Optimization of a Heliostat Field Layout on Annual Basis Using a Hybrid Algorithm Combining Particle Swarm Optimization Algorithm and Genetic Algorithm

School of Energy, Power and Mechanical Engineering, North China Electric Power University, Beijing 102206, China
*
Author to whom correspondence should be addressed.
Energies 2017, 10(11), 1924; https://doi.org/10.3390/en10111924
Submission received: 25 October 2017 / Revised: 13 November 2017 / Accepted: 15 November 2017 / Published: 21 November 2017
(This article belongs to the Section F: Electrical Engineering)

Abstract

:
Of all the renewable power generation technologies, solar tower power system is expected to be the most promising technology that is capable of large-scale electricity production. However, the optimization of heliostat field layout is a complicated process, in which thousands of heliostats have to be considered for any heliostat field optimization process. Therefore, in this paper, in order to optimize the heliostat field to obtain the highest energy collected per unit cost (ECUC), a mathematical model of a heliostat field and a hybrid algorithm combining particle swarm optimization algorithm and genetic algorithm (PSO-GA) are coded in Matlab and the heliostat field in Lhasa is investigated as an example. The results show that, after optimization, the annual efficiency of the heliostat field increases by approximately six percentage points, and the ECUC increases from 12.50 MJ/USD to 12.97 MJ/USD, increased about 3.8%. Studies on the key parameters indicate that: for un-optimized filed, ECUC first peaks and then decline with the increase of the number of heliostats in the first row of the field (Nhel1). By contrast, for optimized field, ECUC increases with Nhel1. What is more, for both the un-optimized and optimized field, ECUC increases with tower height and decreases with the cost of heliostat mirror collector.

1. Introduction

In China, over 60% of power generated from the coal-fired power plant, which contributes 40% of total national emissions [1]. What is more, because of the severe pressure from the international community to reduce carbon emissions, China has started to focus on generating power from renewable energy [2]. Of all the renewable energy, solar energy is arguably one of the most favorable solutions for the green power generation and concentrating solar power (CSP) technologies are expected to be the most promising technologies that are capable of large-scale electricity production [3,4,5]. It is estimated that CSP could meet approximately 11% of the global demand for electricity by 2050 [5]. Among all of the CSP technologies, named the parabolic trough collector, the linear Fresnel reflector, the parabolic dish system, and the solar tower, the solar tower technology has unique advantages when compared with other CSP technologies, which can provide the greatest potential for high efficiency and scalability [6]. In a solar tower power plant (STPP), solar energy is collected by the heliostat to produce steam to drive electrical generators. From the previous studies [3,7,8], it has found that the heliostat field contributes about 50% to the total cost and causes power losses by 40% in STPPs. For this reason, the design and optimization of the heliostat field layout are very important and the heliostat field remains an active research field.
Several studies have developed various codes and methods, such as HFLCAL [9], MIRVAL [10], DELSOL [11], and Campo [12] to simulate the optical efficiency of a heliostat field. Because of the high computational cost and variables that are considered for a heliostat field, a major limitation of heliostat layout optimization is computational time. Thus, many attempts have been made to develop methods for a more accurate and faster calculation of the efficiency of the heliostat field. Besarati et al. presented a method to determine the heliostats with the greatest potential for shadowing and blocking a heliostat, which can significantly reduce the computational time [7]. Cádiz et al. proposed a new method that can optimize azimuthal distances between heliostats for a given time to accurately calculate of shadowing and blocking factor [13]. Wei et al. developed a new code for heliostat field layout design, with which the heliostat can be placed with a higher efficiency and a faster response speed of the design and optimization can be obtained [8,14]. Kim et al. adopted polygon clipping algorithm in estimating the shadowing and blocking efficiency, which can be as fast as the projection method, and as accurate and as flexible as the discretization method. The presented method has been tested on PS10 heliostat layout with two cases: unconstrained and constrained heliostat field area. Results show that both cases result in an equal improvement of 0.6%, while the heliostat field area is reduced by 3.4% for constrained and is increased by 1.8% for unconstrained [15].
On the other hand, some authors focus on the optimization of heliostat field layout to improve its efficiency. Noone et al. developed a new computationally efficient heliostat field layout model. Results indicate that the developed model was able to improve the PS10 efficiency by 0.36% and to reduce the land area by 15.8% [16]. Gadalla et al. carried out comparative analyses between two circular heliostat field layouts. The results indicate that the optimum weighted efficiencies for Campo radial-staggered and biomimetic spiral layouts are similar, 61.6% and 61.5%, respectively [17]. Eddhibi et al. designed and analyzed an efficient heliostat field layout with minimum losses due to the shadowing and blocking effect [18]. However, because of the high complexity of the heliostat field, the optimum design of the heliostat field of STPPs remains a challenge. Therefore, some intelligence algorithms with better global search abilities over conventional optimization algorithms have been implemented to the optimization of heliostat fields. Zhang et al. presented an efficient code combining Rosen projection method and simulated annealing smart algorithm to optimize the heliostat field layout [19]. Piroozmand et al. optimized a multi-tower heliostat field layout using particle swarm optimization (PSO) algorithm [3]. Of all the intelligence algorithms, genetic algorithm (GA) and PSO are the two most used algorithms, and have been successfully used to optimize a variety of engineering problems. However, both of the algorithms have merits and demerits. Therefore, when considering the advantages of both the algorithms, a hybrid algorithm named PSO-GA is proposed to optimize the heliostat field layouts in this study.
From the literatures available, it is clear that the aspects of heliostat research mainly focus on codes to calculate heliostat field efficiency, methods to calculate the efficiency more accurate and faster, and optimization of heliostat field layouts. However, in the aspect of heliostat field optimization, most of the studies optimize the heliostat field using the heliostat field efficiency as the objective function. However, a heliostat field with higher efficiency does not indicate that the field has better economic performances. In our previous study [20], a heliostat field was optimized using a PSO-GA method to determine the highest potential daily energy collection. In this paper, the heliostat field is optimized on annual basis and ECUC is optimized as the objective function. Therefore, the aim of this paper is to optimize the heliostat field to obtain the highest possible ECUC using the PSO-GA method. Servicing this aim, the contents of this paper are: (1) Mathematical models of a heliostat field and PSO-GA are coded in Matlab; (2) A heliostat field in Lhasa is optimized to determine the highest possible annual ECUC; (3) Annual performances of optimized and un-optimized heliostat field are analyzed and compared, and effects of some key parameters on the heliostat field are also investigated.

2. Mathematical Model

Mathematical models of a circular heliostat field with a columnar receiver and a hybrid PSO-GA algorithm are coded in Matlab. The heliostat field model includes two main parts, a preliminary heliostat field generation and optical efficiency calculation. The basic parameters of a heliostat field are shown in Table 1 [12]. Based on our previous study [20], Nhel1 is set as 30.

2.1. A Preliminary Heliostat Field Generation

In this part, a radial staggered layout heliostat field is used. In this configuration, the heliostats are placed in rings around the central tower and the heliostats stand in between two heliostats of the ring in front, which can considerably reduce the shadowing and blocking influence [21]. The variables that are used to define the heliostat field layout are presented in Figure 1.
In Figure 1, DM is the distance between the center of two adjacent heliostats, and can be calculated by Equation (1) [22]:
DM = DH + desp = [ 1 + ( LW / LH ) 2 + x ] · LH
x is the optimization parameter, which can be used to control the azimuthal spacing between two adjoining heliostats.
The minimum radial increment can be obtained by [22]:
Δ R min DM · cos 30 °
To optimize the radial distance in different zones, an optimization parameter y i is introduced into Equation (7). Thus, the modified equation of radial distance is as follows:
Δ R i = y i · DM · cos 30 °   ( i = 1 ,   2 ,   3 )
The azimuth angular spacing between contiguous heliostats in the first zone, which remains the same, is defined as [22].
Δ α 1 = 2 × arcsin [ DM / 2 R 1 ] DM / R 1
The length of the azimuth spacing will gradually increase as the radius of the row increase in radial stagger configuration [11,21,23,24]. A new zone would be formed when an additional heliostat can be placed between neighboring heliostats in the same row. Thus, the azimuth angular spacing of the second zone ( Δ α 2 ) and the third zone ( Δ α 3 ) should be:
Δ α 2 = Δ α 1 / 2 = DM / R 2
Δ α 3 = Δ α 1 / 4 = DM / R 3
Moreover, the same radial distances in different zones, so the number of rows in different zones can be obtained by [22]:
Nrows 1 = round   [ ( R 2 R 1 ) / Δ R 1 ]
Nrows 2 = round   [ ( R 3 R 2 ) / Δ R 2 ]
Nrows 3 = round   [ ( R 4 R 3 ) / Δ R 3 ]
In Equations (7)–(9), round indicates that the quotient is rounded off to the next lower integer because Nrowsi is an integer. The number of heliostats in each row for the different zones can be obtained as follows [22]:
Nhel 1 = 2 π / Δ α 1 = 2 π R 1 / DM
Nhel 2 = 4 π R 1 / DM
Nhel 3 = 8 π R 1 / DM
Therefore, the number of heliostats of the heliostat field can be calculated by:
Num = Nrows i · Nhel i   ( i = 1 ,   2 ,   3 )
The land area of the heliostat field can be obtained by [25]:
Area = π ( R last + 0.5 DM ) 2

2.2. Optical Efficiency Calculation

Based on Sandia nomenclature, instantaneous optical efficiency of a heliostat is defined by [26]:
η ( x ,   y ,   t ) = ρ · cos ( x ,   y ,   t ) f at ( x ,   y ) f sb ( x ,   y ,   t ) f int ( x ,   y ,   t )
The cosine factor is the most influential optical factor on heliostats’ performance, which is the incidence cosine between the incident ray and the normal to the heliostat surface and can be calculated by the incident vector and the reflect vector.
The incident vector, which is pointing to the sun, can be gained by:
S = ( cos α sin β ,   cos α cos β , sin α )
α and β can be obtained as follows [27]:
α = arcsin ( cos φ cos δ cos ω + sin φ sin δ )
β = sgn ( ω ) | arccos ( ( sin α sin φ sin δ ) / ( cos α cos φ ) ) |
ω = 15 π ( t 12 ) / 180
δ = 23.45 π 180 sin ( 2 π 284 + n 365 )
The reflect vector, which is pointing to the receiver, can be obtained by the coordinates of the center of the heliostats and the receiver. Thus, cosine factor can be gained by:
cos = cos ( arccos ( S · R ) / 2 )
The atmospheric attenuation factor is another important factor, which calculates the beam losses of the reflected ray. Atmospheric attenuation factor depends on the distance between the heliostat and the receiver which can be obtained by [12]:
f at = { 0.99321 0.0001176 d hr + 1.97 × 10 8 d hr 2   d hr 1000   m exp ( 0.0001106 d hr )   d hr > 1000   m
The intercept factor is caused by tracking error, shape of sun, mirror aberrations, and mirror surface non-uniformity. In this study, the intercept factor is calculated by the HFLCAL model, which is a simpler and more accurate method when compared to the UNIZAR model [7]. This model considers that all of the heliostats are well-canted concentrating facets of spherical curvatures. The intercept factor can be calculated by:
f int = 1 2 π σ tot 2 x y exp ( x 2 + y 2 2 σ tot 2 ) dy dx
The shadowing loss happens when the incoming rays are obstructed by adjacent heliostats before they hit the problem heliostat. The blocking loss occurs when the reflected rays from the problem heliostat are blocked by adjacent heliostats before they reach the receiver. The shadowing and blocking factor is classified by the fraction of the heliostat area that is free of shadowing and blocking. Shadowing and blocking factor is related to the sun position during the day and the locations of the target heliostat and adjacent heliostats. Thus, the shadowing and blocking factor is the most complex and difficult factor to be calculated. In this study, the method that is used to calculate the shadowing and blocking factor is introduced in Refs. [22,28,29], which can not only save the calculation time but also ensure the accuracy of the calculation results. In this method, the projection shape of shadowing or blocking heliostat on the problem heliostat is assumed to be identical and parallel to the surface of the problem heliostat. Because of the radial staggered configuration, for blocking, only three heliostats are checked. As for shadowing, three other shadowing heliostats and former three blocking heliostats are checked.
The optical efficiency model has been validated in our previous work [20], and the results showed that our model developed in Matlab can be trusted for further analysis.

2.3. Annual Averaged Efficiency and Annual Energy Collected Per Unit Cost

In a real STPP, the heliostat field starts to work, when the solar altitude angle is higher than 15° and the DNI is higher than 150 W/m2 [30]. Therefore, the annual averaged efficiency of the heliostat field can be obtained by:
η annual = j = 1 365 i = 1 Num η hel , daily 365 × Num
In Equation (16), the daily averaged efficiency of a heliostat ( η hel , daily ) can be obtained by:
η hel , daily = t | DNI 150 , α 15 °   η dt t | DNI 150 , α 15 °   dt
Then, the daily energy collected can be obtained.
E = 0.0036 A h i = 1 Num DNI i 150 , α i 15 °   η DNI i
The annual energy collected can be calculated by:
E annual = i = 1 365 E i
The investment of the heliostat filed can be calculated by [31,32]:
I field = I col + I tower + I receiver + I land
I col = c col A h Num
I tower = 3 × 10 6 × exp   [ 0.0133   ( H tow RH 2 + H col 2 ) ]
I receiver = 55402800 ( 2 π · RH · RW 1110 ) 0.7
I land = c land ( 1.5 Area + 1.8 × 10 5 )
c col and c land are set to 126 USD/m2 and 0.62 USD/m2 [31].
Therefore, the annual ECUC can be obtained:
ECUC = E annual I field

2.4. Hybrid PSO-GA Algorithm

GA and PSO, two intelligent optimization algorithms, have been successfully applied in many optimization problems. GA is a computational model that is inspired by the natural selection and genetic mechanism of Darwin’s biological evolution theory. In GA, selection, crossover, and mutation are three of the most used genetic operations. Selection is a process where several individuals with higher fitness are selected from the whole population to breed a new generation. After selection, crossover, and mutation are applied to generate a new population from those selected individuals. Crossover is a process that two chosen parent individuals swap part of their genes to generate new individuals. Mutation alters one or more gene values in an individual, which can maintain genetic diversity from one generation to the next and the GA population can come to a better solution through mutation operation. PSO is originally inspired by the behavior of the birds’ cluster. As an optimization method, PSO is a population-based algorithm in which each particle updates its position and velocity vectors in each iteration by tracking its own previous best position (pbest) and group previous best position (gbest). In each iteration, each particle updates its velocity and position vectors according to the Equations (34)–(36).
v i ( t + 1 ) = m · v i ( t ) + c 1 r 1 ( pbest i ( t ) x i ( t ) ) + c 2 r 2 ( gbest i ( t ) x i ( t ) )
x i ( t + 1 ) = x i ( t ) + v i ( t + 1 )
m = { m min + ( m max m min ) ( fit fit min ) fit ave fit min   fit fit ave m max   fit > t ave
Each optimization algorithm has specific advantages and disadvantages. The idea of the hybrid algorithm can combine the merits of different optimization algorithm, but avoids their shortcomings [33]. Thus, hybrid optimization algorithms normally have a better optimization ability than one kind optimization algorithm alone. Similar to GA and PSO, the proposed PSO-GA is also a population-based optimization method. In this method, seven parameters m, c1, c2, r1, r2, Pc, and Pm are used to control the optimization process. m is the self-adaptive weight, which is used to control the algorithm capability of exploration based on the fitness of each particle in the previous generation population. In this study, m changes from 0.4 to 0.9. c1 and c2 are two acceleration coefficients, which are both set to 1.5. r1 and r2 are two random numbers distributed uniformly in the interval [0, 1]. Pc is the probability of crossover operation in the GA part of PSO-GA, which is set to 0.8. Pm is the probability of GA’s mutation operation in the GA part of PSO-GA, which is set to 0.3. In PSO-GA algorithm, first, a PSO population is randomly generated and pbest and gbest are determined according to the fitness of each particle. Next, the population is updated based on each particle’s position and velocity vectors. Then, crossover and mutation operations are implemented to update the particles in the population further. Then, fitness is recalculated, and pbest and gbest are updated. Finally, check the stop criteria, which is when the current generation reaches the maximum generation (MG) or the fitness of the population keeps constant for 50 iterations. The flow chart of the hybrid PSO-GA is shown in Figure 2.

3. Results and Discussion

In this study, in order to obtain the highest potential annual ECUC, the heliostat field located in Lhasa (29.67° N, 91.13° E) is optimized by the PSO-GA method. The yearly DNI distribution of Lhasa is derived from System Advisor Model (SAM) and is presented in Figure 3. In order to save optimization time, 12 special days in one year are used in the optimization process, which are recommended in Ref. [34] and listed in Table 2. The number of generations taken to reach the optimum result are listed in Table 3.

3.1. Optimized Results

Table 4 shows the optimized results of the heliostat field on annual basis. When compared with the un-optimized results, as can be seen from the table, the optimization parameters of radial distances in zones 1 and 2 are still equal to 1. While the optimization parameters of radial distance in zone 3 and the additional safety distance are bigger than those of the un-optimized results. The optimization parameters of radial distance in zone 3 and additional safety distance are 1.2971 and 0.0785, respectively. Therefore, the change of the optimization parameters of radial distance in zone 3 and the additional safety distance lead to the number of the heliostats decreasing from 3450 to 2850, but the heliostat field area increases from 1.10 × 106 m2 to 1.20 × 106 m2. After optimization, although the optimization parameters of radial distances in zones 1 and 2 are still equal to 1, the heliostat field efficiencies of zones 1 and 2 slightly increase from 0.6907 to 0.6924 and from 0.6281 to 6311, respectively. This is caused by the increase of the optimization parameter of the additional separation distance, which also influences Δ R 1 and Δ R 2 . What is more, the change of the optimization parameters of radial distance in zone 3 and additional safety distance causes the heliostat field efficiency in zone 3 increase from 0.4669 to 0.5339, nearly seven percentage points. As stated above, the efficiency of the heliostat field increases about six percentage points, which is mainly influenced by the increase of the heliostat field efficiency in zone 3. The increase of heliostat field efficiency and the decrease of heliostat number cause that Eannual decreases from 9.87 × 105 GJ to 9.08 × 105 GJ and ECUC increases from 12.50 MJ/USD to 12.97 MJ/USD, about 3.8% improvement. Figure 4 shows the change of the un-optimized and optimized heliostat field efficiencies per hour in a year. From the figure, the optimized efficiency is higher than the un-optimized efficiency. This is because, after optimization, the radial and angular distances between neighboring heliostats are bigger than these of un-optimized field, which cause the great improvement in shadowing and blocking factor. What is more, the variation tendencies of un-optimized and optimized heliostat field efficiencies are similar, which increase at first and then decrease.
The contours of the annual averaged efficiency of the heliostat field are shown in Figure 5. From the figure, the annual averaged efficiencies of north heliostat field are higher than these of the south heliostat field. After optimization, the radius of heliostat field increase from 583 m to 629 m, and the efficiency of the heliostat field is higher than that of the un-optimized field.

3.2. Sensitivity Analysis

In this study, the effects of Nhel1, tower height, and heliostat mirror collector cost have been explored.

3.2.1. Effect of Nhel1

The number of Nhel1 has an important influence on the heliostat field layout and the heliostat field optical efficiency. Therefore, the effects of Nhel1 on the heliostat field performances have been investigated, when the Nhel1 changes between 25 and 34, and the results are shown in Figure 6. As can be seen from Figure 6, the ECUC of the un-optimized heliostat field increase at first and then show a downward trend. When Nhel1 is 30, ECUC reaches the maximum value, about 12.45 MJ/USD. However, for the optimized heliostat field, ECUC shows an upward trend with the increase of Nhel1. When the Nhel1 increases from 25 to 34, ECUC grows up from 12.22 MJ/USD to 13.29 MJ/USD. What is more, the gap between un-optimized field and optimized field shows an upward trend with the increase of Nhel1 as well. The Eannual of optimized field is higher than the Eannual of un-optimized field when Nhel1 is 25. This is because the Num does not change after optimization, but the efficiency of the optimized field is higher that of the un-optimized field. While the values of Eannual of optimized field are higher than these of un-optimized field when Nhel1 changes from 28 to 34. This is caused by the change of Num and efficiency of the field.

3.2.2. Effect of Tower Height

Tower height has an important influence on the heliostat field layout and heliostat field optical efficiency as well. Therefore, the effects of tower height on heliostat field performances have been investigated, when the tower height changes between 130 m and 150 m, and the results are demonstrated in Figure 7. As can be seen from Figure 7, for both the un-optimized and optimized heliostat fields, ECUCs show an upward trend with the tower height. Nevertheless, the increase rate of the optimized field is lower than that of the un-optimized field. Therefore, the gap between the un-optimized field and optimized field gradually declines with the increase of tower height. For Eannual, the values of un-optimized and optimized heliostat field show an upward trend with tower height as well.

3.2.3. Effect of Heliostat Mirror Collector Cost

The cost of the heliostat mirror collector is an important factor in the heliostat field cost, which accounts for over 70% of the cost. Changing the cost of the heliostat mirror collector has an important influence on the performances of the heliostat field. In Ref. [35], it pointed out that the cost of the heliostat mirror is between 150 USD/m2 to 200 USD/m2 in 2013, and the cost will gradually decline and may reach 75 USD/m2 in the future. Thus, the effects of the cost of heliostat mirror collector on the heliostat field when the cost varies from 75 USD/m2 to 175 USD/m2 are discussed. The results are shown in Figure 8. As can be seen from Figure 8, for both the un-optimized and optimized heliostat fields, ECUCs show a downward trend with an increase of heliostat mirror collector cost. What is more, the gap between un-optimized heliostat field and optimized heliostat field gradually increases with the increase of heliostat mirror collector cost. The Eannual of un-optimized field does not change with the heliostat mirror collector cost. While the Eannual of optimized field decreases with the heliostat mirror collector cost, which is mainly caused by the Num in the heliostat field.

4. Conclusions

In this study, in order to optimize the heliostat field to obtain the highest annual ECUC, mathematical models of a heliostat field and PSO-GA are developed in Matlab and a heliostat field in Lhasa is analyzed as an example. Then, the effects of some key parameters on ECUC are also explored. When compared with the un-optimized results, the optimization parameters of radial distances in zones 1 and 2 are still equal to 1. While the optimization parameters of radial distance in zone 3 and additional safety distance are 1.2971 and 0.0785, respectively. After optimization, the annual efficiency of the heliostat field increases from 0.5074 to 0.5648, increased about 5.7%. What is more, the ECUC increases from 12.50 MJ/USD to 12.97 MJ/USD, increased about 3.8%. Studies on the key parameters show that: for un-optimized filed, ECUC first peaks and then declines with the increase of Nhel1. When the Nhel1 is 30, the heliostat field has the biggest ECUC. To the contrary, for optimized field, ECUC increases with Nhel1. What is more, for both un-optimized and optimized fields, ECUCs increase with tower height and decrease with the cost of heliostat mirror collector.

Acknowledgments

The research work is supported by National Major Fundamental Research Program of China (No. 2015CB251505), China National Natural Science Foundation (No. 51776063), Fundamental Research Funds for the Central Universities (2016XS29, 2016YQ04).

Author Contributions

All authors contributed to the paper. Chao Li and Rongrong Zhai carried out the simulations and performance analysis, and wrote the paper. Yongping Yang supervised the research and finalized the paper.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

Aharea of a heliostat, m2
Arealand area of the heliostat field, m2
c1 and c2acceleration coefficient
ccolunit cost of heliostat mirror collector, USD/m2
clandunit cost of land purchase, USD/m2
coscosine factor
DHdiagonal of heliostat, m
DMdistance between the center of two contiguous heliostats, m
DNIDirect Normal Irradiance, W/m2
Dgeneral dimension of the heliostat, m
despadditional separation distance, m
dhrdistance between the heliostat and the receiver, m
Edaily energy collected, MJ
Eannualannual energy collected, GJ
ECUCenergy collected of unit cost, MJ/USD
fatatmospheric attenuation factor
fintintercept factor
fsbshadowing and blocking factor
fitfitness of the calculated particle
GAgenetic algorithm
gbestbest solution found by the whole swarm
Hcolheliostat pedestal height, m
Htowtower height, m
Icolinvestment of heliostat mirror collector, USD
Ifieldinvestment of the heliostat field, USD
Ilandinvestment of land purchase, USD
Ireceiverinvestment of the receiver, USD
Itowerinvestment of the central tower, USD
LHheight of the heliostat, m
LWwidth of the heliostat, m
MGmaximum generation
mself-adaptive weight
Nhelinumber of heliostats in each row in the ith zone
Nrowsinumber of rows in the ith zone
Numnumber of heliostats of the heliostat field
nnumber of the calculating day in the year
pbestbest solution found by particle itself
PSOparticle swarm optimization algorithm
Rreflect vector
Riradius of the first row in the ith zone, m
Rlastradius of the last row in the third zone
RHreceiver height, m
RWreceiver radius, m
r1 and r2random number
Sincident vector
SPTTsolar tower power plant
tsolar time
vivelocity of the ith particle
xoptimization parameter of desp
xiposition of the ith particle
yioptimization parameter of radial distance in different zones
List of Greek Symbols
αaltitude angle of the sun, rad
βazimuth angle of the sun, rad
δsolar declination, rad
∆αiazimuthal spacing between adjacent heliostats in different zones, rad
∆Rminminimum radial increment, m
∆Riradial distance in the ith zone, m
ηinstantaneous optical efficiency of a heliostat
ηannualannual averaged efficiency of the heliostat field
ηhel,dailydaily averaged efficiency of a heliostat
ηzoneiannual averaged efficiency of the ith zone in the heliostat field
ωhour angle, rad
φlatitude of the location, °
ρreflectivity of the heliostat
σtottotal standard deviation of the incident ray on the receiver

