Polymers 2015, 7(12), 2522-2534; doi:10.3390/polym7121530

Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability

Department of Polymer Engineering, Faculty of Technology, Tomas Bata University in Zlin, Vavreckova 275, 762 72 Zlin, Czech Republic
Academic Editor: Seth Darling
Received: 11 November 2015 / Revised: 26 November 2015 / Accepted: 26 November 2015 / Published: 2 December 2015
View Full-Text   |   Download PDF [2382 KB, uploaded 2 December 2015]   |  

Abstract

Two ethylene-octene copolymers (EOC) with the same melt flow index (MFI = 3 g/10 min) but different octene contents, being 20 and 35 wt % (EOC-20 and EOC-35), were compared with regard to sensitivity to electron beam crosslinking. Dynamic mechanical analysis (DMA) revealed a large influence of the octene content on the storage modulus and the glass transition temperature (Tg) but a smaller influence of irradiation on the properties below melting point (Tm). Rheology at 150 °C pointed out large differences in samples crosslinked in the 0–60 kGy range and at lower frequencies (0.1–1 Hz). The loss factor tanδ confirmed that before irradiation the two copolymers were very similar, while after irradiation to 120 kGy, the EOC-35 had considerably lower tanδ than EOC-20, which corresponds to a better elasticity (or a higher level of crosslinking). A high-temperature creep test showed a considerably lower creep for EOC with a higher octene content. An analysis of the insoluble gel content exhibited higher values for EOC-35 confirming a higher level of crosslinking. Analysis according to the Charlesby-Pinner equation revealed increased crosslinking-to-scission ratio, G(X)/G(S), for EOC-35. While the G(X) value changed only slightly, a significant decrease in the G(S) value was discovered. View Full-Text
Keywords: ethylene-octene copolymer; electron beam irradiation; crosslinking; rheology; creep ethylene-octene copolymer; electron beam irradiation; crosslinking; rheology; creep
Figures

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Supplementary material

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Svoboda, P. Influence of Branching Density in Ethylene-Octene Copolymers on Electron Beam Crosslinkability. Polymers 2015, 7, 2522-2534.

Show more citation formats Show less citations formats

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Polymers EISSN 2073-4360 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top