<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="en" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Sensors</journal-id>
<journal-title>Sensors</journal-title>
<issn pub-type="epub">1424-8220</issn>
<publisher>
<publisher-name>Molecular Diversity Preservation International (MDPI)</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3390/s120607080</article-id>
<article-id pub-id-type="publisher-id">sensors-12-07080</article-id>
<article-categories>
<subj-group>
<subject>Article</subject></subj-group></article-categories>
<title-group>
<article-title>Quartz Crystal Microbalance Aptasensor for Sensitive Detection of Mercury(II) Based on Signal Amplification with Gold Nanoparticles</article-title></title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Dong</surname><given-names>Zong-Mu</given-names></name><xref ref-type="aff" rid="af1-sensors-12-07080"><sup>1</sup></xref></contrib>
<contrib contrib-type="author">
<name><surname>Zhao</surname><given-names>Guang-Chao</given-names></name><xref ref-type="aff" rid="af1-sensors-12-07080"><sup>1</sup></xref><xref ref-type="aff" rid="af2-sensors-12-07080"><sup>2</sup></xref><xref ref-type="corresp" rid="c1-sensors-12-07080"><sup>*</sup></xref></contrib></contrib-group>
<aff id="af1-sensors-12-07080">
<label>1</label> College of Environmental Science and engineering, Anhui Normal University, Wuhu 241000, China; E-Mail: <email>dzongmu@mail.ahnu.edu.cn</email></aff>
<aff id="af2-sensors-12-07080">
<label>2</label> Anhui Key Laboratory of Chem-Biosensing, School of Chemistry and Materials Science, Anhui Normal University, Wuhu 241000, China</aff>
<author-notes>
<corresp id="c1-sensors-12-07080">
<label>*</label>Author to whom correspondence should be addressed; E-Mail: <email>gczhao@mail.ahnu.edu.cn</email>; Tel.: +86-55-3591-0721; Fax: +86-55-3591-0720.</corresp></author-notes>
<pub-date pub-type="collection">
<year>2012</year></pub-date>
<pub-date pub-type="epub">
<day>29</day>
<month>05</month>
<year>2012</year></pub-date>
<volume>12</volume>
<issue>6</issue>
<fpage>7080</fpage>
<lpage>7094</lpage>
<history>
<date date-type="received">
<day>18</day>
<month>04</month>
<year>2012</year></date>
<date date-type="rev-recd">
<day>14</day>
<month>05</month>
<year>2012</year></date>
<date date-type="accepted">
<day>23</day>
<month>05</month>
<year>2012</year></date></history>
<permissions>
<copyright-statement>© 2012 by the authors; licensee MDPI, Basel, Switzerland.</copyright-statement>
<copyright-year>2012</copyright-year>
<license>
<p>This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).</p></license></permissions>
<abstract>
<p>We show that a short mercury-specific aptamer (MSA) along with gold nanoparticles (Au-NPs) can be used to determine Hg(II) ion by a combination of a QCM-based sensor and a flow system. The MSA binds specifically to Hg(II), and the Au-NPs can amplify the signal to enhance sensitivity. Specifically, the short thiolated MSAs are immobilized on the surface of the QCM as the capture probe, and the MSAs are linked to the Au-NPs as the linking probe. The two components can form a sandwich structure of the T-Hg(II)-T type in the presence of Hg(II) ions. This leads to change in the mass on the QCM and a change in the resonance frequency. Hg(II) can be determined with a detection limit of 0.24 ± 0.06 nM which is better by three orders of magnitude than previous methods. The sensor can be regenerated by disrupting the T-Hg(II)-T base pairs with a solution of cysteine.</p></abstract>
<kwd-group>
<kwd>mercury ion</kwd>
<kwd>aptamer</kwd>
<kwd>gold nanoparticle</kwd>
<kwd>quartz crystal microbalance</kwd>
<kwd>flow system</kwd></kwd-group></article-meta></front>
<body>
<sec sec-type="intro">
<label>1.</label>
<title>Introduction</title>
<p>Mercury is a highly toxic heavy metal ion that exists in metallic, inorganic, and organic forms [<xref ref-type="bibr" rid="b1-sensors-12-07080">1</xref>]. Solvated mercuric ion (Hg<sup>2+</sup>), one of the inorganic forms of mercury, mostly exists in surface water due to its high water solubility and high stability, which can be ingested by aquatic life and eventually enters human beings through the food chain [<xref ref-type="bibr" rid="b2-sensors-12-07080">2</xref>]. As a toxic ion, Hg<sup>2+</sup> can cause the disruption of cell membranes [<xref ref-type="bibr" rid="b3-sensors-12-07080">3</xref>], the impairment of mitochondrial function [<xref ref-type="bibr" rid="b4-sensors-12-07080">4</xref>], and the inhibition of DNA replication in a cell [<xref ref-type="bibr" rid="b5-sensors-12-07080">5</xref>]. Therefore, it is critical to determine and quantify Hg<sup>2+</sup> under aqueous conditions with high sensitivity and selectivity.</p>
<p>Indeed, there are numerous reports on Hg<sup>2+</sup> detection by using Hg<sup>2+</sup>-sensitive fluorophores or chromophores [<xref ref-type="bibr" rid="b6-sensors-12-07080">6</xref>–<xref ref-type="bibr" rid="b8-sensors-12-07080">8</xref>]. Recently, the aptamer-based Hg<sup>2+</sup> detection assays, which use the coordinate interaction between thymine (T) and Hg<sup>2+</sup>, have attracted significant interest. Aptamers are nucleic acid-based (DNA or RNA) affinity probes, which can provide the conjugate interaction between Hg<sup>2+</sup> and thymine [<xref ref-type="bibr" rid="b9-sensors-12-07080">9</xref>–<xref ref-type="bibr" rid="b11-sensors-12-07080">11</xref>]. Based on this, several novel Hg<sup>2+</sup> detection assays in aqueous media have been developed [<xref ref-type="bibr" rid="b12-sensors-12-07080">12</xref>–<xref ref-type="bibr" rid="b17-sensors-12-07080">17</xref>]. For example, a fluorescence resonance energy transfer (FRET) sensor for Hg<sup>2+</sup> was designed by using a mercury-specific aptamer (MSA) probe labeled with fluorophore/quencher units [<xref ref-type="bibr" rid="b16-sensors-12-07080">16</xref>]. MSA modified gold nanoparticles (Au-NPs) were also employed as a colorimetric probe [<xref ref-type="bibr" rid="b17-sensors-12-07080">17</xref>], optical probe [<xref ref-type="bibr" rid="b18-sensors-12-07080">18</xref>], surface enhanced raman spectroscopy (SERS) [<xref ref-type="bibr" rid="b19-sensors-12-07080">19</xref>], surface plasmon resonance (SPR) spectra probe [<xref ref-type="bibr" rid="b20-sensors-12-07080">20</xref>] and electrochemical probe for Hg<sup>2+</sup> [<xref ref-type="bibr" rid="b12-sensors-12-07080">12</xref>,<xref ref-type="bibr" rid="b15-sensors-12-07080">15</xref>]. In addition, conjugating polymers [<xref ref-type="bibr" rid="b21-sensors-12-07080">21</xref>] and DNAzymes [<xref ref-type="bibr" rid="b22-sensors-12-07080">22</xref>–<xref ref-type="bibr" rid="b24-sensors-12-07080">24</xref>] were also exploited to couple with MSA for Hg<sup>2+</sup> detection. Because of the specific interaction between Hg<sup>2+</sup> and thymine, these assays have a satisfying selectivity. However, most of these approaches rely on labels or multiple washing steps [<xref ref-type="bibr" rid="b25-sensors-12-07080">25</xref>]. Furthermore, fluorescence-based aptasensors suffer from stability and photobleaching of fluorophores. On the other hand, electrochemical-based aptasensor must be labeled with redox species that are employed as signal transducers [<xref ref-type="bibr" rid="b26-sensors-12-07080">26</xref>,<xref ref-type="bibr" rid="b27-sensors-12-07080">27</xref>]. Label-free monitoring of biorecognition events provides a promising platform, which is simple, cost-effective, and requires no external modification on the biomolecules. The QCM-based sensor is one of the promising candidates for the development of label-free sensors.</p>
<p>A QCM is an acoustic sensor based on a piezoelectric crystal. The characteristics of QCM-based sensors have been described by Sauerbrey [<xref ref-type="bibr" rid="b28-sensors-12-07080">28</xref>]. The sensor is sensitive and allows for noninvasive on-line measurements of adsorption and biophysical changes. However, it is well known that the signal response of QCM-based assays is unstable when the target concentration in a sample is very low, which results in low sensitivity and dissatisfactory reproducibility. Moreover, the contaminating molecule that nonspecifically binds to the QCM surface can conspicuously interfere with the QCM-based assay. In order to respond to the challenges, we designed a QCM-based sensor, in which an aptamer was combined to QCM surface to improve the selectivity and Au-NPs were used as an amplifier for the amplification of QCM signal to increase the sensitivity.</p>
<p>As shown in <xref ref-type="fig" rid="f8-sensors-12-07080">Scheme 1</xref>, a short thiolated MSA is immobilized on the QCM electrode surface as the capturing probe, and the MSA linked gold nanoparticles is used as the linking probe in solutions. Subsequently, in the presence of Hg<sup>2+</sup>, they can form sandwich structural T-Hg<sup>2+</sup>-T base pairs through the Hg<sup>2+</sup> mediated coordination. Consequently, the use of Au-NPs can amplify the detection signal, which enhances the sensitivity for the QCM-based assay. Furthermore, because of the strong binding with Hg<sup>2+</sup> [<xref ref-type="bibr" rid="b29-sensors-12-07080">29</xref>], cysteine can disrupt the T-Hg<sup>2+</sup>-T sandwich structure, and therefore the designed QCM-based sensor can be regenerated in cysteine solution and be reused for multiple times. Particularly, by combining the QCM-based sensor with a flow injection system [<xref ref-type="bibr" rid="b30-sensors-12-07080">30</xref>], the continuous and repeated assay of mercury can be realized easily.</p></sec>
<sec>
<label>2.</label>
<title>Experimental</title>
<sec>
<label>2.1.</label>
<title>Reagents and Instruments</title>
<p>The mercury-specific aptamer was synthesized by Shanghai Kehua Bio-Engineering Co. Ltd. (Shanghai, China). The sequence was HS-5′-(CH<sub>2</sub>)<sub>6</sub>-TTTT-3′. 6-Mercapto-1-hexanol, HAuCl<sub>4</sub>, cysteine, hexaammineruthenium(III) chloride, potassium ferricyanide and tris(2-carboxyethyl)phosphine hydrochloride (TCEP) ware purchased from Aldrich (St. Louis, MO, USA) and used as received. Hg<sup>2+</sup> stock solution (0.1 M) was prepared by dissolving HgCl<sub>2</sub> with 0.5% HNO<sub>3</sub> [<xref ref-type="bibr" rid="b12-sensors-12-07080">12</xref>]. The Hg<sup>2+</sup> stock solution was diluted to desired concentration with 0.05 M Tris-HCl buffer (pH 7.4) containing 0.1 M NaCl. All other reagents were of analytical grade and used without further purification. 0.05 M Tris-HCl buffer (pH 7.4) and 0.1 M phosphate buffered saline (PBS) (pH 7.4) were prepared according to standard procedures. All solutions were prepared with Milli-Q water (&gt;18.2 MΩ·cm<sup>−1</sup>).</p>
<p>The QCM was performed on a CHI 440A quartz crystal microbalance electrochemical workstation (Shanghai Chenhua Ltd., Shanghai, China). A 7.995 MHz AT-cut quartz crystal (13.7 mm diameter) covered with gold electrodes (Φ 5 mm) was mounted levelly in a homemade Taflon holder. This Taflon holder was linked with a six-channel BT100K peristaltic pump.</p>
<p>The scanning electron microscopy (SEM) images used to characterize the morphology of the QCM electrode surface were obtained on an S-4800 microscope (Hitachi Ltd., Tokyo, Japan). Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were carried out with a CHI660c electrochemical workstation (Shanghai Chenhua Ltd., Shanghai, China). CV and EIS were performed in 5 mM [Fe(CN)<sub>6</sub>]<sup>3−/4−</sup> solution which was purged with highly purified nitrogen at least 5 min. All the measurements were carried out at room temperature.</p></sec>
<sec>
<label>2.2.</label>
<title>Direct Immobilization of the Mercury-Specific Aptamer Capturing Probe on QCM Electrode</title>
<p>The QCM gold electrodes were cleaned with phiranha solution [H<sub>2</sub>O<sub>2</sub>/H<sub>2</sub>SO<sub>4</sub> 1:3 (v/v)] for 1 min, rinsed with copious amounts of purified water and ethanol, and dried with a gentle flow of nitrogen in order to remove grease and other pollutants from the electrode surface. Prior to the immobilization of the electrodes, aptamer stock solution (0.1 mM) was reduced in 10 mM TCEP for 2 h to cleave disulfide bonds. The resulting solution was then diluted with Tris-HCl buffer (pH 7.4) to the desired concentration (from 0.5 to 50 μM). Then, the QCM electrode was incubated in the aptamer solution for 16 h in the dark at 4 °C. Following incubation, the electrode was rinsed with water and then immersed in an aqueous solution of 1 mM 6-mercapto-1-hexanol for 1 h to passivate the electrode surface [<xref ref-type="bibr" rid="b31-sensors-12-07080">31</xref>]. As a final step, the electrode was rinsed with water, dried with nitrogen, and stored at 4 °C prior to use.</p></sec>
<sec>
<label>2.3.</label>
<title>Preparation of the Mercury-Specific Aptamer Linked with Au-NPs</title>
<p>Au-NPs were prepared according to a previously reported method with a slight modification [<xref ref-type="bibr" rid="b32-sensors-12-07080">32</xref>,<xref ref-type="bibr" rid="b33-sensors-12-07080">33</xref>]. In detail, solutions of HAuCl<sub>4</sub> and trisodium citrate were filtered through a 0.8 μm microporous membrane filter prior to use. 1% Trisodium citrate (2.5 mL) was added to boiling 0.25 mM HAuCl<sub>4</sub> solution (50 mL) and stirred for 10 min at the boiling point. The resulting solution was allowed to cool to room temperature. Concentration of the as-prepared Au-NPs was determined by UV-vis spectroscopy using Lambert-Beer's law (molar extinction coefficient of Au-NPs is 2.7 × 10<sup>8</sup> M<sup>−1</sup>·cm<sup>−1</sup> at λ<sub>520</sub>) [<xref ref-type="bibr" rid="b34-sensors-12-07080">34</xref>]. The as-prepared Au-NPs were further co-modified with the MSA probe. Briefly, Au-NPs (5 mL, 50 nM) was incubated with a MSA probe (100 μL, 100 μM) for 16 h at room temperature. The final mixture was slowly brought up to a final salt concentration of 0.1 M NaCl, 10 mM TCEP, 1 mM 6-mercapto-1-hexanol and 10 mM PBS (pH 7.4) and allowed to age for 40 h. Centrifugation was performed at 14,000 rpm for 40 min in order to remove excessive MSA. The precipitate was washed with 0.1 M NaCl, 10 mM PBS buffer (pH 7.4) solution, recentrifuged, and finally dispersed in 10 mM Tris-HCl buffer (pH 7.4) containing 0.3 M NaCl for the further use. The as-prepared MSA-(Au-NPs) was denoted as the linking probe 2. In control experiment, the original MSA was denoted as linking probe 1.</p></sec></sec>
<sec sec-type="results|discussion">
<label>3.</label>
<title>Results and Discussion</title>
<sec>
<label>3.1.</label>
<title>Characterization of the Sensing Interface</title>
<p>The principle of the sensor is based on the mass change on the sensing interface. In order to obtain the sensing signal, the designed aptamer must be first immobilized on the sensing interface as a capturing probe. Then, in the presence of Hg<sup>2+</sup>, a sandwich structure between the capturing probe and the linking probe is formed through the Hg<sup>2+</sup> mediated T-Hg<sup>2+</sup>-T base pairs. SEM was used to characterize the sandwich structure on formed the sensing interface. <xref ref-type="fig" rid="f1-sensors-12-07080">Figure 1</xref> shows SEM images of different interfaces after hybridizing in 0.5 μM Hg<sup>2+</sup> solution. <xref ref-type="fig" rid="f1-sensors-12-07080">Figure 1(A)</xref> is a bare electrode surface. <xref ref-type="fig" rid="f1-sensors-12-07080">Figure 1(B)</xref> is the sensing interface after hybridization between the capturing probe and linking probe 1. In contrast, <xref ref-type="fig" rid="f1-sensors-12-07080">Figure 1(C)</xref> is the interface after hybridization between the capturing probe and linking probe 2. Comparing <xref ref-type="fig" rid="f1-sensors-12-07080">Figure 1(C) with 1(B)</xref>, it is obvious that a large number of Au-NPs were successfully linked on the sensing interface through linking probe 2, which would result in a larger mass change on the QCM-based sensor in the same Hg<sup>2+</sup> solution. Therefore, the frequency response (Δf) should remarkably increase compared with using linking probe 1. Consequently, the sensitivity of the QCM-based Hg<sup>2+</sup> sensor can be significantly improved by using Au-NPs as the signal amplifier. In addition, electrochemical techniques including CV and EIS were utilized to characterize the steps of modified electrode and sensing for Hg<sup>2+</sup>. The results were shown in <xref ref-type="fig" rid="f9-sensors-12-07080">Figure S1</xref>–<xref ref-type="fig" rid="f10-sensors-12-07080">S2</xref> in supplement information. The electrochemical data also demonstrate that the sensor was successfully prepared.</p></sec>
<sec>
<label>3.2.</label>
<title>The Response of QCM-Based Sensor to Hg<sup>2+</sup></title>
<p>All QCM experiments were performed in a QCM cell, in which the quartz crystal Au electrodes were modified with the capturing probe. The device for Hg<sup>2+</sup> detection is presented in supplement information as <xref ref-type="fig" rid="f11-sensors-12-07080">Figure S3</xref>. The experimental process can be described as follows: 10 mM Tris-HCl buffer (pH 7.4) containing 0.1 M NaCl was injected firstly into the QCM cell with a flow rate of 20 μL/min and the crystal frequency was then measured as a background signal. After the signal change is less than 1 Hz of drift in 60 s, the experiment can be continued. 1 μM linking probe (1 or 2) solution was followed at a flow rate of 20 μL·min<sup>−1</sup> and the signal (ΔF) of the QCM-based sensor was recorded. The response of the sensor to Hg<sup>2+</sup> was shown in <xref ref-type="fig" rid="f2-sensors-12-07080">Figure 2</xref>. As can be seen in the a-b sections of <xref ref-type="fig" rid="f2-sensors-12-07080">Figure 2</xref>, this step was stopped after 600 s, Then, Hg<sup>2+</sup> was injected into the QCM cell by using micro-injector and the solution in QCM cell was remained to quiet until a stable signal (ΔF) was obtained (typically, about 900 s). In this process, Hg<sup>2+</sup> was captured with a sandwich structure, T-Hg<sup>2+</sup>-T, formed through the capturing probe, Hg<sup>2+</sup> and linking probe (1 or 2). This step provided a readout signal and frequency change for quantitative detection of mercury ions, as shown in the b-c sections of <xref ref-type="fig" rid="f2-sensors-12-07080">Figure 2</xref>. Subsequently, 10 mM Tris-HCl buffer (pH 7.4) containing 50 mM cysteine was followed at a flow rate of 25 μL·min<sup>−1</sup>. In this step, the sandwich structure T-Hg<sup>2+</sup>-T was dissociated and Hg<sup>2+</sup> was released from the sensing interface. Such that, the signal of the sensor recovered gradually to the level before Hg<sup>2+</sup> was injected (c-d sections of <xref ref-type="fig" rid="f2-sensors-12-07080">Figure 2</xref>), indicating that the sensing interface of sensor has been renewed. The regenerated sensor could be reused again and the above process could be repeated continuously. This strategy provides a facility for the continuous determination of Hg<sup>2+</sup>.</p></sec>
<sec>
<label>3.3.</label>
<title>Amplification Effect of Au-NPs</title>
<p>As a highly sensitive mass sensor, the QCM signal depends on the mass change on its sensing interface. For the same amount of target, if the mass change on the sensing interface can be increased greatly, the sensitivity of detection should be improved remarkably. In this work, Hg<sup>2+</sup> was detected through a specific sandwich structure formed by the capturing probe, Hg<sup>2+</sup> and the linking probe, which caused the mass change on the sensing interface [<xref ref-type="bibr" rid="b35-sensors-12-07080">35</xref>]. Au-NP was employed to link to the linking probe to get much more mass change on the sensing interface.</p>
<p><xref ref-type="fig" rid="f3-sensors-12-07080">Figure 3</xref> shows the response curves of the QCM-based sensor to different concentrations of Hg<sup>2+</sup>. As shown in <xref ref-type="fig" rid="f3-sensors-12-07080">Figure 3(A)</xref>, without linking probe, no frequency change (Δf) can be observed. In <xref ref-type="fig" rid="f3-sensors-12-07080">Figure 3(B)</xref>, an obvious Δf can be detected due to the use of linking probe 1. When linking probe 2 was used instead of linking probe 1, the response signal, Δf, increases greatly, about 15.2-fold under the same Hg<sup>2+</sup> concentration, as shown in <xref ref-type="fig" rid="f3-sensors-12-07080">Figure 3(C)</xref>. Since a large mass of Au-NP was immobilized on the linking probe, an amount of Au-NPs were loaded on the sensing interface through the formation of the sandwich structure, which led to more mass change on the sensing interface, as shown in <xref ref-type="fig" rid="f1-sensors-12-07080">Figure 1(C)</xref>. Thus, the detected signal was greatly amplified by the Au-NPs.</p></sec>
<sec>
<label>3.4.</label>
<title>Effects of Capturing Probe Density on Sensor Performance</title>
<p>The sensitivity of the QCM-based sensor is dependent on the amount of sandwich structures formed under the same Hg<sup>2+</sup> concentration, which depends in turn on the surface density of capturing probe molecules on the sensor surface. The dependence of the sensor signal on the surface density of capturing probe in same Hg<sup>2+</sup> solution is depicted in <xref ref-type="fig" rid="f4-sensors-12-07080">Figure 4</xref>, which shows that a low sensor sensitivity was obtained when a low density of capturing probe was used. The sensitivity of the sensor increases with the increase of density of the capturing probe. When the density reached about 3.25 nmol·cm<sup>−2</sup>, the response signal reaches the maximum, which is ascribed to the saturation of immobilized capturing probe on the sensor surface (the surface density was calculated on the basis of the Δf measured during QCM experiments) [<xref ref-type="bibr" rid="b36-sensors-12-07080">36</xref>,<xref ref-type="bibr" rid="b37-sensors-12-07080">37</xref>]. The surface density of capturing probe molecules on the sensor surface was also calculated to be 3.75 × 10<sup>14</sup> molecules·cm<sup>−2</sup> by Tarlov's electrochemical method [<xref ref-type="bibr" rid="b31-sensors-12-07080">31</xref>]. This value is less than 3.25 nmol·cm<sup>−2</sup> (1.96 × 10<sup>15</sup> molecules·cm<sup>−2</sup>) by the QCM method. The surface density of probe calculated by QCM may also contain contributions from the thimbleful of adsorbed water on the sensor surface. Compared with other reports employing hairpin aptamer ((6.57 ± 0.55) × 10<sup>13</sup> molecules·cm<sup>−2</sup>) [<xref ref-type="bibr" rid="b38-sensors-12-07080">38</xref>], the surface density of our sensor is larger, which is likely attributable to the use of short apatmers (only containing four thymines). The high surface density should greatly improve the sensitivity of the sensor and significantly reduce nonspecific adsorption and contaminant trapping.</p></sec>
<sec>
<label>3.5.</label>
<title>Sensitivity, Specificity and Reusability of the QCM-Based Sensor</title>
<p>As shown in <xref ref-type="fig" rid="f3-sensors-12-07080">Figure 3(C)</xref>, with the increase of Hg<sup>2+</sup> concentration, the response signal of the sensor (Δf) obviously increases. As a result, the relationship between the response signal and the Hg<sup>2+</sup> concentration can be established. Under the optimal conditions in which linking probe 2 was used, a linear relationship between the response signal Δf and Hg<sup>2+</sup> concentrations was obtained (shown in an inset of <xref ref-type="fig" rid="f5-sensors-12-07080">Figure 5</xref>). The Δf increased linearly with Hg<sup>2+</sup> concentrations in the tested range from 0.5 nM to 100 nM. According to the experimental data, a linear equation could be calculated: Δf = 1.82C + 1.60 (C is the concentration of the target Hg<sup>2+</sup>, 10<sup>−9</sup> M; Δf is the signal of sensor, Hz) with a relationship coefficient of 0.9986. The detection limit was evaluated to be 0.24 ± 0.06 nM. Under the same conditions expect for the using of Au-NPs as amplifier, in which linking probe 1 was used, the detection limit was about 0.3 μM. The detection limit for Hg<sup>2+</sup> detection was increased remarkably, about three orders of magnitude, by using Au-NPs as amplifier. Compared with data reported in the literature for other aptamer-based Hg<sup>2+</sup> sensors, the detection limit in this work was lower. <xref ref-type="table" rid="t1-sensors-12-07080">Table 1</xref> summarizes the sensitivity reported for several aptamer-based Hg<sup>2+</sup> sensors. The present Au-NPs amplification strategy reveals a superior sensitivity as compared to protocols of aptamer-based Hg<sup>2+</sup> sensors. It is clear that the detection limit is dependent on the sensitivity of assay and the stability of detecting signal. The lower detection limit suggests that both sensitivity and stability of the sensor have improved when Au-NP was used as the amplifier.</p>
<p>In the present work, a short ss-DNA containing only four thymine (T) bases was designed as an aptamer to selectively capture Hg<sup>2+</sup>, which can selectively and strongly bind Hg<sup>2+</sup> and form a stable ds-DNA through metal-mediated T-Hg<sup>2+</sup>-T structure. To investigate the specificity of the designed QCM-based sensor, we also challenged this sensor with nine interference ions: Ca<sup>2+</sup> and Mg<sup>2+</sup> (0.5 mM, each), Cu<sup>2+</sup>, Cd<sup>2+</sup>, Pb<sup>2+</sup>, Zn<sup>2+</sup>, Ni<sup>2+</sup> and Ag<sup>+</sup>(0.5 μM, each), Au<sup>3+</sup>(0.1 μM). <xref ref-type="fig" rid="f6-sensors-12-07080">Figure 6</xref> depicts the signal response of the sensor to the above mentioned ions. Compared with the significant frequency change (12 Hz) of 5 nM Hg<sup>2+</sup>, the 100-fold or higher concentrations other interference ions, except for Au<sup>3+</sup>, only produced a slight frequency change (&lt;2 Hz), suggesting that the present sensor has highly selectivity owing to the specific coordination between T bases and Hg<sup>2+</sup> ions. However, the interference of Au<sup>3+</sup> was noted to be relatively great than that of other common metal ions.</p>
<p>Compared to antibody-based affinity biosensors, aptamer-based sensors provide an advantage of chemical stability [<xref ref-type="bibr" rid="b11-sensors-12-07080">11</xref>]. The chemical stability of aptamer ensures that the sensor can be regenerated under proper conditions. In this work, the sensor was regenerated with 50 mM cysteine solution, because the sandwich structure of T-Hg<sup>2+</sup>-T can be disrupted by cysteine. The sensor was firstly challenged with 5 nM Hg<sup>2+</sup> to obtain a response signal. Then, the sensor was washed with a flowing cysteine solution and the signal of blank solution was determined again. The above procedure was repeated continuously for 10 times and the results were presented in <xref ref-type="fig" rid="f7-sensors-12-07080">Figure 7</xref>.</p>