References

  1. Ye, B.; Zhang, K.; Jiang, J.; Miao, L.; Li, J. Towards a 90% renewable energy future: A case study of an island in the South China Sea. Energy Convers. Manag. 2017, 142, 28–41. [Google Scholar] [CrossRef]
  2. Ye, B.; Yang, P.; Jiang, J.; Miao, L.; Shen, B.; Li, J. Feasibility and economic analysis of a renewable energy powered special town in China. Resour. Conserv. Recycl. 2017, 121, 40–50. [Google Scholar]
  3. Piroozmand, P.; Boroushaki, M. A computational method for optimal design of the multi-tower heliostat field considering heliostats interactions. Energy 2016, 106, 240–252. [Google Scholar]
  4. Emes, M.J.; Arjomandi, M.; Nathan, G.J. Effect of heliostat design wind speed on the levelised cost of electricity from concentrating solar thermal power tower plants. Sol. Energy 2015, 115, 441–451. [Google Scholar] [CrossRef]
  5. Zeyghami, M.; Khalili, F. Performance improvement of dry cooled advanced concentrating solar power plants using daytime radiative cooling. Energy Convers. Manag. 2015, 106, 10–20. [Google Scholar] [CrossRef]
  6. Reyes-Belmonte, M.A.; Sebastián, A.; Romero, M.; González-Aguilar, J. Optimization of a recompression supercritical carbon dioxide cycle for an innovative central receiver solar power plant. Energy 2016, 112, 17–27. [Google Scholar]
  7. Besarati, S.M.; Yogi Goswami, D. A computationally efficient method for the design of the heliostat field for solar power tower plant. Renew. Energy 2014, 69, 226–232. [Google Scholar] [CrossRef]
  8. Wei, X.; Lu, Z.; Wang, Z.; Yu, W.; Zhang, H.; Yao, Z. A new method for the design of the heliostat field layout for solar tower power plant. Renew. Energy 2010, 35, 1970–1975. [Google Scholar] [CrossRef]
  9. Schwarzbözl, P.; Schmitz, M.; Pitz-Paal, R. Visual HFLCAL—A Software Tool for Layout and Optimisation of Heliostat Fields. In Proceedings of the Solarpaces 2009, Berlin, Germany, 15–18 Septmeber 2009. [Google Scholar]
  10. Leary, P.L.; Hankins, J.D. User’s Guide for MIRVAL: A Computer Code for Comparing Designs of Heliostat-Receiver Optics for Central Receiver Solar Power Plants; Central Receivers; Sandia National Laboratories (SNL-CA): Livermore, CA, USA, 1979.
  11. Kistler, B.L. A user’s manual for DELSOL3: A computer code for calculating the optical performance and optimal system design for solar thermal central receiver plants. In Proceedings of the 3rd Central-European Workshop on Services and their Composition (ZEUS), Karlsruhe, Germany, 21–22 February 2011; pp. 24–25. [Google Scholar]
  12. Collado, F.J.; Guallar, J. A review of optimized design layouts for solar power tower plants with campo code. Renew. Sustain. Energy Rev. 2013, 20, 142–154. [Google Scholar] [CrossRef]
  13. Cádiz, P.; Frasquet, M.; Silva, M.; Martínez, F.; Carballo, J. Shadowing and blocking effect optimization for a variable geometry heliostat field. Energy Procedia 2015, 69, 60–69. [Google Scholar]
  14. Wei, X.; Lu, Z.; Yu, W.; Wang, Z. A new code for the design and analysis of the heliostat field layout for power tower system. Sol. Energy 2010, 84, 685–690. [Google Scholar] [CrossRef]
  15. Kim, S.; Lee, I.; Lee, B.J. Development of performance analysis model for central receiver system and its application to pattern-free heliostat layout optimization. Sol. Energy 2017, 153, 499–507. [Google Scholar] [CrossRef]
  16. Noone, C.J.; Torrilhon, M.; Mitsos, A. Heliostat field optimization: A new computationally efficient model and biomimetic layout. Sol. Energy 2012, 86, 792–803. [Google Scholar] [CrossRef]
  17. Gadalla, M.; Saghafifar, M. Thermo-economic and comparative analyses of two recently proposed optimization approaches for circular heliostat fields: Campo radial-staggered and biomimetic spiral. Sol. Energy 2016, 136, 197–209. [Google Scholar] [CrossRef]
  18. Eddhibi, F.; Ben Amara, M.; Balghouthi, M.; Guizani, A. Design and analysis of a heliostat field layout with reduced shading effect in southern Tunisia. Int. J. Hydrogen Energy 2017, 42, 28973–28996. [Google Scholar] [CrossRef]
  19. Zhang, M.; Yang, L.; Xu, C.; Du, X. An efficient code to optimize the heliostat field and comparisons between the biomimetic spiral and staggered layout. Renew. Energy 2016, 87, 720–730. [Google Scholar] [CrossRef]
  20. Li, C.; Zhai, R.; Liu, H.; Yang, Y.; Wu, H. Optimization of a heliostat field layout using hybrid PSO-GA algorithm. Appl. Therm. Eng. 2018, 128, 33–41. [Google Scholar] [CrossRef]
  21. Lipps, F.W. Theory of Cellwise Optimization for Solar Central Receiver System; No. SAND-85-8177; Houston University: Houston, TX, USA, 1985. [Google Scholar]
  22. Collado, F.J.; Guallar, J. Campo: Generation of regular heliostat fields. Renew. Energy 2012, 46, 49–59. [Google Scholar] [CrossRef]
  23. Lipps, F.W.; Vant-Hull, L.L. A cellwise method for the optimization of large central receiver systems. Sol. Energy 1978, 20, 505–516. [Google Scholar] [CrossRef]
  24. Lipps, F.W.; Vanthull, L.L. Shading and blocking geometry for a solar tower concentrator with rectangular mirrors. In Proceedings of the American Society of Mechanical Engineers, Winter Meeting, New York, NY, USA, 17–22 November 1974; pp. 57–58. [Google Scholar]
  25. Atif, M.; Al-Sulaiman, F.A. Development of a mathematical model for optimizing a heliostat field layout using differential evolution method. Int. J. Energy Res. 2015, 39, 1241–1255. [Google Scholar] [CrossRef]
  26. Saghafifar, M.; Gadalla, M. Thermo-economic analysis of air bottoming cycle hybridization using heliostat field collector: A comparative analysis. Energy 2016, 112, 698–714. [Google Scholar] [CrossRef]
  27. Duffie, J.A.; Beckman, W.A. Solar Engineering of Thermal Processes, 4th ed.; Wiley: Hoboken, NJ, USA, 2013. [Google Scholar]
