Next Article in Journal
Effect of Different Current Values on Microstructure and Mechanical Properties of Microalloyed Steels Joined by the Submerged Arc Welding Method
Previous Article in Journal
Hot Deformation Behavior of As-Cast and Homogenized Al0.5CoCrFeNi High Entropy Alloys
Article Menu

Export Article

Open AccessArticle
Metals 2016, 6(11), 278; doi:10.3390/met6110278

Results of High-Temperature Heating Test for Irradiated U-10Zr(-5Ce) with T92 Cladding Fuel

Korea Atomic Energy Research Institute, 989-111 Daedeok-daero, Yuseong, Daejeon 305-353, Korea
*
Author to whom correspondence should be addressed.
Academic Editor: Hugo F. Lopez
Received: 28 September 2016 / Revised: 9 November 2016 / Accepted: 11 November 2016 / Published: 15 November 2016
View Full-Text   |   Download PDF [4621 KB, uploaded 15 November 2016]   |  

Abstract

A microstructure observation using an optical microscope, SEM and EPMA was performed for the irradiated U-10Zr and U-10Zr-5Ce fuel slugs with a T92 cladding specimen after a high-temperature heating test. Also, the measured eutectic penetration rate was compared with the value predicted by the existing eutectic penetration correlation being used for design and modeling purposes. The heating temperature and duration time for the U-10Zr/T92 specimen were 750 °C and 1 h, and those for the U-10Zr-5Ce/T92 specimen were 800 °C and 1 h. In the case of the U-10Zr/T92 specimen, the migration phenomena of U, Zr, Fe, and Cr as well as the Nd lanthanide fission product were observed at the eutectic melting region. The measured penetration rate was similar to the value predicted by the existing eutectic penetration rate correlation. In addition, when comparing with measured eutectic penetration rates for the unirradiated U-10Zr fuel slug with FMS (ferritic martensitic steel, HT9 or Gr.91) cladding specimens which had been reported in the literature, the measured eutectic penetration rate for the irradiated fuel specimen was higher than that for the unirradiated U-10Zr specimen. In the case of the U-10Zr-5Ce/T92 specimen in which there had been a gap between the fuel slug and cladding after the irradiation test, the eutectic melting region was not found because contact between the fuel slug and cladding did not take place during the heating test. View Full-Text
Keywords: sodium-cooled fast reactor; metallic fuel; eutectic melting; lanthanide fission product sodium-cooled fast reactor; metallic fuel; eutectic melting; lanthanide fission product
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Kim, J.-H.; Cheon, J.-S.; Lee, B.-O.; Kim, J.-H.; Kim, H.-M.; Yoo, B.-O.; Jung, Y.-H.; Ahn, S.-B.; Lee, C.-B. Results of High-Temperature Heating Test for Irradiated U-10Zr(-5Ce) with T92 Cladding Fuel. Metals 2016, 6, 278.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Metals EISSN 2075-4701 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert