<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="en" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="publisher-id">buildings</journal-id>
      <journal-title>Buildings</journal-title>
      <abbrev-journal-title abbrev-type="publisher">Buildings</abbrev-journal-title>
      <abbrev-journal-title abbrev-type="pubmed">Buildings</abbrev-journal-title>
      <issn pub-type="epub">2075-5309</issn>
      <publisher>
        <publisher-name>MDPI</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.3390/buildings2040519</article-id>
      <article-id pub-id-type="publisher-id">buildings-02-00519</article-id>
      <article-categories>
        <subj-group>
          <subject>Article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Systematic Study of the Failure of a Light-Frame Wood Roof in a Tornado</article-title>
      </title-group>
      
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>van de Lindt</surname>
            <given-names>John</given-names>
          </name>
          <xref rid="af1-buildings-02-00519" ref-type="aff">1</xref>
          <xref rid="c1-buildings-02-00519" ref-type="corresp">*</xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Amini</surname>
            <given-names>Mohammad Omar</given-names>
          </name>
          <xref rid="af1-buildings-02-00519" ref-type="aff">1</xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Standohar-Alfano</surname>
            <given-names>Christine</given-names>
          </name>
          <xref rid="af2-buildings-02-00519" ref-type="aff">2</xref>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Dao</surname>
            <given-names>Thang</given-names>
          </name>
          <xref rid="af2-buildings-02-00519" ref-type="aff">2</xref>
        </contrib>
      </contrib-group>
      <aff id="af1-buildings-02-00519"><label>1 </label>Department of Civil and Environmental Engineering, Colorado State University, Fort Collins, CO 80523, USA; E-Mail: <email>omar.amini@rams.colostate.edu</email></aff>
      <aff id="af2-buildings-02-00519"><label>2 </label>Department of Civil, Construction, and Environmental Engineering, University of Alabama, Tuscaloosa, AL 35487, USA; E-Mails: <email>calfano@crimson.ua.edu</email> (C.S.-A.); <email>tndao@eng.ua.edu</email> (T.D.)</aff>
	  <author-notes>
        <corresp id="c1-buildings-02-00519"><label>*</label> Author to whom correspondence should be addressed; E-Mail: <email>jwv@engr.colostate.edu</email>; Tel.: +1-970-491-6697; Fax: +1-970-491-7727.</corresp>
      </author-notes>
      <pub-date pub-type="epub">
        <day>11</day>
        <month>12</month>
        <year>2012</year>
      </pub-date>
      <pub-date pub-type="collection"> <month>12</month>
        <year>2012</year>
      </pub-date>
      <volume>2</volume>
      <issue>4</issue>
      <fpage>519</fpage>
      <lpage>533</lpage>
      <history>
        <date date-type="received">
          <day>28</day>
          <month>08</month>
          <year>2012</year>
        </date>
        <date date-type="rev-recd">
          <day>21</day>
          <month>11</month>
          <year>2012</year>
        </date>
        <date date-type="accepted">
          <day>03</day>
          <month>12</month>
          <year>2012</year>
        </date>
      </history>
      <permissions>
        <copyright-statement>© 2012 by the authors; licensee MDPI, Basel, Switzerland.</copyright-statement>
        <copyright-year>2012</copyright-year>
        <license xmlns:xlink="http://www.w3.org/1999/xlink" license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/3.0/">
          <p>This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).</p>
        </license>
      </permissions>
      <abstract>
        <p>Tornadoes are a particularly devastating natural hazard that affect communities across the United States, particularly the Midwest and South. They are unique from an engineering point-of-view due to their very low probability of occurrence but often highly destructive consequences. The 2011 season was particularly devastating to the Southeastern portion of the U.S. This paper presents a single case study of a 2012 tornado that struck a single large rural light-frame wood house with an unconventional roof system. A fragility methodology was used as a tool to probabilistically study the loss of the roof system, and bound an Enhanced Fujita (EF) scale rating of the tornado. The tornado was initially rated as an EF3 tornado by the U.S. National Weather Service. However, following a detailed site inspection verified with numerical structural models, the tornado was downgraded to an EF2 tornado. As expected, the use of nail connections in a roof-to-wall connection resulted in a weaker link compared to a hurricane clip. The approach presented in this paper can be used as a supplement to the EF rating provided by U.S. National Weather Service meteorologists when unusual conditions in either the structure or surroundings exists.</p>
      </abstract>
      <kwd-group>
        <kwd>Tornado</kwd>
        <kwd>fragility</kwd>
        <kwd>EF rating</kwd>
        <kwd>roof failure</kwd>
        <kwd>residential structures</kwd>
        <kwd>light-frame </kwd>
      </kwd-group>
    </article-meta>
  </front>
  <body>
    <sec sec-type="intro">
      <title>1. Introduction</title>
      <p>On average, more than 1000 tornadoes are reported annually nationwide; however, regions in the Midwest and South experience a very high frequency of tornadoes [<xref ref-type="bibr" rid="B1-buildings-02-00519">1</xref>]. Tornadoes often result in significant injuries and deaths, as well as significant financial losses. In an average year, 80 deaths and 1500 injuries are reported due to tornadoes [<xref ref-type="bibr" rid="B2-buildings-02-00519">2</xref>]. According to a 2009 study, the average annual losses resulting from tornadoes are estimated to be $982 million. This is more than double the previous government estimates of $462 million [<xref ref-type="bibr" rid="B3-buildings-02-00519">3</xref>].</p>
      <p>One of the most destructive and deadly tornado years in U.S. history was 2011 which set numerous records. Several studies focusing on that season as a whole have been presented in papers over the last year [<xref ref-type="bibr" rid="B4-buildings-02-00519">4</xref>]. There were 1691 tornadoes reported in 2011 as compared to the previous decade average of 1274. In the month of April, 758 tornadoes were reported, which set the record for the highest number of tornadoes observed in a single month [<xref ref-type="bibr" rid="B5-buildings-02-00519">5</xref>]. The May 22nd tornado in Joplin, Missouri resulted in a record setting $3 billion in damage. Similarly, since standardization of tornado reporting began in 1950, the Joplin tornado broke the record for the most fatalities from a single tornado with 158 deaths. Total damages from tornado outbreaks in 2011 amounted to $28 billion [<xref ref-type="bibr" rid="B6-buildings-02-00519">6</xref>]. </p>
      <p>The literature is substantial with meteorological and structural engineering studies focusing on the formation and occurrence of tornadoes, tornado dynamics, wind pressure distribution, and missile risk analysis [<xref ref-type="bibr" rid="B7-buildings-02-00519">7</xref>,<xref ref-type="bibr" rid="B8-buildings-02-00519">8</xref>]. Over the past several decades a number of studies have also focused on forensic investigations and design of structures against tornadoes [<xref ref-type="bibr" rid="B9-buildings-02-00519">9</xref>,<xref ref-type="bibr" rid="B10-buildings-02-00519">10</xref>,<xref ref-type="bibr" rid="B11-buildings-02-00519">11</xref>].</p>
      <p>Light-frame wood construction comprises the majority (approximately 90%) of the residential building stock in the U.S. [<xref ref-type="bibr" rid="B12-buildings-02-00519">12</xref>]. These types of structures are extremely susceptible to natural hazards, especially tornadoes, due to their light weight. Current structural design codes do not consider design against tornadoes mainly due to the fact that they possess such a low occurrence probability compared with the high cost of retrofitting against a strong tornado. There is a very low probability of a structure being directly impacted by a tornado when considering the area of a tornado compared to the area of the U.S. Therefore, buildings in the U.S. are typically designed using loads from ASCE Standard 7 which were developed for straight line winds. However, tornadoes have been shown to produce uplift pressures that are significantly higher than straight line winds [<xref ref-type="bibr" rid="B13-buildings-02-00519">13</xref>].</p>
      <p>In early 2012 a winter tornado struck a two-story, single family house near the Koffman area of Tuscaloosa County, Alabama, in the Southeastern United States. After the building was hit by the tornado, a very thorough site investigation was conducted by the authors to determine the manner in which the roof system failed. This structure is used as an illustrative example in this paper to demonstrate the application of the fragility methodology to probabilistically study loss of a roof system in a residential wood-frame structure under tornado loads. In addition, fragilities can be used as a supplement to the Enhanced Fujita (EF) ratings provided by National Weather Service (NWS) meteorologists when unique structural (or other) conditions exist.</p>
    </sec>
    <sec>
      <title>2. Background</title>
      <sec>
        <title>2.1. Tornado Forces on a Structure</title>
        <p>When subjected to wind loads, structures experience simultaneous uplift and lateral forces, as shown in <xref ref-type="fig" rid="buildings-02-00519-f001">Figure 1</xref>. Lateral forces are resisted by the main wind force resisting system (MWFRS), while uplift forces are transferred from roof sheathing to roof-to-wall connection and finally to the foundation. A main wind-force resisting system is defined as the assemblage of structural elements that provide support and stability for the overall structure. Components and cladding, on the other hand, are the part of the building envelope that transfers the load to the MWFRS.</p>
        <fig id="buildings-02-00519-f001" position="anchor">
          <label>Figure 1</label>
          <caption>
            <p>Wind forces on a structure.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g001.tif"/>
        </fig>
        <p>The effect of straight line winds on structures has been studied extensively and has led to the development of the current design provisions [<xref ref-type="bibr" rid="B14-buildings-02-00519">14</xref>]. However, research has been less robust in terms of understanding the effects of tornadoes on structures with only a limited number of studies conducted on this topic [<xref ref-type="bibr" rid="B13-buildings-02-00519">13</xref>,<xref ref-type="bibr" rid="B15-buildings-02-00519">15</xref>,<xref ref-type="bibr" rid="B16-buildings-02-00519">16</xref>,<xref ref-type="bibr" rid="B17-buildings-02-00519">17</xref>]. Many of these studies present a combination of theoretical and experimental work with the main purpose of comparing the effects of tornadoes versus straight line winds. In all the studies, the authors concluded that, for the same reference wind speed, tornadoes result in higher wind loads (approximately 1.5–2 times) than straight winds. </p>
        <p>More specifically, Haan <italic>et al</italic>. [<xref ref-type="bibr" rid="B13-buildings-02-00519">13</xref>] simulated tornadoes on a one-story, gable roof building and compared the results with the wind provisions of ASCE 7-05. The authors found that the uplift coefficients for tornadoes exceeded the values specified in the provisions by a factor of 1.8–3.2 for the MWFRS. For components and cladding, the pressure coefficients obtained from the tornado simulations were found to be 1.4–2.4 times those of a straight line wind for the same reference wind velocity. Results obtained by Haan <italic>et al</italic>. are exclusively used as a basis of comparison between straight winds, e.g., hurricane, and tornado winds. These results were combined with the ASCE 7 wind provisions to form the basis for the tornado wind analysis in the present study. </p>
      </sec>
      <sec>
        <title>2.2. Wind Fragility</title>
        <p>The probability of a function or a limit state subjected to loading can be expressed as
		
		<disp-formula id="buildings-02-00519-i001">
		<inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-i001.tif"/>
		<label>(1)</label>
		</disp-formula>
		
		where <italic>P</italic>(<italic>D = x</italic>) is the probability that a demand will have a value of <italic>x</italic> and <italic>P</italic>(<italic>LS|D = x</italic>) is the conditional probability of the function. Demand can be any random variable describing intensity based on the type of analysis performed, e.g., 3-s gust wind speed for wind analysis, or spectral acceleration for earthquake analysis. For example, for wind speed, it is the probability that the wind speed, D, will have a value of 100 Km/h (62 mph). The conditional probability of the limit state given a certain demand is defined as the fragility [<xref ref-type="bibr" rid="B12-buildings-02-00519">12</xref>,<xref ref-type="bibr" rid="B18-buildings-02-00519">18</xref>,<xref ref-type="bibr" rid="B19-buildings-02-00519">19</xref>]. The limit state can be any type of performance expectation that is defined in terms of component or system response. For example, the limit state investigated in this study is the failure of roof-to-wall connections. Equation 1 shown above presents a fully coupled risk analysis; however, often structural engineers are more interested in determining the probability of failure given a certain demand, which is termed a fragility.</p>
        <p>The fragility of a structural system or component is often modeled using a lognormal distribution [<xref ref-type="bibr" rid="B12-buildings-02-00519">12</xref>,<xref ref-type="bibr" rid="B18-buildings-02-00519">18</xref>,<xref ref-type="bibr" rid="B19-buildings-02-00519">19</xref>], which can be written as
		
		<disp-formula id="buildings-02-00519-i002">
		<inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-i002.tif"/>
		<label>(2)</label>
		</disp-formula>
		
