<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="en" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">101238455</journal-id>
<journal-title>International Journal of Environmental Research and Public Health</journal-title>
<issn pub-type="ppub">1661-7827</issn>
<issn pub-type="epub">1660-4601</issn>
<publisher>
<publisher-name>Molecular Diversity Preservation International (MDPI)</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3390/ijerph7083211</article-id>
<article-id pub-id-type="publisher-id">ijerph-07-03211</article-id>
<article-categories>
<subj-group>
<subject>Article</subject></subj-group></article-categories>
<title-group>
<article-title>Exploring Variation and Predictors of Residential Fine Particulate Matter Infiltration</article-title></title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Clark</surname><given-names>Nina A.</given-names></name><xref ref-type="aff" rid="af1-ijerph-07-03211">1</xref></contrib>
<contrib contrib-type="author">
<name><surname>Allen</surname><given-names>Ryan W.</given-names></name><xref ref-type="aff" rid="af2-ijerph-07-03211">2</xref></contrib>
<contrib contrib-type="author">
<name><surname>Hystad</surname><given-names>Perry</given-names></name><xref ref-type="aff" rid="af3-ijerph-07-03211">3</xref></contrib>
<contrib contrib-type="author">
<name><surname>Wallace</surname><given-names>Lance</given-names></name><xref ref-type="aff" rid="af4-ijerph-07-03211">4</xref></contrib>
<contrib contrib-type="author">
<name><surname>Dell</surname><given-names>Sharon D.</given-names></name><xref ref-type="aff" rid="af5-ijerph-07-03211">5</xref></contrib>
<contrib contrib-type="author">
<name><surname>Foty</surname><given-names>Richard</given-names></name><xref ref-type="aff" rid="af5-ijerph-07-03211">5</xref></contrib>
<contrib contrib-type="author">
<name><surname>Dabek-Zlotorzynska</surname><given-names>Ewa</given-names></name><xref ref-type="aff" rid="af6-ijerph-07-03211">6</xref></contrib>
<contrib contrib-type="author">
<name><surname>Evans</surname><given-names>Greg</given-names></name><xref ref-type="aff" rid="af7-ijerph-07-03211">7</xref></contrib>
<contrib contrib-type="author">
<name><surname>Wheeler</surname><given-names>Amanda J.</given-names></name><xref ref-type="aff" rid="af1-ijerph-07-03211">1</xref><xref ref-type="corresp" rid="c1-ijerph-07-03211">*</xref></contrib></contrib-group>
<aff id="af1-ijerph-07-03211">
<label>1</label> Health Canada, 269 Laurier Ave West, Ottawa, Ontario K1A 0K9, Canada; E-Mail: <email>nina.clark@hc-sc.gc.ca</email> (N.A.C.)</aff>
<aff id="af2-ijerph-07-03211">
<label>2</label> Simon Fraser University, 8888 University Drive, Burnaby, British Columbia V5A 1S6, Canada; E-Mail: <email>allenr@sfu.ca</email> (R.W.A.)</aff>
<aff id="af3-ijerph-07-03211">
<label>3</label> University of British Columbia, 2206 East Mall, Vancouver, British Columbia V6T 1Z3, Canada; E-Mail: <email>phystad@gmail.com</email> (P.H.)</aff>
<aff id="af4-ijerph-07-03211">
<label>4</label> 11568 Woodhollow Ct, Reston, VA 20191, USA; E-Mail: <email>lwallace73@gmail.com</email> (L.W.)</aff>
<aff id="af5-ijerph-07-03211">
<label>5</label> The Hospital for Sick Children, 555 University Avenue, Toronto, Ontario M5G 1X8, Canada; E-Mail: <email>sharon.dell@sickkids.ca</email> (S.D.D.); <email>richard.foty@sickkids.ca</email> (R.F.)</aff>
<aff id="af6-ijerph-07-03211">
<label>6</label> Environment Canada, 335 River Road, Ottawa, Ontario K1V 1C7, Canada; E-Mail: <email>Ewa.Dabek@ec.gc.ca</email> (E.D.-Z.)</aff>
<aff id="af7-ijerph-07-03211">
<label>7</label> University of Toronto, 200 College Street, Toronto, Ontario M5S 3E5, Canada; E-Mail: <email>greg.evans@utoronto.ca</email> (G.E)</aff>
<author-notes>
<corresp id="c1-ijerph-07-03211">
<label>*</label>Author to whom correspondence should be addressed; E-Mail: <email>amanda.wheeler@hc-sc.gc.ca</email>; Tel.: +1-613-948-3686; Fax: +1-613-948-8482.</corresp></author-notes>
<pub-date pub-type="ppub">
<month>8</month>
<year>2010</year></pub-date>
<pub-date pub-type="epub">
<day>16</day>
<month>8</month>
<year>2010</year></pub-date>
<volume>7</volume>
<issue>8</issue>
<fpage>3211</fpage>
<lpage>3224</lpage>
<history>
<date date-type="received">
<day>30</day>
<month>6</month>
<year>2010</year></date>
<date date-type="rev-recd">
<day>12</day>
<month>8</month>
<year>2010</year></date>
<date date-type="accepted">
<day>13</day>
<month>8</month>
<year>2010</year></date></history>
<permissions>
<copyright-statement>© 2010 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland.</copyright-statement>
<copyright-year>2010</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/3.0">
<p>This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).</p></license></permissions>
<abstract>
<p>Although individuals spend the majority of their time indoors, most epidemiological studies estimate personal air pollution exposures based on outdoor levels. This almost certainly results in exposure misclassification as pollutant infiltration varies between homes. However, it is often not possible to collect detailed measures of infiltration for individual homes in large-scale epidemiological studies and thus there is currently a need to develop models that can be used to predict these values. To address this need, we examined infiltration of fine particulate matter (PM<sub>2.5</sub>) and identified determinants of infiltration for 46 residential homes in Toronto, Canada. Infiltration was estimated using the indoor/outdoor sulphur ratio and information on hypothesized predictors of infiltration were collected using questionnaires and publicly available databases. Multiple linear regression was used to develop the models. Mean infiltration was 0.52 ± 0.21 with no significant difference across heating and non-heating seasons. Predictors of infiltration were air exchange, presence of central air conditioning, and forced air heating. These variables accounted for 38% of the variability in infiltration. Without air exchange, the model accounted for 26% of the variability. Effective modelling of infiltration in individual homes remains difficult, although key variables such as use of central air conditioning show potential as an easily attainable indicator of infiltration.</p></abstract>
<kwd-group>
<kwd>air exchange</kwd>
<kwd>air quality</kwd>
<kwd>indoor</kwd>
<kwd>infiltration</kwd>
<kwd>fine particulate matter</kwd>
<kwd>PM<sub>2.5</sub></kwd>
<kwd>residential</kwd>
<kwd>sulphur</kwd></kwd-group></article-meta></front>
<body>
<sec sec-type="intro">
<label>1.</label>
<title>Introduction</title>
<p>Exposure to outdoor particulate matter (PM) has been linked to a wide variety of health effects [<xref ref-type="bibr" rid="b1-ijerph-07-03211">1</xref>–<xref ref-type="bibr" rid="b3-ijerph-07-03211">3</xref>]. However, exposure assessment in epidemiological studies remains a challenge and misclassification limits the power of many studies to find true effects [<xref ref-type="bibr" rid="b4-ijerph-07-03211">4</xref>,<xref ref-type="bibr" rid="b5-ijerph-07-03211">5</xref>]. A nearly universal source of exposure misclassification in studies of outdoor air pollution results from estimating exposure based on outdoor levels alone. Indeed, individuals’ true exposures are determined by their time-activity patterns and levels of pollutants in each microenvironment where they spend time—typically indoors at home [<xref ref-type="bibr" rid="b6-ijerph-07-03211">6</xref>,<xref ref-type="bibr" rid="b7-ijerph-07-03211">7</xref>]. Surveys of activity patterns for Canada and the United States suggest that adults spend an average of about 88% of their time indoors, 66% of which is in their homes [<xref ref-type="bibr" rid="b8-ijerph-07-03211">8</xref>–<xref ref-type="bibr" rid="b10-ijerph-07-03211">10</xref>]. Exposure misclassification occurs because infiltration of outdoor pollution can vary significantly between residences and also within residences across time [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>–<xref ref-type="bibr" rid="b13-ijerph-07-03211">13</xref>].</p>
<p>There are important differences between indoor and outdoor PM composition in addition to differences in concentration. Outdoor generated PM contains relatively more sulphates, nitrates, strong acids, and toxic metals as compared with PM generated in homes, which contains more house dust, endotoxins, mold spores, and fresh combustion products [<xref ref-type="bibr" rid="b9-ijerph-07-03211">9</xref>]. Consequently, indoor and outdoor generated PM appear to have different health effects. Health effects of indoor PM<sub>2.5</sub> have not been thoroughly studied, but have been linked to respiratory problems [<xref ref-type="bibr" rid="b14-ijerph-07-03211">14</xref>–<xref ref-type="bibr" rid="b16-ijerph-07-03211">16</xref>]. Several studies that measured exposure to both indoor and outdoor PM<sub>2.5</sub> have found that outdoor-generated PM generally showed stronger relationships with respiratory [<xref ref-type="bibr" rid="b17-ijerph-07-03211">17</xref>–<xref ref-type="bibr" rid="b19-ijerph-07-03211">19</xref>] and cardiovascular [<xref ref-type="bibr" rid="b18-ijerph-07-03211">18</xref>] markers than total or indoor-generated PM<sub>2.5</sub> exposure. Therefore, differences in infiltration of outdoor generated PM<sub>2.5</sub> across homes could introduce exposure misclassification and may bias health effect estimates [<xref ref-type="bibr" rid="b20-ijerph-07-03211">20</xref>].</p>
<p>Infiltration differences across homes have the potential to cause differential misclassification, where the degree of misclassification depends on other variables in the analysis (such as disease status). For example, infiltration has been found to depend on characteristics that may also influence disease status, such as socioeconomic status [<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>,<xref ref-type="bibr" rid="b22-ijerph-07-03211">22</xref>]. Unlike non-differential misclassification, which generally causes a bias to the null, differential misclassification may cause unexpected effects in health effect estimates by causing a bias toward or away from the null [<xref ref-type="bibr" rid="b20-ijerph-07-03211">20</xref>].</p>
<p>The infiltration factor (F<sub>inf</sub>) is defined as the equilibrium proportion of outdoor PM that penetrates indoors and remains suspended [<xref ref-type="bibr" rid="b23-ijerph-07-03211">23</xref>]. This is determined by the particle penetration efficiency (<italic>P</italic>, unitless), particle deposition rate (<italic>k</italic>, h<sup>−1</sup>), and the air exchange rate (<italic>a</italic>, h<sup>−1</sup>) according to the following equation:
<disp-formula id="FD1">
<label>(1)</label>
<mml:math display="block">
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mtext>inf</mml:mtext></mml:mrow></mml:msub>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>P</mml:mi>
<mml:mi>a</mml:mi></mml:mrow>
<mml:mrow>
<mml:mi>a</mml:mi>
<mml:mo>+</mml:mo>
<mml:mi>k</mml:mi></mml:mrow></mml:mfrac></mml:math></disp-formula></p>
<p>Various studies have estimated F<sub>inf</sub> for residential homes. Most commonly they have employed sulphur or sulphate as a tracer of outdoor PM<sub>2.5</sub> [<xref ref-type="bibr" rid="b24-ijerph-07-03211">24</xref>–<xref ref-type="bibr" rid="b28-ijerph-07-03211">28</xref>], although indoor and outdoor measures of PM<sub>2.5</sub> have also commonly been used to estimate F<sub>inf</sub> [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>,<xref ref-type="bibr" rid="b13-ijerph-07-03211">13</xref>,<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>,<xref ref-type="bibr" rid="b29-ijerph-07-03211">29</xref>–<xref ref-type="bibr" rid="b31-ijerph-07-03211">31</xref>]. Sulphur has few indoor sources and has been demonstrated to be representative of total outdoor infiltrated PM<sub>2.5</sub> [<xref ref-type="bibr" rid="b9-ijerph-07-03211">9</xref>,<xref ref-type="bibr" rid="b32-ijerph-07-03211">32</xref>,<xref ref-type="bibr" rid="b33-ijerph-07-03211">33</xref>].</p>
<p>Though a number of studies have estimated F<sub>inf</sub> in individual homes and some panel studies have considered F<sub>inf</sub> in epidemiologic analyses [<xref ref-type="bibr" rid="b17-ijerph-07-03211">17</xref>–<xref ref-type="bibr" rid="b19-ijerph-07-03211">19</xref>], the need to include both indoor and outdoor pollution measurements to estimate F<sub>inf</sub> has prevented inclusion of infiltration in large-scale epidemiologic studies. The inclusion of infiltration ‘modification’ factors has been limited to air conditioning variables, such as community-wide prevalence of central air conditioning [<xref ref-type="bibr" rid="b34-ijerph-07-03211">34</xref>,<xref ref-type="bibr" rid="b35-ijerph-07-03211">35</xref>]. Given the importance of F<sub>inf</sub> (studies have shown F<sub>inf</sub> differences can modify indoor exposure rates by a magnitude of 2–4 [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>,<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>,<xref ref-type="bibr" rid="b24-ijerph-07-03211">24</xref>]), it is important to further examine how F<sub>inf</sub> varies between homes and what drives these differences. The goal of this study was to determine household factors that influence F<sub>inf</sub>, as indicated by the sulphur tracer method [<xref ref-type="bibr" rid="b27-ijerph-07-03211">27</xref>] for homes in Toronto, Ontario.</p></sec>
<sec>
<label>2.</label>
<title>Experimental Section</title>
<sec sec-type="methods">
<label>2.1.</label>
<title>Data Collection</title>
<p>Sixty homes from the Toronto area were recruited for the study. Homes were randomly selected from among 1,500 owner-occupied homes with secure backyards participating in the population-based Toronto Child Health Evaluation Questionnaire (T-CHEQ) study [<xref ref-type="bibr" rid="b36-ijerph-07-03211">36</xref>]. The T-CHEQ sample as a whole (n = 5,619) is representative of the population in terms of socioeconomic and housing variability as compared to the 2001 Canada census [<xref ref-type="bibr" rid="b36-ijerph-07-03211">36</xref>], however, the criteria of home-ownership with backyard biased the current study to a somewhat higher socioeconomic status. Fifty homes were initially recruited to participate in the indoor and outdoor sampling in 2006 (August to November) and an additional 10 homes were recruited to participate in 2007 (July).</p>
<p>Participating households completed a baseline questionnaire before sampling began. The questionnaire was a detailed home assessment, including variables that were anticipated to influence F<sub>inf</sub>: home age and size [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>,<xref ref-type="bibr" rid="b37-ijerph-07-03211">37</xref>], home value [<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>], heating and cooling systems used [<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>,<xref ref-type="bibr" rid="b24-ijerph-07-03211">24</xref>], presence of air filters [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>,<xref ref-type="bibr" rid="b17-ijerph-07-03211">17</xref>], presence of storm windows [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>,<xref ref-type="bibr" rid="b24-ijerph-07-03211">24</xref>], and number of residents and pets in the home (which have been observed to increase F<sub>inf</sub> due to increased air exchange) [<xref ref-type="bibr" rid="b37-ijerph-07-03211">37</xref>,<xref ref-type="bibr" rid="b38-ijerph-07-03211">38</xref>]. The assessment was completed by trained technicians along with the home owner during an inspection of the home. Unfortunately, it was not possible to collect information on activities in the home during sampling such as cooking, cleaning, window opening and air conditioner use.</p>
<p>Each home was sampled over a five-day period, with approximately 4 homes sampled concurrently. Most inspections began in the middle of the week and included weekdays and weekend days. Indoor measurements were collected at breathing height inside participants’ homes, typically in the family or living room where participants spent the majority of their time. When possible, measurements were collected away from ventilation ducts, fireplaces, and TVs as these may cause elevated concentrations of particles. Outdoor samplers were located in the backyard of the participants’ homes several meters away from the house and away from any combustion sources such as barbeques, automobiles and other localized outdoor sources of air pollution. The outdoor sampling height was approximately 1.5 meters above ground.</p>
<p>Indoor and outdoor PM<sub>2.5</sub> mass was sampled over the entire 5-day period using a Chempass Multi-Component Sampling System (Model 3400, R&amp;P/Thermo Scientific, Waltham, MA). The indoor and outdoor systems used a BGI pump with an AC adapter. The sampler target flow rate was 1.8 L/minute and flow rates more than 20% different from the target rate were considered invalid. Flow rates were assessed pre and post sampling using a soap bubble flow meter (AP Buck, Orlando, FL). The samples were collected on 37 mm Teflon™ filters, which were measured gravimetrically following US EPA quality assurance guidelines [<xref ref-type="bibr" rid="b39-ijerph-07-03211">39</xref>]. Briefly, filters were pre-conditioned for a minimum of 24 h before weighing at a constant air temperature of 21 <sup>o</sup>C (±0.5 <sup>o</sup>C) and constant relative humidity (RH) of 40% (±1%).</p>
<p>All samples were analyzed for total sulphur by a Panalytical Epilson 5 energy dispersive x-ray fluorescence (ED-XRF) spectrometer with a 600-watt gadolinium target tube as an excitation source. Micromatter® standard reference samples were used for the quantitative calibration of the system. A calibration check was performed by analyzing NIST standards (SRM1832 and SRM1833). Following the measurement process, data treatment was performed using complex algorithms that corrected for background signal, spectral interferences, and X-ray signal loss due to absorption by the sample mass. Blank filters were used for background subtraction. Typical analytical limits of detection and uncertainty were estimated to be 3.0 ng/cm<sup>2</sup> and 5%, respectively.</p>
<p>The indoor temperature and relative humidity were measured using HOBO Temperature Relative Humidity Data Logger (U10-003, Onset Corporation, Bourne, MA, USA) at three-minute time intervals. Outdoor meteorological data were obtained from the National Climate Data and Information Archive of Environment Canada [<xref ref-type="bibr" rid="b40-ijerph-07-03211">40</xref>].</p>
<p>Air exchange rate (AER) (the rate at which outdoor air replaces indoor air) was measured in the 50 homes monitored in 2006 using a perfluorocarbon tracer (PFT) source emitting a tracer at a constant rate. This was captured by a capillary adsorption tube (CAT), a passive sampler containing a small amount of activated charcoal adsorbing material [<xref ref-type="bibr" rid="b41-ijerph-07-03211">41</xref>]. Four PFTs were placed in the corners of the floor where the indoor equipment was located, and one CAT was placed near the center of the floor at head height. After exposure, the CAT was shipped to the lab and analyzed by gas chromatography with an electron capture detector (GC/ECD). Air exchange rate was then calculated using the concentration of PFT detected on the CAT and the volume of the home (estimated by multiplying square footage of the home by the technician’s estimate of ceiling height for the home). Air exchange was measured on the main living floor (in family or living room) only as this has been demonstrated to be a relatively accurate estimate of air exchange for the house: Wallace <italic>et al.</italic> [<xref ref-type="bibr" rid="b42-ijerph-07-03211">42</xref>] found inter-floor differences of less than 10% in a three-story home measured over a year. However, it was not possible to assess factors that may influence mixing of air in the home, such as closed doors. Closed doors to rooms or whole floors of the home for extended periods of time (e.g., nighttime) would reduce the effective volume of the home and thereby cause an underestimate of air exchange.</p>
<p>In addition to information collected during exposure monitoring, other variables of interest were collected from publicly available tax records [<xref ref-type="bibr" rid="b43-ijerph-07-03211">43</xref>] and geographic information system (GIS) data. Specifically, information was obtained on home size and market value from the Municipal Property Assessment Corporation (MPAC) of Ontario, as these factors have been observed to influence F<sub>inf</sub> [<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>,<xref ref-type="bibr" rid="b37-ijerph-07-03211">37</xref>]. GIS data were used to determine the distance of each home to the nearest highway. Roadway classifications in the CanMap RouteLogistics dataset were used, including highways and expressways (400 series highways and expressways).</p></sec>
<sec sec-type="methods">
<label>2.2.</label>
<title>Statistical Methods</title>
<p>Infiltration was calculated using the ratio of the indoor concentration and the outdoor concentration of sulphur (<xref ref-type="disp-formula" rid="FD2">Equation 2</xref>).</p>
<disp-formula id="FD2">
<label>(2)</label>
<mml:math display="block">
<mml:msubsup>
<mml:mi>F</mml:mi>
<mml:mrow>
<mml:mtext>inf</mml:mtext></mml:mrow>
<mml:mi>S</mml:mi></mml:msubsup>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mtext mathvariant="italic">in</mml:mtext></mml:mrow></mml:msub></mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>S</mml:mi>
<mml:mrow>
<mml:mtext mathvariant="italic">out</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:math></disp-formula>
<p>Linear regression was used to examine the association between housing and climatic variables and F<sub>inf</sub>. Right-skewed variables were log-normally transformed for regression modelling. Ambient temperature was examined as an effect modifier due to its influence on window opening behaviour, use of air conditioners and indoor/outdoor temperature differences. This was included as an interaction term indicating whether outdoor temperature was above or below 18 °C at time of monitoring. Many of the housing and climate characteristics are expected to be correlated and thus bivariate regressions may only indicate an indirect effect. However, variables without a direct effect may still be helpful for predicting F<sub>inf</sub> in studies with limited data, and are therefore presented along with multiple linear regression models.</p>
<p>To understand the best predictors of F<sub>inf</sub>, variables that were associated with F<sub>inf</sub> (p &lt; 0.10) in a simple linear regression were entered into multiple linear regression models. Two sets of models were examined: one set in which air exchange rate was a potential predictor variable and another set in which it was not, as this variable is often not available in larger-scale epidemiology studies. A stepwise procedure was used to select the most appropriate models, with p &lt; 0.10 as the cut-off for inclusion of variables. The guideline of a minimum of 10 observations per degree of freedom was followed to guard against over-fitting. Collinearity between variables was examined using Pearson and Spearman correlation coefficients and t-tests where appropriate, as well as using the “collin” option available for the REG procedure in SAS 9.1 (SAS Institute Inc., Cary, NC, USA).</p></sec></sec>
<sec sec-type="results">
<label>3.</label>
<title>Results</title>
<p><xref ref-type="table" rid="t1-ijerph-07-03211">Table 1</xref> provides descriptive data for F<sub>inf</sub>, pollutant measurements, and home and climate characteristics that were hypothesized <italic>a priori</italic> to have an effect on F<sub>inf</sub>. Of the 60 participating homes, 53 were analyzed for sulphur content indoors and outdoors. Of the calculated F<sub>inf</sub> values, two homes had an indoor/outdoor sulphur ratio greater than one (2.89 and 3.09) and likely indicate an undetected indoor source of sulphur, for example, an unreported humidifier in the home [<xref ref-type="bibr" rid="b9-ijerph-07-03211">9</xref>]. Only values of F<sub>inf</sub> between 0 and 1 are physically valid; therefore, these two homes were excluded from further statistical analysis. An additional five homes had a sulphur ratio &gt;0.90 (ranging from 0.93–0.98) without a correspondingly high air exchange rate; these homes were also excluded from further analysis, leaving a total of 46 homes for analysis. As compared with included homes, the excluded homes were more likely to have higher levels of indoor PM<sub>2.5</sub> (13.9 ±7.08 μg/m<sup>3</sup> <italic>vs.</italic> 8.17 ± 5.18 μg/m<sup>3</sup>, p-value = 0.01) and indoor sulphur (1.08 ±0.35 μg/m<sup>3</sup> <italic>vs.</italic> 0.46 ± 0.31 μg/m<sup>3</sup>, p &lt; 0.001) (consistent with having an indoor source). They did not differ with respect to other analyzed variables. Additional homes were excluded from specific analyses when covariate data was not available; this was most significant for air exchange which was not measured in the 10 homes sampled in 2007. The participating home-owners were of higher socioeconomic status as compared with the general Canadian population, but home values were representative of the Greater Toronto Area, where the average single-family home price is $435,064 [<xref ref-type="bibr" rid="b44-ijerph-07-03211">44</xref>].</p>
<p>The mean (±standard deviation) F<sub>inf</sub> among the 46 included homes was 0.52 ± 0.21, ranging from 0.08 to 0.88 with approximately normal distribution. Means were not significantly different based on whether homes were sampled during times when heating might occur: when the outdoor temperature was below 18 °C, the average F<sub>inf</sub> was 0.54 ± 0.22 as compared with 0.48 ± 0.21 when temperature was above 18 °C. This difference was not statistically significant (p = 0.34).</p>
<p>The mean sulphur concentration was 0.46 ± 0.31 μg/m<sup>3</sup> indoors and 0.76 ± 0.36 μg/m<sup>3</sup> outdoors. On average, PM<sub>2.5</sub> concentrations were slightly higher outdoors (9.72 ± 3.90 μg/m<sup>3</sup>) than indoors (8.17 ± 5.18 μg/m<sup>3</sup>).</p>
<p>The results of simple linear regression are presented in <xref ref-type="table" rid="t2-ijerph-07-03211">Table 2</xref>. Since the great majority of homes had air conditioners (96%), a smaller group of “regular users of air conditioning” was also defined: homes that reported using their air conditioner at least 30 days/year. This group consisted of 24 homes (52%). No other information on use of heating or cooling systems was available, including whether they were actually used during sampling.</p>
<p>In multiple linear regression modeling, air exchange rate, use of air conditioning more than 30 days/year, and having forced air heating remained as independent predictors of F<sub>inf</sub>, predicting 38% of variability (<xref ref-type="table" rid="t3-ijerph-07-03211">Table 3</xref>). Without air exchange, the model was able to predict 26% of variability.</p></sec>
<sec sec-type="discussion">
<label>4.</label>
<title>Discussion</title>
<p>Infiltration is rarely measured in studies of air pollution and health because it is generally not feasible to do so for a large number of homes. However, it is an important determinant of personal exposures to outdoor air pollution. Variability between and within homes can be significant, for example, Allen <italic>et al.</italic> [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>] and Wallace <italic>et al.</italic> [<xref ref-type="bibr" rid="b27-ijerph-07-03211">27</xref>] found approximately a three- to four-fold range in F<sub>inf</sub> estimates between individual homes, ranging from 0.24 to 1.00 and 0.26 to 0.87, respectively. Our estimates of F<sub>inf</sub> show a ten-fold difference across homes, ranging from 0.08 to 0.88. Simple measures of PM<sub>2.5</sub> concentrations inside the home are insufficient to address these differences in exposure, since recent work suggest that outdoor particulate matter may be more detrimental to health than particulate matter generated in homes [<xref ref-type="bibr" rid="b9-ijerph-07-03211">9</xref>,<xref ref-type="bibr" rid="b18-ijerph-07-03211">18</xref>]. However, activities in homes such as cooking have also been found to contribute significant amounts of potentially toxic PM [<xref ref-type="bibr" rid="b45-ijerph-07-03211">45</xref>]. Development of reliable and efficient methods for modelling infiltration among large populations is therefore an important goal for improving air pollution health studies.</p>
<p>Toronto experiences relatively hot summers (average daily highs of 27 °C in July) and cold winters (average daily lows of −11 °C in January) [<xref ref-type="bibr" rid="b46-ijerph-07-03211">46</xref>]. These temperatures necessitate ensuring that buildings are well sealed from outdoor air and typically homes in Canada use mechanical heating/cooling for occupant comfort. It is therefore expected that Toronto homes would have relatively low infiltration as compared with homes in more moderate climates. Indeed, the mean infiltration estimate of 0.52 for homes in Toronto is lower than generally observed in milder climates, such as 0.65 in Seattle [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>], 0.62 in Victoria, BC [<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>] (both averaged over heating and non-heating seasons) and 0.70 in Riverside, CA (measured in fall) [<xref ref-type="bibr" rid="b29-ijerph-07-03211">29</xref>]. Regions with similar temperature extremes to Toronto that have also conducted measurements across heating and non-heating seasons have found similar estimates: 0.45 and 0.55 in North Carolina [<xref ref-type="bibr" rid="b27-ijerph-07-03211">27</xref>,<xref ref-type="bibr" rid="b31-ijerph-07-03211">31</xref>]; and 0.59 in Helsinki [<xref ref-type="bibr" rid="b37-ijerph-07-03211">37</xref>].</p>
<p>Another seasonally important source of unexplained variability is likely to be window opening behaviour. Meng <italic>et al.</italic> [<xref ref-type="bibr" rid="b47-ijerph-07-03211">47</xref>] observed that infiltration was highest when outdoor temperatures were close to 20 °C and decreased at higher and lower temperatures, likely due to window opening. Open windows significantly increase air exchange rates (by an estimated 1.1 air changes per hour as measured by Wallace <italic>et al.</italic> 2002 [<xref ref-type="bibr" rid="b42-ijerph-07-03211">42</xref>]) and thereby also increased F<sub>inf</sub> [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>,<xref ref-type="bibr" rid="b42-ijerph-07-03211">42</xref>,<xref ref-type="bibr" rid="b48-ijerph-07-03211">48</xref>].</p>
<p>Regular use of air conditioning was a consistent predictor of infiltration, despite a lack of information on actual use during sampling. Homes that reported using air conditioning on more than 30 days per year had significantly lower infiltration than homes that either did not have air conditioning or used it less than 30 days per year. Air conditioned homes are expected to have lower infiltration due to being more tightly sealed as well as experiencing deposition resulting from the ventilation system. This has been demonstrated in a number of studies including Dockery and Spengler [<xref ref-type="bibr" rid="b24-ijerph-07-03211">24</xref>], Suh <italic>et al.</italic> [<xref ref-type="bibr" rid="b25-ijerph-07-03211">25</xref>], Long <italic>et al.</italic> [<xref ref-type="bibr" rid="b49-ijerph-07-03211">49</xref>], and Meng <italic>et al.</italic> [<xref ref-type="bibr" rid="b12-ijerph-07-03211">12</xref>,<xref ref-type="bibr" rid="b47-ijerph-07-03211">47</xref>]. In addition, epidemiological studies have found that air conditioning prevalence accounts for some of the variability observed in the health effects of particulate matter across different cities. Janssen <italic>et al.</italic> [<xref ref-type="bibr" rid="b35-ijerph-07-03211">35</xref>] and Medina-Ramon <italic>et al.</italic> [<xref ref-type="bibr" rid="b50-ijerph-07-03211">50</xref>] found that across cities in the US, higher prevalence of central air conditioning attenuated the acute effects of PM<sub>10</sub>. A meta-analysis of 19 studies of particulate matter in the US also found that mortality was modified by central air conditioning prevalence: mortality increased by 0.57% (95% CI: 0.39–0.74%) per 10 μg/m<sup>3</sup> increase in ambient PM<sub>10</sub> in communities with central air conditioning prevalence greater than 30% <italic>vs.</italic> 0.76% (0.54–0.98%) with prevalence less than 30% [<xref ref-type="bibr" rid="b51-ijerph-07-03211">51</xref>]. A recent study by Bell <italic>et al.</italic> [<xref ref-type="bibr" rid="b52-ijerph-07-03211">52</xref>] confirmed the findings of attenuating effects of central air conditioning use on cardiovascular and respiratory diseases as well as mortality. Differences in central air conditioning prevalence across communities accounted for 17% of the variability in cardiovascular hospitalizations.</p>
<p>Publicly available property assessment data from MPAC was of limited utility in predicting infiltration in these Toronto homes. Hystad <italic>et al.</italic> [<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>] also examined the usefulness of property assessment data in Seattle, WA and Victoria, BC for predicting infiltration and found that the value of the structure, also known as improved value, served as an effective surrogate for a number of other housing variables and predicted F<sub>inf</sub>. Homes with structure value below the median had 15% higher infiltration than homes above the median. However, total market value did not predict F<sub>inf</sub> in Seattle, nor did it in Toronto. Unlike data sources in BC and WA, MPAC does not separate the home value into structure value and land value, preventing further examination of this relationship.</p>
<p>Of the other variables obtained from MPAC, only presence of forced air heating predicted infiltration, accounting for 7% of the variability. Although presence of central air conditioning was available through MPAC, comparison with home owner report suggests that this variable is not well maintained in the database; of the 39 homes who reported having central air conditioning, only 24 were classified as such in the MPAC database. Therefore, questionnaire data was relied on to classify homes for air conditioning presence.</p>
<p>Home age has previously been found to influence infiltration, though inconsistently across different studies. This is not unexpected as different building methods influencing tightness of the homes differ across regions and over time, and may be altered by home renovations (such as updated windows and insulation). There was a significant linear relationship with older homes having higher infiltration, although this relationship did not remain significant in multivariate models. A trend of lower infiltration in newer homes was also observed by Lachenmyer and Hidy [<xref ref-type="bibr" rid="b30-ijerph-07-03211">30</xref>], Hanninen <italic>et al.</italic> [<xref ref-type="bibr" rid="b37-ijerph-07-03211">37</xref>], and Hystad <italic>et al.</italic> [<xref ref-type="bibr" rid="b21-ijerph-07-03211">21</xref>], while Allen <italic>et al.</italic> [<xref ref-type="bibr" rid="b11-ijerph-07-03211">11</xref>] found that older homes had lower infiltration in a sample of Seattle homes. No effect of home age was observed by Meng <italic>et al.</italic> [<xref ref-type="bibr" rid="b47-ijerph-07-03211">47</xref>].</p>
<p>Distance to expressways was not associated with F<sub>inf</sub>. It was hypothesized that homes near busy roads may have lower infiltration due to windows being closed to reduce noise, however it is important to note that only 5 (11%) of study homes were within 500 m of expressways and that previous research has shown simple distance-based metrics to be only moderate predictors of noise [<xref ref-type="bibr" rid="b53-ijerph-07-03211">53</xref>].</p></sec>
<sec sec-type="conclusions">
<label>5.</label>
<title>Conclusions</title>
<p>This study, as well as others, has found that a large portion of the variability in infiltration cannot be explained using housing and climate characteristics. While information on air conditioning use and outdoor temperature can serve as proxy measures of window opening, they do not capture many important factors, such as the number of open windows, the size of the opening(s), and the duration that windows are left open, which could influence infiltrating particles. These variables were unavailable for this study to be able to identify their contribution.</p>
<p>F<sub>inf</sub> estimates found in Toronto homes are comparable to previous estimates from similar climates and homes and confirm that typically there is a high degree of variation in infiltration across different homes. Exposure to outdoor pollution can be markedly different even for individuals living in close proximity and experiencing similar outdoor levels. Effective modelling of F<sub>inf</sub> in individual homes remains difficult, although key variables such as use of central air conditioning show potential as an easily attainable indicator of F<sub>inf</sub>. These are important considerations when investigating the health effects of air pollution in large epidemiological studies especially when considering providing guidance on high air pollution days to vulnerable populations.</p></sec></body>
<back>
<ack>
<p>The authors would like to acknowledge the generosity of the families who participated in this study and provided valuable data. We would like to thank Robin Coombs and Kelly Sabaliauskas for their careful data collection. Appreciation is expressed to Keith Van Ryswyk, Hongyu You and Ryan Kulka for their help with training and data management. The authors are grateful to Dave Stieb for his guidance and suggestions regarding the design of the study. The GIS data were kindly provided by Michael Jerrett, Bernie Beckerman and Ketan Shankardass. Thank you to David Mathieu for his assistance with the XRF analyses. Funding was provided by Health Canada under the Clean Air Regulatory Agenda.</p></ack>
<ref-list>
<title>References</title>
<ref id="b1-ijerph-07-03211"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pope</surname><given-names>C</given-names></name></person-group><article-title>Epidemiology of Fine Particulate Air Pollution and Human Health: Biologic Mechanisms and Who’s at Risk?</article-title><source>Environ. Health Perspect</source><year>2000</year><volume>108</volume><fpage>713</fpage><lpage>723</lpage><pub-id pub-id-type="pmid">10931790</pub-id></citation></ref>
<ref id="b2-ijerph-07-03211"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Peters</surname><given-names>A</given-names></name><name><surname>Dockery</surname><given-names>DW</given-names></name><name><surname>Muller</surname><given-names>JE</given-names></name><name><surname>Mittleman</surname><given-names>MA</given-names></name></person-group><article-title>Increased Particulate Air Pollution and the Triggering of Myocardial Infarction</article-title><source>Circulation</source><year>2001</year><volume>103</volume><fpage>2810</fpage><lpage>2815</lpage><pub-id pub-id-type="doi">10.1161/01.CIR.103.23.2810</pub-id><pub-id pub-id-type="pmid">11401937</pub-id></citation></ref>
<ref id="b3-ijerph-07-03211"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>McCreanor</surname><given-names>J</given-names></name><name><surname>Cullinan</surname><given-names>P</given-names></name><name><surname>Nieuwenhuijsen</surname><given-names>MJ</given-names></name><name><surname>Stewart-Evans</surname><given-names>J</given-names></name><name><surname>Malliarou</surname><given-names>E</given-names></name><name><surname>Jarup</surname><given-names>L</given-names></name><name><surname>Harrington</surname><given-names>R</given-names></name><name><surname>Svartengren</surname><given-names>M</given-names></name><name><surname>Han</surname><given-names>IK</given-names></name><name><surname>Ohman-Strickland</surname><given-names>P</given-names></name><etal/></person-group><article-title>Respiratory Effects of Exposure to Diesel Traffic in Persons with Asthma</article-title><source>N. Engl. J. Med</source><year>2007</year><volume>357</volume><fpage>2348</fpage><lpage>2358</lpage><pub-id pub-id-type="doi">10.1056/NEJMoa071535</pub-id><pub-id pub-id-type="pmid">18057337</pub-id></citation></ref>
<ref id="b4-ijerph-07-03211"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Shy</surname><given-names>CM</given-names></name><name><surname>Kleinbaum</surname><given-names>DG</given-names></name><name><surname>Morgenstern</surname><given-names>H</given-names></name></person-group><article-title>The Effect of Misclassification of Exposure Status in Epidemiological Studies of Air Pollution Health Effects</article-title><source>Bull. N. Y. Acad. Med</source><year>1978</year><volume>54</volume><fpage>1155</fpage><lpage>1165</lpage><pub-id pub-id-type="pmid">19312979</pub-id></citation></ref>
<ref id="b5-ijerph-07-03211"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Navidi</surname><given-names>W</given-names></name><name><surname>Lurmann</surname><given-names>F</given-names></name></person-group><article-title>Measurement Error in Air Pollution Exposure Assessment</article-title><source>J. Expo. Anal. Environ. Epidemiol</source><year>1995</year><volume>5</volume><fpage>111</fpage><lpage>124</lpage><pub-id pub-id-type="pmid">7492901</pub-id></citation></ref>
<ref id="b6-ijerph-07-03211"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nethery</surname><given-names>E</given-names></name><name><surname>Leckie</surname><given-names>SE</given-names></name><name><surname>Teschke</surname><given-names>K</given-names></name><name><surname>Brauer</surname><given-names>M</given-names></name></person-group><article-title>From Measures to Models: An Evaluation of Air Pollution Exposure Assessment for Epidemiologic Studies of Pregnant Women</article-title><source>Occup. Environ. Med</source><year>2008</year><volume>65</volume><fpage>579</fpage><lpage>586</lpage><pub-id pub-id-type="doi">10.1136/oem.2007.035337</pub-id><pub-id pub-id-type="pmid">18070798</pub-id></citation></ref>
<ref id="b7-ijerph-07-03211"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Spengler</surname><given-names>JD</given-names></name><name><surname>Treitman</surname><given-names>RD</given-names></name><name><surname>Tosteson</surname><given-names>TD</given-names></name><name><surname>Mage</surname><given-names>DT</given-names></name><name><surname>Soczek</surname><given-names>ML</given-names></name></person-group><article-title>Personal Exposures to Respirable Particulates and Implications for Air Pollution Epidemiology</article-title><source>Environ. Sci. Technol</source><year>1985</year><volume>19</volume><fpage>700</fpage><lpage>707</lpage><pub-id pub-id-type="doi">10.1021/es00138a008</pub-id><pub-id pub-id-type="pmid">22166030</pub-id></citation></ref>
<ref id="b8-ijerph-07-03211"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Leech</surname><given-names>JA</given-names></name><name><surname>Wilby</surname><given-names>K</given-names></name><name><surname>McMullen</surname><given-names>E</given-names></name><name><surname>Laporte</surname><given-names>K</given-names></name></person-group><article-title>The Canadian Human Activity Pattern Survey: Report of Methods and Population Surveyed</article-title><source>Chronic Dis. Can</source><year>1996</year><volume>17</volume><fpage>118</fpage><lpage>123</lpage><pub-id pub-id-type="pmid">9097012</pub-id></citation></ref>
<ref id="b9-ijerph-07-03211"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wilson</surname><given-names>WE</given-names></name><name><surname>Brauer</surname><given-names>M</given-names></name></person-group><article-title>Estimation of Ambient and Non-Ambient Components of Particulate Matter Exposure from a Personal Monitoring Panel Study</article-title><source>J. Expo. Sci. Env. Epid</source><year>2006</year><volume>16</volume><fpage>264</fpage><lpage>274</lpage><pub-id pub-id-type="doi">10.1038/sj.jes.7500483</pub-id></citation></ref>
<ref id="b10-ijerph-07-03211"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Klepeis</surname><given-names>NE</given-names></name><name><surname>Nelson</surname><given-names>WC</given-names></name><name><surname>Ott</surname><given-names>WR</given-names></name><name><surname>Robinson</surname><given-names>JP</given-names></name><name><surname>Tsang</surname><given-names>AM</given-names></name><name><surname>Switzer</surname><given-names>P</given-names></name><name><surname>Behar</surname><given-names>JV</given-names></name><name><surname>Hern</surname><given-names>SC</given-names></name><name><surname>Engelmann</surname><given-names>WH</given-names></name></person-group><article-title>The National Human Activity Pattern Survey (NHAPS): A Resource for Assessing Exposure to Environmental Pollutants</article-title><source>J. Expo. Anal. Environ. Epidemiol</source><year>2001</year><volume>11</volume><fpage>231</fpage><lpage>252</lpage><pub-id pub-id-type="doi">10.1038/sj.jea.7500165</pub-id><pub-id pub-id-type="pmid">11477521</pub-id></citation></ref>
<ref id="b11-ijerph-07-03211"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Allen</surname><given-names>R</given-names></name><name><surname>Larson</surname><given-names>T</given-names></name><name><surname>Sheppard</surname><given-names>L</given-names></name><name><surname>Wallace</surname><given-names>L</given-names></name><name><surname>Liu</surname><given-names>LJS</given-names></name></person-group><article-title>Use of Real-Time Light Scattering Data to Estimate the Contribution of Infiltrated and Indoor-Generated Particles to Indoor Air</article-title><source>Environ. Sci. Technol</source><year>2003</year><volume>37</volume><fpage>3484</fpage><lpage>3492</lpage><pub-id pub-id-type="doi">10.1021/es021007e</pub-id><pub-id pub-id-type="pmid">12953856</pub-id></citation></ref>
<ref id="b12-ijerph-07-03211"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meng</surname><given-names>QY</given-names></name><name><surname>Turpin</surname><given-names>BJ</given-names></name><name><surname>Polidori</surname><given-names>A</given-names></name><name><surname>Lee</surname><given-names>JH</given-names></name><name><surname>Weisel</surname><given-names>C</given-names></name><name><surname>Morandi</surname><given-names>M</given-names></name><name><surname>Colome</surname><given-names>S</given-names></name><name><surname>Stock</surname><given-names>T</given-names></name><name><surname>Winer</surname><given-names>A</given-names></name><name><surname>Zhang</surname><given-names>J</given-names></name></person-group><article-title>PM<sub>2.5</sub> of Ambient Origin: Estimates and Exposure Errors Relevant to PM Epidemiology</article-title><source>Environ. Sci. Technol</source><year>2005</year><volume>39</volume><fpage>5105</fpage><lpage>5112</lpage><pub-id pub-id-type="doi">10.1021/es048226f</pub-id><pub-id pub-id-type="pmid">16082937</pub-id></citation></ref>
<ref id="b13-ijerph-07-03211"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Long</surname><given-names>CM</given-names></name><name><surname>Suh</surname><given-names>HH</given-names></name><name><surname>Catalano</surname><given-names>PJ</given-names></name><name><surname>Koutrakis</surname><given-names>P</given-names></name></person-group><article-title>Using Time-and Size-Resolved Particulate Data to Quantify Indoor Penetration and Deposition Behavior</article-title><source>Environ. Sci. Technol</source><year>2001</year><volume>35</volume><fpage>2089</fpage><lpage>2099</lpage><pub-id pub-id-type="doi">10.1021/es001477d</pub-id><pub-id pub-id-type="pmid">11393992</pub-id></citation></ref>
<ref id="b14-ijerph-07-03211"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Schwarze</surname><given-names>P</given-names></name><name><surname>Ovrevik</surname><given-names>J</given-names></name><name><surname>Lag</surname><given-names>M</given-names></name><name><surname>Refsnes</surname><given-names>M</given-names></name><name><surname>Nafstad</surname><given-names>P</given-names></name><name><surname>Hetland</surname><given-names>R</given-names></name><name><surname>Dybing</surname><given-names>E</given-names></name></person-group><article-title>Particulate Matter Properties and Health Effects: Consistency of Epidemiological and Toxicological Studies</article-title><source>Hum. Exp. Toxicol</source><year>2006</year><volume>25</volume><fpage>559</fpage><lpage>579</lpage><pub-id pub-id-type="doi">10.1177/096032706072520</pub-id><pub-id pub-id-type="pmid">17165623</pub-id></citation></ref>
<ref id="b15-ijerph-07-03211"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Smit</surname><given-names>L</given-names></name><name><surname>Heederik</surname><given-names>D</given-names></name><name><surname>Doekes</surname><given-names>G</given-names></name><name><surname>Blom</surname><given-names>C</given-names></name><name><surname>van Zweden</surname><given-names>I</given-names></name><name><surname>Wouters</surname><given-names>I</given-names></name></person-group><article-title>Exposure-Response Analysis of Allergy and Respiratory Symptoms in Endotoxin-Exposed Adults</article-title><source>Eur. Respir. J</source><year>2008</year><volume>31</volume><fpage>1241</fpage><lpage>1248</lpage><pub-id pub-id-type="doi">10.1183/09031936.00090607</pub-id><pub-id pub-id-type="pmid">18256063</pub-id></citation></ref>
<ref id="b16-ijerph-07-03211"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mitchell</surname><given-names>CS</given-names></name><name><surname>Zhang</surname><given-names>JJ</given-names></name><name><surname>Sigsgaard</surname><given-names>T</given-names></name><name><surname>Jantunen</surname><given-names>M</given-names></name><name><surname>Lioy</surname><given-names>PJ</given-names></name><name><surname>Samson</surname><given-names>R</given-names></name><name><surname>Karol</surname><given-names>MH</given-names></name></person-group><article-title>Current State of the Science: Health Effects and Indoor Environmental Quality</article-title><source>Environ. Health Perspect</source><year>2007</year><volume>115</volume><fpage>958</fpage><lpage>964</lpage><pub-id pub-id-type="doi">10.1289/ehp.8987</pub-id><pub-id pub-id-type="pmid">17589607</pub-id></citation></ref>
<ref id="b17-ijerph-07-03211"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Koenig</surname><given-names>JQ</given-names></name><name><surname>Mar</surname><given-names>TF</given-names></name><name><surname>Allen</surname><given-names>RW</given-names></name><name><surname>Jansen</surname><given-names>K</given-names></name><name><surname>Lumley</surname><given-names>T</given-names></name><name><surname>Sullivan</surname><given-names>JH</given-names></name><name><surname>Trenga</surname><given-names>CA</given-names></name><name><surname>Larson</surname><given-names>TV</given-names></name><name><surname>Liu</surname><given-names>LJS</given-names></name></person-group><article-title>Pulmonary Effects of Indoor-and Outdoor-Generated Particles in Children with Asthma</article-title><source>Environ. Health Perspect</source><year>2005</year><volume>113</volume><fpage>499</fpage><lpage>503</lpage><pub-id pub-id-type="doi">10.1289/ehp.7511</pub-id><pub-id pub-id-type="pmid">15811822</pub-id></citation></ref>
<ref id="b18-ijerph-07-03211"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ebelt</surname><given-names>ST</given-names></name><name><surname>Wilson</surname><given-names>WE</given-names></name><name><surname>Brauer</surname><given-names>M</given-names></name></person-group><article-title>Exposure to Ambient and Nonambient Components of Particulate Matter: A Comparison of Health Effects</article-title><source>Epidemiology</source><year>2005</year><volume>16</volume><fpage>396</fpage><lpage>405</lpage><pub-id pub-id-type="doi">10.1097/01.ede.0000158918.57071.3e</pub-id><pub-id pub-id-type="pmid">15824557</pub-id></citation></ref>
<ref id="b19-ijerph-07-03211"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Allen</surname><given-names>RW</given-names></name></person-group><article-title>Changes in Lung Function and Airway Inflammation among Asthmatic Children Residing in a Woodsmoke-Impacted Urban Area</article-title><source>Inhal. Toxicol</source><year>2008</year><volume>20</volume><fpage>423</fpage><lpage>433</lpage><pub-id pub-id-type="doi">10.1080/08958370801903826</pub-id><pub-id pub-id-type="pmid">18302050</pub-id></citation></ref>
<ref id="b20-ijerph-07-03211"><label>20.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Rothman</surname><given-names>KJ</given-names></name><name><surname>Greenland</surname><given-names>S</given-names></name><name><surname>Lash</surname><given-names>TL</given-names></name></person-group><source>Modern Epidemiology</source><publisher-name>Lippincott Williams &amp; Wilkins</publisher-name><publisher-loc>Philadelphia, PA, USA</publisher-loc><year>2008</year></citation></ref>
<ref id="b21-ijerph-07-03211"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hystad</surname><given-names>PU</given-names></name><name><surname>Setton</surname><given-names>EM</given-names></name><name><surname>Allen</surname><given-names>RW</given-names></name><name><surname>Keller</surname><given-names>PC</given-names></name><name><surname>Brauer</surname><given-names>M</given-names></name></person-group><article-title>Modeling Residential Fine Particulate Matter Infiltration for Exposure Assessment</article-title><source>J. Expo. Sci. Env. Epid</source><year>2008</year><volume>19</volume><fpage>570</fpage><lpage>579</lpage></citation></ref>
<ref id="b22-ijerph-07-03211"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mielck</surname><given-names>A</given-names></name><name><surname>Reitmeir</surname><given-names>P</given-names></name><name><surname>Wjst</surname><given-names>M</given-names></name></person-group><article-title>Severity of Childhood Asthma by Socioeconomic Status</article-title><source>Int. J. Epidemiol</source><year>1996</year><volume>25</volume><fpage>388</fpage><lpage>393</lpage><pub-id pub-id-type="doi">10.1093/ije/25.2.388</pub-id><pub-id pub-id-type="pmid">9119565</pub-id></citation></ref>
<ref id="b23-ijerph-07-03211"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wilson</surname><given-names>WE</given-names></name><name><surname>Mage</surname><given-names>DT</given-names></name><name><surname>Grant</surname><given-names>LD</given-names></name></person-group><article-title>Estimating Separately Personal Exposure to Ambient and Nonambient Particulate Matter for Epidemiology and Risk Assessment: Why and How</article-title><source>J. Air Waste Manage. Assoc</source><year>2000</year><volume>50</volume><fpage>1167</fpage><lpage>1183</lpage><pub-id pub-id-type="doi">10.1080/10473289.2000.10464164</pub-id></citation></ref>
