<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="en" article-type="review-article">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Sensors</journal-id>
<journal-title>Sensors</journal-title>
<issn pub-type="epub">1424-8220</issn>
<publisher>
<publisher-name>Molecular Diversity Preservation International (MDPI)</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3390/s110505087</article-id>
<article-id pub-id-type="publisher-id">sensors-11-05087</article-id>
<article-categories>
<subj-group>
<subject>Review</subject></subj-group></article-categories>
<title-group>
<article-title>Protein Biosensors Based on Polymer Nanowires, Carbon Nanotubes and Zinc Oxide Nanorods</article-title></title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>M.</surname><given-names>Anish Kumar</given-names></name><xref ref-type="aff" rid="af1-sensors-11-05087"><sup>1</sup></xref></contrib>
<contrib contrib-type="author">
<name><surname>Jung</surname><given-names>Soyoun</given-names></name><xref ref-type="aff" rid="af2-sensors-11-05087"><sup>2</sup></xref></contrib>
<contrib contrib-type="author">
<name><surname>Ji</surname><given-names>Taeksoo</given-names></name><xref ref-type="aff" rid="af1-sensors-11-05087"><sup>1</sup></xref><xref ref-type="aff" rid="af2-sensors-11-05087"><sup>2</sup></xref><xref ref-type="corresp" rid="c1-sensors-11-05087"><sup>*</sup></xref></contrib></contrib-group>
<aff id="af1-sensors-11-05087">
<label>1</label> Microelectronics Photonics, University of Arkansas, Fayetteville, AR 72701, USA; E-Mail: <email>manoanish123@gmail.com</email></aff>
<aff id="af2-sensors-11-05087">
<label>2</label> Department of Electrical Engineering, University of Arkansas, Fayetteville, AR 72701, USA; E-Mail: <email>soyounj@yahoo.com</email></aff>
<author-notes>
<corresp id="c1-sensors-11-05087">
<label>*</label>Author to whom correspondence should be addressed; E-Mail: <email>tji@uark.edu</email>; Tel.: +1-479-575-6586; Fax: +1-479-575-7967.</corresp></author-notes>
<pub-date pub-type="collection">
<year>2011</year></pub-date>
<pub-date pub-type="epub">
<day>9</day>
<month>5</month>
<year>2011</year></pub-date>
<volume>11</volume>
<fpage>5087</fpage>
<lpage>5111</lpage>
<history>
<date date-type="received">
<day>13</day>
<month>4</month>
<year>2011</year></date>
<date date-type="rev-recd">
<day>3</day>
<month>5</month>
<year>2011</year></date>
<date date-type="accepted">
<day>5</day>
<month>5</month>
<year>2011</year></date></history>
<permissions>
<copyright-statement>© 2011 by the authors; licensee MDPI, Basel, Switzerland.</copyright-statement>
<copyright-year>2011</copyright-year>
<license>
<p>This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).</p></license></permissions>
<abstract>
<p>The development of biosensors using electrochemical methods is a promising application in the field of biotechnology. High sensitivity sensors for the bio-detection of proteins have been developed using several kinds of nanomaterials. The performance of the sensors depends on the type of nanostructures with which the biomaterials interact. One dimensional (1-D) structures such as nanowires, nanotubes and nanorods are proven to have high potential for bio-applications. In this paper we review these three different kinds of nanostructures that have attracted much attention at recent times with their great performance as biosensors. Materials such as polymers, carbon and zinc oxide have been widely used for the fabrication of nanostructures because of their enhanced performance in terms of sensitivity, biocompatibility, and ease of preparation. Thus we consider polymer nanowires, carbon nanotubes and zinc oxide nanorods for discussion in this paper. We consider three stages in the development of biosensors: (a) fabrication of biomaterials into nanostructures, (b) alignment of the nanostructures and (c) immobilization of proteins. Two different methods by which the biosensors can be developed at each stage for all the three nanostructures are examined. Finally, we conclude by mentioning some of the major challenges faced by many researchers who seek to fabricate biosensors for real time applications.</p></abstract>
<kwd-group>
<kwd>biosensor</kwd>
<kwd>nanostructures</kwd>
<kwd>electrochemical</kwd>
<kwd>immobilization</kwd></kwd-group></article-meta></front>
<body>
<sec sec-type="intro">
<label>1.</label>
<title>Introduction</title>
<p>A biosensor is in general an analytical device that responds to biological detection of proteins in the form of electrical signals [<xref ref-type="bibr" rid="b1-sensors-11-05087">1</xref>]. It can also be defined as a device in which the response of some chemical biomatrix such as antibodies, enzymes <italic>etc.</italic> is modified into an electrical signal depending on the concentration of the analyte used [<xref ref-type="bibr" rid="b2-sensors-11-05087">2</xref>]. Typically, a biosensor is comprised of a transducer part and a sensing part. The detector part is the one that detects the target cells in the body and the transducer collects the information from the detector and transmits a signal to the output system. The detector part is usually a protein or an enzyme that captures the target cells, while the major part of the sensor is the transducer which changes the characteristics of the whole sensor and allows researchers to develop an effective biosensor so that it can be implanted into a human body. The structure of the transducer part is the main factor that will decide the number of available protein binding sites.</p>
<p>In recent times, one dimensional nanostructures such as nanowires, nanotubes and nanobelts have attracted a great attention in the construction of biosensors due to their unique properties and potential to be fabricated as sensors [<xref ref-type="bibr" rid="b3-sensors-11-05087">3</xref>]. With a large surface/volume ratio and a Debye length comparable to the nanostructure radius, the electronic properties of these nanostructures are strongly influenced by surface processes, giving rise to superior sensitivity than their thin film counterparts. In comparison with 2-D films, where the charges are accumulated on the surface, the charge accumulation in 1-D nanostructures occurs in the bulk of the material, which ensures good electrical properties during detection. The 1-D nanostructures are most commonly fabricated by a bottom-up approach using synthesis processes. A bottom-up approach is nothing but a chemical reaction that is done using particular reactants under specific conditions. It basically requires a catalyst, a vapor phase reactant (nanostructure material) and a thermal environment to effectively synthesize the nanomaterials. These 1-D nanostructures are chosen particularly due to their high response to external stimulus that can be used for real time monitoring applications [<xref ref-type="bibr" rid="b4-sensors-11-05087">4</xref>–<xref ref-type="bibr" rid="b11-sensors-11-05087">11</xref>].</p>
<p>In this paper we review three main kinds of 1-D nanostructures, as mentioned above. The review concentrates particularly on materials such as polymers, carbon and zinc oxide (ZnO) that can be fabricated in these 1-D nanostructure forms. The materials that can be molded into these nanostructures play a key role, especially, for bio-applications. There are various methods by which these nanomaterials can be fabricated, aligned and used to immobilize proteins. Here we first discuss the materials used for fabricating nanostructures, followed by the techniques used during the three different stages of biosensor fabrication.</p>
<p>Conducting polymers (CPs) that possesses high electrical conductivity due to their π conjugated electrons are one of the more promising biocompatible materials and have been used in various applications [<xref ref-type="bibr" rid="b12-sensors-11-05087">12</xref>–<xref ref-type="bibr" rid="b15-sensors-11-05087">15</xref>]. Thus, they have been used as a transducer in biological sensors because of their attractive properties such as high stability at room temperature, good conductivity output and facile polymerization [<xref ref-type="bibr" rid="b16-sensors-11-05087">16</xref>]. Another important advantage of using CPs is that the biomolecules can be immobilized onto the nanowire structure in a single step rather than the multiple steps that are required when other non-polymeric materials are used. In addition, the electrochemically prepared CPs can be grown with controlled thickness using lower potential and they also have an excellent enzyme-entrapping capability [<xref ref-type="bibr" rid="b17-sensors-11-05087">17</xref>–<xref ref-type="bibr" rid="b20-sensors-11-05087">20</xref>].</p>
<p>Another successful 1-D nanostructure in the field of biosensors is the carbon nanotube (CNT). These exhibit very long and slender shaped structures with high surface area, hexagonal networks, and unique C-C covalent bonding which makes them attractive in the field of biosensors [<xref ref-type="bibr" rid="b21-sensors-11-05087">21</xref>]. The CNTs were used in the field of biosensor in order to introduce a new material than the ones that already exists. This led to the preparation of CNTs using chemical methods so that the immobilization of biomolecules could be done in a reliable manner [<xref ref-type="bibr" rid="b22-sensors-11-05087">22</xref>]. Additionally, organic molecules integrated with nanotubes are believed to offer new research fields and applications such as <italic>in vivo</italic> implantation of the device [<xref ref-type="bibr" rid="b23-sensors-11-05087">23</xref>].</p>
<p>Zinc oxide is a fairly recent material on which the research is being concentrated to develop it as a biosensor. ZnO had some different issues when fabricated in nanostructures than when used in a planar device. Since the nanostructures that are built using the bottom-up approach can be made to work as a biosensor system, many attempts in this direction have been made at recent times [<xref ref-type="bibr" rid="b24-sensors-11-05087">24</xref>,<xref ref-type="bibr" rid="b25-sensors-11-05087">25</xref>]. Properties such as the high isoelectric point (9.5) and fast electron transfer [<xref ref-type="bibr" rid="b26-sensors-11-05087">26</xref>] observed in ZnO nanowires are also a reason for these attempts. Thus, it is believed that the usage of this material as a biosensor will also be successful in the coming years.</p></sec>
<sec>
<label>2.</label>
<title>Biosensor Development Using Polymer Nanowires</title>
<p>Polypyrrole, a conducting polymer which is more conductive, stable and biocompatible than other polymer materials is reviewed in this paper. In 1916, polymerization of the monomer was first done by a research group [<xref ref-type="bibr" rid="b27-sensors-11-05087">27</xref>] who oxidized it into a fine black amorphous powder and named it “pyrrole black”. Later, these monomers were grown by controlling the thickness of the polymer film [<xref ref-type="bibr" rid="b28-sensors-11-05087">28</xref>], which attracted a great deal of attention from many researchers in the biomedical applications field [<xref ref-type="bibr" rid="b29-sensors-11-05087">29</xref>]. At present, nanosize polypyrrole is grown, which allows even a very low current to pass through, making the device even compatible with the human body. According to [<xref ref-type="bibr" rid="b30-sensors-11-05087">30</xref>], electrochemically prepared pyrroles are more conductive and stable when compared to the chemically prepared ones.</p>
<sec>
<label>2.1.</label>
<title>Synthesis of Polymer Nanowires</title>
<p>In 1991, Wei <italic>et al</italic>. followed a method which led to the production of polypyrrole powder. After this attempt, they tried to prepare the powder at an increasing rate and as a doped and conductive form using chemical polymerization techniques [<xref ref-type="bibr" rid="b30-sensors-11-05087">30</xref>]. This kindled the notion of upgrading the material and using it in various applications. They were initially prepared using the slip casting and sol gel methods [<xref ref-type="bibr" rid="b31-sensors-11-05087">31</xref>], involving very complex and time consuming processes, but nowadays the synthesis of the polymers is done electrochemically since the fabrication process is simple and cost effective, requiring just a porous template of some electrically insulating material. According to [<xref ref-type="bibr" rid="b32-sensors-11-05087">32</xref>], the growth of polymer nanowires can also be done using the track edge method, printing techniques, photochemical lithography, edge lithography and micromolding [<xref ref-type="bibr" rid="b33-sensors-11-05087">33</xref>]. However, these techniques are all very complex and require very costly equipment for the preparation of nanowires.</p>
<p>For instance, micromolding is one of the most effective techniques for fabricating nanowires with high aspect ratio [<xref ref-type="bibr" rid="b33-sensors-11-05087">33</xref>]. In this method, an initial polydimethylsiloxane (PDMS) mold which is the master is produced with the desired length, radius and pitch (distance between nanowires) using a photolighraphy process. Then an antisticking layer—PDMS or paraffin—is poured into the master and cured for a few hours and later peeled off. This antisticking layer is shown in the <xref ref-type="fig" rid="f1-sensors-11-05087">Figure 1(D)</xref>. A SEM image of the negative PDMS mold onto which the polymer solution is poured along with a supporting liquid metal such that the holes are filled up with the liquid can be seen in <xref ref-type="fig" rid="f1-sensors-11-05087">Figure 1(E)</xref>.</p>
<p>Once the solution is cured, the negative PDMS mold is peeled off leaving behind the polymer nanowires. As the procedure sounds, it is a very lengthy and time consuming process. The article reports that the stability of the structures must be taken into consideration while fabricating nanoposts with high aspect ratio. Collapse of nanoposts due to their own weight, adhesion forces between adjacent nanoposts and the surface morphology needed to support the posts may cause problems, which can be solved by varying the length or the radius of the nanoposts with an appropriate selection of the supporting liquid metal.</p>
<p>In the track-etch method, a thin polycarbonate film was initially spin coated, irradiated with Ar<sup>9+</sup> ions at 220 MeV, and UV, followed by chemical etching to finally form pores of 15 and 100 nm with lengths ranging from a few nm to μm. Polypyrrole (ppy) doped with perchlorate electrolyte was used for the synthesis of the nanowires on the track etched membrane of a nanoporous polycarbonate template [<xref ref-type="bibr" rid="b34-sensors-11-05087">34</xref>,<xref ref-type="bibr" rid="b35-sensors-11-05087">35</xref>]. The synthesis was done using different conditions to control the growth of the polymer layer [<xref ref-type="bibr" rid="b35-sensors-11-05087">35</xref>]. The deposition conditions with which the polymer was completely filled the polycarbonate template up to the top was chosen as the best one, since the intention was to avoid any overgrowth of the material outside the template, as it may form like a film layer that would cause a problem during the time of immobilization of the antibody-antigen. This method of preparing polymer nanowires with certain parameters was shown to be the best method as per [<xref ref-type="bibr" rid="b36-sensors-11-05087">36</xref>], but it has been mentioned that it is an expensive and time consuming method which involves a very complex procedure.</p>
<p>The preparation of alumina templates plays a major role in the synthesis of nanowires. According to one report [<xref ref-type="bibr" rid="b31-sensors-11-05087">31</xref>], alumina templates having high thermal and electrical stability properties were prepared using an anodic oxidation process, It was mentioned that this 99.8% pure alumina membrane was prepared as a challenge to the previous issue that the alumina membranes had, whereby they displayed high pore density and uniform pore diameter, but were not able to react with water at temperatures over 80 °C without making holes through the pores and thus offering less resistance to attack by acids and alkali. They were then oxidized to form a very good porous membrane. The final membrane was ready after giving it a heat treatment and it was checked for its corrosion and chemical resistance.</p>
<p>The procedure for preparing the template was very lengthy and involved a lot of chemicals, even starting from the thermal oxidation of the alumina plate. Although this process is used even nowadays for preparing templates, it remains a very expensive and time consuming process, thus commercially available alumina templates are preferred as they have all the characteristics of the ones prepared in the lab.</p>
<p>Several methods were being used to synthesize ppy nanowires in the past, but the three electrode cell method is now widely used by many researchers due to the ease of growing nanowires and also because it is cheaper in comparison with other methods. The synthesis of ppy nanowires using a three electrode cell as reported in [<xref ref-type="bibr" rid="b16-sensors-11-05087">16</xref>,<xref ref-type="bibr" rid="b37-sensors-11-05087">37</xref>,<xref ref-type="bibr" rid="b38-sensors-11-05087">38</xref>] was done using an alumina template that is commercially available on the market. They used an alumina template of 200 nm diameter and 60 μm thickness (Whatmann International). A gold layer was initially sputtered onto the back side of the template which serves as a base to the nanowire that is going to be developed. The three electrode cell method for the electrodeposition of the nanowires employed the substrate as the working electrode, platinum mesh as the counter electrode and Ag/AgCl as the reference electrode using a potentio/galvanostat. They used a mixture of 0.5 M pyrrole and 0.2 M LiClO<sub>4</sub> as the electrolyte solution.</p>
<p>The whole electrodeposition process was done potentiostatically at 0.9 V for 30 min. After deposition, the gold seed layer was removed using 0.15 M KI in 0.1 M I<sub>2</sub> gold etchant solution and the alumina templates were dissolved using 3 M NaOH solution. The obtained nanowires were analyzed using a SEM instrument. <xref ref-type="fig" rid="f2-sensors-11-05087">Figure 2</xref> shows a SEM image of polypyrrole nanowires grown using the three electrode method. These nanowires were then suspended on the electrodes for aligning it into individual threads. This will make the system to be devised in a uniform manner and also effective for the subsequent immobilization of proteins.</p></sec>
<sec>
<label>2.2.</label>
<title>Alignment of Nanowires</title>
<p>Electrochemically synthesized nanowires will be distributed randomly all over the surface of the substrate. These nanowires are then made to align in a uniform fashion so that there is no interlinking between them because the nanowires interlinked one on top of the other would lead to a situation where the proteins cannot be immobilized on the nanowires that are present below. The surface of the layer will also be non-uniform all over the device, making protein binding impossible. This would be a barrier to improving the sensitivity of any device, so the nanowires are first aligned before binding the proteins. Several methods are used for aligning nanowires among which the dielectrophoresis technique has attracted a great deal of attention due the fact that each and every nanowire can be effectively aligned. The so called mechanical break junction method was one of the methods that was earlier used for aligning polymer nanowires.</p>
<p>This method works in a way that allows the material to be synthesized and aligned at the same time. The material to be polymerized (aniline, as a monomer) was first attached to a sharp tunneling microscope tip (STM) separated by an insulation layer to focus the growth of the nanowire. A mixture of 0.1 M aniline + 0.5 M Na<sub>2</sub>SO<sub>4</sub> was used for growing the nanowire. It was first electrodeposited on the tip of an insulator at ∼1 V (<italic>versus</italic> Ag/AgCl reference electrode) followed by applying a potential along the tip of the substrate where the polymer starts to grow as a thin wire. It was reported that an increase in current was observed when this wire hits the substrate as seen in <xref ref-type="fig" rid="f3-sensors-11-05087">Figure 3</xref>, and was further stretched to reduce the thickness using a dc motor [<xref ref-type="bibr" rid="b39-sensors-11-05087">39</xref>].</p>
<p>The conductance of the grown nanowire was observed using a graph plot [<xref ref-type="fig" rid="f3-sensors-11-05087">Figure 3(B)</xref>] and the stretching process was continued to improve the conductance of the nanowire. Although a polymer nanowire of calculated conductance can be obtained using this method, there are many drawbacks of using this method. One of these drawbacks is that only one nanowire can be grown at a time. Obviously it is desirable for fabrication processes to be faster to allow the production of multiple devices at a given particular time.</p>
<p>The dielectrophoresis method of aligning the nanowires was used at recent times since the alignment is easier and also because comparatively, a greater amount of nanowires can be aligned and tested at the same time. First, interdigitated electrodes were fabricated on a SiO<sub>2</sub> wafer using a photolithography process with chromium and gold. The polymer nanowires were then dispensed all over the electrodes in a random fashion. The presence of nanowires was verified by measuring the I-V characteristics of the electrodes, so a potential was applied across the ends of the electrodes and the current was measured with the use of a potentiostat. <xref ref-type="fig" rid="f4-sensors-11-05087">Figure 4</xref> clearly shows the amount of potential applied to the electrodes making the nanowires align with a small amount of current passing through them [<xref ref-type="bibr" rid="b44-sensors-11-05087">44</xref>]. The nanowires present in a 2 μL diluted suspension were dispensed on 16 pairs of well aligned interdigitated electrodes [<xref ref-type="bibr" rid="b40-sensors-11-05087">40</xref>]. A 1 V potential from peak to peak and 5 MHz frequency was applied to the electrodes allowing the nanowires to align along the corresponding electric charges of the material. This means that the nanowires are present in between the electrodes with their ends touching the electrodes [<xref ref-type="bibr" rid="b37-sensors-11-05087">37</xref>].</p>
<p>The electrodes act as a capacitor before the nanowires are suspended on them. The potential applied to the electrodes flows in the air medium making no electrical contact between the electrodes. These electrodes later act as a resistor after the suspension of the nanowires which makes the electrodes come in contact with each other. Usually, a probe station was used by most researchers for applying the voltage and measuring the current at the same point. After aligning the nanowires in the desired position, selective deposition of the metal was done using the three electrode cell method making an ohmic contact on the electrodes which was helpful in immobilizing the biomolecules in a easier way. The ohmic contact was also helpful in measuring the I-V characteristics. The output current depends on the number of nanowires present on the electrodes which shows that the amount of current flowing through the nanowires gets shared and the sensitivity of the sensor depends on the number of nanowires present. The next step involved in developing the biosensor is the immobilization of the biomolecules.</p></sec>
<sec>
<label>2.3.</label>
<title>Immobilization of Proteins</title>
<p>The immobilization of protein constitutes the sensing part of the sensor that captures the affected cells and transmits the output in the form of an electrical signal. In 1962, Clark and Lyons [<xref ref-type="bibr" rid="b40-sensors-11-05087">40</xref>] were the first to demonstrate a biosensor integration using an enzyme and an electrode together which had many advantages in building the sensor with high selectivity and ease of use in complex media. The immobilization was done using various methods in which the entrapment process involved fixing of proteins onto the nanowires at some constant voltage. It was later realized that the antibodies were just barely sticking onto the nanowires and were not firmly attached [<xref ref-type="bibr" rid="b41-sensors-11-05087">41</xref>,<xref ref-type="bibr" rid="b42-sensors-11-05087">42</xref>]. EDC crosslinking is a recent technique that involves covalent bonding between the proteins and the transducer. The immobilization in general, is said to be effective since the proteins firmly bind onto the nanowires at specific spots. The more activated sites on the nanowires and bonds to the captured proteins there are increases the sensitivity of the device.</p>
<p>The entrapment method of immobilizing biomolecules on the nanowire surface is well explained in [<xref ref-type="bibr" rid="b41-sensors-11-05087">41</xref>]. According to this report, nanowires of ∼320 nm diameter and ∼2 nm long were used for the binding of proteins. Protein modified nanowires were mostly used for binding. Biotin-FITC solution in a mixture with PBS (pH 7.4) was agitated constantly at 25 °C. This mixture was then entrapped onto the nanowires by incubating the protein modified nanowires with the biotin-FITC solution. The amount of biotins attached to the nanowires was determined by a signal generated at the output. Using this method, the biomolecules were just physically entrapped onto the nanowires, which does not result in much effectiveness during sensing as a strong attachment of proteins is needed for the sensing of the antigens.</p>
<p>In [<xref ref-type="bibr" rid="b43-sensors-11-05087">43</xref>] the EDC cross-linking technique was used, serving as the reaction layer in between the nanowire and the antibody bonding it together. A known quantity of protein was mixed with a buffer solution containing EDC and NHS, and centrifuged after agitation of the solution for 1.5 h. According to the authors the EDC/NHS will activate the carboxyl groups which are already present in the polymer nanowires, and later bond with the amine residues that are present at the ends of all the antibodies forming a strong covalent bond between the nanowires and proteins. The bonding could also be done in the reverse manner. <xref ref-type="fig" rid="f5-sensors-11-05087">Figure 5</xref> shows the reactions involved in the EDC cross-linking between the nanowires and the proteins. The mixing of the buffer solution with the nanowires can either be done in a centrifuge tube [<xref ref-type="bibr" rid="b43-sensors-11-05087">43</xref>] or also on the top of the lithographically fabricated electrodes. The presence of proteins on the nanowires was observed by the change of solution to a fluorescent color.</p></sec></sec>
<sec>
<label>3.</label>
<title>Electropolymerization of Carbon Nanotube Biosensor</title>
<p>The synthesis of carbon nanotube (CNT)-based biosensors using chemical vapor deposition is being followed at recent times due to unique properties of this material in biomedical applications [<xref ref-type="bibr" rid="b45-sensors-11-05087">45</xref>]. It is believed that the electrochemical reactivity of the CNTs can enhance the bio-molecule binding, and also that the electron transfer reactions of proteins can be well promoted [<xref ref-type="bibr" rid="b45-sensors-11-05087">45</xref>–<xref ref-type="bibr" rid="b48-sensors-11-05087">48</xref>]. In 1993, Iijima and Ichihashi [<xref ref-type="bibr" rid="b49-sensors-11-05087">49</xref>] and Bethune <italic>et al.</italic> [<xref ref-type="bibr" rid="b50-sensors-11-05087">50</xref>] were the first to synthesize single walled carbon nanotubes after the discovery of CNTs in 1991. CNTs are classified into single wall (SWNTs) and multi-wall nanotubes (MWNTs). SWNT is a cylindrical shaped structure on which a layer of graphite sheet is spread and makes it appear as a tube shape, whereas, MWNTs consist of multiple graphene sheets interspaced by 3.4 Å [<xref ref-type="bibr" rid="b51-sensors-11-05087">51</xref>,<xref ref-type="bibr" rid="b52-sensors-11-05087">52</xref>]. Synthesis of CNTs by arc discharge evaporation, laser ablation and chemical vapor deposition are reviewed in this paper. Electrochemical detection of CNTs has also been reported using the three electrode cell method, which is believed to be a very effective process that prepares the material in such a way that the immobilization of the proteins will be excellent in comparison with the material prepared using other processes. This may also lead to production of a multi-sensing biosensor.</p>
<sec>
<label>3.1.</label>
<title>Synthesis of CNTs</title>
<p>In 1991, a needle like tube structure was first reported by Iijima, which was later produced using an arc discharge evaporation technique [<xref ref-type="bibr" rid="b53-sensors-11-05087">53</xref>]. Later, the same technique was done by applying a direct current to the negative end of the carbon electrode to further grow the needle-like tube from 4 nm to 30 nm in diameter. The evaporation of carbon was done using an arc discharge chamber that had two vertical thin electrodes at the centre of the chamber filled with methane and argon gas. The lower chamber had a small dip at the lower electrode onto which the evaporation iron metal was placed and the arc discharge was applied. Argon, methane and iron were the three main constituents responsible for the synthesis of the SWNTs and MWNTs.</p>
<p>In 1996, Smalley and co-workers used the so-called laser ablation technique to grow SWNTs. It was developed by vaporizing graphite rods with small amounts of Ni and Co at 1,200 °C [<xref ref-type="bibr" rid="b54-sensors-11-05087">54</xref>]. The nanotube started to grow bigger in size after this treatment. The excess particles got detached from the surface leaving out sufficient amounts of carbon that can poison the catalysis and also allowing it to terminate with a fullerene-like tip or catalyst particles.</p>
<p>Although high yields (&gt;70%) of SWNTs can be obtained using these two techniques, there are some drawbacks which hinder the applications of CNTs in biosensors. These are: (a) high temperature is applied during evaporation of material onto the carbon atoms, and (b) the prepared nanotubes get tangled within the solution, making it difficult to deposit them effectively on a substrate.</p>
<p>Recently, chemical vapor deposition has become the preferred technique for the synthesis of CNTs because of the two main advantages that the nanotubes can be prepared at a lower temperature and also that the prepared catalyst can be deposited on the working samples. The chemical vapor deposition was done on platinum wafers to grow the SWNTs without extraction of the oxide layer from the substrate. A mixture of 20 mg Fe(NO<sub>3</sub>)·9H<sub>2</sub>O, 5 mg MoO<sub>2</sub>(acac) and 15 mg alumina added to 15 mL of methanol solution was prepared. The reagents were stirred for 24 h and sonicated for 1hour and then suspended on the PMMA substrate. The substrate was heated at 170 °C for 5 min after the solvent got evaporated at room temperature. Then the CVD process was done at 1,000 °C using methane to move out the CNTs. These nanotubes were arranged on the chip for electrochemical detection [<xref ref-type="bibr" rid="b59-sensors-11-05087">59</xref>], as shown in the <xref ref-type="fig" rid="f6-sensors-11-05087">Figure 6</xref>. The three electrode system was used for the detection of the nanotubes which was considered to be the most effective method that can make the CNTs highly sensitive. The setup also was used for selective binding of gold after the deposition of nanotubes. The three electrodes are the working electrode which is the CNT array, Pt wire as the counter electrode and Ag/AgCl as the reference electrode. A chamber with K<sub>3</sub>[Fe(CN)<sub>6</sub>] and amino acid as the electrolyte solution were arranged with the three electrode setup where the investigation of electrochemical characteristics of the device was successfully done.</p></sec>
<sec>
<label>3.2.</label>
<title>Alignment of Nanotubes</title>
<p>We have discussed so far different methods of synthesis of nanowires, and how these nanowires are then aligned to make good contacts during the time of immobilization of the proteins. The alignment of CNTs was done using various methods such as the flow cell method [<xref ref-type="bibr" rid="b55-sensors-11-05087">55</xref>], growth from catalyst patterns [<xref ref-type="bibr" rid="b56-sensors-11-05087">56</xref>] and electro-spinning [<xref ref-type="bibr" rid="b57-sensors-11-05087">57</xref>]. However, electric field assisted alignment of the nanotubes on metal electrodes is considered to be a good method since the nanotubes can be made to settle at a desired point of interest by applying an electric field. Electro-spinning and DC electric field and DC-AC electric field based methods for aligning the CNTs are reviewed in this paper.</p>
<p>Electro-spinning of SWNTs using the electrostatic method is one of the older techniques used for aligning them. Most researchers mix a polymer composite with CNTs for alignment and later remove it after the alignment of the structure is done. As per the report [<xref ref-type="bibr" rid="b57-sensors-11-05087">57</xref>], poly(vinylpyrrolidone) (PVP) was doped with SWNT because of the good compatibility of the polymer with the nanotubes. This mixture was considered to be more homogenous. A thin sheet of aluminum foil was used at either ends of the fibers to drive the charge of the substrate to ground. A single piece of SWNT-PVP composite fiber was electrospun, which aligned the fiber along the aluminum ends. The PVP was later removed by heating the fiber at 600 °C, leaving the SWNT aligned. The major disadvantage of this method is that the size of fibers that are aligned decreases after decomposition of the polymer composite from the SWNT, which will increase the local charge density of the nanotubes. Another simple method is mentioned in [<xref ref-type="bibr" rid="b58-sensors-11-05087">58</xref>] where they use micro or nanomanipulators to make an electric contact with the electrodes and move the nanotubes from one place to another for attachment. One end of the tweezer will be in contact with one of the nanotubes and the other end in contact with the other nanotube. When a voltage is applied across the nanotubes, they move closer to each other making a contact making a clamp between the tweezers.</p>
<p>DC field-assisted alignment of the nanotubes has been reported [<xref ref-type="bibr" rid="b59-sensors-11-05087">59</xref>] in which the nanotubes can be formed wherever needed. According to the report, they developed an electrode having finger-like structures using photolithography and a lift off process. The alignment was performed by suspending the freshly prepared CNTs on the top of the electrode and varying the voltage for different conditions. The authors modified the nanowire density by varying the amount of nanotubes being dispersed on the electrodes. This was done by varying the concentration of the solution containing the nanotubes. I-V characteristics were used for analyzing the amount of current passing through the electrodes, as shown in <xref ref-type="fig" rid="f6-sensors-11-05087">Figure 6(B)</xref>.</p>
<p>The characteristics of this process have been well analyzed and it was found that the dc electric fields increased due to the increase in density of the carbon nanotubes deposited on the electrodes. It was also observed that the ends of the carbon nanotubes came in contact with each other as they were rotating towards the applied field. This lead to combinations of many nanotubes, to become a single nanotube. It has also been reported that the nanotubes were mainly found to be present on the top of the electrodes in comparison to the nanotubes present in-between the electrodes. According to the authors, this might have occurred due to the non-uniform distribution of current to the electrodes. Liu <italic>et al.</italic> have proposed that the alignment of the nanotubes using an ac field [<xref ref-type="bibr" rid="b60-sensors-11-05087">60</xref>] depends on the length of the nanowires that are being aligned in correspondence with the electrode gap that it is aligned. Their experimental results prove that longer nanotubes get aligned faster than shorter nanotubes when they are dropped in a 2 μm gap electrode and the explanation they provide for this kind of behavior is that the dielectrophoretic force will be greater on the longer nanowires in comparison to the smaller ones.</p>
<p>Chung <italic>et al.</italic> have reported that by applying a combined ac and dc field [<xref ref-type="bibr" rid="b61-sensors-11-05087">61</xref>], nanotubes can be easily aligned and deposited along the electrodes leaving behind the unwanted particles. It has been emphasized that the nanotubes respond very slowly when a dc electric field is applied, whereas the unwanted particles present in the solution respond more quickly. A schematic diagram for applying both the ac and dc electric fields has been proposed [<xref ref-type="fig" rid="f7-sensors-11-05087">Figure 7(A)</xref>] which has a resistor of high value in series. This resistor allows the dc potential to flow across the large resistance. There is also a capacitor present in parallel to the resistor without which a large resistance would have been resulted due to low impedance of the electrode gap. Now three different kinds of tests were performed where initially a dc voltage was applied alone to the electrodes, and it was found that the waste particles also got attracted towards the electrodes and when a pure ac voltage was applied, many nanotubes aligned together by attaching themselves to the ends of other nanotubes. The SEM image in <xref ref-type="fig" rid="f7-sensors-11-05087">Figure 7(B)</xref> shows the individual nanotubes that were aligned along the electrodes due to the effect of both the ac and dc voltage being applied together. A similar kind of result is published in [<xref ref-type="bibr" rid="b62-sensors-11-05087">62</xref>], where the nanotubes are aligned using only ac, only dc and both ac and dc, but there the authors have attempted to align the nanotubes in an array fashion with single nanotubes between each gap on an electrode containing 100 such electrodes.</p></sec>
<sec>
<label>3.3.</label>
<title>Immobilization of Antibodies</title>
<p>Many conventional methods are available for immobilization of proteins onto nanotubes such as enzyme linked immune-absorbent assay (ELISA) and electrophoretic immunoassay. However, since these techniques use very costly equipments to build the biosensors, electrochemical impedance spectroscopy and covalent attachment [<xref ref-type="bibr" rid="b38-sensors-11-05087">38</xref>] of antibodies have been of much interest to effectively bind proteins. The binding of CNT using the ELISA process and covalent linking using EDC as cross-linker are reviewed. The main part of the biosensor is the attachment of the proteins to the nanowires which detects the affected cells and sends a signal as output. This part of the biosensor should be carefully devised. There are many techniques available for immobilization of the proteins onto the nanowires such as the one reported in [<xref ref-type="bibr" rid="b63-sensors-11-05087">63</xref>,<xref ref-type="bibr" rid="b64-sensors-11-05087">64</xref>] using three dimensional intra-molecular hydrogen bonds. A similar kind of method was followed by [<xref ref-type="bibr" rid="b65-sensors-11-05087">65</xref>,<xref ref-type="bibr" rid="b66-sensors-11-05087">66</xref>] in which immobilization of proteins was done by hydrogen bonding on the nanotube template by incubating both for several hours. Adsorption of antibody by non-covalent attachment onto the SWNT in a graphite disk electrode was reported by O’Connor <italic>et al.</italic> [<xref ref-type="bibr" rid="b67-sensors-11-05087">67</xref>]. Kam <italic>et al.</italic> [<xref ref-type="bibr" rid="b68-sensors-11-05087">68</xref>] also discussed the non-covalent attachment of biomolecules onto nanowires which they assumed to be successful by observing the enhanced attachment of poly-<sc>l</sc>-lysine (PLL) with the proteins in a hydrophobic surface of heat treated nanofibers.</p>
<p>The ELISA process is a complex one which consumes a lot of time just in cleaning the antibody or the proteins. It is considered to be ubiquitous in biomedical applications and clinical testing. There are two kinds of processes that can be done using the ELISA method: (a) the direct ELISA process that employs monoclonal antibodies to detect the presence of particular antigens in a sample and (b) the indirect ELISA process in which is used to determine the presence of a specific antibody in a specimen such as a serum. Huang <italic>et al</italic>. have reported the binding using a direct ELISA process [<xref ref-type="bibr" rid="b69-sensors-11-05087">69</xref>]. In this process initially the antibodies are treated with water, and washed several times so that the protein surface becomes activated to bind it on the nanowires. Then the antibodies are just dispersed on the top of the carbon nanotubes for 2 h at room temperature. Later bovine serum albumin which is a blocking agent is dispersed in between the gaps of the antibodies so that the testing of the system can be done easily. After three complete washings the antigen, namely <italic>Salmonella typhirium</italic>, was incubated onto the antibodies for 1 h for testing the device. Finally, the binding reaction was stopped by adding 2 M NaOH solution and the binding efficiency of the antigens to the antibodies were calculated. Although the process is similar to covalent linkage during the binding process, the washing of the antigens is an added burden in the ELISA process.</p>
<p>An electrochemical microelectrode containing platinum along with modified SWCNTs has been reported (<xref ref-type="fig" rid="f8-sensors-11-05087">Figure 8</xref>) [<xref ref-type="bibr" rid="b74-sensors-11-05087">74</xref>] for label free detection of analytes. Electrochemical signals at various concentrations were recorded using differential pulse voltammograms. An increase in current was noticed due to the increase in concentration of the T-PSA. After many trials, it was confirmed that the addition of T-PSA onto the antibody-attached SWCNTs lead to the increase in the current. A slight defect occurred in the monolayer due to the compact packaging of the antibody on the SWCNT surface that could cause a very high electron transfer rate along the electrolyte and the CNT.</p>
<p>The covalent bonding of antibodies provides very strong attachment to the nanotubes. There are many reports that have been discussed on the covalent bonding of proteins [<xref ref-type="bibr" rid="b70-sensors-11-05087">70</xref>–<xref ref-type="bibr" rid="b72-sensors-11-05087">72</xref>]. The assembled SWNTs were found laying on the electrodes ready to be immobilized. Functionalized FITC along with antibody were washed and incubated with the SWNT for several hours [<xref ref-type="bibr" rid="b73-sensors-11-05087">73</xref>]. The conjugation between them was realized by the appearance of fluorescent color in the solution bath. <xref ref-type="fig" rid="f9-sensors-11-05087">Figure 9</xref> shows the SEM images that were taken after the immobilization of the antibodies onto the carbon nanotubes. The nanotube with conjugated FITC shown in the same figure exhibits a fluorescent color due to the presence of FITC [<xref ref-type="bibr" rid="b74-sensors-11-05087">74</xref>].</p>
<p>It is reported that the SWNT-immobilized protein detection is a very promising and straightforward method for use as a biosensor. Many research groups have successfully demonstrated the working of immobilized SWNT biosensor [<xref ref-type="bibr" rid="b75-sensors-11-05087">75</xref>–<xref ref-type="bibr" rid="b77-sensors-11-05087">77</xref>]. This kind of covalent linking using EDC is also reported in the biotin streptavidin binding [<xref ref-type="bibr" rid="b78-sensors-11-05087">78</xref>–<xref ref-type="bibr" rid="b80-sensors-11-05087">80</xref>]. The authors also reported that the amino group of the protein linking with the carboxyl group of the nanotubes showed a greater response than the biosensor without MWNTs. According to this, the electrochemical reaction in the MWNT-COOH would be well enhanced and would behave as a good promoter.</p></sec></sec>
<sec>
<label>4.</label>
<title>Electropolymerization of ZnO Biosensors</title>
<p>Zinc oxide is also a promising material that can be used in advanced sensor technologies due to its unique physical and chemical properties. ZnO nanorods were immobilized with protein for biosensor applications only using the FET concept. Very recently, electropolymerized ZnO nanorods for real time bio-sensing have been proposed for the first time by Liu <italic>et al.</italic> [<xref ref-type="bibr" rid="b81-sensors-11-05087">81</xref>], and may be developed as biosensors for protein detection in the future. ZnO nanorods were mainly used for building solar cells [<xref ref-type="bibr" rid="b82-sensors-11-05087">82</xref>–<xref ref-type="bibr" rid="b84-sensors-11-05087">84</xref>], gas sensors [<xref ref-type="bibr" rid="b85-sensors-11-05087">85</xref>], LEDs [<xref ref-type="bibr" rid="b86-sensors-11-05087">86</xref>] and piezo-electric devices [<xref ref-type="bibr" rid="b87-sensors-11-05087">87</xref>–<xref ref-type="bibr" rid="b89-sensors-11-05087">89</xref>]. Although the synthesis of ZnO nanorods was done using various methods [<xref ref-type="bibr" rid="b90-sensors-11-05087">90</xref>–<xref ref-type="bibr" rid="b92-sensors-11-05087">92</xref>], they all require very expensive equipment. ZnO nanorods were also be synthesized using cheaper methods such as chemical bath and spray pyrolysis [<xref ref-type="bibr" rid="b93-sensors-11-05087">93</xref>,<xref ref-type="bibr" rid="b94-sensors-11-05087">94</xref>], but electrodeposition using the three electrode method in an AAO template is the easiest and cheapest method in comparison. The immobilization of biomolecules can also be achieved using this material.</p>
<sec>
<label>4.1.</label>
<title>Synthesis of ZnO Nanorods</title>
<p>Synthesis of ZnO nanorods was first reported in 1996 by Peulon <italic>et al.</italic> [<xref ref-type="bibr" rid="b95-sensors-11-05087">95</xref>] who developed based on an electrodeposition method. They had observed that the oxidation needs an oxygen atom and the zinc metal cannot be deposited as it is onto the substrate. They performed the electrodeposition of ZnO nanorods using ZnCl<sub>2</sub> solution with a KCl electrolyte on a glass substrate at the rate of 0.1–1 μm/h. Preparation of ZnO nanorods have also been reported by a method [<xref ref-type="bibr" rid="b96-sensors-11-05087">96</xref>] in which the oxidation by spray pyrolysis was done using a mixture of triethanolamine and Zn (CH<sub>3</sub>COO)<sub>2</sub>·2H<sub>2</sub>O, and were ground with NaOH for half an hour. The so-called ZnO nanorods were then obtained by drying this chemical combination at 80 °C for 2 h. Preparation of ZnO nanorods has also been done using a quasi-spherical method in which Zn(CH<sub>3</sub>COO)<sub>2</sub>·2H<sub>2</sub>O was stirred with methanol at 60 °C to which drops of methanol were later added, and then dried for 24 h. These types of preparation of ZnO nanorods cannot be used for the development of flexible biosensors due to the high temperatures required for the fabrication of nanorods.</p>
<p>The fabrication of ZnO nanorods at lower temperatures using aqueous solutions is also currently being done by a lot of researchers. Kumar <italic>et al.</italic> has proposed the growth of ZnO nanorods at a lower temperature of 95 °C [<xref ref-type="bibr" rid="b97-sensors-11-05087">97</xref>] using zinc nitrate, Zn(NO<sub>3</sub>)·xH<sub>2</sub>O and hexamethylenetetramine for 10 h. These nanorods are actually grown on a silicon substrate having a seed layer that was coated using an ALD growth method. It is mentioned that irrespective of the seed layer charge, the nanorods will grow in an aligned manner depending on the distribution of the layer. The <xref ref-type="fig" rid="f10-sensors-11-05087">Figure 10</xref> shows the SEM image of the ZnO nanorods that were grown on the silicon substrate containing the seed layer. It is also said that the ZnO nanorods will grow in an aligned manner on a sapphire surface rather than on the silicon substrate. Lee <italic>et al.</italic> has proven this by growing well aligned ZnO nanorods on a sapphire substrate using periodic polar inverted templates [<xref ref-type="bibr" rid="b98-sensors-11-05087">98</xref>]. It is reported that nanorods grow well on the sapphire layer rather without any seed layer, but better growth has been reported on the silicon substrate containing the ZnO seed layer in comparison to that grown on a sapphire substrate. These kinds of aligned and patterned ZnO nanorods can also be grown using printing methods at a low temperature [<xref ref-type="bibr" rid="b99-sensors-11-05087">99</xref>]. The nanorods grown at different heights by increasing the time period is an expected result, but it was found that the diameter of the nanorods even varied depending on the temperature at which it was grown. It is confirmed that the diameter of the nanorods increased as the solution temperature was decreased. It is also said that the diameter of the nanorods varies depending on the concentration of zinc nitrate and HMTA. This process as can be seen is very time consuming and also the sizes of the nanowires grown are very short.</p>
<p>Preparation of ZnO nanorods using a three electrode cell was reported by Peulon <italic>et al.</italic> [<xref ref-type="bibr" rid="b100-sensors-11-05087">100</xref>]. According to the report, analysis of the mechanism of ZnO growth was done with aqueous zinc chloride solution using an electrodeposition method [<xref ref-type="bibr" rid="b101-sensors-11-05087">101</xref>] which was a turnaround for the researchers who were working with ZnO nanorods. Electrodeposition of nanorods has been widely preferred since as mentioned for the polymer nanowires, it is an easy and cheaper fabrication method. It was shown that the use of potassium chloride (KCl) as an electrolyte solution caused a strong adsorption by the presence of anions (Cl-) that acted as a capping agent [<xref ref-type="bibr" rid="b101-sensors-11-05087">101</xref>]. The electrodeposition was done using a three electrode arrangement containing a glass substrate as the working electrode, Pt wire as the counter electrode and saturated calomel electrode (SCE) as the reference electrode with KCl acting as an electrolyte solution. The process was done in two series in which the first series involved electrodeposition using different concentrations of 100 mL KCl electrolyte solution at 2 °C/cm<sup>2</sup> charge density. In the second series, 3.4 M KCl solutions were used by varying the values of the charge density. The surface morphology was analyzed by taking scanning electron microscopy (SEM) images</p>
<p>ZnO nanorods for bio-sensing applications have been reported in [<xref ref-type="bibr" rid="b81-sensors-11-05087">81</xref>], who were the first to attempt this. Synthesis of ZnO nanorods was done using a vapor solid process in which the furnace was attached to an alumina tube and a rotary pump. A polycrystalline Al<sub>2</sub>O<sub>3</sub> boat and the purchased ZnO powder were placed inside the alumina tube which was later introduced to the furnace chamber. ZnO nanorods on polycrystalline Al<sub>2</sub>O<sub>3</sub> was formed at a temperature of 1,400 °C with argon gas inside the chamber for 2 h. The process was repeated for different time periods to observe the effective growth of the nanowires. <xref ref-type="fig" rid="f11-sensors-11-05087">Figure 11(a–f)</xref> shows the SEM images of zinc oxide nanowires that were taken after the growth for different time periods. They developed a label free detection system in which amperometric sensing of analytes were done [<xref ref-type="bibr" rid="b102-sensors-11-05087">102</xref>]. The main advantage of this report is the attachment of analytes to the nanorods, but it is a more time consuming process than the method explained above.</p></sec>
<sec>
<label>4.2.</label>
<title>Alignment of Nanorods and Immobilization of Proteins</title>
<p>The synthesized nanorods were made to align along the electrodes as done for the other two materials. For the alignment of the ZnO nanorods, gold electrodes were prepared using a lift off process. The nanorods were then transferred to the Au patterned substrate using micro positioning and focused ion beam technology. They were arranged in such a way that the nanorods are in contact with the Au electrodes. Although no exact process was followed for aligning the nanorods, a micro-positioner tip of 200 nm diameter was used to separate the nanowires from each other. An ohmic contact was produced by selectively depositing a metal layer over the Au electrodes through which electric charges were applied. In the same report a similar process using a silicon substrate was also demonstrated. The analytes were integrated by injecting them with the use of a syringe and then analyzing the output. The next step after the alignment of the nanorods is the immobilization of the proteins to use as a biosensor.</p>
<p>The immobilization of proteins onto ZnO nanorods can be effectively done by covalent attachment using either a single or a double cross-linker. For attachment via a single cross-linking layer [<xref ref-type="bibr" rid="b103-sensors-11-05087">103</xref>], first the nanorods were immersed into a solution mixture containing ethanol with 3-(trimethoxysilyl)propyl aldehyde dissolved in water and acetic acid. The substrate containing the nanorods was treated with N<sub>2</sub> gas three times at 120 °C. The antibody was activated using amine functional groups. Then the aldehyde layer present in the nanorods was made to react with the amine group-functionalized antibodies forming a very strong covalent attachment. The antibody attachment was analyzed by attaching FITC to the antibody and inspected using a fluorescence microscope. <xref ref-type="fig" rid="f12-sensors-11-05087">Figure 12(A,B)</xref> below show the microscopic image of nanowires with biotin and fluorescent microscopic image of nanowires with biotin, respectively. As an improvement to this method, Hunt <italic>et al.</italic> have done the covalent attachment of the antibodies using a double-linking layer [<xref ref-type="bibr" rid="b104-sensors-11-05087">104</xref>]. Two samples containing the ZnO nanorods were treated with ethanol to clean the surface followed by addition of (3-glycidyloxy-propyl)trimethoxysilane (GPS) to one of the samples. The other sample was treated initially with (3-mercaptopropyl)trimethoxysilane (MTS) followed by treatment with <italic>N</italic>-γ-maleimidobutyryloxy-succinimide ester (GMBS) which is the second covalent linker. Finally, the antibodies were attached to both the samples which had a uniform distribution all over the surface. The activation of the layer using the cross linkers were confirmed by taking AFM images as shown in <xref ref-type="fig" rid="f12-sensors-11-05087">Figure 12(C,D)</xref>. It is said that the fluorescence content on the GPS was comparatively less than the florescence present on the sample containing MTS, which proves that the antibody immobilization can be improved by using MTS rather than GPS.</p></sec></sec>
<sec sec-type="conclusions">
<label>5.</label>
<title>Conclusions and Future Directions</title>
<p>In this paper we have reviewed different methods for the synthesis, alignment and immobilization of proteins on nanowires, nanotubes and nanorods. All three materials reviewed in this paper are widely used in the bio-sensing application field due to their promising applications. The usage of all the three materials is relatively new to this field and research using zinc oxide nanorods has only just started recently. In the future, a stable process for the identification of immobilization has to be developed. The identification using fluorescent techniques does not sound reasonable. Also the immobilization of antibodies on specific sites can be concentrated which will improve the sensitivity of the devices more. The biosensor as a whole is still facing a major challenge of implantation of the device on human as a real time device which has environmental and health issues. A lot of effort is under way to develop a device in such a way that the biosensors can be used for real time detections.</p></sec></body>
<back>
<ref-list>
<title>Reference</title>
<ref id="b1-sensors-11-05087"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yogeswaran</surname><given-names>U</given-names></name><name><surname>Chen</surname><given-names>S</given-names></name></person-group><article-title>A review on the electrochemical sensors and biosensors composed of nanowires as sensing material</article-title><source>Sensors</source><year>2008</year><volume>8</volume><fpage>290</fpage><lpage>313</lpage><pub-id pub-id-type="doi">10.3390/s8010290</pub-id></citation></ref>
<ref id="b2-sensors-11-05087"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhao</surname><given-names>Z</given-names></name><name><surname>Lei</surname><given-names>W</given-names></name><name><surname>Zhang</surname><given-names>X</given-names></name><name><surname>Wang</surname><given-names>B</given-names></name><name><surname>Jiang</surname><given-names>H</given-names></name></person-group><article-title>ZnO-based amperometric enzyme biosensors</article-title><source>Sensors</source><year>2010</year><volume>10</volume><fpage>1216</fpage><lpage>1231</lpage><pub-id pub-id-type="doi">10.3390/s100201216</pub-id><pub-id pub-id-type="pmid">22205864</pub-id></citation></ref>
<ref id="b3-sensors-11-05087"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wanekaya</surname><given-names>A</given-names></name><name><surname>Chen</surname><given-names>W</given-names></name><name><surname>Myung</surname><given-names>N</given-names></name><name><surname>Mulchandani</surname><given-names>A</given-names></name></person-group><article-title>Nanowire based electrochemical biosensor</article-title><source>Electroanalysis</source><year>2006</year><volume>18</volume><fpage>533</fpage><lpage>550</lpage><pub-id pub-id-type="doi">10.1002/elan.200503449</pub-id></citation></ref>
<ref id="b4-sensors-11-05087"><label>4.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Alivisatos</surname><given-names>P</given-names></name></person-group><article-title>The use of nanocrystals in biological detection</article-title><source>Nat. Biotechnol</source><year>2004</year><volume>22</volume><fpage>47</fpage><lpage>52</lpage><pub-id pub-id-type="doi">10.1038/nbt927</pub-id><pub-id pub-id-type="pmid">14704706</pub-id></citation></ref>
<ref id="b5-sensors-11-05087"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kong</surname><given-names>J</given-names></name><name><surname>Franklin</surname><given-names>N</given-names></name><name><surname>Zhou</surname><given-names>C</given-names></name><name><surname>Chapline</surname><given-names>M</given-names></name><name><surname>Peng</surname><given-names>S</given-names></name><name><surname>Cho</surname><given-names>K</given-names></name><name><surname>Dai</surname><given-names>H</given-names></name></person-group><article-title>Nanotube molecular wires as chemical sensors</article-title><source>Science</source><year>2000</year><volume>287</volume><fpage>622</fpage><lpage>625</lpage><pub-id pub-id-type="doi">10.1126/science.287.5453.622</pub-id><pub-id pub-id-type="pmid">10649989</pub-id></citation></ref>
<ref id="b6-sensors-11-05087"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kong</surname><given-names>J</given-names></name><name><surname>Dai</surname><given-names>H</given-names></name></person-group><article-title>Full and modulated chemical grating of individual carbon nanotubes by organic amine compounds</article-title><source>J. Phys. Chem</source><year>2001</year><volume>105</volume><fpage>2890</fpage><lpage>2893</lpage><pub-id pub-id-type="doi">10.1021/jp0037910</pub-id></citation></ref>
<ref id="b7-sensors-11-05087"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cui</surname><given-names>Y</given-names></name><name><surname>Wei</surname><given-names>Q</given-names></name><name><surname>Park</surname><given-names>H</given-names></name><name><surname>Lieber</surname><given-names>CM</given-names></name></person-group><article-title>Nanowire nanosensors for highly sensitive and Selective detection of biological and chemical species</article-title><source>Science</source><year>2001</year><volume>293</volume><fpage>1289</fpage><lpage>1292</lpage><pub-id pub-id-type="doi">10.1126/science.1062711</pub-id><pub-id pub-id-type="pmid">11509722</pub-id></citation></ref>
<ref id="b8-sensors-11-05087"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Besteman</surname><given-names>K</given-names></name><name><surname>Lee</surname><given-names>J</given-names></name><name><surname>Wietz</surname><given-names>F</given-names></name><name><surname>Heering</surname><given-names>H</given-names></name><name><surname>Dekker</surname><given-names>C</given-names></name></person-group><article-title>Enzyme coated carbon nanotubes as single-molecule biosensors</article-title><source>Nano Lett</source><year>2003</year><volume>3</volume><fpage>727</fpage><lpage>730</lpage><pub-id pub-id-type="doi">10.1021/nl034139u</pub-id></citation></ref>
<ref id="b9-sensors-11-05087"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname><given-names>R</given-names></name><name><surname>Bangsaruntip</surname><given-names>S</given-names></name><name><surname>Drouvalakis</surname><given-names>KA</given-names></name><name><surname>Kam</surname><given-names>NWS</given-names></name><name><surname>Shim</surname><given-names>M</given-names></name><name><surname>Kim</surname><given-names>Y</given-names></name><name><surname>Li</surname><given-names>W</given-names></name><name><surname>Utz</surname><given-names>PJ</given-names></name><name><surname>Dai</surname><given-names>H</given-names></name></person-group><article-title>Noncovalent functionalization of carbon nanotubes for highly specific electronic biosensors</article-title><source>Proc. Natl. Acad. Sci. USA</source><year>2003</year><volume>100</volume><fpage>4984</fpage><lpage>4989</lpage><pub-id pub-id-type="doi">10.1073/pnas.0837064100</pub-id><pub-id pub-id-type="pmid">12697899</pub-id></citation></ref>
<ref id="b10-sensors-11-05087"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hahm</surname><given-names>J</given-names></name><name><surname>Lieber</surname><given-names>CM</given-names></name></person-group><article-title>Direct ultrasensitive electrical detection of DNA and DNA sequence variations using nanowires nanosensors</article-title><source>Nano Lett</source><year>2004</year><volume>4</volume><fpage>51</fpage><lpage>54</lpage><pub-id pub-id-type="doi">10.1021/nl034853b</pub-id></citation></ref>
<ref id="b11-sensors-11-05087"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname><given-names>Z</given-names></name><name><surname>Chen</surname><given-names>Y</given-names></name><name><surname>Li</surname><given-names>X</given-names></name><name><surname>Kamins</surname><given-names>TI</given-names></name><name><surname>Nauka</surname><given-names>K</given-names></name><name><surname>Williams</surname><given-names>RS</given-names></name></person-group><article-title>Sequence specific label free DNA sensors based on silicon nanowires</article-title><source>Nano Lett</source><year>2004</year><volume>4</volume><fpage>245</fpage><lpage>247</lpage><pub-id pub-id-type="doi">10.1021/nl034958e</pub-id></citation></ref>
<ref id="b12-sensors-11-05087"><label>12.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Malinauskas</surname><given-names>A</given-names></name><name><surname>Malinauskien</surname><given-names>J</given-names></name><name><surname>Ramanavicius</surname><given-names>A</given-names></name></person-group><article-title>Conducting polymer-based nanostructurized materials: Electrochemical aspects</article-title><source>Nanotechnology</source><year>2005</year><volume>16</volume><fpage>R51</fpage><pub-id pub-id-type="doi">10.1088/0957-4484/16/10/R01</pub-id><pub-id pub-id-type="pmid">20817958</pub-id></citation></ref>
<ref id="b13-sensors-11-05087"><label>13.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Heath</surname><given-names>JR</given-names></name></person-group><article-title>The chemistry of size and order on a nanometer scale</article-title><source>Science</source><year>1995</year><volume>270</volume><fpage>1315</fpage><lpage>1316</lpage><pub-id pub-id-type="doi">10.1126/science.270.5240.1315</pub-id></citation></ref>
<ref id="b14-sensors-11-05087"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Alivisatos</surname><given-names>AP</given-names></name></person-group><article-title>Semiconductor clusters, nanocrystals, and quantum dots</article-title><source>Science</source><year>1996</year><volume>271</volume><fpage>933</fpage><lpage>937</lpage><pub-id pub-id-type="doi">10.1126/science.271.5251.933</pub-id></citation></ref>
<ref id="b15-sensors-11-05087"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Andres</surname><given-names>RP</given-names></name><name><surname>Bielefeld</surname><given-names>JD</given-names></name><name><surname>henderson</surname><given-names>JI</given-names></name><name><surname>Janes</surname><given-names>DB</given-names></name><name><surname>Kolagunta</surname><given-names>VR</given-names></name><name><surname>Kubiak</surname><given-names>CP</given-names></name><name><surname>Mahoney</surname><given-names>WJ</given-names></name><name><surname>Osifchin</surname><given-names>RG</given-names></name></person-group><article-title>Self assembly of a two dimensional super lattice of molecularly linked metal structures</article-title><source>IBID</source><year>1996</year><volume>273</volume><fpage>1690</fpage><lpage>1963</lpage></citation></ref>
<ref id="b16-sensors-11-05087"><label>16.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mala Ekanayake</surname><given-names>EMI</given-names></name><name><surname>Preethichandra</surname><given-names>DMG</given-names></name><name><surname>Kaneto</surname><given-names>K</given-names></name></person-group><article-title>Polypyrrole nanotube array sensor for enhanced adsorption of glucose oxidase in glucose biosensors</article-title><source>Biosens. Bioelectron</source><year>2007</year><volume>23</volume><fpage>107</fpage><lpage>113</lpage><pub-id pub-id-type="doi">10.1016/j.bios.2007.03.022</pub-id><pub-id pub-id-type="pmid">17475472</pub-id></citation></ref>
<ref id="b17-sensors-11-05087"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname><given-names>CM</given-names></name><name><surname>Sun</surname><given-names>CQ</given-names></name><name><surname>Chen</surname><given-names>W</given-names></name><name><surname>Pan</surname><given-names>L</given-names></name></person-group><article-title>Electrochemical thin film deposition of polypyrrole on different substrates</article-title><source>Surf. Coating. Technol</source><year>2005</year><volume>198</volume><fpage>474</fpage><lpage>477</lpage><pub-id pub-id-type="doi">10.1016/j.surfcoat.2004.10.065</pub-id></citation></ref>
<ref id="b18-sensors-11-05087"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Malhotra</surname><given-names>BD</given-names></name><name><surname>Chaubey</surname><given-names>A</given-names></name><name><surname>Singh</surname><given-names>SP</given-names></name></person-group><article-title>Prospects of conducting polymers in biosensors</article-title><source>Anal. Chim. Acta</source><year>2006</year><volume>578</volume><fpage>59</fpage><lpage>74</lpage><pub-id pub-id-type="doi">10.1016/j.aca.2006.04.055</pub-id><pub-id pub-id-type="pmid">17723695</pub-id></citation></ref>
<ref id="b19-sensors-11-05087"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Rajesh</surname><given-names>V</given-names></name><name><surname>Takashima</surname><given-names>W</given-names></name><name><surname>Kaneto</surname><given-names>K</given-names></name></person-group><article-title>Amperometric tyrosinase based biosensor using an electropolymerized PTS-doped polypyrrole film as an entrapment support</article-title><source>Reactive Funct. Polym</source><year>2004</year><volume>59</volume><fpage>163</fpage><lpage>169</lpage><pub-id pub-id-type="doi">10.1016/j.reactfunctpolym.2004.01.006</pub-id></citation></ref>
<ref id="b20-sensors-11-05087"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yamato</surname><given-names>K</given-names></name><name><surname>Kaneto</surname><given-names>K</given-names></name></person-group><article-title>Tubular linear actuators using conducting polymer, polypyrrole</article-title><source>Anal. Chim. Acta</source><year>2006</year><volume>568</volume><fpage>133</fpage><lpage>137</lpage><pub-id pub-id-type="doi">10.1016/j.aca.2005.12.030</pub-id><pub-id pub-id-type="pmid">17761253</pub-id></citation></ref>
<ref id="b21-sensors-11-05087"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>So</surname><given-names>DS</given-names></name><name><surname>Kang</surname><given-names>I</given-names></name><name><surname>Huh</surname><given-names>H</given-names></name><name><surname>Lee</surname><given-names>H</given-names></name></person-group><article-title>Electrical impedance properties of carbon nanotube composite electrodes for chemical and biosensor</article-title><source>J. Nanosci. Nanotechnol</source><year>2010</year><volume>10</volume><fpage>3449</fpage><lpage>3452</lpage><pub-id pub-id-type="doi">10.1166/jnn.2010.2338</pub-id><pub-id pub-id-type="pmid">20358976</pub-id></citation></ref>
<ref id="b22-sensors-11-05087"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cai</surname><given-names>H</given-names></name><name><surname>Cao</surname><given-names>X</given-names></name><name><surname>Jiang</surname><given-names>Y</given-names></name><name><surname>He</surname><given-names>P</given-names></name><name><surname>Fang</surname><given-names>Y</given-names></name></person-group><article-title>Carbon nanotube enhanced electrochemical DNA biosensor for DNA hybridization detection</article-title><source>Anal. Bioanal. Chem</source><year>2003</year><volume>375</volume><fpage>287</fpage><lpage>293</lpage><pub-id pub-id-type="pmid">12560975</pub-id></citation></ref>
<ref id="b23-sensors-11-05087"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kiessling</surname><given-names>M</given-names></name><name><surname>Speidel</surname><given-names>J</given-names></name></person-group><article-title>Mutual information of MIMO channels in correlated Rayleigh environments-A general solution</article-title><source>Proc. IEEE</source><year>2004</year><volume>2</volume><fpage>814</fpage><lpage>818</lpage></citation></ref>
<ref id="b24-sensors-11-05087"><label>24.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname><given-names>Z</given-names></name><name><surname>Chen</surname><given-names>Y</given-names></name><name><surname>Li</surname><given-names>X</given-names></name></person-group><article-title>Sequence specific label free DNA sensors based on silicon nanowires</article-title><source>Nano Lett</source><year>2004</year><volume>4</volume><fpage>245</fpage><lpage>247</lpage><pub-id pub-id-type="doi">10.1021/nl034958e</pub-id></citation></ref>
<ref id="b25-sensors-11-05087"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gao</surname><given-names>ZQ</given-names></name><name><surname>Agarwal</surname><given-names>A</given-names></name><name><surname>Trigg</surname><given-names>AD</given-names></name></person-group><article-title>Silicon nanowire arrays for label free detection of DNA</article-title><source>Anal. Chem</source><year>2007</year><volume>79</volume><fpage>3291</fpage><lpage>3297</lpage><pub-id pub-id-type="doi">10.1021/ac061808q</pub-id><pub-id pub-id-type="pmid">17407259</pub-id></citation></ref>
<ref id="b26-sensors-11-05087"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kumar</surname><given-names>SA</given-names></name><name><surname>Chen</surname><given-names>S</given-names></name></person-group><article-title>Nanostructured zinc oxide particles in chemically modified electrodes for biosensor applications</article-title><source>Anal. Lett</source><year>2008</year><volume>41</volume><fpage>141</fpage><lpage>158</lpage><pub-id pub-id-type="doi">10.1080/00032710701792612</pub-id></citation></ref>
<ref id="b27-sensors-11-05087"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Angeli</surname><given-names>A</given-names></name><name><surname>Alessandri</surname><given-names>L</given-names></name></person-group><article-title>The electrochemistry of conducting polymers</article-title><source>Gazz. Chim. Ital</source><year>1916</year><volume>46</volume><fpage>279</fpage><lpage>285</lpage></citation></ref>
<ref id="b28-sensors-11-05087"><label>28.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bartlett</surname><given-names>PN</given-names></name><name><surname>Cooper</surname><given-names>JM</given-names></name></person-group><article-title>Unenhanced surface raman spectra of self assembled molecules adsorbed on a Au(111) surface</article-title><source>J. Electron Spectros. Relat. Phenom</source><year>1993</year><volume>1</volume><fpage>363</fpage><lpage>370</lpage></citation></ref>
<ref id="b29-sensors-11-05087"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Diaz</surname><given-names>AF</given-names></name><name><surname>Kanazawa</surname><given-names>KK</given-names></name><name><surname>Gardini</surname><given-names>GP</given-names></name></person-group><article-title>Electrochemical polymerization of pyrrole</article-title><source>J. Chem. Soc. Chem. Commun</source><year>1979</year><volume>14</volume><fpage>635</fpage><lpage>636</lpage></citation></ref>
<ref id="b30-sensors-11-05087"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wei</surname><given-names>Y</given-names></name><name><surname>Tian</surname><given-names>J</given-names></name><name><surname>Yang</surname><given-names>D</given-names></name><name><surname>Chemie</surname><given-names>DM</given-names></name></person-group><article-title>A new method for polymerization of pyrrole and derivatives</article-title><source>Rapid Commun</source><year>1991</year><volume>12</volume><fpage>617</fpage><lpage>623</lpage><pub-id pub-id-type="doi">10.1002/marc.1991.030121103</pub-id></citation></ref>
<ref id="b31-sensors-11-05087"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname><given-names>C</given-names></name><name><surname>Kang</surname><given-names>H</given-names></name><name><surname>Chang</surname><given-names>Y</given-names></name><name><surname>Hahm</surname><given-names>Y</given-names></name></person-group><article-title>Thermotreatment and chemical resistance of porous alumina membrane prepared by anodic oxidation</article-title><source>Kor. J. Chem. Eng</source><year>2000</year><volume>17</volume><fpage>266</fpage><lpage>272</lpage><pub-id pub-id-type="doi">10.1007/BF02699038</pub-id></citation></ref>
<ref id="b32-sensors-11-05087"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tolani</surname><given-names>SB</given-names></name><name><surname>Craig</surname><given-names>M</given-names></name><name><surname>DeLong</surname><given-names>RK</given-names></name><name><surname>Ghosh</surname><given-names>K</given-names></name><name><surname>Wanekaya</surname><given-names>AK</given-names></name></person-group><article-title>Towards biosensors based on conducting polymer nanowires</article-title><source>Anal. Bioanal. Chem</source><year>2009</year><volume>393</volume><fpage>1225</fpage><lpage>1231</lpage><pub-id pub-id-type="doi">10.1007/s00216-008-2556-0</pub-id><pub-id pub-id-type="pmid">19115054</pub-id></citation></ref>
<ref id="b33-sensors-11-05087"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pokroy</surname><given-names>B</given-names></name><name><surname>Epstein</surname><given-names>AK</given-names></name><name><surname>Persson-Gulda</surname><given-names>MC</given-names></name><name><surname>Aizenberg</surname><given-names>J</given-names></name></person-group><article-title>Fabrication of bioinspired actuated nanostructures with arbitrary geometry and stiffness</article-title><source>Adv. Mater</source><year>2009</year><volume>21</volume><fpage>463</fpage><lpage>469</lpage><pub-id pub-id-type="doi">10.1002/adma.200801432</pub-id></citation></ref>
<ref id="b34-sensors-11-05087"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Demoustier-Champagne</surname><given-names>S</given-names></name><name><surname>Legras</surname><given-names>R</given-names></name></person-group><article-title>Electrosynthesis of polypyrolle nanotubes using particle track-etched membranes as template</article-title><source>J. Phys. Chem. Chem. Phys. Bio</source><year>1998</year><volume>95</volume><fpage>1200</fpage><lpage>1203</lpage></citation></ref>
<ref id="b35-sensors-11-05087"><label>35.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Demoustier-Champagne</surname><given-names>S</given-names></name><name><surname>Ferain</surname><given-names>E</given-names></name><name><surname>Jerome</surname><given-names>C</given-names></name><name><surname>Erome</surname><given-names>R</given-names></name><name><surname>Legras</surname><given-names>R</given-names></name></person-group><article-title>Electrochemically synthesized polypyrrole nanotubules: Effects of different experimental conditions</article-title><source>Eur. Polym. J</source><year>1998</year><volume>34</volume><fpage>1767</fpage><lpage>1774</lpage><pub-id pub-id-type="doi">10.1016/S0014-3057(98)00034-2</pub-id></citation></ref>
<ref id="b36-sensors-11-05087"><label>36.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Malinauskas</surname><given-names>A</given-names></name><name><surname>Malinauskien</surname><given-names>J</given-names></name><name><surname>Ramanavicius</surname><given-names>A</given-names></name></person-group><article-title>Conducting polymer based nanostructurized materials: Electrochemical aspects</article-title><source>Nanotechnology</source><year>2005</year><volume>16</volume><fpage>R51</fpage><pub-id pub-id-type="doi">10.1088/0957-4484/16/10/R01</pub-id><pub-id pub-id-type="pmid">20817958</pub-id></citation></ref>
<ref id="b37-sensors-11-05087"><label>37.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cristina</surname><given-names>G</given-names></name><name><surname>Mangesh</surname><given-names>BA</given-names></name><name><surname>Baldrich</surname><given-names>E</given-names></name><name><surname>Javier</surname><given-names>MF</given-names></name><name><surname>Mulchandani</surname><given-names>A</given-names></name></person-group><article-title>Conducting polymer nanowire-based chemiresistive biosensor for the detection of bacterial spores</article-title><source>Biosens. Bioelectr</source><year>2010</year><volume>25</volume><fpage>2309</fpage><lpage>2312</lpage><pub-id pub-id-type="doi">10.1016/j.bios.2010.03.021</pub-id></citation></ref>
<ref id="b38-sensors-11-05087"><label>38.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yun</surname><given-names>Y</given-names></name><name><surname>Dong</surname><given-names>Z</given-names></name><name><surname>Shanov</surname><given-names>V</given-names></name><name><surname>Heineman</surname><given-names>WR</given-names></name><name><surname>Halsall</surname><given-names>HB</given-names></name><name><surname>Bhattacharya</surname><given-names>A</given-names></name><name><surname>Conforti</surname><given-names>L</given-names></name><name><surname>Narayan</surname><given-names>RK</given-names></name><name><surname>Ball</surname><given-names>WS</given-names></name><name><surname>Schulz</surname><given-names>MJ</given-names></name></person-group><article-title>Nanotube electrodes and biosensors</article-title><source>Nanotoday</source><year>2007</year><volume>2</volume><fpage>30</fpage><lpage>37</lpage></citation></ref>
<ref id="b39-sensors-11-05087"><label>39.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>He</surname><given-names>HX</given-names></name><name><surname>Li</surname><given-names>CZ</given-names></name><name><surname>Tao</surname><given-names>NJ</given-names></name></person-group><article-title>Conductance of polymer nanowires fabricated by a combined electrodeposition and mechanical break junction method</article-title><source>Appl. Phys. Lett</source><year>2001</year><volume>78</volume><fpage>811</fpage><lpage>813</lpage><pub-id pub-id-type="doi">10.1063/1.1335551</pub-id></citation></ref>
<ref id="b40-sensors-11-05087"><label>40.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Clark</surname><given-names>LC</given-names><suffix>Jr</suffix></name><name><surname>Lyons</surname><given-names>C</given-names></name><name><surname>Ann</surname><given-names>NY</given-names></name></person-group><article-title>Electrode systems for continuous monitoring in cardiovascular surgery</article-title><source>Acad. Sci</source><year>1962</year><volume>102</volume><fpage>29</fpage><lpage>45</lpage></citation></ref>
<ref id="b41-sensors-11-05087"><label>41.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hernandez</surname><given-names>RM</given-names></name><name><surname>Richter</surname><given-names>L</given-names></name><name><surname>Semancik</surname><given-names>S</given-names></name><name><surname>Stranick</surname><given-names>S</given-names></name><name><surname>Mallouk</surname><given-names>TE</given-names></name></person-group><article-title>Template fabrication of protein functionalized gold-polypyrrole-gold segmented nanowires</article-title><source>Chem. Mater</source><year>2004</year><volume>16</volume><fpage>3431</fpage><lpage>3438</lpage><pub-id pub-id-type="doi">10.1021/cm0496265</pub-id></citation></ref>
<ref id="b42-sensors-11-05087"><label>42.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ramanathan</surname><given-names>K</given-names></name><name><surname>Bangar</surname><given-names>MA</given-names></name><name><surname>Yun</surname><given-names>M</given-names></name><name><surname>Chen</surname><given-names>W</given-names></name><name><surname>Myung</surname><given-names>NV</given-names></name><name><surname>Mulchandani</surname><given-names>A</given-names></name></person-group><article-title>Bioaffinity sensing using biologically functionalized conducting polymer nanowire</article-title><source>J. Am. Chem. Soc</source><year>2005</year><volume>127</volume><fpage>496</fpage><lpage>497</lpage><pub-id pub-id-type="doi">10.1021/ja044486l</pub-id><pub-id pub-id-type="pmid">15643853</pub-id></citation></ref>
<ref id="b43-sensors-11-05087"><label>43.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bangar</surname><given-names>MA</given-names></name><name><surname>Shirale</surname><given-names>DJ</given-names></name><name><surname>Chen</surname><given-names>W</given-names></name><name><surname>Myung</surname><given-names>NV</given-names></name><name><surname>Mulchandani</surname><given-names>A</given-names></name></person-group><article-title>Single conducting polymer nanowire chemiresistive label free immunosensor for cancer biomarker</article-title><source>Anal. Chem</source><year>2009</year><volume>81</volume><fpage>2168</fpage><lpage>2175</lpage><pub-id pub-id-type="doi">10.1021/ac802319f</pub-id><pub-id pub-id-type="pmid">19281260</pub-id></citation></ref>
<ref id="b44-sensors-11-05087"><label>44.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dan</surname><given-names>Y</given-names></name><name><surname>Cao</surname><given-names>Y</given-names></name><name><surname>Mallouk</surname><given-names>TE</given-names></name><name><surname>Johnson</surname><given-names>AT</given-names></name><name><surname>Evoy</surname><given-names>S</given-names></name></person-group><article-title>Dielectrophoretically assembled polymer nanowires for gas sensing</article-title><source>Sens. Actuat. B</source><year>2007</year><volume>125</volume><fpage>55</fpage><lpage>59</lpage><pub-id pub-id-type="doi">10.1016/j.snb.2007.01.042</pub-id></citation></ref>
<ref id="b45-sensors-11-05087"><label>45.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhao</surname><given-names>Q</given-names></name><name><surname>Gan</surname><given-names>Z</given-names></name><name><surname>Zhuang</surname><given-names>Q</given-names></name></person-group><article-title>Electrochemical sensors based on carbon nanotubes</article-title><source>Electroanalysis</source><year>2002</year><volume>14</volume><fpage>1609</fpage><lpage>1613</lpage><pub-id pub-id-type="doi">10.1002/elan.200290000</pub-id></citation></ref>
<ref id="b46-sensors-11-05087"><label>46.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Musameh</surname><given-names>M</given-names></name><name><surname>Wang</surname><given-names>J</given-names></name><name><surname>Merkoci</surname><given-names>A</given-names></name><name><surname>Lin</surname><given-names>Y</given-names></name></person-group><article-title>Low potential stable NADH detection at carbon nanotube modified glassy carbon electrodes</article-title><source>Electrochem. Commun</source><year>2002</year><volume>4</volume><fpage>743</fpage><lpage>746</lpage><pub-id pub-id-type="doi">10.1016/S1388-2481(02)00451-4</pub-id></citation></ref>
<ref id="b47-sensors-11-05087"><label>47.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gooding</surname><given-names>JJ</given-names></name><name><surname>Wibowo</surname><given-names>R</given-names></name><name><surname>Liu</surname><given-names>JQ</given-names></name><name><surname>Yang</surname><given-names>W</given-names></name><name><surname>Losic</surname><given-names>D</given-names></name><name><surname>Orbons</surname><given-names>S</given-names></name><name><surname>Mearns</surname><given-names>FJ</given-names></name><name><surname>Shapter</surname><given-names>JG</given-names></name><name><surname>Hibbert</surname><given-names>DB</given-names></name></person-group><article-title>Protein electrochemistry using aligned carbon nanotube arrays</article-title><source>J. Am. Chem. Soc</source><year>2003</year><volume>125</volume><fpage>9006</fpage><lpage>9007</lpage><pub-id pub-id-type="doi">10.1021/ja035722f</pub-id><pub-id pub-id-type="pmid">15369344</pub-id></citation></ref>
<ref id="b48-sensors-11-05087"><label>48.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yu</surname><given-names>X</given-names></name><name><surname>Chattopadhyay</surname><given-names>D</given-names></name><name><surname>Galeska</surname><given-names>I</given-names></name><name><surname>Papadimitrakopoulos</surname><given-names>F</given-names></name><name><surname>Rusling</surname><given-names>JF</given-names></name></person-group><article-title>Peroxidase activity of enzymes bound to the ends of single walled carbon nanotube forest electrodes</article-title><source>Electrochem. Commun</source><year>2003</year><volume>5</volume><fpage>408</fpage><lpage>411</lpage><pub-id pub-id-type="doi">10.1016/S1388-2481(03)00076-6</pub-id></citation></ref>
<ref id="b49-sensors-11-05087"><label>49.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Iijima</surname><given-names>S</given-names></name><name><surname>Ichihashi</surname><given-names>T</given-names></name></person-group><article-title>Single shell carbon nanotubes of 1nm diameter</article-title><source>Nature</source><year>1993</year><volume>363</volume><fpage>603</fpage><lpage>605</lpage><pub-id pub-id-type="doi">10.1038/363603a0</pub-id></citation></ref>
<ref id="b50-sensors-11-05087"><label>50.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bethune</surname><given-names>DS</given-names></name><name><surname>Kiang</surname><given-names>CH</given-names></name><name><surname>de Vries</surname><given-names>MS</given-names></name><name><surname>Gorman</surname><given-names>G</given-names></name><name><surname>Savoy</surname><given-names>R</given-names></name><name><surname>Vazquez</surname><given-names>J</given-names></name><name><surname>Beyers</surname><given-names>R</given-names></name></person-group><article-title>Cobalt-catalysed growth of carbon nanotubes with single-atomic-layer walls</article-title><source>Nature</source><year>1993</year><volume>363</volume><fpage>605</fpage><lpage>606</lpage><pub-id pub-id-type="doi">10.1038/363605a0</pub-id></citation></ref>
<ref id="b51-sensors-11-05087"><label>51.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Davis</surname><given-names>JJ</given-names></name><name><surname>Coleman</surname><given-names>K</given-names></name><name><surname>Azamian</surname><given-names>B</given-names></name><name><surname>Bagshaw</surname><given-names>C</given-names></name><name><surname>Green</surname><given-names>ML</given-names></name></person-group><article-title>Chemical and biochemical sensing with modified single walled carbon nanotubes</article-title><source>Chem. Eur. J</source><year>2003</year><volume>9</volume><fpage>3732</fpage><lpage>3739</lpage><pub-id pub-id-type="doi">10.1002/chem.200304872</pub-id><pub-id pub-id-type="pmid">12916096</pub-id></citation></ref>
<ref id="b52-sensors-11-05087"><label>52.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Baughman</surname><given-names>RH</given-names></name><name><surname>Zakhidov</surname><given-names>A</given-names></name><name><surname>de Heer</surname><given-names>WA</given-names></name></person-group><article-title>Carbon nanotubes—The route toward applications</article-title><source>Science</source><year>2002</year><volume>297</volume><fpage>787</fpage><lpage>792</lpage><pub-id pub-id-type="doi">10.1126/science.1060928</pub-id><pub-id pub-id-type="pmid">12161643</pub-id></citation></ref>
<ref id="b53-sensors-11-05087"><label>53.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Khare</surname><given-names>R</given-names></name><name><surname>Bose</surname><given-names>S</given-names></name></person-group><article-title>Carbon nanotube based composites—A review</article-title><source>J. Miner. Mater. Character. Eng</source><year>2005</year><volume>4</volume><fpage>31</fpage><lpage>46</lpage></citation></ref>
<ref id="b54-sensors-11-05087"><label>54.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Maehashi</surname><given-names>K</given-names></name><name><surname>Matsumoto</surname><given-names>K</given-names></name></person-group><article-title>Label free electrical detection using carbon nanoptube based biosensors</article-title><source>Sensors</source><year>2009</year><volume>9</volume><fpage>5368</fpage><lpage>5378</lpage><pub-id pub-id-type="doi">10.3390/s90705368</pub-id><pub-id pub-id-type="pmid">22346703</pub-id></citation></ref>
<ref id="b55-sensors-11-05087"><label>55.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huang</surname><given-names>Y</given-names></name><name><surname>Duan</surname><given-names>X</given-names></name><name><surname>Wei</surname><given-names>Q</given-names></name><name><surname>Lieber</surname><given-names>CM</given-names></name></person-group><article-title>Directed assembly of one dimensional nanostructures into functional networks</article-title><source>Science</source><year>2001</year><volume>291</volume><fpage>630</fpage><lpage>633</lpage><pub-id pub-id-type="doi">10.1126/science.291.5504.630</pub-id><pub-id pub-id-type="pmid">11158671</pub-id></citation></ref>
<ref id="b56-sensors-11-05087"><label>56.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname><given-names>Y</given-names></name><name><surname>Chang</surname><given-names>A</given-names></name><name><surname>Cao</surname><given-names>J</given-names></name><name><surname>Wang</surname><given-names>Q</given-names></name><name><surname>Kim</surname><given-names>W</given-names></name><name><surname>Li</surname><given-names>Y</given-names></name><name><surname>Morris</surname><given-names>N</given-names></name><name><surname>Yenilmez</surname><given-names>E</given-names></name><name><surname>Kong</surname><given-names>J</given-names></name><name><surname>Dai</surname><given-names>H</given-names></name></person-group><article-title>Electric-field directed growth of aligned single wall carbon nanotubes</article-title><source>Appl. Phys. Lett</source><year>2001</year><volume>79</volume><fpage>3155</fpage><lpage>3157</lpage><pub-id pub-id-type="doi">10.1063/1.1415412</pub-id></citation></ref>
<ref id="b57-sensors-11-05087"><label>57.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Gao</surname><given-names>J</given-names></name><name><surname>Yu</surname><given-names>A</given-names></name><name><surname>Itkis</surname><given-names>ME</given-names></name><name><surname>Bekyarova</surname><given-names>E</given-names></name><name><surname>Zhao</surname><given-names>B</given-names></name><name><surname>Niyogi</surname><given-names>S</given-names></name><name><surname>Haddon</surname><given-names>RC</given-names></name></person-group><article-title>Large scale fabrication of aligned single walled carbon nanotube array and hierarchical single walled carbon nanotube assembly</article-title><source>J. Am. Chem. Soc</source><year>2004</year><volume>126</volume><fpage>16698</fpage><lpage>16699</lpage><pub-id pub-id-type="doi">10.1021/ja044499z</pub-id><pub-id pub-id-type="pmid">15612688</pub-id></citation></ref>
<ref id="b58-sensors-11-05087"><label>58.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Druzhinina</surname><given-names>T</given-names></name><name><surname>Hoeppener</surname><given-names>S</given-names></name><name><surname>Schubert</surname><given-names>US</given-names></name></person-group><article-title>Strategies for Post-Synthesis Alignment and Immobilization of Carbon Nanotubes</article-title><source>Adv. Mater</source><year>2011</year><volume>23</volume><fpage>953</fpage><lpage>970</lpage><pub-id pub-id-type="doi">10.1002/adma.201003509</pub-id><pub-id pub-id-type="pmid">21181769</pub-id></citation></ref>
<ref id="b59-sensors-11-05087"><label>59.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kumar</surname><given-names>MS</given-names></name><name><surname>Lee</surname><given-names>SH</given-names></name><name><surname>Kim</surname><given-names>TY</given-names></name><name><surname>Kim</surname><given-names>TH</given-names></name><name><surname>Song</surname><given-names>SM</given-names></name><name><surname>Yang</surname><given-names>JW</given-names></name><name><surname>Nahm</surname><given-names>KS</given-names></name><name><surname>Suh</surname><given-names>EK</given-names></name></person-group><article-title>DC electric field assisted alignment of carbon nanotubes on metal electrodes</article-title><source>Solid State Elect</source><year>2003</year><volume>47</volume><fpage>2075</fpage><lpage>2080</lpage><pub-id pub-id-type="doi">10.1016/S0038-1101(03)00258-2</pub-id></citation></ref>
<ref id="b60-sensors-11-05087"><label>60.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname><given-names>Y</given-names></name><name><surname>Chung</surname><given-names>J-H</given-names></name><name><surname>Liu</surname><given-names>WK</given-names></name><name><surname>Ruoff</surname><given-names>RS</given-names></name></person-group><article-title>Dielectrophoretic assembly of nanowires</article-title><source>J. Phys. Chem. B</source><year>2006</year><volume>110</volume><fpage>14098</fpage><lpage>14106</lpage><pub-id pub-id-type="doi">10.1021/jp061367e</pub-id><pub-id pub-id-type="pmid">16854106</pub-id></citation></ref>
<ref id="b61-sensors-11-05087"><label>61.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chung</surname><given-names>J</given-names></name><name><surname>Lee</surname><given-names>J</given-names></name></person-group><article-title>Nanoscale gap fabrication and integration of carbon nanotubes by micromachining</article-title><source>Sens. Actuat. A</source><year>2003</year><volume>104</volume><fpage>229</fpage><lpage>235</lpage><pub-id pub-id-type="doi">10.1016/S0924-4247(03)00025-6</pub-id></citation></ref>
<ref id="b62-sensors-11-05087"><label>62.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chung</surname><given-names>J</given-names></name><name><surname>Lee</surname><given-names>K-H</given-names></name><name><surname>Lee</surname><given-names>J</given-names></name><name><surname>Ruoff</surname><given-names>RS</given-names></name></person-group><article-title>Toward large-scale integration of carbon nanotubes</article-title><source>Langmuir</source><year>2004</year><volume>20</volume><fpage>3011</fpage><lpage>3017</lpage><pub-id pub-id-type="doi">10.1021/la035726y</pub-id><pub-id pub-id-type="pmid">15875821</pub-id></citation></ref>
<ref id="b63-sensors-11-05087"><label>63.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Matsui</surname><given-names>H</given-names></name><name><surname>Gologan</surname><given-names>B</given-names></name></person-group><article-title>Crystalline glycylglycine bolaamphiphile tubules and their ph sensitive structural transformation</article-title><source>J. Phys. Chem. B</source><year>2000</year><volume>104</volume><fpage>3383</fpage><lpage>3386</lpage><pub-id pub-id-type="doi">10.1021/jp994117p</pub-id></citation></ref>
<ref id="b64-sensors-11-05087"><label>64.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kogiso</surname><given-names>M</given-names></name><name><surname>Ohnishi</surname><given-names>S</given-names></name><name><surname>Yase</surname><given-names>K</given-names></name><name><surname>Masuda</surname><given-names>M</given-names></name><name><surname>Shimizu</surname><given-names>T</given-names></name></person-group><article-title>Dicarboxylic oligopeptide bolaamphiphiles: Proton triggered self assembly of microtubes with loose solid surfaces</article-title><source>Langmuir</source><year>1998</year><volume>14</volume><fpage>4978</fpage><lpage>4986</lpage><pub-id pub-id-type="doi">10.1021/la9802419</pub-id></citation></ref>
<ref id="b65-sensors-11-05087"><label>65.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Djalali</surname><given-names>R</given-names></name><name><surname>Chen</surname><given-names>Y-F</given-names></name><name><surname>Matsui</surname><given-names>H</given-names></name></person-group><article-title>Au nanocrystal growth on nanotubes controlled by conformations and charges of sequenced peptide templates</article-title><source>J. Am. Chem. Soc</source><year>2003</year><volume>125</volume><fpage>5873</fpage><lpage>5879</lpage><pub-id pub-id-type="doi">10.1021/ja0299598</pub-id><pub-id pub-id-type="pmid">12733928</pub-id></citation></ref>
<ref id="b66-sensors-11-05087"><label>66.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Djalali</surname><given-names>R</given-names></name><name><surname>Chen</surname><given-names>Y-F</given-names></name><name><surname>Matsui</surname><given-names>H</given-names></name></person-group><article-title>Au nanowire fabrication from sequenced histidine rich peptide</article-title><source>J. Am. Chem. Soc</source><year>2002</year><volume>124</volume><fpage>13660</fpage><lpage>13661</lpage><pub-id pub-id-type="doi">10.1021/ja028261r</pub-id><pub-id pub-id-type="pmid">12431080</pub-id></citation></ref>
<ref id="b67-sensors-11-05087"><label>67.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>O’Connor</surname><given-names>M</given-names></name><name><surname>Kim</surname><given-names>SN</given-names></name><name><surname>Killard</surname><given-names>AJ</given-names></name><name><surname>Forster</surname><given-names>RJ</given-names></name><name><surname>Smyth</surname><given-names>MR</given-names></name><name><surname>Papadimitrakopoulos</surname><given-names>F</given-names></name><name><surname>Rusling</surname><given-names>JF</given-names></name></person-group><article-title>Mediated amperometric immunosensing using single walled carbon nanotube forests</article-title><source>Analyst</source><year>2004</year><volume>129</volume><fpage>1176</fpage><lpage>1180</lpage><pub-id pub-id-type="doi">10.1039/b412805b</pub-id><pub-id pub-id-type="pmid">15565214</pub-id></citation></ref>
<ref id="b68-sensors-11-05087"><label>68.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Fu</surname><given-names>K</given-names></name><name><surname>Sun</surname><given-names>YP</given-names></name></person-group><article-title>Dispersion and solubilization of carbon nanotubes</article-title><source>J. Nanosci. Nanotechnol</source><year>2003</year><volume>3</volume><fpage>351</fpage><lpage>364</lpage><pub-id pub-id-type="doi">10.1166/jnn.2003.225</pub-id><pub-id pub-id-type="pmid">14733142</pub-id></citation></ref>
<ref id="b69-sensors-11-05087"><label>69.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huang</surname><given-names>TS</given-names></name><name><surname>Tzeng</surname><given-names>Y</given-names></name><name><surname>Liu</surname><given-names>YK</given-names></name><name><surname>Chen</surname><given-names>YC</given-names></name><name><surname>Alker</surname><given-names>KRW</given-names></name><name><surname>Guntupalli</surname><given-names>R</given-names></name><name><surname>Liu</surname><given-names>C</given-names></name></person-group><article-title>Immobilization of antibodies and bacterial binding on nanodiamond and carbon nanotubes for biosensor applications</article-title><source>Diamond Relat. Mater</source><year>2004</year><volume>13</volume><fpage>1098</fpage><lpage>1102</lpage><pub-id pub-id-type="doi">10.1016/j.diamond.2003.11.047</pub-id></citation></ref>
<ref id="b70-sensors-11-05087"><label>70.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Huang</surname><given-names>W</given-names></name><name><surname>Taylor</surname><given-names>S</given-names></name><name><surname>Fu</surname><given-names>K</given-names></name><name><surname>Lin</surname><given-names>Y</given-names></name><name><surname>Zhang</surname><given-names>D</given-names></name><name><surname>Hanks</surname><given-names>TW</given-names></name><name><surname>Rao</surname><given-names>AM</given-names></name><name><surname>Sun</surname><given-names>YP</given-names></name></person-group><article-title>Attaching proteins to carbon nanotubes via diimide activated amidation</article-title><source>Nano Lett</source><year>2002</year><volume>2</volume><fpage>311</fpage><lpage>314</lpage><pub-id pub-id-type="doi">10.1021/nl010095i</pub-id></citation></ref>
<ref id="b71-sensors-11-05087"><label>71.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dwyer</surname><given-names>C</given-names></name><name><surname>Guthold</surname><given-names>M</given-names></name><name><surname>Falvo</surname><given-names>M</given-names></name><name><surname>Washburn</surname><given-names>S</given-names></name><name><surname>Superfine</surname><given-names>R</given-names></name><name><surname>Erie</surname><given-names>D</given-names></name></person-group><article-title>DNA functionalized single walled carbon nanotubes</article-title><source>Nanotechnology</source><year>2002</year><volume>13</volume><fpage>601</fpage><lpage>604</lpage><pub-id pub-id-type="doi">10.1088/0957-4484/13/5/311</pub-id></citation></ref>
<ref id="b72-sensors-11-05087"><label>72.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zheng</surname><given-names>M</given-names></name><name><surname>Jagota</surname><given-names>A</given-names></name><name><surname>Semke</surname><given-names>ED</given-names></name><name><surname>Diner</surname><given-names>BA</given-names></name><name><surname>McLean</surname><given-names>RS</given-names></name><name><surname>Lustig</surname><given-names>SR</given-names></name><name><surname>Richardson</surname><given-names>RE</given-names></name><name><surname>Tassi</surname><given-names>NG</given-names></name></person-group><article-title>DNA assisted dispersion and separation of carbon nanotubes</article-title><source>Nat. Mater</source><year>2003</year><volume>2</volume><fpage>338</fpage><lpage>342</lpage><pub-id pub-id-type="doi">10.1038/nmat877</pub-id><pub-id pub-id-type="pmid">12692536</pub-id></citation></ref>
<ref id="b73-sensors-11-05087"><label>73.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Bekyarova</surname><given-names>E</given-names></name><name><surname>Ni</surname><given-names>Y</given-names></name><name><surname>Malarkey</surname><given-names>EB</given-names></name><name><surname>Montana</surname><given-names>V</given-names></name><name><surname>McWilliams</surname><given-names>JL</given-names></name><name><surname>Haddon</surname><given-names>RC</given-names></name><name><surname>Parpura</surname><given-names>V</given-names></name></person-group><article-title>Applications of carbon nanotubes in biotechnology and biomedicine</article-title><source>J. Biomed. Nanotechnol</source><year>2005</year><volume>1</volume><fpage>3</fpage><lpage>17</lpage><pub-id pub-id-type="doi">10.1166/jbn.2005.004</pub-id><pub-id pub-id-type="pmid">19763242</pub-id></citation></ref>
<ref id="b74-sensors-11-05087"><label>74.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Jithesh</surname><given-names>V</given-names></name><name><surname>Ye</surname><given-names>Y</given-names></name></person-group><article-title>Development of immunosensors using carbon nanotubes</article-title><source>Biotechnol. Prog</source><year>2007</year><volume>23</volume><fpage>517</fpage><lpage>531</lpage><pub-id pub-id-type="pmid">17458980</pub-id></citation></ref>
<ref id="b75-sensors-11-05087"><label>75.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Besteman</surname><given-names>K</given-names></name><name><surname>Lee</surname><given-names>JO</given-names></name><name><surname>Wiertz</surname><given-names>FG</given-names></name><name><surname>Heering</surname><given-names>HA</given-names></name><name><surname>Dekker</surname><given-names>C</given-names></name></person-group><article-title>Enzyme coated carbon nanotubes as single molecule biosensors</article-title><source>Nano Lett</source><year>2003</year><volume>3</volume><fpage>727</fpage><lpage>730</lpage><pub-id pub-id-type="doi">10.1021/nl034139u</pub-id></citation></ref>
<ref id="b76-sensors-11-05087"><label>76.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname><given-names>RJ</given-names></name><name><surname>Bangsaruntip</surname><given-names>S</given-names></name><name><surname>Drouvalakis</surname><given-names>KA</given-names></name><name><surname>Kam</surname><given-names>NWS</given-names></name><name><surname>Shim</surname><given-names>M</given-names></name><name><surname>Li</surname><given-names>Y</given-names></name><name><surname>Kim</surname><given-names>W</given-names></name><name><surname>Utz</surname><given-names>PJ</given-names></name><name><surname>Dai</surname><given-names>H</given-names></name></person-group><article-title>Non covalent functionalization of carbon nanotubes for highly specific electronic biosensors</article-title><source>Proc. Natl. Acad. Sci. USA</source><year>2003</year><volume>100</volume><fpage>4984</fpage><lpage>4989</lpage><pub-id pub-id-type="doi">10.1073/pnas.0837064100</pub-id><pub-id pub-id-type="pmid">12697899</pub-id></citation></ref>
<ref id="b77-sensors-11-05087"><label>77.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Boussaad</surname><given-names>S</given-names></name><name><surname>Tao</surname><given-names>NJ</given-names></name><name><surname>Zhang</surname><given-names>R</given-names></name><name><surname>Hopson</surname><given-names>T</given-names></name><name><surname>Nagahara</surname><given-names>LA</given-names></name></person-group><article-title><italic>In situ</italic> detection of cytochrome C adsorption with single walled carbon nanotube device</article-title><source>Chem Commun</source><year>2003</year><pub-id pub-id-type="doi">10.1039/B302681G.</pub-id></citation></ref>
<ref id="b78-sensors-11-05087"><label>78.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wohlstadter</surname><given-names>JN</given-names></name><name><surname>Wilbur</surname><given-names>JL</given-names></name><name><surname>Sigal</surname><given-names>GB</given-names></name><name><surname>Biebuyck</surname><given-names>HA</given-names></name><name><surname>Billadeau</surname><given-names>MA</given-names></name><name><surname>Dong</surname><given-names>L</given-names></name><name><surname>Fischer</surname><given-names>AB</given-names></name><name><surname>Gudibande</surname><given-names>SR</given-names></name><name><surname>Jameison</surname><given-names>SH</given-names></name><name><surname>Kenten</surname><given-names>JH</given-names></name><name><surname>Leginus</surname><given-names>J</given-names></name><name><surname>Leland</surname><given-names>JK</given-names></name><name><surname>Massey</surname><given-names>RJ</given-names></name><name><surname>Wohlstadter</surname><given-names>S</given-names></name></person-group><article-title>Carbon nanotube based biosensor</article-title><source>J. Adv. Mater</source><year>2003</year><volume>15</volume><fpage>1184</fpage><lpage>1187</lpage><pub-id pub-id-type="doi">10.1002/adma.200304259</pub-id></citation></ref>
<ref id="b79-sensors-11-05087"><label>79.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Keren</surname><given-names>K</given-names></name><name><surname>Berman</surname><given-names>RS</given-names></name><name><surname>Buchstab</surname><given-names>E</given-names></name><name><surname>Sivan</surname><given-names>U</given-names></name><name><surname>Braun</surname><given-names>E</given-names></name></person-group><article-title>DNA template carbon nanotube field effect transistor</article-title><source>Science</source><year>2003</year><volume>302</volume><fpage>1380</fpage><lpage>1382</lpage><pub-id pub-id-type="doi">10.1126/science.1091022</pub-id><pub-id pub-id-type="pmid">14631035</pub-id></citation></ref>
<ref id="b80-sensors-11-05087"><label>80.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Star</surname><given-names>A</given-names></name><name><surname>Gabriel</surname><given-names>JCP</given-names></name><name><surname>Bradley</surname><given-names>K</given-names></name><name><surname>Gruner</surname><given-names>G</given-names></name></person-group><article-title>Electronic detection of specific protein binding using nanotube FET devices</article-title><source>Nano Lett</source><year>2003</year><volume>3</volume><fpage>459</fpage><lpage>463</lpage><pub-id pub-id-type="doi">10.1021/nl0340172</pub-id></citation></ref>
<ref id="b81-sensors-11-05087"><label>81.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname><given-names>J</given-names></name><name><surname>Goud</surname><given-names>J</given-names></name><name><surname>Raj</surname><given-names>PM</given-names></name><name><surname>Iyer</surname><given-names>M</given-names></name><name><surname>Wang</surname><given-names>ZL</given-names></name><name><surname>Tummala</surname><given-names>RR</given-names></name></person-group><article-title>Real time protein detection using ZnO nanowire/thin film biosensor integrated with microfluidic system</article-title><source>IEEE ECTC</source><year>2008</year><volume>58</volume><fpage>1317</fpage><lpage>1322</lpage></citation></ref>
<ref id="b82-sensors-11-05087"><label>82.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lévy-Clément</surname><given-names>C</given-names></name><name><surname>Tena-Zaera</surname><given-names>R</given-names></name><name><surname>Ryan</surname><given-names>MA</given-names></name><name><surname>Katty</surname><given-names>A</given-names></name><name><surname>Hodes</surname><given-names>G</given-names></name></person-group><article-title>Nanostructured CdSe sensitized p-CuSCN/nanowire n-ZnO heterojunctions</article-title><source>Adv. Mater</source><year>2005</year><volume>17</volume><fpage>1512</fpage><lpage>1515</lpage><pub-id pub-id-type="doi">10.1002/adma.200401848</pub-id></citation></ref>
<ref id="b83-sensors-11-05087"><label>83.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Law</surname><given-names>M</given-names></name><name><surname>Greene</surname><given-names>LE</given-names></name><name><surname>Johnson</surname><given-names>JC</given-names></name><name><surname>Saykally</surname><given-names>R</given-names></name><name><surname>Yang</surname><given-names>R</given-names></name></person-group><article-title>Nanowire dye sensitized solar cells</article-title><source>Nat. Mater</source><year>2005</year><volume>4</volume><fpage>455</fpage><lpage>459</lpage><pub-id pub-id-type="doi">10.1038/nmat1387</pub-id><pub-id pub-id-type="pmid">15895100</pub-id></citation></ref>
<ref id="b84-sensors-11-05087"><label>84.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Diettrich</surname><given-names>T</given-names></name><name><surname>Koeven</surname><given-names>D</given-names></name><name><surname>Rusu</surname><given-names>M</given-names></name><name><surname>Belaidi</surname><given-names>A</given-names></name><name><surname>Tornow</surname><given-names>J</given-names></name><name><surname>Schwartzburg</surname><given-names>K</given-names></name><name><surname>Lux-Steiner</surname><given-names>M</given-names></name></person-group><article-title>Current voltage characteristics and mechanism of solar cells based on ZnO nanrods/In2S3/CuSCN</article-title><source>Appl. Phys. Lett</source><year>2008</year><volume>93</volume><fpage>053113</fpage><pub-id pub-id-type="doi">10.1063/1.2969291</pub-id></citation></ref>
<ref id="b85-sensors-11-05087"><label>85.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tien</surname><given-names>LC</given-names></name><name><surname>Sadik</surname><given-names>PW</given-names></name><name><surname>Norton</surname><given-names>DP</given-names></name><name><surname>Voss</surname><given-names>LF</given-names></name><name><surname>Pearton</surname><given-names>SJ</given-names></name><name><surname>Wang</surname><given-names>HT</given-names></name><name><surname>Kang</surname><given-names>BS</given-names></name><name><surname>Ren</surname><given-names>F</given-names></name><name><surname>Jun</surname><given-names>J</given-names></name><name><surname>Lin</surname><given-names>J</given-names></name></person-group><article-title>Hydrogen sensing at room temperature with Pt-coated ZnO thin films and nanorods</article-title><source>Appl. Phys. Lett</source><year>2005</year><volume>87</volume><fpage>222106</fpage><pub-id pub-id-type="doi">10.1063/1.2136070</pub-id></citation></ref>
<ref id="b86-sensors-11-05087"><label>86.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Könenkamp</surname><given-names>R</given-names></name><name><surname>Word</surname><given-names>R</given-names></name><name><surname>Godinez</surname><given-names>M</given-names></name></person-group><article-title>Ultraviolet electroluminescence from ZnO/polymer heterojunction light emitting diodes</article-title><source>Nano Lett</source><year>2005</year><volume>5</volume><fpage>2005</fpage><lpage>2008</lpage><pub-id pub-id-type="doi">10.1021/nl051501r</pub-id><pub-id pub-id-type="pmid">16218727</pub-id></citation></ref>
<ref id="b87-sensors-11-05087"><label>87.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname><given-names>XT</given-names></name><name><surname>Sato</surname><given-names>O</given-names></name><name><surname>Fujishima</surname><given-names>A</given-names></name></person-group><article-title>Water ultrarepellency induced by nanocolumnar ZnO surface</article-title><source>Langmuir</source><year>2004</year><volume>20</volume><fpage>6065</fpage><lpage>6067</lpage><pub-id pub-id-type="doi">10.1021/la049471f</pub-id><pub-id pub-id-type="pmid">16459630</pub-id></citation></ref>
<ref id="b88-sensors-11-05087"><label>88.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Badre</surname><given-names>C</given-names></name><name><surname>Pauporte</surname><given-names>T</given-names></name><name><surname>Turmine</surname><given-names>M</given-names></name><name><surname>Lincot</surname><given-names>D</given-names></name></person-group><article-title>A Zno array nanofilm with stable high water repellent properties</article-title><source>Nanotechnology</source><year>2007</year><volume>18</volume><fpage>365705</fpage><pub-id pub-id-type="doi">10.1088/0957-4484/18/36/365705</pub-id></citation></ref>
<ref id="b89-sensors-11-05087"><label>89.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Badre</surname><given-names>C</given-names></name><name><surname>Pauporte</surname><given-names>T</given-names></name><name><surname>Turmine</surname><given-names>M</given-names></name><name><surname>Dubot</surname><given-names>P</given-names></name><name><surname>Lincot</surname><given-names>D</given-names></name></person-group><article-title>Water repllent ZnO nanowires obtained by octadecysilane self assembled monolayers</article-title><source>Phys. E</source><year>2008</year><volume>40</volume><fpage>2454</fpage><lpage>2456</lpage><pub-id pub-id-type="doi">10.1016/j.physe.2007.10.016</pub-id></citation></ref>
<ref id="b90-sensors-11-05087"><label>90.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Xiang</surname><given-names>B</given-names></name><name><surname>Wang</surname><given-names>P</given-names></name><name><surname>Zhang</surname><given-names>X</given-names></name><name><surname>Dayeh</surname><given-names>SA</given-names></name><name><surname>Aplin</surname><given-names>DPR</given-names></name><name><surname>Soci</surname><given-names>C</given-names></name><name><surname>Yu</surname><given-names>D</given-names></name><name><surname>Wang</surname><given-names>D</given-names></name></person-group><article-title>Rational synthesis of p-type ZnO arrays using simple chemical vapor deposition</article-title><source>Nano Lett</source><year>2007</year><volume>7</volume><fpage>323</fpage><lpage>328</lpage><pub-id pub-id-type="doi">10.1021/nl062410c</pub-id><pub-id pub-id-type="pmid">17297995</pub-id></citation></ref>
<ref id="b91-sensors-11-05087"><label>91.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zhang</surname><given-names>XH</given-names></name><name><surname>Chua</surname><given-names>SJ</given-names></name><name><surname>Yong</surname><given-names>AM</given-names></name><name><surname>Yang</surname><given-names>HY</given-names></name><name><surname>Lau</surname><given-names>SP</given-names></name><name><surname>Yu</surname><given-names>SF</given-names></name><name><surname>Sun</surname><given-names>WW</given-names></name><name><surname>Miao</surname><given-names>L</given-names></name><name><surname>Tanemura</surname><given-names>M</given-names></name><name><surname>Tanemura</surname><given-names>S</given-names></name></person-group><article-title>Exciton radiative lifetime in ZnO nanorods fabricated by vapor phase transport method</article-title><source>Appl. Phys. Lett</source><year>2007</year><volume>90</volume><fpage>013107</fpage><pub-id pub-id-type="doi">10.1063/1.2429019</pub-id></citation></ref>
<ref id="b92-sensors-11-05087"><label>92.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Sun</surname><given-names>Y</given-names></name><name><surname>Fuge</surname><given-names>GM</given-names></name><name><surname>Ashfold</surname><given-names>MNR</given-names></name></person-group><article-title>Growth of aligned ZnO nanorod arrays by catalyst-free pulsed laser deposition methods</article-title><source>Chem. Phys. Lett</source><year>2004</year><volume>396</volume><fpage>21</fpage><lpage>26</lpage><pub-id pub-id-type="doi">10.1016/j.cplett.2004.07.110</pub-id></citation></ref>
<ref id="b93-sensors-11-05087"><label>93.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Vayssières</surname><given-names>L</given-names></name></person-group><article-title>Growth of arrayed nanorods and of nanowires of ZnO from aqueous solutions</article-title><source>Adv. Mater</source><year>2003</year><volume>15</volume><fpage>464</fpage><lpage>466</lpage><pub-id pub-id-type="doi">10.1002/adma.200390108</pub-id></citation></ref>
<ref id="b94-sensors-11-05087"><label>94.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Krunks</surname><given-names>M</given-names></name><name><surname>Dedova</surname><given-names>T</given-names></name><name><surname>Açik</surname><given-names>IO</given-names></name></person-group><article-title>Spray pyrolysis deposition of zinc oxide nanostructured layers</article-title><source>Thin Solid Films</source><year>2006</year><volume>515</volume><fpage>1157</fpage><lpage>1160</lpage><pub-id pub-id-type="doi">10.1016/j.tsf.2006.07.134</pub-id></citation></ref>
<ref id="b95-sensors-11-05087"><label>95.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Peulon</surname><given-names>S</given-names></name><name><surname>Lincot</surname><given-names>D</given-names></name></person-group><article-title>Cathodic electrodeposition from aqueous solution of dense or open-structured zinc oxide films</article-title><source>Adv. Mater</source><year>1996</year><volume>8</volume><fpage>166</fpage><lpage>170</lpage><pub-id pub-id-type="doi">10.1002/adma.19960080216</pub-id></citation></ref>
<ref id="b96-sensors-11-05087"><label>96.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Yogeswaran</surname><given-names>U</given-names></name><name><surname>Chen</surname><given-names>S</given-names></name></person-group><article-title>A review on the electrochemical sensors and biosensors composed of nanowires as sensing material</article-title><source>Sensors</source><year>2008</year><volume>8</volume><fpage>290</fpage><lpage>313</lpage><pub-id pub-id-type="doi">10.3390/s8010290</pub-id></citation></ref>
<ref id="b97-sensors-11-05087"><label>97.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Li</surname><given-names>Q</given-names></name><name><surname>Kumar</surname><given-names>V</given-names></name><name><surname>Li</surname><given-names>Y</given-names></name><name><surname>Zhang</surname><given-names>H</given-names></name><name><surname>Marks</surname><given-names>TJ</given-names></name><name><surname>Chang</surname><given-names>RPH</given-names></name></person-group><article-title>Fabrication of ZnO nanorods and nanotubes in aqueous solutions</article-title><source>Chem. Mater</source><year>2005</year><volume>17</volume><fpage>1001</fpage><lpage>1006</lpage><pub-id pub-id-type="doi">10.1021/cm048144q</pub-id></citation></ref>
<ref id="b98-sensors-11-05087"><label>98.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lee</surname><given-names>SH</given-names></name><name><surname>Minegishi</surname><given-names>T</given-names></name><name><surname>Park</surname><given-names>JS</given-names></name><name><surname>Park</surname><given-names>SH</given-names></name><name><surname>Ha</surname><given-names>J-S</given-names></name><name><surname>Lee</surname><given-names>H-J</given-names></name><name><surname>Lee</surname><given-names>H-J</given-names></name><name><surname>Ahn</surname><given-names>S</given-names></name><name><surname>Kim</surname><given-names>J</given-names></name><name><surname>Jeon</surname><given-names>H</given-names></name><name><surname>Yao</surname><given-names>T</given-names></name></person-group><article-title>Ordered arrays of ZnO nanorods grown on periodically polarity-inverted surfaces</article-title><source>Nano Lett</source><year>2008</year><volume>8</volume><fpage>2419</fpage><lpage>2422</lpage><pub-id pub-id-type="doi">10.1021/nl801344s</pub-id><pub-id pub-id-type="pmid">18576694</pub-id></citation></ref>
<ref id="b99-sensors-11-05087"><label>99.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname><given-names>CH</given-names></name><name><surname>Wong</surname><given-names>AS</given-names></name><name><surname>Ho</surname><given-names>GW</given-names></name></person-group><article-title>Facile solution route to vertically aligned, selective growth of ZnO nanostructure arrays</article-title><source>Langmuir</source><year>2007</year><volume>23</volume><fpage>11960</fpage><lpage>11963</lpage><pub-id pub-id-type="doi">10.1021/la702296q</pub-id><pub-id pub-id-type="pmid">17941655</pub-id></citation></ref>
<ref id="b100-sensors-11-05087"><label>100.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Peulon</surname><given-names>S</given-names></name><name><surname>Lincot</surname><given-names>D</given-names></name></person-group><article-title>Mechanical study of cathodic electrodeposition of zinc oxide and zinc hydroxychloride flims from oxygenated aqueous zinc chloride solutions</article-title><source>J. Electrochem. Soc</source><year>1998</year><volume>145</volume><fpage>864</fpage><lpage>874</lpage><pub-id pub-id-type="doi">10.1149/1.1838359</pub-id></citation></ref>
<ref id="b101-sensors-11-05087"><label>101.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mastai</surname><given-names>Y</given-names></name><name><surname>Gal</surname><given-names>D</given-names></name><name><surname>Hodes</surname><given-names>G</given-names></name></person-group><article-title>Nanocrystal-size control of electrodeposited nanocrystalline semiconductor films by surface capping</article-title><source>J. Electrochem. Soc</source><year>2000</year><volume>147</volume><fpage>1435</fpage><lpage>1439</lpage><pub-id pub-id-type="doi">10.1149/1.1393373</pub-id></citation></ref>
<ref id="b102-sensors-11-05087"><label>102.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Pauporte</surname><given-names>T</given-names></name><name><surname>Bataillle Jouland</surname><given-names>L</given-names></name><name><surname>Vermersch</surname><given-names>FJ</given-names></name></person-group><article-title>Well aligned ZnO nanowire arrays prepared by seed layer free electrodeposition and their cassie wenzel transition after hydrophobization</article-title><source>J. Phys. Chem. C</source><year>2010</year><volume>114</volume><fpage>194</fpage><lpage>202</lpage><pub-id pub-id-type="doi">10.1021/jp9087145</pub-id></citation></ref>
<ref id="b103-sensors-11-05087"><label>103.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Choi</surname><given-names>A</given-names></name><name><surname>Kim</surname><given-names>K</given-names></name><name><surname>Jung</surname><given-names>H-I</given-names></name><name><surname>Lee</surname><given-names>SY</given-names></name></person-group><article-title>ZnO nanowire biosensors for detection of biomolecular interactions in enhancement mode</article-title><source>Sens. Actuat. B</source><year>2010</year><volume>148</volume><fpage>577</fpage><lpage>582</lpage><pub-id pub-id-type="doi">10.1016/j.snb.2010.04.049</pub-id></citation></ref>
<ref id="b104-sensors-11-05087"><label>104.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Corso</surname><given-names>CD</given-names></name><name><surname>Dickherber</surname><given-names>A</given-names></name><name><surname>Hunt</surname><given-names>WD</given-names></name></person-group><article-title>An investigation of antibody immobilization methods employing organosilanes on planar ZnO surfaces for biosensor applications</article-title><source>Biosens. Bioelectr</source><year>2008</year><volume>24</volume><fpage>805</fpage><lpage>811</lpage><pub-id pub-id-type="doi">10.1016/j.bios.2008.07.011</pub-id></citation></ref></ref-list>
<sec sec-type="display-objects">
<title>Figures</title>
<fig id="f1-sensors-11-05087" position="float">
<label>Figure 1.</label>
<caption>
<p>Micromolding process for fabricating polymer nanowires with high aspect ratio, <bold>(A)</bold> SEM image of Silicon master bearing square array posts grown using photolithography process, <bold>(B)</bold> Silicon master with liquid PDMS, treated with antisticking agent, <bold>(C)</bold> Cured PDMS peeling off from master, <bold>(D)</bold> Negative PDMS containing high aspect ratio hollows, <bold>(E)</bold> SEM image of hollow negative PDMS mould, <bold>(F)</bold> Polymer and liquid metal being cured in the mould, <bold>(G)</bold> Negative PDMS peeled off from actual polymer nanowire, <bold>(H)</bold> SEM image of nanostructured replica fabricated from epoxy resin (reprinted with permission from Wiley-VCH Verlag GmbH &amp; Co. KGaA) [<xref ref-type="bibr" rid="b33-sensors-11-05087">33</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f1.gif"/></fig>
<fig id="f2-sensors-11-05087" position="float">
<label>Figure 2.</label>
<caption>
<p>SEM images of polypyrrole nanowires grown using a three electrode system.</p></caption>
<graphic xlink:href="sensors-11-05087f2.gif"/></fig>
<fig id="f3-sensors-11-05087" position="float">
<label>Figure 3.</label>
<caption>
<p><bold>(A)</bold> Growth of nanowires using break junction method and <bold>(B)</bold> Graph showing the conductance of the polymernanowires during stretching process (reprinted with permission from the American Institute of Physics [<xref ref-type="bibr" rid="b39-sensors-11-05087">39</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f3.gif"/></fig>
<fig id="f4-sensors-11-05087" position="float">
<label>Figure 4.</label>
<caption>
<p>I–V characteristics of an aligned single polymer nanowire (reprinted with permission from Elsevier [<xref ref-type="bibr" rid="b44-sensors-11-05087">44</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f4.gif"/></fig>
<fig id="f5-sensors-11-05087" position="float">
<label>Figure 5.</label>
<caption>
<p>EDC cross linking showing <bold>(A)</bold> activation of carboxylic group in biomolecules and <bold>(B)</bold> activation of amine group in polypyrrole nanowires (reprinted with permission from the American Chemical Society [<xref ref-type="bibr" rid="b43-sensors-11-05087">43</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f5.gif"/></fig>
<fig id="f6-sensors-11-05087" position="float">
<label>Figure 6.</label>
<caption>
<p><bold>(A)</bold> Alignment of carbon nanotube at various voltages and <bold>(B)</bold> V-I characteristic of the aligned nanotubes (reprinted with permission from Elsevier [<xref ref-type="bibr" rid="b59-sensors-11-05087">59</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f6.gif"/></fig>
<fig id="f7-sensors-11-05087" position="float">
<label>Figure 7.</label>
<caption>
<p><bold>(A)</bold> Circuit model for single CNT deposition, <bold>(B)</bold> SEM image of CNT aligned using AC-DC electric field (reprinted with permission from Elsevier [<xref ref-type="bibr" rid="b61-sensors-11-05087">61</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f7.gif"/></fig>
<fig id="f8-sensors-11-05087" position="float">
<label>Figure 8.</label>
<caption>
<p><bold>(A) I</bold>–V characteristics measured during the immobilization of antibodies on to the CNTs and <bold>(B)</bold> Schematic representation of three electrode cell for selective binding of metal for ohmic contact along with the calibration curve for T-PSA based on electrochemical signal (reprinted with permission from John Wiley &amp; Sons [<xref ref-type="bibr" rid="b74-sensors-11-05087">74</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f8.gif"/></fig>
<fig id="f9-sensors-11-05087" position="float">
<label>Figure 9.</label>
<caption>
<p>SEM images and pictures showing the presence of antibodies due to immobilization (reprinted with permission from John Wiley &amp; Sons [<xref ref-type="bibr" rid="b69-sensors-11-05087">69</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f9.gif"/></fig>
<fig id="f10-sensors-11-05087" position="float">
<label>Figure 10.</label>
<caption>
<p>SEM image of ZnO nanorods grown on top of silicon substrate containing the seed layer (reprinted with permission from the American Chemical Society [<xref ref-type="bibr" rid="b97-sensors-11-05087">97</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f10.gif"/></fig>
<fig id="f11-sensors-11-05087" position="float">
<label>Figure 11</label>
<caption>
<p><bold>(a–f)</bold> Zinc oxide nanorods grown using deposition process at 90 degrees at different time periods (reprinted with permission from The American Chemical Society [<xref ref-type="bibr" rid="b94-sensors-11-05087">94</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f11.gif"/></fig>
<fig id="f12-sensors-11-05087" position="float">
<label>Figure 12.</label>
<caption>
<p><bold>(A)</bold> Microscopic image and <bold>(B)</bold> Fluorescent microscopic image of nanowires with biotin, <bold>(C)</bold> AFM image of GPS+Ab and <bold>(D)</bold> MTS+GMBS+Ab (reprinted with permission from Elsevier [<xref ref-type="bibr" rid="b103-sensors-11-05087">103</xref>,<xref ref-type="bibr" rid="b104-sensors-11-05087">104</xref>]).</p></caption>
<graphic xlink:href="sensors-11-05087f12.gif"/></fig></sec></back></article>