Next Article in Journal
Groundwater Vulnerability Assessment of the Pingtung Plain in Southern Taiwan
Next Article in Special Issue
A Technical Approach to the Evaluation of Radiofrequency Radiation Emissions from Mobile Telephony Base Stations
Previous Article in Journal
Is Green Exercise for All? A Descriptive Study of Green Exercise Habits and Promoting Factors in Adult Norwegians
Previous Article in Special Issue
An Overview of Sub-Cellular Mechanisms Involved in the Action of TTFields
Article Menu

Export Article

Open AccessArticle
Int. J. Environ. Res. Public Health 2016, 13(11), 1171; doi:10.3390/ijerph13111171

An Investigation on the Effect of Extremely Low Frequency Pulsed Electromagnetic Fields on Human Electrocardiograms (ECGs)

1
School of Engineering, RMIT University, Melbourne 3000, Victoria, Australia
2
Department of Biomedical Engineering, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China
3
The Fifth Affiliated Hospital of Southern Medical University, Guangzhou 510900, China
*
Author to whom correspondence should be addressed.
Academic Editor: Mats-Olof Mattssonto
Received: 28 June 2016 / Revised: 16 November 2016 / Accepted: 16 November 2016 / Published: 23 November 2016
View Full-Text   |   Download PDF [1155 KB, uploaded 23 November 2016]   |  

Abstract

For this investigation, we studied the effects of extremely low frequency pulse electromagnetic fields (ELF-PEMF) on the human cardiac signal. Electrocardiograms (ECGs) of 22 healthy volunteers before and after a short duration of ELF-PEMF exposure were recorded. The experiment was conducted under single-blind conditions. The root mean square (RMS) value of the recorded data was considered as comparison criteria. We also measured and analysed four important ECG time intervals before and after ELF-PEMF exposure. Results revealed that the RMS value of the ECG recordings from 18 participants (81.8% of the total participants) increased with a mean value of 3.72%. The increase in ECG voltage levels was then verified by a second experimental protocol with a control exposure. In addition to this, we used hyperbolic T-distributions (HTD) in the analysis of ECG signals to verify the change in the RR interval. It was found that there were small shifts in the frequency-domain signal before and after EMF exposure. This shift has an influence on all frequency components of the ECG signals, as all spectrums were shifted. It is shown from this investigation that a short time exposure to ELF-PEMF can affect the properties of ECG signals. Further study is needed to consolidate this finding and discover more on the biological effects of ELF-PEMF on human physiological processes. View Full-Text
Keywords: electrocardiograms (ECGs); extremely low frequency pulse electromagnetic fields (ELF-PEMF); time frequency analysis electrocardiograms (ECGs); extremely low frequency pulse electromagnetic fields (ELF-PEMF); time frequency analysis
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Fang, Q.; Mahmoud, S.S.; Yan, J.; Li, H. An Investigation on the Effect of Extremely Low Frequency Pulsed Electromagnetic Fields on Human Electrocardiograms (ECGs). Int. J. Environ. Res. Public Health 2016, 13, 1171.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Int. J. Environ. Res. Public Health EISSN 1660-4601 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top