<ref id="b24-ijerph-07-03211"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dockery</surname><given-names>DW</given-names></name><name><surname>Spengler</surname><given-names>JD</given-names></name></person-group><article-title>Indoor-Outdoor Relationships of Respirable Sulfates and Particles</article-title><source>Atmos. Environ. (1967)</source><year>1981</year><volume>15</volume><fpage>335</fpage><lpage>343</lpage><pub-id pub-id-type="doi">10.1016/0004-6981(81)90036-6</pub-id></citation></ref>
<ref id="b25-ijerph-07-03211"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Suh</surname><given-names>HH</given-names></name><name><surname>Spengler</surname><given-names>JD</given-names></name><name><surname>Koutrakis</surname><given-names>P</given-names></name></person-group><article-title>Personal Exposures to Acid Aerosols and Ammonia</article-title><source>Environ. Sci. Technol</source><year>1992</year><volume>26</volume><fpage>2507</fpage><lpage>2517</lpage><pub-id pub-id-type="doi">10.1021/es00036a026</pub-id></citation></ref>
<ref id="b26-ijerph-07-03211"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Leaderer</surname><given-names>B</given-names></name><name><surname>Naeher</surname><given-names>L</given-names></name><name><surname>Jankun</surname><given-names>T</given-names></name><name><surname>Balenger</surname><given-names>K</given-names></name><name><surname>Holford</surname><given-names>T</given-names></name><name><surname>Toth</surname><given-names>C</given-names></name><name><surname>Sullivan</surname><given-names>J</given-names></name><name><surname>Wolfson</surname><given-names>J</given-names></name><name><surname>Koutrakis</surname><given-names>P</given-names></name></person-group><article-title>Indoor, Outdoor, and Regional Summer and Winter Concentrations of PM<sub>10</sub>, PM<sub>2.5</sub>, SO<sub>4</sub><sup>2−</sup>, H<sup>+</sup>, NH<sub>4</sub><sup>+</sup>, NO<sup>3−</sup>, NH<sub>3</sub>, and Nitrous Acid in Homes with and without Kerosene Space Heaters</article-title><source>Environ. Health Perspect</source><year>1999</year><volume>107</volume><fpage>223</fpage><lpage>231</lpage><pub-id pub-id-type="pmid">10064553</pub-id></citation></ref>
<ref id="b27-ijerph-07-03211"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wallace</surname><given-names>L</given-names></name><name><surname>Williams</surname><given-names>R</given-names></name></person-group><article-title>Use of Personal-Indoor-Outdoor Sulfur Concentrations to Estimate the Infiltration Factor and Outdoor Exposure Factor for Individual Homes and Persons</article-title><source>Environ. Sci. Technol</source><year>2005</year><volume>39</volume><fpage>1707</fpage><lpage>1714</lpage><pub-id pub-id-type="doi">10.1021/es049547u</pub-id><pub-id pub-id-type="pmid">15819228</pub-id></citation></ref>
<ref id="b28-ijerph-07-03211"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Molnár</surname><given-names>P</given-names></name><name><surname>Johannesson</surname><given-names>S</given-names></name><name><surname>Boman</surname><given-names>J</given-names></name><name><surname>Barregård</surname><given-names>L</given-names></name><name><surname>Sällsten</surname><given-names>G</given-names></name></person-group><article-title>Personal Exposures and Indoor, Residential Outdoor, and Urban Background Levels of Fine Particle Trace Elements in the General Population</article-title><source>J. Environ. Monitor</source><year>2006</year><volume>8</volume><fpage>543</fpage><lpage>551</lpage><pub-id pub-id-type="doi">10.1039/b600827e</pub-id></citation></ref>
<ref id="b29-ijerph-07-03211"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ozkaynak</surname><given-names>H</given-names></name><name><surname>Xue</surname><given-names>J</given-names></name><name><surname>Spengler</surname><given-names>J</given-names></name><name><surname>Wallace</surname><given-names>L</given-names></name><name><surname>Pellizzari</surname><given-names>E</given-names></name><name><surname>Jenkins</surname><given-names>P</given-names></name></person-group><article-title>Personal Exposure to Airborne Particles and Metals: Results from the Particle TEAM Study in Riverside, California</article-title><source>J. Expo. Anal. Environ. Epidemiol</source><year>1996</year><volume>6</volume><fpage>57</fpage><lpage>78</lpage><pub-id pub-id-type="pmid">8777374</pub-id></citation></ref>
<ref id="b30-ijerph-07-03211"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lachenmyer</surname><given-names>C</given-names></name><name><surname>Hidy</surname><given-names>G</given-names></name></person-group><article-title>Urban Measurements of Outdoor-Indoor PM<sub>2.5</sub> Concentrations and Personal Exposure in the Deep South. Part I. Pilot Study of Mass Concentrations for Nonsmoking Subjects</article-title><source>Aerosol Sci. Tech</source><year>2000</year><volume>32</volume><fpage>34</fpage><lpage>51</lpage><pub-id pub-id-type="doi">10.1080/027868200303911</pub-id></citation></ref>
<ref id="b31-ijerph-07-03211"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Williams</surname><given-names>R</given-names></name><name><surname>Suggs</surname><given-names>J</given-names></name><name><surname>Rea</surname><given-names>A</given-names></name><name><surname>Sheldon</surname><given-names>L</given-names></name><name><surname>Rodes</surname><given-names>C</given-names></name><name><surname>Thornburg</surname><given-names>J</given-names></name></person-group><article-title>The Research Triangle Park Particulate Matter Panel Study: Modeling Ambient Source Contribution to Personal and Residential PM Mass Concentrations</article-title><source>Atmos. Environ</source><year>2003</year><volume>37</volume><fpage>5365</fpage><lpage>5378</lpage><pub-id pub-id-type="doi">10.1016/j.atmosenv.2003.09.010</pub-id></citation></ref>
<ref id="b32-ijerph-07-03211"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sarnat</surname><given-names>JA</given-names></name><name><surname>Long</surname><given-names>CM</given-names></name><name><surname>Koutrakis</surname><given-names>P</given-names></name><name><surname>Coull</surname><given-names>BA</given-names></name><name><surname>Schwartz</surname><given-names>J</given-names></name><name><surname>Suh</surname><given-names>HH</given-names></name></person-group><article-title>Using Sulfur as a Tracer of Outdoor Fine Particulate Matter</article-title><source>Environ. Sci. Technol</source><year>2002</year><volume>36</volume><fpage>5305</fpage><lpage>5314</lpage><pub-id pub-id-type="doi">10.1021/es025796b</pub-id><pub-id pub-id-type="pmid">12521154</pub-id></citation></ref>
<ref id="b33-ijerph-07-03211"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Martuzevicius</surname><given-names>D</given-names></name><name><surname>Grinshpun</surname><given-names>SA</given-names></name><name><surname>Reponen</surname><given-names>T</given-names></name><name><surname>Górny</surname><given-names>RL</given-names></name><name><surname>Shukla</surname><given-names>R</given-names></name><name><surname>Lockey</surname><given-names>J</given-names></name><name><surname>Hu</surname><given-names>S</given-names></name><name><surname>McDonald</surname><given-names>R</given-names></name><name><surname>Biswas</surname><given-names>P</given-names></name><name><surname>Kliucininkas</surname><given-names>L</given-names></name></person-group><article-title>Spatial and Temporal Variations of PM<sub>2.5</sub> Concentration and Composition Throughout an Urban Area with High Freeway density—The Greater Cincinnati Study</article-title><source>Atmos. Environ</source><year>2004</year><volume>38</volume><fpage>1091</fpage><lpage>1105</lpage><pub-id pub-id-type="doi">10.1016/j.atmosenv.2003.11.015</pub-id><pub-id pub-id-type="pmid">18509517</pub-id></citation></ref>
<ref id="b34-ijerph-07-03211"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Franklin</surname><given-names>M</given-names></name><name><surname>Zeka</surname><given-names>A</given-names></name><name><surname>Schwartz</surname><given-names>J</given-names></name></person-group><article-title>Association between PM<sub>2.5</sub> and all-Cause and Specific-Cause Mortality in 27 US Communities</article-title><source>J. Expo. Sci. Env. Epid</source><year>2006</year><volume>17</volume><fpage>279</fpage><lpage>287</lpage></citation></ref>
<ref id="b35-ijerph-07-03211"><label>35.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Janssen</surname><given-names>NAH</given-names></name><name><surname>Schwartz</surname><given-names>J</given-names></name><name><surname>Zanobetti</surname><given-names>A</given-names></name><name><surname>Suh</surname><given-names>HH</given-names></name></person-group><article-title>Air Conditioning and Source-Specific Particles as Modifiers of the Effect of PM<sub>10</sub> on Hospital Admissions for Heart and Lung Disease</article-title><source>Environ. Health Perspect</source><year>2002</year><volume>110</volume><fpage>43</fpage><lpage>49</lpage><pub-id pub-id-type="doi">10.1289/ehp.02110s143</pub-id><pub-id pub-id-type="pmid">11834462</pub-id></citation></ref>
<ref id="b36-ijerph-07-03211"><label>36.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dell</surname><given-names>SD</given-names></name><name><surname>Foty</surname><given-names>RG</given-names></name><name><surname>Gilbert</surname><given-names>NL</given-names></name><name><surname>Jerret</surname><given-names>M</given-names></name><name><surname>To</surname><given-names>T</given-names></name><name><surname>Walter</surname><given-names>SD</given-names></name><name><surname>Stieb</surname><given-names>DM</given-names></name></person-group><article-title>Asthma and Allergic Disease Prevalence in a Diverse Sample of Toronto School Children: Results from the Toronto Child Health Evaluation Questionnaire (T-CHEQ) Study</article-title><source>Can. Respir. J</source><year>2010</year><volume>17</volume><fpage>e1</fpage><lpage>6</lpage><pub-id pub-id-type="pmid">20186360</pub-id></citation></ref>
<ref id="b37-ijerph-07-03211"><label>37.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hänninen</surname><given-names>O</given-names></name><name><surname>Lebret</surname><given-names>E</given-names></name><name><surname>Ilacqua</surname><given-names>V</given-names></name><name><surname>Katsouyanni</surname><given-names>K</given-names></name><name><surname>Künzli</surname><given-names>N</given-names></name><name><surname>Srám</surname><given-names>R</given-names></name><name><surname>Jantunen</surname><given-names>M</given-names></name></person-group><article-title>Infiltration of Ambient PM<sub>2.5</sub> and Levels of Indoor Generated Non-ETS PM<sub>2.5</sub> in Residences of Four European Cities</article-title><source>Atmos. Environ</source><year>2004</year><volume>38</volume><fpage>6411</fpage><lpage>6423</lpage><pub-id pub-id-type="doi">10.1016/j.atmosenv.2004.07.015</pub-id></citation></ref>
<ref id="b38-ijerph-07-03211"><label>38.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sarnat</surname><given-names>SE</given-names></name><name><surname>Coull</surname><given-names>BA</given-names></name><name><surname>Ruiz</surname><given-names>PA</given-names></name><name><surname>Koutrakis</surname><given-names>P</given-names></name><name><surname>Suh</surname><given-names>HH</given-names></name></person-group><article-title>The Influences of Ambient Particle Composition and Size on Particle Infiltration in Los Angeles, CA, Residences</article-title><source>J. Air Waste Manag. Assoc</source><year>2006</year><volume>56</volume><fpage>186</fpage><lpage>196</lpage><pub-id pub-id-type="doi">10.1080/10473289.2006.10464449</pub-id><pub-id pub-id-type="pmid">16568802</pub-id></citation></ref>
<ref id="b39-ijerph-07-03211"><label>39.</label><citation citation-type="web"><person-group person-group-type="author"><collab>Human Exposure and Atmospheric Sciences Division</collab></person-group><source>Monitoring PM<sub>2.5</sub> in Ambient Air Using Designated Reference or Class 1 Equivalent Methods, Quality Assurance Guidance Document 2.12</source><comment>Available online: <ext-link xlink:href="http://www.epa.gov/ttnamti1/files/ambient/pm25/qa/m212covd.pdf" ext-link-type="uri">http://www.epa.gov/ttnamti1/files/ambient/pm25/qa/m212covd.pdf</ext-link> (accessed on 1 July 2010)</comment></citation></ref>
<ref id="b40-ijerph-07-03211"><label>40.</label><citation citation-type="web"><person-group person-group-type="author"><collab>Environment Canada</collab></person-group><source>Canadian Daily Climate Data. 2008</source><comment>Available online: <ext-link xlink:href="http://www.climate.weatheroffice.gc.ca/climateData/canada_e.html" ext-link-type="uri">http://www.climate.weatheroffice.gc.ca/climateData/canada_e.html</ext-link> (accessed on 1 November 2009)</comment></citation></ref>
<ref id="b41-ijerph-07-03211"><label>41.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Dietz</surname><given-names>RN</given-names></name><name><surname>Goodrich</surname><given-names>RW</given-names></name><name><surname>Cote</surname><given-names>EA</given-names></name><name><surname>Wieser</surname><given-names>RF</given-names></name></person-group><article-title>Detailed Description and Performance of a Passive Perfluorocarbon Tracer System for Building Ventilation and Air Exchange Measurements</article-title><source>Measured Air Leakage of Buildings: A Symposium</source><publisher-name>American Society for Testing and Materials</publisher-name><publisher-loc>Ann Arbor, MI, USA</publisher-loc><year>1986</year><fpage>203</fpage></citation></ref>
<ref id="b42-ijerph-07-03211"><label>42.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wallace</surname><given-names>L</given-names></name><name><surname>Emmerich</surname><given-names>S</given-names></name><name><surname>Howard-Reed</surname><given-names>C</given-names></name></person-group><article-title>Continuous Measurements of Air Change Rates in an Occupied House for 1 Year: The Effect of Temperature, Wind, Fans, and Windows</article-title><source>J. Expo. Anal. Environ. Epidemiol</source><year>2002</year><volume>12</volume><fpage>296</fpage><lpage>306</lpage><pub-id pub-id-type="doi">10.1038/sj.jea.7500229</pub-id><pub-id pub-id-type="pmid">12087436</pub-id></citation></ref>
<ref id="b43-ijerph-07-03211"><label>43.</label><citation citation-type="web"><person-group person-group-type="author"><collab>MPAC</collab></person-group><source>PropertyLine. 2008</source><comment>Available online: <ext-link xlink:href="http://www.mpac.ca/pages_english/products_services/propertyline.asp" ext-link-type="uri">http://www.mpac.ca/pages_english/products_services/propertyline.asp</ext-link> (accessed on 1 November 2009)</comment></citation></ref>
<ref id="b44-ijerph-07-03211"><label>44.</label><citation citation-type="web"><person-group person-group-type="author"><collab>The Canadian Real Estate Association</collab></person-group><source>MLS Statistics</source><comment>Available online: <ext-link xlink:href="http://www.crea.ca/public/news_stats/statistics.htm" ext-link-type="uri">http://www.crea.ca/public/news_stats/statistics.htm</ext-link> (accessed on 1 July 2010)</comment></citation></ref>
<ref id="b45-ijerph-07-03211"><label>45.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Evans</surname><given-names>G</given-names></name><name><surname>Peers</surname><given-names>A</given-names></name><name><surname>Sabaliauskas</surname><given-names>K</given-names></name></person-group><article-title>Particle Dose Estimation from Frying in Residential Settings</article-title><source>Indoor Air</source><year>2008</year><volume>18</volume><fpage>499</fpage><lpage>510</lpage><pub-id pub-id-type="doi">10.1111/j.1600-0668.2008.00551.x</pub-id><pub-id pub-id-type="pmid">19120500</pub-id></citation></ref>
<ref id="b46-ijerph-07-03211"><label>46.</label><citation citation-type="web"><person-group person-group-type="author"><collab>Environment Canada</collab></person-group><source>Canadian Climate Normals or Averages 1971–2000</source><comment>Available online: <ext-link xlink:href="http://www.climate.weatheroffice.gc.ca/climate_normals/index_e.html" ext-link-type="uri">http://www.climate.weatheroffice.gc.ca/climate_normals/index_e.html</ext-link> (accessed on 1 May 2010)</comment></citation></ref>
<ref id="b47-ijerph-07-03211"><label>47.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Meng</surname><given-names>Q</given-names></name><name><surname>Spector</surname><given-names>D</given-names></name><name><surname>Colome</surname><given-names>S</given-names></name><name><surname>Turpin</surname><given-names>B</given-names></name></person-group><article-title>Determinants of Indoor and Personal Exposure to PM<sub>2.5</sub> of Indoor and Outdoor Origin during the RIOPA Study</article-title><source>Atmos. Environ</source><year>2009</year><volume>43</volume><fpage>5750</fpage><lpage>5758</lpage><pub-id pub-id-type="doi">10.1016/j.atmosenv.2009.07.066</pub-id><pub-id pub-id-type="pmid">20339526</pub-id></citation></ref>
<ref id="b48-ijerph-07-03211"><label>48.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Howard-Reed</surname><given-names>C</given-names></name><name><surname>Wallace</surname><given-names>LA</given-names></name><name><surname>Ott</surname><given-names>WR</given-names></name></person-group><article-title>The Effect of Opening Windows on Air Change Rates in Two Homes</article-title><source>J. Air Waste Manag. Assoc</source><year>2002</year><volume>52</volume><fpage>147</fpage><lpage>159</lpage><pub-id pub-id-type="doi">10.1080/10473289.2002.10470775</pub-id><pub-id pub-id-type="pmid">15143789</pub-id></citation></ref>
<ref id="b49-ijerph-07-03211"><label>49.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Long</surname><given-names>CM</given-names></name><name><surname>Sarnat</surname><given-names>JA</given-names></name></person-group><article-title>Indoor-Outdoor Relationships and Infiltration Behavior of Elemental Components of Outdoor PM <sub>2.5</sub> for Boston-Area Homes</article-title><source>Aerosol Sci. Tech</source><year>2004</year><volume>38</volume><fpage>91</fpage><lpage>104</lpage></citation></ref>
<ref id="b50-ijerph-07-03211"><label>50.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Medina-Ramon</surname><given-names>M</given-names></name><name><surname>Zanobetti</surname><given-names>A</given-names></name><name><surname>Schwartz</surname><given-names>J</given-names></name></person-group><article-title>The Effect of Ozone and PM<sub>10</sub> on Hospital Admissions for Pneumonia and Chronic Obstructive Pulmonary Disease: A National Multicity Study</article-title><source>Am. J. Epidemiol</source><year>2006</year><volume>163</volume><fpage>579</fpage><lpage>588</lpage><pub-id pub-id-type="doi">10.1093/aje/kwj078</pub-id><pub-id pub-id-type="pmid">16443803</pub-id></citation></ref>
<ref id="b51-ijerph-07-03211"><label>51.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Levy</surname><given-names>J</given-names></name><name><surname>Hammitt</surname><given-names>J</given-names></name><name><surname>Spengler</surname><given-names>J</given-names></name></person-group><article-title>Estimating the Mortality Impacts of Particulate Matter: What Can Be Learned from Between-Study Variability?</article-title><source>Environ. Health Perspect</source><year>2000</year><volume>108</volume><fpage>109</fpage><lpage>117</lpage><pub-id pub-id-type="doi">10.1289/ehp.00108109</pub-id><pub-id pub-id-type="pmid">10656850</pub-id></citation></ref>
<ref id="b52-ijerph-07-03211"><label>52.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bell</surname><given-names>ML</given-names></name><name><surname>Ebisu</surname><given-names>K</given-names></name><name><surname>Peng</surname><given-names>RD</given-names></name><name><surname>Dominici</surname><given-names>F</given-names></name></person-group><article-title>Adverse Health Effects of Particulate Air Pollution: Modification by Air Conditioning</article-title><source>Epidemiology</source><year>2009</year><volume>20</volume><fpage>682</fpage><lpage>686</lpage><pub-id pub-id-type="doi">10.1097/EDE.0b013e3181aba749</pub-id><pub-id pub-id-type="pmid">19535984</pub-id></citation></ref>
<ref id="b53-ijerph-07-03211"><label>53.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Allen</surname><given-names>RW</given-names></name><name><surname>Davies</surname><given-names>H</given-names></name><name><surname>Cohen</surname><given-names>MA</given-names></name><name><surname>Mallach</surname><given-names>G</given-names></name><name><surname>Kaufman</surname><given-names>JD</given-names></name><name><surname>Adar</surname><given-names>SD</given-names></name></person-group><article-title>The Spatial Relationship between Traffic-Generated Air Pollution and Noise in 2 US Cities</article-title><source>Environ. Res</source><year>2009</year><volume>109</volume><fpage>334</fpage><lpage>342</lpage><pub-id pub-id-type="doi">10.1016/j.envres.2008.12.006</pub-id><pub-id pub-id-type="pmid">19193368</pub-id></citation></ref></ref-list>
<sec sec-type="display-objects">
<title>Tables</title>
<table-wrap id="t1-ijerph-07-03211" position="float">
<label>Table 1.</label>
<caption>
<p>Baseline and measured characteristics of 46 homes in Toronto. For household characteristics that were not obtained via questionnaire, the data source is indicated in brackets.</p></caption>
<table frame="box" rules="rows">
<thead>
<tr>
<th align="left" valign="top"><bold>Measurement Characteristics</bold></th>
<th align="center" valign="top"><bold>Total N</bold></th>
<th align="center" valign="top"><bold>Mean (standard deviation)</bold></th></tr></thead>
<tbody>
<tr>
<td align="left" valign="top">Finf</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">0.52 ± 0.21</td></tr>
