<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="en" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">101238455</journal-id>
<journal-title>International Journal of Environmental Research and Public Health</journal-title>
<issn pub-type="ppub">1661-7827</issn>
<issn pub-type="epub">1660-4601</issn>
<publisher>
<publisher-name>Molecular Diversity Preservation International (MDPI)</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3390/ijerph7072978</article-id>
<article-id pub-id-type="publisher-id">ijerph-07-02978</article-id>
<article-categories>
<subj-group>
<subject>Article</subject></subj-group></article-categories>
<title-group>
<article-title>Total Fume and Metal Concentrations during Welding in Selected Factories in Jeddah, Saudi Arabia</article-title></title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Balkhyour</surname><given-names>Mansour Ahmed</given-names></name></contrib>
<contrib contrib-type="author">
<name><surname>Goknil</surname><given-names>Mohammad Khalid</given-names></name><xref ref-type="corresp" rid="c1-ijerph-07-02978">*</xref></contrib>
<aff id="af1-ijerph-07-02978">Environmental Sciences Department, Faculty of Meteorology, Environment and Arid Land Agriculture, King Abdulaziz University, P.O. Box 80208, Jeddah 21589, Saudi Arabia; E-Mail: <email>mbalkyhour@kau.edu.sa</email></aff></contrib-group>
<author-notes>
<corresp id="c1-ijerph-07-02978">
<label>*</label>Author to whom correspondence should be addressed; E-Mail: <email>mhgoknil@kau.edu.sa</email>; Tel.: +966-2-695-2000-64808; Fax: +966-2-670-1860.</corresp></author-notes>
<pub-date pub-type="ppub">
<month>7</month>
<year>2010</year></pub-date>
<pub-date pub-type="epub">
<day>22</day>
<month>7</month>
<year>2010</year></pub-date>
<volume>7</volume>
<issue>7</issue>
<fpage>2978</fpage>
<lpage>2987</lpage>
<history>
<date date-type="received">
<day>22</day>
<month>6</month>
<year>2010</year></date>
<date date-type="rev-recd">
<day>12</day>
<month>7</month>
<year>2010</year></date>
<date date-type="accepted">
<day>16</day>
<month>7</month>
<year>2010</year></date></history>
<permissions>
<copyright-statement>© 2010 by the authors; licensee Molecular Diversity Preservation International, Basel, Switzerland.</copyright-statement>
<copyright-year>2010</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/3.0">
<p>This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).</p></license></permissions>
<abstract>
<p>Welding is a major industrial process used for joining metals. Occupational exposure to welding fumes is a serious occupational health problem all over the world. The degree of risk to welder’s health from fumes depends on composition, concentration, and the length of exposure. The aim of this study was to investigate workers’ welding fume exposure levels in some industries in Jeddah, Saudi Arabia. In each factory, the air in the breathing zone within 0.5 m from welders was sampled during 8-hour shifts. Total particulates, manganese, copper, and molybdenum concentrations of welding fumes were determined. Mean values of eight-hour average particulate concentrations measured during welding at the welders breathing zone were 6.3 mg/m<sup>3</sup> (Factory 1), 5.3 mg/m<sup>3</sup> (Factory 2), 11.3 mg/m<sup>3</sup> (Factory 3), 6.8 mg/m<sup>3</sup> (Factory 4), 4.7 mg/m<sup>3</sup> (Factory 5), and 3.0 mg/m<sup>3</sup> (Factory 6). Mean values of airborne manganese, copper, and molybdenum levels measured during welding were in the range of 0.010 mg/m<sup>3</sup>–0.477 mg/m<sup>3</sup>, 0.001 mg/m<sup>3</sup>–0.080 mg/m<sup>3</sup> and 0.001 mg/m<sup>3</sup>–0.058 mg/m<sup>3</sup> respectively. Mean values of calculated equivalent exposure values were: 1.50 (Factory 1), 1.56 (Factory 2), 5.14 (Factory 3), 2.21 (Factory 4), 2.89 (Factory 5), and 1.20 (Factory 6). The welders in factories 1, 2, 3, and 4 were exposed to welding fume concentration above the SASO limit value, which may increase the risk of respiratory health problems.</p></abstract>
<kwd-group>
<kwd>fume</kwd>
<kwd>particulates</kwd>
<kwd>occupational exposure</kwd></kwd-group></article-meta></front>
<body>
<sec sec-type="intro">
<label>1.</label>
<title>Introduction</title>
<p>Occupational exposure to welding fume is a serious occupational health problem all over the world. Welding is a major industrial process used for joining metals. One of the most common types of welding technology is manual metal arc welding (MMAW) which uses a flux coated electrode. In this type of welding process, high heat from an electric arc is used to melt and fuse the metal at the joint between the two parts. All welding processes produce fumes, but maximum fumes are produced during arc welding. In MMAW, fume arises by vaporization of the core metal and flux components of the electrode. Vaporized metals react with air, producing metal oxides which condense and form fumes consisting of particles [<xref ref-type="bibr" rid="b1-ijerph-07-02978">1</xref>–<xref ref-type="bibr" rid="b3-ijerph-07-02978">3</xref>].</p>
<p>Welding fumes are a complex mixture composed of different metals. The composition and the rate of generation of welding fumes depend on the components of the metal being welded, coatings, types of electrodes or filler materials, operating conditions of the welding process (temperature, current), and the technique and skill of the welder. Types of metals commonly found in welding fumes include aluminum, beryllium, cadmium oxides, chromium, copper, fluorides, iron oxide, lead, manganese, molybdenum, nickel, vanadium and zinc oxides. Fumes from mild steel welding contain mostly iron, along with small amounts of additive metals like manganese, copper, and molybdenum [<xref ref-type="bibr" rid="b4-ijerph-07-02978">4</xref>–<xref ref-type="bibr" rid="b6-ijerph-07-02978">6</xref>].</p>
<p>Most of the particles in welding fume are less than 1μm in diameter when produced, but they appear to grow in size with time due to agglomeration [<xref ref-type="bibr" rid="b1-ijerph-07-02978">1</xref>,<xref ref-type="bibr" rid="b3-ijerph-07-02978">3</xref>,<xref ref-type="bibr" rid="b6-ijerph-07-02978">6</xref>,<xref ref-type="bibr" rid="b7-ijerph-07-02978">7</xref>]. Particle (0.5–0.7 μm in diameter) concentrations of welding fumes were reported to range between 9,800 particles/cm<sup>3</sup> and 82,000 particles/cm<sup>3</sup>, depending on voltage level [<xref ref-type="bibr" rid="b8-ijerph-07-02978">8</xref>]. The average particle size distribution of flux cored arc welding fumes by percentage was reported as: aerodynamic diameter &gt;5.8 μm: 6.01%, 1.1–5.8μm: 3.04%, 0.7–1.1 μm: 19.9%, 0.4–0.7 μm: 23.3%, and &lt;0.4 μm: 47.7% [<xref ref-type="bibr" rid="b9-ijerph-07-02978">9</xref>].</p>
<p>Exposure to welding fumes can cause numerous health problems. The degree of the risk to welder’s health from fume exposure depends on the composition, concentration, and the length of time the welder is exposed. When inhaled, welding fumes can enter the lungs, bloodstream, brain nerve cells, spinal cord and other organs and can cause both short and long term health effects. Acute exposure to welding fumes can result eye, nose, and throat irritation, fever, chills, nausea, shortness of breath, muscle pain and metallic taste in the mouth. Chronic exposure to welding fumes can result in respiratory effects, including coughing, decreased pulmonary function, and occupational asthma [<xref ref-type="bibr" rid="b10-ijerph-07-02978">10</xref>–<xref ref-type="bibr" rid="b15-ijerph-07-02978">15</xref>].</p>