<p>The data suggested that the response signal to the same concentration Hg<sup>2+</sup> only attenuates about 5.7% after 10 cycles and the blank signal almost remains unchanged, implying that the sensor can be regenerated and reused at least 10 times. In addition, when the sensor was stored in pH 7.4 Tris-HCl buffer at 4 °C, 97% and 91% response signal are retained after 7 days and 15 days, respectively. Linking probe 2 is also stable within 15 days when it is stored in pH 7.4 Tris-HCl buffer at −10 °C.</p></sec>
<sec>
<label>3.6.</label>
<title>Detection of Hg<sup>2+</sup> in Real Samples</title>
<p>To validate the application of our sensor in real water samples, it was used to determine the levels of Hg<sup>2+</sup> in waste and tap water samples. Prior to water sample analysis, the waste water samples were filtered through a 0.45 μm membrane. As described in the earlier section, 50 μL of waste water or tap water spiked with different concentration of Hg<sup>2+</sup> was injected into the QCM cell. The concentration of Hg<sup>2+</sup> was determined by applying the standard curve method and the results were summarized in <xref ref-type="table" rid="t2-sensors-12-07080">Table 2</xref>. It can be seen that mean recoveries range between 96.8% and 101.6% with relative standard deviations under 4.2%. The results indicate that the QCM-based sensor was highly accurate, precise, and reproducible, and can be used for the direct analysis of traces of mercury in real samples.</p></sec></sec>
<sec sec-type="conclusions">
<label>4.</label>
<title>Conclusions</title>
<p>The main advantage of the proposed QCM-based sensor is that it is label-free, which provides great simplicity for the construction of a biosensor, although the sensitivity and stability of the detected signal need further improvement. In this work, a sensitive QCM-based sensor for selective detection of Hg<sup>2+</sup> was constructed by using Au-NPs as the signal amplifier. Compared with sensors prepared without a signal amplifier, our sensor displayed about three orders of magnitude increase in the detection limit. By combining with flow injection and the regeneration, Hg<sup>2+</sup> can be continuously determined with a low detection limit of 0.24 nM. This strategy could also be used for constructing other QCM-based sensors for various targets. Due to its label-free nature, the constructed sensor should be applied conveniently in different fields.</p></sec></body>
<back>
<ack>
<p>This work was supported by the National Natural Science Foundation of China (20975001), the Educational Administration of Anhui Province (kj2010b354) and the Innovation Funds of Anhui Normal University (2010cxji16).</p></ack>
<app-group>
<app id="app1">
<title>Appendix</title>
<sec>
<title>CV and EIS Characterizations of Sensing Interface</title>
<p>Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were utilized to characterize the steps of modified electrode and sensing for Hg<sup>2+</sup>. At bare Au electrode, a couple of well redox peaks of [Fe(CN)<sub>6</sub>]<sup>4−/3−</sup> can be observed, as shown in <xref ref-type="fig" rid="f9-sensors-12-07080">Figure S1(a)</xref>. Then, the Au electrode was incubated in an aptamer solution for 16 h. Following incubation, the electrode was washed with water and immersed in an aqueous solution of 1mM mercaptoacetic acid for 1 h to remove nonspecifically adsorbed aptamer molecules and to passivate the electrode surface. Subsequently, the Au electrode immobilized with MSA and MCA was used as a work electrode and CV experiment was performed in the same [Fe(CN)<sub>6</sub>]<sup>4−/3−</sup> solution. As shown in <xref ref-type="fig" rid="f9-sensors-12-07080">Figure S1(b)</xref>, the peak currents obviously decreases and the difference between cathodic and anodic peak potential increases. The negative charge of MSA and mercaptoacetic acid on electrode surface prohibited the electron transfer of [Fe(CN)<sub>6</sub>]<sup>4−/3−</sup> at electrode interface. Following this step, the electrode was immersed in 1 μM linking probe 2 solution (containing 1 μM linking probe 2, 10 mM Tris-HCl, and 0.1 M NaCl) for 30 min. The obtained CV response, <xref ref-type="fig" rid="f9-sensors-12-07080">Figure S1(c)</xref>, is very similar to S1b, revealing that the electrode surface does not obviously change. However, when the electrode was immersed into linking probe 2 solution containing Hg<sup>2+</sup> for 10 min, hardly any redox peaks of [Fe(CN)<sub>6</sub>]<sup>4−/3−</sup> can be observed, as shown in <xref ref-type="fig" rid="f9-sensors-12-07080">Figure S1(d)</xref>. This likely is attributed to the formation of the sandwich structure of T-Hg<sup>2+</sup>-T, which further block the electron transfer of [Fe(CN)<sub>6</sub>]<sup>4−/3−</sup> at electrode surface. These results also can be demonstrated by EIS, as shown in <xref ref-type="fig" rid="f10-sensors-12-07080">Figure S2</xref>.</p>
<fig id="f9-sensors-12-07080" position="anchor">
<label>Figure S1.</label>
<caption>
<p>Characterization of the sensing interface by CV. (<bold>a</bold>) bare electrode; (<bold>b</bold>) after immobilization of capturing probe; (<bold>c</bold>) incubation with 1 μM linking probe 2 solution without Hg<sup>2+</sup> for 30 min; (<bold>d</bold>) incubation with 1 μM linking probe 2 solution containing 0.5 μM for 10 min.</p></caption>
<graphic xlink:href="sensors-12-07080f9.gif"/></fig>
<fig id="f10-sensors-12-07080" position="anchor">
<label>Figure S2.</label>
<caption>
<p>Characterization of the sensing interface by EIS. The procedure is the same as <xref ref-type="fig" rid="f9-sensors-12-07080">Figure S1</xref>.</p></caption>
<graphic xlink:href="sensors-12-07080f10.gif"/></fig>
<fig id="f11-sensors-12-07080" position="anchor">
<label>Figure S3.</label>
<caption>
<p>Schematic representation of the QCM-based sensor for detection of the Hg<sup>2+</sup> (R<sub>1</sub>: Tris-HCl buffer; R<sub>2</sub>: linking probe 1; R<sub>3</sub>: linking probe 2; R<sub>4</sub>: cysteine).</p></caption>
<graphic xlink:href="sensors-12-07080f11.gif"/></fig></sec></app></app-group>
<ref-list>
<title>References</title>
<ref id="b1-sensors-12-07080"><label>1.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Cotton</surname><given-names>F.A.</given-names></name><name><surname>Wilkinson</surname><given-names>G.</given-names></name><name><surname>Murillo</surname><given-names>C.A.</given-names></name><name><surname>Bochmann</surname><given-names>M.</given-names></name></person-group><source>Advanced Inorganic Chemistry</source><edition>6th ed.</edition><publisher-name>John Wiley &amp; Sons</publisher-name><publisher-loc>New York, NY, USA</publisher-loc><year>1999</year><fpage>2729</fpage></citation></ref>
<ref id="b2-sensors-12-07080"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Clarkson</surname><given-names>T.W.</given-names></name><name><surname>Magos</surname><given-names>L.</given-names></name><name><surname>Myers</surname><given-names>G.J.N.</given-names></name></person-group><article-title>The toxicology of mercury-current exposures and clinical manifestations</article-title><source>N. Engl. J. Med.</source><year>2003</year><volume>349</volume><fpage>1731</fpage><lpage>1737</lpage><pub-id pub-id-type="doi">10.1056/NEJMra022471</pub-id><pub-id pub-id-type="pmid">14585942</pub-id></citation></ref>
<ref id="b3-sensors-12-07080"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dieguez-Acuna</surname><given-names>F.J.</given-names></name><name><surname>Ellis</surname><given-names>M.E.</given-names></name><name><surname>Kushleika</surname><given-names>J.</given-names></name><name><surname>Woods</surname><given-names>J.S.</given-names></name></person-group><article-title>Mercuric ion attenuates NF-kB activation and DNA binding in normal rat kidney epithelial cells: Implications for mercury-induced nephrotoxicity</article-title><source>Toxicol. Appl. Pharmacol.</source><year>2001</year><volume>173</volume><fpage>176</fpage><lpage>187</lpage><pub-id pub-id-type="doi">10.1006/taap.2001.9195</pub-id><pub-id pub-id-type="pmid">11437639</pub-id></citation></ref>
<ref id="b4-sensors-12-07080"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lund</surname><given-names>B.O.</given-names></name><name><surname>Miller</surname><given-names>D.M.</given-names></name><name><surname>Woods</surname><given-names>J.S.</given-names></name></person-group><article-title>Studies on Hg(II)-induced hydrogen peroxide formation and oxidative stress <italic>in vivo</italic> and <italic>in vitro</italic> in rat kidney mitochondria</article-title><source>Biochem. Pharmacol.</source><year>1993</year><volume>45</volume><fpage>2017</fpage><lpage>2024</lpage><pub-id pub-id-type="doi">10.1016/0006-2952(93)90012-L</pub-id><pub-id pub-id-type="pmid">8512585</pub-id></citation></ref>
<ref id="b5-sensors-12-07080"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sekowski</surname><given-names>J.W.</given-names></name><name><surname>Malkas</surname><given-names>L.H.</given-names></name><name><surname>Wei</surname><given-names>Y.</given-names></name><name><surname>Hickey</surname><given-names>R.J.</given-names></name></person-group><article-title>Mercuric ion inhibits the activity and fidelity of the human cell DNA synthesome</article-title><source>Toxicol. Appl. Pharmacol.</source><year>1997</year><volume>145</volume><fpage>268</fpage><lpage>276</lpage><pub-id pub-id-type="doi">10.1006/taap.1997.8185</pub-id><pub-id pub-id-type="pmid">9266799</pub-id></citation></ref>
<ref id="b6-sensors-12-07080"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yoon</surname><given-names>S.</given-names></name><name><surname>Miller</surname><given-names>E.W.</given-names></name><name><surname>He</surname><given-names>Q.</given-names></name><name><surname>Do</surname><given-names>P.H.</given-names></name><name><surname>Chang</surname><given-names>C.J.</given-names></name></person-group><article-title>A bright and specific fluorescent sensor for mercury in water, cells, and tissue</article-title><source>Angew. Chem. Int. Ed.</source><year>2007</year><volume>46</volume><fpage>6658</fpage><lpage>6660</lpage><pub-id pub-id-type="doi">10.1002/anie.200701785</pub-id></citation></ref>
<ref id="b7-sensors-12-07080"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Nolan</surname><given-names>E.M.</given-names></name><name><surname>Lippard</surname><given-names>S.J.</given-names></name></person-group><article-title>Tools and tactics for the optical detection of mercuric ion</article-title><source>Chem. Rev.</source><year>2008</year><volume>108</volume><fpage>3443</fpage><lpage>3480</lpage><pub-id pub-id-type="doi">10.1021/cr068000q</pub-id><pub-id pub-id-type="pmid">18652512</pub-id></citation></ref>
<ref id="b8-sensors-12-07080"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yoon</surname><given-names>S.</given-names></name><name><surname>Albers</surname><given-names>A.E.</given-names></name><name><surname>Wong</surname><given-names>A.P.</given-names></name><name><surname>Chang</surname><given-names>C.J.</given-names></name></person-group><article-title>Screening mercury levels in fish with a selective fluorescent chemosensor</article-title><source>J. Am. Chem. Soc.</source><year>2005</year><volume>127</volume><fpage>16030</fpage><lpage>16031</lpage><pub-id pub-id-type="doi">10.1021/ja0557987</pub-id><pub-id pub-id-type="pmid">16287282</pub-id></citation></ref>
<ref id="b9-sensors-12-07080"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Clever</surname><given-names>G.H.</given-names></name><name><surname>Kaul</surname><given-names>C.</given-names></name><name><surname>Carell</surname><given-names>T.</given-names></name></person-group><article-title>DNA-metal base pairs</article-title><source>Angew. Chem. Int. Ed.</source><year>2007</year><volume>46</volume><fpage>6226</fpage><lpage>6236</lpage><pub-id pub-id-type="doi">10.1002/anie.200701185</pub-id></citation></ref>
<ref id="b10-sensors-12-07080"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Miyake</surname><given-names>Y.</given-names></name><name><surname>Togashi</surname><given-names>H.</given-names></name><name><surname>Tashiro</surname><given-names>M.</given-names></name><name><surname>Yamaguchi</surname><given-names>H.</given-names></name><name><surname>Oda</surname><given-names>S.</given-names></name><name><surname>Kudo</surname><given-names>M.</given-names></name><name><surname>Tanaka</surname><given-names>Y.</given-names></name><name><surname>Kondo</surname><given-names>Y.</given-names></name><name><surname>Sawa</surname><given-names>R.</given-names></name><name><surname>Fujimoto</surname><given-names>T.</given-names></name><etal/></person-group><article-title>MercuryII-mediated formation of thymine-HgII-thymine base pairs in DNA duplexes</article-title><source>J. Am. Chem. Soc.</source><year>2006</year><volume>128</volume><fpage>2172</fpage><lpage>2173</lpage><pub-id pub-id-type="doi">10.1021/ja056354d</pub-id><pub-id pub-id-type="pmid">16478145</pub-id></citation></ref>
<ref id="b11-sensors-12-07080"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sheng</surname><given-names>Z.H.</given-names></name><name><surname>Han</surname><given-names>J.H.</given-names></name><name><surname>Zhang</surname><given-names>J.P.</given-names></name><name><surname>Zhao</surname><given-names>H.</given-names></name><name><surname>Jiang</surname><given-names>L.</given-names></name></person-group><article-title>Method for detection of Hg<sup>2+</sup> based on the specific thymine-Hg<sup>2+</sup>-thymine interaction in the DNA hybridization on the surface of quartz crystal microbalance</article-title><source>Colloids Surf. B: Biointerfaces</source><year>2011</year><volume>87</volume><fpage>289</fpage><lpage>292</lpage><pub-id pub-id-type="doi">10.1016/j.colsurfb.2011.05.031</pub-id></citation></ref>
<ref id="b12-sensors-12-07080"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname><given-names>Z.Q.</given-names></name><name><surname>Su</surname><given-names>Y.Y.</given-names></name><name><surname>Li</surname><given-names>J.</given-names></name><name><surname>Li</surname><given-names>D.</given-names></name><name><surname>Zhang</surname><given-names>J.</given-names></name><name><surname>Song</surname><given-names>S.P.</given-names></name><name><surname>Zhao</surname><given-names>Y.</given-names></name><name><surname>Li</surname><given-names>G.X.</given-names></name><name><surname>Fan</surname><given-names>C.H.</given-names></name></person-group><article-title>Highly sensitive electrochemical sensor for mercury II ions by using a mercury specific oligonucleotide probe and gold nanoparticle based amplification</article-title><source>Anal. Chem.</source><year>2009</year><volume>81</volume><fpage>7660</fpage><lpage>7666</lpage><pub-id pub-id-type="doi">10.1021/ac9010809</pub-id><pub-id pub-id-type="pmid">19691296</pub-id></citation></ref>
<ref id="b13-sensors-12-07080"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lin</surname><given-names>Y.W.</given-names></name><name><surname>Liu</surname><given-names>C.W.</given-names></name><name><surname>Chang</surname><given-names>H.T.</given-names></name></person-group><article-title>Fluorescence detection of mercury(II) and lead(II) ions using aptamer/reporter conjugates</article-title><source>Talanta</source><year>2011</year><volume>84</volume><fpage>324</fpage><lpage>329</lpage><pub-id pub-id-type="doi">10.1016/j.talanta.2011.01.016</pub-id><pub-id pub-id-type="pmid">21376952</pub-id></citation></ref>
<ref id="b14-sensors-12-07080"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname><given-names>Y.</given-names></name><name><surname>Yang</surname><given-names>F.</given-names></name><name><surname>Yang</surname><given-names>X.R.</given-names></name></person-group><article-title>Colorimetric biosensing of mercury(II) ion using unmodified gold nanoparticle probes and thrombin-binding aptamer</article-title><source>Biosens. Bioelectron.</source><year>2010</year><volume>25</volume><fpage>1994</fpage><lpage>1998</lpage><pub-id pub-id-type="doi">10.1016/j.bios.2010.01.014</pub-id><pub-id pub-id-type="pmid">20138750</pub-id></citation></ref>
<ref id="b15-sensors-12-07080"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lai</surname><given-names>Y.Q.</given-names></name><name><surname>Ma</surname><given-names>Y.Y.</given-names></name><name><surname>Sun</surname><given-names>L.P.</given-names></name><name><surname>Jia</surname><given-names>J.</given-names></name><name><surname>Weng</surname><given-names>J.</given-names></name><name><surname>Hu</surname><given-names>N.</given-names></name><name><surname>Yang</surname><given-names>W.</given-names></name><name><surname>Zhang</surname><given-names>Q.Q.</given-names></name></person-group><article-title>A highly selective electrochemical biosensor for Hg<sup>2+</sup> using hemin as a redox indicator</article-title><source>Electrochim. Acta</source><year>2011</year><volume>56</volume><fpage>3153</fpage><lpage>3158</lpage><pub-id pub-id-type="doi">10.1016/j.electacta.2011.01.061</pub-id></citation></ref>
<ref id="b16-sensors-12-07080"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ono</surname><given-names>A.</given-names></name><name><surname>Togashi</surname><given-names>H.</given-names></name></person-group><article-title>Highly selective oligonucleotide-based sensor mercury II aqueous solutions</article-title><source>Angew. Chem. Int. Ed.</source><year>2004</year><volume>43</volume><fpage>4300</fpage><lpage>4302</lpage><pub-id pub-id-type="doi">10.1002/anie.200454172</pub-id></citation></ref>
<ref id="b17-sensors-12-07080"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Xue</surname><given-names>X.J.</given-names></name><name><surname>Wang</surname><given-names>F.</given-names></name><name><surname>Liu</surname><given-names>X.G.</given-names></name></person-group><article-title>One-step, room temperature, colorimetric detection of mercury (Hg<sup>2+</sup>) using DNA/nanoparticle conjugates</article-title><source>J. Am. Chem. Soc.</source><year>2008</year><volume>130</volume><fpage>3244</fpage><lpage>3245</lpage><pub-id pub-id-type="doi">10.1021/ja076716c</pub-id><pub-id pub-id-type="pmid">18293973</pub-id></citation></ref>
<ref id="b18-sensors-12-07080"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname><given-names>D.</given-names></name><name><surname>Wieckowska</surname><given-names>A.</given-names></name><name><surname>Willner</surname><given-names>I.</given-names></name></person-group><article-title>Optical analysis of Hg<sup>2+</sup> ions by oligonucleotide-gold-nanoparticle hybrids and DNA-based machines</article-title><source>Angew. Chem. Int. Ed.</source><year>2008</year><volume>47</volume><fpage>3927</fpage><lpage>3931</lpage><pub-id pub-id-type="doi">10.1002/anie.200705991</pub-id></citation></ref>
<ref id="b19-sensors-12-07080"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname><given-names>H.</given-names></name><name><surname>Harpster</surname><given-names>M.H.</given-names></name><name><surname>Park</surname><given-names>H.J.</given-names></name><name><surname>Johnson</surname><given-names>P.A.</given-names></name></person-group><article-title>Surface-enhanced Raman scattering detection of DNA derived from the West Nile virus genome using magnetic capture of Raman-active gold nanoparticles</article-title><source>Anal. Chem.</source><year>2011</year><volume>83</volume><fpage>254</fpage><lpage>260</lpage><pub-id pub-id-type="doi">10.1021/ac1023843</pub-id><pub-id pub-id-type="pmid">21121693</pub-id></citation></ref>
<ref id="b20-sensors-12-07080"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pelossof</surname><given-names>G.</given-names></name><name><surname>Tel-Vered</surname><given-names>R.</given-names></name><name><surname>Liu</surname><given-names>X.Q.</given-names></name><name><surname>Willner</surname><given-names>I.</given-names></name></person-group><article-title>Amplified surface plasmon resonance based DNA biosensors, aptasensors, and Hg<sup>2+</sup> sensors using hemin/G-quadruplexes and Au nanoparticles</article-title><source>Chem. Eur. J.</source><year>2011</year><volume>17</volume><fpage>8904</fpage><lpage>8912</lpage><pub-id pub-id-type="doi">10.1002/chem.201100601</pub-id><pub-id pub-id-type="pmid">21726008</pub-id></citation></ref>
<ref id="b21-sensors-12-07080"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tang</surname><given-names>Y.L.</given-names></name><name><surname>He</surname><given-names>F.</given-names></name><name><surname>Yu</surname><given-names>M.H.</given-names></name><name><surname>Feng</surname><given-names>F.D.</given-names></name><name><surname>An</surname><given-names>L.L.</given-names></name><name><surname>Sun</surname><given-names>H.</given-names></name><name><surname>Wang</surname><given-names>S.</given-names></name><name><surname>Li</surname><given-names>Y.L.</given-names></name><name><surname>Zhu</surname><given-names>D.B.</given-names></name></person-group><article-title>Reversible highly selective fluorescent sensor mercury II using poly thiophenes contain thymine moieties</article-title><source>Macromol. Rapid Commun.</source><year>2006</year><volume>27</volume><fpage>389</fpage><lpage>392</lpage><pub-id pub-id-type="doi">10.1002/marc.200500837</pub-id></citation></ref>
<ref id="b22-sensors-12-07080"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname><given-names>Z.D.</given-names></name><name><surname>Lee</surname><given-names>J.H.</given-names></name><name><surname>Lu</surname><given-names>Y.</given-names></name></person-group><article-title>Highly sensitive “turn-on” fluorescent sensor for Hg<sup>2+</sup> in aqueous solution based on structure-switching DNA</article-title><source>Chem. Commun.</source><year>2008</year><volume>45</volume><fpage>6005</fpage><lpage>6007</lpage></citation></ref>
<ref id="b23-sensors-12-07080"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname><given-names>X.</given-names></name><name><surname>Zhou</surname><given-names>X.M.</given-names></name><name><surname>Xing</surname><given-names>D.</given-names></name></person-group><article-title>Ultrasensitive and selective detection of mercury(II) in aqueous solution by polymerase assisted fluorescence amplification</article-title><source>Biosens. Bioelectron.</source><year>2011</year><volume>26</volume><fpage>2666</fpage><lpage>2669</lpage><pub-id pub-id-type="doi">10.1016/j.bios.2010.03.013</pub-id><pub-id pub-id-type="pmid">20363610</pub-id></citation></ref>
<ref id="b24-sensors-12-07080"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mor-Piperberg</surname><given-names>G.</given-names></name><name><surname>Tel-Vered</surname><given-names>R.</given-names></name><name><surname>Elbaz</surname><given-names>J.</given-names></name><name><surname>Willner</surname><given-names>I.</given-names></name></person-group><article-title>Nanoengineered electrically contacted enzymes on DNA scaffolds functional assemblies for the selective analysis of Hg<sup>2+</sup> ions</article-title><source>J. Am. Chem. Soc.</source><year>2010</year><volume>132</volume><fpage>6878</fpage><lpage>6879</lpage><pub-id pub-id-type="doi">10.1021/ja1006355</pub-id><pub-id pub-id-type="pmid">20426465</pub-id></citation></ref>
<ref id="b25-sensors-12-07080"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tuleuova</surname><given-names>N.</given-names></name><name><surname>Jones</surname><given-names>C.N.</given-names></name><name><surname>Yan</surname><given-names>J.</given-names></name><name><surname>Ramanculov</surname><given-names>E.</given-names></name><name><surname>Yokobayashi</surname><given-names>Y.</given-names></name><name><surname>Revzin</surname><given-names>A.</given-names></name></person-group><article-title>Development of an aptamer beacon for detection of interferon-gamma</article-title><source>Anal. Chem.</source><year>2010</year><volume>82</volume><fpage>1851</fpage><lpage>1857</lpage><pub-id pub-id-type="doi">10.1021/ac9025237</pub-id><pub-id pub-id-type="pmid">20121141</pub-id></citation></ref>
<ref id="b26-sensors-12-07080"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Baker</surname><given-names>B.R.</given-names></name><name><surname>Lai</surname><given-names>R.Y.</given-names></name><name><surname>Wood</surname><given-names>M.S.</given-names></name><name><surname>Doctor</surname><given-names>E.H.</given-names></name><name><surname>Heeger</surname><given-names>A.J.</given-names></name><name><surname>Plaxco</surname><given-names>K.W.</given-names></name></person-group><article-title>An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological fluids</article-title><source>J. Am. Chem. Soc.</source><year>2006</year><volume>128</volume><fpage>3138</fpage><lpage>3139</lpage><pub-id pub-id-type="doi">10.1021/ja056957p</pub-id><pub-id pub-id-type="pmid">16522082</pub-id></citation></ref>
<ref id="b27-sensors-12-07080"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Xiao</surname><given-names>Y.</given-names></name><name><surname>Piorek</surname><given-names>B.D.</given-names></name><name><surname>Plaxco</surname><given-names>K.W.</given-names></name><name><surname>Heeger</surname><given-names>A.J.</given-names></name></person-group><article-title>A re-agentless signal-on architecture for electronic, aptamer-based sensors via target-induced strand displacement</article-title><source>J. Am. Chem. Soc.</source><year>2005</year><volume>127</volume><fpage>17990</fpage><lpage>17991</lpage><pub-id pub-id-type="doi">10.1021/ja056555h</pub-id><pub-id pub-id-type="pmid">16366535</pub-id></citation></ref>
<ref id="b28-sensors-12-07080"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sauerbrey</surname><given-names>G.Z.</given-names></name></person-group><article-title>The use of quartz oscillators for weighing thin layers and for microweighing</article-title><source>Zeitschrift Für Physik</source><year>1959</year><volume>155</volume><fpage>206</fpage><lpage>222</lpage><pub-id pub-id-type="doi">10.1007/BF01337937</pub-id></citation></ref>
<ref id="b29-sensors-12-07080"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname><given-names>J.S.</given-names></name><name><surname>Ulmann</surname><given-names>A.P.</given-names></name><name><surname>Han</surname><given-names>S.M.</given-names></name><name><surname>Mirkan</surname><given-names>A.C.</given-names></name></person-group><article-title>A DNA-gold nanoparticle-based colorimetric competition assay for the detection of cysteine</article-title><source>Nano. Lett.</source><year>2008</year><volume>8</volume><fpage>529</fpage><lpage>533</lpage><pub-id pub-id-type="doi">10.1021/nl0727563</pub-id><pub-id pub-id-type="pmid">18205426</pub-id></citation></ref>
<ref id="b30-sensors-12-07080"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sota</surname><given-names>H.</given-names></name><name><surname>Yoshimine</surname><given-names>H.</given-names></name><name><surname>Whittier</surname><given-names>R.F.</given-names></name><name><surname>Gotoh</surname><given-names>M.</given-names></name><name><surname>Shinohara</surname><given-names>Y.</given-names></name><name><surname>Hasegawa</surname><given-names>Y.</given-names></name><name><surname>Okahata</surname><given-names>Y.</given-names></name></person-group><article-title>A versatile planar QCM-based sensor design for nonlabeling biomolecule detection</article-title><source>Anal. Chem.</source><year>2002</year><volume>74</volume><fpage>3592</fpage><lpage>3598</lpage><pub-id pub-id-type="doi">10.1021/ac025526b</pub-id><pub-id pub-id-type="pmid">12175141</pub-id></citation></ref>
<ref id="b31-sensors-12-07080"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Steel</surname><given-names>A.B.</given-names></name><name><surname>Herne</surname><given-names>T.M.</given-names></name><name><surname>Tarlov</surname><given-names>M.J.</given-names></name></person-group><article-title>Electrochemical quantization of DNA immobilized on gold</article-title><source>Anal. Chem.</source><year>1998</year><volume>70</volume><fpage>4670</fpage><lpage>4677</lpage><pub-id pub-id-type="doi">10.1021/ac980037q</pub-id><pub-id pub-id-type="pmid">9844566</pub-id></citation></ref>
<ref id="b32-sensors-12-07080"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Grabar</surname><given-names>K.C.</given-names></name><name><surname>Smith</surname><given-names>P.C.</given-names></name><name><surname>Musick</surname><given-names>M.D.</given-names></name><name><surname>Davis</surname><given-names>J.A.</given-names></name><name><surname>Walter</surname><given-names>D.G.</given-names></name><name><surname>Jackson</surname><given-names>M.A.</given-names></name><name><surname>Guthrie</surname><given-names>A.P.</given-names></name><name><surname>Natan</surname><given-names>M.J.</given-names></name></person-group><article-title>Kinetic control of interparticle spacing in Au colloid-based surface: Rational nanometer-scale architecture</article-title><source>J. Am. Chem. Soc.</source><year>1996</year><volume>118</volume><fpage>1148</fpage><lpage>1153</lpage><pub-id pub-id-type="doi">10.1021/ja952233+</pub-id></citation></ref>
<ref id="b33-sensors-12-07080"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname><given-names>J.Q.</given-names></name><name><surname>Wang</surname><given-names>Y.S.</given-names></name><name><surname>He</surname><given-names>Y.</given-names></name><name><surname>Jiang</surname><given-names>T.</given-names></name><name><surname>Yang</surname><given-names>H.M.</given-names></name><name><surname>Tan</surname><given-names>X.</given-names></name><name><surname>Kang</surname><given-names>R.H.</given-names></name><name><surname>Yuan</surname><given-names>Y.K.</given-names></name><name><surname>Shi</surname><given-names>L.F.</given-names></name></person-group><article-title>Determination of urinary adenosine using resonance light scattering of gold nanoparticles modified structure-switching aptamer</article-title><source>Anal. Biochem.</source><year>2010</year><volume>397</volume><fpage>212</fpage><lpage>217</lpage><pub-id pub-id-type="doi">10.1016/j.ab.2009.10.027</pub-id><pub-id pub-id-type="pmid">19849997</pub-id></citation></ref>
<ref id="b34-sensors-12-07080"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jin</surname><given-names>R.C.</given-names></name><name><surname>Wu</surname><given-names>G.S.</given-names></name><name><surname>Li</surname><given-names>Z.</given-names></name><name><surname>Mirkin</surname><given-names>C.A.</given-names></name><name><surname>Schatz</surname><given-names>G.C.</given-names></name></person-group><article-title>What controls the melting properties of DNA-linked gold nanoparticle assemblies?</article-title><source>J. Am. Chem. Soc.</source><year>2003</year><volume>125</volume><fpage>1643</fpage><lpage>1654</lpage><pub-id pub-id-type="doi">10.1021/ja021096v</pub-id><pub-id pub-id-type="pmid">12568626</pub-id></citation></ref>
<ref id="b35-sensors-12-07080"><label>35.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname><given-names>S.H.</given-names></name><name><surname>Chuang</surname><given-names>Y.C.</given-names></name><name><surname>Lu</surname><given-names>Y.C.</given-names></name><name><surname>Lin</surname><given-names>H.C.</given-names></name><name><surname>Yang</surname><given-names>Y.L.</given-names></name><name><surname>Lin</surname><given-names>C.S.</given-names></name></person-group><article-title>A method of layer-by-layer gold nanoparticle hybridization in a quartz crystal microbalance DNA sensing system used to detect dengue virus</article-title><source>Nanotechnology</source><year>2009</year><volume>20</volume><fpage>215501</fpage><pub-id pub-id-type="doi">10.1088/0957-4484/20/21/215501</pub-id><pub-id pub-id-type="pmid">19423930</pub-id></citation></ref>
<ref id="b36-sensors-12-07080"><label>36.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kira</surname><given-names>A.</given-names></name><name><surname>Kim</surname><given-names>H.</given-names></name><name><surname>Yasuda</surname><given-names>K.</given-names></name></person-group><article-title>Contribution of nanoscale nurvature to number density of immobilized DNA on gold nanoparticles</article-title><source>Langmuir</source><year>2009</year><volume>25</volume><fpage>1285</fpage><lpage>1288</lpage><pub-id pub-id-type="doi">10.1021/la803385x</pub-id><pub-id pub-id-type="pmid">19132834</pub-id></citation></ref>
<ref id="b37-sensors-12-07080"><label>37.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>White</surname><given-names>R.J.</given-names></name><name><surname>Phares</surname><given-names>N.</given-names></name><name><surname>Lubin</surname><given-names>A.A.</given-names></name><name><surname>Xiao</surname><given-names>Y.</given-names></name><name><surname>Plaxco</surname><given-names>K.W.</given-names></name></person-group><article-title>Optimization of electrochemical aptamer-based sensors via optimization of probe packing density and surface chemistry</article-title><source>Langmuir</source><year>2008</year><volume>24</volume><fpage>10513</fpage><lpage>10518</lpage><pub-id pub-id-type="doi">10.1021/la800801v</pub-id><pub-id pub-id-type="pmid">18690727</pub-id></citation></ref>
<ref id="b38-sensors-12-07080"><label>38.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname><given-names>Y.</given-names></name><name><surname>Nazgul</surname><given-names>T.</given-names></name><name><surname>Erlan</surname><given-names>R.</given-names></name><name><surname>Alexander</surname><given-names>R.</given-names></name></person-group><article-title>Aptamer-based electrochemical biosensor for interferon gamma detection</article-title><source>Anal. Chem.</source><year>2010</year><volume>82</volume><fpage>8131</fpage><lpage>8136</lpage><pub-id pub-id-type="doi">10.1021/ac101409t</pub-id><pub-id pub-id-type="pmid">20815336</pub-id></citation></ref>
<ref id="b39-sensors-12-07080"><label>39.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname><given-names>J.</given-names></name><name><surname>Lu</surname><given-names>Y.</given-names></name></person-group><article-title>Rational design of “turn-on” allosteric DNAzyme catalytic beacons for aqueous mercury ions</article-title><source>Angew. Chem. Int. Ed.</source><year>2007</year><volume>46</volume><fpage>7587</fpage><lpage>7590</lpage><pub-id pub-id-type="doi">10.1002/anie.200702006</pub-id></citation></ref>
<ref id="b40-sensors-12-07080"><label>40.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname><given-names>J.S.</given-names></name><name><surname>Han</surname><given-names>M.S.</given-names></name><name><surname>Mirkin</surname><given-names>C.A.</given-names></name></person-group><article-title>Colorimetric detection of mercuric ion (Hg<sup>2+</sup>) in aqueous media using DNA-functionalized gold nanoparticles</article-title><source>Angew. Chem. Int. Ed.</source><year>2007</year><volume>46</volume><fpage>4093</fpage><lpage>4096</lpage><pub-id pub-id-type="doi">10.1002/anie.200700269</pub-id></citation></ref>
<ref id="b41-sensors-12-07080"><label>41.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname><given-names>T.</given-names></name><name><surname>Dong</surname><given-names>S.J.</given-names></name><name><surname>Wang</surname><given-names>E.</given-names></name></person-group><article-title>Label-free colorimetric detection of aqueous mercury ion (Hg<sup>2+</sup>) using Hg<sup>2+</sup>-modulated G-quadruplex-based DNAzymes</article-title><source>Anal. Chem.</source><year>2009</year><volume>81</volume><fpage>2144</fpage><lpage>2149</lpage><pub-id pub-id-type="doi">10.1021/ac900188y</pub-id><pub-id pub-id-type="pmid">19227981</pub-id></citation></ref></ref-list>
<sec sec-type="display-objects">
<title>Figures and Tables</title>
<fig id="f1-sensors-12-07080" position="float">
<label>Figure 1.</label>
<caption>
<p>SEM images of (<bold>A</bold>) the bare Au electrode surface; (<bold>B</bold>) the Au electrode surface after hybridizing capturing probe with linking probe 1 in 0.5 μM Hg<sup>2+</sup> solution and (<bold>C</bold>) the Au electrode surface after hybridizing capturing probe with linking probe 2 in 0.5 μM Hg<sup>2+</sup> solution.</p></caption>
<graphic xlink:href="sensors-12-07080f1.gif"/></fig>
<fig id="f2-sensors-12-07080" position="float">
<label>Figure 2.</label>
<caption>
<p>The response of QCM-based sensor to Hg<sup>2+</sup>. (a,b) section: 1 μM linking probe 2 solution was injected at a flow rate of 20 μL·min<sup>−1</sup> for 600 s; (b,c) section: 5 nM Hg<sup>2+</sup> solution was injected into the QCM cell; (c,d) section: 10 mM Tris-HCl buffer (pH 7.4) containing 50 mM cysteine was injected at a flow rate of 25 μL·min<sup>−1</sup> for 900 s.</p></caption>
<graphic xlink:href="sensors-12-07080f2.gif"/></fig>
<fig id="f3-sensors-12-07080" position="float">
<label>Figure 3.</label>
<caption>
<p>Signal responses of the QCM-based sensor to Hg<sup>2+</sup> in different linking probe solution. (<bold>A</bold>) Tris-HCl buffer without linking probe; (<bold>B</bold>) linking probe 1; (<bold>C</bold>) linking probe 2.</p></caption>
<graphic xlink:href="sensors-12-07080f3.gif"/></fig>
<fig id="f4-sensors-12-07080" position="float">
<label>Figure 4.</label>
<caption>
<p>The dependence of the sensor signals on the surface density in the presence of 50 nM Hg<sup>2+</sup> solution.</p></caption>
<graphic xlink:href="sensors-12-07080f4.gif"/></fig>
<fig id="f5-sensors-12-07080" position="float">
<label>Figure 5.</label>
<caption>
<p>The dependence of the response signal of QCM-based sensor on Hg<sup>2+</sup> concentration. Inset: the linear relationship between the Δf and the Hg<sup>2+</sup> concentrations.</p></caption>
<graphic xlink:href="sensors-12-07080f5.gif"/></fig>
<fig id="f6-sensors-12-07080" position="float">
<label>Figure 6.</label>
<caption>
<p>Response of the QCM-based sensor to different ions: (<bold>a</bold>) 0.5 mM Ca<sup>2+</sup>; (<bold>b</bold>) 0.5 mM Mg<sup>2+</sup>; (<bold>c</bold>–<bold>h</bold>) Cu<sup>2+</sup>, Cd<sup>2+</sup>, Pb<sup>2+</sup>, Zn<sup>2+</sup>, Ni<sup>2+</sup>, Ag<sup>+</sup>(0.5 μM, each); (<bold>i</bold>) Au<sup>3+</sup> (0.1 μM) (<bold>j</bold>) 5 nM Hg<sup>2+</sup>; (<bold>k</bold>) the mixture of Ca<sup>2+</sup>, Mg<sup>2+</sup> (0.5 mM, each), Cu<sup>2+</sup>, Cd<sup>2+</sup>, Pb<sup>2+</sup>, Zn<sup>2+</sup>, Ni<sup>2+</sup>, Ag<sup>+</sup>(0.5 μM, each); and 5 nM Hg<sup>2+</sup>.</p></caption>
<graphic xlink:href="sensors-12-07080f6.gif"/></fig>
<fig id="f7-sensors-12-07080" position="float">
<label>Figure 7.</label>
<caption>
<p>Reusability of the QCM-based Hg<sup>2+</sup> sensor challenged with 5 nM Hg<sup>2+</sup> and washed with 50 mM cysteine.</p></caption>
<graphic xlink:href="sensors-12-07080f7.gif"/></fig>
<fig id="f8-sensors-12-07080" position="float">
<label>Scheme 1.</label>
<caption>
<p>Schematic procedure of the sensing interface for detection of Hg<sup>2+</sup> based on (<bold>a</bold>) aptamer and (<bold>b</bold>) aptamer-(Au-NPs) conjugates.</p></caption>
<graphic xlink:href="sensors-12-07080f8.gif"/></fig>
<table-wrap id="t1-sensors-12-07080" position="float">
<label>Table 1.</label>
<caption>
<p>Comparison of the sensitivity of different Hg<sup>2+</sup> sensors.</p></caption>
<table frame="hsides" rules="rows">
<thead>
<tr>
<th align="left" valign="middle"><bold>Aptamer-based Hg<sup>2+</sup> sensor</bold></th>
<th align="center" valign="top"><bold>Limit of detection (nM)</bold></th>
<th align="center" valign="middle"><bold>Reference</bold></th></tr></thead>
<tbody>
<tr>
<td align="left" valign="top">fluorometric assay based on the allosteric DNAzyme catalytic beacons</td>
<td align="center" valign="top">2.4</td>
<td align="center" valign="top">[<xref ref-type="bibr" rid="b39-sensors-12-07080">39</xref>]</td></tr>
<tr>
<td align="left" valign="top">fluorometric assay based on aptamer/reporter conjugates</td>
<td align="center" valign="top">10</td>
<td align="center" valign="top">[<xref ref-type="bibr" rid="b13-sensors-12-07080">13</xref>]</td></tr>
<tr>
<td align="left" valign="top">fluorometric assay based on the aptamer beacon</td>
<td align="center" valign="top">40</td>
<td align="center" valign="top">[<xref ref-type="bibr" rid="b16-sensors-12-07080">16</xref>]</td></tr>
<tr>
<td align="left" valign="top">fluorometric assay based on AuNPs quenched fluorophore modified aptamer</td>
<td align="center" valign="middle">40</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="b14-sensors-12-07080">14</xref>]</td></tr>
<tr>
<td align="left" valign="top">colorimetric assay based on the aggregation of thiolated aptamer modified Au NPs</td>
<td align="center" valign="middle">100</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="b40-sensors-12-07080">40</xref>]</td></tr>
<tr>
<td align="left" valign="top">colorimetric assay based on AuNPs probes and thrombin-binding aptamer</td>
<td align="center" valign="middle">200</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="b14-sensors-12-07080">14</xref>]</td></tr>
<tr>
<td align="left" valign="top">colorimetric assay based on the salt-induced aggregation of nonmodified aptamer stabilized AuNPs</td>
<td align="center" valign="middle">10</td>
<td align="center" valign="middle">[<xref ref-type="bibr" rid="b41-sensors-12-07080">41</xref>]</td></tr>
<tr>
<td align="left" valign="top">square wave voltammetry on AuNPs amplified aptamer based sensor</td>
<td align="center" valign="top">0.5</td>
<td align="center" valign="top">[<xref ref-type="bibr" rid="b12-sensors-12-07080">12</xref>]</td></tr>
<tr>
<td align="left" valign="top">QCM aptamersensor based on signal amplification with gold nanoparticles</td>
<td align="center" valign="middle">0.24</td>
<td align="center" valign="top">Present study</td></tr></tbody></table></table-wrap>
<table-wrap id="t2-sensors-12-07080" position="float">
<label>Table 2.</label>
<caption>
<p>Results obtained in analysis of waste and tap water samples with the QCM-based sensor.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th colspan="10" align="left" valign="top"><bold>Concentration (μg·L<sup>−1</sup>)</bold></th></tr>
<tr>
<th colspan="10" valign="bottom">
<hr/></th></tr>
<tr>
<th align="left" valign="bottom"><bold>Sample</bold></th>
<th align="center" valign="bottom"><bold>Added</bold></th>
<th colspan="5" align="center" valign="bottom"><bold>Found</bold></th>
<th align="center" valign="bottom"><bold>Avg. found</bold></th>
<th align="center" valign="bottom"><bold>RSD, %</bold></th>
<th align="center" valign="bottom"><bold>Recovery, %</bold></th></tr></thead>
<tbody>
<tr>
<td align="left" valign="top" rowspan="3">Waste water</td>
<td align="center" valign="top">0</td>
<td align="center" valign="top">5.8</td>
<td align="center" valign="top">6.2</td>
<td align="center" valign="top">6.3</td>
<td align="center" valign="top">6.4</td>
<td align="center" valign="top">5.9</td>
<td align="center" valign="top">6.10</td>
<td align="center" valign="top">4.2</td>
<td align="center" valign="top">-</td></tr>
<tr>
<td align="center" valign="top">5</td>
<td align="center" valign="top">10.7</td>
<td align="center" valign="top">11.4</td>
<td align="center" valign="top">11.6</td>
<td align="center" valign="top">10.6</td>
<td align="center" valign="top">11.1</td>
<td align="center" valign="top">10.08</td>
<td align="center" valign="top">3.8</td>
<td align="center" valign="top">101.6</td></tr>
<tr>
<td align="center" valign="top">10</td>
<td align="center" valign="top">15.1</td>
<td align="center" valign="top">16.2</td>
<td align="center" valign="top">15.3</td>
<td align="center" valign="top">16.6</td>
<td align="center" valign="top">16.2</td>
<td align="center" valign="top">15.78</td>
<td align="center" valign="top">3.3</td>
<td align="center" valign="top">96.8</td></tr>
<tr>
<td align="left" valign="top" rowspan="3">Tap water</td>
<td align="center" valign="top">0</td>
<td colspan="5" align="center" valign="top">Not found</td>
<td align="center" valign="top">-</td>
<td align="center" valign="top">-</td>
<td align="center" valign="top">-</td></tr>
<tr>
<td align="center" valign="top">10</td>
<td align="center" valign="top">9.6</td>
<td align="center" valign="top">10.4</td>
<td align="center" valign="top">9.7</td>
<td align="center" valign="top">9.9</td>
<td align="center" valign="top">10.1</td>
<td align="center" valign="top">9.94</td>
<td align="center" valign="top">3.2</td>
<td align="center" valign="top">99.4</td></tr>
<tr>
<td align="center" valign="top">20</td>
<td align="center" valign="top">21.0</td>
<td align="center" valign="top">20.1</td>
<td align="center" valign="top">19.8</td>
<td align="center" valign="top">19.6</td>
<td align="center" valign="top">19.8</td>
<td align="center" valign="top">20.06</td>
<td align="center" valign="top">2.7</td>
<td align="center" valign="top">100.3</td></tr></tbody></table></table-wrap></sec></back></article>