<tr>
<td align="left" valign="top">PM<sub>2.5</sub> indoors</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">8.17 ± 5.18 μg/m<sup>3</sup></td></tr>
<tr>
<td align="left" valign="top">PM<sub>2.5</sub> outdoors</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">9.72 ± 3.90 μg/m<sup>3</sup></td></tr>
<tr>
<td align="left" valign="top">Sulphur indoors</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">0.46 ± 0.31 μg/m<sup>3</sup></td></tr>
<tr>
<td align="left" valign="top">Sulphur outdoors</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">0.76 ± 0.36 μg/m<sup>3</sup></td></tr>
<tr>
<td align="left" valign="top">Air exchange</td>
<td align="center" valign="top">35</td>
<td align="center" valign="top">0.22 ± 0.15/h</td></tr>
<tr>
<td align="left" valign="top">Indoor temperature</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">22.0 ± 2.1 °C</td></tr>
<tr>
<td align="left" valign="top">Indoor relative humidity</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">52.0 ± 7.5 %</td></tr>
<tr>
<td align="left" valign="top">Outdoor temperature</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">14.6 ± 6.2 °C</td></tr>
<tr>
<td align="left" valign="top">Outdoor relative humidity</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">72.6 ±7.7%</td></tr>
<tr>
<td align="left" valign="top"><bold>Household Characteristics</bold></td><td align="center" valign="top"/>
<td align="center" valign="top"><bold>Median (quartile range)</bold></td></tr>
<tr>
<td align="left" valign="top">Number of people in the home</td>
<td align="center" valign="top">44</td>
<td align="center" valign="top">4 (4–5)</td></tr>
<tr>
<td align="left" valign="top">Year home built (MPAC)</td>
<td align="center" valign="top">44</td>
<td align="center" valign="top">1948 (1925–1967)</td></tr>
<tr>
<td align="left" valign="top">Market value of home (MPAC)</td>
<td align="center" valign="top">44</td>
<td align="center" valign="top">$437,000 ($330,000–558,000)</td></tr>
<tr>
<td align="left" valign="top">Distance to expressway (GIS)</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">1.85 km (1.3–2.6 km)</td></tr>
<tr><td align="left" valign="top"/><td align="center" valign="top"/>
<td align="center" valign="top"><bold>Frequency (percentage)</bold></td></tr>
<tr>
<td align="left" valign="top">Forced air heating (MPAC)</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">33 (72%)</td></tr>
<tr>
<td align="left" valign="top">Have air conditioner (central or window unit)</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">44 (96%)</td></tr>
<tr>
<td align="left" valign="top">Have central air conditioner</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">39 (85%)</td></tr>
<tr>
<td align="left" valign="top">Use air conditioning &gt; 30 days/year</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">24 (52%)</td></tr>
<tr>
<td align="left" valign="top">Wood burning fireplace</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">20 (43%)</td></tr>
<tr>
<td align="left" valign="top">Air cleaning filter on furnace</td>
<td align="center" valign="top">45</td>
<td align="center" valign="top">34 (76%)</td></tr>
<tr>
<td align="left" valign="top">Premium air cleaning filter on furnace</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">16 (36%)</td></tr>
<tr>
<td align="left" valign="top">Dog or cat in the home</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">17 (37%)</td></tr>
<tr>
<td align="left" valign="top">Storm windows</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">10 (22%)</td></tr></tbody></table></table-wrap>
<table-wrap id="t2-ijerph-07-03211" position="float">
<label>Table 2.</label>
<caption>
<p>Simple linear regression of infiltration (F<sub>inf</sub>) with housing and climate characteristics predicted to influence F<sub>inf</sub>. Bold indicates regression with a p-value under 0.10.</p></caption>
<table frame="box" rules="rows">
<thead>
<tr>
<th align="left" valign="middle">Independent Variable</th>
<th align="center" valign="middle">N</th>
<th align="center" valign="middle">Regression Coefficient</th>
<th align="center" valign="middle">p-value</th>
<th align="center" valign="middle">Standard Error</th>
<th align="center" valign="middle">R<sup>2</sup></th></tr></thead>
<tbody>
<tr>
<td align="left" valign="top"><bold>Ln of Air exchange</bold></td>
<td align="center" valign="top"><bold>35</bold></td>
<td align="center" valign="top"><bold>0.139</bold></td>
<td align="center" valign="top"><bold>0.003</bold></td>
<td align="center" valign="top"><bold>0.043</bold></td>
<td align="center" valign="top"><bold>0.24</bold></td></tr>
<tr>
<td align="left" valign="top">Absolute temperature difference between indoors and outdoors (°C)</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">−0.003</td>
<td align="center" valign="top">0.699</td>
<td align="center" valign="top">0.007</td>
<td align="center" valign="top">0.00</td></tr>
<tr>
<td align="left" valign="top">Number of people in the home</td>
<td align="center" valign="top">44</td>
<td align="center" valign="top">0.003</td>
<td align="center" valign="top">0.933</td>
<td align="center" valign="top">0.037</td>
<td align="center" valign="top">0.00</td></tr>
<tr>
<td align="left" valign="top"><bold>Year home built</bold></td>
<td align="center" valign="top"><bold>44</bold></td>
<td align="center" valign="top"><bold>−0.003</bold></td>
<td align="center" valign="top"><bold>0.011</bold></td>
<td align="center" valign="top"><bold>0.001</bold></td>
<td align="center" valign="top"><bold>0.14</bold></td></tr>
<tr>
<td align="left" valign="top">Market value of home ($100,000)</td>
<td align="center" valign="top">44</td>
<td align="center" valign="top">−0.002</td>
<td align="center" valign="top">0.849</td>
<td align="center" valign="top">0.012</td>
<td align="center" valign="top">0.00</td></tr>
<tr>
<td align="left" valign="top">Distance to expressway (km)</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">0.023</td>
<td align="center" valign="top">0.381</td>
<td align="center" valign="top">0.026</td>
<td align="center" valign="top">0.02</td></tr>
<tr>
<td align="left" valign="top"><bold>Use air conditioning &gt;30 days/year</bold></td>
<td align="center" valign="top"><bold>46</bold></td>
<td align="center" valign="top"><bold>−0.201</bold></td>
<td align="center" valign="top"><bold>0.001</bold></td>
<td align="center" valign="top"><bold>0.056</bold></td>
<td align="center" valign="top"><bold>0.23</bold></td></tr>
<tr>
<td align="left" valign="top"><bold>Forced air heating (0/1)</bold></td>
<td align="center" valign="top"><bold>46</bold></td>
<td align="center" valign="top"><bold>−0.130</bold></td>
<td align="center" valign="top"><bold>0.078</bold></td>
<td align="center" valign="top"><bold>0.072</bold></td>
<td align="center" valign="top"><bold>0.07</bold></td></tr>
<tr>
<td align="left" valign="top"><bold>Wood burning fireplace (0/1)</bold></td>
<td align="center" valign="top"><bold>46</bold></td>
<td align="center" valign="top"><bold>0.120</bold></td>
<td align="center" valign="top"><bold>0.056</bold></td>
<td align="center" valign="top"><bold>0.061</bold></td>
<td align="center" valign="top"><bold>0.08</bold></td></tr>
<tr>
<td align="left" valign="top">Air cleaning filter on furnace (0/1)</td>
<td align="center" valign="top">45</td>
<td align="center" valign="top">−0.097</td>
<td align="center" valign="top">0.198</td>
<td align="center" valign="top">0.074</td>
<td align="center" valign="top">0.04</td></tr>
<tr>
<td align="left" valign="top">Premium filter on furnace (0/1)</td>
<td align="center" valign="top">45</td>
<td align="center" valign="top">0.083</td>
<td align="center" valign="top">0.218</td>
<td align="center" valign="top">0.067</td>
<td align="center" valign="top">0.04</td></tr>
<tr>
<td align="left" valign="top">Dog or cat in the home (0/1)</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">0.029</td>
<td align="center" valign="top">0.656</td>
<td align="center" valign="top">0.066</td>
<td align="center" valign="top">0.00</td></tr>
<tr>
<td align="left" valign="top">Storm windows (0/1)</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">0.121</td>
<td align="center" valign="top">0.113</td>
<td align="center" valign="top">0.075</td>
<td align="center" valign="top">0.06</td></tr></tbody></table></table-wrap>
<table-wrap id="t3-ijerph-07-03211" position="float">
<label>Table 3.</label>
<caption>
<p>Multivariate models predicting infiltration factor (F<sub>inf</sub>) using climate and housing characteristics.</p></caption>
<table frame="box" rules="all">
<thead>
<tr>
<th align="center" valign="middle"><bold>Independent Variables</bold></th>
<th align="center" valign="middle"><bold>Model N<xref ref-type="table-fn" rid="tfn1-ijerph-07-03211">a</xref></bold></th>
<th align="center" valign="middle"><bold>Regression Coefficient</bold></th>
<th align="center" valign="middle"><bold>Standard Error</bold></th>
<th align="center" valign="middle"><bold>P-value</bold></th>
<th align="center" valign="middle"><bold>Adjusted Model R<sup>2</sup></bold></th></tr></thead>
<tbody>
<tr>
<td colspan="6" align="center" valign="top">Including air exchange as potential predictor</td></tr>
<tr>
<td align="left" valign="top">1 Intercept<break/> Ln of air exchange<break/> Use air conditioning &gt; 30 d/yr<break/> Forced air heating (0/1)</td>
<td align="center" valign="top">35</td>
<td align="center" valign="top">0.870<break/>0.114<break/>−0.144<break/>−0.103</td>
<td align="center" valign="top">0.082<break/>0.039<break/>0.055<break/>0.058</td>
<td align="center" valign="top">&lt;0.0001<break/>0.01<break/>0.01<break/>0.08</td>
<td align="center" valign="top"><break/><break/><break/>38%</td></tr>
<tr>
<td colspan="6" align="center" valign="top">Excluding air exchange as potential predictor</td></tr>
<tr>
<td align="left" valign="top">2 Intercept<break/> Use air conditioning &gt; 30 d/yr<break/> Forced air heating (0/1)</td>
<td align="center" valign="top">35</td>
<td align="center" valign="top">0.698<break/>−0.179<break/>−0.107</td>
<td align="center" valign="top">0.062<break/>0.060<break/>0.064</td>
<td align="center" valign="top">&lt;0.0001<break/>0.01<break/>0.10</td>
<td align="center" valign="top"><break/><break/>23%</td></tr>
<tr>
<td align="left" valign="top">3 Intercept<break/> Use air conditioning &gt; 30 d/yr<break/> Forced air heating (0/1)</td>
<td align="center" valign="top">46</td>
<td align="center" valign="top">0.708<break/>−0.193<break/>−0.120</td>
<td align="center" valign="top">0.057<break/>0.054<break/>0.060</td>
<td align="center" valign="top">&lt;0.0001<break/>0.00<break/>0.05</td>
<td align="center" valign="top"><break/><break/>26%</td></tr></tbody></table>
<table-wrap-foot><fn id="tfn1-ijerph-07-03211">
<label>a</label>
<p>Models 1 and 2 are performed on the same homes for direct comparability, while Model 3 includes additional homes for which air exchange rate was not available.</p></fn></table-wrap-foot></table-wrap></sec></back></article>