∙day−1)
Brown et al. [77]—Year 1Mississippi, USUnknownOB + F 40.195 18.9
OB + P 39.891 20.5
Brown et al. [77]—Year 2Mississippi, USUnknownOB + F 39.178 24.9
OB + P 39.074 25.4
Brown et al. [77]—Year 3Mississippi, USUnknownOB + F 38.965 22.5
OB + P 38.864 21.4
Chaiyabutr et al. [78]ThailandCrossbred HolsteinOB33.46184.839.786 10.8
TVB + P27.88479.938.764 16.1
Chen et al. [79]Arizona, USHolsteinS 39.182 27.5
S + P 38.664 30.0
Smith et al. [80,81]—Year 1Mississippi, USHolsteinOB + K + F33.164.485.039.06814.822.5
TVB + P30.191.184.838.65516.525.1
Smith et al. [80,81]—Year 2Mississippi, USHolsteinOB + F24.971.373.839.37114.226.7
TVB + P22.693.572.238.75516.229.5
Smith et al. [82]Minnesota, USHolsteinO25.464.373.8
CVB25.462.773.738.7
CVB + P21.986.070.438.6
Shiao et al. [83]TaiwanHolsteinOB + K + F30.975.783.738.95418.524.7
TVB + P27.199.980.839.15218.825.0
TVB + P + K27.798.881.738.95618.825.4
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, THI = temperature-humidity index, BT = body temperature, RR = respiration rate, DMI = dry matter intake, MY = milk yield; 1 Housing system components: OB = open-sided barn, F = circulation fan, P = evaporative cooling pad, S = shade, K = sprinkler, TVB = tunnel-ventilated barn, O = outside, CVB = cross-ventilated barn; 2 Calculated from Schüller et al. [44]: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)]; 3 Body temperature refers to rectal [78,79,80,81] or vaginal [82,83] temperature. In one case [77], BT location was unknown.
Table 8. Physiological response of dairy cows for control treatments and barns equipped with high-speed fans.
Table 8. Physiological response of dairy cows for control treatments and barns equipped with high-speed fans.
ReferenceLocationBreedSystem 1BT 2RRCRDMIMY
(°C)(Breaths min−1)(%)(kg∙day−1)(kg∙day−1)
Berman et al. [6]IsraelHolsteinS 73
S + F 59
Takamitsu et al. [72] JapanHolsteinOB40.169 8.718.4
OB + F39.659 9.319.4
Frazzi et al. [74]ItalyFriesianOB39.594 29.0
OB + F38.978 29.6
Folman et al. [86]IsraelFriesianOB39.8 22 34.3
OB + F39.3 52 36.2
Calegari et al. [87]ItalyFriesianOB + K38.856 32.1
OB + K+ F38.754 32.4
Abbreviations: BT = body temperature, RR = respiration rate, CR = conception rate, DMI = dry matter intake, MY = milk yield; 1 Housing system components: S = shade, F = circulation fan, OB = open-sided barn, K = sprinkler; 2 Body temperature refers to rectal temperature for all studies except for Takamitsu et al. [72] who used vaginal temperature.
Table 9. Meteorological attributes, THI calculations, and physiological response of dairy cows for control treatments and barns equipped with ceiling fans.
Table 9. Meteorological attributes, THI calculations, and physiological response of dairy cows for control treatments and barns equipped with ceiling fans.
ReferenceLocationBreedSystem 1TdbRHTHI 2VTRRMY
(°C)(%)(°C)(Breaths min−1)(kg∙day−1)
Bucklin et al. [32]Florida, USHolsteinO33.950.083.4
OB + K + CF29.755.078.7
Worley and Bernard [90]Georgia, USHolsteinOB + M + F 39.3
OB + CF 39.5
Meyer et al. [91]Kansas, USHolsteinOB + K + F 7540.1
OB + K + CF 8437.1
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, THI = temperature-humidity index, VT = vaginal temperature, RR = respiration rate, MY = milk yield; 1 Housing system components: O = outside, OB = open-sided barn, K = sprinkler, CF = ceiling fan, M = mister, F = circulation fan; 2 Calculated from Schüller et al. [44]: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)].
Table 10. Meteorological attributes, THI calculations, and physiological response of dairy cows for control treatments and barns equipped with sprinklers.
Table 10. Meteorological attributes, THI calculations, and physiological response of dairy cows for control treatments and barns equipped with sprinklers.
ReferenceLocationBreedSystem 1TdbRH THI 2BT 3RR DMIMY
(°C)(%)(°C)(Breaths min−1)(kg∙day−1)(kg∙day−1)
Bucklin et al. [32]Florida, USHolsteinO33.95083.8
OB + K + F29.75578.6
TVB + K29.05677.9
Kendall et al. [33]New ZealandHolstein-FriesianS 38.654 14.0
S + K 38.624 13.6
Fuquay et al. [42]Mississippi, USUnknownS30.560.180.638.984
S + K29.764.080.038.882
Brouk et al. [66] Kansas, USHolsteinUB 40.2115
UB + K + F 39.160
Correa-Calderon et al. [70]Arizona, USHolsteinS 39.787
S + K + F 39.064
Correa-Calderon et al. [70]Arizona, USBrown SwissS 39.279
S + K + F 38.961
Lin et al. [71]—Year 1Alabama, USHolsteinOB + F27.968.378.0 6617.122.4
OB + K + F25.584.376.2 5419.025.0
Lin et al. [71]—Year 2Alabama, USHolsteinOB + F31.569.583.6 7717.521.0
OB + K + F27.593.980.7 5820.524.0
Frazzi et al. [75]ItalyItalian FriesianOB 21.830.6
OB + K + F 22.733.5
Seath and Miller [97]Louisiana, USJerseyO 39.383
S 38.858
S + K 38.741
Seath and Miller [98]Louisiana, USJerseyO 39.7109
CB 39.388
CB + K 39.077
CB + F 38.972
CB + K + F 38.774
Igono et al. [99]Missouri, USHolsteinS 39.1 23.2
S + K 38.8 23.9
Chen et al. [100]California, USHolstein-FriesianOB 38.9 42.6
OB + K 38.6 46.1
Flamenbaum et al. [102]IsraelHolsteinOB 38.9
OB + K + F 38.2
Igono et al. [103]Missouri, USHolsteinS31.043.078.539.2 32.8 423.3
S + K + F30.843.678.338.8 35.1 425.3
Strickland et al. [104]Florida, USHolsteinOB 9517.818.1
OB + K + F 5719.120.2
Her et al. [105]IsraelHolsteinOB 39.2
OB + K + F 38.6
Valtorta and Gallardo [106]ArgentinaHolsteinS 39.572 22.1
S + K + F 39.254 23.2
Keister et al. [107]—Year 1Arizona, USJerseyS 21.8
S + K + F 23.1
Keister et al. [107]—Year 2Arizona, USJerseyS32.840.380.2 102 20.5
S + K + F29.159.378.5 80 22.4
Karimi et al. [108]IranHolsteinOB 39.57013.740.5
OB + K + F 39.26315.544.6
Hillman et al. [109]New York, USHolsteinUB 40.090
UB + K + F 39.374
Turner et al. [110]Kentucky, USHolsteinOB 39.29134.9 422.7
OB + K + F 38.77538.1 426.3
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, THI = temperature-humidity index, BT = body temperature, RR = respiration rate, DMI = dry matter intake, MY = milk yield; 1 Housing system components: O = outside, OB = open-sided barn, K = sprinkler, F = circulation fan, TVB = tunnel-ventilated barn, S = shade, UB = unknown type of barn, CB = close-sided barn; 2 Calculated from Schüller et al. [44]: THI = (1.8Tdb + 32) − [(0.55 − 0.0055RH)(1.8Tdb − 26)]; 3 Body temperature refers to rectal temperature in all studies except those of Kendall et al. [33], Brouk et al. [66], and Chen et al. [100], which used vaginal temperature; 4 Feed intake (kg∙day−1, as fed).
Table 11. Physiological response of dairy cows for a barn equipped with waterbeds at different water temperatures.
Table 11. Physiological response of dairy cows for a barn equipped with waterbeds at different water temperatures.
ReferenceLocationBreedSystemRTRRDMIMY
(°C)(Breaths min−1)(kg∙day−1)(kg∙day−1)
Perano et al. [120]New York, USHolsteinUncooled40.18218.930.3
Cooled at 10 °C39.46820.932.6
Cooled at 4.5 °C39.16422.032.8
Abbreviations: RT = rectal temperature, RR = respiration rate, DMI = dry matter intake, MY = milk yield.
Table 12. Average improvements of potential cooling systems for humid continental farms on meteorological and thermal stress attributes and physiological response of dairy cows.
Table 12. Average improvements of potential cooling systems for humid continental farms on meteorological and thermal stress attributes and physiological response of dairy cows.
MethodCooling SystemTdbTbgRHTHIBGHIHLIRTVTRRCRFIDMIMY
(°C)(°C)(%)(°C)(°C)(Breaths min−1)(%)(kg∙day−1)(kg∙day−1)(kg∙day−1)
Modifying the environment to limit the degree of heat stressShade0.0−4.4 0.0−4.2−13.0−0.6−0.2−22 +0.7
Roof insulation−1.2−2.0 −1.3−2.2 +0.2+0.6
Evaporative cooling pad−3.5 +23.7−2.4 −0.60.0−10 +1.3+1.9
Fogger−2.1 +10.0−2.5
Mister-fan−4.6 +20.0−3.5 −0.8−1.0−20 +0.9+1.7
Enhancing heat exchange between cows and their environmentSprinkler−0.8 +3.9−0.6 −0.2−0.1−16 +1.3
Sprinkler-fan−2.8 +11.1−2.5 −0.5−1.1−22 +2.8+1.8+2.5
Tunnel ventilation (+pad)−3.5 +23.8−2.2 −0.70.0−12 +1.3+2.9
Cross ventilation (+pad)−3.5 +21.7−3.4
LVHS −0.4−0.5−11+30 +0.6+1.0
HVLS (+sprinkler)−4.2 +5.0−4.7
Waterbeds −0.9 −16 +2.6+2.4
Abbreviations: Tdb = dry-bulb temperature, RH = relative humidity, Tbg = black globe temperature, THI = temperature-humidity index, BGHI = black globe-humidity index, HLI = heat load index, RT = rectal temperature, VT = vaginal temperature, RR = respiration rate, CR = conception rate, FI = feed intake, DMI = dry matter intake, MY = milk yield, LVHS = low volume, high speed fans, HVLS = high volume, low speed fans.

Share and Cite

MDPI and ACS Style

Fournel, S.; Ouellet, V.; Charbonneau, É. Practices for Alleviating Heat Stress of Dairy Cows in Humid Continental Climates: A Literature Review. Animals 2017, 7, 37. https://doi.org/10.3390/ani7050037

AMA Style

Fournel S, Ouellet V, Charbonneau É. Practices for Alleviating Heat Stress of Dairy Cows in Humid Continental Climates: A Literature Review. Animals. 2017; 7(5):37. https://doi.org/10.3390/ani7050037

Chicago/Turabian Style

Fournel, Sébastien, Véronique Ouellet, and Édith Charbonneau. 2017. "Practices for Alleviating Heat Stress of Dairy Cows in Humid Continental Climates: A Literature Review" Animals 7, no. 5: 37. https://doi.org/10.3390/ani7050037

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop