<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="en" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Sensors</journal-id>
<journal-title>Sensors</journal-title>
<issn pub-type="epub">1424-8220</issn>
<publisher>
<publisher-name>Molecular Diversity Preservation International (MDPI)</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3390/s120303627</article-id>
<article-id pub-id-type="publisher-id">sensors-12-03627</article-id>
<article-categories>
<subj-group>
<subject>Article</subject></subj-group></article-categories>
<title-group>
<article-title>Scattering Removal for Finger-Vein Image Restoration</article-title></title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Yang</surname><given-names>Jinfeng</given-names></name><xref ref-type="corresp" rid="c1-sensors-12-03627"><sup>★</sup></xref></contrib>
<contrib contrib-type="author">
<name><surname>Zhang</surname><given-names>Ben</given-names></name></contrib>
<contrib contrib-type="author">
<name><surname>Shi</surname><given-names>Yihua</given-names></name></contrib>
<aff id="af1-sensors-12-03627">Tianjin Key Lab for Advanced Signal Processing, Civil Aviation University of China, P.O. Box 9, Tianjin 300300, China; E-Mails: <email>comm.benzhang@gmail.com</email> (B.Z.); <email>yh-shi@cauc.edu.cn</email> (Y.S.)</aff></contrib-group>
<author-notes>
<corresp id="c1-sensors-12-03627">
<label>★</label> Author to whom correspondence should be addressed; E-Mail: <email>jfyang@cauc.edu.cn</email>.</corresp></author-notes>
<pub-date pub-type="collection">
<month>3</month>
<year>2012</year></pub-date>
<pub-date pub-type="epub">
<day>15</day>
<month>3</month>
<year>2012</year></pub-date>
<volume>12</volume>
<issue>3</issue>
<fpage>3627</fpage>
<lpage>3640</lpage>
<history>
<date date-type="received">
<day>7</day>
<month>2</month>
<year>2012</year></date>
<date date-type="rev-recd">
<day>6</day>
<month>3</month>
<year>2012</year></date>
<date date-type="accepted">
<day>6</day>
<month>3</month>
<year>2012</year></date></history>
<permissions>
<copyright-statement>© 2012 by the authors; licensee MDPI, Basel, Switzerland</copyright-statement>
<copyright-year>2012</copyright-year>
<license>
<p>This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).</p></license></permissions>
<abstract>
<p>Finger-vein recognition has received increased attention recently. However, the finger-vein images are always captured in poor quality. This certainly makes finger-vein feature representation unreliable, and further impairs the accuracy of finger-vein recognition. In this paper, we first give an analysis of the intrinsic factors causing finger-vein image degradation, and then propose a simple but effective image restoration method based on scattering removal. To give a proper description of finger-vein image degradation, a biological optical model (BOM) specific to finger-vein imaging is proposed according to the principle of light propagation in biological tissues. Based on BOM, the light scattering component is sensibly estimated and properly removed for finger-vein image restoration. Finally, experimental results demonstrate that the proposed method is powerful in enhancing the finger-vein image contrast and in improving the finger-vein image matching accuracy.</p></abstract>
<kwd-group>
<kwd>image restoration</kwd>
<kwd>finger-vein</kwd>
<kwd>scattering removal</kwd>
<kwd>optical model</kwd></kwd-group></article-meta></front>
<body>
<sec sec-type="intro">
<label>1.</label>
<title>Introduction</title>
<p>Finger-vein recognition, as a highly secure and convenient technique of personal identification, has been attracted much attention for years. In contrast to conventional appearance-based biometric traits such as face, fingerprint and palmprint, finger-vein patterns are hidden beneath the human skin and unnoticeable without the help of some specific viewing or imaging devices. This makes finger-vein trait resistant to steal or forgery, and thereby highly reliable for identity authentication. However, in practical scenario, the inherent advantage of finger-vein can not always be made effectively for finger-vein recognition due to the low contrast of finger-vein images. Therefore, to exploit the genuine characteristics in finger-vein images, the visibility of finger-vein patterns should be improved reliably.</p>
<p>Generally, in order to visualize finger-vein vessels inside the finger tissues, the near infrared (NIR) transillumination is often adopted in imaging devices, as shown in <xref ref-type="fig" rid="f1-sensors-12-03627">Figure 1(a,b)</xref>. As the hemoglobin in blood vessels absorbs more NIR radiation than other substances in finger tissues [<xref ref-type="bibr" rid="b1-sensors-12-03627">1</xref>], the intensity distribution of transmitted NIR rays vary spatially. Vein vessels cast darker “shadows” on imaging plane while other tissues present a brighter background, as shown in <xref ref-type="fig" rid="f1-sensors-12-03627">Figure 1(c)</xref>. Since the biological tissues can be viewed as a kind of highly heterogeneous optical medium, multiple light scattering predominates in lights that penetrate through a biological tissue layer [<xref ref-type="bibr" rid="b2-sensors-12-03627">2</xref>]. Thus, the quality of finger-vein images is always poor because the scattering effects can greatly reduce the contrast between the venous and non-venous regions [<xref ref-type="bibr" rid="b3-sensors-12-03627">3</xref>]. The basic concept of image degradation due to light scattering is illustrated in <xref ref-type="fig" rid="f2-sensors-12-03627">Figure 2</xref>. If no light scattering is generated in optical medium, a real shadow of an object must appear on the imaging plane, as shown in <xref ref-type="fig" rid="f2-sensors-12-03627">Figure 2(a)</xref>. However, the object shadow always is blurred to a certain extent since light scattering is inevitable in real situations, as shown in <xref ref-type="fig" rid="f2-sensors-12-03627">Figure 2(b)</xref>.</p>
<p>Traditionally, for reliable vein-based recognition, many image enhancement methods have been proposed to improve the quality of vein images. Histogram equalization based algorithms were used to enhance the contrast between the venous and background regions in [<xref ref-type="bibr" rid="b5-sensors-12-03627">5</xref>,<xref ref-type="bibr" rid="b6-sensors-12-03627">6</xref>]. Considering the variations of vein-coursing directions, Yang <italic>et al</italic>. [<xref ref-type="bibr" rid="b7-sensors-12-03627">7</xref>–<xref ref-type="bibr" rid="b10-sensors-12-03627">10</xref>] used different oriented filtering strategies to highlight the finger-vein texture. Wang <italic>et al</italic>. [<xref ref-type="bibr" rid="b11-sensors-12-03627">11</xref>] combined the fuzzy and the retinex theory to enhance the near-infrared vein images. Pi <italic>et al</italic>. [<xref ref-type="bibr" rid="b12-sensors-12-03627">12</xref>] used edge-preserving filter and elliptic high-pass filter together to denoise and enhance some small blurred finger veins. Gao <italic>et al</italic>. [<xref ref-type="bibr" rid="b13-sensors-12-03627">13</xref>] combined the traditional high frequency emphasis filtering algorithm and the histogram equalization to sharpen the image contrast. Oh <italic>et al.</italic> [<xref ref-type="bibr" rid="b14-sensors-12-03627">14</xref>] proposed a homomorphic filter incorporating morphological subband decomposition to enhance the dark blood vessels. Although these methods can respectively enhance vein images to some extent, their performances were considerably undesirable in practice since they all did not treat of the key issue of light scattering in degrading finger-vein images.</p>
<p>Strong scattering occurring in the biological tissue during vein imaging is the main reason causing contrast deterioration in finger-vein images [<xref ref-type="bibr" rid="b15-sensors-12-03627">15</xref>]. Therefore, for reliable finger-vein image contrast improvement, this paper aims to find a proper way of scattering removal according to tissue optics, especially skin optics.</p>
<p>In computer vision, scattering removal has been a hot topic for reducing the atmospheric scattering effects on the images of outdoor scenes [<xref ref-type="bibr" rid="b16-sensors-12-03627">16</xref>–<xref ref-type="bibr" rid="b20-sensors-12-03627">20</xref>]. This technique often is termed as dehazing or de-weather, which is based on a physical model that describes the formation of hazing image. Inspired by image dehazing, we here propose an optical-model-based scattering removal algorithm for finger-vein image enhancement. The proposed optical model allows for the light propagation in finger-skin layer such that it is powerful in describing the effects of skin scattering on finger-vein images.</p>
<p>In the following sections, a brief description of image dehazing model is firstly presented, and then the optical model used in this paper is derived after discussing the difference and relationship between our model and image dehazing model. In Section 3, the steps of scattering removal algorithm are detailed. For finger-vein image matching, Phase-Only-Correlation measure is used in Section 4. The experimental results are reported in Section 5. Finally, in Section 6, we give some conclusions.</p></sec>
<sec>
<label>2.</label>
<title>The Optical Model</title>
<p>The physical model widely used to image dehazing, also named Koschmieder model, is expressed as [<xref ref-type="bibr" rid="b21-sensors-12-03627">21</xref>]
<disp-formula id="FD1">
<label>(1)</label>
<mml:math display="block">
<mml:mrow>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mi>d</mml:mi></mml:msub>
<mml:mo>=</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mi>e</mml:mi></mml:mrow>
<mml:mrow>
<mml:mo>−</mml:mo>
<mml:mi mathvariant="italic">Kd</mml:mi></mml:mrow></mml:msup>
<mml:msub>
<mml:mrow>
<mml:mi>I</mml:mi></mml:mrow>
<mml:mn>0</mml:mn></mml:msub>
<mml:mo>+</mml:mo>
<mml:mo stretchy="false">(</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>−</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mi>e</mml:mi></mml:mrow>
<mml:mrow>
<mml:mo>−</mml:mo>
<mml:mi mathvariant="italic">Kd</mml:mi></mml:mrow></mml:msup>
<mml:mo stretchy="false">)</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>I</mml:mi></mml:mrow>
<mml:mo>∞</mml:mo></mml:msub>
<mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>This model provides a very simple and elegant description for two main effects of atmospheric scattering on the observed intensity <italic>I<sub>d</sub></italic> of an object at a distance <italic>d</italic> in a hazing or foggy day. Here, the intensity at close range (distance <italic>d</italic> = 0) <italic>I</italic><sub>0</sub> is called the intrinsic intensity of the object, <italic>I<sub>∞</sub></italic> is the intensity of environmental illumination (equivalent to an object at infinite distance), which is generally assumed to be globally constant, and <italic>K</italic> is the extinction coefficient of the atmosphere.</p>
<p>As illustrated in <xref ref-type="fig" rid="f3-sensors-12-03627">Figure 3</xref>, the first effect of atmospheric scattering is called direct attenuation, and can be described by Beer–Lambert law, which results in an exponential attenuation of object intensity with the transmission distance through scattering media, i.e., the first term <italic>e</italic><sup>−<italic>Kd</italic></sup><italic>I</italic><sub>0</sub> on the right side of <xref ref-type="disp-formula" rid="FD1">Equation (1)</xref>. The second effect, referred to as airlight in Koschmieder theory of horizontal visibility, is caused by the suspended particles in haze or fog that scatter the environmental illumination toward the observer. The airlight acts as an additional radiation superimposed on the image of the object, whose intensity is related to the environmental illumination <italic>I<sub>∞</sub></italic> and increases with pathlength <italic>d</italic> from the observer to the object, as described by the term (1 − <italic>e</italic><sup>−</sup><italic><sup>Kd</sup></italic>)<italic>I<sub>∞</sub></italic>.</p>
<p>It is noticeable that, despite having not taken multiple scattering into account, the Koschmieder model is practicable for vision applications. In atmosphere, the distances between particles are usually large enough so that the particles can be viewed as independent scatterers, whose scattered intensities do not significantly interfere with each other, and thus the effect of multiple scattering is negligible [<xref ref-type="bibr" rid="b22-sensors-12-03627">22</xref>]. Whereas, in the case of biological tissue, light propagation suffers a more complex process due to the complexity of tissue structure. Particularly, the scattering particles in biological tissue are so dense that the interaction of scattered intensities between neighboring particles cannot be ignored [<xref ref-type="bibr" rid="b23-sensors-12-03627">23</xref>]. Hence, multiple scattering is said to be prevalent in the biological optical medium.</p>
<p>From the biophotonic point of view, as the light propagates through a tissue, the transmitted light is composed of three components—the ballistic, the snake, and the diffuse photons [<xref ref-type="bibr" rid="b24-sensors-12-03627">24</xref>], as shown in <xref ref-type="fig" rid="f4-sensors-12-03627">Figure 4</xref>. Ballistic photons travel a straight, undeviated path in the medium. Snake photons experience some slight scattering events, but still propagate in the forward or near-forward direction. Diffuse photons undergo multiple scattering and emerge from random directions. Obviously, in transillumination imaging of objects embedded in the biological tissue, the ballistic photons with propagation direction preservation can form sharp shadows of objects on the imaging plane, whereas the multiple scattered diffuse photons can inevitably reduce the contrast of the shadows as well as giving rise to the unwanted, incoherent imaging background [<xref ref-type="bibr" rid="b25-sensors-12-03627">25</xref>]. That is to say, the multiple scattering is the most unfavorable factor that contributes to diffuse photons and further leads to image blurring in optical transillumination imaging.</p>
<p>Based on the preceding analysis of image dehazing model, and associated with the knowledge of light propagation through biological tissue, we propose a simplified skin scattering model to characterize the effects of skin scattering on finger-vein imaging, as shown in <xref ref-type="fig" rid="f5-sensors-12-03627">Figure 5</xref>.</p>
<p>Before presenting the mathematical expression, there are several points with respect to the optical model should be stated:
<list list-type="order">
<list-item>
<p>In a real finger-vein imaging system, the objects to be visualized are palm-side vein vessels which are mostly interspersed within the inner layer of the finger skin (see <xref ref-type="fig" rid="f6-sensors-12-03627">Figure 6(a)</xref>). So, for the sake of simplicity, only the skin layer is considered as a reference optical medium regardless of the atmosphere between skin surface and camera, whose scattering effect is very small and negligible here.</p></list-item>
<list-item>
<p>Human skin is known to be an inhomogeneous, multilayered tissue containing epidermis, dermis and subcutaneous layer, as shown in <xref ref-type="fig" rid="f6-sensors-12-03627">Figure 6(a)</xref>. But at the molecular level, skin tissues are composed of a limited number of basic molecular species, and these molecules are composed of optically similar chemical units [<xref ref-type="bibr" rid="b2-sensors-12-03627">2</xref>]. Moreover, the ensemble of light-skin interaction homogenizes the optical behavior of biological structures. Thus, the skin can be viewed as a medium with a random but homogeneous distribution of scattering particles over its thickness [<xref ref-type="bibr" rid="b26-sensors-12-03627">26</xref>], as shown in <xref ref-type="fig" rid="f6-sensors-12-03627">Figure 6(b)</xref>, and then the scattering coefficient of the skin tissue here can be assumed to be constant.</p></list-item>
<list-item>
<p>Different from the image dehazing techniques, we need not consider the effect of environmental illumination as well as the airlight indeed. Nevertheless, due to light interaction occurs among biological scatterers, the scattered radiation from both the object and the background will be partially re-scattered towards the observer, which amounts to environmental illumination for finger-vein imaging.</p></list-item></list></p>
<p>In view of these points, the radiant intensity observed at skin surface corresponding to the object with a certain depth in the skin can be simply decomposed into the direct attenuation component and the scattering component, as shown in <xref ref-type="fig" rid="f5-sensors-12-03627">Figure 5</xref>. The former, representing the effect of ballistic photons, is a reduction of the original radiation over the traversing medium, which obeys the Beer–Lambert law, while the latter represents the effect of snake and diffuse photons, namely a proportion of scattered radiation enters into the direction of observer and interferes with the direct radiation of object, whose intensity increases with depth because a deeper object tends to suffer more influence of the scattered radiation. Accordingly, in a similar way of Koschmieder model, the proposed biological optical model (BOM) is defined as
<disp-formula id="FD2">
<label>(2)</label>
<mml:math display="block">
<mml:mrow>
<mml:mi>I</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>p</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mi>e</mml:mi></mml:mrow>
<mml:mrow>
<mml:mo>−</mml:mo>
<mml:mi>μ</mml:mi>
<mml:mi>D</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:msup>
<mml:msub>
<mml:mrow>
<mml:mi>I</mml:mi></mml:mrow>
<mml:mn>0</mml:mn></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>+</mml:mo>
<mml:mo stretchy="false">(</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>−</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mi>e</mml:mi></mml:mrow>
<mml:mrow>
<mml:mo>−</mml:mo>
<mml:mi>μ</mml:mi>
<mml:mi>D</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:msup>
<mml:mo stretchy="false">)</mml:mo>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mi>r</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>where <italic>s</italic> represents an original source, <italic>p</italic> is the observation of <italic>s</italic> on the imaging plane, <italic>μ</italic> denotes the extinction coefficient of the skin tissue (assumed to be constant here). So, <italic>I</italic><sub>0</sub>(<italic>s</italic>) still represents the intrinsic intensity of the object, that is veins, to be visualized, <italic>I<sub>r</sub></italic>(<italic>s</italic>) denotes the intensity of scattered radiation, and <italic>I</italic>(<italic>p</italic>) is the observation of the vein object on the image plane. A key point needs to be noted that, different from the environmental illumination in atmosphere, <italic>I<sub>r</sub></italic>(<italic>s</italic>) varies spatially because its value is associated to the intensities of the imaging background. <xref ref-type="fig" rid="f7-sensors-12-03627">Figure 7</xref> schematically illustrates the effect of scattered radiation for intuitively understanding the relation between the proposed skin scattering model and a finger-vein image.</p>
<p>Assume that <italic>H</italic> denotes a small column in the skin tissue corresponding to a beam from the object point <italic>s</italic> to a point <italic>p</italic> on the image plane (each pixel corresponds to a small column), then the neighbor points (<italic>s<sup>′</sup><sub>i</sub></italic> ,<italic>i</italic> = 1, 2, ⋯ ,<italic>n</italic>) around <italic>s</italic> can be viewed as the local background radiation sources, which would emit radiation into the column <italic>H</italic> and produce the scattering component of the transmitted radiation along <italic>H</italic>. Let the original intensity of a neighbor point <italic>s<sup>′</sup><sub>i</sub></italic> be <italic>I</italic><sub>0</sub>(<italic>s<sup>′</sup><sub>i</sub></italic>), then the direct transmitted radiation of this point, that is the unscattered radiation, should be <italic>e</italic><sup>−</sup><italic><sup>μD</sup></italic><sup>(</sup><italic><sup>s′</sup><sub>i</sub></italic><sup>)</sup><italic>I</italic><sub>0</sub>(<italic>s<sup>′</sup><sub>i</sub></italic>). So, according to the energy conservation principle, the scattered radiation of this point should be (1 − <italic>e</italic><sup>−</sup><italic><sup>μD</sup></italic><sup>(</sup><italic><sup>s′</sup><sub>i</sub></italic><sup>)</sup>)<italic>I</italic><sub>0</sub>(<italic>s<sup>′</sup><sub>i</sub></italic>), where <italic>D</italic>(<italic>s<sup>′</sup><sub>i</sub></italic>) is the depth of point <italic>s<sup>′</sup><sub>i</sub></italic> in the skin layer. Thus, we can obtain the scattered radiation <italic>I<sub>r</sub></italic>(<italic>s</italic>) in <italic>H</italic>. Since the scattering directions are random, <italic>I<sub>r</sub></italic>(<italic>s</italic>) here is considered as an average of total radiation from overall neighbor points and rewritten as
<disp-formula id="FD3">
<label>(3)</label>
<mml:math display="block">
<mml:mrow>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mi>r</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mn>1</mml:mn>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>Z</mml:mi></mml:mrow>
<mml:mrow>
<mml:mi mathvariant="normal">Ω</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:msub></mml:mrow></mml:mfrac>
<mml:munder>
<mml:mo>∑</mml:mo>
<mml:mrow>
<mml:msubsup>
<mml:mi>s</mml:mi>
<mml:mi>i</mml:mi>
<mml:mo>′</mml:mo></mml:msubsup>
<mml:mo>∈</mml:mo>
<mml:mi mathvariant="normal">Ω</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:munder>
<mml:mrow>
<mml:mo stretchy="false">(</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>−</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mi>e</mml:mi></mml:mrow>
<mml:mrow>
<mml:mo>−</mml:mo>
<mml:mi>μ</mml:mi>
<mml:mi>D</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:msubsup>
<mml:mi>s</mml:mi>
<mml:mi>i</mml:mi>
<mml:mo>′</mml:mo></mml:msubsup>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:msup>
<mml:mo stretchy="false">)</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>I</mml:mi></mml:mrow>
<mml:mn>0</mml:mn></mml:msub></mml:mrow>
<mml:mo stretchy="false">(</mml:mo>
<mml:msubsup>
<mml:mi>s</mml:mi>
<mml:mi>i</mml:mi>
<mml:mo>′</mml:mo></mml:msubsup>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>where Ω(<italic>s</italic>) denotes the 2D neighborhood centered at point <italic>s</italic>, and <italic>Z</italic><sub>Ω</sub> indicates the number of points in Ω(<italic>s</italic>).</p>
<p>Given <italic>I<sub>r</sub></italic>(<italic>s</italic>), and <italic>D</italic>(<italic>s</italic>), we can obtain <italic>I</italic><sub>0</sub>(<italic>s</italic>) which represents the intrinsic intensity of a finger-vein image without scattering corruption. However, solving <italic>I</italic><sub>0</sub>(<italic>s</italic>) from a single observed image <italic>I</italic>(<italic>p</italic>) with <xref ref-type="disp-formula" rid="FD2">Equation (2)</xref> is a very ill-posed problem.</p></sec>
<sec>
<label>3.</label>
<title>Scattering Removal Algorithm</title>
<p>The values of <italic>I<sub>r</sub></italic>(<italic>s</italic>), <italic>μ</italic> and <italic>D</italic>(<italic>s</italic>) can not be evaluated accurately since the light scattering phenomenon in tissues is very complex. Not only is the extinct coefficient <italic>μ</italic> of human skin tissue inconsistent, but the thickness <italic>D</italic>(<italic>s</italic>) also varies with different individuals. Hence, referring to the image dehazing technique, we here introduce
<disp-formula id="FD4">
<label>(4)</label>
<mml:math display="block">
<mml:mrow>
<mml:mi>V</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:mo stretchy="false">(</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>−</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mi>e</mml:mi></mml:mrow>
<mml:mrow>
<mml:mo>−</mml:mo>
<mml:mi>μ</mml:mi>
<mml:mi>D</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:msup>
<mml:mo stretchy="false">)</mml:mo>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mi>r</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula><italic>V</italic> (<italic>s</italic>) can be regarded as the scattering component. Moreover, let <italic>T</italic> (<italic>s</italic>) = <italic>e</italic><sup>−</sup><italic><sup>μD</sup></italic><sup>(</sup><italic><sup>s</sup></italic><sup>)</sup> be the transmission map, we can obtain
<disp-formula id="FD5">
<label>(5)</label>
<mml:math display="block">
<mml:mrow>
<mml:mi>T</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>−</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>V</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mi>r</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mfrac>
<mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula><italic>T</italic> (<italic>s</italic>) describes the relative portion of light radiation surviving through a medium. Thus, the optical model can be rewritten as
<disp-formula id="FD6">
<label>(6)</label>
<mml:math display="block">
<mml:mrow>
<mml:mi>I</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>p</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:mi>T</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>I</mml:mi></mml:mrow>
<mml:mn>0</mml:mn></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>+</mml:mo>
<mml:mi>V</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>Instead of directly computing <italic>I</italic><sub>0</sub>(<italic>s</italic>), we first estimate the scattering component <italic>V</italic> (<italic>s</italic>), and then estimate the intensity of scattered radiation <italic>I<sub>r</sub></italic>(<italic>s</italic>). Thus, the restored image <italic>I</italic><sub>0</sub>(<italic>s</italic>) can be obtained based on <xref ref-type="disp-formula" rid="FD5">Equations (5)</xref> and <xref ref-type="disp-formula" rid="FD6">(6)</xref>.</p>
<sec>
<label>3.1.</label>
<title>Scattering Component Estimation</title>
<p>Unlike the regularized solution of scattering component estimation described in [<xref ref-type="bibr" rid="b17-sensors-12-03627">17</xref>], <italic>V</italic> (<italic>s</italic>) here varies locally and spatially on finger-vein imaging plane due to the heterogeneousness of the human skin tissue. Hence, three practical constraints should be introduced for <italic>V</italic> (<italic>s</italic>) and <italic>I<sub>r</sub></italic>(<italic>s</italic>) estimation: (1) For each point <italic>s</italic>, the intensity <italic>V</italic> (<italic>s</italic>) is positive and cannot be higher than the finally observed intensity <italic>I</italic>(<italic>p</italic>), that is, 0 <italic>≤ V</italic> (<italic>s</italic>) <italic>≤ I</italic>(<italic>p</italic>); (2) <italic>V</italic> (<italic>s</italic>) is smooth except the edges of venous regions since the points in Ω(<italic>s</italic>) approximate to be same in depth; (3) <italic>I<sub>r</sub></italic>(<italic>s</italic>) tends to be constant in Ω(<italic>s</italic>) and <italic>V</italic> (<italic>s</italic>) <italic>≤ I<sub>r</sub></italic>(<italic>s</italic>) <italic>≤ I</italic>(<italic>p</italic>). Based on these constraints, to estimate <italic>V</italic> (<italic>s</italic>), a fast algorithm described in [<xref ref-type="bibr" rid="b19-sensors-12-03627">19</xref>] is modified as
<disp-formula id="FD7">
<label>(7)</label>
<mml:math display="block">
<mml:mrow>
<mml:mi>V</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:mn>1</mml:mn>
<mml:mo>−</mml:mo>
<mml:mtext>max</mml:mtext>
<mml:mo stretchy="false">(</mml:mo>
<mml:mtext>min</mml:mtext>
<mml:mo stretchy="false">(</mml:mo>
<mml:msub>
<mml:mi>w</mml:mi>
<mml:mn>1</mml:mn></mml:msub>
<mml:mi>B</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>,</mml:mo>
<mml:mo> </mml:mo>
<mml:mover accent="true">
<mml:mi>I</mml:mi>
<mml:mo>^</mml:mo></mml:mover>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>p</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>,</mml:mo>
<mml:mo> </mml:mo>
<mml:mn>0</mml:mn>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>,</mml:mo></mml:mrow></mml:math></disp-formula>where <italic>B</italic>(<italic>s</italic>) = <italic>A</italic>(<italic>p</italic>) − <italic>median</italic><sub>Ω(</sub><italic><sub>p</sub></italic><sub>)</sub>(<italic>|Î</italic>(<italic>p</italic>) − <italic>A</italic>(<italic>p</italic>)<italic>|</italic>), <italic>A</italic>(<italic>p</italic>) = <italic>median</italic><sub>Ω(</sub><italic><sub>p</sub></italic><sub>)</sub>(<italic>Î</italic>(<italic>p</italic>)), Ω(<italic>p</italic>) denotes the 2D neighborhood centered at point <italic>p</italic>, <italic>w</italic><sub>1</sub> (<italic>∈</italic> [0, 1]) is a factor controlling the strength of the estimated scattering component, and <italic>Î</italic>(<italic>p</italic>) is the negative version of <italic>I</italic>(<italic>p</italic>). In <italic>Î</italic>(<italic>p</italic>), the venous regions become bright and can be viewed as fluorescent sources emitting light in transcutaneous manner, which is beneficial for modeling the light scattering component.</p></sec>
<sec>
<label>3.2.</label>
<title>Scattering Radiation Estimation</title>
<p>To obtain the transmission map <italic>T</italic> (<italic>s</italic>), we should compute <italic>I<sub>r</sub></italic>(<italic>s</italic>). Intuitively, we can obtain <italic>I<sub>r</sub></italic>(<italic>s</italic>) via <xref ref-type="disp-formula" rid="FD3">Equation (3)</xref> directly. However, it is a difficult task since the intrinsic intensity <italic>I</italic><sub>0</sub>(<italic>s<sup>′</sup><sub>i</sub></italic>) is unavailable in practice. Hence, considering the physical meaning that the scattered radiation <italic>I<sub>r</sub></italic>(<italic>s</italic>) depends on the interaction among neighbor points in Ω(<italic>s</italic>), we here simply use a local statistic of Ω(<italic>p</italic>) to represent <italic>I<sub>r</sub></italic>(<italic>s</italic>), that is,
<disp-formula id="FD8">
<label>(8)</label>
<mml:math display="block">
<mml:mrow>
<mml:msub>
<mml:mi>I</mml:mi>
<mml:mi>r</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>w</mml:mi>
<mml:mn>2</mml:mn></mml:msub></mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>Z</mml:mi></mml:mrow>
<mml:mrow>
<mml:mi mathvariant="normal">Ω</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>p</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:msub></mml:mrow></mml:mfrac>
<mml:munderover>
<mml:mo>∑</mml:mo>
<mml:mrow>
<mml:mi>i</mml:mi>
<mml:mo>=</mml:mo>
<mml:mn>1</mml:mn></mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>Z</mml:mi></mml:mrow>
<mml:mrow>
<mml:mi mathvariant="normal">Ω</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>p</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:msub></mml:mrow></mml:munderover>
<mml:mrow>
<mml:mi>I</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>p</mml:mi></mml:mrow>
<mml:mi>i</mml:mi></mml:msub>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>,</mml:mo></mml:mrow></mml:mrow></mml:math></disp-formula>where <italic>p<sub>i</sub> ∈</italic> Ω(<italic>p</italic>), <italic>Z</italic><sub>Ω(</sub><italic><sub>p</sub></italic><sub>)</sub> indicates the number of points in Ω(<italic>p</italic>), and <italic>w</italic><sub>2</sub> (<italic>∈</italic> [0, 1]) is a factor for making the constraint <italic>V</italic> (<italic>s</italic>) <italic>≤ I<sub>r</sub></italic>(<italic>s</italic>) <italic>≤ I</italic>(<italic>p</italic>) satisfying. So, based on <xref ref-type="disp-formula" rid="FD5">Equation (5)</xref>, we can estimate <italic>T</italic> (<italic>s</italic>) accordingly.</p></sec>
<sec>
<label>3.3.</label>
<title>Finger-vein Image Restoration</title>
<p>Given the estimations of <italic>V</italic> (<italic>s</italic>) and <italic>T</italic> (<italic>s</italic>), we can approximately restore an original finger-vein image with scattering removal. That is, by solving <xref ref-type="disp-formula" rid="FD6">Equation (6)</xref> with respect to <italic>I</italic><sub>0</sub>(<italic>s</italic>), we can obtain
<disp-formula id="FD9">
<label>(9)</label>
<mml:math display="block">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>I</mml:mi></mml:mrow>
<mml:mn>0</mml:mn></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:mi>I</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>p</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>−</mml:mo>
<mml:mi>V</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow>
<mml:mrow>
<mml:mi>T</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>s</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mfrac>
<mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>Thus, computing <italic>I</italic><sub>0</sub>(<italic>s</italic>) pixelwise using <xref ref-type="disp-formula" rid="FD9">Equation (9)</xref> can generate an image <italic>I</italic><sub>0</sub>(<italic>x, y</italic>) automatically and effectively. Here, <italic>I</italic><sub>0</sub>(<italic>x, y</italic>) represents the restored finger-vein image which appears free of multiple light scattering.</p></sec></sec>
<sec>
<label>4.</label>
<title>Finger-vein Image Matching</title>
<p>In this section, the Phase-Only-Correlation (POC) measure proposed in [<xref ref-type="bibr" rid="b27-sensors-12-03627">27</xref>] is simply used for handling the finger-vein matching problem based on the restored finger-vein images. Assume that <italic>I</italic><sub>0<sub><italic>i</italic></sub></sub> (<italic>x, y</italic>) and <italic>I</italic><sub>0<sub><italic>j</italic></sub></sub> (<italic>x, y</italic>) are two restored images, and <italic>F<sub>i</sub></italic>(<italic>u, v</italic>) and <italic>F<sub>j</sub></italic>(<italic>u, v</italic>) represent their 2D DFT, respectively, according to the property of Fourier transform, that is,
<disp-formula id="FD10">
<label>(10)</label>
<mml:math display="block">
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mi>I</mml:mi></mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mn>0</mml:mn></mml:mrow>
<mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:msub>
<mml:mo> </mml:mo>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>x</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>y</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>∘</mml:mo>
<mml:msub>
<mml:mrow>
<mml:mi>I</mml:mi></mml:mrow>
<mml:mrow>
<mml:msub>
<mml:mrow>
<mml:mn>0</mml:mn></mml:mrow>
<mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:msub>
<mml:mo> </mml:mo>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>x</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>y</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>⇔</mml:mo>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>i</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>v</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mover accent="true">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>j</mml:mi></mml:msub>
<mml:mo> </mml:mo>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>v</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>,</mml:mo></mml:mrow>
<mml:mo>¯</mml:mo></mml:mover></mml:mrow></mml:math></disp-formula>where “ ○ ” denotes a 2D correlation operator, we can compute the cross phase spectrum as
<disp-formula id="FD11">
<label>(11)</label>
<mml:math display="block">
<mml:mrow>
<mml:mi>R</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>v</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mo>=</mml:mo>
<mml:mfrac>
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>i</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>v</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mover accent="true">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>j</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>v</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow>
<mml:mo>¯</mml:mo></mml:mover></mml:mrow>
<mml:mrow>
<mml:mrow>
<mml:mo stretchy="false">‖</mml:mo>
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>i</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>v</mml:mi>
<mml:mo stretchy="false">)</mml:mo>
<mml:mover accent="true">
<mml:mrow>
<mml:msub>
<mml:mi>F</mml:mi>
<mml:mi>j</mml:mi></mml:msub>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>v</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow>
<mml:mo>¯</mml:mo></mml:mover></mml:mrow>
<mml:mo stretchy="false">‖</mml:mo></mml:mrow></mml:mrow></mml:mfrac>
<mml:mo>=</mml:mo>
<mml:msup>
<mml:mrow>
<mml:mi>e</mml:mi></mml:mrow>
<mml:mrow>
<mml:mover accent="true">
<mml:mi>j</mml:mi>
<mml:mo>^</mml:mo></mml:mover>
<mml:mi>θ</mml:mi>
<mml:mo stretchy="false">(</mml:mo>
<mml:mi>u</mml:mi>
<mml:mo>,</mml:mo>
<mml:mi>v</mml:mi>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:msup>
<mml:mo>.</mml:mo></mml:mrow></mml:math></disp-formula>Let <italic>r</italic>(<italic>x, y</italic>) = IDFT(<italic>R</italic>(<italic>u, v</italic>)), thus, <italic>r</italic>(<italic>x, y</italic>) is called a POC measure. The POC measure has a sharp peak when two restored finger-vein images are similar, whereas it will be near zero for those from different classes, as shown in <xref ref-type="fig" rid="f8-sensors-12-03627">Figure 8</xref>. Moreover, POC measure is insensitive to image shifts and noises in practice.</p></sec>
<sec sec-type="results">
<label>5.</label>
<title>Experimental Results</title>
<p>In this section, the used finger-vein images are captured by a homemade transillumination imaging system with a 760 nm NIR LED array source, and then extracted from raw images by the ROI localization and segmentation method proposed in [<xref ref-type="bibr" rid="b4-sensors-12-03627">4</xref>]. The finger-vein image database contains 700 individual finger-vein images from 70 individuals. Each individual contributes 10 forefinger-vein images of the right hand. All finger-vein images are 8-bit gray images with a resolution of 320 × 240.</p>
<sec>
<label>5.1.</label>
<title>Finger-vein Image Restoration</title>
<p>Here, some captured finger-vein image samples are collected to demonstrate the validity of the proposed method in finger-vein image restoration. <xref ref-type="fig" rid="f9-sensors-12-03627">Figure 9</xref> shows some examples of the estimated <italic>V</italic> (<italic>x, y</italic>), <italic>I<sub>r</sub></italic>(<italic>x, y</italic>), <italic>T</italic> (<italic>x, y</italic>) and restored finger-vein images <italic>I</italic><sub>0</sub>(<italic>x, y</italic>). After scattering removal, the contrast of finger-vein images is improved significantly, and the vein networks present in the restored images can be clearly distinguished from the background. This shows that the proposed optical model allowing for the effects of light scattering in skin layer, particularly the multiple scattering, is desirable for describing the mechanism of finger-vein image degradation.</p>
<p>Nevertheless, the proposed method is somewhat sensitive to image noises, as shown in <xref ref-type="fig" rid="f9-sensors-12-03627">Figure 9(e)</xref>. In fact, before lighting the palm-side veins, the NIR rays have been randomly diffused by finger dorsal tissues such as finger-back skin, bone, tendon, fatty tissue and so on. This inevitably gives rise to irregular shadows and noises in the captured finger-vein images, whereas the proposed optical model has not taken account of the effects of finger dorsal tissues except the palm-side skin. As a result, the spatial varied background noises are also strengthened when estimating the scattering components.</p>
<p>In <xref ref-type="fig" rid="f10-sensors-12-03627">Figure 10</xref>, we compare our method with several common approaches for finger-vein image enhancement. Additionally, we treat the degraded finger-vein images as hazing images, and directly use dehazing method to restore them regardless of the mismatch between the Koschmieder model and the proposed model. Here, a method proposed in [<xref ref-type="bibr" rid="b19-sensors-12-03627">19</xref>] is adopted to implement finger-vein image “dehazing”, and the results are also shown in <xref ref-type="fig" rid="f10-sensors-12-03627">Figure 10</xref>.</p>
<p>In order to evaluate the performance of the proposed method in terms of contrast improvement for finger-vein image, the mean structural similarity index (MSSIM) [<xref ref-type="bibr" rid="b12-sensors-12-03627">12</xref>] and the contrast improvement index (CII) [<xref ref-type="bibr" rid="b14-sensors-12-03627">14</xref>] are used as two common evaluation criterions. We first randomly choose 50 individual finger-vein images from database as samples, and use these enhancement methods in <xref ref-type="fig" rid="f10-sensors-12-03627">Figure 10</xref> to process the finger-vein image samples. Then, we obtain the average MSSIM and the average CII of every enhancement method.</p>
<p>In general, MSSIM is often used to measure the similarity between a processed image and a standard image with perfect quality (<italic>i.e.</italic>, a distortion-free image). The larger the value of MSSIM is, the better an image is improved. This makes a processed image more approximate to its standard quality. However, it is impossible for us to have standard or perfect finger-vein images since the captured images all are degraded due to light scattering. Therefore, we regard the degraded finger-vein images as standard references. Thus, the more the dissimilarity between a processed finger-vein image and its original version is, the better the finger-vein is improved. That is, the lower the value of MSSIM is, the better the quality of a restored image is. CII is often used to measure the improvement of contrast between a processed image and its original version, and the larger the value of CII is, the better the contrast of an improved image is.</p>
<p>Hence, the quality and the visibility of restored finger-vein images can be quantitatively evaluated using MSSIM and CII. In <xref ref-type="table" rid="t1-sensors-12-03627">Table 1</xref>, we list the two values corresponding to different finger-vein enhancement methods. From <xref ref-type="table" rid="t1-sensors-12-03627">Table 1</xref>, we can clearly see that the proposed method provides the lowest MSSIM value and the highest CII value. This means the proposed method has better performance in finger-vein image enhancement.</p></sec></sec>
<sec>
<label>5.2.</label>
<title>Finger-Vein Image Matching</title>
<p>For finger-vein matching on this database, the number of genuine attempts is 3,150 
<inline-formula>
<mml:math>
<mml:mrow>
<mml:mo stretchy="false">(</mml:mo>
<mml:mn>70</mml:mn>
<mml:msubsup>
<mml:mrow>
<mml:mi>C</mml:mi></mml:mrow>
<mml:mrow>
<mml:mn>10</mml:mn></mml:mrow>
<mml:mn>2</mml:mn></mml:msubsup>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:math></inline-formula>, and the number of impostor attempts is 241,500 
<inline-formula>
<mml:math>
<mml:mrow>
<mml:mo stretchy="false">(</mml:mo>
<mml:mn>10</mml:mn>
<mml:mo>×</mml:mo>
<mml:mn>10</mml:mn>
<mml:msubsup>
<mml:mrow>
<mml:mi>C</mml:mi></mml:mrow>
<mml:mrow>
<mml:mn>70</mml:mn></mml:mrow>
<mml:mn>2</mml:mn></mml:msubsup>
<mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:math></inline-formula>. By respectively using the original images, HTE-based images, HFEF-based images, CGF-based images, ImD-based images and the proposed restored images for finger-vein matching under POC (Phase-Only-Correlation) measure, the ROC (receiver operating characteristic) curves are plotted in <xref ref-type="fig" rid="f11-sensors-12-03627">Figure 11</xref>, where false non-match rates (FNMR) and false match rates (FMR) are shown in the same plot at different thresholds on the POC matching score, and EER (equal error rate) is the error rate where FNMR and FMR are equal.</p>
<p>From <xref ref-type="fig" rid="f11-sensors-12-03627">Figure 11</xref>, we can clearly see that the proposed method has the best performance of ROC curves and makes the lowest EER. This indicates that the finger-vein images with scattering removal are more discriminative in inter-class. Hence, the proposed method is desirable for improving the accuracy of finger-vein image matching in practice.</p></sec>
<sec sec-type="conclusions">
<label>6.</label>
<title>Conclusions</title>
<p>In this paper, a scattering removal method was introduced for finger-vein image restoration. The proposed method was based on a biological optical model which reasonably described the effects of skin scattering. In this model, the degradation of finger-vein images was viewed as a joint function of the direct light attenuation and multiple light scattering. By properly estimating the scattering components and transmission maps, the proposed method could effectively remove the effects of skin scattering effects from finger-vein images to obtain the restored results. The comparative experiments and quantitative evaluations demonstrated that the proposed method could provide better results compared to the common methods for finger-vein image enhancement and recognition.</p>
<p>Indeed, the proposed method also had its own drawbacks. First, the simplified model in our work did not take into account of the effects of background tissues, which made the proposed method somewhat sensitive to image noises while enhancing the vein patterns. Besides, the rough estimations of the scattering components as well as the scattered radiations could also decrease the performance of the proposed method to some extent. All these shortcomings will be of our further improvement in future work.</p></sec></body>
<back>
<ack>
<p>The authors would like to thank the National Natural Science Foundation of China (Project Grant No. 61073143) for supporting this study.</p></ack>
<ref-list>
<title>References</title>
<ref id="b1-sensors-12-03627"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kono</surname><given-names>M.</given-names></name><name><surname>Ueki</surname><given-names>H.</given-names></name><name><surname>Umemura</surname><given-names>S.</given-names></name></person-group><article-title>Near-infrared finger vein patterns for personal identification</article-title><source>Appl. Opt</source><year>2002</year><volume>41</volume><fpage>7429</fpage><lpage>7436</lpage><pub-id pub-id-type="doi">10.1364/AO.41.007429</pub-id><pub-id pub-id-type="pmid">12502300</pub-id></citation></ref>
<ref id="b2-sensors-12-03627"><label>2.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Backman</surname><given-names>V.</given-names></name><name><surname>Wax</surname><given-names>A.</given-names></name></person-group><article-title>Classical light scattering models</article-title><source>Biomedical Applications of Light Scattering</source><person-group person-group-type="editor"><name><surname>Wax</surname><given-names>A.</given-names></name><name><surname>Backman</surname><given-names>V.</given-names></name></person-group><publisher-name>McGraw-Hill</publisher-name><publisher-loc>New York, NY, USA</publisher-loc><year>2010</year><fpage>3</fpage><lpage>29</lpage></citation></ref>
<ref id="b3-sensors-12-03627"><label>3.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Sprawls</surname><given-names>P.</given-names></name></person-group><article-title>Scattered Radiation and Contrast</article-title><source>The Physical Principles of Medical Imaging</source><edition>2nd ed</edition><publisher-name>Aspen Publishers</publisher-name><publisher-loc>New York, NY, USA</publisher-loc><year>1993</year><comment>Available online: <ext-link xlink:href="http://www.sprawls.org/ppmi2/SCATRAD/" ext-link-type="uri">http://www.sprawls.org/ppmi2/SCATRAD/</ext-link> (accessed on 5 January 2012).</comment></citation></ref>
<ref id="b4-sensors-12-03627"><label>4.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Yang</surname><given-names>J.F.</given-names></name><name><surname>Li</surname><given-names>X.</given-names></name></person-group><article-title>Efficient Finger vein Localization and Recognition</article-title><conf-name>Proceedings of the 20th International Conference on Pattern Recognition (ICPR 2010)</conf-name><conf-loc>Istanbul, Turkey</conf-loc><conf-date>23–26 August 2010</conf-date><fpage>1148</fpage><lpage>1151</lpage></citation></ref>
<ref id="b5-sensors-12-03627"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wen</surname><given-names>X.B.</given-names></name><name><surname>Zhao</surname><given-names>J.W.</given-names></name><name><surname>Liang</surname><given-names>X.Z.</given-names></name></person-group><article-title>Image enhancement of finger-vein patterns based on wavelet denoising and histogram template equalization (in Chinese)</article-title><source>J. Jilin Univ. (Sci. Ed.)</source><year>2008</year><volume>46</volume><fpage>291</fpage><lpage>292</lpage></citation></ref>
<ref id="b6-sensors-12-03627"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhao</surname><given-names>J.J.</given-names></name><name><surname>Xiong</surname><given-names>X.</given-names></name><name><surname>Zhang</surname><given-names>L.</given-names></name><name><surname>Fu</surname><given-names>T.</given-names></name><name><surname>Zhao</surname><given-names>Y.X.</given-names></name></person-group><article-title>Study on enhanced algorithm of hand vein image based on CLAHE and Top-hat transform (in Chinese)</article-title><source>Laser Infrared</source><year>2009</year><volume>39</volume><fpage>220</fpage><lpage>222</lpage></citation></ref>
<ref id="b7-sensors-12-03627"><label>7.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Yang</surname><given-names>J.F.</given-names></name><name><surname>Yang</surname><given-names>J.L.</given-names></name><name><surname>Shi</surname><given-names>Y.H.</given-names></name></person-group><article-title>Combination of Gabor Wavelets and Circular Gabor Filter for Finger-vein Extraction</article-title><conf-name>Proceedings of the 5th International Conference on Intelligent Computing (ICIC 2009)</conf-name><conf-loc>Ulsan, South Korea</conf-loc><conf-date>16–19 September 2009</conf-date><source>Emerging Intelligent Computing Technology and Applications (LNCS 5754)</source><person-group person-group-type="editor"><name><surname>Huang</surname><given-names>D.S.</given-names></name><name><surname>Jo</surname><given-names>K.H.</given-names></name><name><surname>Lee</surname><given-names>H.H.</given-names></name><etal/></person-group><publisher-name>Springer-Verlag</publisher-name><publisher-loc>Berlin/Heidelberg, Germany</publisher-loc><year>2009</year><fpage>346</fpage><lpage>354</lpage></citation></ref>
<ref id="b8-sensors-12-03627"><label>8.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Yang</surname><given-names>J.F.</given-names></name><name><surname>Yang</surname><given-names>J.L.</given-names></name></person-group><article-title>Multi-Channel Gabor Filter Design for Finger-vein Image Enhancement</article-title><conf-name>Proceedings of the 5th International Conference on Image and Graphics (ICIG’ 09)</conf-name><conf-loc>Xi’an, China</conf-loc><conf-date>20–23 September 2009</conf-date><fpage>87</fpage><lpage>91</lpage></citation></ref>
<ref id="b9-sensors-12-03627"><label>9.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Yang</surname><given-names>J.F.</given-names></name><name><surname>Yan</surname><given-names>M.F.</given-names></name></person-group><article-title>An Improved Method for Finger-vein Image Enhancement</article-title><conf-name>Proceedings of IEEE 10th International Conference on Signal Processing (ICSP 2010)</conf-name><conf-loc>Beijing, China</conf-loc><conf-date>24–28 October 2010</conf-date><fpage>1706</fpage><lpage>1709</lpage></citation></ref>
<ref id="b10-sensors-12-03627"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname><given-names>K.J.</given-names></name><name><surname>Ma</surname><given-names>H.</given-names></name><name><surname>Li</surname><given-names>X.F.</given-names></name><name><surname>Guan</surname><given-names>F.X.</given-names></name><name><surname>Liu</surname><given-names>J.Y.</given-names></name></person-group><article-title>Finger vein pattern extraction method using oriented filtering technology (in Chinese)</article-title><source>J. Image Graph</source><year>2011</year><volume>16</volume><fpage>1206</fpage><lpage>1212</lpage></citation></ref>
<ref id="b11-sensors-12-03627"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname><given-names>K.J.</given-names></name><name><surname>Fu</surname><given-names>B.</given-names></name><name><surname>Xiong</surname><given-names>X.Y.</given-names></name></person-group><article-title>A novel adaptive vein image contrast enhancement method based on fuzzy and retinex theory (in Chinese)</article-title><source>Tech. Automation Appl</source><year>2009</year><volume>28</volume><fpage>72</fpage><lpage>75</lpage></citation></ref>
<ref id="b12-sensors-12-03627"><label>12.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Pi</surname><given-names>W.</given-names></name><name><surname>Shin</surname><given-names>J.O</given-names></name><name><surname>Park</surname><given-names>D.S.</given-names></name></person-group><article-title>An Effective Quality Improvement Approach for Low Quality Finger vein Image</article-title><conf-name>Proceedings of International Conference on Electronics and Information Engineering (ICEIE 2010)</conf-name><conf-loc>Kyoto, Japan</conf-loc><conf-date>1–2 August 2010</conf-date><fpage>V1-424-427</fpage></citation></ref>
<ref id="b13-sensors-12-03627"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gao</surname><given-names>X.Y.</given-names></name><name><surname>Ma</surname><given-names>J.S.</given-names></name><name><surname>Wu</surname><given-names>J.J.</given-names></name></person-group><article-title>The research of finger-vein image enhancement algorithm (in Chinese)</article-title><source>Opt. Instrum</source><year>2010</year><volume>32</volume><fpage>29</fpage><lpage>32</lpage></citation></ref>
<ref id="b14-sensors-12-03627"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Oh</surname><given-names>J.S.</given-names></name><name><surname>Hwang</surname><given-names>H.S.</given-names></name></person-group><article-title>Feature enhancement of medical images using morphology-based homomorphic filter and differential evolution algorithm</article-title><source>Int. J. Control Automation Syst</source><year>2010</year><volume>8</volume><fpage>857</fpage><lpage>861</lpage><pub-id pub-id-type="doi">10.1007/s12555-010-0418-y</pub-id></citation></ref>
<ref id="b15-sensors-12-03627"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cheong</surname><given-names>W.F.</given-names></name><name><surname>Prahl</surname><given-names>S.A.</given-names></name><name><surname>Welch</surname><given-names>A.J.</given-names></name></person-group><article-title>A review of the optical properties of biological tissues</article-title><source>IEEE J. Quantum Electron</source><year>1990</year><volume>26</volume><fpage>12:2166</fpage><lpage>2185</lpage></citation></ref>
<ref id="b16-sensors-12-03627"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Narasimhan</surname><given-names>S.G.</given-names></name><name><surname>Nayar</surname><given-names>S.K.</given-names></name></person-group><article-title>Contrast restoration of weather degraded images</article-title><source>IEEE Trans. Pattern Anal. Mach. Intell</source><year>2003</year><volume>25</volume><fpage>713</fpage><lpage>724</lpage><pub-id pub-id-type="doi">10.1109/TPAMI.2003.1201821</pub-id></citation></ref>
<ref id="b17-sensors-12-03627"><label>17.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Tan</surname><given-names>R.T.</given-names></name></person-group><article-title>Visibility in Bad Weather from a Single Image</article-title><conf-name>Proceedings of IEEE Conference on Computer Vision and Pattern Recognition (CVPR 2008)</conf-name><conf-loc>Anchorage, AK, USA</conf-loc><conf-date>23–28 June 2008</conf-date><fpage>1</fpage><lpage>8</lpage></citation></ref>
<ref id="b18-sensors-12-03627"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fattal</surname><given-names>R.</given-names></name></person-group><article-title>Single image dehazing</article-title><source>ACM Trans. Graph. (TOG)</source><year>2008</year><volume>27</volume><fpage>72:1</fpage><lpage>72:9</lpage></citation></ref>
<ref id="b19-sensors-12-03627"><label>19.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Tarel</surname><given-names>J.-P.</given-names></name><name><surname>Hautière</surname><given-names>N.</given-names></name></person-group><article-title>Fast Visibility Restoration from a Single Color or Gray Level Image</article-title><conf-name>Proceedings of IEEE 12th International Conference on Computer Vision (ICCV 09)</conf-name><conf-loc>Kyoto, Japan</conf-loc><conf-date>29 September–2 October 2009</conf-date><fpage>2201</fpage><lpage>2208</lpage></citation></ref>
<ref id="b20-sensors-12-03627"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>He</surname><given-names>K.M.</given-names></name><name><surname>Sun</surname><given-names>J.</given-names></name><name><surname>Tang</surname><given-names>X.O.</given-names></name></person-group><article-title>Single image haze removal using dark channel prior</article-title><source>IEEE Trans. Pattern Anal. Mach. Intell</source><year>2011</year><volume>33</volume><fpage>2341</fpage><lpage>2353</lpage><pub-id pub-id-type="doi">10.1109/TPAMI.2010.168</pub-id></citation></ref>
<ref id="b21-sensors-12-03627"><label>21.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Dumont</surname><given-names>E.</given-names></name><name><surname>Hautière</surname><given-names>N.</given-names></name><name><surname>Gallen</surname><given-names>R.</given-names></name></person-group><article-title>A Semi-Analytic Model of Fog Effects on Vision</article-title><source>Atmospheric Turbulence, Meteorological Modeling and Aerodynamics</source><person-group person-group-type="editor"><name><surname>Lang</surname><given-names>P.R.</given-names></name><name><surname>Lombargo</surname><given-names>F.S.</given-names></name></person-group><publisher-name>Nova Science Publishers</publisher-name><publisher-loc>New York, NY, USA</publisher-loc><year>2011</year><fpage>635</fpage><lpage>670</lpage></citation></ref>
<ref id="b22-sensors-12-03627"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Narasimhan</surname><given-names>S.G.</given-names></name><name><surname>Nayar</surname><given-names>S.K.</given-names></name></person-group><article-title>Vision and the atmosphere</article-title><source>Int. J. Comput. Vis</source><year>2002</year><volume>48</volume><fpage>233</fpage><lpage>254</lpage><pub-id pub-id-type="doi">10.1023/A:1016328200723</pub-id></citation></ref>
<ref id="b23-sensors-12-03627"><label>23.</label><citation citation-type="other"><person-group person-group-type="author"><name><surname>Hollis</surname><given-names>V.</given-names></name></person-group><article-title>Non-Invasive Monitoring of Brain Tissue Temperature by Near-Infrared Spectroscopy</article-title><comment>Ph.D. Dissertation,</comment><publisher-name>University of London</publisher-name><publisher-loc>London, UK</publisher-loc><fpage>2002</fpage></citation></ref>
<ref id="b24-sensors-12-03627"><label>24.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Prasad</surname><given-names>P.N.</given-names></name></person-group><article-title>Bioimaging: Principles and Techniques</article-title><source>Introduction to Biophotonics</source><publisher-name>John Wiley &amp; Sons</publisher-name><publisher-loc>New York, NY, USA</publisher-loc><year>2003</year><fpage>203</fpage><lpage>209</lpage></citation></ref>
<ref id="b25-sensors-12-03627"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ramachandran</surname><given-names>H.</given-names></name></person-group><article-title>Imaging through turbid media</article-title><source>Current Sci</source><year>1999</year><volume>76</volume><fpage>1334</fpage><lpage>1340</lpage></citation></ref>
<ref id="b26-sensors-12-03627"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Van Gemert</surname><given-names>M.J.C.</given-names></name><name><surname>Jacques</surname><given-names>S.L.</given-names></name><name><surname>Sterenborg</surname><given-names>H.J.C.M.</given-names></name><name><surname>Star</surname><given-names>W.M.</given-names></name></person-group><article-title>Skin optics</article-title><source>IEEE Trans. Biomed. Eng</source><year>1989</year><volume>36</volume><fpage>1146</fpage><lpage>1154</lpage><pub-id pub-id-type="doi">10.1109/10.42108</pub-id><pub-id pub-id-type="pmid">2606488</pub-id></citation></ref>
<ref id="b27-sensors-12-03627"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ito</surname><given-names>K.</given-names></name><name><surname>Nakajima</surname><given-names>H.</given-names></name><name><surname>Kobayashi</surname><given-names>K.</given-names></name><name><surname>Aoki</surname><given-names>T.</given-names></name><name><surname>Higuchi</surname><given-names>T.</given-names></name></person-group><article-title>A fingerprint matching algorithm using phase-only correlation</article-title><source>IEICE Trans. Fundamentals</source><year>2004</year><volume>E87-A(3)</volume><fpage>682</fpage><lpage>691</lpage></citation></ref></ref-list>
<sec sec-type="display-objects">
<title>Figures and Table</title>
<fig id="f1-sensors-12-03627" position="float">
<label>Figure 1.</label>
<caption>
<p>Finger-vein image acquisition system. (<bold>a</bold>) NIR light transillumination. (<bold>b</bold>) A homemade finger-vein imaging device. (<bold>c</bold>) ROI extraction proposed in [<xref ref-type="bibr" rid="b4-sensors-12-03627">4</xref>].</p></caption>
<graphic xlink:href="sensors-12-03627f1.gif"/></fig>
<fig id="f2-sensors-12-03627" position="float">
<label>Figure 2.</label>
<caption>
<p>Image contrast reduction due to light scattering. (<bold>a</bold>) A real shadow as no light scattering. (<bold>b</bold>) A degraded shadow as light scattering.</p></caption>
<graphic xlink:href="sensors-12-03627f2.gif"/></fig>
<fig id="f3-sensors-12-03627" position="float">
<label>Figure 3.</label>
<caption>
<p>Effects of atmospheric scattering.</p></caption>
<graphic xlink:href="sensors-12-03627f3.gif"/></fig>
<fig id="f4-sensors-12-03627" position="float">
<label>Figure 4.</label>
<caption>
<p>Light propagation through biological tissue.</p></caption>
<graphic xlink:href="sensors-12-03627f4.gif"/></fig>
<fig id="f5-sensors-12-03627" position="float">
<label>Figure 5.</label>
<caption>
<p>Simplified skin scattering model.</p></caption>
<graphic xlink:href="sensors-12-03627f5.gif"/></fig>
<fig id="f6-sensors-12-03627" position="float">
<label>Figure 6.</label>
<caption>
<p>Skin layer modeling. (<bold>a</bold>) Cross-sectional view of human skin. (<bold>b</bold>) Simplified model of finger palm-side skin layer.</p></caption>
<graphic xlink:href="sensors-12-03627f6.gif"/></fig>
<fig id="f7-sensors-12-03627" position="float">
<label>Figure 7.</label>
<caption>
<p>Schematic representation of the effect of scattered radiation.</p></caption>
<graphic xlink:href="sensors-12-03627f7.gif"/></fig>
<fig id="f8-sensors-12-03627" position="float">
<label>Figure 8.</label>
<caption>
<p>POC measure. Left: <italic>r</italic>(<italic>x, y</italic>) of two same finger-vein images. Right: <italic>r</italic>(<italic>x, y</italic>) of two finger-vein images from different classes.</p></caption>
<graphic xlink:href="sensors-12-03627f8.gif"/></fig>
<fig id="f9-sensors-12-03627" position="float">
<label>Figure 9.</label>
<caption>
<p>Scattering removal experiments. (<bold>a</bold>) Some captured finger-vein images <italic>I</italic>(<italic>x, y</italic>). (<bold>b</bold>) The estimated scattering components <italic>V</italic> (<italic>x, y</italic>). (<bold>c</bold>) The estimated scattering radiations <italic>I<sub>r</sub></italic>(<italic>x, y</italic>). (<bold>d</bold>) The estimated transmission maps <italic>T</italic> (<italic>x, y</italic>). (<bold>e</bold>) The restored images <italic>I</italic><sub>0</sub>(<italic>x, y</italic>).</p></caption>
<graphic xlink:href="sensors-12-03627f9.gif"/></fig>
<fig id="f10-sensors-12-03627" position="float">
<label>Figure 10.</label>
<caption>
<p>Comparisons with other methods. (<bold>a</bold>) Some captured finger-vein images. (<bold>b</bold>) The results from histogram template equalization (HTE) [<xref ref-type="bibr" rid="b5-sensors-12-03627">5</xref>]. (<bold>c</bold>) The results from high frequency emphasis filtering (HFEF) [<xref ref-type="bibr" rid="b13-sensors-12-03627">13</xref>]. (<bold>d</bold>) The results from circular Gabor filtering (CGF) [<xref ref-type="bibr" rid="b7-sensors-12-03627">7</xref>]. (<bold>e</bold>) The results from image dehazing (ImD) [<xref ref-type="bibr" rid="b19-sensors-12-03627">19</xref>]. (<bold>f</bold>) The results from the proposed method.</p></caption>
<graphic xlink:href="sensors-12-03627f10.gif"/></fig>
<fig id="f11-sensors-12-03627" position="float">
<label>Figure 11.</label>
<caption>
<p>ROC curves of different finger-vein enhancement results.</p></caption>
<graphic xlink:href="sensors-12-03627f11.gif"/></fig>
<table-wrap id="t1-sensors-12-03627" position="float">
<label>Table 1.</label>
<caption>
<p>Quantitative evaluation of different enhancement methods.</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="center" valign="middle">Methods</th>
<th align="center" valign="middle">Average MSSIM</th>
<th align="center" valign="middle">Average CII</th></tr></thead>
<tbody>
<tr>
<td align="center" valign="top">The captured images</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top">1</td></tr>
<tr>
<td align="center" valign="top">Histogram Template Equalization (HTE)</td>
<td align="center" valign="top">0.4076</td>
<td align="center" valign="top">4.4941</td></tr>
<tr>
<td align="center" valign="top">High Frequency Emphasis Filtering (HFEF)</td>
<td align="center" valign="top">0.4239</td>
<td align="center" valign="top">3.7571</td></tr>
<tr>
<td align="center" valign="top">Circular Gabor Filtering (CGF)</td>
<td align="center" valign="top">0.4141</td>
<td align="center" valign="top">3.7386</td></tr>
<tr>
<td align="center" valign="top">Image Dehazing (ImD)</td>
<td align="center" valign="top">0.4932</td>
<td align="center" valign="top">3.3967</td></tr>
<tr>
<td align="center" valign="top">The Proposed Method</td>
<td align="center" valign="top">0.3358</td>
<td align="center" valign="top">4.6210</td></tr></tbody></table></table-wrap></sec></back></article>