		where Ф(.) is the standard normal cumulative distribution function; <italic>λ<sub>R</sub></italic> represents the logarithmic median of capacity <italic>R</italic>; and <italic>ξ<sub>R</sub></italic> is the logarithmic standard deviation of capacity <italic>R</italic>. </p>
        <p><xref ref-type="fig" rid="buildings-02-00519-f002">Figure 2</xref> shows a suite of fragilities that is provided only for illustrative purposes. Each curve corresponds to a certain component. The fragilities are developed as a function of a certain demand, which in this study is the 3-s gust wind speed.</p>
        <fig id="buildings-02-00519-f002" position="anchor">
          <label>Figure 2</label>
          <caption>
            <p>Suite of fragilities for illustration.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g002.tif"/>
        </fig>
      </sec>
    </sec>
    <sec>
      <title>3. Case Study</title>
      <p>On January 23, 2012 a tornado touched down near the intersection of Alabama Hwy 171 and Koffman Ranch Rd. and struck a single family residence located in Tuscaloosa County, Alabama. It started around 2:42 am and ended at 2:43 am with a damage path length of approximately 0.74 km (0.46 miles) and a damage width of 366 m (400 yards) at its widest point [<xref ref-type="bibr" rid="B20-buildings-02-00519">20</xref>]. The house is a two story building built in 2005 and has approximately 336 sq.m (3614 sq.ft) of living area. Properties of the structure are given in <xref ref-type="table" rid="buildings-02-00519-t001">Table 1</xref> and the building plan and elevations are shown in <xref ref-type="fig" rid="buildings-02-00519-f003">Figure 3</xref>. The roof was constructed of LP 210 Joists spaced at 0.4 m (16 inch) on center. The joist were connected to the exterior walls using (5)10d toe nails while H3 hurricane clips with 1 inch. drywall screws were used at interior wall to joist connections. </p>
      <table-wrap id="buildings-02-00519-t001" position="float">
        <object-id pub-id-type="pii">buildings-02-00519-t001_Table 1</object-id>
        <label>Table 1</label>
        <caption>
          <p>Properties of the structure.</p>
        </caption>
        <table>
          <thead>
            <tr>
              <th colspan="2" align="center" valign="middle">Properties of the structure</th>
            </tr>
          </thead>
          <tbody>
            <tr>
              <td align="center" valign="middle">Plan dimension</td>
              <td align="center" valign="middle">7.3 m × 7.9 m (24.0 ft × 26.0 ft)</td>
            </tr>
            <tr>
              <td align="center" valign="middle">No. of stories</td>
              <td align="center" valign="middle">2</td>
            </tr>
            <tr>
              <td align="center" valign="middle">Roof type</td>
              <td align="center" valign="middle">mono slope</td>
            </tr>
            <tr>
              <td align="center" valign="middle">Roof slope</td>
              <td align="center" valign="middle">3:12 ( ~13◦)</td>
            </tr>
            <tr>
              <td align="center" valign="middle">Roof framing spacing</td>
              <td align="center" valign="middle">0.4 m o.c. (16” o.c.)</td>
            </tr>
            <tr>
              <td align="center" valign="middle">Overhang</td>
              <td align="center" valign="middle">0.9 m (3 ft)</td>
            </tr>
          </tbody>
        </table>
		</table-wrap>
      
	  <fig id="buildings-02-00519-f003" position="anchor">
        <label>Figure 3</label>
        <caption>
          <p>Building plan and elevation (All dimensions are given in meters).</p>
        </caption>
        <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g003.tif"/>
      </fig>
      <p>As mentioned previously, a detailed site inspection was conducted to investigate the loss of the roof system for the structure. <xref ref-type="fig" rid="buildings-02-00519-f004">Figure 4</xref> provides an overview of the site along with the extent and type of damage sustained. The entire roof system was removed without any further damage to the roof sheathing. Windows were broken due to wind-borne debris and some walls were partially damaged due to roof failure which are shown in <xref ref-type="fig" rid="buildings-02-00519-f005">Figure 5</xref>(a–c). In addition to structural damage to the building, trees around the structure also sustained damage with several trees snapped off at the trunk and several others uprooted, which is typical in moderate to strong tornadoes. </p>
      <fig id="buildings-02-00519-f004" position="anchor">
        <label>Figure 4</label>
        <caption>
          <p>Site plan and damage overview.</p>
        </caption>
        <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g004.tif"/>
      </fig>
      <fig id="buildings-02-00519-f005" position="anchor">
        <label>Figure 5</label>
        <caption>
          <p>(<bold>a</bold>) Roof entirely removed; (<bold>b</bold>) Windows broken due to wind-borne debris; (<bold>c</bold>) Walls partially damaged. </p>
        </caption>
        <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g005.tif"/>
      </fig>
    </sec>
    <sec>
      <title>4. Enhanced Fujita Scale</title>
      <p>The Enhanced Fujita (EF) scale [<xref ref-type="bibr" rid="B21-buildings-02-00519">21</xref>] is a method used to rate the intensity of tornadoes based on observed damages to structural and non-structural components following a wind event. The EF scale defines a number of Damage Indicators (DI) along with the descriptions for different Degrees of Damage (DOD) associated with the DIs. The DODs range from visible damage to total destruction. <xref ref-type="table" rid="buildings-02-00519-t002">Table 2</xref> shows the EF ratings and the estimated range of wind speeds associated with them. </p>
      <table-wrap id="buildings-02-00519-t002" position="float">
        <object-id pub-id-type="pii">buildings-02-00519-t002_Table 2</object-id>
        <label>Table 2</label>
        <caption>
          <p>Enhanced Fujita (EF) scale for tornado damage.</p>
        </caption>
        <table>
          <thead>
            <tr>
              <th colspan="2" align="center" valign="middle">EF Scale</th>
            </tr>
            <tr style="border-top:solid thin">
              <th align="center" valign="middle">EF rating</th>
              <th align="center" valign="middle">3 Second gust, Km/h (mph)</th>
            </tr>
          </thead>
          <tbody>
            <tr>
              <td align="center" valign="middle">0</td>
              <td align="center" valign="middle">105–138 (65–85)</td>
            </tr>
            <tr>
              <td align="center" valign="middle">1</td>
              <td align="center" valign="middle">139–178 (86–110)</td>
            </tr>
            <tr align="center">
              <td valign="middle">2</td>
              <td valign="middle">179–219 (111–135)</td>
            </tr>
            <tr>
              <td align="center" valign="middle">3</td>
              <td align="center" valign="middle">220–267 (136–165)</td>
            </tr>
            <tr>
              <td align="center" valign="middle">4</td>
              <td align="center" valign="middle">268–322 (166–200)</td>
            </tr>
            <tr>
              <td align="center" valign="middle">5</td>
              <td align="center" valign="middle">Over 323 (200)</td>
            </tr>
          </tbody>
        </table>
		</table-wrap>
    </sec>
    <sec>
      <title>5. Fragility Development</title>
      <p>As mentioned previously, uplift forces on a structure are transferred from roof sheathing to roof-to-wall connections and then to the foundation. A continuous vertical load path is important for structural stability. The vertical load path is analogous to a series system, meaning that these elements define the full vertical load path from roof to foundation. Since the roof sheathing and the walls did not sustain any significant damage based on visual inspection, the roof-to-wall connection failure was determined to be the main cause of failure. Therefore, fragilities were developed for this component of the vertical load path under the calculated uplift forces. To perform a fragility analysis, the limit states must be defined and statistics for different parameters are obtained. </p>
      <sec>
        <title>5.1. Limit States</title>
        <p>Wind induced uplift forces can result in failure of the roof-to-wall connections. Structural performance of the roof-to-wall connection is influenced by three main parameters: dead load, wind load, and resistance, thus the limit state can be written as 
		
		<disp-formula id="buildings-02-00519-i003">
		<inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-i003.tif"/>
		<label>(3)</label>
		</disp-formula>
		
		where <italic>D</italic> is the dead load; <italic>W</italic> is the uplift force due to wind acting on the roof-to-wall connection; and <italic>R</italic> is the uplift resistance capacity of the roof-to-wall connection. From the equation, it is observed that the dead load counteracts the wind load indicating its beneficial effect on performance. Based on Equation 3, a fragility curve is obtained using the conditional probability of <italic>g</italic>(<italic>x</italic>) <italic>&lt; 0</italic> [<xref ref-type="bibr" rid="B19-buildings-02-00519">19</xref>].</p>
      </sec>
      <sec>
        <title>5.2. Wind Load Statistics</title>
        <p>Wind loading on a structure can be expressed using the following equation [<xref ref-type="bibr" rid="B14-buildings-02-00519">14</xref>]:
		
		<disp-formula id="buildings-02-00519-i004">
		<inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-i004.tif"/>
		<label>(4)</label>
		</disp-formula>
		
		where <italic>q<sub>h</sub></italic> is the base pressure evaluated at mean roof height; <italic>G</italic> is defined as the gust factor; <italic>C<sub>p</sub></italic> is an external pressure coefficient; and <italic>C<sub>pi</sub></italic> is the internal pressure coefficient. The product of the gust factor and pressure coefficient is treated as a single variable and can be found in ASCE 7-10 [<xref ref-type="bibr" rid="B14-buildings-02-00519">14</xref>]. The base pressure is calculated using the following equation:
		
		<disp-formula id="buildings-02-00519-i005">
		<inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-i005.tif"/>
		<label>(5)</label>
		</disp-formula>
		
		where <italic>K<sub>c</sub></italic> is the tornado amplification factor which is a dimensionless quantity based on the work discussed earlier; <italic>K<sub>z</sub></italic> is the velocity pressure exposure coefficient; <italic>K<sub>d</sub></italic> is the wind directionality factor; <italic>K<sub>zt</sub></italic> is a the topographic factor; <italic>V</italic> is the basic wind speed (3-s gust wind speed at 10 m (33 ft) above the ground in an open terrain); and <italic>I</italic> is the importance factor.</p>
        <p>For the purpose of reliability analysis, each of the variables defined in Equations 4 and 5 are treated as random variables determined using information provided by Ellingwood and Tekie [<xref ref-type="bibr" rid="B22-buildings-02-00519">22</xref>] and Lee and Rosowsky [<xref ref-type="bibr" rid="B19-buildings-02-00519">19</xref>]. Statistics for wind load parameters are summarized in <xref ref-type="table" rid="buildings-02-00519-t003">Table 3</xref> below. The wind directionality factor, <italic>K<sub>d</sub></italic>, is taken as unity assuming that the wind direction is known. The topographic factor, <italic>K<sub>zt</sub></italic>, is also set equal to unity so the results will be independent of the local topography. For the purpose of this study, the tornado amplification factor, <italic>K<sub>c</sub></italic>, is treated as a random variable with a uniform distribution. The roof-to-wall connection is modeled as MWFRS; therefore, it is modeled as a uniformly distributed random variable in the range of 1.8 to 3.2. </p>
        <p>The internal pressure condition is assumed to remain “enclosed” throughout the entire analysis. A “partially enclosed” condition is assumed to occur only if elements of the building envelope, such as doors or windows, are breached. In this case, the building envelope is assumed to remain intact. The analysis performed by Haan <italic>et al</italic>. [<xref ref-type="bibr" rid="B13-buildings-02-00519">13</xref>] was based on an open terrain condition; therefore, the velocity pressure exposure coefficient, <italic>K<sub>z</sub></italic>, in this study is only evaluated for Exposure C (the open terrain condition). In addition, in contrast to straight line winds, tornado winds are not dependent on the fetch length, thus exposure type does not have an effect. </p>
		
		<table-wrap id="buildings-02-00519-t003" position="float">
          <object-id pub-id-type="pii">buildings-02-00519-t003_Table 3</object-id>
          <label>Table 3</label>
          <caption>
            <p>Summary of wind load statistics.</p>
          </caption>
          <table>
            <thead>
              <tr>
                <th align="center" valign="middle">Parameters</th>
                <th align="center" valign="middle">Category</th>
                <th align="center" valign="middle">Nominal</th>
                <th align="center" valign="middle">Mean</th>
                <th align="center" valign="middle">COV</th>
                <th align="center" valign="middle">Distribution type</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td align="center" valign="middle"><italic>K<sub>c</sub></italic></td>
                <td align="center" valign="middle">Tornado wind amplificationFactor-MWFRS</td>
                <td align="center" valign="middle">1.8–3.2</td>
                <td align="center" valign="middle">-</td>
                <td align="center" valign="middle">-</td>
                <td align="center" valign="middle">Uniform</td>
              </tr>
              <tr>
                <td rowspan="2" align="center" valign="middle"><italic>GC<sub>pi</sub>*</italic></td>
                <td align="center" valign="middle">Enclosed</td>
                <td align="center" valign="middle">0.18</td>
                <td align="center" valign="middle">0.15</td>
                <td align="center" valign="middle">0.33</td>
                <td rowspan="2" align="center" valign="middle">Normal</td>
              </tr>
              <tr>
                <td align="center" valign="middle">partially enclosed</td>
                <td align="center" valign="middle">0.55</td>
                <td align="center" valign="middle">0.46</td>
                <td align="center" valign="middle">0.33</td>
              </tr>
              <tr>
                <td align="center" valign="middle"><italic>K<sub>z</sub></italic></td>
                <td align="center" valign="middle">Exposure C</td>
                <td align="center" valign="middle">0.9</td>
                <td align="center" valign="middle">0.84</td>
                <td align="center" valign="middle">0.14</td>
                <td align="center" valign="middle">Normal</td>
              </tr>
              <tr>
                <td align="center" valign="middle"><italic>GC<sub>p</sub></italic></td>
                <td align="center" valign="middle">-</td>
                <td align="center" valign="middle">1.04</td>
                <td align="center" valign="middle">0.83</td>
                <td align="center" valign="middle">0.17</td>
                <td align="center" valign="middle">Normal</td>
              </tr>
              <tr>
                <td align="center" valign="middle"><italic>K<sub>d</sub></italic></td>
                <td colspan="5" align="center" valign="middle">deterministic (1.0)</td>
              </tr>
              <tr>
                <td align="center" valign="middle"><italic>K<sub>zt</sub></italic></td>
                <td colspan="5" align="center" valign="middle">deterministic (1.0)</td>
              </tr>
              <tr>
                <td align="center" valign="middle"><italic>I</italic></td>
                <td colspan="5" align="center" valign="middle">deterministic (1.0)</td>
              </tr>
            </tbody>
          </table>
		  <table-wrap-foot><fn>
		<p>* values based on [<xref ref-type="bibr" rid="B19-buildings-02-00519">19</xref>].</p>
		</fn></table-wrap-foot>
		</table-wrap>
        
        
      </sec>
      <sec>
        <title>5.3. Dead Load Statistics</title>
        <p>The dead load is defined as the self-weight of the members and is assumed to be constant in time. Dead load statistics are summarized in <xref ref-type="table" rid="buildings-02-00519-t004">Table 4</xref>. For the roof-to-wall connection, the dead load is taken as 0.717 kPa (15 psf) with a COV of 0.10.</p>
        <table-wrap id="buildings-02-00519-t004" position="float">
          <object-id pub-id-type="pii">buildings-02-00519-t004_Table 4</object-id>
          <label>Table 4</label>
          <caption>
            <p>Summary of dead load statistics.</p>
          </caption>
          <table>
            <thead>
              <tr>
                <th colspan="2" align="center" valign="middle">Summary of dead load statistics</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td align="center" valign="middle">Connection type</td>
                <td align="center" valign="middle">Roof-to-wall connection</td>
              </tr>
              <tr style="border-top:solid thin">
                <td rowspan="2" align="center" valign="middle">Mean</td>
                <td align="center" valign="middle">0.717 kPa</td>
              </tr>
              <tr>
                <td align="center" valign="middle">(15 psf)</td>
              </tr>
              <tr style="border-top:solid thin">
                <td align="center" valign="middle">COV</td>
                <td align="center" valign="middle">0.10</td>
              </tr>
              <tr>
                <td align="center" valign="middle">Distribution type</td>
                <td align="center" valign="middle">Normal</td>
              </tr>
              <tr>
                <td align="center" valign="middle">Source</td>
                <td align="center" valign="middle">[<xref ref-type="bibr" rid="B12-buildings-02-00519">12</xref>]</td>
              </tr>
            </tbody>
          </table>
		  </table-wrap>
      </sec>
      <sec>
        <title>5.4. Roof-to-Wall Connection Resistance</title>
        <p>Two types of roof-to-wall connections were observed during the site inspection, (5)10d and H3 hurricane clips. In the first type of connection, 10d common nails (3.76 mm (0.148 inch) diameter × 76 mm (3 in.) long) were used to connect the joists to the top plate of the exterior walls. In the second type, the joists were connected to the interior wall using an H3 hurricane clip; a schematic for this type of connection is shown in. This hardware is installed per manufacturer recommendations. The ultimate capacity of an H3 hurricane clip was not specifically known, only the design capacity. However, the ultimate and design capacities for an H2.5 hurricane clip were both known. Therefore, the ultimate capacity of the H3 clip was computed by multiplying its design capacity by the ratio of the ultimate to design capacity of the H2.5 clip. Overstrength consistency was assumed from the product manufacturer. In a similar manner, for (5)10d roof-to-wall connection, the mean capacity was obtained using the data for (2)16d fasteners. In both cases, Spruce-Pine-Fir (SPF) was used in the analysis. This procedure of using the ratio is explained Equation 6. The combined capacity and then the coefficient of variation (COV) for the combined section is presented in Equation 7. Specifically, the combined connection statistics were obtained by statistically combining the capacities of the H3 clip and the (5)10d connection. The mean was obtained by summing the means and the variance was obtained by taking the square root of the sum of the squares of variances for all the connections. This is possible since they are being modeled as normal variables. This is then used in developing the fragility for the combined resistance of these connections. The statistics for roof-to-wall connections used in the analysis are provided in <xref ref-type="table" rid="buildings-02-00519-t005">Table 5</xref>.</p>
        
		<disp-formula id="buildings-02-00519-i006">
		<inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-i006.tif"/>
		<label>(6)</label>
		</disp-formula>

        <disp-formula id="buildings-02-00519-i007">
		<inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-i007.tif"/>
		<label>(7)</label>
		</disp-formula>
		
		<table-wrap id="buildings-02-00519-t005" position="float">
          <object-id pub-id-type="pii">buildings-02-00519-t005_Table 5</object-id>
          <label>Table 5</label>
          <caption>
            <p>Roof-to-wall connection resistance statistics.</p>
          </caption>
          <table>
            <thead>
              <tr>
                <th align="center" valign="middle">Connection type</th>
                <th align="center" valign="middle">Mean</th>
                <th align="center" valign="middle">COV</th>
                <th align="center" valign="middle">Distribution type</th>
                <th align="center" valign="middle">Source</th>
              </tr>
            </thead>
            <tbody>
              <tr>
                <td rowspan="2" align="center" valign="middle">H3 clip</td>
                <td align="center" valign="middle">5.12 kN </td>
                <td rowspan="2" align="center" valign="middle">0.12</td>
                <td rowspan="2" align="center" valign="middle">Normal</td>
                <td rowspan="2" align="center" valign="middle">Equation 6 and [<xref ref-type="bibr" rid="B12-buildings-02-00519">12</xref>]</td>
              </tr>
              <tr>
                <td align="center" valign="middle">(1150.2 lbs)</td>
              </tr>
              <tr>
                <td rowspan="2" align="center" valign="middle">(5)10d toe nails</td>
                <td align="center" valign="middle">1.56 kN </td>
                <td rowspan="2" align="center" valign="middle">0.16</td>
                <td rowspan="2" align="center" valign="middle">Normal</td>
                <td rowspan="2" align="center" valign="middle">[<xref ref-type="bibr" rid="B4-buildings-02-00519">4</xref>]</td>
              </tr>
              <tr>
                <td align="center" valign="middle">(351.6 lbs)</td>
              </tr>
              <tr>
                <td rowspan="2" align="center" valign="middle">Combined</td>
                <td align="center" valign="middle">8.2 kN </td>
                <td rowspan="2" align="center" valign="middle">0.09</td>
                <td rowspan="2" align="center" valign="middle">Normal</td>
                <td rowspan="2" align="center" valign="middle">Equation 7</td>
              </tr>
              <tr>
                <td align="center" valign="middle">(1805.4 lbs) </td>
              </tr>
            </tbody>
          </table>
		  </table-wrap>
        
		<fig id="buildings-02-00519-f006" position="anchor">
          <label>Figure 6</label>
          <caption>
            <p>Joist connection to the top plates.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g006.tif"/>
        </fig>
        
        <p><xref ref-type="fig" rid="buildings-02-00519-f007">Figure 7</xref> presents a lateral section of the roof with the applied wind pressure. Fragilities for the roof-to-wall connections were developed as defined in Equation 3. The analysis was performed using Monte-Carlo simulation with the statistics for wind, dead load, and uplift resistance described above. Fragilities were developed for two different conditions, individual and combined. <xref ref-type="fig" rid="buildings-02-00519-f008">Figure 8</xref> illustrates the tributary area and the loading condition considered in the analysis. <xref ref-type="fig" rid="buildings-02-00519-f008">Figure 8</xref>a presents the loading considered for the individual cases while the combined case is explained in <xref ref-type="fig" rid="buildings-02-00519-f008">Figure 8</xref>b.</p>
        <fig id="buildings-02-00519-f007" position="anchor">
          <label>Figure 7</label>
          <caption>
            <p>Roof uplift pressure.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g007.tif"/>
        </fig>
        <fig id="buildings-02-00519-f008" position="anchor">
          <label>Figure 8</label>
          <caption>
            <p>Loading conditions considered for fragility analysis (<bold>a</bold>) Individual case; (<bold>b</bold>) Combined case.</p>
          </caption>
          <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g008.tif"/>
        </fig>
      </sec>
    </sec>
    <sec sec-type="results">
      <title>6. Results and Discussion</title>
      <p>Fragilities for all three different conditions are shown in <xref ref-type="fig" rid="buildings-02-00519-f009">Figure 9</xref>. The individual case examines individual failure of each of these connections, and in the combined case, simultaneous failure of both of these connections is investigated. The combined case used in this study is performed since the order of the failure is not known and likely occurred at the same time. This condition, along with the other individual conditions, provides insight into the failure mechanism of the roof system. </p>
      <fig id="buildings-02-00519-f009" position="anchor">
        <label>Figure 9</label>
        <caption>
          <p>Fragilities for roof-to-wall connection.</p>
        </caption>
        <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g009.tif"/>
      </fig>
      <p>Recall that fragilities are often modeled as lognormal distributions; therefore, the lognormal parameters of these fragilities are given in <xref ref-type="table" rid="buildings-02-00519-t006">Table 6</xref>. </p>
      <table-wrap id="buildings-02-00519-t006" position="float">
        <object-id pub-id-type="pii">buildings-02-00519-t006_Table 6</object-id>
        <label>Table 6</label>
        <caption>
          <p>Lognormal parameters for roof-to-wall connections.</p>
        </caption>
        <table>
          <thead>
            <tr>
              <th rowspan="2" align="center" valign="middle">Connection Type</th>
              <th colspan="2" align="center" valign="middle">Parameters</th>
            </tr>
            <tr style="border-top:solid thin">
              <th align="center" valign="middle">λ</th>
              <th align="center" valign="middle">ξ</th>
            </tr>
          </thead>
          <tbody>
            <tr>
              <td align="center" valign="middle">H3</td>
              <td align="center" valign="middle">4.891</td>
              <td align="center" valign="middle">0.1448</td>
            </tr>
            <tr>
              <td align="center" valign="middle">(5)10d</td>
              <td align="center" valign="middle">4.464</td>
              <td align="center" valign="middle">0.1458</td>
            </tr>
            <tr>
              <td align="center" valign="middle">Combined</td>
              <td align="center" valign="middle">4.718</td>
              <td align="center" valign="middle">0.1409</td>
            </tr>
          </tbody>
        </table>
		</table-wrap>
      <p>As seen in <xref ref-type="fig" rid="buildings-02-00519-f009">Figure 9</xref>, for an EF2 (111–135 mph) tornado, there is a probability of failure greater than 95% for the (5)10d connection. However, the probability of failure is 10%–55% and 40%–90% for the H3 hurricane clip and the combined condition, respectively. This indicates that the nail connection is a much weaker link in the roof-to-wall connection than the hurricane clip, as expected. Roofs generally have a reasonable degree of redundancy associated with them; however, in this case it is believed that a single connection failure led to progressive failure and eventual loss of the entire roof system. Based on the site inspection and examination of <xref ref-type="fig" rid="buildings-02-00519-f009">Figure 9</xref>, it is believed that failure of the (5)10d connection might have initiated the roof failure. This failure mechanism can be best explained by <xref ref-type="fig" rid="buildings-02-00519-f010">Figure 10</xref> and <xref ref-type="fig" rid="buildings-02-00519-f011">Figure 11</xref> which examine a condition when the (5)10d nail connection has failed and the wind pressure is redistributed to the hurricane clip. Looking at <xref ref-type="fig" rid="buildings-02-00519-f010">Figure 10</xref>b, for an EF2 tornado there is 70% to approximately 100% probability of failure for an H3 clip after the nailed connection has failed. However, in reality this probability is much higher than shown in the figure, since the capacity statistics normally used for an H3 clip are based on using (4)8d nails while in the home investigated, the actual connection had used drywall screws. The use of drywall screws reduces the capacity of the connection, which in turn, increases the failure probability of the connection. </p>
      <fig id="buildings-02-00519-f010" position="anchor">
        <label>Figure 10</label>
        <caption>
          <p>(<bold>a</bold>) Loading condition considered for the fragility analysis; (<bold>b</bold>) Fragility for H3 hurricane clip when nail connection has failed.</p>
        </caption>
        <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g010.tif"/>
      </fig>
      <fig id="buildings-02-00519-f011" position="anchor">
        <label>Figure 11</label>
        <caption>
          <p>Roof failure mechanism.</p>
        </caption>
        <graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="buildings-02-00519-g011.tif"/>
      </fig>
      <p>The results indicate the importance of construction methods and practices on the performance of a structure under natural hazards loading such as a moderate tornado. Use of nail connections proved to be the weaker link in a roof-to-wall connection in comparison to a hurricane clip as one would expect. The tornado resulted in the loss of the roof system as well as other significant financial losses. </p>
    </sec>
    <sec sec-type="conclusions">
      <title>7. Conclusions</title>
      <p>This paper presented a systematic assessment of the loss of a roof system in a two-story residential wood frame residential building that was impacted by a winter tornado in Tuscaloosa County, Alabama. A site inspection was conducted following the tornado and the roof-to-wall connection failure was determined to be the main cause of failure. Fragilities were developed for different roof-to-wall connections to determine the manner in which the roof failed. This also provided an insight into the tornado wind speed that resulted in the observed failure and formed the basis for a more quantitative analysis of the EF rating for this particular case study. </p>
      <p>Based on the discussion presented in the previous section, an EF2 tornado most likely resulted in the loss of the roof system for the building under consideration. The Enhanced Fujita scale was used to rate the intensity of the tornadoes based on observed damage during the site survey. The tornado was initially rated as an EF3 tornado but following a site inspection by the authors, the tornado rating was downgraded to an EF2 tornado. In specific cases, it may be possible to assist in determining EF ratings using the fragility methodology described herein, particularly when buildings are atypical. It is important to note that the results of this study are probabilistic and quantitative and that there are uncertainties involved in the analysis. </p>
      <p>This study demonstrates the application of the fragility methodology in probabilistic assessment of structures against tornado loads with a focus on the roof-to-wall connection component of the vertical load path. Since tornado wind speeds are difficult to measure directly, the EF scale is used to rate the intensity of the tornadoes based on the damage observed. The approach offered in this study can be used as a supplement to the EF ratings. </p>
    </sec>
  </body>
  <back>
    <ack>
      <title>Acknowledgements</title>
      <p>The first author acknowledges the Garry Neil Drummond Endowed Chair funds at the University of Alabama and the George T. Abell Professorship funds at Colorado State University. Thank you also to colleagues at the National Weather Service for providing the location and their assessment of the tornado to the authors. </p>
    </ack>
    <ref-list>
      <title>References</title>
      <ref id="B1-buildings-02-00519">
        <label>1.</label>
        <citation citation-type="web">
          <collab>National Climatic Data Center U.S.</collab>
          <article-title>Tornado Climatology</article-title>
          <comment>Available online:<ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://www.ncdc.noaa.gov/oa/climate/severeweather/tornadoes.html" ext-link-type="uri">http://www.ncdc.noaa.gov/oa/climate/severeweather/tornadoes.html</ext-link></comment>
          <access-date>(accessed on 25 March 2012)</access-date>
        </citation>
      </ref>
      <ref id="B2-buildings-02-00519">
        <label>2.</label>
        <citation citation-type="web">
          <article-title>NOAA Severe Weather Safety: Tornado Guide</article-title>
          <comment>Available online:<ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://www.nssl.noaa.gov/edu/safety/tornadoguide.html" ext-link-type="uri">http://www.nssl.noaa.gov/edu/safety/tornadoguide.html</ext-link></comment>
          <access-date>(accessed on 24 March 2012)</access-date>
        </citation>
      </ref>
      <ref id="B3-buildings-02-00519">
        <label>3.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Changnon</surname>
              <given-names>S.A.</given-names>
            </name>
          </person-group>
          <article-title>Tornado losses in the United States</article-title>
          <source>Nat. Hazards Rev.</source>
          <year>2009</year>
          <volume>10</volume>
          <fpage>145</fpage>
          <lpage>150</lpage>
          <pub-id pub-id-type="doi">10.1061/(ASCE)1527-6988(2009)10:4(145)</pub-id>
        </citation>
      </ref>
      <ref id="B4-buildings-02-00519">
        <label>4.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Van de Lindt</surname>
              <given-names>J.W.</given-names>
            </name>
            <name>
              <surname>Pei</surname>
              <given-names>S.</given-names>
            </name>
            <name>
              <surname>Dao</surname>
              <given-names>T.</given-names>
            </name>
            <name>
              <surname>Graettinger</surname>
              <given-names>A.</given-names>
            </name>
            <name>
              <surname>Prevatt</surname>
              <given-names>D.O.</given-names>
            </name>
            <name>
              <surname>Gupta</surname>
              <given-names>R.</given-names>
            </name>
            <name>
              <surname>Coulbourne</surname>
              <given-names>W.</given-names>
            </name>
          </person-group>
          <article-title>A dual-objective-based Tornado design philosophy</article-title>
          <source>J. Struct. Eng. ASCE</source>
          <year>2012</year>
          <comment>in press</comment>
        </citation>
      </ref>
      <ref id="B5-buildings-02-00519">
        <label>5.</label>
        <citation citation-type="web">
          <article-title>NOAA 2011 Tornado Information</article-title>
          <comment>Available online:<ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://www.noaanews.noaa.gov/2011_tornado_information.html" ext-link-type="uri">http://www.noaanews.noaa.gov/2011_tornado_information.html</ext-link></comment>
          <access-date>(accessed on 25 March 2012)</access-date>
        </citation>
      </ref>
      <ref id="B6-buildings-02-00519">
        <label>6.</label>
        <citation citation-type="web">
          <article-title>NOAA National Climatic Data Center State of the Climate: Tornadoes for Annual 2011</article-title>
          <comment>Available online:<ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://www.ncdc.noaa.gov/sotc/tornadoes/2011/13" ext-link-type="uri">http://www.ncdc.noaa.gov/sotc/tornadoes/2011/13</ext-link></comment>
          <access-date>(accessed on 24 March 2012)</access-date>
        </citation>
      </ref>
      <ref id="B7-buildings-02-00519">
        <label>7.</label>
        <citation citation-type="book">
          <person-group person-group-type="author">
            <name>
              <surname>Davies-Jones</surname>
              <given-names>R.P.</given-names>
            </name>
          </person-group>
          <article-title>Tornado dynamics</article-title>
          <source>Thunderstorms: A Social and Technological Documentary</source>
          <person-group person-group-type="editor">
            <name>
              <surname>Kessler</surname>
              <given-names>E.</given-names>
            </name>
          </person-group>
          <publisher-name>University of Oklahoma Press</publisher-name>
          <publisher-loc>Norman, OK, USA</publisher-loc>
          <year>1986</year>
          <fpage>197</fpage>
          <lpage>236</lpage>
        </citation>
      </ref>
      <ref id="B8-buildings-02-00519">
        <label>8.</label>
        <citation citation-type="confproc">
          <person-group person-group-type="author">
            <name>
              <surname>Forbes</surname>
              <given-names>G.S.</given-names>
            </name>
          </person-group>
          <article-title>Meteorological aspects of high-impact Tornado outbreaks</article-title>
          <source>Symposium on the Challenges of Severe Convective Storms</source>
          <conf-loc>Atlanta, GA, USA</conf-loc>
          <conf-date>29 January–2 February 2006</conf-date>
        </citation>
      </ref>
      <ref id="B9-buildings-02-00519">
        <label>9.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Minor</surname>
              <given-names>J.E.</given-names>
            </name>
            <name>
              <surname>Mehta</surname>
              <given-names>K.C.</given-names>
            </name>
            <name>
              <surname>McDonald</surname>
              <given-names>J.R.</given-names>
            </name>
          </person-group>
          <article-title>Failure of structures due to extreme winds</article-title>
          <source>J. Struct. Div.</source>
          <year>1972</year>
          <volume>98</volume>
          <fpage>2455</fpage>
          <lpage>2472</lpage>
        </citation>
      </ref>
      <ref id="B10-buildings-02-00519">
        <label>10.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Minor</surname>
              <given-names>J.E.</given-names>
            </name>
            <name>
              <surname>Mehta</surname>
              <given-names>K.C.</given-names>
            </name>
            <name>
              <surname>McDonald</surname>
              <given-names>J.R.</given-names>
            </name>
          </person-group>
          <article-title>Air Flow around buildings as reflected in failure modes</article-title>
          <source>ASHRAE Trans.</source>
          <year>1976</year>
          <volume>82</volume>
          <fpage>1061</fpage>
          <lpage>1071</lpage>
        </citation>
      </ref>
      <ref id="B11-buildings-02-00519">
        <label>11.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>McDonald</surname>
              <given-names>J.R.</given-names>
            </name>
            <name>
              <surname>Mehta</surname>
              <given-names>K.C.</given-names>
            </name>
            <name>
              <surname>Minor</surname>
              <given-names>J.E.</given-names>
            </name>
          </person-group>
          <article-title>Tornado-resistant design of nuclear power plant structures</article-title>
          <source>Nucl. Saf.</source>
          <year>1974</year>
          <volume>15</volume>
          <fpage>432</fpage>
          <lpage>439</lpage>
        </citation>
      </ref>
      <ref id="B12-buildings-02-00519">
        <label>12.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Ellingwood</surname>
              <given-names>B.R.</given-names>
            </name>
            <name>
              <surname>Rosowsky</surname>
              <given-names>D.V.</given-names>
            </name>
            <name>
              <surname>Li</surname>
              <given-names>Y.</given-names>
            </name>
            <name>
              <surname>Kim</surname>
              <given-names>J.H.</given-names>
            </name>
          </person-group>
          <article-title>Fragility assessment of light-frame wood construction subjected to wind and earthquake hazards</article-title>
          <source>J. Struct. Eng.</source>
          <year>2004</year>
          <volume>130</volume>
          <fpage>1921</fpage>
          <lpage>1930</lpage>
        <pub-id pub-id-type="doi">10.1061/(ASCE)0733-9445(2004)130:12(1921)</pub-id></citation>
      </ref>
      <ref id="B13-buildings-02-00519">
        <label>13.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Haan</surname>
              <given-names>F.L.</given-names>
            </name>
            <name>
              <surname>Balaramudu</surname>
              <given-names>V.K.</given-names>
            </name>
            <name>
              <surname>Sarkar</surname>
              <given-names>P.P.</given-names>
            </name>
          </person-group>
          <article-title>Tornado-induced wind loads on a low-rise building</article-title>
          <source>J. Struct. Eng.</source>
          <year>2010</year>
          <volume>136</volume>
          <fpage>106</fpage>
          <lpage>116</lpage>
        <pub-id pub-id-type="doi">10.1061/(ASCE)ST.1943-541X.0000093</pub-id></citation>
      </ref>
      <ref id="B14-buildings-02-00519">
        <label>14.</label>
        <citation citation-type="book">
          <collab>American Society of Civil Engineers (ASCE)</collab>
          <source>Minimum Design Loads for Buildings and Other Structures</source>
          <publisher-name>ACSE</publisher-name>
          <publisher-loc>Reston, VA, USA</publisher-loc>
          <year>2010</year>
        </citation>
      </ref>
      <ref id="B15-buildings-02-00519">
        <label>15.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Sengupta</surname>
              <given-names>A.</given-names>
            </name>
            <name>
              <surname>Haan</surname>
              <given-names>F.L.</given-names>
            </name>
            <name>
              <surname>Sarkar</surname>
              <given-names>P.P.</given-names>
            </name>
            <name>
              <surname>Balaramudu</surname>
              <given-names>V.</given-names>
            </name>
          </person-group>
          <article-title>Transient loads on buildings in microburst and tornado winds</article-title>
          <source>J. Wind Eng. Ind. Aerodyn.</source>
          <year>2008</year>
          <volume>96</volume>
          <fpage>2173</fpage>
          <lpage>2187</lpage>
        <pub-id pub-id-type="doi">10.1016/j.jweia.2008.02.050</pub-id></citation>
      </ref>
      <ref id="B16-buildings-02-00519">
        <label>16.</label>
        <citation citation-type="confproc">
          <person-group person-group-type="author">
            <name>
              <surname>Alrasheedi</surname>
              <given-names>N.H.</given-names>
            </name>
            <name>
              <surname>Selvam</surname>
              <given-names>R.P.</given-names>
            </name>
          </person-group>
          <article-title>Tornado forces on different building sizes using computer modeling</article-title>
          <source>ASME Early Career Technical Conference</source>
          <conf-loc>Fayetteville, AR, USA</conf-loc>
          <conf-date>31 March–2 April 2011</conf-date>
        </citation>
      </ref>
      <ref id="B17-buildings-02-00519">
        <label>17.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Selvam</surname>
              <given-names>R.P.</given-names>
            </name>
            <name>
              <surname>Millett</surname>
              <given-names>P.C.</given-names>
            </name>
          </person-group>
          <article-title>Computer modeling of tornado forces on a cubic building using large eddy simulation</article-title>
          <source>J. Ark. Acad. Sci.</source>
          <year>2003</year>
          <volume>57</volume>
          <fpage>140</fpage>
          <lpage>146</lpage>
        </citation>
      </ref>
      <ref id="B18-buildings-02-00519">
        <label>18.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Rosowsky</surname>
              <given-names>D.V.</given-names>
            </name>
            <name>
              <surname>Ellingwood</surname>
              <given-names>B.R.</given-names>
            </name>
          </person-group>
          <article-title>Performance-based engineering of wood frame housing: Fragility analysis methodology</article-title>
          <source>J. Struct. Eng.</source>
          <year>2002</year>
          <volume>128</volume>
          <fpage>32</fpage>
          <lpage>38</lpage>
        <pub-id pub-id-type="doi">10.1061/(ASCE)0733-9445(2002)128:1(32)</pub-id></citation>
      </ref>
      <ref id="B19-buildings-02-00519">
        <label>19.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Lee</surname>
              <given-names>K.H.</given-names>
            </name>
            <name>
              <surname>Rosowsky</surname>
              <given-names>D.V.</given-names>
            </name>
          </person-group>
          <article-title>Fragility assessment for roof sheathing failure in high wind regions</article-title>
          <source>Eng. Struct.</source>
          <year>2005</year>
          <volume>27</volume>
          <fpage>857</fpage>
          <lpage>868</lpage>
        <pub-id pub-id-type="doi">10.1016/j.engstruct.2004.12.017</pub-id></citation>
      </ref>
      <ref id="B20-buildings-02-00519">
        <label>20.</label>
        <citation citation-type="web">
          <article-title>NOAA National Weather Service: Weather Forecast Office</article-title>
          <comment>Available online:<ext-link xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="http://www.srh.noaa.gov/bmx/?n=event_01232012koffman" ext-link-type="uri">http://www.srh.noaa.gov/bmx/?n=event_01232012koffman</ext-link></comment>
          <access-date>(accessed on 25 March 2012)</access-date>
        </citation>
      </ref>
      <ref id="B21-buildings-02-00519">
        <label>21.</label>
        <citation citation-type="book">
          <person-group person-group-type="author">
            <name>
              <surname>McDonald</surname>
              <given-names>J.R.</given-names>
            </name>
            <name>
              <surname>Mehta</surname>
              <given-names>K.C.</given-names>
            </name>
          </person-group>
          <source>A Recommendation for an Enhanced Fujita Scale</source>
          <publisher-name>Wind Science and Engineering Center, Texas Tech University</publisher-name>
          <publisher-loc>Lubbock, TX, USA</publisher-loc>
          <year>2006</year>
        </citation>
      </ref>
      <ref id="B22-buildings-02-00519">
        <label>22.</label>
        <citation citation-type="journal">
          <person-group person-group-type="author">
            <name>
              <surname>Ellingwood</surname>
              <given-names>B.R.</given-names>
            </name>
            <name>
              <surname>Tekie</surname>
              <given-names>P.B.</given-names>
            </name>
          </person-group>
          <article-title>Wind load statistics for probability-based structural design</article-title>
          <source>J. Struct. Eng.</source>
          <year>1999</year>
          <volume>125</volume>
          <fpage>453</fpage>
          <lpage>463</lpage>
        <pub-id pub-id-type="doi">10.1061/(ASCE)0733-9445(1999)125:4(453)</pub-id></citation>
      </ref>
    </ref-list>
  </back>
</article>