<p>Many of the reported epidemiology studies are difficult to compare because of the wide differences in worker populations, industrial settings, welding techniques, duration of exposure, and other occupational exposures besides welding fumes. Epidemiological studies have indicated that large numbers of welders experience some type of respiratory illness. Respiratory effects observed include acute and chronic bronchitis, air passage irritation, pneumoconiosis “arc welder’s siderosis”, occupational asthma, and possible increase in the incidence of lung cancer [<xref ref-type="bibr" rid="b10-ijerph-07-02978">10</xref>–<xref ref-type="bibr" rid="b12-ijerph-07-02978">12</xref>,<xref ref-type="bibr" rid="b15-ijerph-07-02978">15</xref>–<xref ref-type="bibr" rid="b22-ijerph-07-02978">22</xref>].</p>
<p>The presence of soluble metals such as iron, chromium, nickel, copper, and manganese, and the various complexes formed by these different metals in welding fumes are likely to be important in the pulmonary responses observed after welding fume exposure [<xref ref-type="bibr" rid="b23-ijerph-07-02978">23</xref>]. Manganese is known to be bio-available to and neurotoxic for the central nervous system. Although an essential metal, manganese overexposure may cause manganism, a Parkinson-like syndrome [<xref ref-type="bibr" rid="b24-ijerph-07-02978">24</xref>], although epidemiological evidence linking welding exposures to Parkinson’s disease is still controversial [<xref ref-type="bibr" rid="b25-ijerph-07-02978">25</xref>].</p>
<p>The aim of this study was to investigate workers welding fume exposure levels in some industries in Jeddah, Saudi Arabia.</p></sec>
<sec>
<label>2.</label>
<title>Experimental Section</title>
<p>The investigation was carried out in welding areas of six factories located in Jeddah. These factories were selected to be representative of manual metal arc welding processes. These factories were Al Kawther, Al Mutlak, Jamjoom, Binladin, Hidada (plant 1), and Hidada (plant 2). Factories were represented by numbers in the results in mixed order. Sizes of the work places, number of total workers and welders, work schedule and electrode types during the welding are presented for each factory in <xref ref-type="table" rid="t1-ijerph-07-02978">Table 1</xref>.</p>
<p>Ten samples were collected from each factory for determination of particulate concentrations in the welding areas. A RAC battery-powered particulate/gas sampler was used for sampling. It consists of vacuum pump (19 lpm), motor (6,000 rpm), flow-meter (0–6 lpm), battery (12V, 4 amp), and battery charger. A 47 mm Millipore filter holder was connected to RAC sampler by plastic tubing. Type AA, 0.8 μm pore size, 47 mm MF-Millipore membrane filters were used in filter holder for particulate collection.</p>
<p>In each factory, the air in the breathing zone within 0.5 m from exposed workers was sampled during an 8-hour shift. One to four samples per shift were collected, each over a period of about two hours. The measured ratio of sampling period to welding period was constant for 91% of samples, so measured concentrations represent the exposure concentrations during work hours.</p>
<p>Samples were collected by drawing air at constant flow rate through a pre-weighed Millipore filter. The filters were weighed using an analytical balance with a minimum measurable weight of 0.1 mg. One to four samples per shift were collected, each over a period of about two hours. The rate of air intake through the filter was adjusted between 2 and 3 liters per minute before the start of sampling. At the end of the sampling period, each filter was carefully transferred from the filter holder into a clean, labeled, and self-sealing plastic box. After sampling, the filters were transferred to the laboratory and left for 24 hours, and weighed to determine the total mass of particulate collected on each filter.</p>
<p>After determining the total welding fume weight on the filter, a metal specific analysis was performed on the filter samples. In the laboratory, the filters were transferred to a 50 mL acid washed beaker using plastic forceps. The samples were digested at 100 °C with addition of 10 mL 70% nitric acid. In order to reduce volatilization watch glasses were placed over the beakers. After 60 minutes, the watch glasses were removed and the samples heated to reduce the volume of acid to near dryness. When cool, distilled water was added and the samples were filtered through a Whatman No.41 filter paper. Manganese, copper, and molybdenum concentrations of particulates were then determined by atomic absorption spectrophotometry.</p></sec>
<sec sec-type="results|discussion">
<label>3.</label>
<title>Results and Discussion</title>
<p>Materials used in welding were mild steel and alloy of iron. Work places were semi-open. A helmet and face shield were used as protective equipment by the welders, who were not using a mask, except in Factory No 2. Mechanical ventilation was used only in Factory No 2. Natural air movement was occurring in all factories.</p>
<p>Ranges of measured particulate concentrations in the breathing zone of the welders for each factory were: 4.0 mg/m<sup>3</sup>–18.0 mg/m<sup>3</sup> (Factory 1), 4.5 mg/m<sup>3</sup>–14.0 mg/m<sup>3</sup> (Factory 2), 6.5 mg/m<sup>3</sup>–57.5 mg/m<sup>3</sup> (Factory 3), 5.5 mg/m<sup>3</sup>–13.5 mg/m<sup>3</sup> (Factory 4), 1.0 mg/m<sup>3</sup>–14.0 mg/m<sup>3</sup> (Factory 5), and 1.5 mg/m<sup>3</sup>–5.0 mg/m<sup>3</sup> (Factory 6). Higher concentrations were measured when either two welders worked for the same job or welders positioned downwind.</p>
<p>SASO (Saudi Standards, Metrology and Quality Organization) has established permissible exposure levels (PELs) for toxic and hazardous substances. PELs represent 8-hour time weighted average (TWA) concentrations for an 8-hour work shift of a 40-hour work week. SASO was set PELs of 15 mg/m<sup>3</sup> (total) and 5 mg/m<sup>3</sup> (respirable fraction) as 8-hour TWA for inert or nuisance dust [<xref ref-type="bibr" rid="b26-ijerph-07-02978">26</xref>].</p>
<p>Measured particulate concentrations were converted into 8-hour average concentrations in order to evaluate health risks. Break times were assumed as non exposure periods. <xref ref-type="table" rid="t2-ijerph-07-02978">Table 2</xref> shows calculated 8-hour average particulate concentrations in the welding fumes for each factory. Mean values were 6.3 mg/m<sup>3</sup> (Factory 1), 5.3 mg/m<sup>3</sup> (Factory 2), 11.3 mg/m<sup>3</sup> (Factory 3), 6.8 mg/m<sup>3</sup> (Factory 4), 4.7 mg/m<sup>3</sup> (Factory 5), and 3.0 mg/m<sup>3</sup> (Factory 6).</p>
<p>Exposures to welding fumes in factories 1, 2, 3, and 4 were above the permissible exposure limit value (5 mg/m<sup>3</sup>) established by SASO. Exposures to welding fumes in factories 5 and 6 were below the limit value. Compliance with 8-hour TLV for each factory is determined by t-test. Mean exposures were above the TLV in Factory 1 (75% confidence), Factory 2 (55% confidence), Factory 3 (97.5% confidence), and Factory 4 (97.5% confidence). Mean exposures were below the TLV in Factory 5 (55% confidence) and Factory 6 (99.99% confidence).</p>
<p>Measured average concentration of welding fumes in the breathing zone of welders in a big production plant located in Arak, Iran was 7.9 mg/m<sup>3</sup> for manual metal arc welding. Welders in this study showed decreased pulmonary function and an increased prevalence in respiratory symptoms [<xref ref-type="bibr" rid="b12-ijerph-07-02978">12</xref>]. Welding area of four factories in New Zealand mean exposure values of total fume ranged between 0.125 mg/m<sup>3</sup> and 5.28 mg/m<sup>3</sup> [<xref ref-type="bibr" rid="b14-ijerph-07-02978">14</xref>]. Time weighted average concentrations of the welding fumes released during flux cored arc welding at the workers’ breathing zone in six industrial plants were 0.2 mg/m<sup>3</sup>–24.3 mg/m<sup>3</sup> [<xref ref-type="bibr" rid="b27-ijerph-07-02978">27</xref>]. Average total fume concentrations ranged from 4.73 mg/m<sup>3</sup>–5.90 mg/m<sup>3</sup> at the welders’ breathing zone, in a study of professional welders performing shielded metal arc welding on carbon steel under field conditions [<xref ref-type="bibr" rid="b28-ijerph-07-02978">28</xref>].</p>
<p>Investigations of the respiratory effects of welding exposure in manual arc welders exposed welding processes without respiratory protection reported that respiratory symptoms and chronic bronchitis were more prevalent in welders than in the unexposed control group [<xref ref-type="bibr" rid="b16-ijerph-07-02978">16</xref>–<xref ref-type="bibr" rid="b18-ijerph-07-02978">18</xref>,<xref ref-type="bibr" rid="b29-ijerph-07-02978">29</xref>]. A study comparing the neuropsychological function, emotional status, visual function, and illness prevalence of welders primarily involved in steel welding, and exposed to welding fumes for an average of 24.9 years with unexposed, non welder controls concluded that welders had poorer color vision and emotional status, and increased prevalence of illness and psychiatric symptoms [<xref ref-type="bibr" rid="b30-ijerph-07-02978">30</xref>].</p>
<p>In our study the welders in factories 1, 2, 3, and 4 were exposed to welding fume concentration above the limit value, which increases the risk of respiratory health problems.</p>
<p>Eight hour average concentrations of measured manganese, copper, and molybdenum in welding fume for each factory are presented in <xref ref-type="table" rid="t3-ijerph-07-02978">Table 3</xref>. SASO has set the following permissible exposure levels (PELs): copper fumes, 0.1 mg/m<sup>3</sup>; manganese, 5 mg/m<sup>3</sup> (ceiling); molybdenum, 5 mg/m<sup>3</sup> (soluble), 15 mg/m<sup>3</sup> (insoluble), as TWA for a normal 8-hour workday and a 40-hour work week [<xref ref-type="bibr" rid="b26-ijerph-07-02978">26</xref>].</p>
<p>ACGIH has assigned threshold limit values (TLV): Copper fume, 0.2 mg/m<sup>3</sup>; manganese, 0.2 mg/m<sup>3</sup>; and molybdenum 5 mg/m<sup>3</sup> (soluble), 10 mg/m<sup>3</sup> (insoluble), as TWA for a normal 8-hour workday and a 40-hour work week [<xref ref-type="bibr" rid="b31-ijerph-07-02978">31</xref>].</p>
<p>Measured manganese concentrations in all factories were well below the SASO permissible exposure level (PEL 8h-TWA, ceiling) of 5 mg/m<sup>3</sup>. Measured manganese concentrations in factories 1, 2, 4, and 6 were below the ACGIH threshold limit value (TLV 8h-TWA) of 0.2 mg/m<sup>3</sup>, but they were exceeding the limit value in factories 3 and 5 for two samples.</p>
<p>Measured copper and molybdenum concentrations in all factories were well below the SASO permissible exposure levels (PEL 8h-TWA) and ACGIH threshold limit values (TLV 8h-TWA).</p>
<p>Mean values of airborne manganese levels measured during welding were 0.22 mg/m<sup>3</sup> in Factory 3 and 0.21 mg/m<sup>3</sup> in Factory 5, which slightly exceed ACGIH threshold limit value (TLV 8h-TWA) of 0.2 mg/m<sup>3</sup>.</p>
<p>Average concentration of manganese in welding fumes in the welders breathing zone was reported as 0.18 mg/m<sup>3</sup> in an automobile parts manufacturing factory at Tehran, Iran and 1.45 mg/m<sup>3</sup> (geometric mean) at a Beijing (China) vehicle factory [<xref ref-type="bibr" rid="b3-ijerph-07-02978">3</xref>,<xref ref-type="bibr" rid="b5-ijerph-07-02978">5</xref>]. In a study for professional welders performing shielded metal arc welding on carbon steel under field conditions, average concentration of manganese in welding fumes in the welders breathing zone ranged from 0.06 mg/m<sup>3</sup>–0.16 mg/m<sup>3</sup> [<xref ref-type="bibr" rid="b28-ijerph-07-02978">28</xref>]. In a study on confined space welding in the construction of a new span of the San Francisco-Oakland Bay Bridge, the mean time weighted average of manganese in air ranged from 0.11–0.46 mg/m<sup>3</sup> (55% &gt; 0.20 mg/m<sup>3</sup>) [<xref ref-type="bibr" rid="b32-ijerph-07-02978">32</xref>]. The investigation, after examining several large data sets to characterize manganese, iron, and total particulate mass exposures resulting from welding operations suggested that exposures to manganese are frequently at or above the current ACGIH threshold limit value of 0.2 mg/m<sup>3</sup> [<xref ref-type="bibr" rid="b33-ijerph-07-02978">33</xref>].</p>
<p>The equivalent exposure for a fume composed of several substances is calculated by using addition formula which requires the sum of the individual concentration (C)/TLV ratios [<xref ref-type="bibr" rid="b1-ijerph-07-02978">1</xref>,<xref ref-type="bibr" rid="b26-ijerph-07-02978">26</xref>]:
<disp-formula>
<mml:math display="block">
<mml:mrow>
<mml:msub>
<mml:mtext>E</mml:mtext>
<mml:mtext>m</mml:mtext></mml:msub>
<mml:mo>=</mml:mo>
<mml:msub>
<mml:mtext>C</mml:mtext>
<mml:mn>1</mml:mn></mml:msub>
<mml:mo>/</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mtext>TLV</mml:mtext></mml:mrow>
<mml:mn>1</mml:mn></mml:msub>
<mml:mo>+</mml:mo>
<mml:msub>
<mml:mtext>C</mml:mtext>
<mml:mn>2</mml:mn></mml:msub>
<mml:mo>/</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mtext>TLV</mml:mtext></mml:mrow>
<mml:mn>2</mml:mn></mml:msub>
<mml:mo>+</mml:mo>
<mml:msub>
<mml:mtext>C</mml:mtext>
<mml:mn>3</mml:mn></mml:msub>
<mml:mo>/</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mtext>TLV</mml:mtext></mml:mrow>
<mml:mn>3</mml:mn></mml:msub>
<mml:mo>+</mml:mo>
<mml:mo>…</mml:mo>
<mml:mo>…</mml:mo>
<mml:mo>+</mml:mo>
<mml:msub>
<mml:mtext>C</mml:mtext>
<mml:mtext>n</mml:mtext></mml:msub>
<mml:mo>/</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mtext>TLV</mml:mtext></mml:mrow>
<mml:mtext>n</mml:mtext></mml:msub>
<mml:mo>+</mml:mo>
<mml:msub>
<mml:mtext>C</mml:mtext>
<mml:mrow>
<mml:mtext>rest</mml:mtext></mml:mrow></mml:msub>
<mml:mo>/</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mtext>TLV</mml:mtext></mml:mrow>
<mml:mrow>
<mml:mtext>rest</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:math></disp-formula>where 1, 2,… n represent the individual substances and “rest” indicates that fraction of the fumes for which either there is no analysis or no TLV, and which is assigned to typically have a TLV<sub>rest</sub> corresponding to that for respirable fraction of nuisance dust (5 mg/m<sup>3</sup>). E<sub>m</sub> is the equivalent exposure for the mixture. The value of E<sub>m</sub> will not exceed the unity for satisfaction of the TLV.</p>
<p>Ranges of calculated equivalent exposure values were: 1.19–1.70 (Factory 1), 1.03–2.31 (Factory 2), 3.53–7.13 (Factory 3), 2.05–2.46 (Factory 4), 1.23–3.96 (Factory 5), and 0.95–1.40 (Factory 6). Mean values of equivalent exposures were: 1.50 (Factory 1), 1.56 (Factory 2), 5.14 (Factory 3), 2.21 (Factory 4), 2.89 (Factory 5), and 1.20 (Factory 6). In all factories equivalent exposure levels were exceeding the threshold limit values, except for one sample from Factory 6.</p>
<p>Depending on the welding process and the composition of the welding electrode, manganese may be present in different oxidation states and have different solubility properties. These differences may affect the biological responses to manganese after the inhalation of welding fumes. Manganese intoxication and the associated neurological symptoms have been reported in individual cases of welders who have been exposed to high concentrations of manganese-containing welding fumes due to work in poorly ventilated areas [<xref ref-type="bibr" rid="b4-ijerph-07-02978">4</xref>]. Long term, low level exposure to welding fumes increases serum concentrations of manganese and iron. Occupational exposure to welding fume appears to induce oxidative stress among career welders [<xref ref-type="bibr" rid="b5-ijerph-07-02978">5</xref>]. In a study among 43 welders exposed to welding fume containing manganese, 11 cases of manganism were identified presenting with the following symptoms; sleep disturbance, mood changes, bradykinesia, headaches, sexual dysfunction, olfaction loss, muscular rigidity, tremors, hallucinations, slurred speech, postural instability, monotonous voice, and facial masking [<xref ref-type="bibr" rid="b24-ijerph-07-02978">24</xref>]. Although manganism was observed in highly exposed workers, the scant exposure-response data available for welders do not support a conclusion that welding is associated with clinical neurotoxicity [<xref ref-type="bibr" rid="b34-ijerph-07-02978">34</xref>].</p></sec>
<sec sec-type="conclusions">
<label>4.</label>
<title>Conclusions</title>
<p>This study examined the exposure of welders in industries to welding fume. Results of the investigation showed that mean values of eight hours average particulate concentrations measured during welding at the welders breathing zone were 6.3 mg/m<sup>3</sup> (Factory 1), 5.3 mg/m<sup>3</sup> (Factory 2), 11.3 mg/m<sup>3</sup> (Factory 3), 6.8 mg/m<sup>3</sup> (Factory 4), 4.7 mg/m<sup>3</sup> (Factory 5), and 3.0 mg/m<sup>3</sup> (Factory 6). Mean exposures to welding fumes were above the TLV in Factory 1 (75% confidence), Factory 2 (55% confidence), Factory 3 (97.5% confidence), and Factory 4 (97.5% confidence). Mean exposures were below the TLV in Factory 5 (55% confidence) and Factory 6 (99.99% confidence).</p>
<p>The welders in Factories 1, 2, 3, and 4 were exposed to welding fume concentration above the limit value, which increases the risk of respiratory health problems. Natural air ventilation helped to reduce these levels but the exposures were not considered to be controlled.</p>
<p>Mean values of airborne manganese, copper, and molybdenum levels measured during welding were in the range of 0.010 mg/m<sup>3</sup>–0.477 mg/m<sup>3</sup>, 0.001 mg/m<sup>3</sup>–0.080 mg/m<sup>3</sup> and 0.001 mg/m<sup>3</sup>–0.058 mg/m<sup>3</sup>, respectively. Measured manganese concentrations in all factories were well below the SASO permissible exposure level (PEL 8h-TWA, ceiling) of 5 mg/m<sup>3</sup>. Measured manganese concentrations in factories 1, 2, 4, and 6 were below the ACGIH threshold limit value (TLV 8h-TWA) of 0.2 mg/m<sup>3</sup>, but they exceeded the limit value in factories 3 and 5 for two samples. Mean values of airborne manganese levels measured during welding were 0.22 mg/m<sup>3</sup> in Factory 3 and 0.21 mg/m<sup>3</sup> in Factory 5, which slightly exceed ACGIH threshold limit value (TLV 8h-TWA) of 0.2 mg/m<sup>3</sup>.</p>
<p>Measured copper and molybdenum concentrations in all factories were well below the SASO permissible exposure levels (PEL 8h-TWA) and ACGIH threshold limit values (TLV 8h-TWA). Mean values of calculated equivalent exposures values were: 1.50 (Factory 1), 1.56 (Factory 2), 5.14 (Factory 3), 2.21 (Factory 4), 2.89 (Factory 5), and 1.20 (Factory 6). In all factories equivalent exposure levels were exceeding the threshold limit values, except for one sample taken in Factory 6.</p></sec></body>
<back>
<ack>
<p>We thank to members of the management boards of the industrial companies for their cooperation.</p></ack>
<ref-list>
<title>References</title>
<ref id="b1-ijerph-07-02978"><label>1</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Stern</surname><given-names>RM</given-names></name></person-group><article-title>Occupational Exposure in the Welding Industry: Health Risk Assessment</article-title><source>Health Effects of Combined Exposures to Chemicals in Work and Community Environments; Interim Document 11</source><publisher-name>WHO</publisher-name><publisher-loc>Copenhagen, Denmark</publisher-loc><year>1983</year></citation></ref>
<ref id="b2-ijerph-07-02978"><label>2</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Taylor</surname><given-names>MD</given-names></name><name><surname>Roberts</surname><given-names>JR</given-names></name><name><surname>Leonard</surname><given-names>SS</given-names></name><name><surname>Shi</surname><given-names>X</given-names></name><name><surname>Antonini</surname><given-names>JM</given-names></name></person-group><article-title>Effects of Welding Fumes of Differing Composition and Solubility on Free Radical Production and Acute Lung Injury and Inflammation in Rats</article-title><source>Toxicol. Sci</source><year>2003</year><volume>75</volume><fpage>181</fpage><lpage>191</lpage><pub-id pub-id-type="doi">10.1093/toxsci/kfg173</pub-id><pub-id pub-id-type="pmid">12832661</pub-id></citation></ref>
<ref id="b3-ijerph-07-02978"><label>3</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mansouri</surname><given-names>N</given-names></name><name><surname>Atbi</surname><given-names>F</given-names></name><name><surname>Moharamnezhad</surname><given-names>N</given-names></name><name><surname>Rahbaran</surname><given-names>DA</given-names></name><name><surname>Alahiari</surname><given-names>M</given-names></name></person-group><article-title>Gravimetric and Analytical Evaluation of Welding Fume in an Automobile Part Manufacturing Factory</article-title><source>J. Res. Health Sci</source><year>2008</year><volume>8</volume><fpage>1</fpage><lpage>8</lpage><pub-id pub-id-type="pmid">23344067</pub-id></citation></ref>
<ref id="b4-ijerph-07-02978"><label>4</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antonini</surname><given-names>JM</given-names></name><name><surname>Santamaria</surname><given-names>AB</given-names></name><name><surname>Jenkins</surname><given-names>NT</given-names></name><name><surname>Albini</surname><given-names>E</given-names></name><name><surname>Lucchini</surname><given-names>R</given-names></name></person-group><article-title>Fate of Manganese Associated with the Inhalation of Welding Fumes: Potential Neurological Effects</article-title><source>Neurotoxicology</source><year>2006</year><volume>27</volume><fpage>304</fpage><lpage>310</lpage><pub-id pub-id-type="doi">10.1016/j.neuro.2005.09.001</pub-id><pub-id pub-id-type="pmid">16219356</pub-id></citation></ref>
<ref id="b5-ijerph-07-02978"><label>5</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jane</surname><given-names>G</given-names></name><name><surname>Zhang</surname><given-names>L</given-names></name><name><surname>Lu</surname><given-names>L</given-names></name><name><surname>Wu</surname><given-names>P</given-names></name><name><surname>Zheng</surname><given-names>W</given-names></name></person-group><article-title>Occupational Exposure to Welding Fume among Welders: Alterations of Manganese, Iron, Zinc, Copper, and Lead in Body Fluids and the Oxidative Stress Status</article-title><source>J. Occup. Environ. Med</source><year>2004</year><volume>46</volume><fpage>241</fpage><lpage>248</lpage><pub-id pub-id-type="doi">10.1097/01.jom.0000116900.49159.03</pub-id><pub-id pub-id-type="pmid">15091287</pub-id></citation></ref>
<ref id="b6-ijerph-07-02978"><label>6</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ekici</surname><given-names>A</given-names></name><name><surname>Bilgili</surname><given-names>Y</given-names></name><name><surname>Ekici</surname><given-names>M</given-names></name><name><surname>Unal</surname><given-names>B</given-names></name><name><surname>Akin</surname><given-names>A</given-names></name><name><surname>Erdal</surname><given-names>HH</given-names></name><name><surname>Arslan</surname><given-names>M</given-names></name><name><surname>Kocuigit</surname><given-names>P</given-names></name></person-group><article-title>High-resolution Computed Tomography Findings in Arc-welders</article-title><source>Turkish Resp. J</source><year>2006</year><volume>7</volume><fpage>052</fpage><lpage>055</lpage></citation></ref>
<ref id="b7-ijerph-07-02978"><label>7</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Isaxon</surname><given-names>C</given-names></name><name><surname>Pagels</surname><given-names>J</given-names></name><name><surname>Gudmundsson</surname><given-names>A</given-names></name><name><surname>Asbach</surname><given-names>C</given-names></name><name><surname>John</surname><given-names>AC</given-names></name><name><surname>Kuhlbusch</surname><given-names>TAJ</given-names></name><name><surname>Karlsson</surname><given-names>JE</given-names></name><name><surname>Kammer</surname><given-names>R</given-names></name><name><surname>Tinnerberg</surname><given-names>H</given-names></name><name><surname>Nielsen</surname><given-names>J</given-names></name><name><surname>Bohgard</surname><given-names>M</given-names></name></person-group><article-title>Characteristics of Welding Fume Aerosol Investigated in Three Swedish Workshops</article-title><source>J. Phys: Conf. Series</source><year>2009</year><volume>151</volume><fpage>0212059</fpage></citation></ref>
<ref id="b8-ijerph-07-02978"><label>8</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hovde</surname><given-names>C</given-names></name><name><surname>Raynor</surname><given-names>P</given-names></name></person-group><article-title>Effects of Voltage and Wire Feed Speed on Weld Fume Characteristics</article-title><source>J. Occup. Environ. Hyg</source><year>2007</year><volume>4</volume><fpage>903</fpage><lpage>912</lpage><pub-id pub-id-type="doi">10.1080/15459620701713470</pub-id><pub-id pub-id-type="pmid">17957560</pub-id></citation></ref>
<ref id="b9-ijerph-07-02978"><label>9</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jenkins</surname><given-names>NT</given-names></name><name><surname>Pierce</surname><given-names>WMG</given-names></name><name><surname>Eagar</surname><given-names>TW</given-names></name></person-group><article-title>Particle Size Distribution of Gas Metal and Flux Cored Arc Welding Fumes</article-title><source>Weld. J</source><year>2005</year><volume>84</volume><fpage>156</fpage><lpage>163</lpage></citation></ref>
<ref id="b10-ijerph-07-02978"><label>10</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antonini</surname><given-names>JM</given-names></name></person-group><article-title>Health Effects of Welding</article-title><source>Crit. Rev. Toxicol</source><year>2003</year><volume>33</volume><fpage>61</fpage><lpage>103</lpage><pub-id pub-id-type="doi">10.1080/713611032</pub-id><pub-id pub-id-type="pmid">12585507</pub-id></citation></ref>
<ref id="b11-ijerph-07-02978"><label>11</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antonini</surname><given-names>JM</given-names></name><name><surname>Taylor</surname><given-names>M</given-names></name><name><surname>Zimmer</surname><given-names>A</given-names></name><name><surname>Roberts</surname><given-names>J</given-names></name></person-group><article-title>Pulmonary Responses to Welding Fumes: Role of Metal Constituents</article-title><source>J. Toxicol. Environ. Health A</source><year>2003</year><volume>67</volume><fpage>223</fpage><lpage>249</lpage></citation></ref>
<ref id="b12-ijerph-07-02978"><label>12</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pourtaghi</surname><given-names>G</given-names></name><name><surname>Kakooei</surname><given-names>H</given-names></name><name><surname>Salem</surname><given-names>M</given-names></name><name><surname>Pourtaghi</surname><given-names>F</given-names></name><name><surname>Lahmi</surname><given-names>M</given-names></name></person-group><article-title>Pulmonary Effects of Occupational Exposure to Welding Fumes</article-title><source>Aust. J. Basic Appl. Sci</source><year>2009</year><volume>3</volume><fpage>3291</fpage><lpage>3296</lpage></citation></ref>
<ref id="b13-ijerph-07-02978"><label>13</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sobaszek</surname><given-names>A</given-names></name><name><surname>Boulenguez</surname><given-names>C</given-names></name><name><surname>Frimat</surname><given-names>P</given-names></name><name><surname>Robin</surname><given-names>H</given-names></name><name><surname>Haguenoer</surname><given-names>JM</given-names></name><name><surname>Edme</surname><given-names>JL</given-names></name></person-group><article-title>Acute Respiratory Effects of Exposure to Stainless Steel and Mild Steel Welding Fumes</article-title><source>J. Occup. Environ. Med</source><year>2000</year><volume>42</volume><fpage>923</fpage><lpage>931</lpage><pub-id pub-id-type="doi">10.1097/00043764-200009000-00016</pub-id><pub-id pub-id-type="pmid">10998769</pub-id></citation></ref>
<ref id="b14-ijerph-07-02978"><label>14</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fishwick</surname><given-names>D</given-names></name><name><surname>Bradshaw</surname><given-names>L</given-names></name><name><surname>Slater</surname><given-names>T</given-names></name><name><surname>Curran</surname><given-names>A</given-names></name><name><surname>Pearce</surname><given-names>N</given-names></name></person-group><article-title>Respiratory Symptoms and Lung Function Change in Welders: Are They Associated with Workplace Exposures?</article-title><source>J. New Zeal. Med. Assoc</source><year>2004</year><volume>117</volume><fpage>1193</fpage></citation></ref>
<ref id="b15-ijerph-07-02978"><label>15</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hannu</surname><given-names>T</given-names></name><name><surname>Pipari</surname><given-names>R</given-names></name><name><surname>Kasurinen</surname><given-names>H</given-names></name><name><surname>Keskinen</surname><given-names>H</given-names></name><name><surname>Tuppurainen</surname><given-names>M</given-names></name><name><surname>Tuomi</surname><given-names>T</given-names></name></person-group><article-title>Occupational Asthma due to Manual Metal-Arc Welding of Special Stainless Steels</article-title><source>Eur. Respir. J</source><year>2005</year><volume>26</volume><fpage>736</fpage><lpage>739</lpage><pub-id pub-id-type="doi">10.1183/09031936.05.00130504</pub-id><pub-id pub-id-type="pmid">16204606</pub-id></citation></ref>
<ref id="b16-ijerph-07-02978"><label>16</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ozdemir</surname><given-names>O</given-names></name><name><surname>Numanaoglu</surname><given-names>N</given-names></name><name><surname>Gonullu</surname><given-names>U</given-names></name><name><surname>Savas</surname><given-names>I</given-names></name><name><surname>Alper</surname><given-names>D</given-names></name><name><surname>Gurses</surname><given-names>H</given-names></name></person-group><article-title>Chronic Effects of Welding Exposure on Pulmonary Function Tests and Respiratory Symptoms</article-title><source>J. Occup. Environ. Med</source><year>1995</year><volume>52</volume><fpage>800</fpage><lpage>803</lpage><pub-id pub-id-type="doi">10.1136/oem.52.12.800</pub-id></citation></ref>
<ref id="b17-ijerph-07-02978"><label>17</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jafari</surname><given-names>AJ</given-names></name><name><surname>Assari</surname><given-names>MJ</given-names></name></person-group><article-title>Respiratory Effects from Work-Related Exposure to Welding Fumes in Hamada, Iran</article-title><source>Archs. Environ. Health</source><year>2004</year><volume>59</volume><fpage>116</fpage><lpage>120</lpage><pub-id pub-id-type="doi">10.3200/AEOH.59.3.116-120</pub-id></citation></ref>
<ref id="b18-ijerph-07-02978"><label>18</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jayawardana</surname><given-names>P</given-names></name><name><surname>Abeysena</surname><given-names>C</given-names></name></person-group><article-title>Respiratory Health of Welders in a Container Yard, Sri Lanka</article-title><source>Occup. Med</source><year>2009</year><volume>59</volume><fpage>226</fpage><lpage>229</lpage><pub-id pub-id-type="doi">10.1093/occmed/kqn166</pub-id></citation></ref>
<ref id="b19-ijerph-07-02978"><label>19</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Contreras</surname><given-names>GR</given-names></name><name><surname>Chan-Yeung</surname><given-names>M</given-names></name></person-group><article-title>Bronchial Reactions to Exposure to Welding Fumes</article-title><source>J. Occup. Environ. Med</source><year>1997</year><volume>54</volume><fpage>836</fpage><lpage>839</lpage><pub-id pub-id-type="doi">10.1136/oem.54.11.836</pub-id></citation></ref>
<ref id="b20-ijerph-07-02978"><label>20</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Siew</surname><given-names>SS</given-names></name><name><surname>Kauppinen</surname><given-names>T</given-names></name><name><surname>Kyyronen</surname><given-names>P</given-names></name><name><surname>Heikkila</surname><given-names>P</given-names></name><name><surname>Pukkala</surname><given-names>E</given-names></name></person-group><article-title>Exposure to Iron and Welding Fumes and Risk of Lung Cancer</article-title><source>Scand. J. Work Env. Health</source><year>2009</year><volume>34</volume><fpage>444</fpage><lpage>450</lpage></citation></ref>
<ref id="b21-ijerph-07-02978"><label>21</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>El-Zein</surname><given-names>M</given-names></name><name><surname>Infante-Rivard</surname><given-names>C</given-names></name><name><surname>Malo</surname><given-names>JL</given-names></name><name><surname>Gautrin</surname><given-names>D</given-names></name></person-group><article-title>Is Metal Fume Fewer a determinant of Welding Related Respiratory Symptoms and/or Increased Bronchial Responsiveness? A Longitudinal Study</article-title><source>J. Occup. Environ. Med</source><year>2005</year><volume>62</volume><fpage>688</fpage><lpage>694</lpage><pub-id pub-id-type="doi">10.1136/oem.2004.018796</pub-id></citation></ref>
<ref id="b22-ijerph-07-02978"><label>22</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antonini</surname><given-names>JM</given-names></name><name><surname>Lewis</surname><given-names>AB</given-names></name><name><surname>Roberts</surname><given-names>JR</given-names></name><name><surname>Whaley</surname><given-names>DA</given-names></name></person-group><article-title>Pulmonary Effects of Welding Fumes: Review of Worker and Experimental Animal Studies</article-title><source>Am. J. Ind. Med</source><year>2003</year><volume>43</volume><fpage>350</fpage><lpage>360</lpage><pub-id pub-id-type="doi">10.1002/ajim.10194</pub-id><pub-id pub-id-type="pmid">12645092</pub-id></citation></ref>
<ref id="b23-ijerph-07-02978"><label>23</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Antonini</surname><given-names>JM</given-names></name><name><surname>Lawryk</surname><given-names>NJ</given-names></name><name><surname>Murthy</surname><given-names>GGK</given-names></name><name><surname>Brain</surname><given-names>JD</given-names></name></person-group><article-title>Effect of Welding Fume Solubility on Lung Macrophage Viability and Function <italic>in Vitro</italic></article-title><source>J. Toxicol. Environ. Health A</source><year>1999</year><volume>58</volume><fpage>343</fpage><lpage>363</lpage><pub-id pub-id-type="doi">10.1080/009841099157205</pub-id><pub-id pub-id-type="pmid">10580758</pub-id></citation></ref>
<ref id="b24-ijerph-07-02978"><label>24</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bowler</surname><given-names>RM</given-names></name><name><surname>Nakagawa</surname><given-names>S</given-names></name><name><surname>Drezgic</surname><given-names>M</given-names></name><name><surname>Roels</surname><given-names>HA</given-names></name><name><surname>Park</surname><given-names>RM</given-names></name><name><surname>Diamond</surname><given-names>E</given-names></name><name><surname>Mergler</surname><given-names>D</given-names></name><name><surname>Bouchard</surname><given-names>M</given-names></name><name><surname>Bowler</surname><given-names>RP</given-names></name><name><surname>Kollerg</surname><given-names>W</given-names></name></person-group><article-title>Sequelae of Fume Exposure in Confined Space Welding: A Neurological Neuropsychological Case Series</article-title><source>Neurotoxicology</source><year>2007</year><volume>28</volume><fpage>298</fpage><lpage>311</lpage><pub-id pub-id-type="doi">10.1016/j.neuro.2006.11.001</pub-id><pub-id pub-id-type="pmid">17169432</pub-id></citation></ref>
<ref id="b25-ijerph-07-02978"><label>25</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Flynn</surname><given-names>MR</given-names></name><name><surname>Susi</surname><given-names>P</given-names></name></person-group><article-title>Neurological Risks Associated with Manganese Exposure from Welding Operations</article-title><source>Int. J. Hyg. Environ. Health</source><year>2009</year><volume>212</volume><fpage>459</fpage><lpage>469</lpage><pub-id pub-id-type="doi">10.1016/j.ijheh.2008.12.003</pub-id><pub-id pub-id-type="pmid">19181573</pub-id></citation></ref>
<ref id="b26-ijerph-07-02978"><label>26</label><citation citation-type="book"><collab>SASO 320</collab><source>Industrial Safety and Health Regulations, Part 4: Hazardous Material- Section 4.6. Toxic and Hazardous Substances</source><publisher-name>Saudi Standards, Metrology and Quality Organization</publisher-name><publisher-loc>Riyadh, Saudi Arabia</publisher-loc><year>1982</year></citation></ref>
<ref id="b27-ijerph-07-02978"><label>27</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Matczak</surname><given-names>W</given-names></name><name><surname>Stanislawka</surname><given-names>MP</given-names></name></person-group><article-title>Determination of Fumes and their Elements from Flux Cored Arc Welding</article-title><source>Medycyna Pracy</source><year>2004</year><volume>55</volume><fpage>481</fpage><lpage>489</lpage><pub-id pub-id-type="pmid">15887517</pub-id></citation></ref>
<ref id="b28-ijerph-07-02978"><label>28</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Boelter</surname><given-names>FW</given-names></name><name><surname>Simmons</surname><given-names>CE</given-names></name><name><surname>Berman</surname><given-names>L</given-names></name><name><surname>Scheff</surname><given-names>P</given-names></name></person-group><article-title>Two–Zone Model Application to Breathing Zone and Area Welding Fume Concentration Data</article-title><source>J. Occup. Environ. Hyg</source><year>2009</year><volume>6</volume><fpage>298</fpage><lpage>306</lpage><pub-id pub-id-type="doi">10.1080/15459620902809895</pub-id><pub-id pub-id-type="pmid">19266377</pub-id></citation></ref>
<ref id="b29-ijerph-07-02978"><label>29</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rastogi</surname><given-names>SK</given-names></name><name><surname>Gupta</surname><given-names>BN</given-names></name><name><surname>Husain</surname><given-names>T</given-names></name><name><surname>Mathur</surname><given-names>N</given-names></name><name><surname>Srivastava</surname><given-names>S</given-names></name></person-group><article-title>Spirometric Abnormalities among Welders</article-title><source>Environ. Res</source><year>1991</year><volume>56</volume><fpage>15</fpage><lpage>24</lpage><pub-id pub-id-type="doi">10.1016/S0013-9351(05)80105-7</pub-id><pub-id pub-id-type="pmid">1915188</pub-id></citation></ref>
<ref id="b30-ijerph-07-02978"><label>30</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bowler</surname><given-names>RM</given-names></name><name><surname>Gysens</surname><given-names>S</given-names></name><name><surname>Diamond</surname><given-names>E</given-names></name><name><surname>Booty</surname><given-names>A</given-names></name><name><surname>Hartney</surname><given-names>C</given-names></name><name><surname>Roels</surname><given-names>HA</given-names></name></person-group><article-title>Neuropsychological Sequelae of Exposure to Welding Fumes in a Group of Occupationally Exposed Men</article-title><source>Int. J. Hyg. Environ. Health</source><year>2003</year><volume>206</volume><fpage>517</fpage><lpage>529</lpage><pub-id pub-id-type="doi">10.1078/1438-4639-00249</pub-id><pub-id pub-id-type="pmid">14626899</pub-id></citation></ref>
<ref id="b31-ijerph-07-02978"><label>31</label><citation citation-type="web"><person-group person-group-type="author"><name><surname>Wallace</surname><given-names>ME</given-names></name><name><surname>Fischbach</surname><given-names>T</given-names></name><name><surname>Kovein</surname><given-names>RJ</given-names></name></person-group><source>Control Technology Assessment for the Welding Operations at Boilermaker’s National Apprenticeship Training School Kansas City, Kansas</source><publisher-name>U.S. Department of Health and Human Services</publisher-name><year>1997</year><comment>Available online: <ext-link xlink:href="http://www.osha.gov/SLTC/weldingcuttingbrazing/report_boilermaker.html/" ext-link-type="uri">http://www.osha.gov/SLTC/weldingcuttingbrazing/report_boilermaker.html/</ext-link> (accessed on March 28, 2010)</comment></citation></ref>
<ref id="b32-ijerph-07-02978"><label>32</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bowler</surname><given-names>RM</given-names></name><name><surname>Roels</surname><given-names>HA</given-names></name><name><surname>Nakagawa</surname><given-names>S</given-names></name><name><surname>Drezgic</surname><given-names>M</given-names></name><name><surname>Diamond</surname><given-names>E</given-names></name><name><surname>Park</surname><given-names>R</given-names></name><name><surname>Koller</surname><given-names>W</given-names></name><name><surname>Bowler</surname><given-names>RP</given-names></name><name><surname>Mergler</surname><given-names>D</given-names></name><name><surname>Bouchard</surname><given-names>M</given-names></name><name><surname>Smith</surname><given-names>D</given-names></name><name><surname>Gwiazda</surname><given-names>R</given-names></name><name><surname>Doty</surname><given-names>RL</given-names></name></person-group><article-title>Dose-Effect Relationship between Manganese Exposure and Neurological Neuropsychological and Pulmonary Function in Confined Space Bridge Welders</article-title><source>J. Occup. Environ. Med</source><year>2007</year><volume>64</volume><fpage>167</fpage><lpage>177</lpage><pub-id pub-id-type="doi">10.1136/oem.2006.028761</pub-id></citation></ref>
<ref id="b33-ijerph-07-02978"><label>33</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Flynn</surname><given-names>MR</given-names></name><name><surname>Susi</surname><given-names>P</given-names></name></person-group><article-title>Manganese, Iron, and Total Particulate Exposures to Welders</article-title><source>J. Occup. Environ. Hyg</source><year>2010</year><volume>7</volume><fpage>115</fpage><lpage>126</lpage><pub-id pub-id-type="pmid">20013450</pub-id></citation></ref>
<ref id="b34-ijerph-07-02978"><label>34</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Santamaria</surname><given-names>AB</given-names></name><name><surname>Cushing</surname><given-names>CA</given-names></name><name><surname>Antonini</surname><given-names>JM</given-names></name><name><surname>Finley</surname><given-names>BL</given-names></name><name><surname>Mowat</surname><given-names>FS</given-names></name></person-group><article-title>State-of-the-Science Review: Does Manganese Exposure during Welding Pose a Neurological Risk?</article-title><source>J. Toxicol. Environ. Health B</source><year>2007</year><volume>10</volume><fpage>417</fpage><lpage>465</lpage><pub-id pub-id-type="doi">10.1080/15287390600975004</pub-id></citation></ref></ref-list>
<sec sec-type="display-objects">
<title>Tables</title>
<table-wrap id="t1-ijerph-07-02978" position="float">
<label>Table 1.</label>
<caption>
<p>Sizes of Work Places, Number of Workers and Electrode Types.</p></caption>
<table frame="box" rules="all">
<thead>
<tr>
<th align="left" valign="top"><bold>Factory No</bold></th>
<th align="left" valign="top"><bold>1</bold></th>
<th align="left" valign="top"><bold>2</bold></th>
<th align="left" valign="top"><bold>3</bold></th>
<th align="left" valign="top"><bold>4</bold></th>
<th align="left" valign="top"><bold>5</bold></th>
<th align="left" valign="top"><bold>6</bold></th></tr></thead>
<tbody>
<tr>
<td align="left" valign="top"><bold>Workplace size, m</bold><break/><bold>Volume, m<sup>3</sup></bold></td>
<td align="left" valign="top">64 × 25 × 9<break/>14,400</td>
<td align="left" valign="top">50 × 25 × 12<break/>15,000</td>
<td align="left" valign="top">114 × 72 × 12<break/>98,496</td>
<td align="left" valign="top">40 × 15 × 12<break/>72,000</td>
<td align="left" valign="top">152 × 45 × 4<break/>27,360</td>
<td align="left" valign="top">60 × 30 × 10<break/>18,000</td></tr>
<tr>
<td align="left" valign="top"><bold>Total Workers</bold></td>
<td align="left" valign="top">30</td>
<td align="left" valign="top">81</td>
<td align="left" valign="top">100</td>
<td align="left" valign="top">56</td>
<td align="left" valign="top">130</td>
<td align="left" valign="top">19</td></tr>
<tr>
<td align="left" valign="top"><bold>Welders</bold></td>
<td align="left" valign="top">12</td>
<td align="left" valign="top">10</td>
<td align="left" valign="top">35</td>
<td align="left" valign="top">20</td>
<td align="left" valign="top">80</td>
<td align="left" valign="top">6</td></tr>
<tr>
<td align="left" valign="top"><bold>Work Schedule (h)</bold><break/><bold>Break Periods (h)</bold></td>
<td align="left" valign="top">07:00–15:00<break/>12:00–13:00</td>
<td align="left" valign="top">06:00–17:00<break/>09:00–09:15<break/>12:30–13:00<break/>16:00–16.15</td>