  28. Collado, F.J. Design of solar tower plants heliostat by heliostat: The shadowing and blocking factor. In Proceedings of the Solarpaces 2011, Granada, Spain, 20–23 Septmeber 2011. [Google Scholar]
  29. Sassi, G. Some notes on shadow and blockage effects. Sol. Energy 1983, 31, 331–333. [Google Scholar] [CrossRef]
  30. Wagner, M.J. Simulation and Predictive Performance Modeling of Utility-Scale Central Receiver System Power Plants; University of Wisconsin: Madison, WI, USA, 2008. [Google Scholar]
  31. Saghafifar, M.; Gadalla, M. Thermo-economic optimization of hybrid solar Maisotsenko bottoming cycles using heliostat field collector: Comparative analysis. Appl. Energy 2017, 190, 686–702. [Google Scholar] [CrossRef]
  32. Modi, A.; Kærn, M.R.; Andreasen, J.G.; Haglind, F. Thermoeconomic optimization of a Kalina cycle for a central receiver concentrating solar power plant. Energy Convers. Manag. 2016, 115, 276–287. [Google Scholar] [CrossRef] [Green Version]
  33. Yu, S.; Zhang, J.; Zheng, S.; Sun, H. Provincial carbon intensity abatement potential estimation in China: A PSO–GA-optimized multi-factor environmental learning curve method. Energy Policy 2015, 77, 46–55. [Google Scholar] [CrossRef]
  34. Klein, S.A. Calculation of monthly average insolation on tilted surfaces. Sol. Energy 1977, 19, 325–329. [Google Scholar] [CrossRef]
  35. Pfahl, A.; Coventry, J.; Röger, M.; Wolfertstetter, F.; Vásquez-Arango, J.F.; Gross, F.; Arjomandi, M.; Schwarzbözl, P.; Geiger, M.; Liedke, P. Progress in heliostat development. Sol. Energy 2017, 152, 3–37. [Google Scholar] [CrossRef]
Figure 1. Fundamental definitions in the heliostat field.
Figure 1. Fundamental definitions in the heliostat field.
Energies 10 01924 g001
Figure 2. Flow chart of the hybrid particle swarm optimization (PSO)-genetic algorithm (GA).
Figure 2. Flow chart of the hybrid particle swarm optimization (PSO)-genetic algorithm (GA).
Energies 10 01924 g002
Figure 3. Yearly Direct Normal Irradiance (DNI) distribution of Lhasa.
Figure 3. Yearly Direct Normal Irradiance (DNI) distribution of Lhasa.
Energies 10 01924 g003
Figure 4. The heliostat field efficiency of the whole year.
Figure 4. The heliostat field efficiency of the whole year.
Energies 10 01924 g004
Figure 5. The contours of the annual averaged efficiency of heliostat field: (a) un-optimized result and (b) optimized result.
Figure 5. The contours of the annual averaged efficiency of heliostat field: (a) un-optimized result and (b) optimized result.
Energies 10 01924 g005
Figure 6. Effect of Nhel1 on the energy collected of unit cost and annual energy collected.
Figure 6. Effect of Nhel1 on the energy collected of unit cost and annual energy collected.
Energies 10 01924 g006
Figure 7. Effect of tower height on the energy collected of unit cost and annual energy collected.
Figure 7. Effect of tower height on the energy collected of unit cost and annual energy collected.
Energies 10 01924 g007
Figure 8. Effect of heliostat mirror collector cost on energy collected of unit cost and annual energy collected.
Figure 8. Effect of heliostat mirror collector cost on energy collected of unit cost and annual energy collected.
Energies 10 01924 g008
Table 1. Main parameters of heliostat used.
Table 1. Main parameters of heliostat used.
ParameterValueUnite
Tower optical height140m
Receiver radius4.0m
Receiver height9.0m
Heliostat total height9.752m
Heliostat total width12.305m
Heliostat pedestal height5m
Standard deviation surface error0.94mrad
Standard deviation tracking error0.63mrad
Standard deviation of sunshape2.51mrad
Effective reflectivity0.88 × 0.95-
Number of zones in the field3-
Number of heliostats in first row30-
Table 2. Recommended average days of month.
Table 2. Recommended average days of month.
MonthAverage Day of Month (Date)Day of the Year
January1717
February1647
March1675
April15105
May15135
June11162
July17198
August16228
September15258
October15288
November14318
December10344
Table 3. Number of generations taken to reach the optimum result.
Table 3. Number of generations taken to reach the optimum result.
Parameters Number of Generations
Nhel1 change25127
2882
30120
32111
3470
Tower height change130124
(m)135121
14575
150129
Heliostat mirror cost change7585
(USD/m2)100125
150147
175145
Table 4. Optimization results of the heliostat field on annual basis using PSO-GA algorithm.
Table 4. Optimization results of the heliostat field on annual basis using PSO-GA algorithm.
Un-Optimized FieldOptimized Field
y11.0000 1.0000
y21.0000 1.0000
y31.0000 1.2971
x0.0000 0.0785
Num34502850
Area (×106 m2)1.101.20
ηannual0.5074 0.5648
ηzone10.6907 0.6924
ηzone20.6281 0.6311
ηzone30.4669 0.5339
Eannual (×105 GJ) 9.879.08
ECUC (MJ/USD)12.50 12.97

Share and Cite

MDPI and ACS Style

Li, C.; Zhai, R.; Yang, Y. Optimization of a Heliostat Field Layout on Annual Basis Using a Hybrid Algorithm Combining Particle Swarm Optimization Algorithm and Genetic Algorithm. Energies 2017, 10, 1924. https://doi.org/10.3390/en10111924

AMA Style

Li C, Zhai R, Yang Y. Optimization of a Heliostat Field Layout on Annual Basis Using a Hybrid Algorithm Combining Particle Swarm Optimization Algorithm and Genetic Algorithm. Energies. 2017; 10(11):1924. https://doi.org/10.3390/en10111924

Chicago/Turabian Style

Li, Chao, Rongrong Zhai, and Yongping Yang. 2017. "Optimization of a Heliostat Field Layout on Annual Basis Using a Hybrid Algorithm Combining Particle Swarm Optimization Algorithm and Genetic Algorithm" Energies 10, no. 11: 1924. https://doi.org/10.3390/en10111924

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop