Article

Myocardial Motion Analysis for Determination of Tei-Index of Human Heart

1
College of Computer Science, Zhejiang University of Technology, 310023 Hangzhou, China
2
Department of Informatics, University of Hamburg, 22527 Hamburg, Germany
*
Authors to whom correspondence should be addressed.
Sensors 2010, 10(12), 11428-11439; https://doi.org/10.3390/s101211428
Submission received: 4 November 2010 / Revised: 24 November 2010 / Accepted: 8 December 2010 / Published: 13 December 2010
(This article belongs to the Special Issue Sensors in Biomechanics and Biomedicine)

Abstract

: The Tei index, an important indicator of heart function, lacks a direct method to compute because it is difficult to directly evaluate the isovolumic contraction time (ICT) and isovolumic relaxation time (IRT) from which the Tei index can be obtained. In this paper, based on the proposed method of accurately measuring the cardiac cycle physical phase, a direct method of calculating the Tei index is presented. The experiments based on real heart medical images show the effectiveness of this method. Moreover, a new method of calculating left ventricular wall motion amplitude is proposed and the experiments show its satisfactory performance.

Graphical Abstract

1. Introduction

Cardiovascular diseases have become the top factor causing human death in both western and eastern world. People hope that these diseases can be traced before they onset. A simple, reproducible, non-invasive test for determinants of prognosis is therefore necessary. For this kind of test, doctors need to observe the current status of hearts and have some effective measurement rules to decide if hearts is normal or not. For non-invasive check methods, there are several heart medical imaging technologies, such as MR, CT, SPECT and Ultrasound, widely used for heart diseases diagnosis, from which doctors can observe patients heart status without invasion.

Myocardial motion that is directly related to cardiac vascular supply is widely studied based on heart medical images to analyze the heart condition, especially the left ventricular function, for diagnosing heart abnormalities [13]. Left ventricular (LV) is the most important part of heart and LV function is generally analyzed to diagnose the heart condition. Traditionally, LV systolic function is used as measurement of the heart condition. However, LV diastolic function is also an important indicator of the heart condition. Both of them are important determinants of prognosis. A clinical assessment of using both LV systolic and diastolic function will be better than using only one of them. The Tei index [4], raised originally by Tei in 1995, can be used to assess both LV systolic and diastolic function at the same time and consequently becomes an important indicator of heart condition [5,6]. In [7], several literatures had been reviewed in which the Tei index had been proved to be used to diagnose many cardiovascular diseases. The Tei index can be used to assess either left or right ventricular function, calculated as the sum of the isovolumic contraction time (ICT) and isovolumic relaxation time (IRT) divided by ejection time (ET). The ICT and IRT, however, are very difficult to calculate because of the lack of the whole deform information of LV. The Tei index is therefore generally measured by indirect methods (e.g., [8,9]. The originally method to evaluate the time intervals is through pulsed-wave Doppler velocity spectra of ventricular inflow and outflow [4]. However, there is possible error source because of the inability to acquire inflow and outflow velocity spectra during the same cardiac cycle [5]. The tissue Doppler imaging is employed to measure the time intervals for computing the Tei index to avoid this kind of potential error [9]. Another method using left ventricular area waveforms with acoustic quantification is also introduced to calculate the Tei index for avoiding the potential error. However, both of them are also the indirect methods.

In the myocardial motion analysis, the cardiac cycle is a complicated time-varying process and is generally partitioned into several phases based on time to simplify the process. According to clinical diagnosis, however, the phase should be definitely based on LV deformation and stress since the dynamics of heart is caused by that deformation. This definition is called cardiac physical phase. In this paper, a method of cardiac cycle physical phase (CPP) division according to the LV anatomy is proposed first based on B-spline represented heart model, of which the initial work [10] has been presented in Robio 2010. By using the proposed method, the CPP can be accurately partitioned. Based on accurately CPP partitions, a direct method to accurately measure the Tei index is then presented by computing the ICT and IRT from CPP. To our knowledge, it is the first direct calculation of the Tei index in literatures. In particular, the SPECT heart images are used in this study. As a kind of new application of heart medical images, the proposed calculation of the Tei index is proved better than traditional assessment methods.

Moreover, LV wall motion amplitude (LVMA) can also be computed to analyze the LV wall movement based on the accurate CPP partitions in this study. The movement of LV wall is another very important index of the LV function [11,12]. It reflects the deformation capability of LV. Traditionally, the analysis of LV wall movement is focused on myocardial velocities [13,14]. The LVMA, however, can indicate directly the abnormal area of LV wall when there is heart disease [15]. Through LVMA, the ill area of heart with abnormal amplitude could be detected and localized, which will of course improve the effect of diagnosis.

The organization of this paper is as follows. In the next section, the matrix representation of B-spline is introduced and the volumetric measurement of B-spline is given. The method of CPP partition and calculation of Tei and LVMA are explained in Section 3. The proposed methods are evaluated by experiments on a real human data in Section 4 and the results are also analyzed.

2. Shape Representation for Volumetric Measurement

2.1. Matrix representation of B-spline

A B-spline curve consists of segments, with each segment of degree k constructed by k+1 sequential control points. Let t = (uui)/(ui+1ui), the segment has the following matrix form [16,17] in the nonempty interval [ui,ui+1]:

p i ( t ) = [ 1 t t 2 t k ] M i k + 1 [ V i k V i k + 1 V i ] T
where t ∈ [0,1] and V is the vector of k+1 control points. The number of control points are denoted as i = k,k+1, ⋯,n+1 and the ith basis matrix, M i k + 1, is the matrix form of B-spline basis in order k.

The whole curve can thus be represented as:

P ( t ) = i = k n p i ( t ) = i = k n j = 0 k a i ( j ) t j = i = k n j = 0 k ( l = 0 k M i k + 1 ( j , l ) V i k + l ) t j
where
a i ( j ) = l = 0 k M i k + 1 ( j , l ) V i k + l

Equally, a part of the B-spline surface in the nonempty area [ui,ui+1) × [vi,vi+1) can be represented as:

s i , j ( t , w ) = T k 1 M i , u k 1 + 1 V i , j h ( M j , v k 2 + 1 ) T W k 2 T
where Tk1 = [1 t t2tk1] and W k 2 T = [ 1 w w 2 w k 2 ] T with t = (uui)/(ui+1ui) and w = (vvi)/(vi+1vi), where u,v ∈ [ui,ui+1) × [vi,vi+1). M i , u k 1 + 1 and M j , v k 2 + 1 are the ith and jth basis matrixes in [ui,ui+1) and [vi,vi+1), respectively.

The whole surface is then represented as follow:

X ( t , w ) = i = k 1 m j = k 2 n l = 0 k 2 r = 0 k 1 B i , j x ( r , l ) t r w l Y ( t , w ) = i = k 1 m j = k 2 n l = 0 k 2 r = 0 k 1 B i , j y ( r , l ) t r w l Z ( t , w ) = i = k 1 m j = k 2 n l = 0 k 2 r = 0 k 1 B i , j z ( r , l ) t r w l

2.2. Volumetric measurement

The volume can be expressed as [18]:

V = z 1 z 2 A ( Z ) d z
where A(z) is the area of the slice at depth z.

As the equations given by Equation 1 to Equation 4, let S ( t , w ) t and S ( t , w ) w denote the derivatives of S(u,v) with respect to t and w.

The computation of the area of a slice at depth z is:

A ( z ( w ) ) = j = k 2 n 0 1 Y ( t , w ) × X ( t , w ) t d t
where Y(t,w) is given by Equation 6, and X ( t , w ) t is the derivative with respect to t and Z ( t , w ) w is the derivative with respect to w.

The volume of B-spline surface of orders k1 × k2 is:

V = i = k 1 m j = k 2 n ( l 1 = 1 ( 3 × k 2 1 ) l 2 = 1 ( 3 × k 1 1 ) C i , j ( l 1 , l 2 ) × 1 l 2 + 1 × 1 l 1 + 1 )
where Ci, j is the matrix of size 3k1 × 3k2 which is the product of the three polynomials Y(t,w).

3. CPP Partition

3.1. CPP Partition

Cardiac cycle is a very complicated physical process. Traditional researches used to divide the cycle into two major parts as systole and diastole. During systole, LV contracts thus the blood in LV can be ejected out. On the opposite, during diastole LV bulges and imbibes blood in. The function of heart is achieved by the repeatedly alternating systole and diastole. As the LV motion is not uniform neither in systole nor in diastole, this rough partition can hardly express the true feature of LV motion. In fact it is shown by anatomy knowledge that the whole cardiac cycle contains 7 CPPs based on different LV shape and function. These CPPs are Isovolumic Systolic (IS), Rapid Ejection Period (REP), Slow Down Ejection Period (SDEP), Isovolumic Relaxation Period (IRP), Rapid Filling Period (RFP), Slow Down Filling Period (SDFP) and Atrial Systole (AS) [19] where IS, REP and SDEP compose the systole and IPR, RFP, SDFP belong to the diastole.

The shape of LV shows various features in different CPP, and the changing of these shapes is the main basis of CPP partition. To divide the CPP phases, two shape factors are necessary. The first shape factor is the volume of LV (LVV). Assume that the LVV curve during whole cardiac cycle is already known and denoted with C(t). It is easy to understand that during the whole systole C(t) keeps decreasing, while in diastole it keeps increasing. Let curve C′(t) denote derivative of C(t). According to medical knowledge, the features of C(t) and C′(t) in each CPP can be listed as in the columns 3–4 of Table 1. During the IS, IRP and AS phases, the values of C(t) remain almost invariant and consequently its derivative is approximate to zero. During the REP and SDEP phases, the values of C(t) keep on reducing and C′(t) is of course negative. During the RFP and SDFP phases, the values of C(t) keep on increasing and C′(t) is positive. The IS and AS, REP and SDEP, RFP and SDFP, however, are the adjacent phases, therefore it is difficult to separate them.

Fortunately, there is another shape factor, called LV long-axis length (LVLL), that can provide the complement information. LVLL is defined as the height from the base to the apical of LV. Assuming the LVLL curve is L(t), and its derivative is L′(t). According to the anatomy priori knowledge the L(t) and L′(t) features in each CPP are listed in the columns 5–6 of Table 1. During IS and SDFP phases, L(t) keeps on decreasing and L′(t) is negative. During SDEP phase, L(t) keeps on increasing and L′(t) is positive. By compounding the shape factors, LVV and LVLL, it is now easy to divide the seven phases of cardiac cycle. Figure 2 illustrate examples of C′(t) and L′(t).

3.2. Determination of Tei index

In the beginning of systole and diastole, the shape of LV sharply changes while the LVV stays invariant. These periods are called isovolumetric contraction (IC) and isovolumetric relaxation (IR). Medical research shows that the biggest stress and displacement of LV occur in these two periods. When some diseases occur, the LV would need longer time to achieve the deformation and displacement, thus the length of IC and IR are very important index for evaluating LV functions. Based on that Tei-index is raised by Japanese researcher Tei in 1995 [4]. The definition of Tei is:

Tei index = t I C + t I R t E

Tei index is also called myocardial performance index (MPI). This new index can generally evaluate the heart function in both diastole and systole. It has been widely used in heart disease diagnosis. Based on the CPP partition, a direct method of calculating Tei index can be deduced.

IC and IR are the periods while the LV shape changes largely and LVV keeps almost invariant. According to the CPP characters listed in Table 1, it is obvious that IC is equal to IS and IR is equal to IRP. The ET is the length of systole which equals to the sum of IS, REP and SDEP.

The Tei index can therefore be calculated as:

Tei index = t I S + t I R T t I S + t P R E + t S D E P
where the tx is the length of time intervals of the corresponding CPP with x (x = IS, IRT, PRE, and SDEP). This equation is totally based on the partitions of CPP. Due to the accurate CPP partitions, the precise and direct calculation of Tei index can obtained.

3.3. Myocardial Motion

The function of LV is achieved by cycle motion of LV wall. The motion amplitude of LV wall (LVMA) reflect the deformation capability of LV. When some disease occurs, there must be some abnormalities of the LVMA on the sick area, thus LVMA can be used as an important parameter for LV function analysis. Azhari et al. [15] have used LVMA in the detection of dysfunctional myocardium.

It is also known that the movement of LV wall is not in a uniform speed, thus the distribution of LVMA differs largely in different CPPs. For example, the LVMA in the beginning of systole and diastole are much larger than it in other time because the main deformation of LV happens in these periods. Due to these causes mentioned above, to study on the LVMA in different CPP is highly necessary.

Assuming that the point p is on the wall of LV. By tracking the position of p at each time interval t, if the time of the whole cardiac cycle is mt, a position matrix can be obtained T = [p(t) p(2t) ⋯ p(mt)](p(t) = [xt yt zt]T). Fitting each row in T with three B-spline curves Mx(t), My(t) and Mz(t) which stand for the trajectory of p in x, y and z axis during the whole cardiac cycle will be obtained. Through the trajectory curve of p, it is very simple to calculate the displacement of p in an arbitrary period [t1, t2] (0 ≤ t1 < t2mt) by:

D 1 , 2 = ( M x ( t 2 ) M x ( t 1 ) ) 2 + M y ( t 2 ) M y ( t 1 ) ) 2 + M z ( t 2 ) M z ( t 1 ) ) 2

In order to get the displacement of whole LV wall, a large amount of points should be marked and tracked. Assuming such a points set P = [p1, p2, ⋯, pn] and their position matrix T are known, through Equation 11 the D1,2 of each point in P can be calculated. The displacement vector is D = [ D 1 , 2 1 , D 1 , 2 2 , , D 1 , 2 n ], where D 1 , 2 i means the displacement of ith point in P.

As an elastomer, the motion of LV is continuous and gradually variational so that the displacement of the whole LV wall can be described as a surface. Using the position information of P(t1) (position of all points in P at t1) and D a B-spline surface can be fitted. This surface is the displacement of whole LV wall in period [t1, t2] and be denoted by Df (t1, t2).

In Section 1 the cardiac cycle is divided into 7 CPPs (i.e., IS, REP, SDEP, IRP, RFP, SDFP, AS). The beginning and ending time of each CPP is tbname and tename. Then the LVMA of each CPP can be calculated by Df (tbname, tename).

4. Experiments

4.1. LV B-spline Model

The 3D heart model is built by the Active Shape Models (ASM) [20] which has been extended to 3D representation in our previous work. By manually labeled landmarks which form the point distribution model in training images according to the rules described in [20], the ASM can learn the variations of heart shapes. The model can then be used to segment and fit a new heart in a set of new images. Note that the model is represented by a point set. After a new 3D heart is fitted by the model, those points of this heart model are used as the control points from which the B-spline heart model can be built according to Equation 1 to Equation 5.

Our experiment is focused on the left ventricle, about 1000 points have been tracked, and about 400 points are distributing on inside-wall while rests are on outside-wall. These points constitute the whole motion of left ventricle in a cardiac cycle, and the points are labeled in several phases, with 0.1 second apart from each other. In the model we focus on the inside-wall surface since the LVV and LVLL is majorly decided by it. Figure 1 shows one of the point model.

4.2. LVV and LVL curve interpolation

After the models in all phases are built, the LVV in each moments can be calculated by Equation 1. These LVV values are vi where i = 1,2, ⋯,7. Using the set of vi to interpolate with B-spline method then a LVV curve C(t) is fitted. The derivative C′(t) can also be calculated. The curve with solid line in Figure 2 is an example of the C′(t) curve. The landmarks of right Y-axis is corresponding to this curve.

In each inside-wall surface model, finding the centers at top and bottom layer, the LVLL can be calculated by the distance of these two centers. Assuming that the LVLL values are obtained from m model, li where i = 1,2, ⋯, m, a B-spline curve L(t) can be fitted with li and the derivative curve L′(t) can also be calculated. The curve with dash line in Figure 2 is an example of the L′(t) curve. The landmarks of left Y-axis is corresponding to this curve.

4.3. Measurement of CPP and Tei-index

With the curves of C′(t) and L′(t), the partition of CPP can be done by following steps.

  • Step 1: find the zero-points in C′(t) as the boundary of systolic and diastolic (blue line in Figure 3);

  • Step 2: find the zero-points in L′(t), to do the further division of CPP(green line in Figure 3).

The final CPP partition result is shown in Figure 3, and the lasting time of each CPP is calculated too. The comparison of the result to the medical statistical average data decided by experts is shown in Table 2 . Obviously the experiment result is very close to the average data which can prove the validity of this partition.

The Tei index can be calculated by Equation 10. In this experiment the value of Tei is 0.3617 while the common range of Tei is 0.39±0.05 by medical statistics.

The distribution of LVMA in 6 CPPs is shown in Figure 4 (AS is neglected because in that phase the deformation of LV is inconspicuous). It can be seen that the LVMA of LV apical is much larger than that of LV base. During the systole LVMA concentrates in the back of LV while do the opposite during diastolic period. The largest LVMA occurs in IS and IRP which are the beginning of systole and diastole respectively. The result agrees with the medical statistical rule and is very closed to the result of other research [21,22].

5. Conclusions

In this paper, a new perspective of myocardial motion analysis, accurate division of cardiac cycle physical phases (CPP), is proposed. Based on this method, an precise and direct calculation of the Tei index is presented. First, several B-spline models of LV inside-wall are built at different time phases. Second, the LVV and LVLL of each model are calculated by B-spline integral and the curves of these two factors are fitted in whole cardiac cycle. Third, the derivative curves of LVV and LVLL are calculated. At last, the CPP partition by finding zero points in them is obtained. The experiment with real human LV data shows the result of this method is very close to the medical statistical values. Tei index is a new heart function index which strongly depends on the CPP. With the accurate CPP division, the accuracy of the direct Tei index calculation method is shown by the experiment result. This paper also proposed a new method to computing LVMA to analyze the myocardial motion. The color figure of LVMA in different CPP shows rules of myocardial motion which are very close to the results of other researches.

Acknowledgments

This work was supported by the National Natural Science Foundation of China and Microsoft Research Asia (60870002, 60802087), NCET, and the Science and Technology Department of Zhejiang Province (2010R10006, 2010C33095, Y1090592).

References

  1. Shling, M; Arigovindan, M; Jansen, C; Hunziker, P; Unser, M. Myocardial Motion Analysis From B-Mode Echocardiograms. IEEE Trans Image Process 2005, 14, 525–536. [Google Scholar]
  2. Wang, X; Metaxas, D; Chen, T; Axel, L. Meshless deformable models for LV motion analysis. Proceedings of IEEE Conference on Computer Vision and Pattern Recognition, Anchorage, AK, USA, June 2008; pp. 1–8.
  3. Sundar, H; Litt, H; Shen, D. Estimating myocardial motion by 4D image warping. Pattern Recognit 2009, 42, 2514–2526. [Google Scholar]
  4. Tei, C. New Noninvasive Index for Combined Systolic and Diastolic Ventricular Function. J Cardiol 1995, 26, 135–136. [Google Scholar]
  5. Pellett, AA; Tolar, WG; Merwin, DG; Kerut, EK. The Tei Index: Methodology and Disease State Values. Echocardiography 2004, 21, 669–672. [Google Scholar]
  6. Sutton, MSJ; Wiegers, SE. The Tei index—a role in the diagnosis of heart failure. Eur Heart J 2000, 21, 1888–1895. [Google Scholar]
  7. Lakoumentas, JA; Panou, FK; Kotseroglou, VK; Aggeli, KI; Harbis, PK. The Tei Index of Myocardial Performance: Applications in Cardiology. Hellenic J Cardiol 2005, 46, 52–58. [Google Scholar]
  8. Masugata, H; Senda, S; Goda, F; Yamagami, A; Okuyama, H; Kohno, T; Hosomi, N; Yukiiri, K; Noma, T; Murao, K; Nishiyama, A; Kohno, M. Independent Determinants of the Tei Index in Hypertensive Patients With Preserved Left Ventricular Systolic Function. Int Heart J 2009, 50, 331–340. [Google Scholar]
  9. Comas, M; Crispi, F; Cruz-Martinez, R; Martinez, JM; Figueras, F; Gratacs, E. Usefulness of myocardial tissue Doppler vs conventional echocardiography in the evaluation of cardiac dysfunction in early-onset intrauterine growth restriction. Am J Obstet Gynecol 2010, 203, 45.e1–45.e7. [Google Scholar]
  10. Guan, Q; Du, Y; Chen, SY; Wang, F. Calculation of Tei Index and LV Motion Amplitude Based on Cardiac Physical Phase. Proceedings of IEEE International Conference on Robotics and Biomimetics, Guilin, China, December 2009; pp. 1027–1031.
  11. Greenberg, NL; Popovic, ZB; Saracino, G; Grimm, RA; Thomas, JD. Novel time-varying 3D display of wall motion, strain, strain rate and torsion for LV function assessment. Proceedings of Computers in Cardiology, Bologna, Italy, September 2008, 21–23.
  12. Nichols, KJ; van Tosh, A; Wang, Y; Reichek, N; Palestro, CJ. Automated versus manual detection of left ventricular wall motion abnormalities by gated blood pool SPECT. Med Phys 2009, 36, 1251–1257. [Google Scholar]
  13. Mark, M; Schneider, B; Hennig, J. Fast phase contrast cardiac magnetic resonance imaging: Improved assessment and analysis of left ventricular wall motion. J Magn Reson Imaging 2002, 15, 642–653. [Google Scholar]
  14. Oki, T; Iuchi, A; Tabata, T; Mishiro, Y; Yamada, H; Abe, M; Onose, Y; Wakatsuki, T; Ito, S. Left Ventricular Systolic Wall Motion Velocities Along the Long and Short Axes Measured by Pulsed Tissue Doppler Imaging in Patients with Atrial Fibrillation. J Am Soc Echocardiogr 1999, 12, 121–128. [Google Scholar]
  15. Azhari, H; Sideman, S; Weiss, JL; Shapiro, EP; Weisfeldt, ML; Graves, WL; Rogers, WJ; Beyar, R. Three-dimensional Mapping of Acute Ischemic Regions Using MRI: Wall Thickening Versus Motion Analysis. Am J Physiol 1990, 259, H1492–H1503. [Google Scholar]
  16. Qin, K. General Matrix Representations for B-Splines and Applications. Proceedings of the Sixth Pacific Conference on Computer Graphics and Applications, Singapore, October 1998; pp. 37–43.
  17. Wang, X; Sun, J; Qin, K. Symbolic Matrix Representation of NURBS and Its Application. Chin J Comput 1993, 16, 29–34. [Google Scholar]
  18. Jiang, TT; Chen, SY. 3-D representation and volumetric measurement of human heart from a cylindrical B-Spline surface model. Proceedings of The International Conference on BioMedical Engineering and Informatics, Sanya, China, May 2008; pp. 765–769.
  19. Mirsky, I. Assessment of passive elastic stiffiness of cardiac muscle: Mathematical concepts, physiologic and clinical considerations, directions of future research. Prog Cardiologic Dis 1976, 17, 277–281. [Google Scholar]
  20. Cootes, TF; Taylor, CJ; Cooper, DH; Graham, J. Active shape models — their training and application. Comput Vis Image Understand 1995, 61, 38–59. [Google Scholar]
  21. Jinah, P; Metaxas, D; Young, AA; Axel, L. Deformation models with parameter functions for cardiac motion analysis from tagged MRI data. IEEE Med Image 1996, 15, 278–289. [Google Scholar]
  22. Maroko, PR. Modification of myocardial infarction size after coronary occlusion. Ann Int Med 1973, 79, 720–733. [Google Scholar]
Figure 1. An example of the LV endocardium point model at one time phase.
Figure 1. An example of the LV endocardium point model at one time phase.
Sensors 10 11428f1 1024
Figure 2. LVV varying cure (solid line) and LVLL varying cure (dash line) in whole cardiac cycle.
Figure 2. LVV varying cure (solid line) and LVLL varying cure (dash line) in whole cardiac cycle.
Sensors 10 11428f2 1024
Figure 3. CPP partition in cardiac cycle.
Figure 3. CPP partition in cardiac cycle.
Sensors 10 11428f3 1024
Figure 4. LVMA color graph of 6 CPPs. The color band in left column indicates the value of LVMA.
Figure 4. LVMA color graph of 6 CPPs. The color band in left column indicates the value of LVMA.
Sensors 10 11428f4 1024
Table 1. LVV and LVLL Features of Each CPP.
Table 1. LVV and LVLL Features of Each CPP.
CPPLVV (C(t))C′(t)LV LL(L(t))L′(t)
SystolicISHold on 0Reduce< 0
REPReduce< 0Reduce< 0
SDEPReduce< 0Increase> 0
DiastolicIRPHold on 0Increase> 0
RFPIncrease> 0Increase> 0
SDFPIncrease> 0Reduce< 0
ASHold on 0Hold on 0
Table 2. CPP Lasting Time.
Table 2. CPP Lasting Time.
PhaseAverage dataResult
IS0.06–0.080.066
PRE0.110.128
SDEP0.140.132
IRP0.06–0.080.057
RFP0.110.047
SDFP0.120.151
AS0.10.119

Share and Cite

MDPI and ACS Style

Chen, S.; Zhang, J.; Zhang, H.; Guan, Q.; Du, Y.; Yao, C.; Zhang, J. Myocardial Motion Analysis for Determination of Tei-Index of Human Heart. Sensors 2010, 10, 11428-11439. https://doi.org/10.3390/s101211428

AMA Style

Chen S, Zhang J, Zhang H, Guan Q, Du Y, Yao C, Zhang J. Myocardial Motion Analysis for Determination of Tei-Index of Human Heart. Sensors. 2010; 10(12):11428-11439. https://doi.org/10.3390/s101211428

Chicago/Turabian Style

Chen, Shengyong, Jianhua Zhang, Houxiang Zhang, Qiu Guan, Yahui Du, Chunyan Yao, and Jianwei Zhang. 2010. "Myocardial Motion Analysis for Determination of Tei-Index of Human Heart" Sensors 10, no. 12: 11428-11439. https://doi.org/10.3390/s101211428

Article Metrics

Back to TopTop