<td align="left" valign="top">07.30–18:00<break/>10:00–10:15<break/>12:45–13:45</td>
<td align="left" valign="top">07:00–15.30<break/>10:00–10:30<break/>13:00–13:30</td>
<td align="left" valign="top">07:00–15:30<break/>12:30–13:00</td>
<td align="left" valign="top">07:00–16:00<break/>9:30–9:45<break/>12:30–13:00<break/>15:00–15:15</td></tr>
<tr>
<td align="left" valign="top"><bold>Electrode Type</bold></td>
<td align="left" valign="top">E7018</td>
<td align="left" valign="top">E7024,7018</td>
<td align="left" valign="top">E7018,7024</td>
<td align="left" valign="top">E6013</td>
<td align="left" valign="top">E7024</td>
<td align="left" valign="top">E7018</td></tr></tbody></table></table-wrap>
<table-wrap id="t2-ijerph-07-02978" position="float">
<label>Table 2</label>
<caption>
<p>Eight- hour Average Particulate Concentrations of Welding Fume.</p></caption>
<table frame="box" rules="cols">
<thead>
<tr>
<th align="center" valign="middle" rowspan="3"><bold>Sample No</bold></th>
<th colspan="6" align="center" valign="middle"><bold>Particulate Concentration (mg/m<sup>3</sup>)</bold></th></tr>
<tr>
<th valign="middle" align="left" colspan="7"><hr/></th></tr>
<tr>
<th align="center" valign="middle"><bold>Factory 1</bold></th>
<th align="center" valign="middle"><bold>Factory 2</bold></th>
<th align="center" valign="middle"><bold>Factory 3</bold></th>
<th align="center" valign="middle"><bold>Factory 4</bold></th>
<th align="center" valign="middle"><bold>Factory 5</bold></th>
<th align="center" valign="middle"><bold>Factory 6</bold></th></tr>
<tr>
<th valign="middle" align="left" colspan="7"><hr/></th></tr></thead>
<tbody>
<tr>
<td align="center" valign="top">1</td>
<td align="center" valign="top">11.0</td>
<td align="center" valign="top">4.0</td>
<td align="center" valign="top">13.0</td>
<td align="center" valign="top">6.0</td>
<td align="center" valign="top">9.5</td>
<td align="center" valign="top">3.5</td></tr>
<tr>
<td align="center" valign="top">2</td>
<td align="center" valign="top">15.5</td>
<td align="center" valign="top">3.0</td>
<td align="center" valign="top">4.5</td>
<td align="center" valign="top">6.0</td>
<td align="center" valign="top">2.0</td>
<td align="center" valign="top">2.5</td></tr>
<tr>
<td align="center" valign="top">3</td>
<td align="center" valign="top">5.0</td>
<td align="center" valign="top">10.5</td>
<td align="center" valign="top">17.0</td>
<td align="center" valign="top">5.5</td>
<td align="center" valign="top">4.0</td>
<td align="center" valign="top">2.5</td></tr>
<tr>
<td align="center" valign="top">4</td>
<td align="center" valign="top">5.0</td>
<td align="center" valign="top">7.5</td>
<td align="center" valign="top">4.0</td>
<td align="center" valign="top">6.0</td>
<td align="center" valign="top">3.0</td>
<td align="center" valign="top">3.0</td></tr>
<tr>
<td align="center" valign="top">5</td>
<td align="center" valign="top">5.5</td>
<td align="center" valign="top">5.0</td>
<td align="center" valign="top">7.0</td>
<td align="center" valign="top">4.5</td>
<td align="center" valign="top">10.5</td>
<td align="center" valign="top">2.0</td></tr>
<tr>
<td align="center" valign="top">6</td>
<td align="center" valign="top">4.0</td>
<td align="center" valign="top">5.0</td>
<td align="center" valign="top">24.0</td>
<td align="center" valign="top">8.0</td>
<td align="center" valign="top">13.0</td>
<td align="center" valign="top">1.5</td></tr>
<tr>
<td align="center" valign="top">7</td>
<td align="center" valign="top">5.0</td>
<td align="center" valign="top">3.5</td>
<td align="center" valign="top">3.0</td>
<td align="center" valign="top">7.0</td>
<td align="center" valign="top">1.5</td>
<td align="center" valign="top">4.5</td></tr>
<tr>
<td align="center" valign="top">8</td>
<td align="center" valign="top">8.0</td>
<td align="center" valign="top">7.0</td>
<td align="center" valign="top">3.0</td>
<td align="center" valign="top">12.0</td>
<td align="center" valign="top">1.0</td>
<td align="center" valign="top">3.5</td></tr>
<tr>
<td align="center" valign="top">9</td>
<td align="center" valign="top">2.0</td>
<td align="center" valign="top">4.0</td>
<td align="center" valign="top">13.5</td>
<td align="center" valign="top">8.0</td>
<td align="center" valign="top">1.0</td>
<td align="center" valign="top">3.5</td></tr>
<tr>
<td align="center" valign="top">10</td>
<td align="center" valign="top">2.0</td>
<td align="center" valign="top">3.5</td>
<td align="center" valign="top">24.0</td>
<td align="center" valign="top">5.0</td>
<td align="center" valign="top">1.5</td>
<td align="center" valign="top">3.5</td></tr></tbody></table></table-wrap>
<table-wrap id="t3-ijerph-07-02978" position="float">
<label>Table 3</label>
<caption>
<p>Eight Hour Average Metal Concentrations of Welding Fume In Each Factory.</p></caption>
<table frame="box" rules="all">
<thead>
<tr>
<th align="center" valign="middle" rowspan="2"><bold>Factory No.</bold></th>
<th colspan="4" align="center" valign="middle"><bold>Eight hour Average Particulate Concentration (mg/m<sup>3</sup>)</bold></th></tr>
<tr>
<th align="center" valign="middle"><bold>Total</bold></th>
<th align="center" valign="middle"><bold>Mn</bold></th>
<th align="center" valign="middle"><bold>Cu</bold></th>
<th align="center" valign="middle"><bold>Mo</bold></th></tr></thead>
<tbody>
<tr>
<td align="center" valign="top">1</td>
<td align="center" valign="top">5.0<break/>5.0<break/>4.0<break/>5.0</td>
<td align="center" valign="top">0.106<break/>0.116<break/>0.080<break/>0.142</td>
<td align="center" valign="top">0.002<break/>0.003<break/>0.001<break/>0.004</td>
<td align="center" valign="top">0.001<break/>0.001<break/>0.001<break/>0.001</td></tr>
<tr>
<td align="center" valign="top">2</td>
<td align="center" valign="top">5.0<break/>5.0<break/>3.5<break/>7.0</td>
<td align="center" valign="top">0.117<break/>0.062<break/>0.066<break/>0.184</td>
<td align="center" valign="top">0.002<break/>0.002<break/>0.001<break/>0.006</td>
<td align="center" valign="top">0.001<break/>0.001<break/>0.001<break/>0.001</td></tr>
<tr>
<td align="center" valign="top">3</td>
<td align="center" valign="top">17.0<break/>24.0<break/>13.5<break/>24.0</td>
<td align="center" valign="top">0.026<break/>0.477<break/>0.272<break/>0.091</td>
<td align="center" valign="top">0.001<break/>0.009<break/>0.059<break/>0.080</td>
<td align="center" valign="top">0.001<break/>0.002<break/>0.001<break/>0.001</td></tr>
<tr>
<td align="center" valign="top">4</td>
<td align="center" valign="top">8.0<break/>7.0<break/>12.0<break/>8.0</td>
<td align="center" valign="top">0.098<break/>0.085<break/>0.010<break/>0.129</td>
<td align="center" valign="top">0.002<break/>0.005<break/>0.003<break/>0.003</td>
<td align="center" valign="top">0.004<break/>0.002<break/>0.001<break/>0.058</td></tr>
<tr>
<td align="center" valign="top">5</td>
<td align="center" valign="top">9.5<break/>4.0<break/>10.5<break/>13.0</td>
<td align="center" valign="top">0.279<break/>0.088<break/>0.190<break/>0.280</td>
<td align="center" valign="top">0.022<break/>0.002<break/>0.002<break/>0.003</td>
<td align="center" valign="top">0.021<break/>0.001<break/>0.001<break/>0.001</td></tr>
<tr>
<td align="center" valign="top">6</td>
<td align="center" valign="top">3.5<break/>2.5<break/>4.5<break/>3.5</td>
<td align="center" valign="top">0.050<break/>0.187<break/>0.095<break/>0.082</td>
<td align="center" valign="top">0.002<break/>0.001<break/>0.001<break/>0.002</td>
<td align="center" valign="top">0.001<break/>0.003<break/>0.003<break/>0.001</td></tr></tbody></table></table-wrap></sec></back></article>