Next Article in Journal
Lightweight Active Object Retrieval with Weak Classifiers
Next Article in Special Issue
Detection of Antibiotics and Evaluation of Antibacterial Activity with Screen-Printed Electrodes
Previous Article in Journal
Data Summarization in the Node by Parameters (DSNP): Local Data Fusion in an IoT Environment
Previous Article in Special Issue
Integrated Affinity Biosensing Platforms on Screen-Printed Electrodes Electrografted with Diazonium Salts
Article Menu
Issue 3 (March) cover image

Export Article

Open AccessArticle
Sensors 2018, 18(3), 800; https://doi.org/10.3390/s18030800

Electrochemical Sensor for Bilirubin Detection Using Screen Printed Electrodes Functionalized with Carbon Nanotubes and Graphene

Nanophotonics and Metrology Laboratory (NAM), Swiss Federal Institute of Technology Lausanne (EPFL), 1015 Lausanne, Switzerland
*
Author to whom correspondence should be addressed.
Received: 6 February 2018 / Revised: 5 March 2018 / Accepted: 6 March 2018 / Published: 7 March 2018
(This article belongs to the Special Issue Screen-Printed Electrodes)
View Full-Text   |   Download PDF [3507 KB, uploaded 7 March 2018]   |  

Abstract

Practice oriented point-of-care diagnostics require easy-to-handle, miniaturized, and low-cost analytical tools. In a novel approach, screen printed carbon electrodes (SPEs), which were functionalized with nanomaterials, are employed for selective measurements of bilirubin, which is an important biomarker for jaundice. Multi-walled carbon nanotubes (MWCNT) and graphene separately deposited on SPEs provide the core of an electrochemical sensor for bilirubin. The electrocatalytic activity towards bilirubin oxidation (bilirubin to biliverdin) was observed at +0.25 V. In addition, a further peak corresponding to the electrochemical conversion of biliverdin into purpurin appeared at +0.48 V. When compared to MWCNT, the graphene type shows a 3-fold lower detection limit (0.3 ± 0.022 nM and 0.1 ± 0.018 nM, respectively), moreover, the graphene type exhibits a larger linear range (0.1–600 µM) than MWCNT (0.5–500 µM) with a two-fold better sensitivity, i.e., 30 nA µM−1 cm−2, and 15 nA µM−1 cm−2, respectively. The viability is validated through measurements of bilirubin in blood serum samples and the selectivity is ensured by inhibiting common interfering biological substrates using an ionic nafion membrane. The presented approach enables the design and implementation of low cost and miniaturized electrochemical sensors. View Full-Text
Keywords: screen printed electrode (SPE); bilirubin; electrochemical sensor; carbon nanotubes (CNT); graphene; nanomaterials; electrochemical analysis screen printed electrode (SPE); bilirubin; electrochemical sensor; carbon nanotubes (CNT); graphene; nanomaterials; electrochemical analysis
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).
SciFeed

Share & Cite This Article

MDPI and ACS Style

Thangamuthu, M.; Gabriel, W.E.; Santschi, C.; Martin, O.J.F. Electrochemical Sensor for Bilirubin Detection Using Screen Printed Electrodes Functionalized with Carbon Nanotubes and Graphene. Sensors 2018, 18, 800.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Sensors EISSN 1424-8220 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert